首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.
OBJECTIVE: To compare retrospectively high-resolution contrast-enhanced magnetic resonance angiography with centric k-space filling and digital subtraction angiography in the assessment of degree of carotid artery stenosis. METHODS: Two neuroradiologists independently evaluated 14 carotid arteries (in 7 patients), and the degree of carotid stenosis determined was compared to calculate interobserver reliability. Thirty-six carotid arteries (in 18 patients) were then assessed with both contrast-enhanced magnetic resonance angiography and digital subtraction angiography. The degree of stenosis was determined by consensus, and the findings of the 2 modalities were compared. RESULTS: Close interobserver agreement was found with an intraclass correlation coefficient of 0.98 (95% confidence interval 0.95-0.99). Sensitivity of 86% and specificity of 91% were found for contrast-enhanced magnetic resonance angiography detection of surgically significant carotid stenosis compared with digital subtraction angiography. The Spearman rank correlation test also found a significant correlation (R(s) = 0.90, p < 0.001) in the comparison of the classifications of degree of carotid artery stenosis. CONCLUSION: Contrast-enhanced magnetic resonance angiography shows excellent correlation with digital subtraction angiography for the evaluation of carotid artery disease and has the potential to replace it in the assessment of degree of carotid artery stenosis.  相似文献   

2.
OBJECTIVE: The purpose of this study is to determine the sensitivity, specificity, and clinical utility of classic 2D time-of-flight MR angiography (acquired with derated gradients) as an aid to predicting severe carotid stenosis. SUBJECTS AND METHODS: Our study population was composed of 68 patients, yielding 133 carotid bifurcations for analysis. A 2D time-of-flight MR angiography pulse sequence was modified to provide greater sensitivity for carotid stenosis, which resulted in visualization of a carotid stenosis with a 70% or greater diameter as a signal void. Contrast-enhanced MR angiography was performed with the elliptical centric view order. Multiple overlapping thin-slab acquisition (MOTSA) MR angiography was performed in select patients. Digital subtraction angiography was performed in 51 patients, and the findings were used as the gold standard. In the remaining patients, findings on carotid duplex Doppler sonography and at surgery and clinical follow-up were used as the gold standard. RESULTS: In 51 patients for whom a digital subtraction angiogram was available, we found that the sensitivity of classic 2D time-of-flight MR angiography for prediction of carotid stenosis with a 70% or greater diameter was 94%, and the specificity of the technique was 97%. In three patients with severe carotid stenosis, the stenoses that appeared as signal voids on the classic 2D time-of-flight MR angiography were underestimated on contrast-enhanced MR angiography. Severe stenosis was confirmed by subsequent digital subtraction angiography, surgical results, or both. Discrepancies between findings on MOTSA MR angiography and contrast-enhanced MR angiography were resolved with classic 2D time-of-flight MR angiography. Classic 2D time-of-flight MR angiography increased diagnostic confidence of a severe stenosis in three patients with focal internal carotid artery stenosis. CONCLUSION: Classic 2D time-of-flight MR angiography has a high sensitivity and specificity for predicting carotid bifurcation stenosis of 70% or greater diameter. These probability measures allowed the detection of three significant stenoses that would have been missed on contrast-enhanced MR angiography and provided greater diagnostic confidence than contrast-enhanced or MOTSA MR angiography alone.  相似文献   

