首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 609 毫秒
1.
《Radiography》2020,26(4):e277-e283
IntroductionThere is limited research related to the radiographers' role in assessing of radiology referrals to justify imaging. This study investigated radiographers' compliance with guidelines in the assessment of CT and MRI referrals and factors that influenced their performance.MethodsThis research was facilitated by the EFRS Research Hub at ECR 2019. Five radiology referral scenarios for CT and/or MRI were distributed to radiographers, as determined by their scope of practice, who volunteered at the Research Hub. A web-based data collection tool was used. The radiographers were required to determine the appropriateness of each referral, highlight any concerns and recommend suitable investigations if applicable. Linear regression analysis was used to determine whether postgraduate qualification, grade/role of the radiographer and use of guidelines influenced the radiographers' performance in assessing the referrals.ResultsParticipants originated from 24 countries (n = 51 CT, n = 40 MRI), the majority originating from the UK, Ireland, Italy, Spain, Norway and Austria. Responses consistent with guidelines were 58% and 57% for CT and MRI, respectively. Possession of an MSc qualification in CT was a significant factor of influence for a higher consistency with guidelines (p = 0.02) in CT. Employment as a radiographer in a lead professional role and/or educator was a significant factor of influence for a higher consistency with guidelines in MRI (p = 0.01).ConclusionA total of 58% for CT and 57% for MRI of the radiographers' responses complied with guidelines. Factors such as postgraduate education and leading professional roles are associated with better performance.Implications for practiceConsidering qualifications, experience and managerial role is vital before radiographers are delegated task of justifying CT and MR Imaging.  相似文献   

2.
《Radiography》2022,28(2):460-465
IntroductionWith the annual increase in medical imaging demand, the appropriateness of the lumbar spine magnetic resonance imaging LSMRI referrals is worldwide gaining attention. This study aims to determine the appropriateness of LSMRI referrals and compare radiology clinical decisions to iRefer compliance based solely on referral text content.MethodsReferral text was extracted from 1021 LSMRI referrals. Two review panels were recruited: three expert radiologists and three MRI radiographers. Radiologists classified cases as indicated or not indicated for scanning based on their clinical judgement. The radiographers classified based solely on iRefer guidelines. Majority voting for each case was applied to both review panels and reviewer agreement was tested using Kappa analysis. Logistic regression models were developed to identify medical disciplines associated with high rates of indicated referrals.Results21.7% and 11.9% of the cases were found not indicated for MRI for radiologists and radiographers, respectively. Radiology review identified 18% of the GPs referrals as not indicated and 17% in the radiographers’ review. Panel agreement was fair: Kappa values of 0.23 and0.26 for the radiologists and radiographers respectively. Neurosurgery was associated with the highest rate of indicated referrals across both review panels: oncology referrals raised the highest number of open comments.ConclusionThe study identified a lower number of not indicated referrals compared to previous research. Findings indicate the importance of both guidelines compliance and clinical judgement to optimise practice.Implications for practiceFindings in this study found that even when strict instructions were given to the MR radiographers to vet referrals using the iRefer guidelines, ambiguity within the guidelines resulted in variations in decision-making. This suggests that detailed protocols are required to support radiographers in the vetting process to ensure a standardised approach.  相似文献   

3.
IntroductionThis study investigates instances of elevated radiation dose on a radiation tracking system to determine their aetiologies. It aimed to investigate the impact of radiographer feedback on these alerts.MethodsOver two six-month periods 11,298 CT examinations were assessed using DoseWatch. Red alerts (dose length products twice the median) were identified and two independent reviewers established whether alerts were true (unjustifiable) or false (justifiable). During the second time period radiographers used a feedback tool to state the cause of the alert. A Chi–Square test was used to assess whether red alert incidence decreased following the implementation of radiographer feedback.ResultsThere were 206 and 357 alerts during the first and second time periods, respectively. These occurred commonly with CT pulmonary angiography, brain, and body examinations. Procedural documentation errors and patient size accounted for 57% and 43% of false alerts, respectively. Radiographer feedback was provided for 17% of studies; this was not associated with a significant change in the number of alerts, but the number of true alerts declined (from 7 to 3) (χ2 = 4.14; p = 0.04).ConclusionProcedural documentation errors as well as patient-related factors are associated with false alerts in DoseWatch. Implementation of a radiographer feedback tool reduced true alerts.Implications for practiceThe implementation of a radiographer feedback tool reduced the rate of true dose alerts. Low uptake with dose alert systems is an issue; the workflow needs to be considered to address this.  相似文献   

