1.
The purpose of this study was to assess the efficacy of a new perfused-cooled electrode that uses a single pump for creating a large ablation zone in explanted bovine liver. This was done by comparing with the radiofrequency (RF) ablation zones that were created with a monopolar cooled electrode to the RF ablation zones that were created by the new perfused-cooled electrode. We developed a new perfused-cooled electrode that uses a single pump by modifying a 17-gauge cooled electrode (Radionics) with a 2.5-cm outer metallic sheath (15-gauge) in order to allow use of the internal cooling water (5.85 % hypertonic saline) for the infused saline. Thirty ablation zones were created in explanted bovine livers (12-min ablation cycle; pulsed technique; 2000 mA, maximum) with three different regimens: group A, RF ablation with the 17-gauge cooled electrode; group B, RF ablation with the 15-gauge cooled electrode; group C, RF ablation with the perfused-cooled electrode. T2-weighted magnetic resonance (MR) imaging was obtained immediately after RF ablation for calculating volumes of the ablation zone. Following MR imaging, the ablation zones were excised and measured for transverse diameters and vertical diameters. The transverse diameter, vertical diameter, and the calculated volumes of the ablation zones on MR imaging were compared among the groups. Ablation zones created with the perfused-cooled electrode (group C) were significantly larger than those created with the 17-gauge cooled electrode (group A) and the 15-gauge cooled electrode (group B) according to the transverse diameter and vertical diameter on the gross specimens (p < 0.05): 3.6 ± 0.38 cm and 4.4 ± 0.20 cm in group A, 3.7 ± 0.08 cm and 4.6 ± 0.16 cm in group B, and 5.4 ± 0.65 cm and 6.0 ± 0.56 cm in group C, respectively. On the MR imaging, the calculated volumes of the ablation zones in group C were significantly larger than those in groups A and B (p < 0.05): 23.1 ± 8.7 cm3 in group A, 28.9 ± 5.7 cm3 in group B, and 80.0 ± 34 cm3 in group C, respectively. A new perfused-cooled electrode using a single pump could efficiently increase the size of the ablation zone in liver compared with a monopolar cooled electrode, and this was due to its simultaneous use of internal cooling and saline infusion.  相似文献   

2.
RATIONALE AND OBJECTIVES: A cooled-wet electrode has been developed for radiofrequency ablation (RFA) that allows simultaneous internal-cooling perfusion ("cooled") and interstitial hypertonic saline infusion ("wet"). The present comparative study was conducted to validate this new device for the increased coagulation volume in RFA. METHODS: Under low-power (50 W, groups A through F) and high-power (90 W, groups A' through F') control modes, 240 RFA lesions were created on excised beef liver to compare the cooled-wet electrode with other monopolar electrodes. The experimental regimens were as follows: groups A and A', conventional RF electrode; groups B and B', cooled electrode; groups C and C', wet electrode; groups D and D', cooled-wet electrode; groups E and E', cooled-wet electrode but suspended wet function; and groups F and F', cooled-wet electrode but suspended cooled function. The ablation efficacy was evaluated by comparing the lesion sizes as well as parameters of impedance, power output, current, and tip temperature. RESULTS: With lower impedance and tip temperature but higher power output, the lesion size in groups D (4.90 +/- 0.60 cm) and D' (6.6 +./- 0.99 cm) was significantly larger than that in other groups. CONCLUSIONS: The use of the cooled-wet electrode could efficiently increase the lesion size for liver ablation.  相似文献   

3.
Purpose To develop a flow model for bovine livers for extensive bench testing of technical improvements or procedure-related developments of radiofrequency ablation excluding animal experiments. Methods The perfusion of bovine livers directly from the slaughterhouse was simulated in a liver perfusion tank developed for the experimental work. The liver perfusion medium used was a Tyrode solution prepared in accordance with physiologic criteria (as for liver transplants) which was oxygenated by an oxygenator and heated to 36.5°C. Portal vein circulation was regulated via a flow- and pressure-controlled pump and arterial circulation using a dialysis machine. Flow rate and pressure were adjusted as for the physiology of a human liver converted to bovine liver conditions. The fluid discharged from the liver was returned into the perfusion system through the vena cava. Extendable precision swivel arms with the radiofrequency probe attached were mounted on the liver perfusion tank. RFA was conducted with the RF3000 generator and a 2 cm LeVeen needle (Boston Scientific, Ratingen, Germany) in a three-dimensional grid for precise localization of the generated thermolesions. Results Four bovine livers weighing 8.4 ± 0.4 kg each were prepared, connected to the perfusion system, and consecutively perfused for the experiments. Mean arterial flow was 569 ± 43 ml/min, arterial pressure 120 mmHg, portovenous flow 1440 ± 305 ml/min, and portal pressure 10 mmHg. Macroscopic evaluation after the experiments revealed no thrombi within the hepatic vessels. A total of 136 RF thermolesions were generated with an average number of 34 per liver. Mean RF duration was 2:59 ± 2:01 min:sec with an average baseline impedance of 28.2 ± 3.4 ohms. The mean diameter of the thermolesions along the puncture channel was 22.98 ± 4.34 mm and perpendicular to the channel was 23.27 ± 4.82 mm. Conclusion Extracorporeal perfusion of bovine livers with consecutive standardized RF ablation was feasible. The bovine liver flow model seems to allow extensive, standardized evaluation of technical or procedure-related developments of RF systems.  相似文献   

