1.
PURPOSE: Evidence supporting the delivery of bronchodilators with a metered-dose inhaler and a valved holding chamber (MDI+VHC) in place of a small-volume nebulizer (SVN) is discussed, and the steps taken to accomplish such a conversion program at one institution are described. SUMMARY: Double-blind, randomized studies in patients with acute exacerbations of asthma have demonstrated that higher doses of albuterol delivered by MDI+VHC (4-10 puffs per dose) are as effective as 2.5 mg of albuterol sulfate delivered by SVN. Three double-blind studies support the conclusion that the two methods are equivalent with respect to both efficacy and adverse effects in patients with chronic obstructive pulmonary disease. MDI+VHC offers practical advantages over SVN, including the capacity for home use by the patient, portability, less setup time, and no need for daily disinfection. Pharmacists and respiratory therapists obtained approval through the pharmacy and therapeutics committee for respiratory therapists to convert orders for bronchodilators delivered by SVN to administration by MDI+VHC. The conversion policy allows physicians to override it, but none have exercised this option. On intensive care units (ICUs), the policy resulted in a 53% increase in the use of MDI+VHC during the six-month period after it went into effect. Respiratory therapists have been less thorough in implementing the policy for non-ICU patients. CONCLUSION: Delivery of bronchodilators by MDI+VHC is as effective as delivery by SVN but offers several advantages. A policy to switch patients from SVN to MDI+VHC for bronchodilator administration met with limited success.  相似文献   

2.
STUDY OBJECTIVE: To compare the in vitro aerosol deposition characteristics of several commercially available valved holding chamber (VHC) and spacer devices used with a fluticasone metered-dose inhaler (MDI). DESIGN: In vitro aerosol deposition study SETTING: University-affiliated research center. DEVICES: Seven VHC devices: BreatheRite, E-Z Spacer, EasiVent, AeroChamber, InspirEase, OptiChamber, and Space Chamber. Six spacer devices: OptiHaler, Aerosol Cloud Enhancer (ACE), Gentle-Haler, MediSpacer, Ellipse, and a 6-inch tube (1-inch inside diameter). INTERVENTION: The respirable dose (aerosol particles 1-5 microm) of fluticasone was determined by sampling 10 220-microg actuations from five runs with each spacer or VHC plus MDI combination, by using a well-established in vitro cascade impactor method. MEASUREMENTS AND MAIN RESULTS: Fluticasone aerosol was washed from the impactor with methanol and quantified by means of high-performance liquid chromatography. Differences among outcomes were determined with analysis-of-variance testing. Among spacers, Ellipse had the highest respirable dose (104 microg, p < 0.01). Respirable doses for the 6-inch tube (74.3 microg), Gentle-Haler (81.7 microg), and MediSpacer (82.6 microg) were no different from that of the MDI (p > 0.05), whereas respirable doses of OptiHaler (44.6 microg) and ACE (47.2 microg) were less than those of all other spacers (p < 0.001). Among VHC devices, respirable doses from EasiVent (35.6 microg), AeroChamber (47.0 microg), InspirEase (52.7 microg), OptiChamber (53.1 microg), and Space Chamber (58.3 microg) were not different (p > 0.05), whereas BreatheRite (13.1 microg) and E-Z Spacer (27.3 microg) respirable doses were less than those of the other VHC devices (p < 0.05). CONCLUSION: Spacers and VHC devices available in the United States do not demonstrate equivalent in vitro performance with the fluticasone MDI. The difference between highest and lowest respirable doses in each device category would likely lead to clinically relevant differences in the quantity of fluticasone delivered to a patient.  相似文献   

3.

AIMS

To compare the respirable dose delivery of the hydrofluroalkane fluticasone propionate (HFA-FP) via an optimally prepared Aerochamber Plus spacer (AP), via a Synchro-Breathe (SB) device, and pMDI Evohaler (EH).

METHODS

Seventeen mild to moderate asthmatics completed the study using a randomized, double-blind, double-dummy, three way crossover design. Single doses of placebo or HFA-FP 2.0 mg were administered via the EH, AP, and SB devices. The overnight urinary cortisol : creatinine ratio (OUCC) was measured at baseline and after each dose.

RESULTS

Significant suppression of OUCC occurred from baseline with AP and SB but not EH devices (geometric mean fold suppression, 95% CI): AP: 3.18 (2.29, 4.36), P < 0.001; SB: 1.79 (1.31, 2.40), P = 0.001; EH: 1.12 (0.69, 1.44), p = 0.37 (equating to 68%, 45% and 9% falls, respectively). Significant differences in OUCC between devices were as follows: (geometric mean fold difference, 95% CI): AP vs. EH. 2.83 (2.09, 3.82), P < 0.001; AP vs. SB: 1.78 fold (1.21, 2.60), P = 0.003; SB vs. EH: 1.59 (1.09, 2.31), P = 0.013 (equating to 65%, 44% and 37% differences, respectively).

