共查询到20条相似文献,搜索用时 0 毫秒
1.
Yumei Wang Yan Liu Yaping Ding Nan Sun Yafang Gong Shangxian Gao 《Archives of virology》2014,159(12):3365-3370
Human papillomavirus (HPV) is associated with cervical cancer. In this study, we developed a high-throughput microwell-plate hybrid capture (MPHC) method for epidemiological studies of high-risk HPV (HRHPV). The results with 1238 cervical specimens from female outpatients showed a concordance rate of 94.3 % between the MPHC and Hybrid Capture II assay. The MPHC assay showed an average HRHPV rate of 29.3 % for high-risk populations in populous cities of China. The established MPHC assay could sensitively and specifically detect 13 types of HRHPV and is suitable for large-scale screening, especially in areas where real-time PCR or fluorescence equipment is unavailable. 相似文献
2.
Comparison of the Digene HC2 assay and the Roche AMPLICOR human papillomavirus (HPV) test for detection of high-risk HPV genotypes in cervical samples 下载免费PDF全文
Sandri MT Lentati P Benini E Dell'Orto P Zorzino L Carozzi FM Maisonneuve P Passerini R Salvatici M Casadio C Boveri S Sideri M 《Journal of clinical microbiology》2006,44(6):2141-2146
Many different methods with different sensitivity and specificity have been proposed to detect the presence of high-risk human papillomavirus (HR HPV) in cervical samples. The HC2 is one of the most widely used. Recently, a new standardized PCR-based method, the AMPLICOR HPV test, has been introduced. Both assays recognize the same 13 HR HPV genotypes. The performances of these two commercially available assays were compared in 167 consecutive women (for a total of 168 samples) who presented at the Colposcopy Clinic either for a follow-up or for a diagnostic visit. Concordant results were found in 140/168 cervical samples (overall agreement, 83%; Cohen's kappa = 0.63). Twenty-eight samples gave discordant results: 20 were positive with the AMPLICOR HPV test and negative with the HC2 assay, and 8 were negative with the AMPLICOR HPV test and positive with the HC2 assay. The genotyping showed that no HR HPV was detected in the 8 HC2 assay-positive AMPLICOR HPV test-negative samples, while in 8/20 AMPLICOR HPV test-positive HC2 assay-negative samples, an HR HPV genotype was found. The AMPLICOR HPV test scored positive in a significantly higher percentage of subjects with normal Pap smears. All 7 cervical intraepithelial neoplasia grade 3 patients scored positive with the AMPLICOR HPV test, while 2 of them scored negative with HC2. Both tests had positive results in the only patient with squamous cell carcinoma. In conclusion, this study shows that the HC2 assay and the AMPLICOR HPV test give comparable results, with both being suitable for routine use. The differences noted in some cases may suggest a different optimal clinical use. 相似文献
3.
Comparison of the Digene Hybrid Capture 2 assay and Roche AMPLICOR and LINEAR ARRAY human papillomavirus (HPV) tests in detecting high-risk HPV genotypes in specimens from women with previous abnormal Pap smear results 总被引:2,自引:1,他引:1 下载免费PDF全文
Stevens MP Garland SM Rudland E Tan J Quinn MA Tabrizi SN 《Journal of clinical microbiology》2007,45(7):2130-2137
The development of cervical cancer is strongly associated with the presence of persistent high-risk (HR) human papillomavirus (HPV) infection. Recently, the commercially manufactured PCR-based Roche AMPLICOR (AMP) and LINEAR ARRAY (LA) HPV tests have become available for HPV detection. However, knowledge of their clinical performance compared to the U.S. Food and Drug Administration-approved Hybrid Capture 2 (HC2) assay is limited. This study evaluated the concordance between the HC2, AMP, and LA tests in detecting HR-HPV among a cohort of 1,679 women with previous abnormal Pap smear results. Overall, 1,393 specimens (81.3%) generated concordant results for HR-HPV presence or absence by the three assays. The concordance levels were substantial between the HC2 and AMP tests (84.4%, kappa = 0.6419) and between the HC2 and LA tests (84.0%, kappa = 0.6341) and nearly perfect between the AMP and LA tests (97.8%, kappa = 0.9441). HR-HPV prevalence, as detected by the AMP or LA tests, was significantly higher among women with cytological or histological high-grade disease (CIN2 or greater) than that detected by HC2 (P < 0.0001). The AMP and LA tests exhibited greater sensitivity, but lower specificity, than HC2 for detecting HR-HPV among this cohort of women with underlying cervical abnormalities, particularly among subjects with histologically proven high-grade disease. Both PCR-based HPV tests may be valuable in the management of care for women with underlying cervical abnormalities, in predicting treatment success, and in studying the clearance or acquisition of new infections. 相似文献
4.