4.
RATIONALE AND OBJECTIVES: A major limitation of radiofrequency (RF) ablation is its inability to produce a large enough diameter of coagulation necrosis to encompass hepatic tumors with an appropriate ablative margin at a single RF application. We evaluated the in vivo efficiency of RF ablation (RFA) using an internally cooled perfusion (ICP) electrode with hypertonic saline infusion to induce coagulation necrosis compared with that of RFA using single needle electrode types. MATERIALS AND METHODS: RF was applied to a porcine liver in monopolar mode using a 200 W generator and an internally cooled electrode (group A) or an ICP electrode (group B) at 200 W for 12 minutes or using a 60 W generator with a perfusion electrode at 40 W for 20 minutes (group C). In total, 36 (3 x 12) ablation zones were created using the three different regimens. In group B, 14.6% NaCl solution was infused at 1 mL/minute and in group C, 0.9% NaCl solution was infused at 1.5 mL/minute. The three groups were compared in terms of amount of delivered RF energy and dimensions and the coefficients of variation of the ablation zones. RESULTS: The mean energies applied in the three groups were 52.3 +/- 10.3 kJ for group A, 115.4 +/- 10.5 kJ for group B, and 38.5 +/- 11.5 kJ for group C, respectively (P < .05). The mean ablation volumes in groups A, B and C were 13.1 +/- 4.7 cm3 in group A, 43.7 +/- 17.5 cm3 in group B, and 26.3 +/- 20.2 cm3 in group C, respectively (P < .05). In addition, the coefficients of variation of the volumes of the ablation zones in groups A, B, and C were 0.36, 0.4, and 0.78, respectively. CONCLUSIONS: RFA using the ICP electrode showed better performance in terms of creating a larger ablation zone than RFA using an internally cooled or a perfusion electrode.  相似文献   

5.
OBJECTIVE: To compare two different expandable electrodes in radiofrequency ablation of renal cell carcinoma. METHODS: Percutaneous ablation was performed at two centers using either an expandable 7F umbrella-shaped LeVeen probe (diameter 2-4 cm) and a 200-W generator (group A), or an expandable Starburst XL electrode with a 150-W generator (group B). From each center, eight patients with one tumor each were matched retrospectively with regard to tumor volume, which was 9.71+/-6.43 cm3 for group A and 8.74+/-4.35 cm3 for group B (mean tumor diameter: 2.47+/-0.9 cm versus 2.50+/-0.4 cm, respectively). An unpaired t-test showed no significant difference in tumor volume between the two groups (p=0.820). RESULTS: Sixteen patients with 16 tumors were treated. The primary technical success of radiofrequency ablation was 94% (15 of 16 patients). After retreatment of residual tumor in one patient from group B, secondary technical success was 100%. No major complications were observed. The resulting mean volume of the almost spherical necroses was 21.1+/-9.1 cm3 versus 14.6+/-6.7 cm3 for groups A and B (diameter of necrosis: 3.5+/-0.7 cm versus 3.1+/-0.6 cm, respectively). A Mann-Whitney U-test showed no significant difference in necrosis volume between the two groups (CI [-0.215; 0.471]; p=0.2892). The calculated shape value of S (ratio of length to height of the coagulation necrosis) was 0.9+/-0.1 and 1.0+/-0.1 for groups A and B, respectively. No local recurrence was observed during a mean follow-up of 14.8+/-11.6 months, while extrarenal tumor progression occurred in three patients. CONCLUSIONS: No significant differences in coagulation volume and shape were found after RF ablation of renal cell carcinoma using two different expandable electrodes. To avoid local recurrence, however, accurate placement of probes and appropriate expansion of the electrode is necessary.  相似文献   

