首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
A method for simultaneous determination of 5-hydroxy-N-methyl-2-pyrrolidone (5-HNMP) and 2-hydroxy-N-methylsuccinimide (2-HMSI) was developed. These compounds are metabolites from N-methyl-2-pyrrolidone (NMP), a powerful and widely used organic solvent. 5-HNMP and 2-HMSI were purified from plasma and urine by solid-phase extraction using Isolute ENV+ columns, and analysed by liquid chromatography coupled to a mass spectrometer fitted with an atmospheric pressure turbo ion spray ionisation interface in the positive ion mode. The method was validated for plasma and urine concentrations from 0.12 to 25 microg/ml. The recoveries for 5-HNMP and 2-HMSI in plasma were 99 and 98%, respectively, and in urine 111 and 106%, respectively. For 5-HNMP and 2-HMSI, the within-day precision in plasma was 1-4 and 3-6%, respectively, and in urine 2-12 and 3-10%, respectively. The corresponding data for the between-day precision was 5 and 3-6%, respectively, and 4-6 and 7-8%, respectively. The detection limit for 5-HNMP was 4 ng/ml in plasma and 120 ng/ml in urine. For 2-HMSI, it was 5 ng/ml in plasma and 85 ng/ml in urine. The method is applicable for analysis of plasma and urine samples from workers exposed to NMP.  相似文献   

2.
Sensitive high-performance liquid chromatographic assays have been developed for the quantification of stavudine (2',3'-didehydro-3'-deoxythymidine, d4T) in human plasma and urine. The methods are linear over the concentration ranges 0.025-25 and 2-150 microg/ml in plasma and urine, respectively. An aliquot of 200 microl of plasma was extracted with solid-phase extraction using Oasis cartridges, while urine samples were simply diluted 1/100 with HPLC water. The analytical column, mobile phase, instrumentation and chromatographic conditions are the same for both methods. The methods have been validated separately, and stability tests under various conditions have been performed. The detection limit is 12 ng/ml in plasma for a sample size of 200 microl. The bioanalytical assay has been used in a pharmacokinetic study of pregnant women and their newborns.  相似文献   

3.
Olanzapine is a commonly used atypical antipsychotic medication for which therapeutic drug monitoring has been proposed as clinically useful. A sensitive method was developed for the determination of olanzapine concentrations in plasma and urine by high-performance liquid chromatography with low-wavelength ultraviolet absorption detection (214 nm). A single-step liquid-liquid extraction procedure using heptane-iso-amyl alcohol (97.5:2.5 v/v) was employed to recover olanzapine and the internal standard (a 2-ethylated olanzapine derivative) from the biological matrices which were adjusted to pH 10 with 1 M carbonate buffer. Detector response was linear from 1-5000 ng (r2>0.98). The limit of detection of the assay (signal:noise=3:1) and the lower limit of quantitation were 0.75 ng and 1 ng/ml of olanzapine, respectively. Interday variation for olanzapine 50 ng/ml in plasma and urine was 5.2% and 7.1% (n=5), respectively, and 9.5 and 12.3% at 1 ng/ml (n=5). Intraday variation for olanzapine 50 ng/ml in plasma and urine was 8.1% and 9.6% (n=15), respectively, and 14.2 and 17.1% at 1 ng/ml (n=15). The recoveries of olanzapine (50 ng/ml) and the internal standard were 83 +/- 6 and 92 +/- 6% in plasma, respectively, and 79 +/- 7 and 89 +/- 7% in urine, respectively. Accuracy was 96% and 93% at 50 and 1 ng/ml, respectively. The applicability of the assay was demonstrated by determining plasma concentrations of olanzapine in a healthy male volunteer for 48 h following a single oral dose of 5 mg olanzapine. This method is suitable for studying olanzapine disposition in single or multiple-dose pharmacokinetic studies.  相似文献   

