首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 38 毫秒
1.
PurposeThe purpose of this retrospective study was to investigate factors that affected the continuing use of RPDs and the patients’ satisfaction 5 years after delivery.MethodsSixty-seven patients treated with 90 RPDs delivered at the Tohoku University Hospital (Sendai, Japan) between 1996 and 2001 participated in this study. The patients were re-examined 5 years after delivery. Data were collected from clinical records and a questionnaire was used to evaluate the patients’ delivery use of the RPDs. The RPD treatment was divided into three categories labeled as ‘successful’, ‘remake’, and ‘failure’. Twelve factors that might affect the continuing use and 15 factors regarding satisfaction were evaluated. Stepwise logistic regression analysis was used to assess statistical significance.ResultsFifty-five RPDs were regarded as successful, 21 were remake, and 14 failure. Statistically significant associations were found between the continuing use and the patient's age (P = 0.002), location of the edentulous area (P = 0.047), number of occluding pairs of teeth (P = 0.038), number of occlusal rests (P = 0.038), pain while using RPDs (P = 0.006), color of the artificial teeth (P = 0.021), and tooth shape and set-up (P = 0.022).ConclusionsThese findings suggest that the continuing use of RPDs is related to factors such as the patient's age, location of edentulous area, number of occluding pairs of teeth, and number of occlusal rests, satisfaction including pain while using RPDs, color of the artificial teeth, and tooth shape and set-up.  相似文献   

2.
PurposeThe purpose of this study was to determine the influence of mandibular free-end partial edentulism and the wearing of removable partial dentures in the partially edentulous area on the force exerted on maxillary anterior teeth.MethodsA commercially available jaw model with exchangeable teeth was used. Seven experimental conditions of mandibular free-end edentulism were set up and a distal extension removable partial denture to replace missing posterior teeth was fabricated. Strain gauges were attached to the root surface of the maxillary left central incisor, canine, first premolar and first molar, and the force exerted on them was calculated based on the calibration coefficient. An occlusal load of 49 N was applied and the forces were compared with the Kruskal–Wallis test (P < 0.05).ResultsThe force exerted on the maxillary anterior teeth increased significantly as the number of remaining teeth decreased. The force exerted on the maxillary anterior teeth decreased significantly with use of a removable partial denture.ConclusionsWhen the number of remaining teeth decreases in mandibular free-end partial edentulism, the burden on the maxillary anterior teeth increases. Our findings suggest that for patients with mandibular free-end partial edentulism, wearing a removable partial denture is effective in preserving the remaining teeth by reducing excessive stress.  相似文献   

3.
PurposeThe present study aimed to evaluate the retention and stress distribution of conventional (C) RPD and compare to RPD associated to implant for support (IS) and retention (IR).MethodsFrameworks were cast from cp Ti (n = 18) and Co–Cr alloy (n = 18) by plasma and injected by vacuum–pressure. Conventional RPDs were compared to implant associated RPDs using a distal implant to support (IS) or to support and retain (IR) RPD. The specimens were subjected to insertion/removal cycles simulating 5 years of use and the retention force (N) was measured or evaluated. A mixed linear model was used to analyze the data (α = 0.05). Photoelastic models were qualitatively examined for stress when an occlusal load of 15 kgf was applied over support teeth and RPD.ResultsRetention force of IR RPDs is greater than IS and C RPDs for both cp Ti and Co–Cr alloy specimens. Retention force of cp Ti RPDs increased initially and was maintained throughout 5 years of simulation test while Co–Cr RPDs presented a decrease at the beginning of the test and had their retention force maintained throughout the test. Implant placement at residual alveolar ridge decreased stress around teeth, mainly in the first premolar. Stress concentration in the IS RPD is slightly greater than in the IR RPD.ConclusionThe results suggest that implant placement at the distal extension improves retention and stress distribution of RPDs.  相似文献   

