共查询到20条相似文献,搜索用时 15 毫秒
1.
OBJECTIVES: To determine if there is added value to oncology studies performed with a dedicated in-line positron emission tomography (PET)/computed tomography (CT) scanner as compared with PET read side by side with diagnostic CT (DCT). METHODS: Forty-one consecutive oncology patients referred for PET/CT who had contemporary DCT scans for review were enrolled. Body regions assessed on a DCT scan were assessed on PET/CT and by side-by-side reading of PET and DCT (SBS PET/DCT). Lesions identified on DCT, the CT portion of PET/CT, SBS PET/DCT, and the reading of fused PET/CT images were scored as benign or malignant. The PET portion of the PET/CT study was read by 2 teams: the first read the SBS PET/DCT scan and the other read the complete fused PET/CT scan. For discordant lesions, the final diagnosis was determined by pathologic findings (n = 6) or imaging follow-up (n = 21). RESULTS: Twenty-seven (16.1%) of the 168 lesions were discordant when comparing analysis of fused PET/CT and SBS PET/DCT. Sixteen (9.5%) were fundamentally discordant, and 11(6.6%) were discordant in degree of confidence. For all discordant lesions only, the sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for PET/CT were 100%, 33%, 100%, 94%, and 78%, respectively, and for SBS PET/DCT, they were 38%, 50%, 19%, 73%, and 30%, respectively (P < 0.001 for sensitivity, P = not specific for specificity). The 2 main causes for misclassification on SBS PET/DCT were incorrect localization (n = 12) and changes occurring in the time gap between DCT and PET/CT (n = 4). CONCLUSIONS: In-line PET/CT offers better lesion localization in comparison to the visual fusion of PET and CT, especially for small lymph nodes, lesions adjacent to mobile organs, or lesions adjacent to the chest or abdominal wall. 相似文献
2.
Kjell Någren Christer Halldin Juha O. Rinne 《European journal of nuclear medicine and molecular imaging》2010,37(8):1575-1593
Alzheimer’s disease (AD) is a common degenerative neurological disease that is an increasing medical, economical, and social
problem. There is evidence that a long “asymptomatic” phase of the disease exists where functional changes in the brain are
present, but structural imaging for instance with magnetic resonance imaging remains normal. Positron emission tomography
(PET) is one of the tools by which it is possible to explore changes in cerebral blood flow and metabolism and the functioning
of different neurotransmitter systems. More recently, investigation of protein aggregations such as amyloid deposits or neurofibrillary
tangles containing tau-protein has become possible. The purpose of this paper is to review the current knowledge on various
18F- and 11C-labelled PET tracers that could be used to study the pathophysiology of AD, to be used in the early or differential diagnosis
or to be used in development of treatment and in monitoring of treatment effects. 相似文献
3.
Kimiteru Ito Ryogo Minamimoto Hiroyuki Yamashita Setsuko Yoshida Miyako Morooka Momoko Okasaki Akio Mimori Kazuo Kubota 《Annals of nuclear medicine》2013,27(3):209-216
Objective
Wegener’s granulomatosis (WG) is a relatively rare disease characterized by granulomatous necrotizing vasculitis that primarily involves small- and medium-sized vessels. Systemic findings observed on 18F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) have not been well reported. The purpose of this study was to evaluate the FDG PET/CT imaging in the diagnosis and follow-up of patients with WG.Materials and methods
Thirteen FDG PET/CT images obtained for 8 patients (2 men and 6 women) with WG were retrospectively analyzed. Of these, 6 were performed for diagnosis, 2 for restaging and follow-up, and 5 for assessment of treatment efficacy. Maximum standardized uptake values (max SUVs) and visual analyses were used to interpret the FDG PET/CT images. In addition, nonenhanced CT findings obtained during FDG PET/CT were described.Results
WG lesions of the upper respiratory tract and lung were more clearly detected by FDG PET/CT fusion imaging than by nonenhanced CT alone, and all of the active lesions showed decreased FDG uptake after treatment. In addition, FDG PET/CT can provide complementary information to indicate biopsy site based on FDG uptakes.Conclusions
FDG PET/CT is a feasible modality for evaluating lesion activities, therapeutic monitoring, and follow-up of WG. Furthermore, biopsy sites of WG lesions may be determined by FDG PET/CT. 相似文献4.
