首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 12 毫秒
1.
Cerebrovascular reactivity (CVR) can give insight into the cerebrovascular function. CVR can be estimated by measuring a blood‐oxygen‐level‐dependent (BOLD) response combined with breath‐holding (BH). The reproducibility of this technique has been addressed and existing studies have focused on short‐term reproducibility using a 3 T magnetic resonance imaging (MRI) system. However, little is known about the long‐term reproducibility of this procedure and the corresponding reproducibility using a 1.5 T MRI system. Here, we systematically examined the short‐ and long‐term reproducibility of BOLD responses to BH across field strengths. Nine subjects participated in three MRI sessions separated by 30 minutes (sessions 1 and 2: short term) and 68–92 days (sessions 1 and 3, long term) at both 1.5 and 3 T MRI. Our findings revealed that significant differences between field strengths were detected in the activated gray matter volume and BOLD signal change (both P < 0.001), with smaller magnitudes at 1.5 T. However, activation patterns were reproducible, independent of the time interval, brain region or field strength. All interscan coefficient of variation values were below the 33% fiducial limit, and the intraclass correlation coefficient values were above 0.4, which is usually considered the acceptability limit in functional studies. These findings suggest that the response of BOLD signal to BH for assessing CVR is reproducible over time at 1.5 and 3 T. This technique can be considered a tool for monitoring longitudinal changes in patients with cerebrovascular diseases, and its use should be encouraged for clinical 1.5 T MRI systems.  相似文献   

2.
A rapid method of simultaneous T1 and T2 measurement is presented which uses a segmented echo‐planar readout with varying repetition times (TR) and echo times (TE). This method is useful in T1 mapping for analysis of dynamic contrast enhanced MRI (DCE‐MRI), where T1 can be used to estimate contrast agent concentration. In the application of this method to dynamic imaging, the equilibrium magnetization is measured on pre‐contrast images and incorporated into post‐contrast T1 calculations for improved accuracy. Simultaneous T2 measurement allows correction of T2 effects in the T1 map which may occur at high contrast agent concentrations, and is performed without significant imaging time penalty. Phantom and in vivo results show the usefulness of this technique for analysis of contrast enhancement kinetics. Accurate rapid contrast agent concentration measurement may be useful for analyzing the distribution and kinetics of contrast agents or labeled pharmaceuticals. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

3.
We present a non‐invasive MRI approach for assessing the water proton resonance frequency (PRF) shifts associated with changes in temperature. This method is based on water saturation shift referencing (WASSR), a method first developed for assessing B0 field inhomogeneity. Temperature‐induced water PRF shifts were determined by estimating the frequency of the minimum intensity of the water direct saturation spectrum at each temperature using Lorentzian line‐shape fitting. The change in temperature was then calculated from the difference in water PRF shifts between temperatures. Optimal acquisition parameters were first estimated using simulations and later confirmed experimentally. Results in vitro and in vivo showed that the temperature changes measured using the temperature‐responsive WASSR (T‐WASSR) were in good agreement with those obtained with MR spectroscopy or phase‐mapping‐based water PRF measurement methods,. In addition, the feasibility of temperature mapping in fat‐containing tissue is demonstrated in vitro. In conclusion, the T‐WASSR approach provides an alternative for non‐invasive temperature mapping by MRI, especially suitable for temperature measurements in fat‐containing tissues. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

4.
The integrity of the blood–brain barrier (BBB) is critical to normal brain function. Traditional techniques for the assessment of BBB disruption rely heavily on the spatiotemporal analysis of extravasating contrast agents. However, such methods based on the leakage of relatively large molecules are not suitable for the detection of subtle BBB impairment or for the performance of repeated measurements in a short time frame. Quantification of the water exchange rate constant (WER) across the BBB using strictly intravascular contrast agents could provide a much more sensitive method for the quantification of the BBB integrity. To estimate WER, we have recently devised a powerful new method using a water exchange index (WEI) biomarker and demonstrated BBB disruption in an acute stroke model. Here, we confirm that WEI is sensitive to even very subtle changes in the integrity of the BBB caused by: (i) systemic hypercapnia and (ii) low doses of a hyperosmolar solution. In addition, we have examined the sensitivity and accuracy of WEI as a biomarker of WER using computer simulation. In particular, the dependence of the WEI–WER relation on changes in vascular blood volume, T1 relaxation of cellular magnetization and transcytolemmal water exchange was explored. Simulated WEI was found to vary linearly with WER for typically encountered exchange rate constants (1–4 Hz), regardless of the blood volume. However, for very high WER (>5 Hz), WEI became progressively more insensitive to increasing WER. The incorporation of transcytolemmal water exchange, using a three‐compartment tissue model, helped to extend the linear WEI regime to slightly higher WER, but had no significant effect for most physiologically important WERs (WER < 4 Hz). Variation in cellular T1 had no effect on WEI. Using both theoretical and experimental approaches, our study validates the utility of the WEI biomarker for the monitoring of BBB integrity. Copyright © 2012 John Wiley & Sons, Ltd.  相似文献   