4.
《Radiography》2022,28(2):276-282
IntroductionThe topic of healthcare human resource planning for diagnostic radiographers has received limited research attention to date. This research is concerned with developing a framework that can be used to determine diagnostic radiographer staffing requirements at a unit- or department level (i.e. at the micro-level).MethodsAn inductive approach is applied to formulate requirement specifications that inform the development of the framework. A number of verification and validation activities are performed, including theoretical verification and a case study application.ResultsThe diagnostic radiographer staffing framework consists of seven steps that comprise a workload-based approach to determining the number of full time equivalent diagnostic radiographers that are required for each modality, or group of modalities. Both clinical and non-clinical activities are considered, and guidance is provided on calculating staffing requirements to cover leave allowances. A number of potential approaches to determining activity times are also discussed.ConclusionThe framework represents a holistic approach to determining the required number of diagnostic radiographers at a practice-level, that is designed to remain relevant as technological advances are made in the field of diagnostic radiography.Implications for practiceBy providing a practical guideline, with accompanying examples, the framework is expected to hold value for individuals involved in the management of diagnostic radiography practices. The framework proposes an approach to a topic that affects every radiography practice in operation yet has received limited attention in literature to date.  相似文献   

5.
6.
7.
《Radiography》2020,26(3):198-204
IntroductionDiagnostic student radiographer attrition is reported at 14%, 6% higher than the average for higher education, however, little research has been undertaken on this subject. This study explored risk factors for attrition and strategies that enabled these to be overcome.MethodsA two-phase study was undertaken. Phase one: data for 579 former student diagnostic radiographers (468 completers and 111 non-completers) from 3 English universities were analysed. Logistic regression was used to estimate odds ratios and 95% confidence intervals for completion based on individual characteristics. Phase two: content analysis of data from an online survey of 186 current UK student diagnostic radiographers exploring their experiences was undertaken.ResultsPhase one: Attrition was 19%. Increased age, non A-level entry qualifications and poor academic performance were predictors of attrition (p < 0.005). Phase two: Challenges reported by groups identified as ‘at risk’ showed that for mature students and those with non-traditional entry qualifications, external responsibilities/pressures and financial pressures were likely to be the greatest cause of attrition and for younger students with traditional qualifications, academic difficulty and excessive workload were most significant. Scientific learning and academic writing were identified as the most common academic difficulties by all groups. Poor mental health may also be a risk factor.ConclusionAlthough characteristics were identified that increased the chance of attrition, the study concluded that attrition is most likely to be multi-factorial. Academic and personal support were identified as key in students continuing their studies when they considered leaving. Clinical placement experience is likely to influence continuation decisions.Implications for practiceTransparency around course expectations and academic requirements together with ensuring high quality clinical placements may assist in reducing attrition.  相似文献   

8.
PurposeTo compare the mechanical properties of aneurysm content after endoleak embolization with a chitosan hydrogel (CH) with that with a chitosan hydrogel with sodium tetradecyl sulfate (CH-STS) using strain ultrasound elastography (SUE).Materials and MethodsBilateral common iliac artery type Ia endoleaks were created in 9 dogs. Per animal, 1 endoleak was randomized to blinded embolization with CH, and the other, with CH-STS. Brightness-mode ultrasound, Doppler ultrasound, SUE radiofrequency ultrasound, and computed tomography were performed for up to 6 months until sacrifice. Radiologic and histopathologic studies were coregistered to identify 3 regions of interest: the embolic agent, intraluminal thrombus (ILT), and aneurysm sac. SUE segmentations were performed by 2 blinded independent observers. The maximum axial strain (MAS) was the primary outcome. Statistical analysis was performed using the Fisher exact test, multivariable linear mixed-effects models, and intraclass correlation coefficients (ICCs).ResultsResidual endoleaks were identified in 7 of 9 (78%) and 4 of 9 (44%) aneurysms embolized with CH and CH-STS, respectively (P = .3348). CH-STS had a 66% lower MAS (P < .001) than CH. The ILT had a 37% lower MAS (P = .01) than CH and a 77% greater MAS (P = .079) than CH-STS. There was no significant difference in ILT between treatments. The aneurysm sacs embolized with CH-STS had a 29% lower MAS (P < .001) than those embolized with CH. Residual endoleak was associated with a 53% greater MAS (P < .001). The ICC for MAS was 0.807 (95% confidence interval: 0.754–0.849) between segmentations.ConclusionsCH-STS confers stiffer intraluminal properties to embolized aneurysms. Persistent endoleaks are associated with increased sac strain, an observation that may help guide management.  相似文献   

