首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.

Backgrounds and aims

Accurate assessment of graft bile duct is important to plan surgical procedure. Magnetic resonance cholangiopancreatography (MRCP) has become an important diagnostic procedure in evaluation of pancreaticobiliary ductal abnormalities and has been reported as highly accurate. We aim to estimate the efficacy of preoperative MRCP on depicting biliary anatomy in living donor liver transplantation (LDLT), and to determine whether inaccurate preoperative imaging assessment would increase the biliary complications after LDLT.

Methods

The data of 118 cases LDLT were recorded. Information from preoperative MRCP was assessed using intraoperative cholangiography (IOC) as the gold standard. The possible risk factors of recipient biliary complications were analyzed.

Results

Of 118 donors, 84 had normal anatomy (type A) and 34 had anatomic variants (19 cases of type B, 9 cases of type C, 1 case of type E, 2 cases of type F and 3 cases of type I) confirmed by IOC. MRCP correctly predicted all 84 normal cases and 17 of 34 variant cases, and showed an accuracy of 85.6% (101/118). The incidence of biliary complications was comparable between cases with accurate and inaccurate classification of biliary tree from MRCP, and between cases with normal and variant anatomy of bile duct. While cases with graft duct opening ≤5 mm showed a significant higher incidence of total biliary complications (21.1% vs. 6.6%, P = 0.028) and biliary stricture (10.5% vs. 1.6%, P = 0.041) compared with cases with large duct opening >5 mm.

Conclusion

MRCP could correctly predict normal but not variant biliary anatomy. Inaccurate assessment of biliary anatomy from MRCP not increases the rate of biliary complications, while small-sized graft duct may cause an increase in biliary complications particularly biliary stricture after LDLT.  相似文献   

2.

Purpose

To investigate the added value of diffusion-weighted imaging (DWI) to magnetic resonance cholangiopancreatography (MRCP) in differentiating benign from malignant extrahepatic biliary strictures.

Methods

Magnetic resonance examination including, T2-weighted imaging, MRCP and DWI using different b-values (0,500,800 s/mm2) were performed in 38 patients with suspicious extrahepatic biliary strictures. Apparent diffusion coefficient (ADC) value was calculated. The signal intensity of the lesions on DWI using b = 500 and 800 s/mm2 was examined. Analysis of the DWI and MRCP images for the cause of the extrahepatic biliary stricutre was performed. Patients were further confirmed by histopathological diagnosis and follow up. Sensitivity, specificity, accuracy, positive predictive and negative predictive values were calculated for both the MRCP images and DWI.

Results

Of the 38 cases, 23 cases had malignant extrahepatic biliary strictures and 15 had benign strictures. DWI detected 21 out of the 23 malignant biliary strictures and 14 out of 15 benign biliary strictures. Malignant strictures more frequently appeared hyperintense than benign strictures on DWI using b-values of 500 and 800 s/mm2. There was a significant difference in sensitivity (91.3% vs. 73%), specificity (93.3% vs. 64.7%), accuracy (92.1% vs. 73.6%), positive predictive value (95.4% vs. 81%), and negative predictive value (87.5% vs. 64.7%) between DWI and MRCP in differentiating biliary strictures.

Conclusion

Combined evaluation using DWI added to MRCP improves the differentiation of malignant from benign extrahepatic biliary strictures.  相似文献   

3.

Purpose

To evaluate the differentiating factors for intraductal papillary mucinous neoplasm of the pancreas and chronic pancreatitis as determined by MR imaging.

Materials and methods

During a three-year period, we performed MR imaging on 33, consecutive patients with IPMN and on 41 patients with chronic pancreatitis. All IPMNs were confirmed by surgery. Two radiologists retrospectively analyzed the ductal change, the cyst shape, CBD dilatation, lymphadenopathy, and parenchymal change. The sensitivity and specificity were calculated for each MRI findings using the Chi square test. Statistically significant MR findings were further analyzed using multivariate logistic regression analysis. The diagnostic performance was evaluated according to the area under the receiver operating characteristic curve (Az) using specific MRI findings. Simple κ statistics were used to evaluate the inter-observer reliability.

