首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
PurposeTo explore the hypothesis that central venous stenosis/obstructions (CVS/O) in children are influenced by prior central venous access devices (CVADs) and are associated with future risk for thromboses.Material and MethodsA convenience sample of 100 patients with abnormal venography (stenosis, collaterals, occlusions) documented during peripherally inserted central catheter (PICC) placements were identified from consecutive PICC placements (January 2008 to November 2012). The patients (41 males, 59 females, median age 2.7 years, median weight 11 kg) were categorized based on venographic presence (Group A, n = 53) or absence (Group B, n = 47) of visible connection to the superior vena cava. Each patient’s CVAD history, before and after venography, was analyzed (until October 2016).ResultsBefore venogram, Group B patients were associated with a higher number of previous CVADs, larger diameter devices, greater incidence of malposition, and more use of polyurethane catheters than Group A patients (P < .001). An ipsilateral PICC was successfully placed in 98% of Group A, compared to 32% of Group B (P < .001). After venogram, significantly more Doppler ultrasounds (DUS) were performed and thromboses diagnosed in Group B (57% and 36%) compared to Group A (21% and 8%) (P < .003; P = .001), respectively.ConclusionsPrevious catheter characteristics influenced the severity of venographic changes of CVS/O (Group B). Group B was associated with more subsequent symptomatic thromboses. This information may assist parents and referring physicians to anticipate potential adverse sequelae from CVS/O on the child’s venous health.  相似文献   

2.
PurposeTo compare the effectiveness and safety of percutaneous transluminal angioplasty and peripherally inserted central catheter (PTA + PICC), contralateral PICC, and midline catheterization (MC) in patients with venous stenosis.Materials and MethodsA total of 7,327 PICC procedures were performed in 5,421 patients at a single institution between 2013 and 2019. Among them, 87 patients had upper-arm venous stenoses and were managed with PTA + PICC, contralateral PICC, or MC. Data on catheter-dwell time, clinical success rate, and adverse events were recorded. The procedure was considered to have clinically succeeded when a PICC was removed from the patient just before discharge or after the completion of therapy. Catheter survival time and the chance of adverse events were compared among the groups using the Kaplan-Meier method and log-rank test.ResultsPTA + PICC, contralateral PICC, and MC procedures were performed for 57 (65.5%, 57/87), 10 (11.5%, 10/87), and 20 (23.0%, 23/87) patients, respectively. The mean catheter-dwell time in the PTA + PICC, contralateral PICC, and MC groups was 49.7, 28.7, and 15.1 days, respectively, and the clinical success rate of each group was 86.0% (49/57), 80.0% (8/10), and 50.0% (10/20). The PTA + PICC group had a significantly longer catheter survival time than the MC group (P < .001). The chance of a catheter-related infection (P = .008) was significantly lower in the PTA + PICC group than in the MC group.ConclusionsPTA + PICC or contralateral PICC should be considered prior to ipsilateral MC when venous stenosis is encountered during PICC procedures.  相似文献   

3.
PurposeTo evaluate dislodgement of tunneled dialysis catheters (TDCs) in de novo (DN) placement with ultrasound versus over-the-wire exchange (OTWE).Materials and MethodsData were collected retrospectively on all TDC placements at this institution from 2001 to 2019 and were excluded if no removal date was recorded or if dwell time was more than 365 days. Information on TDC brand, placement, insertion/removal, and removal reason were collected. Multiple logistic regression evaluated factors associated with TDC dislodgement. DN placement and OTWE were compared for rate of dislodgement (generalized estimating equations method) and TDC dwell time (survival analysis).ResultsIn total, 5328 TDCs were included with 66% (3522) placed DN and 32% (1727) via OTWE. Mean dwell time was 65 ± 72 days, and dislodgement occurred in 4% (224). TDC dislodgement rates in the DN and OTWE groups were 0.48 and 0.93 per 1000 catheter days, respectively. Brand (Ash Split vs. VectorFlow), placement technique (OTWE vs. DN), laterality (left vs. right), and site (left vs. right internal jugular vein) were significant predictors of dislodgement. OTWE placement exhibited 1.7 times the odds of dislodgement (95% confidence interval, 1.2–2.6; P = .004) compared to DN and had significantly higher probability of dislodgement across time (hazard ratio = 2.0; P < .001) compared to DN. Dislodgement rates for OTWE vs. DN were 8% vs. 3% (3 months), 13% vs. 6% (6 months), and 38% vs. 17% (1 year).ConclusionsTDC spontaneous dislodgement rates were significantly and consistently higher after OTWE compared to DN placement. These data support more careful attention to catheter fixation after OTWE placement.  相似文献   