3.
BACKGROUND AND PURPOSE: Since 1996, several preliminary studies have shown the usefulness of contrast material-enhanced MR angiography for imaging supraaortic vessels. The aim of this study was to compare the accuracy of contrast-enhanced 3D MR angiography with that of digital subtraction angiography (DSA) in the evaluation of carotid artery stenosis. METHODS: A blinded comparison of first-pass contrast-enhanced MR angiography with conventional DSA was performed in 120 patients (240 arteries). MR angiography was performed with a 1.5-T magnet with gradient overdrive equipment, by using a coronal radiofrequency-spoiled 3D fast low-angle-shot sequence after the intravenous injection of gadodiamide. The guidelines of the North American Symptomatic Carotid Endarterectomy Trial for measuring stenosis of the internal carotid artery were applied on maximum intensity projection (MIP) images and conventional catheter angiograms. RESULTS: Grading of stenoses on MR angiograms agreed with grading of stenoses on DSA images in 89% of arteries. In the severe stenosis group (70-99%), agreement was 93%. All internal carotid occlusions (n = 28) and seven of nine pseudo-occlusions were accurately detected with contrast-enhanced MR angiography. The correlation between MR angiography and DSA for determination of minimal, moderate, and severe stenoses and occlusion was statistically significant (r = 0.91, P<.001). CONCLUSIONS: This investigation with a large number of patients confirms that contrast-enhanced MR angiography could become a diagnostic alternative to DSA in the treatment of patients with carotid artery disease.  相似文献   

4.
BACKGROUND AND PURPOSE: MR angiography is primarily and increasingly used to assess intracranial arterial stenoocclusion. However, MR angiography can cause overestimation of stenosis. Although CT angiography is accurate, it has limitations. Our purpose was to determine whether the accuracy of combined MR angiography and CT angiography is equal to that of digital subtraction angiography (DSA) in measuring stenosis and detecting major intracranial arterial occlusion. METHODS: CT angiography and intraarterial DSA were prospectively performed in 18 patients with suspected intracranial stenoocclusive disease, as revealed with MR angiography. Before DSA, two reviewers independently assessed MR intracranial angiograms. Subsequently, they assessed CT angiograms with MR angiograms. Results were compared with DSA results. The degree of stenoocclusion was categorized; stenosis of 50% or more indicated stenoocclusive disease. After the blinded study, two radiologists retrospectively reviewed the angiographic findings. RESULTS: Stenoocclusive disease was identified in 18 of 198 intracranial arteries at DSA. MR angiography had a sensitivity of 92%, a specificity of 91%, and an accuracy of 91% for the identification of stenosis of 50% or more; the addition of CT angiography yielded values of 100%, 99%, and 99%, respectively. Stenotic grades with combined CT angiography and MR angiography agreed with those of DSA in 98% of cases. In the retrospective study, CT angiography did not always correctly delineate arterial lumina with circumferential calcification and cavernous portions of the internal carotid artery. CONCLUSION: In this investigation, the evaluation of suspected stenoocclusive diseases in major intracranial arteries, the accuracy of combined MR angiography and CT angiography is equal to that of DSA in most cases.  相似文献   

5.
A contrast-enhanced, gradient-echo 3D pulse sequence providing angiographic information in 24 s was tested in five healthy subjects and used prospectively in 21 patients for the investigation of the cervical arteries. Indications included suspected stenosis of the carotid (in 13), or vertebral arteries (in 1), carotid dissection (3), variants of the branches of the aortic arch (2) and extracranial carotid aneurysms (2). The results in all patients were compared with those of intra-arterial digital subtraction angiography (DSA). In patients with carotid stenosis, they were also compared with high-resolution 3D time-of-flight (TOF) MR angiography (MRA). Good quality MR angiograms of the neck vessels were obtained with the fast 3D sequence in 20 of the 21 patients. One claustrophobic patient was unable to co-operate. The degree of internal carotid artery (ICA) stenosis was graded correctly (compared to DSA) in 21 of 24 cases (87.5 %). Two mild stenoses were overestimated as moderate using the fast MR sequence and one high-grade stenosis was misdiagnosed as a complete occlusion. Carotid dissection was confirmed in one case and correctly excluded in two. Four extracranial ICA aneurysms in two patients, arterial variants and stenosis of the origin of the vertebral artery were correctly diagnosed using the contrast-enhanced MR angiogram. Three-dimensional TOF MRA was unsuccessful due to motion artefacts in half of the cases of ICA stenosis. Received: 6 August 1998 Accepted: 21 December 1998  相似文献   