4.
ObjectiveThe aim of this study was assessing the changes in both clinical and microbiological parameters of healthy individuals after rehabilitation with removable partial denture (RPD).Design11 women received unilateral or bilateral free-end saddle RPD in the mandibular arch. Clinical and microbiological parameters of abutment, non-abutment, and antagonist teeth were assessed at baseline (RPD installation) and after 7, 30, 90, and 180 days of function. The Checkerboard DNA–DNA hybridization technique was used to identify and quantify up to 43 different microbial species from subgingival biofilm samples. Probing depth, gingival recession, and bleeding on probing were also investigated over time.ResultsThe total and individual microbial genome counts were shown significantly increased after 180 days with no significant differences between abutment, non-abutment, or antagonist teeth. Streptococcus spp., Aggregatibacter actinomycetemcomitans, and other species associated to periodontitis (Peptostreptococcus anaerobius, Prevotella nigrescens, and Tannerella forsythia), as well as opportunistic Candida spp., were recovered in moderate counts. Abutment teeth presented higher values of gingival recession when compared with non-abutment or antagonist teeth, irrespectively time of sampling (p < 0.05). No significant differences were found between groups regarding bleeding on probing or probing depth over time.ConclusionsOverall, the microbial counts significantly increased after 6 months of denture loading for both abutment and non-abutment teeth with no significant differences regarding the microbial profile over time. Bleeding on probing and probing depth showed no significant difference between groups over time whereas gingival recession increased in the abutment teeth.  相似文献   

5.
ObjectiveThe aim of the study was to investigate the strength of the marginal ridge of tunnel preparations with different marginal ridge heights, using different restorative materials.Materials and methods120 sound premolars were randomly divided into three groups of standardized tunnel preparations with a remaining marginal ridge height of 1.5 mm, 2.5 mm and 3.5 mm, respectively. In each tunnel group, 10 teeth were filled with all four newly developed adhesive materials that had not previously been used in tunnel preparation: Ketac Aplicap, Fuji IX, Fuji II LC and Beautifil Flow F02. The control group comprised 10 sound teeth. All teeth were subjected to incremental dynamic force testing. Remaining marginal ridge height and restoration material were the independent variables. The mean maximum energy (MEI) score was the dependent variable. Data were analyzed, using one- and two-way analysis of variance. Scheffe's test and Student's t-test were used for comparison between groups.ResultsBoth restorative material (P < 0.0001) and remaining marginal ridge height (P < 0.0001) had a statistically significant effect on the mean MEI score of tunnel-prepared teeth. At the 2.5 mm of remaining marginal ridge height, no statistically significant difference in mean MEI score existed between Beautifil Flow F02-filled tunnel-prepared teeth and sound teeth.SignificancePremolars tunnel-restored with Beautifil Flow F02 at 2.5 mm distance from the marginal ridge were as strong as sound teeth.  相似文献   

6.
PurposeThis study aimed to compare the survival rates of remaining teeth between implant-supported fixed dentures (IFDs) and removable partial dentures (RPDs) in patients with large edentulous cases. The second goal was to assess the risk factors for remaining tooth loss.Materials and methodsThe study subjects were selected among those who received prosthodontic treatment at Okayama University Dental Hospital for their edentulous space exceeding at least four continuous missing teeth. Twenty-one patients were included in the IFD group and 82 patients were included in the RPD group. Survival rates of remaining teeth were calculated in three subcategories: (1) whole remaining teeth, (2) adjacent teeth to intended edentulous space, and (3) opposing teeth to intended edentulous space.ResultsThe ten-year cumulative survival rate of the whole remaining teeth was significantly higher in the IFD group (40.0%) than in the RPD group (24.4%). On the other hand, there was no significant difference between two groups in the survival rate of teeth adjacent or opposing to intended edentulous space. A Cox proportional hazard analysis revealed that RPD restoration and gender (male) were the significant risk factors for remaining tooth loss (whole remaining teeth).ConclusionsThese results suggest that IFD treatment can reduce the incidence of remaining tooth loss in large edentulous cases.  相似文献   