Results

Statistically specific findings for IPMN compared with those for chronic pancreatitis, were duct dilatation without stricture (specificity = 95.1%, sensitivity = 75.8%, p < 0.0001), bulging ampulla (specificity = 97.6%, sensitivity = 30.3%, p < 0.0001), nodule in a duct (specificity = 100%, sensitivity = 15.2%, p < 0.0004), grape-like cyst shape (specificity = 97.6%, sensitivity = 78.8%, p < 0.0001), and nodule in a cyst (specificity = 100%, sensitivity = 24.2%, p < 0.0001). Statistically specific findings for chronic pancreatitis compared with those for IPMN, were duct dilatation with strictures (specificity = 93.9%, sensitivity = 95.1%, p < 0.0001), the presence of a stone (specificity = 97.0%, sensitivity = 56.1%, p < 0.0001), and a unilocular cyst shape (specificity = 93.9%, sensitivity = 34.1%, p < 0.0004). Duct dilatation without stricture and a grape-like cyst shape were independently associated with the IPMN. Duct dilatation with strictures was independently associated with the chronic pancreatitis. Interobserver agreement was good to excellent for each finding (κ = 0.762–1.000).

Conclusion

Highly specific findings for IPMN include duct dilatation without stricture, bulging ampulla, nodule in a duct, grape-like cyst shape, and nodule in a cyst. MRI is very useful for differentiating IPMN from chronic pancreatitis using these specific findings.  相似文献   

4.

Purpose

The purpose of this study is to assess the common MRI findings of acute cholangitis compared with those of non-acute cholangitis.

Materials and methods

During a 31-month period, we performed MRCP and contrast-enhanced MRI on 173 patients with biliary abnormalities including duct dilatation or stricture. The causes of the biliary abnormalities included biliary stone disease (n = 85), cholangiocarcinoma (n = 47), periampullary cancer (n = 20), GB cancer (n = 4), and others (n = 17). Among 173 patients, 66 consecutive patients were confirmed with acute cholangitis diagnosed according to the Tokyo guideline, and 107 patients were confirmed as having non-acute cholangitis. Two radiologists retrospectively and independently accessed the MR findings, including the cause of biliary abnormality, increased periductal signal intensity on T2-weighted images, the transient periductal signal difference, and the presence of abscess, thrombosis, and ragged duct. They also measured the dilated duct and the thickened wall. The Student t-test and the Pearson chi-square were used. The κ statistics were used to determine interobserver agreement. Logistic regression was used to identify the MR findings that predicted acute cholangitis.

Results

MRI correctly accessed the cause of biliary abnormality in 163 patients (94%). The statistically common findings for acute cholangitis were as follows: increased periductal signal intensity on T2-weighted imaging (n = 26, 39%, p < 0.05); transient periductal signal difference (n = 31, 47%, p < 0.05); abscess (n = 18, 27%, p < 0.05); thrombosis (n = 12, 18%, p < 0.05); and ragged duct (n = 11, 17%, p < 0.05). Interobserver agreement was good to excellent for each finding (κ = 0.74–0.97). The wall thickness showed a statistically significant difference between the acute cholangitis and the non-acute cholangitis group (2.65 mm:2.32 mm, p < 0.05), however, there was no significant difference in duct dilatation in the two groups. The periductal transient attenuation difference was an independent predictor of acute cholangitis (Exp (B) = 6.389, p = 0.018).

Conclusion

MRI accurately assesses the cause of biliary abnormality in patients with cholangitis. Using statistically common MR findings for acute cholangitis, MR imaging is very successful in predicting acute cholangitis.  相似文献   

5.

The aim of the study

To evaluate the diagnostic accuracy of magnetic resonance cholangiopancreatography in patients with cholestatic jaundice.