4.
PurposeTo compare the cost and outcomes of surgical and interventional radiology (IR) placement of totally implantable venous access devices (TIVADs) within a large regional health system to determine the service line with better outcomes and lower costs to the health system.Materials and MethodsA retrospective review of all chest port placements performed in the operating room (OR) and IR suite over 12 months was conducted at a large, integrated health system with 6 major hospitals. Secondary electronic health record and cost data were used to identify TIVAD placements, follow-up procedures indicating port malfunction, early adverse events (within 1 month after the surgery), late adverse events (2–12 months after the procedure), and health system cost of TIVAD placement and management.ResultsFor 799 total port placements included in this analysis, the rate of major adverse events was 1.3% and 1.9% for the IR and OR groups, respectively, during the early follow-up (P = .5655) and 4.9% and 2.8% for the IR and OR groups, respectively, during the late follow-up (P = .5437). Malfunction-related follow-up procedure rates were 1.8% and 2.6% for the IR and OR groups, respectively, during the early follow-up (P = .4787) and 12.4% and 10.5% for the IR and OR groups, respectively, during the late follow-up (P = .4354). The mean cost of port placement per patient was $4,509 and $5,247 for the IR and OR groups, respectively. The difference in per-patient cost of port placement was $1,170 greater for the OR group (P = .0074).ConclusionsThe similar rates of adverse events and follow-up procedures and significant differences in insertion cost suggest that IR TIVAD placement may be more cost effective than surgical placement without affecting the quality.  相似文献   

5.
PurposeTo compare clinical characteristics and treatment outcomes of intra-arterial thrombectomy (IAT) in acute basilar artery occlusion (BAO) with and without underlying intracranial atherosclerotic stenosis (ICAS) and to investigate the usefulness of preprocedural CT angiography findings in the diagnosis of ICAS.Materials and MethodsTwenty patients who received IAT for acute BAO between September 2014 and March 2019 were included. Additional therapies such as angioplasty, stent placement, and tirofiban infusion were provided while treating ICAS. Clinical and angiographic results of treatment were recorded. Preprocedural CT angiography findings in ICAS and non-ICAS groups were compared to assess (i) basilar tip opacification, (ii) partial occlusion, (iii) presence of convex border, (iv) occlusion segment longer than two thirds of the basilar artery or 20 mm, (v) dense basilar artery, and (vi) wall calcification in the occluded segment.ResultsAmong the 20 patients (mean age, 71.3 y; mean stroke score, 24.8), optimal recanalization was achieved in 19 (95%). Three patients had good clinical outcomes. There were 6 patients with underlying ICAS. No difference was observed between ICAS and non-ICAS groups in terms of optimal angiographic recanalization and good outcome. On CT angiography, basilar tip occlusion (100% vs 29%), partial occlusion (100% vs 83%), and long occlusion length (100% vs 14%) significantly differed between the groups (P ≤ .01).ConclusionsIn acute BAO, underlying ICAS does not affect optimal recanalization rate or clinical outcome. Preprocedural CT angiography is a potentially useful tool to detect it.  相似文献   

