首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 218 毫秒
1.
目的:探讨对经胸超声心动图(TTE)指导房间隔缺损(ASD)封堵术的作用。方法:30例继发孔型ASD患者术前均采用彩色多普勒TTE加自然组织谐波功能经胸测量各切面ASD大小,监测封堵过程、封堵器的牢固性及彩色多普勒观察有无残余分流。封堵器释放后测量其腰部大小并与术前测ASD最大径比较。结果:用TTE术前检查ASD最大径为7mm~30mm(平均18.5mm),选用封堵器10mm~38mm(平均24mm),释放后封堵器腰径7mm~30mm(平均18.5mm)。TTE测量ASD大小与封堵器大小相关良好。除1例封堵器移位改为经胸手术外,其余患者封堵器固定牢固、无脱落。结论:TTE可以较准确测量ASD大小,是指导ASD封堵的行之有效的方法。  相似文献   

2.
目的:评价经胸超声心动图(TTE)与经食管超声心动图(TEE)在继发孔型房间隔缺损(ASD)介入封堵术中的应用价值。方法:对52例继发孔型ASD患者术前均行TTE或TEE检查,根据检查结果选择封堵器型号,术中应用TTE或TEE引导监测封堵器的释放。根据引导方式,分为A组30例,使用TTE引导监测;B组22例,使用TEE引导监测。术后使用TTE随访。结果:A组29例在TTE引导下介入封堵治疗成功,1例因下腔静脉缘较薄未封堵成功,成功率96.67%;B组21例在TEE引导下介入封堵治疗成功,1例因ASD过大未封堵成功,成功率95.45%。A组TTE术前检查ASD直径3~27mm,实际用封堵器大小8~36mm,B组TEE术前检查ASD直径4~36mm,实际用封堵器大小8~40mm,A组ASD直径小于B组,两组差异无统计学意义(P0.05);A组封堵器大小小于B组,两组差异无统计学意义(P0.05);两组ASD直径与封堵器大小间相关性均较好。50例随访3~6个月以上,效果良好,均无并发症。结论:依靠TTE或TEE选择封堵器、术中引导监测ASD介入封堵治疗可以顺利完成。TTE及TEE是引导ASD介入封堵治疗必不可少的手段。  相似文献   

3.
目的评价经胸超声心动图(TTE)术前测量房间隔缺损(ASD)大小,估测肺动脉高压(PH)及术中监测ASD封堵的作用。方法5例ASD并发PH患者术前用彩色多普勒超声诊断仪经胸测量各切面ASD大小和周缘情况,并根据三尖瓣反流压差估测肺动脉收缩压,经心导管ASD封堵术中TTE监测封堵过程、伞释出后牢固程度及彩色多普勒有无分流,ASD并发PH重度患者试封堵30分钟,超声监测效果。结果用TTE术前检查ASD大小25~34(28.2±3.78)mm,选用的封堵器大小为30~38(34.0±3.29)mm。硬缘ASD的封堵器选择比超声所测ASD大4~6mm。所有封堵器封堵牢固,无脱落。结论TTE术前检查及术中指导ASD并发PH患者封堵是一种可行、有效、简便的方法。  相似文献   

4.
目的:评价经胸超声心动图(TTE)指导经胸微创房间隔缺损(ASD)封堵术的可行性及作用。方法:32例ASD病人,年龄3~59岁,平均20±15.6岁,术前用GE VIVI7D彩色多普勒超声诊断仪经胸测量ASD的大小及周缘。ASD封堵术中监测封堵整个过程,封堵器的牢固性,观察有无残余分流。结果:术前用TTE测量的ASD最大径4~32mm,平均16.7±6.3mm,选用的封堵器是8~40mm,平均24.48±7.3mm,TTE测量的ASD大小与封堵器大小相关良好(r=0.94,P〈0.001)。所有ASD病人封堵器固定牢固,无脱落。结论:TTE可准确测量ASD的大小,是指导ASD封堵的可行、有效、简便的方法。  相似文献   

5.
目的 探讨经胸超声心动图(transthoracic eChocardiography,TTE)在封堵房间隔缺损(atrial septal defect,ASD)围手术期中的应用价值.方法 选择试验对象,应用TTE测量60例患者房间隔缺损大小,在TTE的检测下对ASD行经导管封堵,评价TTE在封堵ASD围手术期中的应用价值.结果 TTE成功引导57例患者封堵器置入,术中及术后均无并发症,无残余分流,总的成功率为95%(57/60).结论 TTE对于应用封堵器封堵ASD术前病例选择、指导选择封堵器型号、导管通道建立以及放置封堵器的全过程和术后疗效评价起着重要作用.  相似文献   