Patients and methods

Clinical, laboratory and investigational data were evaluated from 50 patients with cholestastic jaundice. MRCP findings were compared with ERCP or operative findings and appropriate clinical endpoints.

Results

The ERCP or operative findings and appropriate clinical endpoints revealed 23 patients with intra or extra hepatic biliary dilatation and 27 patients without intra or extra hepatic biliary dilatation. As regards the 23 patients with biliary dilatation, biliary dilatation was evident in 19 patients by U/S versus 23 patients by MRCP. ERCP was successful in 20 patients (87%) and was not done in three patients (13%). In cases of obstructive jaundice the sensitivity of MRCP was 100% versus 86% in choledocholithiasis and malignant detection, respectively p value <0.05.

Conclusion

MRCP is highly sensitive and specific for biliary dilatation and avoids the need for invasive imaging in most patients with cholestasis. MRCP permits reservation of ERCP to patients with a high probability of therapeutic intervention.  相似文献   

6.

Purpose

To assess the clinical usefulness of free-breathing 3D MRCP in non-cooperative patients compared conventional breath-hold 2D MRCP.

Materials and methods

We performed FB navigator-triggered 3D MRCP using prospective acquisition correction and BH 2D MRCP in 48 consecutive, non-cooperative patients among 772 patients. Thirteen patients had malignant obstruction. Two radiologists independently graded the likelihood of a malignant obstruction, the overall image quality, and the visibility of ten, individual anatomic segments of both the biliary and pancreatic duct in each sequence. The area under the ROC curve and the repeated measures analyses of variance with multiple comparisons were used for the comparison. The κ statistics were used for interobserver agreement.

Result

The diagnostic performance for detecting malignancy was significantly higher on FB MRCP (Az = 0.962) than on either BH SS-RARE (Az = 0.820, P < 0.0185) or MS-HASTE MRCP (Az = 0.816, P < 0.0067). Interobserver agreement was excellent for FB MRCP (κ = 0.889) and fair for both BH SS-RARE (κ = 0.578) and MS-HASTE MRCP (κ = 0.49). FB MRCP had a significantly higher technical quality than BH MRCP (P < 0.001). FB MRCP was seen to have statistically better visibility of peripheral IHD, right main IHD, CHD, cystic duct, and CBD than BH MRCP (P < 0.001). FB MRCP and BH SS-RARE MRCP had statistically better visibility of both the left main IHD and pancreatic duct than did BH MS-HASTE MRCP (P < 0.001).

Conclusion

FB 3D MRCP is useful for non-cooperative patients in whom conventional BH 2D methods cannot be used successfully.  相似文献   

7.

Objective

To determine the utility of CT cholangiography (CT-Ch) in preoperative evaluation of the biliary anatomy of living-donor liver transplantation (LDLT) donors when magnetic resonance cholangiopancreatography (MRCP) is inconclusive.

Materials and methods

Over a 2-year period, 22 potential living liver donors underwent contrast-enhanced CT-Ch for preoperative evaluating biliary anatomy due to inconclusive results on MRCP and subsequently donated their right hepatic lobe. Nineteen of them underwent intraoperative cholangiography and were included in this study. Two radiologists retrospectively reviewed both MRCP and CT-Ch with 1-month interval and documented the types of bile duct branching patterns and visualization score of intrahepatic bile ducts (4-point scale).

Results

There were no complications associated with CT-Ch examinations. CT-Ch was concordant with the reference standard in 18/19 (95%) including 7/8 typical branching type and 11/11 anomalous branching types. MRCP was concordant with the reference standard in 14/19 (74%) including 4/8 typical branching types and 10/11 anomalous branching types. The discordant case by CT-Ch was the identification of a tiny accessory right intrahepatic duct joining the common bile duct which was not visualized on intraoperative cholangiography. CT-Ch showed higher visualization score (mean, 3.9) than MRCP (mean, 2.6) (P < .001).