4.
An LC-MS-MS method and an HPLC-UV method have been developed for the assay of a novel thrombin inhibitor in human fluids. The LC-MS-MS method is developed for plasma, which usually requires maximum sensitivity. The HPLC-UV method is for urine. In both methods, analytes are extracted using liquid-liquid extraction, and analyzed by reversed-phase high-performance liquid chromatography. A tandem mass spectrometer in the multiple reaction monitoring (MRM) mode is used for detection of the analytes in the plasma method. UV is the detector for the urine method. The plasma method has a lower limit of quantitation (LOQ) of 0.1 ng/ml with a linearity range of 0.1-100 ng/ml. The urine method has an LOQ of 8.12 ng/ml (20 nM) and the linear dynamic range is 8.12-8120 ng/ml (20-20000 nM). Both methods are fast, specific and sensitive. Various validation procedures have proven that both methods are rugged, robust and reproducible. The research also suggested that, while LC-MS-MS provides superior sensitivity and selectivity for the determination of drugs and their metabolites at very low concentrations, HPLC with a conventional detector such as UV is still useful in the analysis when the sensitivity requirement is not crucial.  相似文献   

5.
A capillary zone electrophoretic method for the quantification of (E)-5-(2-bromovinyl)-2'-deoxyuridine in plasma has been developed and validated. Separation was performed with a 25 mmol/l borate buffer, pH 9.0, after an initial rinsing step with sodium hydroxide. The rinsing step was necessary for reproducible analyses of aqueous samples and plasma extracts obtained by C18 solid-phase extraction after deproteination with perchloric acid. No interferences with plasma compounds were observed. The calibration graph was linear over the range of 30 to 3000 ng/ml using 5-fluorouracil as external standard. The limit of quantification was 24 ng/ml. The CZE method is fast, reproducible, linear and is therefore a good alternative for the already established HPLC methods.  相似文献   

6.
A high-performance liquid chromatographic method for the determination of a novel calmodulin antagonist, 3-[2-[4-(3-chloro-2-methylphenyl)-1-piperazinyl]ethyl]-5,6-dimethoxy-1-( 4-imidazolylmethyl)-1H-indazole dihydrochloride 3.5 hydrate, DY-9760e and its major metabolite, 3-[2-[4-(3-chloro-2-methylphenyl)-1-piperazinyl]ethyl]-5,6-dimethoxyi ndazole, DY-9836 in human plasma has been developed. DY-9760e, DY-9836 and the internal standard (I.S.) were extracted from plasma by means of an Isolute C18 (EC) column. The extracts were chromatographed on a reversed-phase TSK-gel ODS-80Ts column using 0.1 M acetate buffer (pH 5)-CH3CN (65:35, v/v) as the mobile phase at a flow-rate of 1.0 ml/min. Fluorescence detection at an excitation wavelength of 303 nm and an emission wavelength of 347 nm resulted in a limit of quantitation of 1.000 ng/ml for plasma. The method showed satisfactory sensitivity, precision, accuracy, recovery and selectivity. Stability studies showed that DY-9760 and DY-9836 were stable in plasma up to at least eight weeks at -80 degrees C.  相似文献   

7.
A bioanalytical method for the determination of the anticancer drug chlorambucil (Leukeran) and its phenyl acetic acid mustard metabolite in human serum and plasma is described. Automated solid-phase extraction of the analytes is carried out with C18 sorbent packed in a 96 well format microtitre plate using a robotic sample processor. The extracts are analysed by isocratic reversed-phase liquid chromatography using pneumatically and thermally assisted electrospray ionisation (TurboIonspray) with selected reaction monitoring. The method is specific and sensitive, with a range of 4-800 ng/ml in human serum and plasma for both parent drug and metabolite (sample volume 200 microl). The method is accurate and precise with intra-assay and inter-assay precision (C.V.) of <15% and bias <15% for both analytes. The automated extraction procedure is significantly faster than manual sample pre-treatment methods, a batch of 96 samples is extracted in 50 min allowing for faster sample turnaround. The method has been used to provide pharmacokinetic support to biocomparability studies of Leukeran following single doses of oral tablet formulations.  相似文献   