6.
Purpose To evaluate the influence of continuous infusion of acetic acid 50% during radiofrequency ablation (RFA) on the size of the thermal lesion produced. Methods Radiofrequency (RF) was applied to excised bovine liver by using an expandable needle electrode with 10 retractable tines (LeVeen Needle Electrode, RadioTherapeutics, Sunnyvale, CA) connected to a commercially available RF generator (RF 2000, RadioTherapeutics, Sunnyvale, CA). Experiments were performed using three different treatment modalities: RF only (n = 15), RF with continuous saline 0.9% infusion (n = 15), and RF with continuous acetic acid 50% infusion (n = 15). RF duration, power output, tissue impedance, and time to a rapid rise in impedance were recorded. The ablated lesions were evaluated both macroscopically and histologically. Results The ablated lesions appeared as spherical or ellipsoid, well-demarcated pale areas with a surrounding brown rim with both RF only and RF plus saline 0.9% infusion. In contrast, thermolesions generated with RF in combination with acetic acid 50% infusion were irregular in shape and the central portion was jelly-like. Mean diameter of the coagulation necrosis was 22.3 ± 2.1 mm (RF only), 29.2 ± 4.8 mm (RF + saline 0.9%) and 30.7 ± 5.7 mm (RF + acetic acid 50%), with a significant increase in the RF plus saline 0.9% and RF plus acetic acid 50% groups compared with RF alone. Time to a rapid rise in impedance was significantly prolonged in the RF plus saline 0.9% and RF plus acetic acid 50% groups compared with RF alone. Conclusions A combination of RF plus acetic acid 50% infusion is able to generate larger thermolesions than RF only or RF combined with saline 0.9% infusion.  相似文献   

7.
PURPOSE: To compare in vivo efficacy of multipolar radiofrequency (RF) ablation with two internally cooled electrodes to that of monopolar RF ablation with internally cooled single and cluster needles to induce coagulation in in vivo porcine kidneys. MATERIALS AND METHODS: Twenty-four coagulations were created in the kidneys of 12 pigs by means of laparotomy by using a monopolar or multipolar RF system. In the monopolar mode, RF was applied to a single internally cooled probe (group A) or to a cluster probe (group B) for 12 minutes. In the multipolar mode, RF was applied to two bipolar probes with 2-cm interprobe spacing up to 50 kJ (group C). Technical parameters and the dimensions, shapes, and coefficients of variation of the coagulations were compared among the three groups. RESULTS: The minimum transverse diameters of the RF-induced coagulations in groups B (3.5 cm+/-0.5) and C (3.8 cm+/-0.6) were significantly larger than that in group A (2.6 cm+/-0.3). The mean coagulation volumes produced in the multipolar group (25.1 cm3+/-5.2) were greater than those produced in the monopolar groups (11.6 cm3+/-3.7 and 18.1 cm3+/-5.8) (P<.05). The mean ratio of transverse diameter to vertical diameter of the coagulations was larger in groups B and C (1.2+/-0.2 and 1.0+/-0.1, respectively) than in group A (0.8+/-0.2) (P<.05). In addition, the coefficients of variation for groups A, B, and C were 0.33, 0.30, and 0.21, respectively. The procedure time was longer with the multipolar technique (27.2 minutes+/-4.9) than with the monopolar technique with a single or cluster probe (12 minutes). CONCLUSIONS: Multipolar RF ablation showed at least equivalent or better in vivo efficiency for creating a larger coagulation than monopolar RF ablation with single or cluster electrodes, but with a longer procedure time and at slightly greater complexity.  相似文献   

8.
PurposeVarious radiofrequency (RF) ablation electrode designs have been developed to increase ablation volume. Multiple heating cycles and electrode positions are often required, thereby increasing treatment time. The objective of this study was to evaluate the performance of a high-frequency monopolar induction coil designed to produce large thermal lesions (>3 cm) with a single electrode insertion in a treatment time of less than 10 minutes.Materials and MethodsA monopolar nitinol interstitial coil operated at 27.12 MHz and 200 W was evaluated. Ex vivo performance was tested in excised bovine liver (n=22). In vivo testing (n=10) was conducted in livers of seven Yorkshire pigs. Visual inspection, contrast-enhanced computed tomography (CT), and pathologic evaluation of ablation zones were performed.ResultsAverage ablation volumes in ex vivo and in vivo tests were 60.5 cm3±14.1 (5.9×4.4×4.4 cm) and 57.1 cm3±13.8 (6.1×4.5×4.1 cm), with average treatment times of 9.0 minutes±3.0 and 8.4 minutes±2.7, respectively. Contrast-enhanced CT ablation volume measurements corresponded with findings of gross inspection. Pathologic analysis showed morphologic and enzymatic changes suggestive of tissue death within the ablation zones.ConclusionsThe RF ablation coil device successfully produced large, uniform ablation volumes in ex vivo and in vivo settings in treatment times of less than 10 minutes. Ex vivo and in vivo lesion sizes were not significantly different (P=.53), suggesting that the heating efficiency of this higher-frequency coil device may help to minimize the heat-sink effect of perfusion.  相似文献   