9.
BackgroundOnsite workstation-based CT-derived Fractional-Flow-Reserve (CT-FFR) is accurate in assessing hemodynamic-significance of coronary stenoses. We aim to describe the influence of operator expertise and luminal-segmentation technique on the diagnostic performance, precision and reproducibility of CT-FFR in identifying hemodynamically-significant stenosis (FFR≤0.8).MethodsForty-eight consecutive stable-patients (86 vessels) with suspected CAD underwent research indicated invasive-FFR and 320-detector CT-coronary-angiography (CTA). CT-FFR was derived using reduced-order model on standard desktop-computer. Semi-automated coronary luminal segmentation was performed using focused-technique with manual adjustments at regions of stenosis and calcification or comprehensive-technique with manual adjustments along the entire course of the vessel. CT-FFR analysis was performed using 3 blinded operators; core-laboratory engineer using focused-technique and radiographer and cardiologist using the comprehensive-technique. Diagnostic performance was assessed by area under receiver-operating-curve (AUC). Precision with invasive FFR was determined by Bland-Altman analysis, and reproducibility by intraclass-correlation-coefficient (ICC).ResultsDiagnostic performance was comparable among operators (Engineer: AUC = 0.88, Radiographer 0.84; Cardiologist 0.87; P = 0.59). Coronary luminal-segmentation time was shortest using focused technique (engineer 6:17 ± 2.43 min), compared with comprehensive technique (cardiologist 14.83 ± 7.09, radiographer 24.74 ± 12.65; P < 0.001). Use of focused technique was associated with widest limits of agreement (LOA) with FFR and moderate intra-operator reproducibility (engineer LOA -0.20-0.33; ICC 0.66), when compared with the comprehensive technique which demonstrated narrower LOA and excellent reproducibility [radiographer (LOA -0.17-0.20, ICC = 0.91) and cardiologist (LOA-0.15-0.23, ICC = −0.93)]ConclusionA workstation-based CT-FFR technique was reproducible with high and comparable diagnostic performance among operators with different expertise. A comprehensive luminal segmentation technique was the most time-consuming and associated with the highest reproducibility and precision with FFR.  相似文献   

10.
PurposeTo provide guidance on the use of anticoagulant and antithrombotic agents in pediatric patients undergoing interventional radiology procedures.Materials and MethodsA multidisciplinary writing group conducted a comprehensive literature search to identify studies on the topic of interest. Recommendations were developed for procedural risk and medication dosage and withholding. A modified Delphi technique was used to achieve consensus agreement on the recommendations.ResultsA total of 24 studies, including systematic reviews and meta-analyses, randomized controlled trials, and prospective and retrospective cohort studies, were identified as relevant. The expert writing group agreed on procedural risk categorization, laboratory testing thresholds, and medication dosage and withholding recommendations specific to pediatric practice. They additionally described the nuances of anticoagulation in clinical conditions specific to pediatrics.ConclusionsThe Society of Interventional Radiology recommends following the guidance provided in the document when developing multidisciplinary management protocols for anticoagulation and antithrombotic treatment in pediatric patients undergoing interventional radiology procedures.  相似文献   

11.
《Radiography》2020,26(4):e195-e200
IntroductionAdverse events in radiology are quite rare, but they do occur. Radiation safety regulations and the law obligate organizations to report certain adverse events, harm and near misses, especially events related to patients' health and safety. The aim of this study was to describe and analyse incidents related to radiation safety issues reported in Finland.MethodsThe data were collected from incident reports documented by radiology personnel concerning notifications of abnormal events in medical imaging made to the Radiation and Nuclear Safety Authority between 2010 and 2017. During these eight years, 312 reports were submitted. Only events reported from radiology departments were included; nuclear medicine, radiotherapy and animal radiology cases were excluded. The final number of reports was 293 (94%).ResultsThe majority of the 293 approved reports were related to computed tomography (CT, 68.3%) and to X-ray examinations (27.6%). Altogether 82.9% of those irradiated were adults, most of whom were exposed to unnecessary radiation through CT (86.5%), 5.5% were children, and 4.4% pregnant women. The most common effective dose of unnecessary radiation was 1 mSv or less (89.7% of all examinations). The highest effective doses were reported in CT (from under 1 mSv–20 mSv and above). The reasons for the adverse events were incorrect identification (32%), incorrect procedure, site or side (30%); and human errors or errors of knowledge (20%).ConclusionAdverse events occurred especially in CT examinations. It is important to collect and analyse incident data, assess the harmful events, learn from them and aim to reduce adverse events.Implications for practiceThis study emphasizes the need for radiological personnel to obtain evidence-based information on adverse events and focus on training to improve patient safety.  相似文献   