Keiko Aoyagi Tomio Inoue Yasuhiko Yamauchi Tsutomu Iwasaki Keigo Endo 《Annals of nuclear medicine》1998,12(4):197-204
Objective
The aim of this study is to evaluate the diagnostic accuracy of myocardial201T1 SPECT combined with EBT for detecting CAD.Methods
The study was based on 34 patients with suspected CAD, who had EBT and myocardial201Tl SPECT. The CAD was diagnosed by the findings of coronary arteriography. Sensitivity, specificity and accuracy of EBT, myocardial201Tl SPECT and the combined diagnosis on a per vessel basis and a per-patient basis were studied.Results
The sensitivity for detecting CAD of myocardial201Tl SPECT, EBT and the combined diagnosis was 85%, 77%, and 62%, respectively. No significant difference in the accuracy of myocardial201T1 SPECT, EBT and the combined diagnosis was observed on a patient basis and per vessel basis. In the over 70 yr age subgroup, the sensitivity and accuracy of EBT for detecting LAD lesion were significantly superior to those of myocardial201Tl SPECT. Regardless of age-based subgroups and gender, the combined diagnosis did not contribute to an improvement in diagnostic accuracy.Conclusion
Although the sensitivity of EBT for detecting LAD lesion in patients over 70 yr of age was significantly higher than that of myocardial201Tl SPECT, in the detectability of CAD, combined use of myocardial201Tl SPECT and EBT offers no improvement. 相似文献5.
Fricke E Fricke H Eckert S Zijlstra S Weise R Lindner O Horstkotte D Burchert W 《European journal of nuclear medicine and molecular imaging》2007,34(2):206-211
Purpose Higher sensitivity of sympathetic nerves to ischaemia in comparison with myocytes has been observed and has been claimed to
contribute to poor prognosis in patients with coronary artery disease (CAD). The aim of this study was to evaluate the dependency
of myocardial sympathetic innervation on restrictions in coronary flow reserve (CFR).
Methods We analysed 27 non-diabetic patients with advanced CAD. We determined quantitative myocardial blood flow using 13N-ammonia PET, myocardial viability with 18F-FDG PET and cardiac innervation with 11C-HED PET. Scarred segments were excluded from analysis. We investigated the relationship between regional HED retention,
blood flow and CFR.
Results There was no correlation between rest perfusion and HED retention within a flow range from approximately 30 to 120 ml/(100 ml·min).
A slight correlation was observed between stress perfusion values and HED retention (p<0.001), and between CFR and HED retention (p<0.001).
Conclusion In non-diabetic CAD patients, HED retention in vital myocardium does not correlate with myocardial rest perfusion over a large
flow range. The observed relation between HED retention and CFR indicates that sympathetic innervation can be preserved even
when there is major impairment of myocardial blood supply. Most probably the occurrence of denervation depends not only on
reductions in CFR, but also on the duration and severity of resulting ischaemic episodes. 相似文献
6.
Jens Toft Dan Lindahl Matthias Ohlsson John Palmer Anders Lundin Lars Edenbrandt Birger Hesse 《European journal of nuclear medicine and molecular imaging》2001,28(7):831-835
Both subjects with a low likelihood for coronary artery disease (CAD) and patients with normal findings on coronary angiography have been used as reference populations in non-invasive stress testing, including myocardial perfusion scintigraphy. Both of these criteria of normality - low likelihood of CAD and normal coronary angiography - have been criticised, and consensus on this issue is lacking. The aim of this study was to compare two different reference populations by testing the performance of artificial neural networks designed to interpret myocardial scintigrams. The networks were trained on myocardial perfusion scintigrams from 87 patients with angiographically documented CAD and on studies from one of two different reference groups: 48 patients with no signs of CAD based on angiography or 128 healthy volunteers with a likelihood for CAD <5%. The performance of the two different networks was then tested using scintigrams from a separate test group of 68 patients. Coronary angiography was used as the gold standard in this group. The network trained on patients with no signs of CAD based on angiography showed an area under the receiver operating characteristic (ROC) curve of 93%. The ROC area for the network trained on healthy volunteers was 72%, and this difference was statistically significant (P=0.03). The results of this study using artificial neural networks suggest that normal angiography should be preferred as the reference standard in myocardial scintigraphy when a patient is examined for CAD prior to possible angiography. Whether the same is true for other indications, e.g. in prognostic evaluation, is unknown. 相似文献
7.