7.
ObjectivesTo determine the impact of hypodontia on the quality of life of adolescent and young adult patients, and, to assess the impact of restoring tooth spaces with resin bonded bridgework on quality of life of patients with hypodontia.MethodsIn a prospective study, 82 patients with a confirmed diagnosis of hypodontia participated. The primary outcome was oral health related quality of life (OHRQoL) and this was measured using the OHIP-49 prior to treatment. The pre-treatment sample was then divided into two groups: the test group (n = 40 patients) who had completed orthodontic treatment and had tooth spaces restored with resin bonded bridgework, and, a control group (n = 42 patients) who were still in the process of orthodontic treatment. All patients completed a follow-up OHIP-49, and between and within group comparisons made.ResultsThe pre-treatment sample included 43 females and 39 males, age ranged from 16 to 34 years (median age 19). Forty-three patients had more than 4 congenitally missing teeth and thirty-nine had ≤4 congenitally missing teeth. There were no differences between the groups prior to treatment. For the test group, there was a significant improvement in median OHIP summary scores (p < 0.001) after treatment. OHIP scores deteriorated to a significant degree for control subjects (p = 0.002). The effect sizes for the pre–post treatment change in both groups were moderate to large.ConclusionsHypodontia has a significant impact on oral health related quality of life. Provision of resin bonded bridges has a positive impact on oral health related quality of life of patients with hypodontia.  相似文献   

8.
PurposeThis study aimed to evaluate the effect of different storage periods in artificial saliva and thermal cycling on Knoop hardness of 8 commercial brands of resin denture teeth.MethodsEigth different brands of resin denture teeth were evaluated (Artplus group, Biolux group, Biotone IPN group, Myerson group, SR Orthosit group, Trilux group, Trubyte Biotone group, and Vipi Dent Plus group). Twenty-four teeth of each brand had their occlusal surfaces ground flat and were embedded in autopolymerized acrylic resin. After polishing, the teeth were submitted to different conditions: (1) immersion in distilled water at 37 ± 2 °C for 48 ± 2 h (control); (2) storage in artificial saliva at 37 ± 2 °C for 15, 30 and 60 days, and (3) thermal cycling between 5 and 55 °C with 30-s dwell times for 5000 cycles. Knoop hardness test was performed after each condition. Data were analyzed with two-way ANOVA and Tukey's test (α = .05).ResultsIn general, SR Orthosit group presented the highest statistically significant Knoop hardness value while Myerson group exhibited the smallest statistically significant mean (P < .05) in the control period, after thermal cycling, and after all storage periods. The Knoop hardness means obtained before thermal cycling procedure (20.34 ± 4.45 KHN) were statistically higher than those reached after thermal cycling (19.77 ± 4.13 KHN). All brands of resin denture teeth were significantly softened after storage period in artificial saliva.ConclusionStorage in saliva and thermal cycling significantly reduced the Knoop hardness of the resin denture teeth. SR Orthosit denture teeth showed the highest Knoop hardness values regardless the condition tested.  相似文献   

9.
Presence of pronounced incisal and occlusal wear in primary dentition is fairly common in children. Several factors are implied, however, the possible correlation of craniofacial growth to the occurrence of severe incisal tooth wear in children has not been described to date. Thus, this study was aimed to find any association between the craniofacial growth changes and the occurrence of severe incisal wear in children.Materials and methodsTwenty-seven sets of series of dental casts and corresponding lateral cephalograms are selected from the archive of Pediatric Dentistry, Department of Tokyo Medical and Dental University Hospital. Samples were divided into two groups based on the extent of incisal wear observed on the primary maxillary anterior teeth: slight attrition (N = 13) and severe attrition (n = 14) groups. Lateral cephalograms at early deciduous dentition at T1 (3.5 ± 0.6 years old) and late deciduous dentition at T2 (6.2 ± 0.6 years old) were manually traced and 17 linear and 22 angular measurements were measured with analyzing software (WinCeph ver.9). Annual growth rate for each sample was calculated to determine any significant difference between samples from two groups.ResultsSignificant horizontal growth of the mandible with both the reduction of anterior tooth height and increase of posterior tooth height were found in the severe attrition group. Reduction of upper incisor angle to FH plane and upper dental arch length were also related with the attrition of teeth.ConclusionsThe incisal tooth wear of deciduous teeth was significantly associated with the craniofacial growth changes.  相似文献   