12.
《Radiography》2020,26(3):264-268
ObjectivesFrom December 2019, a novel coronavirus disease named COVID-19 was reported in China. Within 3 months, the World Health Organization defined COVID-19 as a pandemic, with more than 370,000 cases and 16,000 deaths worldwide. In consideration of the crucial role of diagnostic testing during COVID-19, the aim of this technical note was to provide a complete synthesis of approaches implemented for the management of suspected or confirmed COVID-19 patients.Key findingsThe planning of a robust plan to prevent the transmission of the virus to patients and department staff members should be fundamental in each radiology service. Moreover, the speed of spread and the incidence of the pandemic make it necessary to optimize the use of personal protective devices and dedicated COVID-19 equipment, given the limited availability of supplies.ConclusionIn the management of radiographic and CT imaging, staff should take special precautions to limit contamination between patients and other patients or professionals.Implications for practiceAn isolated imaging room should be dedicated to suspected or confirmed COVID-19 cases, including radiography and CT scanners. This paper will provide guidance concerning disposable protective gear to be utilized, as well as on the cleaning and sanitation of radiology room and equipment.  相似文献   

13.
PurposeTo identify and analyze all medical malpractice and product liability lawsuits pertaining to inferior vena cava (IVC) filters published within a well-recognized legal research database.Materials and MethodsLexisNexis, a legal research database, was used to retrieve cases that mentioned harm from IVC filters, or lack thereof, as the cause for legal action. A total of 672 cases were analyzed for type of case (medical malpractice or product liability), filter model implanted, filter complications, court decisions, and settlement payments if any.ResultsOf 95 analyzed cases, 20 (21.1%) were medical malpractice cases and 75 (78.9%) were product liability cases. C.R. Bard was the manufacturer associated with the most lawsuits (n = 41, 48.8%). The most litigious filters were the G2 filter from C.R. Bard (n = 17, 20.2%) and Greenfield filter from Boston Scientific (n = 17). The most common complications were IVC penetration (n = 26, 29.9%), filter migration (n = 26, 29.9%), filter fracture (n = 23, 26.4%), and tilt (n = 16, 18.4%). The number of product liability cases has increased from accounting for 25.0% (2 of 8) of filter lawsuits between 2000 and 2010 to 83.9% (73 of 87) during 2011–2020. Of the 20 medical malpractice claims, 9 (45%) were filed for failure to place a filter. One physician was found liable for filter-related complications by a state court in 2014.ConclusionsThe majority of recent IVC filter–related lawsuits are filed against manufacturers on the basis of product liability claims, with the main litigious filters being the G2 and Greenfield filters. Most cases resulted in rulings for physicians or manufacturers. Some were filed against physicians for filter-related complications or for failure to place an IVC filter.  相似文献   

14.
PurposeTo assess the prevalence of positive conflicts of interest (COI) disclosures in United States–based interventional radiology (IR) research as well as the level of agreement between disclosed financial relationships and Open Payment Data for top-cited image-guided procedure research.Materials and MethodsAll publications in volume 30 (2019) of the Journal of Vascular and Interventional Radiology (JVIR) were reviewed to estimate the prevalence of COI disclosures in IR research. Publications were categorized as primary research, systematic review, or other. The prevalence was subsequently compared across JVIR publication subtypes and categories and on the basis of whether they were device-focused publications using χ2 tests. Additionally, the Web of Science database was searched for the top 10 most cited studies of 10 common image-guided procedures with available U.S. physician payment data. The payments were categorized as historical (>1 year prior to publication) or active (<1 year prior to publication) and compared with the disclosed financial COIs using 1-way analysis of variance.ResultsPositive COI disclosures were present in 114 (29%) of the 397 publications in JVIR volume 30. Positive COI disclosures were most prevalent in standards of practice (50%, P = .01) and more prevalent in device-focused publications (54% vs 23%, P < .01). Among the 396 authors of 100 United States–based top-cited image-guided procedure publications, 383 (97%) failed to disclose at least 1 active financial relationship, with an average of $57,937 in undisclosed payments per publication.ConclusionsCOI are prevalent in IR, similar to other areas of healthcare research, and COI in top-cited image-guided procedure research are often underreported.  相似文献   

