首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
A diffusion imaging method with a tetrahedral sampling pattern has been developed for high-sensitivity diffusion analysis. The tetrahedral gradient pattern consists of four different combinations of x, y, and z gradients applied simultaneously at full strength to uniformly measure diffusion in four different directions. Signal-to-noise can be increased by up to a factor of about three using this approach, compared with diffusion measurements made using separately applied x, y, and z gradients. A mathematical formalism is presented describing six fundamental parameters: the directionally averaged diffusion coefficient D and diffusion element anisotropies η and ε which are rotationally invariant, and diffusion ellipsoid orientation angles θ, ?, and Ψ which are rotationally variant. These six parameters contain all the information in the symmetric diffusion tensor D. Principal diffusion coefficients, reduced anisotropies, and other rotational invariants are further defined. It is shown that measurement of off-diagonal tensor elements is essential to assess anisotropy and orientation, and that the only parameter which can be measured with the orthogonal method is D. In cases of axial diffusion symmetry (e.g., fibers), the four tetrahedral diffusion measurements efficiently enable determination of D, η, θ, and ? which contain all the diffusion information. From these four parameters, the diffusion parallel and perpendicular to the symmetry axis (D1 and D1) and the axial anisotropy A can be determined. In more general cases, the six fundamental parameters can be determined with two additional diffusion measurements. Tetrahedral diffusion sequences were implemented on a clinical MR system. A muscle phantom demonstrates orientation independence of D, D1, D1, and A for large changes in orientation angles. Sample background gradients and diffusion gradient imbalances were directly measured and found to be insignificant in most cases.  相似文献   

2.
It is well known that quantitative anisotropy measurements derived from the diffusion tensor are extremely sensitive to noise contamination. The level of noise in the diffusion tensor imaging (DTI) experiment is usually measured from some estimate of the signal-to-noise ratio (SNR) in the component diffusion-weighted (DW) images. This measure is, however, highly dependent on experimental parameters, such as the diffusion attenuation b-value and the diffusion coefficient of the subject. Conversely, the diffusion-to-noise ratio (DNR), defined as the SNR of the calculated diffusion tensor trace map, provides a reliable estimate of noise contamination, which is largely independent of such parameters. In this work it is demonstrated how reliable anisotropy measurements can be obtained using an image acquisition strategy that optimizes the DNR of the DTI experiment. This acquisition scheme is shown to provide noise-independent measurements of typical diffusion anisotropy values found in the human brain.  相似文献   

3.
Diffusion tensor imaging in evaluation of human skeletal muscle injury   总被引:5,自引:0,他引:5  
PURPOSE: To explore the capability and reliability of diffusion tensor magnetic resonance imaging (DTI) in the evaluation of human skeletal muscle injury. MATERIALS AND METHODS: DTI of four patients with gastrocnemius and soleus muscles injuries was compared to eight healthy controls. Imaging was performed using a GE 3.0T short-bore scanner. A diffusion-weighted 2D spin echo echo-planar imaging (EPI) pulse sequence optimized for skeletal muscle was used. From a series of axially acquired diffusion tensor images the diffusion tensor eigenparameters (eigenvalues and eigenvectors), fractional anisotropy (FA), and apparent diffusion coefficient (ADC) were calculated and compared for injured and healthy calf muscles. Two dimensional (2D) projection maps of the principal eigenvectors were plotted to visualize the healthy and pathologic muscle fiber architectures. RESULTS: Clear differences in FA and ADC were observed in injured skeletal muscle, compared to healthy controls. Mean control FA was 0.23 +/- 0.02 for medial and lateral gastrocnemius (mg and lg) muscles, and 0.20 +/- 0.02 for soleus (sol) muscles. In all patients FA values were reduced compared to controls, to as low as 0.08 +/- 0.02. The ADC in controls ranged from 1.41 to 1.31 x 10(-9) m(2)/second, while in patients this was consistently higher. The 2D projection maps revealed muscle fiber disorder in injured calves, while in healthy controls the 2D projection maps show a well organized (ordered) fiber structure. CONCLUSION: DTI is a suitable method to assess human calf muscle injury.  相似文献   

