首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
目的:总结国内外全髋关节置换术后股骨假体周围骨密度变化的研究,为全髋关节置换术后假体周围骨溶解的早期发现提供依据。资料来源:检索Medline1980-01/2006-04和Embase1980-10/2006-08期间的相关文章,检索词"Total Hip Arthroplasty,bone loss",并限定文章语言种类为English。同时检索万方数据库1990-01/2001-04期间的相关文章,限定文章语言种类为中文,检索词"全髋置换术,假体周围,骨密度"。资料选择:纳入标准是与全髋置换术后假体周围骨密度相关的文章,以临床研究类文章为主,同时包括综述性文章。资料提炼:共收集相关文献56篇,按上述标准纳入30篇,其余文献均被排除。资料综合:全髋置换术股骨假体有两种固定方式:骨水泥固定型与非骨水泥固定型。两种类型虽然固定方式不同,但术后假体周围均存在骨量丢失,应用双能X线吸收测定法能够早期检测出假体周围骨量的丢失。结论:双能X线吸收测定法逐渐成为定量监测假体周围骨量丢失的重要手段,术后连续性检测假体周围骨密度对于早期发现假体松动有重要意义。  相似文献   

2.
目的系统回顾以往基于髋关节正位X线片测量髋臼假体方位的方法,提出更加可靠的测量工具。方法利用Matlab软件建立基于髋关节正位X线片拟合臼杯开口椭圆的新方法,并测量34例全髋关节置换术后臼杯的前倾角和倾斜角。由4名骨科医生完成信度实验,评价该测量方法的观察者间及观察者内信度。结果椭圆二次导数函数图可知,椭圆切线斜率的变化率在长短轴附近最小,距离长短轴端点越近,所选拟合点对拟合椭圆形态的影响也最小。观察者内信度表明:前倾角和倾斜角的组内相关系数ICC分别为0.916(95% CI:0.858~0.954)和0.948(95% CI:0.910~0.972)。观察者间信度结果为:前倾角和倾斜角的组间相关系数ICC分别为0.893(95% CI:0.821~0.941)和0.937(95% CI:0.892~0.966)。结论基于椭圆导数理论,本研究提出了一种基于髋关节正位X线片测量髋臼假体方位的新方法,可以用于临床评价全髋关节置换术后的假体位置。  相似文献   

3.
上海地区2591例双能X线骨密度测量分析   总被引:1,自引:0,他引:1  
目的分析骨密度(BMD)及骨质疏松(OP)患病变化规律。方法采用双能X线骨密度仪检测上海地区2591例桡骨远端1/3BMD,年龄范围20~80岁。按5岁一个年龄组进行统计分析。结果男、女BMD峰值均分布在35~39岁年龄组。BMD随年龄增加逐渐下降,同龄男性BMD大于女性。OP患病率随年龄增加而上升。结论OP常见发病年龄在中年之后,呈进行性病变,在老年人更常见。  相似文献   

4.
目的 探讨早期负重锻炼对全髋关节置换术后假体周围骨密度的影响.方法 选取住院行全髋关节置换术治疗的患者42例,随机分为对照组和观察组,每组21例.对照组进行常规治疗和护理,观察组在对照组的基础上术后1 w进行负重锻炼.观察两组患者术前及术后3、6、12及24个月的假体周围骨密度及Harris评分情况.结果 观察组术后3、6、12个月的假体周围骨密度均高于对照组(均P<0.05),而Harris评分优良率高于对照组(P<0.05).结论 早期负重锻炼对全髋关节置换术后假体周围骨密度的影响较佳,可促进机体的早期功能恢复.  相似文献   

5.
目的 探讨髋关节置换术后假体脱位的护理方法.方法 对30例髋关节置换术假体脱位患者的临床资料及护理进行回顾性分析.结果 30例患者术后患肢功能恢复良好,平均住院时间15.4 d.发生假体脱位2例,其中1例于术后第3天脱位,1例出院后脱位,均为遵医行为差所致,经及时给予手法复位、皮牵引4周,均能进行日常生活.结论 术前进行护理指导、术后正确搬动患者、保持正确的体位、恰当的功能锻炼及出院指导,是预防髋关节置换术后假体脱位、提高手术成功率的重要措施.  相似文献   