This study compared the clinical performance of the Digene Hybrid Capture 2 (HC2) assay to that of a prototype Third Wave Invader human papillomavirus (HPV) (IHPV) analyte-specific reagent-based assay for the detection of oncogenic or "high-risk" (HR) HPV DNA using liquid-based cytology specimens. In total, 821 ThinPrep vials were tested using both assays. In accordance with the type-specific probes contained within each test, the sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) for the IHPV assay were 95.9%, 97.6%, 97.5%, and 96.1%, respectively, and those for the HC2 assay were 98.1%, 86.2%, 87.1%, and 97.9%. Overall, the sensitivity and NPV were comparable between the assays, but the IHPV assay demonstrated a better specificity and PPV, since the IHPV assay had fewer false-positive HR HPV results. The incorporation of an internal control to evaluate the cellularity of the test material is an important feature of the IHPV assay and should reduce the risk of false-negative results due to insufficient sample collection rather than the lack of HR HPV DNA. An additional benefit of the IHPV assay was the smaller sample volume required (1 ml versus 4 ml for the HC2 assay). 相似文献
5.
Persistent infection by high‐risk human papillomavirus (HR‐HPV) is a cause of cervical cancer. The use of HPV detection in cervical screening programs may improve the ability to identify women at risk of cervical cancer. Therefore, the development of appropriate methods for the detection of HR‐HPV is essential. The aim of this study was to evaluate the clinical performance of the CLART Human Papillomavirus 2 assay (CLART) in comparison with the Hybrid Capture 2 test (HC2), using a clinical cut‐off of cervical intraepithelial neoplasia grade 2 or worse. Discrepant results were analyzed further by the PapilloCheck HPV genotyping system. In the 425 studied women, HR‐HPV positivity rates were similar by both tests (CLART‐13 HR‐HPV: 63.1%; CLART‐17 HR‐HPV: 64.7%; HC2: 64.5%). Agreement between CLART‐13 HR‐HPV (κ = 0.969; concordance level 98.6%), CLART‐17 HR‐HPV (κ = 0.974; concordance level 98.8%), and HC2 were very good. When 13 HR‐HPV types were considered, the two tests showed a clinical sensitivity of 96% (95% CI: 92.6–97.9). The clinical specificity of CLART‐13 HR‐HPV was 73.6% (95% CI: 66.7–79.5) for cervical intraepithelial neoplasia grade 2 or worse, which was comparable to HC2 (71.4%; 95% CI: 64.3–77.5). When all 17 HR‐HPV types were considered, CLART showed a clinical sensitivity of 96.9% (95% CI: 93.8–98.5) and a clinical specificity of 71.9% (95% CI: 64.9–78.0). In conclusion, the CLART assay is efficient, sensitive, reproducible, and has a similar performance to HC2 for cervical intraepithelial neoplasia grade 2 or worse. Furthermore, this assay has the advantage of detecting and genotyping 35 HPV types by a single test, which can provide additional information on the predictive value of infection with HR‐HPV. J. Med. Virol. 83:272–276, 2011. © 2010 Wiley‐Liss, Inc. 相似文献
6.