4.
PURPOSE: To demonstrate the feasibility of in vivo calf muscle fiber tracking in human subjects. MATERIALS AND METHODS: An EPI-based diffusion tensor imaging (DTI) sequence with six-direction diffusion gradient sensitization was implemented, and DT images were acquired at 3 Tesla on five subjects using an extremity coil. The mean diffusivity, fractional anisotropy (FA), and fiber angle (with respect to the magnet z-axis) were measured in different muscles, and fibers were tracked from several regions of interest (ROIs). RESULTS: The fiber orientations in the current DTI studies agree well with those determined in previous spectroscopic studies. The orientation angles ranged from 13.4 degrees in the lateral gastrocnemius to 48.5 degrees in the medial soleus. The diffusion ellipsoid in muscle tissue is anisotropic and approximates a prolate model, as shown by color maps of the anisotropy. Fibers were tracked from the different muscle regions, and the unipennate and bipennate structure of muscle fibers was visualized. CONCLUSION: The study clearly shows that in vivo fiber tracking of muscle fibers is feasible and could potentially be applied to study muscle structure function relationships.  相似文献   

5.
In this work, a multiecho parallel echo‐planar imaging (EPI) acquisition strategy is introduced as a way to improve the acquisition efficiency in parallel diffusion tensor imaging (DTI). With the use of an appropriate echo combination strategy, the sequence can provide signal‐to‐noise ratio (SNR) enhancement while maintaining the advantages of parallel EPI. Simulations and in vivo experiments demonstrate that a weighted summation of multiecho images provides a significant gain in SNR over the first echo image. It is experimentally demonstrated that this SNR gain can be utilized to reduce the number of measurements often required to ensure adequate SNR for accurate DTI measures. Furthermore, the multiple echoes can be used to derive a T2 map, providing additional information that might be useful in some applications. Magn Reson Med 60:1512–1517, 2008. © 2008 Wiley‐Liss, Inc.  相似文献   

6.
A technique suitable for diffusion tensor imaging (DTI) at high field strengths is presented in this work. The method is based on a periodically rotated overlapping parallel lines with enhanced reconstruction (PROPELLER) k-space trajectory using EPI as the signal readout module, and hence is dubbed PROPELLER EPI. The implementation of PROPELLER EPI included a series of correction schemes to reduce possible errors associated with the intrinsically higher sensitivity of EPI to off-resonance effects. Experimental results on a 3.0 Tesla MR system showed that the PROPELLER EPI images exhibit substantially reduced geometric distortions compared with single-shot EPI, at a much lower RF specific absorption rate (SAR) than the original version of the PROPELLER fast spin-echo (FSE) technique. For DTI, the self-navigated phase-correction capability of the PROPELLER EPI sequence was shown to be effective for in vivo imaging. A higher signal-to-noise ratio (SNR) compared to single-shot EPI at an identical total scan time was achieved, which is advantageous for routine DTI applications in clinical practice.  相似文献   

7.
Diffusion MRI is a useful imaging technique with many clinical applications. Many diffusion MRI studies have utilized echo-planar imaging (EPI) acquisition techniques. In this study, we have developed a rapid diffusion-prepared fast imaging with steady-state free precession MRI acquisition for a preclinical 7T scanner providing diffusion-weighted images in less than 500 ms and diffusion tensor imaging assessments in ~1 min with minimal image artifacts in comparison with EPI. Phantom apparent diffusion coefficient (ADC) and fractional anisotropy (FA) assessments obtained from the diffusion-prepared fast imaging with steady-state free precession (DP-FISP) acquisition resulted in good agreement with EPI and spin echo diffusion methods. The mean apparent diffusion coefficient was 2.0 × 10(-3) mm(2) /s, 1.90 × 10(-3) mm(2) /s, and 1.97 × 10(-3) mm(2) /s for DP-FISP, diffusion-weighted spin echo, and diffusion-weighted EPI, respectively. The mean fractional anisotropy was 0.073, 0.072, and 0.070 for diffusion-prepared fast imaging with steady-state free precession, diffusion-weighted spin echo, and diffusion-weighted EPI, respectively. Initial in vivo studies show reasonable ADC values in a normal mouse brain and polycystic rat kidneys.  相似文献   