CONCLUSIONS

The use of an optimally prepared AP spacer and breath actuated SB device, when compared with pMDI, significantly increased the respirable dose of HFA-FP.

WHAT IS ALREADY KNOWN ABOUT THIS SUBJECT

  • Respirable dose delivery of inhaled steroids may be improved by the use of conventional valved holding chambers (such as the Aerochamber Plus spacer), but these are bulky and cumbersome to use.
  • A novel compact breath actuated device with integrated vortex chamber (Synchro-Breathe) has been developed to overcome these problems,
  • The lung bioavailability of inhaled fluticasone propionate is dependant on respirable dose delivery, and hence the performance of inhaler devices can be quantified by measuring the degree of adrenal suppression as a surrogate for relative lung dose.

WHAT THIS STUDY ADDS

  • This study compares the respirable dose delivery (as relative adrenal suppression) of inhaled fluticasone delivered via Synchro-Breathe, conventional pMDI (Evohaler), and an optimally prepared Aerochamber Plus spacer in patients with asthma.
  • The Aerochamber Plus and the Synchro-Breathe devices produced significantly higher respirable dose delivery of inhaled fluticasone than the pMDI, in terms of the relative degree of adrenal suppression.
  相似文献   

4.
STUDY OBJECTIVE: To compare in vitro aerosol deposition from a beclomethasone dipropionate metered-dose inhaler (MDI) containing hydrofluoroalkane propellant with that of the MDI in combination with two common valved holding chambers (VHCs) to evaluate how these VHCs affect the respirable dose of beclomethasone dipropionate. DESIGN: In vitro aerosol deposition study. SETTING: University research center. DEVICES: Beclomethasone dipropionate hydrofluoroalkane MDI alone, the MDI with OptiChamber VHC, and the MDI with AeroChamber-Plus VHC. INTERVENTION: The respirable dose (1-5-microm aerosol particles) of beclomethasone dipropionate was determined by sampling 10 80-microg actuations from five runs with each configuration (MDI alone, MDI with OptiChamber, and MDI with AeroChamber-Plus), using a well-established in vitro cascade impactor method. MEASUREMENTS AND MAIN RESULTS: Beclomethasone dipropionate aerosol was washed from the impactor with 50% methanol and quantified by means of high-performance liquid chromatography. Differences among outcomes were determined by using analysis of variance. Mean beclomethasone dipropionate respirable dose from AeroChamber-Plus (27.2 +/- 10.0 microg/actuation) was not significantly different (p>0.05) from that of the MDI alone (29.0 +/- 7.0 microg/actuation). OptiChamber respirable dose (12.8 +/- 6.0 microg/actuation) was less than half that produced by either the AeroChamber-Plus or the MDI alone (p=0.013). CONCLUSIONS: The OptiChamber and AeroChamber-Plus VHCs do not demonstrate equivalent in vitro performance when used with a beclomethasone dipropionate MDI that contains hydrofluoroalkane propellant. The respirable dose of beclomethasone dipropionate aerosol from the hydrofluoroalkane MDI was decreased by only 6% when the MDI was mated to an AeroChamber-Plus VHC and by 56% when used with an OptiChamber VHC.  相似文献   

5.
The relationship between saliva and serum paracetamol levels was investigated in ten healthy male volunteers. The salivary and serum paracetamol levels showed significant correlation with each other. The salivary and serum paracetamol concentration ratio was highly dependent on sampling time. The salivary and serum paracetamol half-lives showed significant correlation with each other while the area under curve of paracetamol concentration in saliva and serum failed to show significant correlation.  相似文献   

6.
Doxorubicin is one of the most potent anti-tumor agents generally used in the treatment of bone cancer. A simple and sensitive HPLC method was developed and validated for the assay of doxorubicin. The method used a C18 Luna microbore column (50 x 1 mm) with a fluorescent detector (505 nm Ex. and 550 nm Em.). The mobile phase consisted of water-acetonitrile-acetic acid (80:19:1, v/v/v, pH 3.0) and the flow rate was 0.1 ml min(-1). Daunomycin was used as the internal standard. This isocratic system required a 10-min run-time, giving a detection limit of 0.02 ng (0.035 pmol per injection). Standard curves were linear over the concentration range of 0.01-0.1 microg ml(-1). Relative standard deviations (R.S.D.) for the within-day, day-to-day precision, and the accuracy measurement for the assay were less than 4.0, 3.2, and 4.1%, respectively. This HPLC method was used to study the in vitro release characteristics of doxorubicin from implantable drug delivery system.  相似文献   