5.
Fast apparent transverse relaxation (short T2*) is a common obstacle when attempting to perform quantitative 1H MRI of the lungs. While T2* times are longer for pulmonary hyperpolarized (HP) gas functional imaging (in particular for gaseous 129Xe), T2* can still lead to quantitative inaccuracies for sequences requiring longer echo times (such as diffusion weighted images) or longer readout duration (such as spiral sequences). This is especially true in preclinical studies, where high magnetic fields lead to shorter relaxation times than are typically seen in human studies. However, the T2* of HP 129Xe in the most common animal model of human disease (mice) has not been reported. Herein, we present a multi‐echo radial flyback imaging sequence and use it to measure HP 129Xe T2* at 7 T under a variety of respiratory conditions. This sequence mitigates the impact of T1 relaxation outside the animal by using multiple gradient‐refocused echoes to acquire images at a number of effective echo times for each RF excitation. After validating the sequence using a phantom containing water doped with superparamagnetic iron oxide nanoparticles, we measured the 129Xe T2* in vivo for 10 healthy C57Bl/6 J mice and found T2* ~ 5 ms in the lung airspaces. Interestingly, T2* was relatively constant over all experimental conditions, and varied significantly with sex, but not age, mass, or the O2 content of the inhaled gas mixture. These results are discussed in the context of T2* relaxation within porous media.  相似文献   

6.
Ferumoxytol‐enhanced MRI holds potential for the non‐invasive assessment of vascular architecture using estimates of cerebral blood volume (CBV). Ferumoxytol specifically enables steady‐state imaging with extended acquisition times, for substantial improvements in resolution and contrast‐to‐noise ratio. With such data, quantitative susceptibility mapping (QSM) can be used to obtain images of local tissue magnetic susceptibility and hence estimate the increase in blood susceptibility after administration of a contrast agent, which in turn can be correlated to tissue CBV. Here, we explore the use of QSM for CBV estimation and compare it with R2* (1/T2*)‐based results. Institutional review board approval was obtained, and all subjects provided written informed consent. For this prospective study, MR images were acquired on a 3.0 T scanner in 19 healthy subjects using a multiple‐echo T2*‐weighted sequence. Scanning was performed before and after the administration of two doses of ferumoxytol (1 mg FE/kg and 4 mg FE/kg). Different QSM approaches were tested on numerical phantom simulations. Results showed that the accuracy of magnetic susceptibility measurements improved with increasing image resolution and decreasing vascular density. In vivo changes in magnetic susceptibility were measured after the administration of ferumoxytol utilizing QSM, and significantly higher QSM‐based CBV was measured in gray matter compared with white matter. QSM‐ and R2*‐based CBV estimates correlated well, with similar average values, but a larger variance was found in QSM‐based estimates.  相似文献   