8.
扩散加权成像对诊断前列腺癌的初步研究   总被引:1,自引:1,他引:0  
目的 探讨基于多次激发回波平面成像(EPI)和二维空间选择激发EPI的快速高分辨扩散加权成像(DWI)对前列腺癌诊断的临床应用价值.资料与方法 对6例健康志愿者和13例经穿刺活检证实的前列腺癌患者进行常规和多序列DWI成像,分别测量各DWI序列扫描图像的信噪比(SNR)和表观扩散系数(ADC)值并进行比较分析.另将5例行前列腺癌根治术的整体前列腺病理标本与DWI显示病灶的部位、范围和数量进行对照分析.结果 与单次激发EPI相比,多次激发EPI提高了图像的空间分辨率和SNR (P<0.05),二维空间选择激发EPI减少了扫描时间分辨率(P<0.05).单次激发、多次激发和二维空间选择激发EPI-DWI序列采集的前列腺癌患者的ADC值与健康志愿者的ADC值差异均有统计学意义(P<0.01).结论 基于多次激发和二维空间选择激发EPI的DWI技术可以提高前列腺图像的空间分辨率和SNR,有助于改善前列腺癌的诊断准确性.  相似文献   

9.
RATIONALE AND OBJECTIVES: Both single-shot diffusion-weighted echo-planar imaging (EPI) and line scan diffusion imaging (LSDI) can be used to obtain magnetic resonance diffusion tensor data and to calculate directionally invariant diffusion anisotropy indices, ie, indirect measures of the organization and coherence of white matter fibers in the brain. To date, there has been no comparison of EPI and LSDI. Because EPI is the most commonly used technique for acquiring diffusion tensor data, it is important to understand the limitations and advantages of LSDI relative to EPI. MATERIALS AND METHODS: Five healthy volunteers underwent EPI and LSDI diffusion on a 1.5 Tesla magnet (General Electric Medical Systems, Milwaukee, WI). Four-mm thick coronal sections, covering the entire brain, were obtained. In addition, one subject was tested with both sequences over four sessions. For each image voxel, eigenvectors and eigenvalues of the diffusion tensor were calculated, and fractional anisotropy (FA) was derived. Several regions of interest were delineated, and for each, mean FA and estimated mean standard deviation were calculated and compared. RESULTS: Results showed no significant differences between EPI and LSDI for mean FA for the five subjects. When intersession reproducibility for one subject was evaluated, there was a significant difference between EPI and LSDI in FA for the corpus callosum and the right uncinate fasciculus. Moreover, errors associated with each FA measure were larger for EPI than for LSDI. CONCLUSION: Results indicate that both EPI- and LSDI-derived FA measures are sufficiently robust. However, when higher accuracy is needed, LSDI provides smaller error and smaller inter-subject and inter-session variability than EPI.  相似文献   

10.
Ignoring diffusion anisotropy can severely hamper the quantitative determination of water and metabolite diffusion in complex tissues. The measurement of the trace of the diffusion tensor provides unambiguous and rotationally invariant ADC values, but usually requires three separate experiments. A single-shot technique developed earlier, originally designed for diffusion trace MR imaging (Mori and van Zijl, Magn Reson Med 1995;33:41-52), was improved and adapted for diffusion trace MR spectroscopy. A double spin-echo pulse sequence was incorporated with four pairs of bipolar gradients with specific predetermined relative signs in each of the three orthogonal directions. The combination of gradient directions leads to cancellation of all off-diagonal tensor elements while constructively adding the diagonal elements. Furthermore, the pulse scheme provides complete compensation for cross-terms between static magnetic field gradients and the applied diffusion gradients, while simultaneously avoiding cross-terms with localization gradients. The sequence was tested at 4.7 T in vivo on rat brain for MRI and on rat skeletal muscle and brain for MRS. It is shown that the average ADC as determined from the measurement of the ADCs in the three orthogonal directions is in close agreement with the ADC obtained along the trace of the diffusion tensor in a single acquisition, for both water and metabolite diffusion. The large differences in water and metabolite diffusion coefficients as measured in the individual orthogonal directions illustrate the need for diffusion trace measurements when accurate and rotationally invariant diffusion quantitation is required. The pulse scheme presented here may be applied for such purposes in MRS and MRI studies.  相似文献   