9.
The purpose of this study was to compare the amounts of in vivo coagulation obtained by radiofrequency (RF) ablation in porcine lung, using three types of electrodes. 15 in vivo ablation procedures were performed in the lungs of five pigs using three kinds of currently available RF devices under CT guidance. After placing an electrode in the lung, three ablation zones were created at each of three different regimens: Group A: RF ablation with an internally cooled electrode; Group B: RF ablation with a perfusion electrode, with instillation of 0.9% NaCl solution at a rate of 1.5 ml min(-1); Group C: RF ablation with a multitined expandable electrode. According to the manufacturer's recommendations, RF application times were 12 min in group A and 20 min in group B. In group C, RF energy was delivered for 7 min after a mean temperature of 110 degrees C was reached at 5 cm deployment. 36 min after the procedures, contrast-enhanced CT scans were obtained to evaluate the volume of zone of coagulation, and lungs were harvested for gross measurements. After macroscopic and histopathological analyses of 5 mm-thick lung sections, diameters, volumes and variation coefficients of regions of central coagulation were assessed. During RF ablation, the perfusion electrode allowed a larger energy delivery than the internally cooled or the multitined expandable electrodes, i.e. 33.6+/-4.7 kJ in group A, 40.0+/-8.2 kJ in group B and 23.5+/-6.1 kJ in group C (p<0.05). On gross observation, the cut surface of the gross specimen containing RF-induced coagulation showed that the ablated tissue appeared to be a central, firm, dark-brown area surrounded by an irregular outer margin (approximately 3-10 mm thick) of bright red tissue. In vivo studies showed that RF ablation using the perfusion electrode achieved larger coagulation volume than RF ablation using the other electrodes (p<0.05): 7.2+/-4.1 cm3 in group A; 16.9+/-5.5 cm3 in group B; 7.5+/-3.3 cm3 in group C. The corresponding variation coefficients were 0.55, 0.31, and 0.45, respectively. Our study shows that RF ablation using a perfusion electrode achieves a larger coagulation volume with an irregular margin than RF ablation using internally cooled or multitined expandable electrodes in the porcine lung.  相似文献   

10.
PURPOSE: To determine the extent of hepatic hemorrhage caused by percutaneous cryoablation performed with a small-diameter cryoablation probe compared with that caused by percutaneous radiofrequency (RF) ablation in a porcine model. MATERIALS AND METHODS: The study was pre-approved by the institutional research animal care and use committee, and husbandry and experiments complied with National Institutes of Health standards for care and use of laboratory animals. Percutaneous hepatic ablation was performed in 18 domestic pigs (mean weight, 45 kg) by using a 17-gauge (1.5-mm-diameter) RF electrode (n = 6), a cluster of three RF electrodes (n = 6), or a 13-gauge (2.4 mm-diameter) cryoprobe (n = 6). Ablation was performed in four sites per liver. Total blood loss, minimum lesion diameter, maximum lesion diameter, and lesion volume were determined for each group and compared by using analysis of variance. RESULTS: Mean blood loss was 11.11 mL +/- 11.47 (standard deviation), 105.29 mL +/- 175.58, and 28.06 mL +/- 30.97 with the single RF electrode, RF electrode cluster, and cryoablation probe, respectively. Mean minimum and maximum lesion diameters were largest with the RF electrode cluster (2.40 and 3.98 cm, respectively), followed by the cryoablation probe (2.38 and 3.94 cm) and single RF electrode (1.49 and 2.63 cm). Mean minimum and maximum lesion diameters were significantly different between the single RF electrode and the RF electrode cluster, as well as between the single RF electrode and the cryoablation probe (P < .001). Mean lesion volume was largest for the RF electrode cluster (24.03 cm3), followed by those for the cryoablation probe (17.46 cm3) and single RF electrode (9.05 cm3) (single RF electrode vs cryoablation probe, P < .05). Lesion volumes were not significantly different with the RF electrode cluster versus the single RF electrode (P = .052) or with the RF electrode cluster versus the cryoablation probe (P = .381). CONCLUSION: Mean blood loss from percutaneous cryoablation in this model was between that for RF ablation with the single electrode and that for RF ablation with the electrode cluster.  相似文献   

11.

