首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 515 毫秒
1.
2.
3.
《Seminars in Arthroplasty》2014,25(4):246-249
With variation in glenoid design focused mainly on the backside interface of the component with the glenoid bone, keeled and pegged glenoid components have become the basis for most implants. Keeled implants offer a single, deep anchor for the component, while pegged implants offer stability with less bone removal. There is a trend in multiple studies for decreased radiolucent lines, decreased loosening, and decreased revision rates with pegged components. In-line pegs confer several advantages over out-of-line pegs. Advancements in cementing techniques and glenoid preparation have improved longevity for all types of glenoid implants.  相似文献   

4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
14.
15.
16.
17.
18.
19.
20.
The purpose of this study was to evaluate glenoid‐sided lateralization in reverse shoulder arthroplasty (RSA), and compare bony and prosthetic lateralization. The hypothesis was that stress and displacement would increase with progressive bony lateralization, and be lower with prosthetic lateralization. A 3D finite element analysis (FEA) was performed on a commercially available RSA prosthesis. Stress and displacement were evaluated at baseline and following 5, 10, and 15 mm of bony or prosthetic lateralization. Additional variables included glenosphere size, baseplate orientation, and peripheral screw orientation. Maximum stress for a 36 mm glenosphere without bone graft increased by 137% for the 5 mm graft, 187% for the 10 mm graft, and 196% for the 15 mm graft. Likewise, displacement progressively increased with increasing graft thickness. Stress and displacement were reduced with a smaller glenosphere, inferior tilt of the baseplate, and divergent peripheral screws. Compared to bony lateralization, stress was lower with prosthetic lateralization through the glenosphere or baseplate. Displacement with 5 mm of bony lateralization reached recommended maximal amounts for osseous integration, whereas, this level was not reached until 10–15 mm of prosthetic lateralization. Baseplate stress and displacement in an FEA model is lower with a smaller glenosphere, inferior tilt, and divergent screws. Bony lateralization increases stress and displacement to a greater degree than prosthetic lateralization. It appears that at least 10 mm of prosthetic lateralization is mechanically acceptable during RSA, but only 5 mm of bony lateralization is advised. © 2016 Orthopaedic Research Society. Published by Wiley Periodicals, Inc. J Orthop Res 35:1548–1555, 2017.
  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号