Svante Nyberg Maria Eriksdotter Jönhagen Zsolt Cselényi Christer Halldin Per Julin Hans Olsson Yvonne Freund-Levi Jan Andersson Katarina Varnäs Samuel Svensson Lars Farde 《European journal of nuclear medicine and molecular imaging》2009,36(11):1859-1863
Purpose
Current positron emission tomography (PET) radioligands for detection of Aβ amyloid in Alzheimer’s disease (AD) are not ideal for quantification. To improve the signal to noise ratio we have developed the radioligand [11C]AZD2184 and report here the first clinical evaluation.Methods
Eight AD patients and four younger control subjects underwent 93-min PET measurements with [11C]AZD2184. A ratio approach using the cerebellum as reference region was applied to determine binding parameters.Results
Brain uptake of [11C]AZD2184 peaked within 1 min at 3–4% of injected radioactivity. AD patients had high radioactivity in cortical regions while controls had uniformly low radioactivity uptake. Specific binding peaked within 30 min at which time standardized uptake value ratios (SUVR) ranged between 1.19 and 2.57.Conclusion
[11C]AZD2184 is a promising radioligand for detailed mapping of Aβ amyloid depositions in Alzheimer’s disease, due to low non-specific binding, high signal to background ratio and reversible binding as evident from early peak equilibrium. 相似文献8.
Toft J Lindahl D Ohlsson M Palmer J Lundin A Edenbrandt L Hesse B 《European journal of nuclear medicine》2001,28(7):831-835
Both subjects with a low likelihood for coronary artery disease (CAD) and patients with normal findings on coronary angiography have been used as reference populations in non-invasive stress testing, including myocardial perfusion scintigraphy. Both of these criteria of normality--low likelihood of CAD and normal coronary angiography--have been criticised, and consensus on this issue is lacking. The aim of this study was to compare two different reference populations by testing the performance of artificial neural networks designed to interpret myocardial scintigrams. The networks were trained on myocardial perfusion scintigrams from 87 patients with angiographically documented CAD and on studies from one of two different reference groups: 48 patients with no signs of CAD based on angiography or 128 healthy volunteers with a likelihood for CAD <5%. The performance of the two different networks was then tested using scintigrams from a separate test group of 68 patients. Coronary angiography was used as the gold standard in this group. The network trained on patients with no signs of CAD based on angiography showed an area under the receiver operating characteristic (ROC) curve of 93%. The ROC area for the network trained on healthy volunteers was 72%, and this difference was statistically significant (P=0.03). The results of this study using artificial neural networks suggest that normal angiography should be preferred as the reference standard in myocardial scintigraphy when a patient is examined for CAD prior to possible angiography. Whether the same is true for other indications, e.g. in prognostic evaluation, is unknown. 相似文献
9.
Toyama T Hoshizaki H Seki R Isobe N Oshima S Taniguchi K Higuchi K Seki H Hatori T Kurabayashi M Endo K 《Annals of nuclear medicine》2004,18(6):463-468
OBJECTIVE AND METHODS: The aim of this study was to evaluate myocardial viability in patients after acute myocardial infarction (AMI). We compared 201Tl SPECT after 201Tl with GIK (10% glucose 250 ml, insulin 5 U and KCl 10 mEq) infusion (GIK-201Tl) with resting 201Tl and 99mTc-pyrophosphate (PYP) dual SPECT, positron emission computed tomography (PET) using 18F-fluorodeoxyglucose (18F-FDG) in 21 patients with their first AMI, who all underwent successful reperfusion. GIK-201Tl SPECT, 201Tl and 99mTc-PYP dual SPECT were done within 10 days after admission and 18F-FDG-PET was performed at 3 weeks. GIK-201Tl SPECT was obtained after 30 min of GIK-201Tl infusion. 18F-FDG (370 MBq) was injected intravenously after oral glucose (1 g/ kg) loading, and then PET was obtained. PET and SPECT images were divided into 20 segments. Regional tracer uptake was scored using a 4-point scoring system (3 = normal to 0 = defect), and summed to a regional uptake score (RUS). Regional area means the infarcted area in which 99mTc-PYP accumulated. The number of decreased uptake segments (ES) was then determined. The infarcted area was defined as the area of 99mTc-PYP uptake. RESULTS: The ESs for the GIK-201Tl and 18F-FDG-PET images were significantly lower than the number of 99mTc-PYP uptake segments. The RUS for GIK-201Tl was higher than that for resting-201Tl imaging and similar to those for 18F-FDG-PET. CONCLUSIONS: In the detection of myocardial viability following AMI, GIK-201Tl imaging is useful with findings similar to those of 18F-FDG-PET. 相似文献
10.