Objective

To compare the in-vitro efficiency of a hypertonic saline (HS)-enhanced bipolar radiofrequency (RF) system with monopolar RF applications by assessing the temperature profile and dimensions of RF-created coagulation necrosis in bovine liver.

Materials and Methods

A total of 27 ablations were performed in explanted bovine livers. After placement of two 16-gauge open-perfused electrodes at an interelectrode distance of 3 cm, 5% HS was instilled into tissue at a rate of 1 mL/min through the electrode. Seventeen thermal ablation zones were created in the monopolar mode (groups A, B), and ten more were created using the two open-perfused electrodes in the bipolar mode (group C). RF was applied to each electrode for 5 mins (for a total of 10 mins, group A) or 10 mins (for a total of 20 mins, group B) at 50W in the sequential monopolar mode, or to both electrodes for 10 min in the bipolar mode (group C). During RF instillation, we measured tissue temperature at the midpoint between the two electrodes. The dimensions of the thermal ablation zones and changes in impedance and wattage during RFA were compared between the groups.

Results

With open-perfusion electrodes, the mean accumulated energy output value was lower in the bipolar mode (group C: 26675 ± 3047 Watt·s) than in the monopolar mode (group A: 28778 ± 1300 Watt·s) but the difference was not statistically significant (p > 0.05). In the bipolar mode, there were impedance rises of more than 700 Ω during RF energy application, but in the monopolar modes, impedance did not changed markedly. In the bipolar mode, however, the temperature at the mid-point between the two probes was higher (85℃) than in the monopolar modes (65℃, 80℃ for group A, B, respectively) (p < 0.05). In addition, in HS-enhanced bipolar RFA (group C), the shortest diameter at the midpoint between the two electrodes was greater than in either of the monopolar modes: 5.4 ± 5.6 mm (group A); 28.8 ± 8.2 mm (group B); 31.2 ± 7.6 mm (group C) (p < 0.05)

Conclusion

Using an open perfusion system, HS-enhanced bipolar RFA more efficiently created larger areas of thermal ablation and higher tissue temperatures than monopolar RFA.  相似文献   

12.
The purpose of this article is to report our initial experience with the “off-label” use of a new monopolar radiofrequency (RF) probe for percutaneous ablation of osteoid osteomas. Seventeen patients (12 male and 5 female, mean age 24.8 [range 9–49]) with osteoid osteoma were treated by computed tomography (CT)-guided RF ablation (RFA). All procedures were performed with the patient under general aesthesia. After localization of the nidus, a 13G hollow drill was introduced into the nidus through a 7F introducer sheath. A monopolar 16.5G RF probe with a 9-mm active tip (Soloist; Boston Scientific, Natick, MA) was inserted through the introducer sheath and connected to the RF generator. Energy application was started at 2 W and subsequently increased every 2 min by 1 W to a maximum of 8 W. The procedure ended if impedance increased by 500 Ω. Mean duration of energy deposition was 14.2 ± 3.3 min. Fourteen of 17 patients (82%) were free of symptoms at 29.9 ± 14.8 (range 4 to 47) months of follow-up. The primary and secondary success rates were 83% and 100%, respectively. In 3 patients, recurrence of pain at 6 (n = 1) and 15 (n = 2) months after the initial procedure was successfully treated by reablation. There were no complications. Monopolar RFA using the Soloist probe is effective and safe for the treatment of osteoid osteoma. It results in comparable success rates as other monopolar or bipolar RF systems in the treatment of osteoid osteoma.  相似文献   

13.
PURPOSE: The LeVeen radiofrequency (RF) probe uses roll-off of electrical impedance as the endpoint for RF cautery of hepatic tumors. The purpose of this study is to determine the relation of roll-off to local control of hepatic tumors. MATERIALS AND METHODS: Twenty hepatic tumors, including 10 hepatomas and 10 metastases, were treated. Lesions ranged from 1.4 cm to 6.0 cm in diameter; 13 (57%) were smaller than 3.0 cm. Each lesion was ablated with use of the LeVeen 15-gauge RF needle according to the manufacturer's protocol. Five patients underwent chemoembolization the day before. Patients were followed up with contrast-enhanced computed tomography or magnetic resonance imaging at 1 month and every 3 months thereafter. RESULTS: Among the 20 lesions, roll-off was achieved at all burn locations in 11 (55%), no burn locations in eight (40%), and two of three burn locations in one (5%). Roll-off was observed in all patients who had undergone chemoembolization the day before. Six local recurrences occurred, five after RF ablation without roll-off and one after RF ablation with roll-off. According to life-table analysis, the local recurrence rate at 6 months without roll-off was 43% and with roll-off was 15% (P =.024; OR = 8.3; 95% CI = 0.93-66). CONCLUSION: Roll-off is a significant predictor of local control after RF ablation. Strategies to enhance roll-off, such as concurrent embolization, may be important to optimize the therapeutic effect of this device.  相似文献   