7.
Immediate and certain determination of the treatable area is important for choosing risky treatments such as thrombolysis for brain ischemia, especially in the super‐acute phase. Although it has been suggested that the mismatch between regions displaying ‘large abnormal perfusion’ and ‘small abnormal diffusion’ indicates a treatable area on an MRI, it has also been reported that the mismatch region is an imperfect approximation of the treatable region named the ‘penumbra’. Manganese accumulation reflecting calcium influx into cells was reported previously in a middle cerebral artery occlusion (MCAO) model using activity‐induced manganese‐enhanced (AIM) MRI. However, in the super‐acute phase, there have been no reports about mismatches between areas showing changes to the apparent diffusion coefficient (ADC) and regions that are enhanced in AIM MRI. It is expected that the AIM signal can be enhanced immediately after cerebral ischemia in the necrotic core region due to calcium influx. In this study, a remote embolic rat model, created using titanium‐oxide macrospheres, was used to observe necrotic neural responses in the super‐acute phase after ischemia. In addition, images were evaluated by comparison between ADC, AIM MRI, and histology. The signal enhancement in AIM MRI was detected at 2 min after the cerebral infarction using a remote embolic method. The enhanced area on the AIM MRI was significantly smaller than that on the ADC map. The tissue degeneration highlighted by histological analysis corresponded more closely to the enhanced area on the AIM MRI than that on the ADC map. Thus, the manganese‐enhanced region in brain ischemia might indicate ‘necrotic’ irreversible tissue that underwent calcium influx. Copyright © 2009 John Wiley & Sons, Ltd.  相似文献   

8.
Here, we show that the sensitivity of 31P MRSI of 31P spins J‐coupled to protons can be increased by almost a factor of three when compared with an optimal direct detection free induction decay. By direct detection integrated with multi‐echo polarization transfer (DIMEPT), multiple signals from polarization transfer and direct detection can be acquired in one repetition time, with minimal mutual interference, provided that the number of refocusing pulses in the multi‐echo polarization transfer part is even. The DIMEPT sequence was implemented on a 7‐T body scanner and tested on a phantom and on the breasts of five healthy volunteers. The in vivo signal‐to‐noise ratio (SNR) enhancement for the J‐coupled phosphomonoesters was 270% when compared with an Ernst angle pulse‐acquire sequence. However, the phosphodiester signals, presumably mainly mobile phospholipids, had T2 values that were too short to be enhanced. Uncoupled 31P spins, with sufficiently long T2 values, such as inorganic phosphate, were SNR enhanced by a factor of 1.9 relative to an Ernst‐angle excitation pulse‐acquire sequence by multi‐echo direct detection. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

9.
Being able to finely characterize the spinal cord (SC) microstructure and its alterations is a key point when investigating neural damage mechanisms encountered in different central nervous system (CNS) pathologies, such as multiple sclerosis, amyotrophic lateral sclerosis or myelopathy. Based on novel methods, including inhomogeneous magnetization transfer (ihMT) and dedicated SC probabilistic atlas post‐processing, the present study focuses on the in vivo characterization of the healthy SC tissue in terms of regional microstructure differences between (i) upper and lower cervical vertebral levels and (ii) sensory and motor tracts, as well as differences attributed to normal aging. Forty‐eight healthy volunteers aged from 20 to 70 years old were included in the study and scanned at 3 T using axial high‐resolution T2*‐w imaging, diffusion tensor imaging (DTI) and ihMT, at two vertebral levels (C2 and C5). A processing pipeline with minimal user intervention, SC segmentation and spatial normalization into a reference space was implemented in order to assess quantitative morphological and structural parameters (cross‐sectional areas, scalar DTI and MT/ihMT metrics) in specific white and gray matter regions of interest. The multi‐parametric MRI metrics collected allowed upper and lower cervical levels to be distinguished, with higher ihMT ratio (ihMTR), higher axial diffusivity (λ) and lower radial diffusivity (λ) at C2 compared with C5. Significant differences were also observed between white matter fascicles, with higher ihMTR and lower λ in motor tracts compared with posterior sensory tracts. Finally, aging was found to be associated with significant metric alterations (decreased ihMTR and λ). The methodology proposed here, which can be easily transferred to the clinic, provides new insights for SC characterization. It bears great potential to study focal and diffuse SC damage in neurodegenerative and demyelinating diseases. Copyright © 2016 John Wiley & Sons, Ltd.  相似文献   