15.
PurposeTo evaluate safety and feasibility of distal radial artery (DRA) access for noncoronary interventional radiology procedures.Materials and MethodsAll interventional radiology procedures by means of DRA puncture from July 2017 to August 2018 were retrospectively reviewed. Eighty-two punctures in 56 patients were included, mostly in male patients (84% vs 16%). Mean age was 67.8 years (range, 33.3–87.3 years); mean height was 172 cm (range, 142–190 cm); and mean weight was 83 kg (range, 43–120 kg). Procedural characteristics, technical success, and complication rates were gathered from the medical records and follow-up ultrasound when available. Prerequisites for DRA access were adequate radioulnar collateral circulation, sufficient radial artery diameter, and informed consent in patients initially intended for conventional transradial access.ResultsProcedures included transarterial chemoembolization (n = 34), yittrium-90 pretreatment angiography (n = 21), yittrium-90 administration (transarterial radioembolization; n = 20), and embolization of visceral organs (n = 7). Both 4-Fr (n = 35) and 5-Fr (n = 46) sheaths were used. Technical success of DRA access was 97.6%, with conversion to transfemoral access in 2 cases (2.4%). No major complications were reported as a result of DRA access.ConclusionDRA access is a feasible and safe technique for abdominal interventional radiology embolization procedures. No radial artery occlusion or other major complications were observed in patients who underwent follow-up ultrasound.  相似文献   

16.
PurposeTo assess whether adherence to a postprocedural closeout (PPC) checklist decreases adverse events during image-guided procedures.Materials and MethodsBased on the analysis of prior adverse events related to image-guided procedures, the Radiology Quality Committee developed a PPC checklist. The rates of serious reportable events related to image-guided procedures performed in the radiology department were recorded annually from 2015 to 2021. The rate of adverse events was normalized to the procedure volume in the corresponding periods. The number of patients requiring repeat procedures was recorded. The severity of impact was classified according to the Society of Interventional Radiology Adverse Event Classification System. The annual rates before (2015 and 2016) and after (2017–2021) the implementation of PPC were compared.ResultsSeventy-seven safety reports were identified in image-guided procedures over the study period, of which 43 cases were not related to the PPC, leaving 34 cases for the analysis. Radiology adverse events decreased from 0.069% (14/20,218, 7/y) before PPC implementation to 0.034% (20/58,793, 4/y) after implementation (P = .05, 43% decrease). Radiology repeat procedures decreased from 0.040% (8/20,218, 4/y) before PPC implementation to 0.007% (4/58,793, 0.8/y) after implementation (P = .0033, 80% decrease). Moreover, severity of adverse events decreased (P = .009).ConclusionsImplementation of a PPC checklist improved patient outcomes by decreasing the number of adverse events that occur from inadequate safety processes at the end of image-guided procedures by 43%, need for repeat procedures by 80%, and severity of impact of errors.  相似文献   

17.
PurposeTo analyze the impact of physician-specific equipment preference on cost variation for procedures typically performed by interventional radiologists at a tertiary care academic hospital.Materials and MethodsFrom October 2017 to October 2019, data on all expendable items used by 9 interventional radiologists for 11 common interventional radiology procedure categories were compiled from the hospital analytics system. This search yielded a final dataset of 44,654 items used in 2,121 procedures of 11 different categories. The mean cost per case for each physician as well as the mean, standard deviation, and coefficient of variation (CV) of the mean cost per case across physicians were calculated. The proportion of spending by item type was compared across physicians for 2 high-variation, high-volume procedures. The relationship between the mean cost per case and case volume was examined using linear regression.ResultsThere was a high variability within each procedure, with the highest and the lowest CV for radioembolization administration (56.6%) and transjugular liver biopsy (4.9%), respectively. Variation in transarterial chemoembolization cost was mainly driven by microcatheters/microwires, while for nephrostomy, the main drivers were catheters/wires and access sets. Mean spending by physician was not significantly correlated with case volume (P =.584).ConclusionsPhysicians vary in their item selection even for standard procedures. While the financial impact of these differences vary across procedures, these findings suggest that standardization may offer an opportunity for cost savings.  相似文献   