11.
Diffusion tensor imaging is an important method for noninvasively acquiring structural information of the human brain. For advanced fiber tracking, the acquisition of diffusion‐weighted (DW) images has to be performed along many different spatial directions, resulting in long scan times. Therefore, the ultra‐fast imaging method, echo‐planar imaging (EPI), is mostly used, but this technique suffers from susceptibility‐induced image artefacts and geometric distortions. These problems become even more pronounced at very high magnetic field strengths. In this regard, DW, single‐shot STEAM is an interesting and rapid imaging alternative to EPI‐based methods. DW single‐shot STEAM enables the acquisition of artefact‐free images albeit at the expense of a reduced signal‐to‐noise ratio (SNR), which can be compensated by utilizing high magnetic fields. Here, the application of DW single‐shot STEAM at 4 Tesla is demonstrated. To optimize the SNR and the resolution properties, a new variable flip‐angle computational algorithm is introduced enabling accurate signal evolution computation with a precise calculation of transverse coherences. Omission of radiofrequency (RF) spoiling results in an approximate twofold increase of the DW signal by integration of the stable refocused transverse magnetization. The advantage of the approach is shown in simulations and in vivo experiments. Magn Reson Med 61:372–380, 2009. © 2009 Wiley‐Liss, Inc.  相似文献   

12.
Single breath-hold diffusion-weighted imaging of the abdomen   总被引:22,自引:0,他引:22  
PURPOSE: To generate high quality diffusion-weighted images (DWI) and corresponding isotropic ADC maps of the abdomen with full organ (kidneys) coverage in a single breath-hold. MATERIALS AND METHODS: DWI was performed in 12 healthy subjects with an asymmetric, spin-echo, single-shot EPI readout on a system with high performance gradients (40 mT/minute). The isotropic diffusion coefficient was measured from maps and SNR was determined for both diffusion-weighted and reference images in the liver, spleen, pancreas, and kidneys. In six patients, single-axis diffusion encoding along three orthogonal axes (12 NEX) was employed to assess anisotropic diffusion in kidneys. RESULTS: This technique yielded images of quality and resolution which compares favorably to that of prior work. SNR ranged from 27.0 in liver to 44.1 in kidneys for the diffusion-weighted images, and from 19.6 in liver to 39.0 in kidneys in reference images. ADCs obtained in the renal medulla, renal cortex, liver, spleen, and pancreas were (2091 +/- 55) x 10(-6), (2580 +/- 53) x 10(-6), (1697 +/- 52) x 10(-6), (1047 +/- 82) x 10(-6), and (2605 +/- 168) x 10(-6) mm(2)/second, respectively (mean +/- SE). Apparent diffusion coefficient (ADC) in the renal medulla and cortex were significantly different by paired t-test (P = 4.22 x 10(-10)). Renal medulla and cortex yielded anisotropy indices (AI) of 0.129 and 0.067, respectively. CONCLUSIONS: 1) Single-shot SE EPI DWI in the abdomen with this technique provides high quality images and maps with full organ coverage in a single breath-hold; 2) ADCs obtained in the renal medulla and cortex are significantly different; and 3) diffusion within the renal medulla is moderately anisotropic.  相似文献   

13.
BACKGROUND AND PURPOSE: To prospectively evaluate the signal-to-noise ratio (SNR) improvement in diffusion-weighted imaging (DWI) of the spine with the use of a newly developed non-Carr-Purcell-Meiboom-Gill (non-CPMG) single-shot fast spin-echo (SS-FSE) sequence and its effect on apparent diffusion coefficient (ADC) measurements. MATERIALS AND METHODS: Twenty-four patients were enrolled after written informed consent. DWI of the spine was obtained with an echo-planar imaging (EPI)-based sequence followed by a non-CPMG SS-FSE technique. SNR and ADC values were measured over a lesion-free vertebral corpus. A quality score was assigned for each set of images to assess the image quality. When a spinal lesion was present, contrast-to-noise ratio (CNR) and ADC were also measured. Student t tests were used for statistical analysis. RESULTS: Mean SNR values were 5.83 +/- 2.2 and 11.68 +/- 2.87 for EPI and non-CPMG SS-FSE DWI, respectively. SNR values measured in DWI using parallel imaging were found to be significantly higher (P < .01). Mean ADCs of the spine were 0.53 +/- 0.15 and 0.35 +/- 0.15 x 10(-3) mm(2)/s for EPI and non-CPMG SS-FSE DWI, respectively. Quality scores were found to be higher for the non-CPMG SS-FSE DWI technique (P < .05). Overall lesion CNR was found to be higher in DWI with non-CPMG SS-FSE. CONCLUSION: The non-CPMG SS-FSE technique provides a significant improvement to current EPI-based DWI of the spine. A study including a larger number of patients is required to determine the use of this DWI sequence as a supplementary tool to conventional MR imaging for increasing diagnostic confidence in spinal pathologic conditions.  相似文献   