Schiffman M Wheeler CM Dasgupta A Solomon D Castle PE;ALTS Group 《American journal of clinical pathology》2005,124(5):722-732
We evaluated Hybrid Capture 2 (HC2) and polymerase chain reaction (PCR) results for paired specimens collected at 19,187 visits from 5,026 of 5,060 women participating in the Atypical Squamous Cells of Undetermined Significance/Low-Grade Squamous Intraepithelial Lesion Triage Study (ALTS). We examined the test agreement between HC2 and PCR detection for any of 13 carcinogenic human papillomavirus types targeted by HC2 and compared clinical performance of the 2 tests for detecting concurrent and follow-up cervical intraepithelial neoplasia (CIN) 3 or cancer. The k value for the 2 assays was 0.65 (95% confidence interval, 0.64-0.66), with 82.7% crude agreement. HC2 was more sensitive (93.6% vs 89.3%; P < .0005) but less specific (41.2% vs 48.5%; P < .0005) than PCR for detecting 2-year cumulative CIN 3 or cancer (n = 503). The presence of multiple types as detected by PCR and/or cytologic abnormality increased the likelihood of an HC2+ result. Increased sensitivity of HC2 compared with PCR was surprising, given the theoretical advantages of PCR-based methods for analytic sensitivity. Smaller amounts of material used in PCR could have limited its sensitivity, but our results demonstrate the importance of optimization and standardization of PCR-based assays for clinical applications. 相似文献
7.
Clinical cervical cytology specimens (n = 466) collected in PreservCyt (Hologic Inc.) were used to evaluate the agreement between Hybrid Capture 2 (hc2; Qiagen) and cobas 4800 (c4800; Roche Molecular Diagnostics) for the detection of high-risk human papillomavirus (HR HPV) genotype infections. The agreement between the two assays was 93.8% (kappa = 0.87; 95% confidence interval, 0.828 to 0.918), with 186 and 251 concordant positive and negative results, respectively. All 186 concordant positives were confirmed using the Linear Array (LA; Roche Molecular Diagnostics) genotyping test. Of the 29 samples with discordant results (6.2%), 18 were hc2 positive and LA verified 17 as positive for HR HPV. Eleven discordant specimens were c4800 positive, and LA confirmed 5 as positive for HR HPV. As of October 2009, practice guidelines in Alberta, Canada, recommend reflex HPV testing for women over 30 years old with atypical squamous cells of undetermined significance (ASCUS) and for women over 50 years old with low-grade squamous intraepithelial lesions (LSIL) to help prioritize those who should undergo further evaluation. In this study, agreement between hc2 and c4800 results for samples from women over 30 years old with ASCUS cytology was 92.3% (n = 13), while no samples from women over 50 years old with LSIL cytology were identified for analysis. 相似文献
8.
Comparison of the hybrid capture tube test and PCR for detection of human papillomavirus DNA in cervical specimens. 总被引:5,自引:3,他引:5 下载免费PDF全文
J U Cope A Hildesheim M H Schiffman M M Manos A T Lrincz R D Burk A G Glass C Greer J Buckland K Helgesen D R Scott M E Sherman R J Kurman K L Liaw 《Journal of clinical microbiology》1997,35(9):2262-2265
The strong association of human papillomavirus (HPV) and cervical cancer makes it important to study HPV detection methods that may play a role in cervical cancer screening. We compared two DNA methods that are commonly used for HPV research in the United States: the MY09/MY11 L1 consensus primer PCR-based test and the first-generation Hybrid Capture tube method (HCT). Laboratory assays by each method were performed with 596 cervicovaginal specimens collected from participants in a large cohort study conducted in Portland, Oreg. Included were 499 specimens from women whose cytology was normal and 97 specimens from women with squamous intraepithelial lesions (SILs). The overall HPV DNA positivity for known types was 22.5% by PCR compared to 13.6% by HCT. When the analysis was restricted to the 14 HPV types detectable by both methods, the sensitivity of HCT, with PCR used as the standard for HPV status, was higher for specimens from women with concurrent SILs (81.0%) than for specimens from women with normal cytology (46.7%). Among specimens testing positive by both methods, 97.2% of the time the two methods agreed on whether specimens were positive for cancer-associated HPV types. Both of these HPV test methods provide information that supplements the information provided by the Pap smear. The PCR method has higher analytic sensitivity than HCT in detecting HPV, but HCT may be helpful in identifying women with concurrent SILs. 相似文献
9.