Conclusion

CT-Ch can be effectively used for the depiction of the branching pattern of the bile duct at the hepatic hilum when MRCP is inconclusive.  相似文献   

8.

Purpose

The purpose of our study was to compare three-dimensional (3D) negative-contrast CT cholangiopancreatography (3D-nCTCP) with 3D MR cholangiopancreatography (3D-MRCP) for the diagnosis of obstructive biliary diseases.

Materials and methods

3D-nCTCP and 3D-MRCP were performed on seventy clinically documented obstructive biliary diseases patients. The accuracy of each technique in determining the location and cause of biliary obstruction was evaluated compared with the final clinical diagnoses.

Results

Both methods achieved 100% of accuracy in the diagnosis of the presence and location of biliary obstruction, and had a similar sensitivity, specificity, accuracy in differentiating benign from malignant biliary obstruction or calculous from noncalculous biliary obstruction (p > 0.05). At 3D-nCTCP, six patients with stones were misinterpreted as cholangitis (N = 2), papillitis (N = 3), or bile duct adenocarcinoma (N = 1); two metastases were mistaken as acute pancreatitis or pancreatic head carcinomas, and one intrahepatic cholangiocarcinoma was misled as bile duct adenoma. At 3D-MRCP, one small stone, one ampullary adenoma, and one intrahepatic cholangiocarcinoma were mistaken as cholangitis, ampullary stone, and intrahepatic bile duct stone, respectively, and three gallbladder carcinomas and another intrahepatic cholangiocarcinoma were misdiagnosed as hilar cholangiocarcinoma (N = 3) or common hepatic duct stone (N = 1); four metastases were mistaken as pancreatic head carcinomas (N = 3) or distal cholangiocarcinoma (N = 1). The overall accuracy in making specific diagnosis of the cause of biliary obstruction was 87.1% for 3D-nCTCP and 84.3% for 3D-MRCP, respectively, (p > 0.05).

Conclusion

3D-nCTCP has the similar effects as 3D-MRCP for the diagnosis of biliary obstruction and, the location and the cause of biliary obstruction. In view of selected cases contraindications for MRI, 3D-nCTCP is a potential substitute.  相似文献   

9.

Purpose

To compare the sensitivity and specificity of contrast-enhanced ultrasonography (CEUS) and 4-slice multidetector-computed tomography (MDCT) in the detection of liver metastases in patients with colorectal cancer (CRC).

Materials and methods

Candidates for this prospective study were 461 consecutive patients referred to the Department of Colorectal Surgery, Aarhus University Hospital with primary or local recurrence of CRC. The patients underwent liver ultrasonography (US), CEUS, MDCT and intraoperative ultrasonography (IOUS). Fine-needle biopsy was performed on all suspicious lesions. The examinations were interpreted blindly and the combination of US, CEUS, biphasic MDCT, IOUS, follow up and biopsy was the gold standard.

Results

Three hundred and sixty-five patients were included. All patients had undergone preoperative US, CEUS and MDCT and 65.5% had received IOUS. The gold standard found liver metastases in 54 patients (14.8%). Multidetector CT found significantly more metastases than CEUS in 15 (28%) of the patients (p = 0.02). In a patient-by-patient analysis MDCT had a non-significantly higher sensitivity in the detection of liver metastases compared to CEUS (0.89 versus 0.80, p = 0.06). The specificity of CEUS (0.98) was slightly better than that of MDCT (0.94) (p = 0.02).

Conclusion

Multidetector CT found significant more metastases than CEUS, and MDCT had in patient-by-patient analysis a non-significant better sensitivity (p = 0.06) in detecting liver metastases in patients with CRC.  相似文献   

10.

Purpose

Magnetic resonance cholangiopancreatography (MRCP) has now largely substituted endoscopic retrograde cholangiopancreatography (ERCP) in evaluating the biliary tree in adults giving its high sensitivity and specificity. Whilst smaller series published to date suggests this may be extrapolated to the paediatric population, its routine use in children is still debatable. The aim of our study is therefore to review the utility of MRCP in a large series of paediatric patients.