10.
ObjectivesThe aim of this study was to investigate the relation between the remaining area of periodontal attachment and the attachment levels for each type of permanent teeth in a Chinese population by using micro-computed tomography (micro-CT) scans.DesignA total of 440 extracted permanent teeth (including each tooth type except for the third molars) were collected from a Chinese population and scanned using a micro-CT. The CT data were input into Mimics 15.01 to generate 3D tooth models. To simulate various attachment levels, the roots were virtually cut at 0, 2, 4, 6, 8, and 10 mm from the cemonto-enamel junction (CEJ). The net and percent remaining root surface area (RSA) were measured and calculated, and the data corresponding to attachment level were fitted to a linear function.ResultsA Linear function can perfectly fit in relating the simulated attachment level to the net and percent remaining RSA (R2 > 0.99, and p < 0.001 for each tooth type). For net remaining RSA, the slope of the linear function was steepest for maxillary first molars (b1 = −39.32) and least steep for mandibular central incisor (b1 = −13.08); whereas for the percentage of remaining RSA, the slopes (b1) were relatively within a narrow range, from −7.40 (maxillary canine) to −9.64 (maxillary first molars).ConclusionMicro-CT offers simple and precise technique for quantitative analysis of the RSA. The total amount and vertical distribution of the RSA varied by tooth type. Linear formulas can perfectly describe the relation between the attachment level and the net and percent remaining RSA.  相似文献   

11.
AimTo evaluate the microleakage of recently available glass ionomer based restorative materials (GC Fuji IX GP, GC Fuji VII, and Dyract) and compare their microleakage with the previously existing glass ionomer restorative materials (GC Fuji II LC) in primary and permanent teeth.MethodOne hundred and fifty (75 + 75) non-carious deciduous and permanent teeth were restored with glass ionomer based restorative materials after making class I cavities. Samples were subjected to thermocycling after storing in distilled water for 24 h. Two coats of nail polish were applied 1 mm short of restorative margins and samples sectioned buccolingually after storing in methylene blue dye for 24 h. Microleakage was assessed using stereomicroscope.ResultSignificant differences (P < 0.05) were found when inter group comparisons were done. Except when GC Fuji VII (Group III) was compared with GC Fuji II LC (Group II) and Dyract (Group IV), non-significant differences (P > 0.05) were observed. It was found that there was no statistically significant difference when the means of microleakage of primary teeth were compared with those of permanent teeth.ConclusionsGC Fuji IX GP showed maximum microleakage and GC Fuji VII showed least microleakage.  相似文献   

12.
During cone beam computed tomography (CBCT) scanning, intra-oral metallic objects may produce streak artefacts, which impair the occlusal surface of the teeth. This study aimed to determine the accuracy of replacement of the CBCT dentition with a more accurate dentition and to determine the clinical feasibility of the method. Impressions of the teeth of six cadaveric skulls with unrestored dentitions were taken and acrylic base plates constructed incorporating radiopaque registration markers. Each appliance was fitted to the skull and a CBCT performed. Impressions were taken of the dentition with the devices in situ and dental models were produced. These were CBCT-scanned and the images of the skulls and models imported into computer-aided design/computer-aided manufacturing (CAD/CAM) software and aligned on the registration markers. The occlusal surfaces of each dentition were then replaced with the occlusal image of the corresponding model. The absolute mean distance between the registration markers in the skulls and the dental models was 0.09 ± 0.02 mm, and for the dentition was 0.24 ± 0.09 mm. When the method was applied to patients, the distance between markers was 0.12 ± 0.04 mm for the maxilla and 0.16 ± 0.02 mm for the mandible. It is possible to replace the inaccurate dentition on a CBCT scan using this method and to create a composite skull which is clinically acceptable.  相似文献   