Results of human papillomavirus DNA testing with the hybrid capture 2 assay are reproducible 总被引:6,自引:0,他引:6 下载免费PDF全文
Castle PE Lorincz AT Mielzynska-Lohnas I Scott DR Glass AG Sherman ME Schussler JE Schiffman M 《Journal of clinical microbiology》2002,40(3):1088-1090
Reproducibility of the Hybrid Capture 2 Test (HC 2) for human papillomavirus (HPV) DNA detection was evaluated by assaying frozen cervical specimens in 1997 and again in 2001 from 1,775 women with normal cervical cytology. Using a cutoff point of 1.0 pg of HPV DNA/ml between a negative and a positive test result, the result of the kappa test for agreement was 0.72 (a kappa value of >0.60 is considered good agreement). Using cutoff points of 1.0 and 10.0 pg/ml between negative and low positive and between low positive and high positive, respectively, the kappa was 0.68 and the linear-weighted kappa was 0.76. The results of this study indicate that HC 2 testing is reproducible even among cytologically normal women with low test values. 相似文献
10.
Hybrid capture II, a new sensitive test for human papillomavirus detection. Comparison with hybrid capture I and PCR results in cervical lesions 下载免费PDF全文
Clavel C Masure M Putaud I Thomas K Bory JP Gabriel R Quereux C Birembaut P 《Journal of clinical pathology》1998,51(10):737-740
AIM: To test a new assay for the detection of human papillomavirus (HPV) DNA, hybrid capture II (HC II), compared with the previous commercialized hybrid capture I (HC I) and polymerase chain reaction (PCR) results on cervical scrapes from fresh cone excision biopsy samples. METHODS: The three methods were used on cervical scrapes from 42 fresh cone excision biopsy samples. There were nine metaplastic and inflammatory lesions, five low grade lesions, and 28 high grade lesions. PCR was performed using the general primers GP5+/GP6+. The viral load of high risk HPV DNA was estimated by the ratio of relative light units to positive control values in the samples. RESULTS: The sensitivity of HC I for the detection of high grade lesions was 71.4%, while it was 92.8% for HC II and 96.4% for the PCR. Considering only the absence of detectable cervical in situ neoplasia, the specificity was 88.9% for HC I, 66.7% for HC II, and 66.7% for PCR. With HC II, for a ratio of cervical sample to normal control of > 200, the sensitivity for the detection of high grade lesion was only 34.6% with a specificity of 66.7%. CONCLUSIONS: HPV detection with the HC II assay is more sensitive than the previous HC I and represents a more convenient and easier test than PCR for routine use. Nevertheless the viral load estimated with this test cannot be a reliable predictive indicator of high grade lesions. 相似文献
11.
Comparison between prototype hybrid capture 3 and hybrid capture 2 human papillomavirus DNA assays for detection of high-grade cervical intraepithelial neoplasia and cancer 总被引:3,自引:0,他引:3 下载免费PDF全文
Castle PE Lorincz AT Scott DR Sherman ME Glass AG Rush BB Wacholder S Burk RD Manos MM Schussler JE Macomber P Schiffman M 《Journal of clinical microbiology》2003,41(9):4022-4030
We compared the performance of a prototype version of the Hybrid Capture 3 (HC3) human papillomavirus (HPV) DNA assay to the current generation Hybrid Capture 2 (HC2) assay, both of which target 13 oncogenic HPV types, for the detection of cervical intraepithelial neoplasia grade 3 and cancer (CIN3+) with cervicovaginal lavage specimens collected at enrollment into a 10-year cohort study at Kaiser Permanente (Portland, Oreg.). HC3 results for a risk-stratified sample (n = 4,364) were compared to HC2 results for the entire cohort (n = 20,810) with receiver operating characteristics curves, and the optimal cut points for both tests (relative light units [RLU]/positive control [PC]) for the detection of CIN3+ were determined. Specimens were also tested for HPV16 and HPV18 with separate HC3 type-specific probes. The optimal cut point for detecting CIN3+ was 1.0 RLU/PC for HC2, as previously shown, and was 0.6 RLU/PC for HC3. At the optimal cut points, HC3 and HC2 had similar screening performance characteristics for CIN3+ diagnosed at the enrollment visit. In analyses that included cases CIN3+ at enrollment and those diagnosed during early follow-up, HC3 had nonsignificantly higher sensitivity and equal specificity for the detection of CIN3+ compared to HC2; this increase in sensitivity was primarily the result of increased detection of CIN3+ in women who were 30 years of age or older and were cytologically negative (P = 0.006). We also compared the performance of the hybrid capture tests to MY09/11 L1 consensus primer PCR results (n = 1,247). HC3 was less likely than HC2 to test positive for specimens that tested positive by PCR for any untargeted types (P < 0.001). HC3 was less likely than HC2 to test positive for untargeted PCR-detected single infections with HPV53 (P = 0.001) and HPV66 (P = 0.01). There was good agreement between test positivity by PCR and by single type-specific HC3 probes for HPV16 (kappa = 0.76; 95% confidence interval [CI] = 0.71 to 0.82) and for HPV18 (kappa = 0.73; 95% CI = 0.68 to 0.79). In conclusion, we suggest that HC3 (>/=0.6 RLU/PC) may be slightly more sensitive than and equally specific test as HC2 (>/=1.0 RLU/PC) for the detection of CIN3+ over the duration of typical screening intervals. 相似文献
12.
Fatima Galan‐Sanchez Manuel A. Rodriguez‐Iglesias 《APMIS : acta pathologica, microbiologica, et immunologica Scandinavica》2010,118(9):681-684
Galan‐Sanchez F, Rodriguez‐Iglesias MA. Use of Cervista HPV HR assay for detection of human papillomavirus in samples with hybrid capture borderline negative results. APMIS 2010; 118: 681–4. We have evaluated Cervista HPV HR for papillomavirus detection in 65 samples previously borderline negative by the hybrid capture method (Digene), using InnoLipa and sequencing as confirmatory techniques. Nine samples were found to be positive by Cervista HPV HR, of which five (7.6%) were confirmed by InnoLipa. Four samples (6.1%) were false positive, of which three samples were reactive for A9 probes. The Cervista HPV HR assay can detect HPV‐positive samples from those with hybrid capture borderline results but can produce false‐positive results when tested for reactivity with A9 probes. 相似文献
13.
Agreement between the AMPLICOR Human Papillomavirus Test and the Hybrid Capture 2 assay in detection of high-risk human papillomavirus and diagnosis of biopsy-confirmed high-grade cervical disease 总被引:2,自引:0,他引:2 下载免费PDF全文
Carozzi F Bisanzi S Sani C Zappa M Cecchini S Ciatto S Confortini M 《Journal of clinical microbiology》2007,45(2):364-369
The AMPLICOR HPV test (AMP) and the Hybrid Capture 2 assay (HC2) detect 13 high-risk human papillomavirus (HR-HPV) types. Evaluation of comparative performance with clinical samples is needed to allow informed implementation of AMP into clinical practice. AMP was used (i) to assess the prevalence of HR-HPV in 1,032 samples of known cytology, HC2 status, and/or confirmed histology; (ii) to determine agreement between AMP and HC2; (iii) to evaluate the clinical sensitivity and specificity for detecting HR-HPV; and (iv) to detect the presence of biopsy-confirmed high-grade cervical intraepithelial neoplasia. The prevalence of HR-HPV was 39.3% and 45.6% by AMP and HC2, respectively. Overall agreement was 89.2% (kappa value, 0.78). Of 509 HR-HPV-negative specimens by HC2, 488 (95.9%) were AMP negative. Of 427 HR-HPV-positive specimens by HC2, 347 (81.2%) were AMP positive. In comparing the ability to detect high-grade squamous intraepithelial lesions (HSIL), the two tests were positive for all HSIL samples. Both tests performed similarly on CIN2+ samples (clinical sensitivities were 96.7% and 97.8%, respectively, for AMP and HC2). The clinical specificities of AMP and HC2 were comparable (54.9% versus 51.6%; P=0.18). Genotyping of 20 HC2-negative/AMP-positive cases using alternative technologies revealed target HR genotypes in 63.1% of cases and low-risk types in 15.7% of cases, while 21% of cases were negative. In conclusion, AMP provides a viable alternative to HC2, with good agreement for samples with high-grade cytology and similar sensitivity in detecting CIN2+ lesions. 相似文献
14.