Methods and materials

All MRCPs performed in our institution were examined for diagnostic quality, spectrum of diagnoses and correlation with direct cholangiography (DC) were available. Correlation with histopathology results and final clinical diagnosis was made in the subset of patients in whom a MRCP had been performed to evaluate the presence of primary sclerosing cholangitis (PSC).

Results

There were 245 MRCP examinations performed on 195 patients and 219 were diagnostic. There was 100% MRCP and DC concordance in the 16 cases where both had been performed. MRCP yielded a sensitivity of 89% in the subset of patients with PSC.

Conclusion

MRCP was a valuable diagnostic tool in our paediatric population. Image quality is sufficiently diagnostic and shows good correlation with clinical diagnosis in conditions encountered in our population, including primary sclerosing cholangitis, post liver transplant biliary strictures, post surgical complications, dilated common bile ducts, choledochal cysts, cholelithiasis and choledocholithaisis.  相似文献   

11.

Aim

To describe the typical CEUS pattern of pancreatic lesions and to evaluate the diagnostic accuracy of Contrast-enhanced ultrasound (CEUS) in their characterization.

Materials and methods

All US and CEUS examinations of focal pancreatic masses performed in six centers during a period of five years were reviewed. Inclusion criteria were: focal pancreatic mass pathologically proved, visible at ultrasound (US) and studied with CEUS. All lesions were then evaluated for size, aspect and enhancement pattern. Sensitivity, specificity, positive and negative predictive values with 95% CIs were calculated to define diagnostic accuracy of CEUS in respect to pathology. Diagnostic confidence of US and CEUS, discerning between benign and malignant lesions, were represented by using ROC (receiver operating characteristics) curves. Agreement was evaluated by means of k statistics.

Results

1439 pancreatic lesions were included. At CEUS the lesions were divided into solid (89%) and cystic (12%) masses and classified into six and eight categories, respectively. Among the solid lesions, adenocarcinomas were characterized with an accuracy of 87.8%. Among the cystic lesions, cystic tumors were diagnosed with an accuracy of 97.1%. ROC curve area increased from 0.637 for US to 0.877 for CEUS (p < 0.0001). Inter-observer agreement was slightly higher for solid (k = 0.78) than cystic (k = 0.62) lesions. In none of the centers side effects were reported.

Conclusion

CEUS is accurate in the characterization of pancreatic lesions. CEUS should be considered as a complementary imaging method for pancreatic lesions characterization.  相似文献   

12.

Objectives

The purpose of this study was to determine the performance of the conventional ultrasonography (US) and sonoelastography (SE) in three conditions of all lesions, confined to mass, and confined to non-mass lesion and to compare the performance of each modality between mass and non-mass lesion.

Materials and methods

A total 364 patients with 375 lesions were evaluated with US and subsequently SE before performing US-guided biopsy. Two radiologists retrospectively analyzed conventional US and elasticity images by consensus. The US findings were classified as mass or non-mass lesion. With final pathology as reference, in each case of all lesions, masses, and non-mass lesions, areas under the ROC curves (Az) were calculated and compared for the two techniques. The comparison of Az values between the curves for US and SE, and between the curves for mass and non-mass lesion was performed.

Results

Among 375 lesions, 104 (28%) lesions were malignant and 271 (72%) lesions were benign. 36 (9.6%) of 375 lesions were classified as non-mass lesion at US.There were statistically significant difference of performance between US and SE in cases of all lesion (p = 0.003) and mass (p = 0.023). However, there was no statistically significant difference of performance in case of non-mass lesion (p = 0.5). Comparisons of the Az values of US and SE between mass and non-mass lesions were not statistically significant (p = 0.745, p = 0.415, respectively).

Conclusion

There was no statistically significant difference of performance of US and SE between mass and non-mass lesion.  相似文献   

13.