6.
BACKGROUND AND PURPOSE: Although digital subtraction angiography (DSA) is the reference standard for assessing carotid arteries, it is uncomfortable for patients and has a small risk of disabling stroke and death. These problems have fueled the use of spiral CT angiography and MR angiography. We prospectively compared elliptic centric contrast-enhanced MR angiography and spiral CT angiography with conventional DSA for detecting carotid artery stenosis. METHODS: Eighty carotid arteries (in 40 symptomatic patients) were assessed. Elliptic centric MR and spiral CT angiographic data were reconstructed with maximum intensity projection and multiplanar reconstruction techniques. All patients had been referred for DSA evaluation on the basis of findings at Doppler sonography, which served as a screening method (degree of stenosis > or = 70% or inconclusive results). Degree of carotid stenosis estimated by using the three modalities was compared. RESULTS: Significant correlation with DSA was found for stenosis degree for both elliptic centric MR and spiral CT angiography; however, the correlation coefficient was higher for MR than for CT angiography (r = 0.98 vs r = 0.86). Underestimation of stenoses of 70-99% occurred in one case with elliptic centric MR angiography (a 70% stenosis was underestimated as 65%) and in nine cases with spiral CT angiography, in comparison to DSA findings. Overestimation occurred in two cases with MR angiography (stenoses of 65-67% were overestimated as 70-75%). With CT, overestimation occurred in seven cases; a stenosis of 60% in one case was overestimated as 70%. Both techniques confirmed the three cases of carotid occlusion. With elliptic centric MR angiography, carotid stenoses of 70% or greater were detected with high sensitivity, 97.1%; specificity, 95.2%; likelihood ratio (LR) for a positive test result, 20.4; and ratio of LR(+) to LR(-), -0.3. With spiral CT angiography, sensitivity, specificity, LR(+), and LR(+):LR(-) were 74.3%, 97.6%, 31.2, and 0.3, respectively. CONCLUSION: Elliptic centric contrast-enhanced MR angiography is more accurate than spiral CT angiography to adequately evaluate carotid stenosis. Furthermore, elliptic centric contrast-enhanced MR angiography appears to be adequate to replace conventional DSA in most patients examined.  相似文献   

7.
The authors compared the three-dimensional Fourier transform (3DFT) time-of-flight magnetic resonance (MR) angiograms in 38 patients initially studied with selective intraarterial digital subtraction angiography (DSA) for suspected arteriosclerotic disease of the carotid bifurcation. MR angiograms were successfully obtained in 65 of the 75 carotid arteries (87%) visualized with DSA. DSA and MR angiographic studies were assessed for percentage area stenosis by two independent observers on two occasions. Statistical tests indicated consistency in interpretation for each observer as well as between observers. No significant difference was found between the two modalities in ability to depict changes in percentage area stenosis. For the 32 right carotid arteries in the comparison, the median for the difference between MR angiography and intraarterial DSA was 1.83% (range, -22.38% to 55.60%); for the 33 visualized left carotid arteries, it was 0.00% (range, -20.55% to 49.95%). Receiver operating characteristic analysis indicated that technically adequate MR angiography may be a sensitive screening examination for stenoses.  相似文献   

8.
BACKGROUND AND PURPOSE: First-pass contrast-enhanced MR angiography has become the technique of choice for studying the carotid bifurcation, but this method has some limitations. We evaluated the clinical utility of performing 3D contrast-enhanced MR angiography in the axial plane immediately after performing angiography in the coronal plane. METHODS: Cervical carotid arteries of 80 consecutive patients were studied on a 1.5-T MR imager with phased-array coils. Coronal 3D MR angiography was performed after administering a bolus injection of contrast material (20 mL) with automatic triggering. This was immediately followed by an axial acquisition. We measured carotid diameters on the contrast-enhanced MR angiograms as well as on intra-arterial digital subtraction angiograms according to established criteria. We also evaluated original source MR angiograms. RESULTS: Angiograms obtained in the axial plane correlated better with the intra-arterial digital subtraction angiograms than did the coronal angiograms. When first-pass contrast-enhanced MR angiography was incomplete because of a failure of triggering, the second-phase acquisition provided sufficient image quality. Original source images suffered from ring artifacts, low axial resolution, and a low level of soft-tissue visualization. Axial-based source images showed flow-independent contrast filling to the patent lumen with sufficient visualization of plaque morphology, thickened arterial wall, and surrounding disease processes, such as tumors. CONCLUSION: With the addition of a 1-minute second-phase 3D acquisition in a different plane immediately after first-pass contrast-enhanced MR angiography, one can obtain a more accurate depiction of the carotid bifurcation, insurance against failure of triggering, and diagnostic source images.  相似文献   