15.
Comparison of PCR and hybrid capture methods for detection of human papillomavirus in injection drug-using women at high risk of human immunodeficiency virus infection. 总被引:3,自引:2,他引:1 下载免费PDF全文
We compared Hybrid Capture, a new technique for detection of human papillomaviruses (HPV), with a PCR assay based on L1 consensus primers. By both methods, the HPV prevalence was higher in human immunodeficiency virus (HIV)-positive women than in HIV-negative women. PCR had a higher sensitivity (0.89 versus 0.48) but lower specificity (0.43 versus 0.93) for detection of Pap smear abnormalities, compared to Hybrid Capture. The higher intensity of hybridization signal by PCR was related to higher estimates of viral load by Hybrid Capture. 相似文献
16.
Human papillomavirus testing with the hybrid capture 2 assay and PCR as screening tools 总被引:6,自引:0,他引:6 下载免费PDF全文
Kulmala SM Syrjänen S Shabalova I Petrovichev N Kozachenko V Podistov J Ivanchenko O Zakharenko S Nerovjna R Kljukina L Branovskaja M Grunberga V Juschenko A Tosi P Santopietro R Syrjänen K 《Journal of clinical microbiology》2004,42(6):2470-2475
The recognition of high-risk human papillomaviruses (HPVs) as etiological agents of cervical cancer has increased the demands to use testing for HPV for the detection of abnormal cervical smears and for cervical cancer screening. The present study compared the performance of the Hybrid Capture 2 (HC2) assay with that of PCR for the detection of significant cervical lesions in 1,511 women with different risks for HPV infections in three New Independent States of the former Soviet Union. The results showed that the level of agreement between the HC2 assay and PCR was substantial, with a kappa (Cohen) value of 0.669 (95% confidence interval [CI], 0.629 to 0.709). Of the 228 samples with discrepant results, 92 were positive by the HC2 assay but negative by PCR, whereas 136 samples were PCR positive but HC2 assay negative. The positive predictive values (PPVs) of the HC2 assay and PCR in detecting high-grade intraepithelial lesions (HSILs) were 4.5% (95% CI, 3.5 to 5.5%) and 3.6% (95% CI, 2.7 to 4.5%), respectively, and the negative predictive values (NPVs) were 99.6% (95% CI, 99.3 to 99.9%) and 99.3% (95% CI, 98.9 to 99.7%), respectively. The sensitivities of the HC2 assay and PCR for the detection of HSILs were 85.2 and 74.0%, respectively, and the specificities were 67.2 and 64.1%, respectively. In receiver operating characteristic (ROC) analysis, the performance of the HC2 assay for the detection of HSILs was excellent (P = 0.0001); the area under the ROC analysis curve was 0.858 (95% CI, 0.811 to 0.905), and the optimal balance between sensitivity (86.5%) and specificity (80%) was obtained with an HC2 assay cutoff level of 15.6 relative light units/positive control. Use of this cutoff would increase the specificity of the HC2 assay to 80.0% without compromising sensitivity. In conclusion, the results of PCR and the HC2 assay were concordant for 85% of samples, resulting in substantial reproducibility. Both tests had low PPVs, equal specificities, and equal (almost 100%) NPVs for the detection of HSILs; but the sensitivity of the HC2 assay was slightly better. 相似文献
17.
Tabrizi SN Stevens MP Khan ZA Chow C Devitt MA Garland SM 《Journal of clinical microbiology》2012,50(8):2796-2798
PapType human papillomavirus (HPV) assay was compared to Hybrid Capture 2 (HC2), Amplicor (Amp), and Linear Array (LA) HPV tests in 894 women undergoing management for a high-grade Pap smear abnormality. The sensitivity in detection of underlying high-grade histological diagnosis by PapType was 90.3% and by HC2 was 79.8%, while by Amp and LA it was 92.4% and 91.6%, respectively. The specificities were 52.5%, 55.3%, 49.4%, and 51.7% for PapType, HC2, Amp, and LA, respectively. 相似文献
18.