Objective

To evaluate the contribution of power Doppler ultrasonography (PDUS) to breast imaging reporting and data system ultrasonography (BI-RADS US) categorization of solid breast masses.

Materials and methods

Totally 94 solid lesions with histopathological results in 49 patients were included in the study. US features of the lesions were classified according to American College of Radiologists (ACR) BI-RADS US lexicon. Lesions were evaluated qualitatively according to their PDUS properties and quantitatively with spectral analysis. Hypervascularity, penetration of vessels into the mass or branching-disordered course and resistivity index values higher than 0.85 were accepted as probable malignant criteria.

Results

Fifty-five of 94 lesions were benign (58.5%), while 39 (41.5%) were malignant histopathologically. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of US and PDUS in the diagnosis of malignant lesions were 100%, 58.2%, 62.9%, 100% and 71.8%, 81.8%, 73.7%, 80.4%, respectively. Criteria used for the distinction of malignant and benign lesions like number of vessels (p < 0.05), distribution of tumoral vessels, morphology of vessels and resistivity index values higher than 0.85 showed statistically significant difference (p < 0.001). When sonographic findings were combined with PDUS and spectral analysis findings, sensitivity, specificity, PPV and NPV were 100%, 52.7%, 60% and 100%, respectively.

Conclusion

PDUS and spectral analysis have no contribution to BI-RADS US. For the spectral analysis, when RI value is one or greater, malignancy risk significantly increases.  相似文献   

14.

Objective

To compare on-site and blinded off-site reading of baseline ultrasound (US) and contrast enhanced ultrasound (CEUS) for classification and characterisation of focal liver lesions.

Materials and methods

99 patients (57 women and 42 men, age range 18–89 years, mean age: 59 years) with 53 malignant and 46 benign liver lesions were studied with unenhanced US followed by contrast enhanced US after injection of 2.4 ml SonoVue® (Bracco, Milano, Italy). Image interpretation was performed on-site with clinical information available by consensus of two readers and off-site by two independent blinded readers at two different centers. Comparison of pre and post contrast scans and of the different readers was performed. Reference examinations were histology, intraoperative US, MRI or CT.

Results

Sensitivity for malignancy improved from 81/89/66% (on-site/off-site reader 1/2) before to 100/96/96% post contrast administration (p < 0.05, except for reader 1). Specificity improved from 48/48/54% on baseline US to 89/80/76% on CEUS (p < 0.05). Accuracy for specific lesion diagnosis was 62/59/50% pre and 90/77/72% post contrast (p < 0.05). Classification and characterisation post contrast were mildly inferior for off-site reading. Agreement between on-site and off-site readers of unenhanced scans was fair (κ = 0.29–0.39) while it was good for CEUS (κ = 0.63–0.79).

Conclusions

CEUS improves classification and characterisation of focal liver lesions and interobserver agreement compared to conventional US. Classification and characterisation post contrast were mildly but statistically significantly better for on-site than for off-site reading.  相似文献   

15.

Objective

To evaluate agreement between contrast-enhanced ultrasound (CEUS), multi-detector row computed tomography (MDCT) and magnetic resonance imaging (MRI) for the assessment of typical and atypical enhancement patterns of small hepatocellular carcinoma (HCC); and to compare diagnostic sensitivity of 2005 and 2010 American Association for the Study of Liver Diseases (AASLD) guidelines.

Materials and methods

Between January 2008 and December 2009, we included cirrhotic patients with newly diagnosed 10–20 mm HCC imaged at two contrast-enhanced imaging techniques among CEUS, MDCT, and MRI. Dynamic studies were reviewed by two radiologists to assess enhancement pattern. Percentage of cases with concordant findings and Cohen coefficient (k) were calculated. McNemar's test was used to compare sensitivity between 2005 and 2010 AASLD guidelines.