10.
The objective of this study is to develop improved methods for renal blood oxygenation level dependent (BOLD) imaging. T2* mapping of the kidneys, or renal BOLD imaging, may depict renal oxygen levels and may be valuable as a noninvasive means of following the progression of renal disease. Current renal BOLD data is limited by imaging in a single breath hold, which results in low resolution and low signal‐to‐noise ratio (SNR). We compare a new free‐breathing renal BOLD method with conventional breath‐hold BOLD (BH‐BOLD). A multi‐echo GRE sequence with continuous prospective respiratory navigation and real‐time feedback was developed that allows high resolution and high SNR renal BOLD imaging with constant sequence repetition time (TR) during free‐breathing BOLD (FB‐BOLD). The sequence was evaluated in 10 normal volunteers and compared with conventional BH‐BOLD. Scan time for the FB‐BOLD sequence was approximately three minutes, compared with 15 seconds for the BH‐BOLD sequence. SNR of source images and residual error of T2* fitting were compared between the two methods. The FB‐BOLD sequence produced motion‐free T2* maps of the kidneys with SNR 1.9 times higher than BH‐BOLD images. Residual error of T2* fitting was consistently lower in the right kidney with FB‐BOLD (30% less than BH‐BOLD) but higher in the left kidney (80% more than BH‐BOLD), likely related to placement of the navigator on the right hemidiaphragm. A free‐breathing prospectively navigated renal BOLD sequence allows flexible tradeoff between scan time, resolution, and SNR.  相似文献   

11.
Fractional anisotropy (FA) obtained by diffusion tensor imaging (DTI) can be used to image the kidneys without any contrast media. FA of the medulla has been shown to correlate with kidney function. It is expected that higher spatial resolution would improve the depiction of small structures within the kidney. However, the achievement of high spatial resolution in renal DTI remains challenging as a result of respiratory motion and susceptibility to diffusion imaging artefacts. In this study, a targeted field of view (TFOV) method was used to obtain high‐resolution FA maps and colour‐coded diffusion tensor orientations, together with measures of the medullary and cortical FA, in 12 healthy subjects. Subjects were scanned with two implementations (dual and single kidney) of a TFOV DTI method. DTI scans were performed during free breathing with a navigator‐triggered sequence. Results showed high consistency in the greyscale FA, colour‐coded FA and diffusion tensors across subjects and between dual‐ and single‐kidney scans, which have in‐plane voxel sizes of 2 × 2 mm2 and 1.2 × 1.2 mm2, respectively. The ability to acquire multiple contiguous slices allowed the medulla and cortical FA to be quantified over the entire kidney volume. The mean medulla and cortical FA values were 0.38 ± 0.017 and 0.21 ± 0.019, respectively, for the dual‐kidney scan, and 0.35 ± 0.032 and 0.20 ± 0.014, respectively, for the single‐kidney scan. The mean FA between the medulla and cortex was significantly different (p < 0.001) for both dual‐ and single‐kidney implementations. High‐spatial‐resolution DTI shows promise for improving the characterization and non‐invasive assessment of kidney function. © 2014 The Authors. NMR in Biomedicine published by John Wiley & Sons, Ltd.  相似文献   

12.
Arterial transit time (ATT) prolongation causes an error of cerebral blood flow (CBF) measurement during arterial spin labeling (ASL). To improve the accuracy of ATT and CBF in patients with prolonged ATT, we propose a robust ATT and CBF estimation method for clinical practice. The proposed method consists of a three‐delay Hadamard‐encoded pseudo‐continuous ASL (H‐pCASL) with an additional‐encoding and single‐delay with long‐labeled long‐delay (1dLLLD) acquisition. The additional‐encoding allows for the reconstruction of a single‐delay image with long‐labeled short‐delay (1dLLSD) in addition to the normal Hadamard sub‐bolus images. Five different images (normal Hadamard 3 delay, 1dLLSD, 1dLLLD) were reconstructed to calculate ATT and CBF. A Monte Carlo simulation and an in vivo study were performed to access the accuracy of the proposed method in comparison to normal 7‐delay (7d) H‐pCASL with equally divided sub‐bolus labeling duration (LD). The simulation showed that the accuracy of CBF is strongly affected by ATT. It was also demonstrated that underestimation of ATT and CBF by 7d H‐pCASL was higher with longer ATT than with the proposed method. Consistent with the simulation, the 7d H‐pCASL significantly underestimated the ATT compared to that of the proposed method. This underestimation was evident in the distal anterior cerebral artery (ACA; P = 0.0394) and the distal posterior cerebral artery (PCA; 2 P = 0.0255). Similar to the ATT, the CBF was underestimated with 7d H‐pCASL in the distal ACA (P = 0.0099), distal middle cerebral artery (P = 0.0109), and distal PCA (P = 0.0319) compared to the proposed method. Improving the SNR of each delay image (even though the number of delays is small) is crucial for ATT estimation. This is opposed to acquiring many delays with short LD. The proposed method confers accurate ATT and CBF estimation within a practical acquisition time in a clinical setting.  相似文献   