14.
PURPOSE: To systematically evaluate diffusion anisotropy (DA) using newly defined indices based on the diffusion deviation and mean diffusivity approach. MATERIALS AND METHODS: Measures of amplitude, area, and volume of the DA index (DAI) were measured and compared with regard to their sensitivity to changes in DA, susceptibility to noise in the original diffusion-weighted (DW) images, and contrast-to-noise ratio (CNR) in homogenous regions. Simulations were performed under different levels of noise and DA. Human DTI data were acquired from eight normal volunteers. RESULTS: Indices of area and volume measures provided improved resolution for characterizing the DA compared to the eigenvalue ratio. The amplitude measure showed consistent performances with good CNR and less susceptibility to noise in the original data. CONCLUSION: These indices are rotationally invariant without the requirement of eigenvalue sorting. At low anisotropy, all indices have a similar CNR. For larger DA, the first index (the deviation tensor divided by the DT) shows improved sensitivity, contrast-to-noise ratio (CNR), and noise immunity compared to the other indices.  相似文献   

15.
PURPOSE: To develop a reliable technique for diffusion imaging of the human spinal cord at 1.5 Tesla and to assess potential differences in diffusion anisotropy in cross-sectional images. MATERIALS AND METHODS: A single-shot echo-planar imaging sequence with double spin-echo diffusion preparation was optimized regarding cerebrospinal fluid artifacts, effective resolution, and contrast-to-noise ratios. Eleven healthy volunteers participated in the study for quantitative characterization of diffusion anisotropy in white matter (WM) and gray matter (GM) by means of two diffusion encoding schemes: octahedral-six-directions for fractional anisotropy (FA) evaluation and orthogonal-three-directions for anisotropy index (AI) calculation. RESULTS: Pulse-trigger gated sequences with optimal matrix size (read x phase = 64 x 32) and b-value (700 s/mm(2)) allowed the acquisition of high-resolved images (voxel size = 0.9 x 0.9 x 5.0 mm(3)). The GM butterfly shape was recognizable in both AI and FA maps. Both encoding schemes yielded high diffusion anisotropy in dorsal WM (FA = 0.79 +/- 0.07; AI = 0.39 +/- 0.04). Lateral WM showed slightly lower anisotropy (FA = 0.69 +/- 0.08; AI = 0.35 +/- 0.03) than dorsal WM. Clearly smaller anisotropy was found in regions containing GM (FA = 0.45 +/- 0.06; AI = 0.21 +/- 0.05). CONCLUSION: Diffusion anisotropy data of the spinal cord can be obtained in a clinical setting. Its application seems promising for the assessment of neurological disorders.  相似文献   

16.

Purpose:

To design a time‐efficient patient‐friendly clinical diffusion tensor MRI protocol and postprocessing tool to study the complex muscle architecture of the human forearm.

Materials and Methods:

The 15‐minute examination was done using a 3 T system and consisted of: T1‐weighted imaging, dual echo gradient echo imaging, single‐shot spin‐echo echo‐planar imaging (EPI) diffusion tensor MRI. Postprocessing comprised of signal‐to‐noise improvement by a Rician noise suppression algorithm, image registration to correct for motion and eddy currents, and correction of susceptibility‐induced deformations using magnetic field inhomogeneity maps. Per muscle one to five regions of interest were used for fiber tractography seeding. To validate our approach, the reconstructions of individual muscles from the in vivo scans were compared to photographs of those dissected from a human cadaver forearm.

Results:

Postprocessing proved essential to allow muscle segmentation based on combined T1‐weighted and diffusion tensor data. The protocol can be applied more generally to study human muscle architecture in other parts of the body.

Conclusion:

The proposed protocol was able to visualize the muscle architecture of the human forearm in great detail and showed excellent agreement with the dissected cadaver muscles. J. Magn. Reson. Imaging 2012;36:237–248. © 2012 Wiley Periodicals, Inc.  相似文献   