8.
This paper describes a high-performance liquid chromatographic method for the assay of quinfamide and its main metabolite, 1-(dichloroacetyl)-1,2,3,4,-tetrahydro-6-quinolinol, in plasma, urine and feces. It requires 1 ml of biological fluid, an extraction using Sep-Pack cartridges and acetonitrile for drug elution. Analysis was performed on a CN column (5 microm) using water-acetonitrile-methanol (40:50:10) as a mobile phase at 269 nm. Results showed that the assay was linear in the range between 0.08 and 2.0 microg/ml. The limit of quantitation was 0.08 microg/ml. Maximum assay coefficient of variation was 14%. Recovery obtained in plasma, urine and feces ranged from 82% to 98%.  相似文献   

9.
A rapid, sensitive and selective method has been developed for the quantification of plasma concentrations of neuromuscular blocking drug, rocuronium, using gas chromatography with mass spectrometric detection. 3-Desacetylvecuronium served as the internal standard. The method involved iodide ion pair formation and a single-step liquid-liquid extraction with dicholoromethane. This method also permits simultaneous determination of its putative metabolite, 17-desacetylrocuronium, although the high detection limit for the metabolite limits the practical application of this method in pharmacokinetic study of the metabolite. The extraction efficiency was approximately 75% for rocuronium and approximately 50% for 17-desacetylrocuronium. The limit of quantification was 26 ng/ml for rocuronium and 870 ng/ml for its metabolite. The assay was used successfully in a patient undergoing liver transplantation and receiving rocuronium as a constant rate infusion and in a patient undergoing general elective surgery receiving the drug as an intravenous bolus. This assay is a time-saving alternative to published gas or liquid chromatographic methods for assaying rocuronium.  相似文献   

10.
A sensitive high-performance liquid chromatographic assay has been developed for measuring plasma concentrations of methotrexate and its major metabolite, 7-hydroxymethotrexate. Methotrexate and metabolite were extracted from plasma using solid-phase extraction. An internal standard, aminopterin was used. Chromatographic separation was achieved using a 15-cm poly(styrene-divinylbenzene) (PRP-1) column. This column is more robust than a silica-based stationary phase. Post column, the eluent was irradiated with UV light, producing fluorescent photolytic degradation products of methotrexate and the metabolite. The excitation and emission wavelengths of fluorescence detection were at 350 and 435 nm, respectively. The mobile phase consisted of 0.1 M phosphate buffer (pH 6.5), with 6% N,N-dimethylformamide and 0.2% of 30% hydrogen peroxide. The absolute recoveries for methotrexate and 7-hydroxymethotrexate were greater than 86%. Precision, expressed as a coefficient of variation (n=6), was <10% at each of five methotrexate concentrations in the range 2.5-50 ng/ml. The limits of quantitation of methotrexate were 1 and 2.5 ng/ml for methotrexate and 7-hydroxymethotrexate, respectively (using 1 ml plasma). A robust HPLC method has been developed for the reproducible quantitation of methotrexate in plasma of patients taking a weekly dose of methotrexate for rheumatoid arthritis.  相似文献   