6.
PurposeTo evaluate ultrasound-accelerated, catheter-directed thrombolysis (CDT) for treatment of acute submassive pulmonary embolism (PE).Materials and MethodsThis single-center, retrospective study included patients who underwent CDT for acute submassive PE (N = 113, 52% men/48% women) from 2013 to 2017. Baseline characteristics included history of deep venous thrombosis (12%), history of PE (6%), and history of cancer (18%). Of cohort patients, 88% (n=99) had a simplified PE severity index score of ≥ 1 indicating a high risk of mortality.ResultsA technical success rate of 100% was achieved with 84% of patients having bilateral catheter placements. Average tissue plasminogen activator (tPA) therapy duration was 20.7 hours ± 1.5, and median tPA dose was 21.5 mg. Three patients (2.6%) experienced minor hemorrhagic complications. Mean hospital length of stay was 6 days. Mean pulmonary arterial pressure decreased from 55 mm Hg on presentation to 37 mm Hg (P < .01) 1 day following initiation of thrombolytic therapy. All-cause mortality rate of 4% (n = 4) was noted on discharge, which increased to 6% (n = 7) at 6 months. At 6-month follow-up compared with initial presentation, symptom improvements (93%), physiologic improvements (heart rate 72 beats/min vs 106 beats/min, P < .01), oxygen requirement improvements (fraction of inspired oxygen 20% vs 28%, P < .01), and right ventricular systolic pressure improvements by echocardiography (30 mm Hg vs 47 mm Hg, P < .01) were observed.ConclusionsCDT for acute submassive PE was associated with low complications and mortality, decreased right ventricular systolic pressure, high rates of clinical improvement, and improved intermediate-term clinical outcomes.  相似文献   

7.
PurposeTo evaluate the safety of outpatient percutaneous endovascular abdominal aortic repair (PEVAR) versus inpatient PEVAR without or with adjunct procedures.Materials and MethodsBetween January 2012 and June 2019, a cohort of 359 patients comprising 168 (46.8%) outpatients and 191 (53.2%) inpatients who had undergone PEVAR were enrolled. All the patients were asymptomatic but had indications for endovascular aortic repair, ie, fit for intravenous anesthesia and anatomically feasible with standard devices. Patient sex, age, comorbidities, smoking status, type of anesthesia, adjunct procedures, type of graft device, operative times, mortality, complications, and readmissions were analyzed.ResultsMedian follow-up period was 16.5 months (interquartile range, 9–31 months). Except for a higher percentage of tobacco use (42.6% vs 28.8%; P = .04), dyslipidemia (39.7% vs 19.2%; P < .01), and use of local anesthesia (99.4% vs 82.2%; P < .01) in the outpatients, there was no significant difference in the type of graft and adjunct procedures used. No outpatient mortality occurred. There was no difference in the number, severity, and onset of complications (all P > .05). Outpatient unexpected same-day admission, 30-day readmission, and emergency department visit rates were 4.8%, 2.4% (P = .13), and 10% (P < .01), respectively. Operative times for outpatient PEVAR without adjunct procedures were shorter (P < .01).ConclusionsOutpatient PEVAR can be performed with a safety profile similar to that of inpatient PEVAR. The unexpected same-day admission, 30-day readmission, and emergency department visit rates were low. The outpatient PEVARs without adjunct procedures took less time.  相似文献   

8.
PurposeTo compare electromagnetic navigation (EMN) with computed tomography (CT) fluoroscopy for guiding percutaneous biopsies in the abdomen and pelvis.Materials and MethodsA retrospective matched-cohort design was used to compare biopsies in the abdomen and pelvis performed with EMN (consecutive cases, n = 50; CT-Navigation; Imactis, Saint-Martin-d’Hères, France) with those performed with CT fluoroscopy (n = 100). Cases were matched 1:2 (EMN:CT fluoroscopy) for target organ and lesion size (±10 mm).ResultsThe population was well-matched (age, 65 vs 65 years; target size, 2.0 vs 2.1 cm; skin-to-target distance, 11.4 vs 10.7 cm; P > .05, EMN vs CT fluoroscopy, respectively). Technical success (98% vs 100%), diagnostic yield (98% vs 95%), adverse events (2% vs 5%), and procedure time (33 minutes vs 31 minutes) were not statistically different (P > .05). Operator radiation dose was less with EMN than with CT fluoroscopy (0.04 vs 1.2 μGy; P < .001), but patient dose was greater (30.1 vs 9.6 mSv; P < .001) owing to more helical scans during EMN guidance (3.9 vs 2.1; P < .001). CT fluoroscopy was performed with a mean of 29.7 tap scans per case. In 3 (3%) cases, CT fluoroscopy was performed with gantry tilt, and the mean angle out of plane for EMN cases was 13.4°.ConclusionsPercutaneous biopsies guided by EMN and CT fluoroscopy were closely matched for technical success, diagnostic yield, procedure time, and adverse events in a matched cohort of patients. EMN cases were more likely to be performed outside of the gantry plane. Radiation dose to the operator was higher with CT fluoroscopy, and patient radiation dose was higher with EMN. Further study with a wider array of procedures and anatomic locations is warranted.  相似文献   