Results

There were 91 patients (69 M; 22 F; mean age, 68 years) with 96 HCCs, studied with a combination of CEUS and MDCT (n = 59), CEUS and MRI (n = 26), or MDCT and MRI (n = 11). Intermodality agreement for assessment of tumor enhancement pattern was 67% (k = 0.294, P = 0.001). Typical enhancement pattern was detected coincidentally at two imaging modalities in 50 (52%) HCCs. Sensitivity for the diagnosis of HCC increased significantly using the 2010 AASLD (81/96 (84%) vs. 50/96 (52%), P < 0.001).

Conclusions

Agreement between two imaging modalities for the detection of typical tumor enhancement pattern was reached in 52% of cases. The 2010 AASLD guidelines significantly increased the sensitivity for the diagnosis of HCC.  相似文献   

16.

Purpose

The purpose of this study was to evaluate the accuracy of T-staging of gastric cancer by air-filling multidetector-row CT (air-MDCT) compared with water-filling MDCT (hydro-MDCT).

Materials and methods

One hundred fifteen patients with histologically diagnosed gastric cancer were included in this study. Fifty-eight patients underwent air-MDCT, and the remaining 57 had hydro-MDCT using a 64-channel scanner. Based on the volumetric data of contrast-enhanced MDCT obtained about 75 s after intravenously injecting 525 mg iodine per kilogram patients weight (525 mgI/kg) nonionic contrast material at the rate of 2 ml/s, oblique coronal and oblique sagittal multi-planar reformatted images perpendicular to the stomach wall, including the tumor, were reconstructed on a workstation. Mural invasion of gastric cancer into the gastric wall, as visualized by CT, was classified according to the TNM classification, and the results of T-staging by MDCT were compared with those by pathologic analysis after surgery.

Results

Correct assessment of T-staging by air-CT was achieved in 48 of 58 patients (83%), and that by hydro-MDCT was 49 of 57 patients (86%). The sensitivity, specificity, and accuracy of the technique in determining the invasion of serosa were 88%, 93%, and 91% for air-CT and 83%, 95%, and 91% for hydro-CT. There were no significant differences between hydro-MDCT and air-MDCT in sensitivity (P = 0.73), specificity (P = 0.71) and accuracy (P = 0.98).

Conclusion

Air-MDCT is a very valuable tool in T-staging of gastric cancer as well as hydro-MDCT.  相似文献   

17.

Objective

To asses the value of second-look ultrasound (US) for identifying BIRADS 3 (Breast Imaging Reporting Data System) mammary lesions detected by breast Magnetic Resonance imaging (MRI).

Materials and methods

From April 2008 to May 2009 330 breast MRI were performed of which 60 patients are classified as BIRADS 3. 84 lesions underwent second-look US and percutaneous vacuum biopsy Vacora system US-guided. Statistical analysis: lesions were stratified into two groups: visible on US (Group 1) and not visible on US (Group 2).The clinical impact of second-look US was studied in terms of negative predictive value (NPV).

Results

The positive predictive value (PPV) of category 3 BIRADS MRI was found to be 89%. Second look-US results detected lesions in 51% of the MRI enhancing lesions. The second look-US showed a NPV of 97%. The NPV of second look-US was significantly greater than the NPV of MRI BIRADS 3 (97% vs 89%, p < 0.05). The logistic regression analysis showed a higher number of malignant lesions in group 1 than in group 2 (7vs 2, OR 3.7, p < 0.05).

Conclusions

The second-look US permitted the correct management of subcentimetric MRI BIRADS 3 lesions not visible with conventional imaging tecniques.  相似文献   

18.

Objectives

To evaluate feasibility, accuracy and reproducibility of combined US-MR of the breast using volume navigation technique.

Subjects and methods

Five healthy females underwent bilateral contrast-enhanced MR (CE-MR) of the breast in supine position, after positioning three couples of markers on the breast. After CE-MR data uploading in the ultrasound (US) database, manual co-registration was obtained during live US of the breast by means of an electromagnetic transmitter positioned near the subject under examination and two electromagnetic sensors were mounted on the transducer bracket. Transmitter and sensors were connected to a position-sensing unit embedded in the US equipment allowing to track probe position and orientation within the electromagnetic field. Live US image were co-registered to the previously loaded breast CE-MR volume by coupling markers. For each subject, two independent radiologists recorded the examination time and verified twice image alignment using five fixed checkpoints. Pair t Student test and Wilcoxon test were used for statistical analysis.