13.
Copolymerization of carbon dioxide (CO2) and propylene oxide (PO) is employed to generate amphiphilic polycarbonate block copolymers with a hydrophilic poly(ethylene glycol) (PEG) block and a nonpolar poly(propylene carbonate) (PPC) block. A series of poly(propylene carbonate) (PPC) di‐ and triblock copolymers, PPC‐b‐PEG and PPC‐b‐PEG‐b‐PPC, respectively, with narrow molecular weight distributions (PDIs in the range of 1.05–1.12) and tailored molecular weights (1500–4500 g mol?1) is synthesized via an alternating CO2/propylene oxide copolymerization, using PEG or mPEG as an initiator. Critical micelle concentrations (CMCs) are determined, ranging from 3 to 30 mg L?1. Non‐ionic poly(propylene carbonate)‐based surfactants represent an alternative to established surfactants based on polyether structures.

  相似文献   


14.
Magnetic resonance imaging offers a means of observing the internal structure of the brain where traditional procedures of embedding, sectioning, staining, mounting, and microscopic examination of thousands of sections are not practical. Furthermore, internal structures can be analyzed in their precise quantitative spatial interrelationships, which is difficult to accomplish after the spatial distortions often accompanying histological processing. For these reasons, magnetic resonance imaging makes specimens that were traditionally difficult to analyze, more accessible. In the present study, images of the brain of a white whale (Beluga) Delphinapterus leucas were scanned in the coronal plane at 119 antero‐posterior levels. From these scans, a computer‐generated three‐dimensional model was constructed using the programs VoxelView and VoxelMath (Vital Images, Inc.). This model, wherein details of internal and external morphology are represented in three‐dimensional space, was then resectioned in orthogonal planes to produce corresponding series of “virtual” sections in the horizontal and sagittal planes. Sections in all three planes display the sizes and positions of such structures as the corpus callosum, internal capsule, cerebral peduncles, cerebral ventricles, certain thalamic nuclear groups, caudate nucleus, ventral striatum, pontine nuclei, cerebellar cortex and white matter, and all cerebral cortical sulci and gyri. Anat Rec 262:429–439, 2001. © 2001 Wiley‐Liss, Inc.  相似文献   

15.
Risk stratification, based on the Gleason score (GS) of a prostate biopsy, is an important decision‐making tool in prostate cancer management. As low‐grade disease may not need active intervention, the ability to identify aggressive cancers on imaging could limit the need for prostate biopsies. We assessed the ability of multiparametric MRI (mpMRI) in pre‐biopsy risk stratification of men with prostate cancer. One hundred and twenty men suspected to have prostate cancer underwent mpMRI (diffusion MRI and MR spectroscopic imaging) prior to biopsy. Twenty‐six had cancer and were stratified into three groups based on GS: low grade (GS ≤ 6), intermediate grade (GS = 7) and high grade (GS ≥ 8). A total of 910 regions of interest (ROIs) from the peripheral zone (PZ, range 25–45) were analyzed from these 26 patients. The metabolite ratio [citrate/(choline + creatine)] and apparent diffusion coefficient (ADC) of voxels were calculated for the PZ regions corresponding to the biopsy cores and compared with histology. The median metabolite ratios for low‐grade, intermediate‐grade and high‐grade cancer were 0.29 (range: 0.16, 0.61), 0.17 (range: 0.13, 0.32) and 0.13 (range: 0.05, 0.23), respectively (p = 0.004). The corresponding mean ADCs (×10–3 mm2/s) for low‐grade, intermediate‐grade and high‐grade cancer were 0.99 ± 0.08, 0.86 ± 0.11 and 0.69 ± 0.12, respectively (p < 0.0001). The combined ADC and metabolite ratio model showed strong discriminatory ability to differentiate subjects with GS ≤ 6 from subjects with GS ≥ 7 with an area under the curve of 94%. These data indicate that pre‐biopsy mpMRI may stratify PCa aggressiveness noninvasively. As the recent literature data suggest that men with GS ≤ 6 cancer may not need radical therapy, our data may help limit the need for biopsy and allow informed decision making for clinical intervention. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