17.
PURPOSE: To obtain normative human cerebral data and evaluate the anatomic information in quantitative diffusion anisotropy magnetic resonance (MR) imaging. MATERIALS AND METHODS: Quantitative diffusion anisotropy MR images were obtained in 13 healthy adults by using single-shot echo-planar MR imaging and a combination of tetrahedral and orthogonal gradient encoding (whole-brain coverage in about 1 minute). White matter (WM) anatomy was assessed at visual inspection, and values were measured in various brain regions. Different anisotropy measures, including total anisotropy (A sigma), were compared on the basis of information content, rotational invariance, and susceptibility to noise. Partial volume and noise effects were simulated. RESULTS: Anisotropy MR images depicted WM features not typically seen on conventional MR images (e.g., external capsule, thalamic substructures, basal ganglia, occipital WM, thickness of the internal capsule). Statistically significant anisotropy differences occurred across brain regions, which were reproducible within and across subjects. A sigma was highest in commissural WM and progressively lower in projection and association WM. This order paralleled that of known resistance to spread of vasogenic edema, which suggested that anisotropy may be sensitive to WM histologic structure. Gray matter (GM) A sigma data were consistent with zero anisotropy, and partial volume WM-GM effects were approximately linear. A sigma image quality could be effectively improved by means of averaging. CONCLUSION: Quantitative diffusion anisotropy images can be obtained rapidly and demonstrate subtle WM anatomy. Different histologic types of WM have significant and reproducible anisotropy differences.  相似文献   

18.
The in vivo apparent diffusion tensor (ADT) of spinal cord was measured in nine rats at 2.0 T using an interleaved multi-shot echo planar imaging (EPI) diffusion sequence. A technique that combines sliding acquisition and phase correction, based on a calibration scan, to reduce ghosting artifacts in the images introduced by the strong diffusion-sensitizing gradients was described. Two rotationally invariant parameters, the trace (actually trace/3, to be consistent with the published values) and the lattice anisotropy index (LAI) were estimated from the ADT. In in vivo cords, the mean white matter (WM) trace value (1.05 +/- 0.13 x 10(-3) mm(2)/sec) was found to be significantly higher than the gray matter (GM) trace (0. 84 +/- 0.12 x 10(-3) mm(2)/sec, p < 0.0025). Significant anisotropic diffusion was observed in both WM and GM, with greater anisotropy in the WM (LAI=0.59 +/- 0.04) than in the GM (LAI=0.47 +/- 0.06, p < 0. 0001). These results are in agreement with the in vivo values determined using the conventional spin-echo sequence. Magn Reson Med 42:300-306, 1999.  相似文献   

19.
Single-shot echo-planar imaging has been used widely in diffusion magnetic resonance imaging due to the difficulties in correcting motion-induced phase corruption in multishot data. Readout-segmented EPI has addressed the multishot problem by introducing a two-dimensional nonlinear navigator correction with online reacquisition of uncorrectable data to enable acquisition of high-resolution diffusion data with reduced susceptibility artifact and T*(2) blurring. The primary shortcoming of readout-segmented EPI in its current form is its long acquisition time (longer than similar resolution single-shot echo-planar imaging protocols by approximately the number of readout segments), which limits the number of diffusion directions. By omitting readout segments at one side of k-space and using partial Fourier reconstruction, readout-segmented EPI imaging times could be reduced. In this study, the effects of homodyne and projection onto convex sets reconstructions on estimates of the fractional anisotropy, mean diffusivity, and diffusion orientation in fiber tracts and raw T(2)- and trace-weighted signal are compared, along with signal-to-noise ratio results. It is found that projections onto convex sets reconstruction with 3/5 segments in a 2 mm isotropic diffusion tensor image acquisition and 9/13 segments in a 0.9 × 0.9 × 4.0 mm(3) diffusion-weighted image acquisition provide good fidelity relative to the full k-space parameters. This allows application of readout-segmented EPI to tractography studies, and clinical stroke and oncology protocols.  相似文献   

20.
The purpose of this study was to apply multishot echoplanar imaging (EPI) to the female pelvis and to compare the results with respiratory triggered fast spin echo with fat-suppression (fFSE). Twenty-seven patients with pelvic disease were examined. EPI images were obtained using 8 shots with breath-holding (bhEPI) and 16 shots without breath-holding (bEPI), while the FSE sequence was fat-suppressed respiratory-triggered FSE. Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and contrast to uterus or ovary (Contrast) were compared between EPI and FSE images. Identification of uterus, ovary, and tumors was carried out simultaneously. In SNR, CNR, and Contrast, EPI could not provide image quality superior to that of fFSE. Moreover, on EPI images, identification of uterus, ovary, and tumors was judged to be inferior or equal. In conclusion, multishot EPI cannot replace fFSE sequences in imaging of the female pelvis. However, because EPI has heavily T2-weighted contrast, the EPI sequence can be a valuable adjunct to routine examination.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号