11.
Sensitive and specific monoclonal radioimmunoassays (RIA) for pirenzepine, a muscarinic receptor (M1) antagonist, were developed and validated for rapid automated routine analysis of plasma and urine samples from clinical studies. Three discrete stable hybridoma clones secreting monoclonal antibodies (MAb) to pirenzepine were produced by fusing the myeloma line X63-Ag8.653 to spleen cells of BALB/c mice immunized with pirenzepine-5-N-propionate-protein conjugates. Of three carrier proteins investigated (HSA, BSA and edestin), optimal humoral immune responses and affinity of hybridoma antibody were attained using HSA. All three MAb displayed high affinity to pirenzepine (Ka = 0.6-1.2 X 10(9) l/mol) but showed differing cross-reactivities with its 4'-N-desmethyl metabolite (less than 1%, 6% and 40% respectively). The MAb with essentially zero metabolite cross-reactivity, 58-7/7, was selected for RIA development. In comparison, eight rabbit polyclonal antisera raised against pirenzepine-5-N-propionate-HSA or pirenzepine-5-N-butyrate-HSA possessed a similar range of affinities to the MAbs, but none approached MAb 58-7/7 in specificity. The bridge length had no significant effect on antisera characteristics. Competitive solid-phase RIAs for pirenzepine in human plasma and urine were established using MAb 58-7/7 and [3H]pirenzepine as tracer. All fluid transfers were automated using a programmable sample processing system (Microlab 2,000). Detection limits were 0.25 ng/ml (plasma) and 4 ng/ml (urine) in 0.1 ml sample. The coefficient of within-assay variation was 4% or better in the range 2-100 ng/ml (plasma) or 30-1,000 ng/ml (urine), the between-assay CV was 5.3% or better in the range 5-90 ng/ml (plasma) or 40-660 ng/ml (urine). Excellent correlation was observed between the plasma monoclonal RIA and the hitherto used polyclonal RIA (n = 106, r = 0.994), and between the urine monoclonal RIA and HPLC (n = 82, r = 0.998). We expect that these assays will prove valuable in pharmacokinetic and pharmacological investigations of pirenzepine.  相似文献   

12.
A high-performance liquid chromatographic method for automated analysis of both protein-bound and total S-2-(3-aminopropylamino)ethanethiol (WR-1065) in blood has been developed in our laboratory. WR-1065 is the active thiol metabolite of the radio- and chemo-protector drug amifostine (WR-2721). Using WR-1065 quality control levels over the experimental range: 7.0, 45.0 and 85.0 micromol/l spiked into plasma, method validation for total WR-1065 included between-run assessment of imprecision (SD/C.V.%: 1.11/16.7%, 6.58/15.5% and 9.24/11.3%, respectively) and % accuracy (94.7, 106.0 and 97.2%).  相似文献   

13.
Several methods for quantification of docetaxel have been described mainly using HPLC. We have developed a new isocratic HPLC method that is as sensitive and simpler than previous methods, and applicable to use in clinical pharmacokinetic analysis. Plasma samples are spiked with paclitaxel as internal standard and extracted manually on activated cyanopropyl end-capped solid-phase extraction columns followed by isocratic reversed-phase HPLC and UV detection at 227 nm. Using this system, the retention times for docetaxel and paclitaxel are 8.5 min and 10.5 min, respectively, with good resolution and without any interference from endogenous plasma constituents or docetaxel metabolites at these retention times. The total run time needed is only 13 min. The lower limit of quantification is 5 ng/ml using 1 ml of plasma. The validated quantitation range of the method is 5-1000 ng/ml with RSDs < or = 10%, but plasma concentrations up to 5000 ng/ml can be accurately measured using smaller aliquots. This method is also suitable for the determination of docetaxel in urine samples under the same conditions. The method has been used to assess the pharmacokinetics of docetaxel during a phase I/II study of docetaxel in combination with epirubicin and cyclophosphamide in patients with advanced cancer.  相似文献   

14.
15.
A HPLC assay with tandem mass spectrometric detection in the positive-ion atmospheric pressure chemical ionisation (APCI) mode for the sensitive determination of retigabine [(I), D-23129] and its acetyl metabolite [(II), ADW 21-360] in plasma was developed, utilising the structural analogue (D-10328), (III), as internal standard. Automated on-line solid-phase extraction of diluted plasma samples, based on 200-microl plasma aliquots, at pH 6.5, allowed a reliable quantification of retigabine and the acetyl metabolite down to 1 ng/ml. Injection of 500 microl of diluted plasma onto a C2 stationary phase-based column switching system in combination with a 75 mm x 4 mm reversed-phase analytical column at a flow-rate of 0.5 ml/min provided cycle times of 4 min per sample. The standard curves were linear from 1 to 1000 ng/ml using weighted linear regression analysis (1/x2). The method is accurate (mean accuracy < or = +/- 10%), precise (RSD < +/- 15%) and sensitive, providing lower limits of quantification in plasma of 1 ng/ml for retigabine (I), and 2.5 ng/ml for the metabolite (II) with limits of detection of 0.5 ng/ml for both analytes. Up to 200 unknowns may be analysed each 24 h per analyst.  相似文献   