16.
The aim of this study was to assess the feasibility of combining dynamic contrast enhanced‐magnetic resonance imaging (DCE‐MRI) with the measurement of the radiofrequency (RF) transmit field B 1 and pre‐contrast longitudinal relaxation time T 10. A novel approach has been proposed to simultaneously estimate B 1 and T 10 from a modified DCE‐MRI scan that actively encodes the washout phase of the curve with different amounts of T 1 and B 1 weighting using multiple flip angles and repetition times, hence referred to as active contrast encoding (ACE)‐MRI. ACE‐MRI aims to simultaneously measure B 1 and T 10, together with contrast kinetic parameters, such as the transfer constant K trans, interstitial space volume fraction v e and vascular space volume fraction v p. The proposed method was tested using numerical simulations and in vivo studies with mouse models of breast cancer implanted in the flank and mammary fat pad, and glioma in the brain. In the numerical simulation study with a signal‐to‐noise ratio of 10, both B 1 and T 10 were estimated accurately with errors of 5.1 ± 3.5% and 12.3 ± 8.8% and coefficients of variation (CV) of 14.9 ± 8.6% and 15.0 ± 5.0%, respectively. Using the same ACE‐MRI data, the kinetic parameters K trans, v e and v p were also estimated with errors of 14.2 ± 8.3% (CV = 13.5 ± 4.6%), 14.7 ± 9.9% (CV = 13.3 ± 4.5%) and 14.0 ± 9.3% (CV = 14.0 ± 4.5%), respectively. For the in vivo tumor data from 11 mice, voxel‐wise comparisons between ACE‐MRI and DCE‐MRI methods showed that the mean differences for the five parameters were as follows: ΔK trans = 0.006 (/min), Δv e = 0.016, Δv p = 0.000, ΔB 1 = ?0.014 and ΔT 1 = ?0.085 (s), which suggests a good agreement between the two methods. When compared with separately measured B 1 and T 10, and DCE‐MRI estimated kinetic parameters as a reference, the mean relative errors of ACE‐MRI estimation were B 1 = ?0.3%, T 10 = ?8.5%, K trans = 11.4%, v e = 14.5% and v p = 4.5%. This proof‐of‐concept study demonstrates that the proposed ACE‐MRI method can be used to estimate B 1 and T 10, together with contrast kinetic model parameters.  相似文献   

17.
The vertebrate mid‐hindbrain boundary (MHB) is a crucial morphological structure required for patterning and neural differentiation of the midbrain and anterior hindbrain. We isolated a novel zebrafish mutant, MHB gone (mgo), that exhibited a defective MHB. Expression of engrailed3 in the prospective MHB was absent at the 1‐somite stage, suggesting that initiation of the isthmic organizer was disrupted in mgo mutants. Complementation test with mgo and noi, in which the pax2a gene is mutated, infer that the mgo mutant may represent a novel noi allele. However, pronephric, otic vesicle, and commissural axonal defects described in noi mutants were not associated with mgo mutants. Genetic mapping revealed that the mgo mutation is linked to the Pax2a locus, but no mutation was detected in pax2a exons or within intron‐exon boundaries. Based on these findings, we propose that the mgo mutation genetically interacts with pax2a required for the initiation of MHB formation. Developmental Dynamics 238:899–907, 2009. © 2009 Wiley‐Liss, Inc.  相似文献   