9.
PurposeTo compare the direct bundled costs of interventional radiology (IR) suite versus bedside placement of noncuffed central venous catheters in infants.MethodsA single-center retrospective review was performed of all noncuffed upper extremity (peripherally inserted central venous catheter [PICC]) and tunneled femoral (tunneled femoral central venous catheter [TCVC]) catheters placed in infants between January 1, 2018, and December 31, 2018. Propensity score matching was performed adjusting for age, birth weight, procedure weight, and catheter days. Process maps for each procedure were created based on location and sedation type. Technical success and complications were recorded for each placement. The total direct bundled cost for each catheter placement was calculated by summing the procedure and complication costs.ResultsA total of 142 procedures were performed on 126 matched patients with a technical success of 96% at the bedside and 100% in the IR suite (P = .08). The complication rates did not significantly differ between the 2 groups (P = .51). The total direct bundled costs for catheter placement were $1421.3 ± 2213.2 at the bedside and $2256.8 ± 3264.7 in the IR suite (P = .001).ConclusionsThe bundled cost of bedside femoral catheter placement is significantly less than that of fluoroscopic TCVC and PICC placement performed in the IR suite, mainly related to differences in sedation costs.  相似文献   

10.
《Radiography》2023,29(1):38-43
IntroductionChest X-rays (CXR) with under-exposure increase image noise and this may affect convolutional neural network (CNN) performance. This study aimed to train and validate CNNs for classifying pneumonia on CXR as normal or pneumonia acquired at different image noise levels.MethodsThe study used the curated and publicly available “Chest X-Ray Pneumonia” dataset of 5856 AP CXR classified into 1583 normal, 4273 viral and bacterial pneumonia cases. Gaussian noise with zero mean was added to the images, at 5 image noise variance levels, corresponding to decreasing exposure. Each noise-level dataset was split into 80% for training, 10% for validation, and 10% for test data and then classified using custom trained sequential CNN architecture. Six classification tasks were developed for five Gaussian noise levels and the original dataset. Sensitivity, specificity, predictive values and accuracy were used as evaluation performance metrics.ResultsCNN evaluation on the different datasets revealed no performance drop from the original dataset to the five datasets with different noise levels. Sensitivity, specificity and accuracy for the normal datasets were 98.7%, 76.1% and 90.2%. For the five Gaussian noise levels the sensitivity, specificity and accuracy ranged from 96.9% to 98.2%, 94.4%–98.7% and 96.8%–97.6%, respectively. A heat map was used for visual explanation of the CNNs.ConclusionThe CNNs sensitivity maintained, and the specificity increased in distinguishing between normal and pneumonia CXR with the introduction of image noise.Implications for practiceNo performance drops of CNNs in distinguishing cases with and without pneumonia CXR with different Gaussian noise levels was observed. This has potential for decreasing radiation dose to patients or maintaining exposure parameters for patients that require additional radiographs.  相似文献   