9.
AIM: To compare the accuracy of ultrasound and two magnetic resonance (MR) angiographic techniques with catheter angiography in assessing atherosclerosis at the carotid bifurcation.MATERIALS AND METHODS: Forty patients with symptomatic carotid stenosis were studied by Doppler ultrasound, time-of-flight MR angiography, contrast-enhanced MR angiography and conventional catheter angiography. The degree of stenosis found on ultrasound and MR angiography was compared with the results of catheter angiography. Four different assessment methods were conducted for the MR angiographic data. Kappa, sensitivity and specificity (with confidence intervals) values were calculated for the US and MR angiography results compared to catheter angiography.RESULTS: Catheter angiography showed 12 internal carotid artery occlusions (15%), 34 severe (44%), 12 moderate (15%) and 20 mild stenoses (26%), using NASCET criteria.Ultrasound showed 65% sensitivity and 95% specificity in detecting surgically amenable lesions, whilst the MR angiographic techniques had sensitivities varying from 82-100%, and specificities from 95-100%.A moderate kappa value was calculated for the US data, whilst all MR techniques were found to show very good agreement with catheter angiography.CONCLUSION: This data suggests that MR angiography is more accurate than Doppler ultrasound in defining surgical lesions and has comparable accuracy to catheter angiography. The use of contrast-enhanced MR angiography is useful in certain situations but is not essential in all cases.  相似文献   

10.
PURPOSE: To compare the diagnostic accuracy of time-resolved three-dimensional contrast material-enhanced magnetic resonance (MR) angiography with that of conventional angiography for imaging the lower extremity vasculature. MATERIALS AND METHODS: Sixty-nine patients who were evaluated for possible surgical intervention underwent conventional angiography (ie, digital subtraction angiography [DSA]) and contrast-enhanced MR angiography (ie, time-resolved imaging of contrast kinetics [TRICKS]). Two independent, blinded readers evaluated vessel stenosis and occlusion at DSA and MR angiographic image readings. Sensitivity, specificity, positive and negative predictive values, and area under the receiver operating characteristic curve were analyzed with repeated-measures analysis of variance. The Cohen kappa test was performed to examine interreader variability. RESULTS: At pooled readings, contrast-enhanced MR angiography had a sensitivity of 78% and a specificity of 98% for detection of occlusion. For detection of significant stenosis (at least one > or = 50% stenosis), sensitivity and specificity were 77% and 91%, respectively. Interreader agreement was high for detection of both occlusion (kappa = 0.76) and significant stenosis (kappa = 0.68). Sensitivity increased as MR angiographic technical parameters were optimized. When improvements resulting from coil type and injection protocol were considered, the sensitivity and specificity of TRICKS MR angiography were 89% and 97%, respectively, for occlusion detection and 87% and 90%, respectively, for significant stenosis detection. CONCLUSION: Contrast-enhanced TRICKS MR angiography is a feasible and minimally invasive means of acquiring angiograms of the peripheral vasculature with high sensitivity and specificity.  相似文献   