6.
目的研究经胸超声心动图(TTE)在指导Amplatzer封堵器封堵动脉导管未闭(PDA)、房间隔缺损(ASD)及室间隔缺损(VSD)中的应用价值。方法4例PDA、7例ASD及1例VSD经TTE引导行经导管Amplatzer封堵器封堵。结果12例患者9例封堵成功,其中PDA4例、ASD5例,2例ASD及1例VSD封堵失败,封堵成功率75%。成功者术后无残余分流。结论TTE在引导Amplatzer封堵器封堵PDA、ASD及VSD的术前病例选择、术中监测、封堵器型号选择与术后疗效评价方面有着重要作用。  相似文献   

7.
目的 评价超声心动图在术前病例选择,术中监测及术后随访的价值.方法 28例继发孔型房间隔缺损(ASD)患者术前行经胸超声心动图(TTE)检查,确定适合封堵术,并进一步术中监测和术后随访.结果 房间隔缺损封堵术后3d和1mo、3mo,封堵器的位置和形态正常,无残余分流,无严重并发症发生,封堵术成功率为100%.结论 TTE对应用Amplatzer封堵器,封堵ASD的术前病例选择,指导选择封堵器型号,术中监测及术后观察有无残余分流,评价疗效有着重要的价值.  相似文献   

8.
目的探讨经胸超声心动图(TTE)在继发孔型房闻隔缺损(ASD)封堵前术中的应用价值。方法应用TTE指导24例继发孔型ASD患者行经导管封堵术。结果24例患者全部成功封堵,无残余分流。结论TTE对AS/)封堵的术前病例选择,指导选择封堵器型号,术中监测封堵器置放及释放过程,术后观察封堵器位置是否合适、稳定,有无残余分流,是否影响周围结构和功能等,均具有重要的应用价值。  相似文献   

9.
超声心动图在微创外科房间隔缺损封堵治疗中的应用   总被引:1,自引:0,他引:1  
康彧  唐红  宋海波  白文娟  安琪  赁可  张尔永 《西部医学》2009,21(9):1585-1586,1589
目的探讨超声心动图在微创外科房间隔缺损(ASD)封堵治疗中的应用价值。方法术前经胸超声心动图(TTE)筛选单纯继发孔中央型ASD95例,术中经食管超声心动图(TEE)进一步评估引导微创外科封堵治疗,术后3~6月TTE随访。结果95倒患者行ASD微创外科封堵术,封堵成功86例,占90.5%,9例封堵失败。TEE与TTE对ASD最大径及残缘测量值差异无统计学意义(P〉O.05)。房间隔伸展径TTE测量值大于TEE(P〈0.01)。TTE对上、下腔静脉缘的显示率为71.6%和77.8%,低于TEE(P〈0.01)。术后3~6个月1vrE随访,封堵器位置稳定,无移位,未影响周围瓣膜功能及静脉回流,1例有微量残余分流。右心重构改善,右房、右室内径较术前缩小,肺动脉血流速度降低(P〈0.01)。结论超声心动图贯穿了微创外科ASD封堵治疗的全程,TEE与TTE联合应用,对术前诊断与筛选、术中选择封堵器和实时监控、术后效果评价发挥了重要作用。  相似文献   

10.
目的:探讨多平面经食管超声心动图(MTEE)在Amplatzer封堵器治疗房间隔缺损(ASD)中的应用价值。方法:应用MTEE进行封堵术前选择病例、术中监测以及术后疗效评价,并用经胸超声心动图(TTE)随访。结果:经MTEE检查发现,符合封堵条件的2例ASD患者,在MTEE及X线的引导下,顺利输送、释放封堵器,彩色多普勒血流显像(CDFI)检测提示无残余分流,封堵成功。术后3天、6个月及12个月行TTE检查,均显示封堵器位置准确、固定,无残余分流。结论:MTEE在Amplatzer封堵器治疗术前ASD病例的选择、术中引导封堵器置入、术后疗效评价及随访观察等方面有重要作用.  相似文献   

11.
Previously,thesingletreatmentmethodforsecundumtypeatrialseptaldefect (ASD )wassurgery Asanalternativetosurgery,severalattemptshavebeenmadetoclosesecundumatrialseptaldefectsbyatranscathetertechnique 1 11 Duetoimproveddesignandexperience,however,onlongtermfol…  相似文献   