11.
PurposeTo compare the technical success of antegrade uteral stent (AUS) and retrograde ureteral stent (RUS) placements in patients with malignant ureteral obstruction (MUO) and to determine the predictors of technical failure of RUS.Materials and MethodsThis study retrospectively included 61 AUS placements (44 patients) performed under fluoroscopic guidance and 76 RUS placements (55 patients) performed under cystoscopic guidance in patients with MUO from January 2019 to December 2020. Technical success rates of the 2 techniques were compared using inverse probability of treatment weighting (IPTW) analysis. Logistic regression was used to identify predictive factors for technical failures.ResultsTechnical success was achieved in 98.4% of the AUS group and 47.4% of the RUS group. After stabilized IPTW, the technical success rate was higher in the AUS group than in the RUS group (adjusted risk difference, 49.4%; 95% confidence interval [CI], 35.4%–63.1%). The independent predictors for technical failure of the RUS procedure were age of ≥65 years (odds ratio [OR], 5.56; 95% CI, 1.73–21.27), ureteral orifice invasion (OR, 4.21; 95% CI, 1.46–13.46), and extrinsic cancer (OR, 15.58; 95% CI, 2.92–111.81).ConclusionsThe technical success rate of AUS placement was higher than that of RUS placement in patients with MUO. RUS failure was associated with age of ≥65 years, cancer with ureteral orifice invasion, and extrinsic ureteral obstruction.  相似文献   

12.
PurposeTo evaluate the feasibility of a new technique for imaging-guided de novo retrograde ureteral double J (DJ) stent placement without cystoscopy in women.Materials and MethodsEighty-four women referred for ureteral stent placement between April 2019 and January 2022 were included. In all the patients, the initial attempt for stent placement was performed in a retrograde fashion. Successful ureteral catheterization and DJ stent placement were considered as technical success. The fluoroscopy time required to catheterize the ureter and that for the entire procedure were recorded. Factors affecting the technical success rate and fluoroscopy time were examined.ResultsA total of 108 ureteral stent placement procedures in 84 women, with a mean age of 57.5 years (range, 19–85 years), were performed. The most common underlying pathologies were cervical (n = 33, 31%) and ovarian (n = 32, 30%) carcinomas. The most commonly involved segments of the ureter were the lower half (n = 44, 40%) and trigone (n = 39, 36%). The technical success rate was 81.5%, and it reached 93% in the case of lower-half ureteral obstruction. Distorted trigonal anatomy caused by external compression of the bladder wall by a mass was associated with a higher rate of technical failure (90.6% vs 47.8%; P < .001). The use of ultrasound guidance to guide the sheath to the ureteral orifice allowed for a significant decrease in the fluoroscopy time for ureteral catheterization (4.6 minutes ± 3.91 vs 2.26 minutes ± 2.32; P = .003) and that for the entire procedure (9.42 minutes ± 4.95 vs 5.93 minutes ± 4.06; P = .001).ConclusionsImaging-guided de novo retrograde ureteral catheterization and stent placement can be successfully performed in a high percentage of patients within a reasonable fluoroscopy time without the need for cystoscopy in women.  相似文献   

13.
PurposeTo systematically investigate artifacts produced by biopsy and ablation needles imaged at various trajectories with respect to the static magnetic field (B0).Materials and MethodsAn acrylic phantom was scanned using a rapid balanced fast field echo sequence with 3.0-T magnetic resonance imaging. A 15-gauge microwave needle, a 17-gauge cryoneedle, and an 18-gauge coaxial biopsy needle were imaged in sagittal and axial planes, in 7 different orientations to B0 (0°, 15°, 30°, 45°, 60°, 75°, and 90°). For 4 angles (15°, 30°, 60°, and 75°), images were acquired with the slice orientation aligned to the needle angulation, resulting in the frequency encoding direction being parallel to the needle’s long axis for the sagittal slice and perpendicular to the needle angulation for the axial acquisition. The artifact length at the needle tip and maximum artifact width were recorded.ResultsNo significant difference was noted in mean artifact length for the cryoneedle (13 mm; 95% confidence interval [CI], 7–19) and coaxial biopsy needle (8 mm; 95% CI, 5–10; P = .08). The mean artifact length was significantly smaller for the microwave ablation needle (1 mm; 95% CI, 0–2; P < .05). The mean artifact width was highest for the coaxial needle (17 mm; 95% CI, 14–19) and significantly higher than the cryoneedle (12 mm; 95% CI, 10–15; P = .024) and microwave ablation needle (8 mm; 95% CI, 6–10; P < .01). The needle tip artifact was significantly smaller when the slice orientation was aligned to the needle angulation for the coaxial and cryoablation needles (P < .01).ConclusionsNeedle tip artifact length and width increase with increasing angulation to the static field. At large angles (>15°), the needle tip position can be predicted better from images acquired when the slice orientation is aligned to the needle’s angulation.  相似文献   