11.
BACKGROUND AND PURPOSE: Contrast-enhanced MR angiography and extracranial color-coded duplex sonography are noninvasive, preoperative imaging modalities for evaluation of carotid artery stenosis. Innovative techniques and improvements in image quality require frequent reassessment of accuracy, reliability, and diagnostic value compared with those of digital subtraction angiography (DSA). We evaluated contrast-enhanced MR angiography and duplex sonography compared with DSA for detection of high-grade carotid artery stenoses. METHODS: Four readers, blinded to clinical symptoms and the outcome of other studies, independently evaluated stenoses on contrast-enhanced MR angiograms in 71 vessels of 39 symptomatic patients. Duplex sonography was also performed in all vessels. The severity of stenosis was defined according to North American Symptomatic Carotid Endarterectomy Trial criteria (0-29%, 30-69%, 70-99%, 100%). Results of both modalities were compared with the corresponding DSA findings. RESULTS: Contrast-enhanced MR angiography had a sensitivity and specificity of 94.9% and 79.1%, respectively, for the identification of carotid artery stenoses of 70% or greater. Sensitivity and specificity of duplex sonography were 92.9% and 81.9%, respectively. Combining data from both tests revealed a sensitivity and specificity of 100% and 81.4%, respectively, for concordant results (80% of vessels). CONCLUSION: Concordant results of contrast-enhanced MR angiography and duplex sonography increase the diagnostic sensitivity to 100%. The reliability of MR angiography is comparable to that of DSA. The combination of contrast-enhanced MR angiography and duplex sonography might be preferable over DSA for preoperative evaluation in most patients, thus reducing the risk of perioperative morbidity and improving the overall outcome.  相似文献   

12.
Fain SB  King BF  Breen JF  Kruger DG  Riederer SJ 《Radiology》2001,218(2):481-490
PURPOSE: To evaluate a high-spatial-resolution three-dimensional (3D) contrast material-enhanced magnetic resonance (MR) angiographic technique for detecting proximal and distal renal arterial stenosis. MATERIALS AND METHODS: Twenty-five patients underwent high-spatial-resolution small-field-of-view (FOV) 3D contrast-enhanced MR angiography of the renal arteries, which was followed several minutes later by more standard, large-FOV 3D contrast-enhanced MR angiography that included the distal aorta and iliac arteries. For both acquisitions, MR fluoroscopic triggering and an elliptic centric view order were used. Two readers evaluated the MR angiograms for grade and hemodynamic significance of renal arterial stenosis, diagnostic quality, and presence of artifacts. MR imaging results for each patient were compared with those of digital subtraction angiograms. RESULTS: The high-spatial-resolution small-FOV technique provided high sensitivity (97%) and specificity (92%) for the detection of renal arterial stenosis, including all four distal stenoses encountered. The portrayal of the segmental renal arteries was adequate for diagnosis in 19 (76%) of 25 patients. In 12% of the patients, impaired depiction of the segmental arteries was linked to motion. CONCLUSION: The combined high-spatial-resolution small-FOV and large-FOV MR angiographic examination provides improved spatial resolution in the region of the renal arteries while maintaining coverage of the abdominal aorta and iliac arteries.  相似文献   

13.
PURPOSE: To compare three-dimensional (3D) time-of-flight (TOF) MR angiography, contrast-enhanced MR angiography, digital subtraction angiography (DSA), and rotational angiography for depiction of stenosis. MATERIALS AND METHODS: The study had Ethics Committee approval, and each patient gave written informed consent. Forty-nine patients (18 women, mean age, 67.2 years +/- 9.1 [+/- standard deviation], and 31 men, mean age, 63.1 years +/- 8.0) with symptomatic stenosis of internal carotid artery (ICA) diagnosed at duplex ultrasonography underwent transverse 3D TOF MR angiography with sliding interleaved kY acquisition and coronal contrast-enhanced MR angiography, followed by DSA and rotational angiography within 48 hours. MR angiography was performed at 1.5-T with a cervical coil. Contrast-enhanced MR angiograms were obtained after a bolus injection of 20 mL of gadobenate dimeglumine. Maximum ICA stenosis on maximum intensity projection and source images was quantified according to NASCET criteria. Correlations for 3D TOF MR angiography, contrast-enhanced MR angiography, DSA, and rotational angiography were determined by means of cross tabulation, and accuracy for detection and grading of stenoses were calculated. Data were evaluated with analysis of variance, Wilcoxon signed rank test, and McNemar test, all at significance of P < .05. RESULTS: Ninety-eight ICAs were evaluated at contrast-enhanced MR angiography, DSA, and rotational angiography, and 97 were evaluated at 3D TOF MR angiography. Correlations for contrast-enhanced MR angiography, 3D TOF MR angiography, and DSA relative to rotational angiography were r2 = 0.9332, r2 = 0.9048, and r2 = 0.9255, respectively. Lower correlation (r2 = 0.8593) was noted for contrast-enhanced MR angiography and DSA. Respective sensitivity and specificity for detection of hemodynamically relevant stenosis relative to rotational angiography were 100% and 90% for contrast-enhanced MR angiography, 95.5% and 87.2% for 3D TOF MR angiography, and 88.6% and 100% for DSA. Four of 31 severe stenoses were underestimated at DSA, and three were underestimated at contrast-enhanced MR angiography. Three severe stenoses were underestimated at 3D TOF MR angiography, and one was misclassified as occluded. Of 13 moderate (50%-69%) stenoses, one was overestimated at contrast-enhanced MR angiography, two were underestimated and three overestimated at 3D TOF MR angiography, and two were underestimated at DSA. CONCLUSION: DSA results in an underestimation of ICA stenosis compared with rotational angiography. Contrast-enhanced MR angiography correlates best with rotational angiography.  相似文献   