12.
经导管置入Amplatzer封堵器治疗继发孔型房间隔缺损(ASD),评价其初步疗效。方法5例患者术前经胸超声心动图检查示ASD平均直径14.2mm(7~17mm),经食管超声心动图(TEE)检查示ASD平均直径13.4mm(6~17mm),术中用球囊测量ASD伸展径平均17.5mm(7.7~24mm)。患者均在透视及TEE监视下经导管置入Amplatzer封堵器封堵ASD。术后即刻、1天、1、3、6、12个月分别行超声心动图、心电图检查,评价疗效。结果5例封堵器置入均获成功。1例术后随访6个月、3例随访12个月,均无残余分流、血栓栓塞;右室直径由术前的平均32.6mm减少到术后1个月的28.5mm、6个月的24.7mm、12个月的24.5mm。结论经导管置入Amplatzer封堵器治疗继发孔房间隔缺损是操作简便、患者创伤小、安全、有效的方法。  相似文献   

13.
目的 :探讨多平面经食管超声心动图 (MTEE)在Amplatzer封堵器封堵继发孔型房间隔缺损 (ASD)中的应用价值。方法 :应用MTEE筛选符合封堵条件的 2 4例ASD患者行导管封堵术。在超声和X线引导下 ,以ASD伸展径加 0~ 4mm为标准 ,选择相应型号的封堵器 ,导管送封堵器至缺损处 ,依次释放左房面伞、腰部及右房面伞 ,观察位置合适时撤出导管 ,完成手术。结果 :2 4例患者均成功的进行了封堵 ,所有患者术中及术后均无并发症 ,术后即刻无残余分流。MTEE测量的ASD最大直径显著小于ASD伸展径 [〔 2 0 .2± 5 .6 )mmvs (2 4 .5± 5 .4 )mm ,P <0 .0 1\〗 ,平均相差 4mm。所有患者术后 2 4h、1个月及 3个月经胸超声检查均无残余分流及其它并发症。结论 :MTEE指导Amplatzer封堵器导管介入治疗继发孔型ASD是一种安全、有效的监测方法 ,其在病例选择、选择封堵器型号及放置封堵器过程中起重要的作用。  相似文献   

14.
Background In China, transthoracic echocardiography (TTE) is popularly used for pre-intervention examination for atrial septal defect (ASD) and for guiding ASD closure. However, the ability to determine ASD size and the safety and efficacy of l-rE for guiding ASD closure still has not been widely accepted. This study aimed to evaluate the efficacy and safety of l-rE used before, during and after transcatheter ASD closure with Amplatzer septal occluders (ASO).
Methods Sixty-eight subjects (15 men and 53 women; mean age (33.7±17.3) years) were enrolled. TTE was used to measure the diameters and guide transcatheter closure of ASD. The ASD was examined by long-axis view, basal short-axis view, apical four-chamber view and the subcostal view to observe position, diameter and relation with neighbouring structures. The largest diameter was selected as the reference diameter. Patients were divided into 3 groups according to the ASD reference diameter: 22 subjects with ASD diameter 4-14 mm (group A); 21 subjects with ASD diameter 15-20 mm (group B); and 25 subjects with ASD diameter 21-33 mm (group C).
Results ASD was occluded successfully in groups A and B. In group C, occlusion failed in 2 cases; 1 case remained with a 3-mm residual shunt sustained until 6-month follow-up. However, at 6-month follow-up, no case of thromboembolism, ASO dislocation or death occurred in the three groups. The diameter of ASD measured by l-rE could accurately predict the ASO size that could successfully occlude the ASD, especially in patients with ASD 〈20 mm. The ASD diameter measured by l-rE correlated well with ASO size (r= 0.925, P〈0.001 ; r=0.976, P〈0.001 ; r=0.929, P〈0.001 respectively).
Conclusions ASD diameter measured by l-rE can accurately estimate the size of the ASO needed for successful closure of ASD. The larger the ASD, the much larger the ASO needed. l-rE is a satisfactory guiding imaging tool for ASD closure.  相似文献   

15.
目的:评价超声心动图引导下采用国产器材在封堵房间隔缺损(atrial septal defect,ASD)时心导管法及经胸 小切口法两种介入术式的安全性。方法:回顾性分析成功采用国产器材封堵ASD共1 080例,其中心导管法734例,经 胸小切口法346例。心导管法术中是在导管室用大型数字减影血管造影机引导下,并结合经胸超声心动图(transthoracic echocardiography,TTE)监测整个封堵过程,以TTE评价疗效。经胸小切口法在手术室完全使用经食管超声心动图 (transesophageal echocardiography,TEE)引导整个封堵过程,指导放置封堵器,并即刻评价疗效。结果:两种介入术式 中用国产器材封堵ASD均能取得满意疗效,两种介入术式比较,缺损最长径大小差异无统计学意义(P>0.05),ASD/房 间隔长度、封堵器大小、封堵器大小与ASD最长径的差值差异均有统计学意义(均P<0.05)。当ASD算术平均数<30 mm 时,两种介入术式封堵成功率均为100%;当ASD算术平均数≥30 mm时,经胸小切口法封堵成功率为100%,心导管法 封堵成功率为50%。结论:国产器材封堵安全,成本低。对于同样大小的缺损,经胸小切口法选择的封堵器较小,更 合适。当ASD算术平均数≥30 mm时,经胸小切口法成功率比心导管法大,心导管法失败者可转为经胸小切口法。  相似文献   