14.
PurposeTo investigate whether intra-arterial injection of lidocaine enhances irreversible electroporation (IRE) in a liver model.Materials and MethodsConventional IRE (C-IRE) and lidocaine-enhanced IRE (L-IRE) were performed in 8 pig livers. Protocol 1 (tip exposure and electrode distance of 2.0 cm each) and protocol 2 (increased tip exposure and electrode distance 2.5 cm each) were used. Animals were sacrificed 3 hours after IRE. Study goals included electrical tissue properties (eg, current, conductivity) during IRE, geometry of IRE zones analyzed using computed tomography and magnetic resonance imaging (eg, volume and sphericity index), degree of acute liver damage, and irreversible cell death analyzed using microscopy (hematoxylin and eosin staining and terminal deoxynucleotidyl transferase deoxyuridine 5-triphosphate nick end labeling). Statistical comparisons were performed using the paired t test and Wilcoxon test.ResultsAll treatments were performed without adverse events. Electrical tissue properties were not significantly different between C-IRE and L-IRE. For protocol 1, the diameter of the largest sphere within the IRE zone was significantly larger for L-IRE than for C-IRE (25.0 ± 4.7 mm vs 18.4 ± 3.1 mm [P = .013]). For protocol 2, the volume of IRE zone was significantly larger for L-IRE compared with C-IRE (46.0 ± 5.4 cm3 vs 22.6 ± 6.4 cm3 [P = .018]), as well as the diameter of the largest sphere within the IRE zone (27.1 ± 2.2 mm vs 19.8 ± 2.3 mm [P = .020]). For protocol 1, a significantly higher degree of irreversible cell death was noted for L-IRE than for C-IRE (1.8 ± 1.0 vs 0.8 ± 1.0 [P = .046]).ConclusionsIntra-arterial injection of lidocaine can enhance IRE in terms of larger IRE zones and an increase of irreversible cell death.  相似文献   

15.
PurposeTo assess use of stereotactic body radiotherapy (SBRT) for stage I renal cell carcinoma (RCC) and compare outcomes with thermal ablation and partial nephrectomy (PN).Materials and MethodsThe 2004–2015 National Cancer Database was investigated for histopathologically proven stage I RCC treated with PN, cryoablation, radiofrequency (RF) or microwave (MW) ablation, or SBRT. Patients were propensity score–matched to account for potential confounders, including patient age, sex, race, comorbidities, tumor size, histology, grade, tumor sequence, administration of systemic therapy, treatment in academic vs nonacademic centers, treatment location, and year of diagnosis. Overall survival (OS) was evaluated with Kaplan-Meier plots, log-rank tests, and Cox proportional hazards models.ResultsA total of 91,965 patients were identified (SBRT, n = 174; PN, n = 82,913; cryoablation, n = 5,446; RF/MW ablation, n = 3,432). Stage I patients who received SBRT tended to be older women with few comorbidities treated at nonacademic centers in New England states. After propensity score matching, a cohort of 636 patients was obtained with well-balanced confounders between treatment groups. In the matched cohort, OS after SBRT was inferior to OS after PN and thermal ablation (PN vs SBRT, hazard ratio [HR] = 0.29, 95% confidence interval [CI] 0.19–0.46, P < .001; cryoablation vs SBRT, HR = 0.40, 95% CI 0.26–0.60, P < .001; RF/MW ablation vs SBRT, HR = 0.46, 95% CI 0.31–0.67, P < .001). Compared with PN, neither cryoablation nor RF/MW ablation showed significant difference in OS (cryoablation vs PN, HR = 1.35, 95% CI 0.80–2.28, P = .258; RF/MW ablation vs PN, HR = 0.64, 95% CI 0.95–2.55, P = .079).ConclusionsCurrent SBRT protocols show lower OS compared with thermal ablation and PN, whereas thermal ablation and PN demonstrate comparable outcomes.  相似文献   