14.
BACKGROUND AND PURPOSE: Established Doppler parameters for carotid stenosis assessment do not reflect North American Symptomatic Carotid Endarterectomy Trial (NASCET)-style methodology. We derived a Doppler parameter, termed sonographic NASCET index (SNI), and hypothesized that the SNI would provide greater angiographic correlation and better accuracy in predicting stenosis of 70% or greater than that of currently used peak systolic velocity (PSV) measurements. METHODS: Inclusion criteria of angiographically proved carotid stenoses of 40-95% and measured proximal and distal internal carotid artery Doppler PSV values were established. Occlusions and near occlusions were specifically excluded. Doppler and angiographic data meeting the inclusion criteria from 32 carotid bifurcations were identified; actual angiographic stenoses ranged 40-89%. SNI values were calculated for each vessel. PSV and SNI were correlated with angiography by using linear regression analysis. Accuracies of SNI and PSV in predicting stenosis of 70% or greater were compared at two thresholds. RESULTS: Correlation between SNI and angiography was superior to that between PSV and angiography (r2=0.64 vs 0.38). PSV and SNI values that corresponded to 70% angiographic stenosis were 345 cm/s and 45.5, respectively. Accuracy of PSV of 345 cm/s or greater in predicting stenosis of 70% or greater was 78%, compared with 88% for SNI of 45.5 or greater. The SNI value that corresponded to a PSV threshold of 250 cm/s was 33. Accuracy of PSV of 250 cm/s or greater in predicting stenosis of 70% or greater was 81%, compared with 88% for SNI of 33 or greater. CONCLUSION: Correlation between SNI and angiography was greater than that between PSV and angiography. Accuracy of SNI in predicting stenosis of 70% or greater was also superior to that of PSV at two thresholds. These results suggest that SNI may be a better predictor of high-grade carotid stenosis than is PSV.  相似文献   

15.
PURPOSETo evaluate the accuracy of CT angiography of occlusive disease of the carotid arteries using three-dimensional surface-rendered images alone and in conjunction with display of axial source images.METHODSForty-eight symptomatic patients had conventional angiography followed by CT angiography within 24 hours. Images of 96 carotid arteries were acquired using contrast-enhanced spiral CT. Image postprocessing was performed on a free-standing workstation to produce 3-D shaded surface display (SSD) images. Two readers independently evaluated the CT angiographic (SSD) images and then reevaluated each case while simultaneously reviewing the SSD and axial source images. Digital subtraction angiograms were evaluated in a separate session and eventually compared with CT angiograms. All evaluations were performed under blinded conditions to control for reader bias.RESULTSSSD images alone underestimated stenosis relative to angiograms whereas combined SSD and axial images did not.CONCLUSIONSSD angiograms in conjunction with the source images are better than SSD images alone in estimating the degree of stenosis in carotid artery disease.  相似文献   