Detection of high-risk HPV types by the hybrid capture 2 test 总被引:9,自引:0,他引:9
Terry G Ho L Londesborough P Cuzick J Mielzynska-Lohnas I Lorincz A 《Journal of medical virology》2001,65(1):155-162
A hybrid capture test that can be used to detect at least 13 high-risk HPV types (referred to collectively as HPV-HR) in cervical scrapes (Hybrid Capture 2 probe set B, HC2-B) was evaluated. The HC2-B test is accurate and highly reproducible and the results obtained show excellent agreement with those obtained by a multiplexed type-specific polymerase chain reaction (mts-PCR). An additional assay to identify a subset of HPV-HR types may improve specificity without compromising sensitivity in HC2-B positive specimens with a test result close to the cut-off value given by 1 pg/ml HPV DNA. 相似文献
19.
A Daponte S Pournaras I Mademtzis C Hadjichristodoulou E Kostopoulou A N Maniatis I E Messinis 《Journal of clinical virology》2006,36(3):189-193
BACKGROUND: During the last decade, increasing efforts have focused on HPV detection in self-obtained samples, to increase the overall proportion of patients participating in cervical cancer screening procedures. OBJECTIVES: A clinical evaluation study of an optimized protocol for PCR detection of high-risk human papillomavirus (HPV) types in urine compared with cervical samples in consecutive women referred to the colposcopy clinic with abnormal cervical cytology. STUDY DESIGN: Paired urine and cervical specimens were collected from 100 consecutive women referred to the colposcopy clinic with abnormal cervical cytology and normal urine parameters. In-house and a commercial PCR method for the detection of HPV types 16 and 18, and a commercial multiplex PCR for HPV types 6, 11, 16, 18, and 33 were performed. All HPV cervix-positive/urine-negative paired urine samples were spiked with serial dilutions of cell lines infected with HPV 16 or 18 to test the sensitivity of HPV detection in these urine samples. RESULTS: In all but two cases HPV type 16 was detected. In cancer cases, the urine/cervix HPV detection sensitivity was 88.8%; in cases with high-grade lesions it was 76.5%; and in cases with low-grade lesions it was 45.5%. In all concordant cases the same HPV type was detected in both samples. The urine/cervix HPV detection sensitivity was higher when urine samples contained two or more epithelial cells per field in urine microscopy. HPV detection in 9 cervix-positive but urine-negative urine samples spiked with serial dilutions of HPV-positive cell lines showed that in these cases urine PCR inhibitors did not affect PCR amplification. CONCLUSIONS: A higher urine/cervix HPV detection sensitivity in cancer and high-grade lesions suggests that urine testing could be used to detect HPV mainly when these lesions are present. 相似文献
20.
C Clavel M Masure M Levert I Putaud C Mangeonjean M Lorenzato P Nazeyrollas R Gabriel C Quereux P Birembaut 《Diagnostic molecular pathology》2000,9(3):145-150
The reliability of the Hybrid Capture II (HC-II; Digene, Silver Spring, MD, U.S.A.) assay was tested in detecting 18 human Papillomavirus (HPV) types for the screening of cervical lesions. Cytology, HPV testing, colposcopy, and biopsy were used to monitor 204 women with normal smears at the first entry. The median follow-up was 15 months (range, 4-27 months). The primary endpoint was clinical progression defined as the presence of a cervical intraepithelial lesion at the biopsy. In the patient population of 204 HPV-infected women, 81 (39.7%) had a persistent HPV infection at two or three examinations with a final histologic diagnosis of 14 high-grade and 13 low-grade squamous intraepithelial lesions (SIL) within 4 to 22 months. Women with regressive HPV infection did not develop any lesion during the same period. The evaluation of the viral load of high-risk HPV by the HC-II did not represent a sensitive approach to predict the persistence or the apparition of high-grade lesions. Thus, persistent high-risk HPV infection detected with HC-II represents a reliable tool to select populations at risk for the development of high-grade cervical lesions. 相似文献