7.
A comparison was made between the results of acetylator phenotyping by isoniazid (INH) half-life measurements based on samples taken for 6 h after a single oral dose (200 mg), and by determination of the ratio of acetylisoniazid (Ac.INH) to isoniazid in the 3 h samples. In the 32 subjects, examined, there was complete agreement about classification of the subject as a fast (t1/2 less than 130 min; Ac.INH/INH greater than 1.5) or slow acetylator (t1/2 greater than 130 min; Ac.INH/INH less than 1.5). The single sample test appears to be as reliable as the more time-consuming isoniazid half-life method.  相似文献   

8.
The purpose of this study was to compare three valved holding chambers (VHC) with facemasks attached. One VHC (AeroChamber Max[TM] with medium mask) was made with materials that dissipate surface electrostatic charge, and the others (OptiChamber Advantage and ProChamber[TM] with pediatric facemask) were made from non-conducting materials. The OptiChamber Advantage and ProChamber VHCs were each washed with an ionic detergent and drip dried before testing to minimize surface electrostatic charge. The AeroChamber Max VHCs were tested "out of the package" and also after wash, rinse, and drying. An infant face model incorporating an electrostatic filter in the oral cavity was connected to a breath simulator using a standard waveform for a small child. The fit of each VHC with facemask was demonstrated by agreement of inspiratory flow measurements between a pneumotachograph connected to the system with those set on the simulator. An HFA-fluticasone propionate metered dose inhaler (MDI; 125 microg/dose) was inserted into the VHC, two actuations were delivered, and the filters were subsequently assayed using high-pressure liquid chromatography (HPLC). Testing and sample assay order was randomized, and HPLC assays were undertaken blinded. Drug delivery efficiency expressed as a percentage of the total dose of fluticasone propionate (250 microg) for the AeroChamber Max VHC "out-of-the-package" was 22.0(0.7)% (mean [99% CI]) and 21.2(1.5)% when pre-washed/rinsed. Results for the pre-washed ProChamber and OptiChamber Advantage VHCs were 10.2(0.55)% and 8.8(1.9)%, respectively. The more efficient delivery of medication via VHCs made from electrostatic charge dissipative materials should be considered when choosing doses for small children.  相似文献   

9.
The relationship between the amount of inhaled steroids delivered from pressurized metered-dose inhalers used with their recommended holding chambers and age of the patients using these devices was studied in an open randomised cross-over filter study. We recruited 1-2-month-old healthy infants (n = 21), 2-3-year-old asthmatics (n = 13), 4-6-year-old asthmatics (n = 15), and 10-15-year-old asthmatics (n = 20). Each child inhaled two puffs, administered by a single investigator, of both budesonide through Nebuchamber and fluticasone propionate through Babyhaler, on two occasions. Moreover, the 4-6-year-old group inhaled via both facemask and mouthpiece. Drug, collected on a filter interposed between holding chamber and patient, was analysed by high performance liquid chromatography. Filter dose, expressed in percent of the nominal dose, was analysed in a mixed effect linear regression model with age group, holding chamber and inhalation interface (facemask or mouthpiece) as fixed effects and subject as random effect. Filter dose from both holding chambers increased significantly with age, from 3% with Babyhaler and 7% with Nebuchamber in the youngest children, to 40-41% with both holding chambers in adolescents. Nebuchamber delivered more drug than Babyhaler (p = 0.002), but variability in drug delivery (about 11%) was similar between holding chambers. Filter dose decreased from 35% to 22% with Babyhaler, and from 42% to 27% with Nebuchamber when using a mouthpiece rather than a facemask (p < 0.0001). Delivery of inhaled steroids used with their recommended holding chambers depends from age and holding chamber, but also from the inhalation interface. Lung deposition and clinical studies comparing inhalation from holding chambers with mouthpiece and facemask are urgently required.  相似文献   

10.
11.
A simple and sensitive fluorometric assay method for taurine (2-aminoethanesulfonic acid) has been developed. For the separation of taurine, high voltage paper electrophoresis subsequent to column chromatographic procedures was employed. Fluorescent product of taurine was yielded by spraying fluorescamine (4-phenylspiro [furan-2(3H), 1'-phthalan]-3, 3'-dione) and borate buffer on the paper, and the fluorescence was assayed spectro-fluorometrically after eluting with 50% ethanol. The linear relationship between the concentration of taurine and fluorescence developed was achieved over the concentration ranges of 0.5-10 nmoles, and the recoveries obtained were 90-100%. The specificity of this method for taurine was satisfactory and structural analogues involved in the metabolic pathway of taurine did not interfere with the assay. Examples for tissue levels of taurine in various organs of the rat as determined by this new method are also presented.  相似文献   