18.
《Radiography》2021,27(4):1038-1043
IntroductionThe use of fluoroscopy-assisted surgical procedures has been increasing recently. The extensive use of fluoroscopy, combined with the lack of knowledge about radiation risks among operating room (OR) personnel (surgeons, anaesthetists, nurses, and radiographers), may lead to misconceptions. The perceptions and beliefs of any health professional concerning radiation protection safety (RPS) may affect their behaviour during surgery, leading to negative outcomes. The aim of this study was to construct a new, original, reliable, and valid instrument to record the beliefs, perceptions, and behaviours of health professionals during surgery, which reflects the established culture of RPS.MethodsA questionnaire was designed, consisting of 95 questions grouped into six coherent sections. The study was performed at a Greek public hospital with a high workload in terms of fluoroscopically guided surgical operations.ResultsIt was distributed among 136 people, and 132 completed questionnaires were collected (response rate 97%). Exploratory factor analysis was performed separately for each scale studied and Cronbach's Alpha reliability analysis was also performed. The reliability of the greater part of the new measurement tool ranged from very good to acceptable.ConclusionThe questionnaire developed in this study is a valid and reliable option for recording health professionals’ perceptions, beliefs, and behaviours concerning the RPS culture.Implications for practiceThis study helps clinical radiographers to understand a possible knowledge gap about RPS and locates the specific fields that the OR personnel misunderstand. It also can support and establish local learning organisations with regular targeted staff training for health professionals, thereby leading to a generally improved RPS culture.  相似文献   

19.
PurposeTo assess the utility of routine preprocedural bloodwork during elective removal of central venous access devices (CVADs) with respect to bleeding complications.Materials and MethodsPatients who underwent removal of a CVAD (tunneled central venous catheter [CVC] or port) by the interventional radiology service between January 2009 and December 2013 were retrospectively reviewed. Removals for infection or malfunction, without preprocedural bloodwork, with another concurrent procedure at the time of CVAD removal, or in patients with a bleeding dyscrasia were excluded. Peripherally inserted central catheter removals and temporary CVAD removals were also excluded. Routine preprocedural bloodwork included hemoglobin, platelet count, partial thromboplastin time, and International Normalized Ratio. Postprocedural complications were classified according to the Society of Interventional Radiology clinical practice guidelines.ResultsThere were 802 CVAD removals in 777 patients (351 female, 426 male). Average patient age was 8.6 years (range, 5 wk to 19 y). In total, 246 permanent CVCs and 556 ports were removed. A total of 802 cases had preprocedural bloodwork. Of the 49 patients who had a bleeding complication after the procedure (6.1%; 49 of 802), 44 had normal findings on preprocedural bloodwork and 5 had abnormal findings. There was no statistically significant difference in bleeding complications between those with normal and abnormal bloodwork results (P = .7740).ConclusionsRoutine bloodwork is not necessary before elective CVAD removal in children without a bleeding dyscrasia. Most children have normal findings on preprocedural bloodwork, and the incidence of postprocedural bleeding is low and not determined by bloodwork results.  相似文献   

20.
PurposeTo evaluate the prevalence of surface lead-dust contamination on radiation protection apparel (RPAs) in the radiology department and compare findings with those from other studies of RPA lead-dust contamination.Materials and MethodsA survey of RPAs was conducted between June and December 2021 in radiology departments at a tertiary-care university hospital. A convenience sample of RPAs located on wall-mounted racks outside the angiography suite and emergency department was surveyed. Surface lead dust on RPAs was detected using a rapid qualitative test.ResultsA total of 69 RPAs included full-length frontal lead aprons (n = 11), full-length frontal lead aprons (n = 25) with thyroid collars (n = 25), and thyroid collars alone (n = 8). Garments consisted mainly of a lead/antimony composite core with a 0.5-mm lead equivalency. One RPA failed radiologic quality inspection, and 8 garments were in poor or worn condition. The overall prevalence of surface lead-dust contamination on RPAs was 60.9% (95% CI, 49.1%–71.5%) and was significantly (P = .0035) higher on thyroid collars (78.8% [95% CI, 62.2%–89.3%]) than on lead aprons (44.4% [95% CI, 29.5%–60.4%]).ConclusionsA high prevalence of surface lead-dust contamination was detected on RPAs using a rapid qualitative test. There is currently no established safe level of lead, and these findings suggest RPAs be monitored frequently not only for physical defects limiting radiation protection but also for lead-dust contamination.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号