14.
OBJECTIVE: To assess the technical feasibility and complications of radiofrequency ablation (RFA) using a monopolar wet electrode for the treatment of inoperable non-small cell lung malignancies. MATERIALS AND METHODS: Sixteen patients with a non-small cell lung malignancy underwent RFA under CT guidance. All the patients were non-surgical candidates, with mean maximum tumor diameters ranging from 3 to 6 cm (mean: 4.6 +/- 1.1 cm). A single 16-gauge open-perfused electrode with a 2 cm exposed tip was used for the procedure. A 0.9% NaCl saline solution was used as the perfusion liquid with the flow adjusted to 30 mL/h. The radiofrequency energy was applied for 10-40 minutes. The response to RFA was evaluated by performing contrast-enhanced CT immediately after RFA, one month after treatment and then every three months thereafter. RESULTS: Technical failure was observed in six (37.5%) of 16 patients: intractable pain (n = 2) and non-stop coughing (n = 4). The mean follow-up interval was 15 +/- 8 months (range: 9-31 months). The mean maximum ablated diameter in the technically successful group of patients ranged from 3.5 to 7.5 cm (mean 5.1 +/- 1.3 cm). Complete necrosis was attained for eight (80%) of 10 lesions, and partial necrosis was achieved for two lesions. There were two major complications (2/10, 20%) encountered: a hemothorax (n = 1) and a bronchopleural fistula (n = 1). CONCLUSION: Although RFA using a monopolar wet electrode can create a large ablation zone, it is associated with a high rate of technical failure when used to treat inoperable non-small cell lung malignancies.  相似文献   

15.

Objective

We wished to compare the in-vitro efficiency of wet radiofrequency (RF) ablation with the efficiency of dry RF ablation and RF ablation with preinjection of NaCl solutions using excised bovine liver.

Materials and Methods

Radiofrequency was applied to excised bovine livers in a monopolar mode for 10 minutes using a 200 W generator and a perfused-cooled electrode with or without injection or slow infusion of NaCl solutions. After placing the perfused-cooled electrode in the explanted liver, 50 ablation zones were created with five different regimens: group A; standard dry RF ablation, group B; RF ablation with 11 mL of 5% NaCl solution preinjection, group C; RF ablation with infusion of 11 mL of 5% NaCl solution at a rate of 1 mL/min, group D; RFA with 6 mL of 36% NaCl solution preinjection, group E; RF ablation with infusion of 6 mL of 36% NaCl solution at a rate of 0.5 mL/min. In groups C and E, infusion of the NaCl solutions was started 1 min before RF ablation and then maintained during RF ablation (wet RF ablation). During RF ablation, we measured the tissue temperature at 15 mm from the electrode. The dimensions of the ablation zones and changes in impedance, current and liver temperature during RF ablation were then compared between the groups.

Results

With injection or infusion of NaCl solutions, the mean initial tissue impedance prior to RF ablation was significantly less in groups B, C, D, and E (43-75 Ω) than for group A (80 Ω) (p < 0.05). During RF ablation, the tissue impedance was well controlled in groups C and E, but it was often rapidly increased to more than 200 Ω in groups A and B. In group D, the impedance was well controlled in six of ten trials but it was increased in four trials (40%) 7 min after starting RF ablation. As consequences, the mean current was higher for groups C, D, and E than for the other groups: 401 ± 145 mA in group A, 287 ± 32 mA in group B, 1907 ± 96 mA in group C, 1649 ± 514 mA in group D, and 1968 ± 108 mA in group E (p < 0.05). In addition, the volumes of RF-induced coagulation necrosis were greater in groups C and E than in group D, which was greater than in groups A and B than in group E (p < 0.05); 14.3 ± 3.0 cm3 in group A; 12.4 ± 3.8 cm3 in group B; 80.9 ± 9.9 cm3 in group C; 45.3 ± 11.3 cm3 in group D and 81.6 ± 8.6 cm3 in group E. The tissue temperature measured at 15 mm from the electrode was higher in groups C, D and E than other groups (p < 0.05): 53 ± 12℃ in group A, 42 ± 2℃ in group B, 93 ± 8℃ in group C; 79 ± 12℃ in group D and 83 ± 8℃ in group E.