13.
《Archives of oral biology》2014,59(12):1342-1351
ObjectiveTo investigate if repeated holding and splitting of food morsel change the variability of force and jaw muscle activity in participants with natural dentition.MethodsTwenty healthy volunteers (mean age = 26.2 ± 3.9 years) participated in a single session divided into six series. Each series consisted of ten trials of a standardized behavioural task (total 60 trials) involving holding and splitting a flat-faced tablet (8 mm, 180 mg) placed on a bite force transducer with the anterior teeth. The hold and split forces along with the electromyographic (EMG) activity of the left and right masseter (MAL and MAR), left anterior temporalis (TAL) and digastric (DIG) muscles were recorded. A series (ten trials) of natural biting tasks was also performed before and after the six series of the behavioural task.ResultsThe mean hold force (P < 0.001) but not the mean split force (P = 0.590) showed significant effect of number of series. No significant effect of series was seen on the variability of hold and split force and the EMG activity except for the variability of EMG activity for MAL during the hold phase (P = 0.021) and DIG during the split phase (P < 0.001). The behavioural task had no effect on the EMG activity of the natural biting task.ConclusionThere was no evident optimization of jaw motor function in terms of reduction in the variability of bite force values and muscle activity, when this simple task was repeated up to sixty times in participants with normal intact periodontium.  相似文献   

14.
ObjectiveTo determine if full crown preparation causes an increase in pulpal blood flow (PBF), indicating inflammation, in human subjects.DesignThe experiments were carried out on 35 intact, mandibular posterior teeth in 13 subjects: 32 were abutments for 16 fixed bridges that replaced first molars; the other 3 were first premolars adjacent to abutment teeth that served as un-operated controls. Crown preparations were made using an air-rotor with water-spray under regional block anaesthesia (4% articaine with epinephrine 1:100,000). PBF was recorded with a laser Doppler flow meter (LDF) before and after administering the anaesthetic, with the LDF probe on the buccal enamel. PBF was then recorded from the abutment teeth with the probe on buccal dentine after preparing the buccal surfaces of both teeth, after completing the crown preparations, and after 1 and 7 days. PBF was also recorded from the buccal enamel of the control teeth on each occasion.ResultsThe mean ± S.D. PBF values before and after anaesthesia were 2.63 ± 2.13 and 2.42 ± 2.38P.U. respectively, which were not significantly different (Paired t-test). The mean values for the abutment teeth after buccal preparation, after complete crown preparation, and after 1 and 7 days were 5.20 ± 2.49, 4.53 ± 2.52, 4.92 ± 2.98 and 5.48 ± 2.65P.U. respectively. The 4 values for each tooth were not significantly different (two-way RM ANOVA). In the control group, the values under all six conditions were not significantly different.ConclusionsRegional block anaesthesia produced no change in PBF, nor did full-crown preparation, neither immediately after the procedure nor 1 and 7 days later.  相似文献   