11.
12.
Background
The location of a myocardial perfusion abnormality frequently affects clinical decision making, especially if the left anterior descending artery (LAD) territory is involved. The purpose of this study was to determine whether the location of abnormalities on single-photon emission computed tomography (SPECT) imaging affects outcomes.Methods
We retrospectively analyzed 21,294 consecutive patients with known or suspected coronary artery disease who underwent exercise or pharmacological stress SPECT over a 10-year period. Using the ASNC 17-segment model, 2 observers interpreted images with regards to defect severity, size, and reversibility. The summed stress score (SSS) was used in relation to vascular territories [LAD, right coronary artery (RCA), and left circumflex artery (LCx)]. All patients were followed over a mean period of 2.5?±?2?years for cardiac events (cardiac death or non-fatal myocardial infarction).Results
Of the enrolled patients, 5,676 had single-vessel territory defects with a mean SSS of 4.3?±?2.8. Cardiac event-free survival curves revealed no significant difference between the 3 locations (LAD, RCA, and LCx) (P?=?.235). When compared by mild (2-3), moderate (4-8), or severe (>8) SSS, outcomes between the 3 groups were again similar. There were 2,907 patients with two-vessel territory defects with a mean SSS of 10.8. Outcomes were similar between the following 2 groups: two-vessel with LAD involvement and two-vessel without LAD involvement (P?=?.558).Conclusion
In patients with single- or two-vessel territory perfusion abnormalities with similar size and severity of perfusion defects, the location of defect did not impact future cardiac events. Location of myocardial perfusion defect on SPECT imaging may not be helpful in clinical decision making. 相似文献13.
14.
Frank M. Bengel Bernhard Permanetter Martin Ungerer Stephan Nekolla Markus Schwaiger 《European journal of nuclear medicine and molecular imaging》2000,27(3):319-326
The clearance kinetics of carbon-11 acetate, assessed by positron emission tomography (PET),can be combined with measurements
of ventricular function for non-invasive estimation of myocardial oxygen consumption and efficiency. In the present study,
this approach was applied to gain further insights into alterations in the failing heart by comparison with results obtained
in normals. We studied ten patients with idiopathic dilated cardiomyopathy (DCM) and 11 healthy normals by dynamic PET with
11C-acetate and either tomographic radionuclide ventriculography or cine magnetic resonance imaging. A ”stroke work index” (SWI)
was calculated by: SWI = systolic blood pressure × stroke volume/body surface area. To estimate myocardial efficiency, a ”work-metabolic
index” (WMI) was then obtained as follows: WMI = SWI × heart rate/k(mono), where k(mono) is the washout constant for 11C-acetate derived from mono-exponential fitting. In DCM patients, left ventricular ejection fraction was 19%±10% and end-diastolic
volume was 92±28 ml/m2 (vs 64%±7% and 55±8 ml/m2 in normals, P<0.001). Myocardial oxidative metabolism, reflected by k(mono), was significantly lower compared with that in normals (0.040±0.011/min vs 0.060± 0.015/min; P<0.003). The SWI (1674±761 vs 4736± 895 mmHg × ml/m2; P<0.001) and the WMI as an estimate of efficiency (2.98±1.30 vs 6.20±2.25×106 mmHg × ml/m2; P<0.001) were lower in DCM patients, too. Overall, the WMI correlated positively with ejection parameters (r=0.73, P<0.001 for ejection fraction; r=0.93, P<0.001 for stroke volume), and inversely with systemic vascular resistance (r=–0.77; P<0.001). There was a weak positive correlation between WMI and end-diastolic volume in normals (r=0.45; P=0.17), while in DCM patients, a non-significant negative correlation coefficient (r=–0.21; P=0.57) was obtained. In conclusion non-invasive estimates of oxygen consumption and efficiency in the failing heart were reduced
compared with those in normals. Estimates of efficiency increased with increasing contractile performance, and decreased with
increasing ventricular afterload. In contrast to normals, the failing heart was not able to respond with an increase in efficiency
to increasing ventricular volume. The present data support the usefulness of the WMI for non-invasive characterization of
cardiac efficiency and may serve as a background for improved evaluation of medical therapy for heart failure.