16.
目的:旨在评价经食管超声心动图(TEE)在行Amplatzer间隔封堵器(ASO)经导管修补继发孔型房间隔缺损术中的应用价值。方法:选择继发孔型房间隔缺损患者62例,年龄10~55岁。超声检查用于①术前筛选;②术中采用经食管超声心动图进行封堵术中引导和监测;③术后复查,观察封堵器的位置、周围结构的关系、有无残余分流等。结果:本组患者采用TTE、TEE和球囊X线影像(房间隔缺损最大伸展径)3种测量方法。其结果显示:TTE测值(19.1±5.8)mm与术中球囊测值(25.1±6.4)mm之间存在显著性统计学差异(P<0.001);TEE测值(23.5±6.2)mm与术中球囊测值之间不存在统计学差异(P>0.05)。62例患者均在TEE引导和监测下成功地完成ASD封堵。CDFI显示其中61例,封堵器释放后即无左向右分流;1例上腔静脉型ASD患者,靠上腔静脉端有2mm残余分流。术后即刻、24h、1个月、3个月、6个月、1年行TTE或TEE检查,62例患者封堵器位置稳定、无移位,未影响周围瓣膜的功能及静脉的回流。1例上腔静脉型ASD患者,1年后靠上腔静脉端仍有2mm的残余分流;余61例无左向右分流。结论:在经导管Amplatzer间隔封堵器修补ASD术中,TEE可准确地引导和监测封堵器的放置,评估手术疗效。同时,TEE在ASD封堵术中的应用是安全、可行、患者完全可以耐受的。  相似文献   

17.
微创房间隔缺损封堵术8例临床研究   总被引:7,自引:0,他引:7  
目的:总结微创房间隔缺损封堵术治疗先天性心脏病继发孔型房间隔缺损的初步经验。方法:全组8例,年龄6-59岁,手术前经食管超声心动图(TEE)检查先天性心脏病房间隔缺损(ASD)直径平均为17-35mm,所有病例均在TEE指引下经输送器置入封堵伞,1例ASD为双孔型,置入2个封堵伞,术后分别采用经胸超声心动图(TTE),心电图,X线评价治疗效果。结果:8例手术均获得成功,术中未发生任何并发症,经4-7个月随访,TTE示无残余漏发生,X线检查全部显示肺血减少,右心房,室缩小,结论:微创房间隔缺损封堵术治疗ASD具有安全,高效,微创的优点,适合各年龄组继发孔型ASD,其临床应用的中远期疗效和手术适应证有待继续观察。  相似文献   

18.
目的 评价国产封堵器经导管介入封堵治疗儿童先天性心脏病的临床经验。 方法 选取2014年1月—2016年7月104例无锡儿童医院住院适合用介入方法封堵治疗的儿童先天性心脏病患者,男49例,女55例,年龄10个月5天~15岁,平均年龄(3.8±2.9)岁;体重8.5~68.0 kg,平均(16.25±9.3) kg。其中继发孔型房间隔缺损(ASD)54例,动脉导管未闭(PDA)21例,膜周部室间隔缺损(PVSD)26例,肌部室间隔缺损(MVSD)1例,膜周部室间隔缺损合并房间隔缺损1例,房间隔缺损合并动脉导管1例,均行国产封堵器介入治疗。房间隔缺损及室间隔缺损患儿术后口服阿司匹林3~5 mg/(kg·d)(最大量100 mg/d),疗程6个月。同时术后24 h复查胸片、心电图、心脏彩超,室间隔缺损封堵术后行24 h动态心电图检查。术后第1、3、6、12个月予心脏超声、心电图追踪及随访,以后每年常规复查心电图、心脏彩超。 结果 共植入国产封堵器106个,同时植入2个封堵器患儿4例。介入封堵成功102例,2例封堵失败,封堵成功率为98.08%。严重并发症发生率为0.96%,其他并发症17例。所有患者均无心包填塞,无封堵器移位,无溶血,无血栓或气栓形成。 结论 国产封堵器经导管介入封堵治疗儿童先天性心脏病临床疗效肯定,严重并发症发生率低,是一种安全、有效的治疗方法。但在治疗过程中应严格把握介入治疗的适应证及禁忌证,术后坚持长期随访心电图及心脏超声。   相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号