15.
PurposeThis study explored the relationship between implant support and the denture-supporting area by comparing the stability of an implant-supported distal extension removable partial denture and a conventional distal extension removable partial denture.MethodsA model simulating a mandibular bilateral distal extension missing (#34–37 and #44–47) was fabricated using silicone impression material as soft tissue (2 mm thick) on an epoxy resin bone model. The denture base was reduced by 5 mm cutting part of both the retromolar pad and the lingual border. Loads of up to 5 kg were applied, and the pressure and displacement of the RPDs were simultaneously measured and analyzed using the Wilcoxon test (α < 0.05).ResultsThe pressure on the bilateral first molar and the middle areas of the implant-supported distal extension removable partial denture (ISRPD) was significantly less than on the conventional RPD (CRPD). As the supporting area of the denture base decreased, the pressure and the denture displacement of the CRPD were greater than for the ISRPD.ConclusionThis study indicated that implant placement at the distal edentulous ridge can prevent denture displacement of the distal extension bases, regardless of the supporting area of the denture base.  相似文献   

16.
ObjectiveTo compare the effectiveness of annual topical application of silver diamine fluoride (SDF) solution, semi-annual topical application of SDF solution, and annual application of a flowable high fluoride-releasing glass ionomer in arresting active dentine caries in primary teeth.MethodsA total of 212 children, aged 3–4 years, were randomly allocated to one of three groups for treatment of carious dentine cavities in their primary teeth: Gp1-annual application of SDF, Gp2-semi-annual application of SDF, and Gp3-annual application of glass ionomer. Follow-up examinations were carried out every six months to assess whether the treated caries lesions had become arrested.ResultsAfter 24 months, 181 (85%) children remained in the study. The caries arrest rates were 79%, 91% and 82% for Gp1, Gp2 and Gp3, respectively (p = 0.007). In the logistic regression model using GEE to adjust for clustering effect, higher caries arrest rates were found in lesions treated in Gp2 (OR = 2.98, p = 0.007), those in anterior teeth (OR = 5.55, p < 0.001), and those in buccal/lingual smooth surfaces (OR = 15.6, p = 0.004).ConclusionAnnual application of either SDF solution or high fluoride-releasing glass ionomer can arrest active dentine caries. Increasing the frequency of application to every 6 months can increase the caries arrest rate of SDF application.Clinical significanceArrest of active dentine caries in primary teeth by topical application of SDF solution can be enhanced by increasing the frequency of application from annually to every 6 months, whereas annual paint-on of a flowable glass ionomer can also arrest active dentine caries and may provide a more aesthetic outcome.  相似文献   

17.
PurposeThe aim of this study was to determine the prevalence of apical periodontitis and the technical quality of root canal fillings in a Palestinian sub-population.MethodsThe panoramic radiographs of 258 patients (142 females, 116 males) attending dental clinics in 2010 were examined to identify the presence of apical lesions associated with any remaining teeth, excluding third molars. The technical quality of root canal fillings was also evaluated by assessing apical extension from the radiographic apex. The panoramic radiographs were taken by a well-trained radiology assistant and evaluated by a radiologist and an endodontist. Statistical analysis was performed with the chi-square test with a significant level set at P < 0.05%.ResultsOf 6482 teeth examined radiographically, 978 (15.1%) had radiographic signs of apical periodontitis (AP). The prevalence of AP was 8.3% in teeth without filled roots and 59.5% (509/855) in root canal-treated teeth. The prevalence of AP and endodontic treatment increased with age and differed significantly (p < 0.05) between males and females. The majority (74.5%) of root canal fillings was performed inadequately, and most (77.2%) inadequate fillings were >2 mm short of the radiographic apex. The presence of AP was correlated significantly with poorly executed root canal fillings (p < 0.05).ConclusionsThe present study found a high prevalence and incidence of AP in association with root-filled teeth. The technical quality of many root canal treatments was unacceptable.  相似文献   