Received 10 August and in revised form 3 November 1999 相似文献
15.
Nakamoto Y Nogami M Sugihara R Sugimura K Senda M Togashi K 《Annals of nuclear medicine》2011,25(2):93-99
Purpose
Positron emission tomography (PET)/computed tomography (CT) with 18F-fluorodeoxyglucose is widely used for post-therapeutic surveillance of malignant lymphoma. Debate still exists as to whether intravenous contrast media during the CT stage of a PET/CT scan should be used. The purpose of this study was to investigate the clinical value of contrast agent in PET/CT in patients with lymphoma following treatment. 相似文献16.
Grant T. Gullberg Edward V. R. Di Bella Albert J. Sinusas 《Journal of nuclear cardiology》2001,8(5):620-625
Conclusion SPECT can obtain CFR measurements, both globally and regionally. Positive SPECT results, as well as positive PET results,
depend upon the tracer having a constant extraction fraction over the flow range being studied. SPECT approaches will probably
not be as accurate as dynamic PET for estimation of CFR because spatial and timing resolution is poorer. Also, the radiopharmaceuticals
may not track flow as effectively as O-15 water. The method presented by Sugihara et al is simpler than dynamic cardiac SPECT
with compartment modeling; however, the technique works only for radiopharmaceuticals that act like microspheres. It is important
that the extraction remain constant over a large flow range. The microsphere method also relies on not having any wash-out
from the tissue from the time of injection to the time of measurement. Dynamic cardiac SPECT works best with radiopharmaceuticals
that have high extraction. These radiopharmaceuticals are not as fast as the ideal flow tracer O-15 water. However, because
of the inadequate timing resolutions of commercial SPECT systems, it would be virtually impossible to image such flow tracers.
Research is still needed in the following areas. (1) Further studies should be done to determine what mechanisms govern maximal
coronary vasodilation. (2) There should be a determination of how these new SPECT approaches can be evaluated and tested in
human beings. It has yet to be determined whether use of the coronary flow or pressure wire would be better. Perhaps comparison
to dynamic PET imaging alone would be sufficient. (3) Systematic studies should be done to define the distribution of absolute
CFR in both normal and abnormal hearts and to determine how the common factors that can diminish CFR affect regional reserve,
especially in small subendocardial regions. To truly define coronary vascular reserve, it is essential that subendocardial
measurements of CFR be obtainable. (4) Technological advances must be made in order to improve SPECT imaging systems so that
they better facilitate dynamic imaging. Current SPECT systems have been limited by low sensitivity, poor resolution, and poor
temporal resolution as a result of the necessary mechanical rotation of the detector. However, recent advancements in dynamic
cardiac SPECT, drawn from developments in PET, demonstrate that dynamic cardiac SPECT is useful for the extraction of physiologic
values of perfusion38 in a manner similar to that of dynamic PET. These systems allow volumetric imaging but do not require
sampling at rates of less than 5 seconds because of the lack of sufficient statistical data. 相似文献
17.
《Gait & posture》2020
BackgroundGait disturbance is one of the most common symptoms among patients with idiopathic Parkinson’s disease (IPD). Nevertheless, Parkinson’s disease subtype clustering according to gait characteristics has not been thoroughly investigated.Research questionThe aim of this study was to identify subgroups according to gait pattern among patients with IPD.MethodsThis study included 88 patients with IPD who underwent 18F-fluorinated-N-3-fluoropropyl-2-β-carboxymethoxy-3-β-4-iodophenyl-nortropane positron emission tomography (18F-FP-CIT PET) and three-dimensional gait analysis (3DGA) between January 1, 2014 and December 31, 2016. We performed cluster analysis using temporal-spatial gait variables (gait speed, stride length, cadence, and step width) and divided patients into four subgroups. The kinematic and kinetic gait variables in 3DGA were compared among the four subgroups. Furthermore, we compared the uptake patterns of striatum among the four subgroups using 18F-FP-CIT PET.ResultsThe patients were clustered into subgroups based on gait hypokinesia and cadence compensation. Group 1 had decreased stride length compensating with increased cadence. Group 2 had decreased stride length without cadence compensation and wider step width. Group 3 had relatively spared stride length with decreased cadence. Group 4 had spared stride length and cadence. The uptake of posterior putamen was significantly decreased in Group 3 compared with Group 4.SignificanceGait hypokinesia and cadence can help to classify gait patterns in IPD patients. Our subgroups may reflect the different gait patterns in IPD patients. 相似文献
18.