16.
PURPOSE: To prospectively compare the diagnostic accuracies of color duplex ultrasonography (US) and contrast material-enhanced magnetic resonance (MR) angiography and to assess interobserver agreement regarding contrast-enhanced MR angiographic findings in patients suspected of having peripheral arterial disease (PAD). MATERIALS AND METHODS: The institutional review board approved the study, and all patients provided signed informed consent. Two hundred ninety-five patients referred for diagnostic and preinterventional work-up of PAD with duplex US also underwent gadolinium-enhanced MR angiography. Data sets were reviewed for presence or absence of 50% or greater luminal reduction, which indicated hemodynamically significant stenosis, and to determine interobserver agreement. At duplex US, a peak systolic velocity ratio of 2.5 or greater indicated significant stenosis. Primary outcome measures were differences between duplex US and contrast-enhanced MR angiography in sensitivity and specificity for detection of significant stenosis, as assessed with the McNemar test, and interobserver agreement between the two contrast-enhanced MR angiogram readings, expressed as quadratic weighted kappa values. Intraarterial digital subtraction angiography (DSA) was the reference standard. RESULTS: Two hundred forty-nine patients had at least one hemodynamically significant stenotic lesion at contrast-enhanced MR angiography, duplex US, or both examinations. One hundred fifty-two patients underwent intraarterial DSA. The quadratic weighted kappa for agreement regarding the presence of 50% or greater stenosis at contrast-enhanced MR angiography was 0.89 (95% confidence interval [CI]: 0.87, 0.91). Sensitivity of duplex US was 76% (95% CI: 69%, 82%); specificity, 93% (95% CI: 91%, 95%); and accuracy, 89%. Sensitivity and specificity of contrast-enhanced MR angiography were 84% (95% CI: 78%, 89%) and 97% (95% CI: 95%, 98%), respectively; accuracy was 94%. Sensitivity (P = .002) and specificity (P = .03) of contrast-enhanced MR angiography were significantly higher. CONCLUSION: Results of this prospective comparison between contrast-enhanced MR angiography and duplex US provide evidence that contrast-enhanced MR angiography is more sensitive and specific for diagnosis and preinterventional work-up of PAD.  相似文献   

17.
BACKGROUND AND PURPOSE: Compared with the single-detector technique, multi-detector row CT angiography permits larger anatomic coverage that includes both the epiaortic and entire carotid circulations. We evaluated the accuracy of multi-detector row CT angiography by using multiplanar reformation (MPR) for measuring carotid artery diameters compared with that of rotational angiography. We also evaluated the diagnostic performance of CT angiography compared with digital subtraction angiography (DSA). METHODS: In 35 patients, CT angiograms of 70 carotid arteries were compared with DSA images, and CT angiograms of 33 carotid arteries were compared with rotational angiograms. CT angiographic interpretation was performed first interactively at a workstation. Diameter measurements of normal and stenosed carotid arteries were performed on cross-sectional and oblique sagittal MPRs. Degree of stenosis was calculated per North American Symptomatic Carotid Endarterectomy Trial criteria independently by two observers for each technique. RESULTS: Degree of stenosis was slightly underestimated with CT angiography, with mean differences (+/- SD) per observer of 6.9 +/- 17.6% and 10.7 +/- 16.1% for cross-sectional and 2.8 +/- 19.2% and 9.1 +/- 16.8% for oblique sagittal MPRs compared with rotational angiography. CT angiography was somewhat inaccurate for measuring the absolute minimal diameter of high-grade stenoses. On symptomatic sides (n = 35), interactive CT angiographic interpretation combined with MPR measurements for lesions with a visual estimate of 50% or greater stenosis achieved a sensitivity of 95% (20/21) and specificity of 93% (13/14) in the detection of carotid stenosis (>/= 50%) verified with DSA. CONCLUSION: Regardless of slight underestimation of carotid stenosis with CT angiography compared with rotational angiography, diagnostic performance of CT angiography with interactive interpretation proved to be good. Also, the method is highly sensitive for detection of carotid artery stenosis, indicating the suitability of CT angiography as a screening method for symptomatic patients. For hemodynamically significant stenoses revealed by CT angiographic screening, conventional angiography still seems to be necessary.  相似文献   