16.
This study describes a chromatographic method for the determination of diazepam, an anxiolytic drug that is also used as an antidote against nerve agent seizures, its metabolites N-desmethyldiazepam, and temazepam, the anti-nerve agent drug pyridostigmine bromide (PB; 3-dimethylaminocarbonyloxy-N-methyl pyridinium bromide) and its metabolite N-methyl-3-hydroxypyridinium bromide in rat plasma and urine. The compounds were extracted using C18 Sep-Pak Vac 3cc (500 mg) cartridges and separated using isocratic mobile phase of methanol, acetonitrile and water (pH 3.2) (10:40:50) at a flow-rate of 0.5 ml/min in a period of 12 min, and UV detection ranging between 240 and 280 nm. The limits of detection for all analytes ranged between 20 and 50 ng/ml, while limits of quantitation were 100 ng/ml. Average percentage extraction recoveries of five spiked plasma samples were 79.1+/-7.7, 83.5+/-6.4, 83.9+/-5.9, 71.3+/-6.0 and 77.7+/-5.6, and from urine 79.4+/-7.9, 83.1+/-6.9, 73.6+/-7.7, 74.3+/-7.1 and 77.6+/-5.9 for diazepam, N-desmethyldiazepam, temazepam, pyridostigmine bromide, and N-methyl-3-hydroxypyridinium bromide, respectively. The relationship between peak areas and concentration was linear over the range between 100 and 1000 ng/ml. This method was applied to determine the above analytes following a single oral administration in rats as a tool to study the pharmacokinetic profile of each compound, alone and in combination.  相似文献   

17.
Sensitive high-performance liquid chromatographic (HPLC) methods have been developed and validated for the simultaneous determination of the antitumor drug topotecan and its metabolite N-desmethyltopotecan in human plasma, urine and faeces. Both compounds are reversibly hydrolysed to their hydroxycarboxylate forms at physiologic pH. Separate HPLC systems have been developed for the determination of lactone and total (lactone plus hydroxycarboxylate forms) concentrations in plasma. The instability of the analytes in plasma requires immediate protein precipitation with ice-cold methanol. The lactone forms of the analytes were stable in the methanol extracts for at least 15 months when stored at -70 degrees C. For the determination of the total levels, the plasma extracts were acidified with 25 mM phosphoric acid to convert the compounds into their lactone forms quantitatively. The sample pretreatment procedure for urine included dilution in methanol while the faecal samples were homogenized in distilled water and then extracted twice with an acetonitrile-ammonium acetate mixture. Separation was achieved on reversed-phase columns (Zorbax SB-C18) and detection was performed fluorimetrically at 380/527 nm. Within-run and between-run precisions were less than 10% and average accuracies were between 90 and 110%. The methods were used in a mass balance study in patients with malignant solid tumors to determine the disposition and routes of elimination of topotecan and N-desmethyltopotecan.  相似文献   