Olivio F. Donati Paul Stolzmann Lotus Desbiolles Sebastian Leschka Sebastian Kozerke André Plass Christophe Wyss Volkmar Falk Borut Marincek Hatem Alkadhi Hans Scheffel 《European journal of radiology》2011,80(1):120-126
Purpose
To prospectively determine the best cut-off value of stenosis degree for low-dose computed tomography coronary angiography (CTCA) to predict the hemodynamic significance of coronary artery stenoses compared to catheter angiography (CA) using a cardiac magnetic resonance based approach as standard of reference.Materials and methods
Fifty-two patients (mean age, 64 ± 10 years) scheduled for CA underwent cardiac magnetic resonance (CMR) at 1.5-T and dual-source CTCA using prospective ECG-triggering the same day. Diagnostic performance of CTCA and CA to detect myocardial ischemia was evaluated with CMR as the standard of reference. The diagnostic performance and best cut-off values to predict the hemodynamic significance of coronary were determined from receiver operating characteristics analysis (ROC).Results
CA revealed >50% stenoses in 131/832 segments (15.7%) in 78/156 (50.0%) coronary arteries in 32/52 (62%) patients. CTCA revealed >50% stenoses in 148/807 (18.3%) segments, corresponding to 83/156 (53.2%) coronary arteries in 34/52 (65.4%) patients. CMR revealed ischemia in 118/832 (14.2%) myocardial segments corresponding to the territories of 60/156 (38.5%) coronary arteries in 29/52 (56%) patients. ROC analysis showed equal diagnostic performance for low-dose CTCA and CA with areas under the curve (AUC) of 0.82 and 0.83 (P = 0.64). The optimal cut-off value was determined at stenosis of >60% for the prediction of hemodynamically significant coronary stenosis by CTCA. Using this cut-off value, sensitivity, specificity, NPV and PPV to predict hemodynamic significance by CTCA were 100%, 83%, 100%, and 88% on a per-patient basis and 88%, 73%, 83% and 81% on a per-artery analysis, respectively.Conclusion
By considering coronary stenosis >60%, diagnostic performance for predicting the hemodynamic significance of coronary stenosis by CTCA is optimal and equals that of CA. 相似文献19.
Tatsuhiro Terada Masamichi Yokokura Etsuji Yoshikawa Masami Futatsubashi Satoshi Kono Takashi Konishi Hiroaki Miyajima Takanori Hashizume Yasuomi Ouchi 《Annals of nuclear medicine》2016,30(8):579-587
Background
The neuroinflammatory glial response contributes to the degenerative process in Parkinson’s disease (PD). However, the pattern of microglial progression remains unclear.Methods
We evaluated microglial activation in early stage PD patients by quantifying changes in neuroinflammation using PET with [11C]DPA713, a selective PET tracer for microglial activation. Eleven PD patients (Hoehn and Yahr stages 1–2) without dementia underwent the [11C]DPA713 PET scan two times with 1 year apart. The binding potential (BPND) was estimated with the simplified reference tissue model. Voxelwise and regions of interest analyses were used to compare the regional BPND among groups.Results
Significant increase in [11C]DPA713 BPND was found extrastriatally in the occipital, temporal and parietal cortex in PD patients, and the degree of BPND became much higher over the brain regions predominantly in the temporal and occipital cortex 1 year later.Conclusion
The current results indicated that an extrastriatal spreading of microglial activation reflects one of PD pathophysiology occurring at an early stage.20.
Nair SU Ahlberg AW Mathur S Katten DM Polk DM Heller GV 《Journal of nuclear cardiology》2012,19(2):244-255