16.
PurposeTo report the device performance and safety for the Surfacer Inside-Out access catheter system in patients with thoracic central venous obstruction (TCVO) requiring central venous access (CVA).Materials and MethodsFive sites prospectively enrolled 30 patients requiring a tunneled dialysis catheter between February 2017 and September 2018 in the SAVE (Surfacer System to Facilitate Access in Venous Obstructions) registry. Patient demographics, medical history, and type of TCVO were documented at enrollment. Device performance and adverse events were collected during the procedure and upon hospital discharge. Twenty-nine of the 30 patients enrolled required CVA for hemodialysis. Retrospective classification of TCVOs according to SIR reporting standards showed 9 patients (30%) had Type 4 obstructions, 8 (26.7%) had Type 3, 5 (16.7%) had Type 2, and 8 (26.7%) had Type 1 obstruction.ResultsCentral venous catheters (CVCs) were successfully placed in 29 of 30 patients (96.7%). The procedure was discontinued in 1 patient due to vascular anatomical tortuosity. All 29 patients with successful CVC placement achieved adequate catheter patency and tip positioning. There were no device-related adverse events, catheter malposition, or intra- or postprocedural complications. Mean time from device insertion to removal for the 29 patients who successfully completed the procedure was 24 ± 14.9 (range, 6–70) minutes. Mean fluoroscopy time was 6.8 ± 4.5 (range, 2.2–25.5) minutes.ConclusionsThe Surfacer Inside-Out procedure provided an alternative option to restore right-sided CVA in patients with TCVO.  相似文献   

17.
PurposeThe association between occupational radiation exposure and endothelium-dependent vasodilation (EDV) remains unclear. This study evaluated the association between radiation exposure and EDV among fluoroscopy-guided interventional procedure specialists and explored the possible mechanisms.Materials and MethodsBrachial flow-mediated dilation was compared in 21 interventional cardiologists (the radiation group) and 15 noninterventional cardiologists (the nonradiation group). Animal radiation experiments were also performed to observe the impact of radiation on EDV.ResultsFlow-mediated dilation in both the left (radiation group, 3.63% vs. nonradiation group, 6.77%; P < .001) and right brachial arteries (5.36% vs. 7.33%, respectively; P = .04) and serum nitric oxide (NO) level (343.69 vs. 427.09 μmol/L, respectively; P = .02) were significantly reduced in the radiation group compared to those in the nonradiation group. EDV was significantly impaired in acetylcholine concentrations of 3 × 10−6 mol/L and 10−5 mol/L (60.09% vs.74.79%, respectively; P = .03; and 62.73% vs. 80.56%, respectively; P = .002), and reactive oxygen species levels in the aorta intima and media layers were significantly increased in mice after a single x-ray exposure, which could be partly rescued by pretreatment with folic acid (P < .05).ConclusionsRadiation exposure can lead to impairment of flow-mediated vasodilation in human or EDV in mice. In mice acutely exposed to radiation, folic acid alleviated radiation-induced EDV impairment by possible reduction of reactive oxidative species.  相似文献   