Results

In all subjects US and CE-MR images were successfully combined. The examination time was 10 ± 2 vs. 9 ± 4 min, respectively (p = 0.642; NS). A total of one hundred measurements of images misalignment were performed: the measurements recorded between the two operators were 0.42 ± 0.32 cm and 0.58 ± 0.41 cm (p = 0.161; NS), and 0.50 ± 0.32 cm and 0.56 ± 0.52 cm (p = 0.928; NS), respectively.

Discussion

In our preliminary experience, volume navigation technique appears to be a accurate and reproducible method to combine CE-MR image during unilateral US of the breast.  相似文献   

19.

Purpose

To study the radiological appearance and pathological features of breast phyllodes tumors (PTs), and to enhance the recognition of the tumor.

Materials and methods

Clinical and imaging findings were retrospectively reviewed in 24 women with PTs confirmed by surgical pathology. All of the 24 patients had preoperative MRI and sonography, and 10 had preoperative mammography.

Results

The histologic findings were benign, borderline and malignant PTs in 16.7% (4/24), 45.8% (11/24) and 37.5% (9/24) of cases, respectively. The tumor size (p = 0.001), irregular shape on sonographic imaging (p = 0.039), internal non-enhanced septations (p = 0.009), silt-like changes in enhanced images (p = 0.006) and signal changes from T2-weighted to enhanced images on MRI (p = 0.001) correlated significantly with the histologic grade; the BI-RADS category of the MRI could reflect the PT's histologic grade with a correlation coefficient of 0.440 (p = 0.031). If the category BI-RADS ≥4a was considered to be a suspicious malignant lesion, the diagnostic accuracy of mammography, US and MRI would be 70% (7/10), 62.5% (15/24) and 95.8% (23/24), respectively.

Conclusion

The tumor size and several US and MRI findings can be used to help preoperatively determine the histologic grade of breast PTs. When a patient presents with a progressively enlarging, painless breast mass, MRI should be recommended first.  相似文献   

20.

Purpose

To investigate the imaging features of portal biliopathy with emphasis on MR cholangiopancreatography (MRCP). The ancillary vascular findings of portal biliopathy were also evaluated by accompanying MR portography, dynamic contrast-enhanced (CE) CT, and dynamic CE MRI studies.

Materials and methods

Sixteen patients with portal cavernoma were included in the study. Patients had undergone MRCP (n = 16) studies accompanied by MR portography (n = 13), dynamic CE CT (n = 3) or dynamic CE MRI (n = 2) of the liver. Two patients had undergone both dynamic CE CT and dynamic CE MRI. Two radiologists evaluated all the examinations together, retrospectively. MRCP images were analyzed for the presence of biliary stenosis, upstream (prestenotic) dilatation, wavy appearance of the bile ducts, angulation of the common bile duct (CBD), and choledocholithiasis. MR portography, dynamic CE CT and dynamic CE MRI studies were evaluated for the existence of portal cavernomas, and the presence of gall bladder/choledochal varices.

Results

All patients had signs of portal biliopathy on MRCP. Frequencies of the biliary findings on MRCP were as follows: biliary stenosis, 93.7%; upstream dilatation, 68.7%; wavy appearance of the biliary tree, 87.5%; angulation of the CBD, 75%. None of the patients had choledocholithiasis. Frequencies of the ancillary vascular findings detected on CE studies were as follows: gall bladder varices, 100%, choledochal varices, 93.7%.

Conclusion

MRCP features of portal biliopathy in order to their frequencies were as follows: biliary stenosis, wavy appearance of the bile ducts, angulation of the CBD, and upstream dilatation of the bile ducts.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号