18.
Karenitecin is a novel, highly lipophilic camptothecin derivative with potent anticancer potential. We have developed a sensitive high-performance liquid chromatographic method for the determination of karenitecin concentration in human plasma and urine. Karenitecin was isolated from human plasma and urine using solid-phase extraction. Separation was achieved by gradient elution, using a water and acetonitrile mobile phase, on an ODS analytical column. Karenitecin was detected using fluorescence detection at excitation and emission wavelengths of 370 and 490 nm, respectively. Retention time for karenitecin was 16.2 +/- 0.5 min and 8.0 +/- 0.2 min for camptothecin, the internal standard. The karenitecin peak was baseline resolved, with the nearest peak at 3.1 min distance. Using normal volunteer plasma and urine from multiple individuals, as well as samples from the 50 patients analyzed to date, no interfering peaks were detected. Inter- and intra-day coefficients of variance were <4.4 and 7.1% for plasma and <4.9 and 11.6% for urine. Assay precision, based on an extracted karenitecin standard plasma sample of 2.5 ng/ml, was +4.46% with a mean accuracy of 92.4%. For extracted karenitecin standard urine samples of 2.5 ng/ml assay precision was +2.35% with a mean accuracy of 99.5%. The mean recovery of karenitecin, at plasma concentrations of 1.0 and 50 ng/ml, was 81.9 and 87.8% respectively. In urine, at concentrations of 1.5 and 50 ng/ml, the mean recoveries were 90.3 and 78.4% respectively. The lower limit of detection (LLD) for karenitecin was 0.5 ng/ml in plasma and 1.0 ng/ml in urine. The lower limit of quantification (LLQ) for karenitecin was 1 ng/ml and 1.5 ng/ml for plasma and urine, respectively. Stability studies indicate that when frozen at -70 degrees C, karenitecin is stable in human plasma for up to 3 months and in human urine for up to 1 month. This method is useful for the quantification of karenitecin in plasma and urine samples for clinical pharmacology studies in patients receiving this agent in clinical trials.  相似文献   

19.
An enantioselective high-performance liquid chromatography method was developed for the simultaneous determination of disopyramide (DP) and mono-N-dealkyldisopyramide (MND) enantiomers in plasma and urine. The drugs were extracted from plasma samples by liquid-liquid extraction with dichloromethane after protein precipitation with trichloroacetic acid; the urine samples were processed by liquid-liquid extraction with dichloromethane. The enantiomers were resolved on a Chiralpak AD column using hexane-ethanol (91:9, v/v) plus 0.1% diethylamine as the mobile phase and monitored at 270 nm. Under these conditions the enantiomeric fractions of the drug and of its metabolite were analyzed within 20 min. The extraction procedure was efficient in removing endogenous interferents and low values for the relative standard deviations were demonstrated for both within-day and between-day assays. The method described in this paper allows the determination of DP and MND enantiomers at plasma levels as low as 12.5 ng/ml and can be used in clinical pharmacokinetic studies.  相似文献   

20.
In order to discriminate selegiline (SG) use from methamphetamine (MA) use, the urinary metabolites of SG users have been investigated using high-performance liquid chromatography (HPLC)-electrospray ionization mass spectrometry (HPLC-ESI-MS). Selegiline-N-oxide (SGO), a specific metabolite of SG, was for the first time detected in the urine, in addition to other metabolites MA, amphetamine (AP) and desmethylselegiline (DM-SG). A combination of a Sep-pak C18 cartridge for the solid-phase extraction, a semi-micro SCX column (1.5 mm I.D.x 150 mm) for HPLC separation and ESI-MS for detection provided a simple and sensitive procedure for the simultaneous determination of these analytes. Acetonitrile-10 mM ammonium formate buffer adjusted to pH 3.0 (70:30, v/v) at a flow-rate of 0.1 ml/min was found to be the most effective mobile phase. Linear calibration curves were obtained over the concentration range from 0.5 to 100 ng/ml for all the analytes by monitoring each protonated molecular ion in the selected ion monitoring (SIM) mode. The detection limits ranged from 0.1 to 0.5 ng/ml. Upon applying the scan mode, 10-20 ng/ml were the detection limits. Quantitative investigation utilizing this revealed that SGO was about three times more abundant (47 ng/ml, 79 ng/ml) than DM-SG in two SG users' urine samples tested here. This newly-detected, specific metabolite SGO was found to be an effective indicator for SG administration.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号