12.
The horizontal Ussing chamber method described here allows performance of transport studies on pig nasal respiratory mucosa under conditions simulating reality in that it mimics the air-mucosa interface. The transport of testosterone and mannitol through pig nasal mucosa in the horizontal Ussing chamber was investigated using both liquid and air mucosal interfaces. There were no significant differences in either the bioelectrical parameters (transmucosal electrical resistance, R, potential difference, PD, and short circuit current, I(sc)) or the apparent permeability (P(app)) of the mucosa to testosterone or mannitol between the liquid and air interface experiments. The histological study showed that the epithelial cell layer tolerates exposure to the air interface well. The P(app) equation was developed to correct for substance binding to the wall of the receiver chamber. The mean values +/- SD of R, PD, and I(sc) for the mucosae in the study were 75.0 +/- 28.0 Omegacm(2), (-4.53) +/- 3.46 mV and 58.6 +/- 28.8 microA/cm(2), respectively. The corrected P(app) for testosterone with and without the mucosal air interface were 9.82. 10(-6) +/- 11.41. 10(-6) cm/s and 32.24. 10(-6) +/- 31.12. 10(-6) cm/s, respectively. The P(app) values for mannitol with and without the air interface were 2.26. 10(-6) +/- 1.42. 10(-6) cm/s and 3.12. 10(-6) +/- 1.72. 10(-6) cm/s, respectively.  相似文献   

13.
The treatment of both the bronchoconstriction and inflammatory aspects of asthma simultaneously by a single pressurized metered dose inhaler (pMDI) represents a significant advance in convenience to the patient. However, a valved holding chamber (VHC) may still be needed to reduce the coarse component of the dose that is likely to deposit in the oropharyngeal region, and a small sized device may offer significant advantages to the patient from the standpoint of compliance with therapy. VHCs representing small (adult AeroChamber Plus with mouthpiece, 149-mL) and large (Volumatic, 750-mL) devices have been compared in an in vitro evaluation with Seretide/Advair (hydro-fluoro alkane [HFA]-formulated fluticasone propionate [FP = 125 microg/dose] and salmeterol xinafoate [SX = 25 microg/dose]) by Andersen Mark-II eight-stage impactor operated at 28.3 L/min following compendial methodology. Fine particle fraction, based on the size range from 1.1 to 4.7 microm aerodynamic diameter, from either large or small VHCs with either component (69-79%) was similar [p > or = 0.08], and significantly greater than that from the pMDI alone (approximately 40%) [p < 0.001]. Fine particle dose emitted by the VHCs for SX (8.2 +/- 0.8 microg for the AeroChamber Plus and 7.7 +/- 0.5 microg for the Volumatic) were comparable, and also similar to the fine particle dose delivered by the pMDI when used without a VHC (7.6 +/- 0.6 microg). Fine particle doses for the FP component delivered by the two VHCs (46.4 +/- 3.4 microg for the AeroChamber Plus and 46.3 +/- 2.7 microg for the Volumatic) were equivalent, but were slightly greater than the corresponding fine particle dose from the pMDI alone (39.1 +/- 2.6 microg). However, this difference (approximately 20%) is close to the limit of resolution based on intermeasurement variability and is unlikely to have clinical significance, given the interpatient variability seen with inhaled drug therapy. It is therefore concluded that either of these VHCs has equivalent in vitro performance with this combination formulation in terms of the portion of the dose emitted from the pMDI that is likely to reach the receptors in the lungs.  相似文献   

14.
15.
16.
A simple appliance for the prevention of postoperative thrombo-embolic disease is described and a plea is made for its use in a multicentre trial. A modified device should be placed in the beds of all high risk medical, surgical and obstetric patients.  相似文献   

17.
We investigated the effects of sleep-inducing agents with different mechanisms of action on the loss of the righting reflex induced by isoflurane or a mixture of medetomidine, midazolam, and butorphanol (MMB), followed by atipamezole reversal. Chlorpromazine and brotizolam delayed recovery from both types of anesthesia, whereas the melatonin receptor agonist ramelteon had no effect. The orexin receptor antagonist suvorexant delayed recovery from anesthesia only in the case of MMB, while the sleep-promoting supplement glycine only delayed recovery in the case of isoflurane. These results suggest that the simple comparison method is applicable for testing substances expected to exert sleep-inducing effects.  相似文献   

18.
1. A simple and reliable method is described for assaying 1 pg or less of acetylcholine (ACh) using a strip of clam (Mya arenaria) heart.2. Clam heart preparations generally are extremely selective for ACh. The preparation described is at least 10(5) times less sensitive to the following: acetyl coenzyme A, adrenaline, choline, dopamine, gamma-aminobutyric acid, glutamic acid, histamine, 5-hydroxytryptamine and noradrenaline.3. Because this preparation is one of the most sensitive known for detecting ACh, it should prove useful for assaying particularly low levels of this substance in biological extracts.  相似文献   

19.
20.