18.
Manganese‐enhanced MRI studies have proven to be useful in monitoring physiological activities associated with calcium ions (Ca2+) due to the paramagnetic property of the manganese ion (Mn2+), which makes it an excellent probe of Ca2+. In this study, we developed a method in which a Mn2+‐enhanced T1‐map MRI could enable the monitoring of Ca2+ influx during the early stages of intestinal ischemia–reperfusion (I/R) injury. The Mn2+ infusion protocol was optimized by obtaining dose‐dependent and time‐course wash‐out curves using a Mn2+‐enhanced T1‐map MRI of rabbit abdomens following an intravenous infusion of 50 mmol/l MnCl2 (5–10 nmol/g body weight (BW)). In the rabbit model of intestinal I/R injury, T1 values were derived from the T1 maps in the intestinal wall region and revealed a relationship between the dose of the infused MnCl2 and the intestinal wall relaxation time. Significant Mn2+ clearance was also observed over time in control animals after the infusion of Mn2+ at a dose of 10 nmol/g BW. This technique was also shown to be sensitive enough to monitor variations in calcium ion homeostasis in vivo after small intestinal I/R injury. The T1 values of the intestinal I/R group were significantly lower (P < 0.05) than that of the control group at 5, 10, and 15 min after Mn2+ infusion. Our data suggest that MnCl2 has the potential to be an MRI contrast agent that can be effectively used to monitor changes in intracellular Ca2+ homeostasis during the early stages of intestinal I/R injury. Copyright © 2015 John Wiley & Sons, Ltd.  相似文献   

19.
The structure and development of the brain are extremely difficult to study in free‐ranging marine mammals. Here, we report measurements of total white matter (WM), total gray matter (GM), cerebellum (WM and GM), hippocampus, and corpus callosum made from magnetic resonance (MR) images of fresh, postmortem brains of the Atlantic white‐sided dolphin (Lagenorhynchus acutus) imaged in situ (i.e., the brain intact within the skull, with the head still attached to the body). WM:GM volume ratios of the entire brain increased from fetus to adult, illustrating the increase in myelination during ontogeny. The cerebellum (WM and GM combined) of subadult and adult dolphins ranged from 13.8 to 15.0% of total brain size, much larger than that of primates. The corpus callosum mid‐sagittal area to brain mass ratios (CCA/BM) ranged from 0.088 to 0.137, smaller than in most mammals. Dolphin hippocampal volumes were smaller than those of carnivores, ungulates, and humans, consistent with previous qualitative results assessed from histological studies of the bottlenose dolphin brain. These quantitative measurements of white matter, gray matter, corpus callosum, and hippocampus are the first to be determined from MR images for any cetacean species. We establish here an approach for accurately determining the size of brain structures from in situ MR images of stranded, dead dolphins. This approach can be used not only for comparative and developmental studies of marine mammal brains but also for investigation of the potential impacts of natural and anthropogenic chemicals on neurodevelopment and neuroanatomy in exposed marine mammal populations. Anat Rec, 291:263–282, 2008. © 2008 Wiley‐Liss, Inc.  相似文献   

20.
We have designed and constructed an experimental set‐up allowing electrical stimulation of hindlimb mouse muscles and the corresponding force measurements at high‐field (11.75T). We performed high‐resolution multimodal MRI (including T2‐weighted imaging, angiography and diffusion) and analysed the corresponding MRI changes in response to a stimulation protocol. Mice were tested twice over a 1‐week period to investigate the reliability of mechanical measurements and T2 changes associated with the stimulation protocol. Additionally, angiographic images were obtained before and immediately after the stimulation protocol. Finally, multislice diffusion imaging was performed before, during and immediately after the stimulation session. Apparent diffusion coefficient (ADC) maps were calculated on the basis of diffusion weighted images (DWI). Both force production and T2 values were highly reproducible as illustrated by the low coefficient of variation (<8%) and high intraclass correlation coefficient (≥0.75) values. Maximum intensity projection angiographic images clearly showed a strong vascular effect resulting from the stimulation protocol. Although a motion sensitive imaging sequence was used (echo planar imaging) and in spite of the strong muscle contractions, motion artifacts were minimal for DWI recorded under exercising conditions, thereby underlining the robustness of the measurements. Mean ADC values increased under exercising conditions and were higher during the recovery period as compared with the corresponding control values. The proposed experimental approach demonstrates accurate high‐field multimodal MRI muscle investigations at a preclinical level which is of interest for monitoring the severity and/or the progression of neuromuscular diseases but also for assessing the efficacy of potential therapeutic interventions. Copyright © 2014 John Wiley & Sons, Ltd.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号