18.
ObjectivesThe purpose of this study was to determine the optical properties, color and contrast ratio (CR) of commercially available resin composites marketed for the restoration of whitened teeth.MethodsTwenty-six resin composites designed for restoration of whitened teeth and four shade B1 (control) were evaluated. Five resin composite disks (d = 12 mm, h = 1.54 mm) were fabricated for each shade of composite and were stored in water at 37 °C for at least 24 h. A colorimeter was used to measure specimen color over both white and black backgrounds. CIELAB and CIExyY color spaces were used. The CIELAB color notation system provides values for L*a*b*. The CIExyY system provides lightness and chromaticity values, where Y represents lightness and xy chromaticity. The contrast ratio (CR) was assessed using, CIE xyY, of the specimens against black (Yb) and white (Yw) backgrounds, with CR = Yb/Yw. The data for L*, a*, b* and CR were analyzed by one-way ANOVA, Tukey's test, and the correlation L* and CR was analyzed by Pearson correlation test (α = 0.05).ResultsSignificantly different L*, a*, b* values and CR were observed. Premise XL2 had the highest L* and CR values and Vit-l-escence PS had the lowest. Vit-l-escence PS had the highest a* value and Point 4XL2 had the lowest, Premise XL1 had the highest b* value and Supreme WB the lowest. The L* and CR correlation was positive and statistically significant.ConclusionsComposites designated for whitened teeth have different levels of color and contrast ratio. Awareness of the optical properties of the composites allows the operator to choose the appropriate materials to mimic the remaining tooth structure.  相似文献   

19.
ObjectivesTo investigate the bond strength between cpTi and low fusing porcelains after different treatments.Methods72 patterns were covered with a ceramic coating and invested with phosphate-bonded material (group A), another 72 were invested with magnesia material (group B) and all cast with cpTi. 31 solid castings were selected from each group. The castings of group B were ground and sandblasted, while the castings of group A were only sandblasted. Aluminum content of the metal surface was determined by EDS and castings were submitted to a 3-point bending test to determine the modulus of elasticity (E). The porcelains Duceratin Plus, Noritake Ti22 and Triceram were applied respectively and specimens were submitted to a 3-point bending test. The fracture mode and the remaining porcelain were determined by optical microscopy and SEM/EDS. Bond strength and fracture mode were calculated by two-way ANOVA.ResultsThe E of groups A and B was 98.3 GPa and 98.6 GPa respectively. The bond strength was 26 ± 3 MPa (Duceratin Plus), 28 ± 3 MPa (Noritake Ti22), 27 ± 2 MPa (Triceram) for group A and 24 ± 1 MPa, 29 ± 2 MPa, 27 ± 1 MPa for group B respectively. No significant differences were found for the same porcelain between the two groups (p < 0.05). A significant difference was found between Duceratin Plus and Noritake Ti22, for group B (p < 0.05). The mode of failure was mainly adhesive for all specimens. A significant reduction in aluminum was recorded in all subgroups.SignificanceThe special coating of patterns makes the Ti casting procedure inexpensive, without reducing the metal–ceramic bond strength.  相似文献   

20.
ObjectivesThis study investigated the influence of root variations on the root surface area (RSA) by using micro-CT scans.DesignA total of 228 extracted permanent teeth (2-rooted and single-rooted maxillary first premolars, mandibular first premolars with non-Tomes’ and Tomes’ roots, 2-rooted and 3-rooted mandibular first molars, and 2-rooted and C-shaped mandibular second molars) were collected in a Chinese population and scanned using a micro-CT. In Mimics 15.01, 3D tooth models were generated, and the net and percent remaining RSA at various simulated attachment levels were measured. The data corresponding to attachment level were fitted to a linear function.ResultsThe mean total RSA for different root forms decreased in the following order: 3-rooted > 2-rooted > C-shaped > single-rooted. However, the differences were statistically significant (p < 0.01) only for 2-rooted vs. single-rooted maxillary first premolars, and 2-rooted vs. C-shaped mandibular second molars. Linear functions can perfectly fit in relating the attachment level to the net and percent remaining RSA.ConclusionMicro-CT combined with Mimics software offers simple and precise technique for quantitative analysis of the RSA. Root variations may affect the total amount and vertical distribution of the net RSA. However, the degree of influence varies with the tooth type.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号