18.
OBJECTIVE: The diagnostic performance of a three-dimensional MR angiography-based strategy was assessed with regard to its ability to characterize the arterial vasculature from the aortic bifurcation to the lower extremity runoff vessels. A single-injection, two-station protocol in combination with a lower-extremity vascular coil was used. SUBJECTS AND METHODS: Both conventional digital subtraction angiography and three-dimensional contrast-enhanced MR angiography with a dedicated peripheral vascular coil were performed in 61 patients with suspected peripheral vascular disease. In a prospective analysis, one reviewer evaluated the digital subtraction angiographic images and a second reviewer evaluated the MR angiographic images; both were unaware of the results of the other imaging technique. Each vascular segment (29 segments per patient) was evaluated for the presence of occlusive vessel disease. The following grading system was applied: 0, normal; 1, vessel irregularity with a luminal reduction of less than 10%; 2, mild stenosis (lumen reduction, 10-49%); 3, severe stenosis (lumen reduction, 50-99%); and 4, occlusion (lumen reduction, 100%). In 11 patients surgical graft patency was assessed. RESULTS: MR angiography provided an image quality comparable with that of digital subtraction angiography. Overall sensitivity and specificity for MR angiography were 92% and 96.6%, respectively, for the detection of hemodynamically significant disease and 92.3% and 99.4%, respectively, for the detection of occlusions. CONCLUSION: Two-station contrast-enhanced three-dimensional MR angiography with a dedicated lower-extremity vascular coil proved effective enough to consider it as a noninvasive alternative to digital subtraction angiography in the assessment of the pelvic and lower extremity arterial vasculature.  相似文献   

19.
Temporal/energy (hybrid) subtraction is a technique for removing soft-tissue motion artifact from digital subtraction angiograms. The diagnostic utility of hybrid subtraction for i.v. and intraarterial angiography was assessed in the first 9 months of operation of a dedicated production system. In i.v. carotid arteriography (N = 127), hybrid subtraction (H) provided a double-profile projection of the carotid bifurcation in an additional 14% of studies, compared with temporal subtraction (T) alone (H79:T48, p less than 0.001). However, a change in estimated percent stenosis or additional diagnostic information occurred in only 2% of studies. In i.v. abdominal arteriography (N = 23), hybrid subtraction, compared with temporal subtraction, provided a diagnostic examination in an additional 14% of studies (H20:T17); however, this difference is not statistically significant. An additional three i.v. abdominal angiograms were nondiagnostic. In intraarterial abdominal (N = 98) and pelvic (N = 60) angiography, hybrid subtraction provided a diagnostic examination in an additional 5% of studies (abdomen H94:T90, pelvis H58:T56); this difference was not statistically significant. An additional 5% of all intraarterial abdominal and pelvic digital subtraction angiographic studies were considered nondiagnostic. Hybrid subtraction provides a double-profile view of the carotid bifurcation in a significant number of patients. However, apart from some potential for improved i.v. abdominal arteriography, hybrid subtraction does not result in significant improvement in comparison to conventional temporal-subtraction techniques.  相似文献   

20.
Findings of two-dimensional time-of-flight magnetic resonance (MR) angiography projection angiograms were prospectively compared with those of color Doppler sonography by using angiography as a standard in 23 consecutive patients (42 carotid bifurcations) to evaluate their utility in determining the presence of carotid artery stenosis. MR angiography helped detect 50% or greater lumen diameter stenosis (sensitivity, 0.96; specificity, 0.64). Color Doppler sonography with 1.25 m/sec peak systolic velocity as a threshold had a sensitivity of 0.96 and a specificity of 0.71. Statistical analysis showed a correlation between percentage of lumen diameter narrowing and the length of the zone of signal intensity loss with MR angiography (r = .69; P less than .0001). A stronger relationship was obtained between angiographic narrowing and peak systolic velocity derived from color Doppler sonography (r = .80; P less than .0001). Two-dimensional time-of-flight MR angiography displayed as projection angiograms and combined with carotid artery and combined with carotid artery sonography is a useful approach for helping detect and potentially grade the severity of stenoses of the carotid artery.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号