Conclusion

Wet RF ablation with 5% or 36% NaCl solutions shows better efficiency in creating a large ablation zone than does dry RF ablation or RF ablation with preinjection of NaCl solutions.  相似文献   

16.
PURPOSE: A multiple-electrode radiofrequency (RF) system was developed based on switching between electrodes that allows for the simultaneous use of as many as three electrically independent electrodes. The purpose of this study was to determine if each multiple-electrode ablation zone is identical to an ablation zone created with conventional single-electrode mode. MATERIALS AND METHODS: Nine female domestic pigs (mean weight, 90 kg) were used for this study. A prototype monopolar multiple-electrode RF ablation system was created with use of an RF generator and an electronic switching algorithm. A maximum of three electrodes can be used simultaneously by switching between electrodes at each impedance spike (30 omega greater than baseline levels). A total of 39 zones of ablation were created at open laparotomy in pig livers with use of a conventional single electrode (n = 9), two single electrodes simultaneously (n = 6 ablations; 12 ablation zones), or three single electrodes simultaneously (n = 6 ablations; 18 ablation zones). RF electrodes were spaced in separate lobes of the liver when multiple zones of coagulation were created simultaneously. Animals were euthanized after RF ablation, livers were removed, and ablation zones were sectioned and measured. RESULTS: Zones of coagulation created simultaneously with two or three electrodes were equivalent to ablation zones created with use of conventional single-electrode ablation. No significant differences were observed among control animals treated with a single electrode, those with two separate zones of ablation created simultaneously, and those with three simultaneously created ablation zones in terms of mean (+/-SD) minimum diameter (1.6 cm +/- 0.6, 1.6 cm +/- 0.5, and 1.7 cm +/- 0.4, respectively), maximum diameter (2.0 cm +/- 0.5, 2.3 cm +/- 0.5, 2.2 cm +/- 0.5, respectively), and volume (6.7 cm3 +/- 3.7, 7.4 cm3 +/- 3.8, and 7.8 cm3 +/- 3.9; P > .30, analysis of variance, pairwise t-test comparisons). CONCLUSIONS: A rapid-switching multiple-electrode RF system was able to simultaneously create as many as three separate ablation zones of equivalent size compared with single-electrode controls. This system would allow physicians to simultaneously treat multiple tumors, substantially reducing procedure time and anesthesia risk.  相似文献   

17.
Thermal tumour ablation techniques such as radiofrequency (RF) ablation are applied for radical removal of local tumours as an easier, less invasive alternative to surgical resection. A serious drawback of thermal ablation, however, is that the ablation area cannot be accurately assessed during the procedure. To achieve real-time feedback and exact and safe ablation, a superfine thermocouple-needle system (TNS) comprising a 0.25-mm diameter thermocouple embedded in a 22-G, 15-cm-long needle was devised and efficacy was tested in vitro using porcine livers (n = 15) and in vivo using rabbit back muscles (n = 2) and livers (n = 3). A 17-gauge RF electrode with a 2 cm active tip was used for ablation. The TNS was inserted 1 cm from the active tip of the RF electrode and liver temperature around the electrode was measured concurrently. The RF current was cut off when the temperature reached 60°C or after 5 min at ≥50°C. Porcine livers and rabbit back muscles were then cut along a plane passing through the axes of the electrode and the TNS. In rabbit livers, contrast-enhanced CT was performed to evaluate ablation areas. Ablation areas in cut surfaces of porcine livers exhibited well-defined discoloured regions and the TNS tip precisely pinpointed the margin of the ablation area. Contrast-enhanced CT of rabbit livers showed the TNS tip accurately located at the margin of areas without contrast enhancement. These results indicate that the TNS can accurately show ablation margins and that placing the TNS tip at the intended ablation margin permits exact thermal ablation.  相似文献   