18.
PurposeTo compare the safety and effectiveness of transarterial radioembolization (TARE) and transarterial chemoembolization with drug-eluting embolic agents combined with percutaneous ablation (transarterial chemoembolization [TACE] + ablation) in the treatment of treatment-naïve, unresectable, solitary hepatocellular carcinoma (HCC) of ≥3 cm.Materials and MethodsTwenty-nine patients with treatment-naïve, unresectable, solitary HCC of ≥3 cm received combined TACE + ablation, and 40 patients received TARE at a single institution. Local tumor response, tumor progression-free survival (PFS), overall survival, need for reintervention, bridge to transplant, and major complications were compared. Clinical variables and outcomes were compared before and after propensity score matching (PSM).ResultsBefore PSM, patients who underwent TARE had a larger tumor size (3.7 vs 5.5 cm; P = .0005) and were older (61.5 vs 69.3 years; P = .0014). After PSM, there was no difference in baseline characteristics between the 2 groups, with the mean tumor sizes measuring 3.9 and 4.1 cm in the TACE + ablation and TARE cohorts, respectively. After PSM (n = 19 in each group), no statistically significant difference was observed in local radiological response (disease control rates, 100% vs 94.7%; P = .31), survival (subdistribution hazard ratio [SHR], 0.71; 95% confidence interval [CI], 0.28–1.80; P = .469), PFS (SHR, 0.61; 95% CI, 0.21–1.71; P = .342), bridge to transplant (21.1% vs 31.6%, P = .46), and major adverse event rates (15.8% vs 10.5%, P = .63) between the 2 groups. The mean total number of locoregional interventions was higher in the TACE + ablation cohort (1.9 vs 1.3 sessions, P = .02), with an earlier median reintervention trend (SHR, 0.61; 95% CI, 0.20–1.32; P = .167).ConclusionsThe present study showed that TARE and the combination of TACE and ablation are comparable in safety and effectiveness for treating treatment-naïve, unresectable, solitary HCC of ≥3 cm.  相似文献   

19.
PurposeTo determine the impact of port and catheter tip cultures on the clinical management of port-related infections.Materials and MethodsPatients whose ports were removed for infection between January 2016 and December 2019 were retrospectively identified. The study sample included 68 ports removed for suspected catheter-related bloodstream infection (CRBSI) and 27 ports removed for local infection. Port surface, catheter tip, and blood culture results were recorded. Antimicrobial therapy before and after port removal was recorded. The impact of culture results on port infection management was determined.ResultsOf the 68 ports removed from patients with CRBSI, 78% received empiric antibiotics. Of these patients, blood cultures led to a change in therapy in 77%. Catheter tip cultures were positive in 32% whereas port surface cultures were positive in 53% of patients. Culture results did not influence antimicrobial therapy in any patient with CRBSI. Of 27 port removals performed for local infection, catheter tip cultures were positive in 41% whereas port surface cultures were positive in 59% of patients. Port surface cultures led to a change in therapy in 33% of local infections. Port surface cultures were significantly more likely to impact management if removal was performed for local infection than for CRBSI (33% vs. 0%, respectively; P < .001). Port surface cultures were inclusive of all positive catheter tip cultures.ConclusionsFor patients with suspected CRBSI, blood cultures alone are sufficient to guide therapy. Port cultures may be justified in the setting of local infection. Catheter tip cultures are unnecessary if port surface cultures are performed.  相似文献   

20.
PurposeTo study the feasibility, safety, and effectiveness of microwave ablation (MWA) in patients with multifocal papillary thyroid microcarcinoma (PTMC).Materials and MethodsThis retrospective study included patients who underwent MWA for multifocal PTMC (number of nodules ≤3). A total of 44 patients were included, and the mean age was 43 years (SD ± 11). After ablation, progression-free survival (PFS) at 6, 12, 24, 36, and 48 months; disease progression; change in tumor size and volume; tumor disappearance rate; and adverse events (AEs) were assessed, and the feasibility, safety, and effectiveness of MWA for PTMC were evaluated on the basis of statistical analysis.ResultsThe median follow-up period was 18 months (interquartile range, 12–33 months). The PFS rates at 6, 12, 24, 36, and 48 months were 100.0%, 96.4%, 96.4%, 70.3%, and 52.7%, respectively. The disease progression rate was 11.4% (5 of 44 patients). The maximum diameter (MD) and volume of the ablation zone were larger at the 3-month follow-up than before ablation (median MD, 13.0 vs 7.0 mm; P < .001; median volume, 503.8 vs 113.0 mm3; P < .001). Subsequently, the tumors exhibited a reduction in both size and volume after 18 months (median MD, 4.0 vs 7.0 mm; P = .04; median volume, 12.6 vs 113.0 mm3; P = .055). At the end of the follow-up period, the complete response rate was 59% (26 of 44 patients). The overall AE rate was 6.8%.ConclusionsMWA is a feasible treatment for PTMC (number of nodules ≤3), and this study preliminarily demonstrated the safety and effectiveness of this technique.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号