18.
This in vitro investigation characterized temperature changes associated with radiofrequency (RF) energy induced heating of bovine capsular tissue using newly developed, temperature-controlled monopolar (Vulcan RF system and Vulcan, TAC-S Electrothermal Probe) and bipolar (VAPR II RF system and VAPR TC RF electrode) RF systems and electrodes. Bovine capsular tissue samples were placed in a saline bath maintained at room temperature. Both RF generators were used at settings of 75 degrees C and 40 W. The RF electrodes were placed in stationary positions on the tissue samples and activated for 1- to 10-s. A fluoroptic thermometry system was utilized to record temperatures at the RF electrode-tissue interface at 1-s intervals. The results indicated that the mean tissue temperatures for the monopolar RF electrode tended to be higher than those produced by the bipolar RF electrode, especially during the 2- to 10-s RF delivery time intervals (P<0.05). Notably, during the 2- to 10-s time intervals the monopolar RF electrode produced mean tissue temperatures that exceeded the set temperature of 75 degrees C (range of differences +1.2 to +15.7 degrees C highest mean temperature 90.7 degrees C). By comparison, the bipolar RF electrode maintained tissue temperatures relatively close to the set temperature(range of differences -3.2 to +2.7 degrees C; highest mean temperature 77.7 degrees C). These findings provide basic temperature profiles for the two new temperature-controlled RF devices.  相似文献   

19.
The purpose of this paper was to demonstrate the efficacy of the dual probe bipolar radiofrequency (RF) system with the perfused-cooled electrodes inducing coagulation necrosis in the ex vivo bovine liver. The perfused-cooled electrode that allows simultaneous internal cooling and interstitial hypertonic saline perfusion has been developed for RF ablation (RFA). RF was applied to excised bovine liver in a bipolar mode at 150 W using a 200 W generator with two perfused-cooled electrodes for 10 min. After placing the electrodes at 3 cm spacing in the explanted liver, 45 ablation zones were created with three different regimens: Group A, using both intraelectrode cooling and interstitial perfusion; group B, using only the intraelectrode cooling; and group C, using only interstitial perfusion. In groups A and C, RFA was performed with the infusion of 6% hypertonic saline at the rate of 2 ml min(-1). During RFA, we measured the tissue temperature at the midpoint between the two electrodes. The dimensions of the ablation zones and the changes in impedance, currents and liver temperature during RFA were compared in these three groups. The mean tissue impedance during RFA in group A (56.7+/-21.7 Omega) and group C (56.9+/-20.6 Omega) was significantly lower than group B (112+/-19.7 Omega) (p<0.001). The mean current was higher in group A (1765+/-128 mA) than groups B (760+/-321 mA) and C (1298+/-349 mA) (p<0.05). In addition, the shortest vertical diameter of coagulation necrosis was greater in groups A (4.9+/-0.5 cm) and C (4.6+/-0.7 cm) than in group B (3.5+/-0.4 cm) (p<0.05). The temperature at the mid-point between the two probes was higher in group A than other groups: 99 degrees C in group A, 88.9 degrees C in group B, and 94.3 degrees C in group C (p>0.05). The ratios of the diameter of the long-axis to the diameter of the vertical-axis of groups A, B and C were 1.1+/-0.1, 1.2+/-0.1, and 1.1+/-0.2, respectively (p<0.05). Bipolar RFA using intraelectrode cooling and the interstitial saline perfusion simultaneously produced ablation zones significantly larger than the area produced by only one measure.  相似文献   

20.
Purpose To evaluate the usefulness of a guiding needle for radiofrequency (RF) ablative treatment of liver tumors. Methods Forty-two patients, 38–78 years old (57 ± 17), with 42 liver tumors (18 HCC, 24 colon cancer metastases) underwent RF ablation using a 14-gauge guiding needle with an external insulated sheath in which any 18-gauge or smaller needle can be placed, including a specially designed 3.5 cm LeVeen RF electrode. One guiding needle was used in 20 tumors to provide biopsy and RF treatment in a single puncture. Three to five guiding needles were loaded in 22 tumors measuring 35 to 64 mm in their largest diameter before starting RF treatment requiring multiple overlapping RF applications. Results In the 20 RF treatments combined with biopsy, the biopsy was always contributive. Because of pre-positioning of the sheath, postbiopsy modifications (bleeding or air artifacts) did not hinder subsequent RF treatment. The 22 large tumors received 5 to 12 RF applications (mean = 6.8) through the three to five preloaded guiding needles. The RF ablation zones measured 46 to 94 mm (mean = 55) in their largest dimension, with ablative margins in all cases. After 8 to 32 months (mean = 20), 14 of the 22 tumors are considered completely destroyed on computed tomography follow-up and one tumor seeding has been found. Conclusion The Leveen CoAccess needle allows precise tumor targeting when treating large tumors requiring multiple RF applications. It allows biopsies combined with RF ablation through a single tract. Presented at the 27th SIR meeting (Baltimore 2002).  相似文献   