6.
目的:观察双侧股骨近端相应部位骨矿密度的差异性,探讨双能X射线吸收法测量双侧股骨近端的诊断价值。方法:选择2001-11/2005-12在暨南大学附属第一医院进行骨密度测量的广州地区受试者1055例(女性组789例、男性组266例)。①所有受试者进行了双侧股骨近端(股骨颈、股骨转子区、股骨颈上部和整体髋关节)双能X射线吸收法骨密度测量,比较双侧股骨近端骨密度。②从受试者中筛选出绝经后妇女500例,按照世界卫生组织1994年制定的方案,依据双侧股骨近端各测量部位的最低T值进行诊断,比较双侧股骨近端骨密度测量结果在诊断水平上可造成的差异。③从受试者中随机选取30例(男8例,女22例,年龄21~72岁,平均42.1岁)同时进行了两次骨密度测量,计算各测量部位的精密度和最小显著变化值。结果:①女性组和男性组双侧股骨近端各测量部位骨密度值呈高度正相关(r=0.88~0.97,P<0.001)。男性组各部位骨密度值双侧差异均不显著;女性组中整体髋关节的骨密度值存在较小的但有统计学意义的差异(骨密度差值=0.030g/cm2,t=2.387,P=0.017),右侧高于左侧。②在500例绝经后妇女中,左右侧股骨近端结果一致者83.2%(416/500),84例(16.8%)双侧测量结果可产生不一致的诊断。经精密度校正后7.0%(35/500)双侧测量结果可产生不一致的诊断。③股骨近端不同部位的单侧测量精密度在0.7%~2.2%,而相应部位的双侧测量精密度在0.6%~1.2%。双侧测量精密度比单侧测量提高20%~45%。结论:①广州地区女性股骨近端的骨密度值存在较小的但有统计学意义的差异。②双侧测量精密度比单侧测量提高,有助于监测骨矿物质密度变化。③有部分的个体双侧测量会改变单侧测量的诊断结果,单侧测量存在有漏诊的可能性。  相似文献   

7.
目的:探讨人工髋关节置换术后假体松动的原因,总结围术期护理干预的方法。方法:选取2006年1月~2012年1月人工髋关节置换术后发生假体松动患者45例,针对发生的原因进行相关分析,采取心理护理、疼痛管理、肢体康复锻炼、生活指导及并发症防治等护理干预方法。结果:45例患者中44例按照指定的康复治疗和训练方法进行功能锻炼,髋关节术后功能恢复良好,无脱位、感染发生,仅1例患者出现下肢深静脉血栓。结论:针对人工髋关节置换术后假体松动原因,并根据手术的不同采取围术期护理干预,能有效恢复髋关节功能,防止术后并发症的发生,提高患者手术满意度。  相似文献   

8.
目的评价SPECT/CT图像融合技术在髋关节置换术后假体松动诊断中的价值。方法行人工髋关节翻修术患者45例(45髋),术前均行SPECT/CT检查,观察SPECT/CT术前诊断假体松动的敏感性、特异性、准确性。结果SPECT/CT图像融合技术诊断髋关节置换术后假体松动的敏感性为91.9%(34/37),特异性为37.5%(3/8),符合率为82.2%(37/45)。结论 SPECT/CT图像融合技术可作为髋关节置换术后假体松动诊断的重要影像学依据。  相似文献   

9.
归纳了全髋关节置换术后假体脱位的原因、观察、综述了预防假体脱位护理的研究主要进展。  相似文献   

10.
人工髋关节置换术后假体周围骨质丢失的分析   总被引:1,自引:0,他引:1  
目的 观察人工髋关节置换术(THA)后随时间推移假体周围骨密度和溶骨的改变情况及THA术后假体松动和骨重建的时间,分析假体周围骨量丢失的原因及相关影响因素。方法 THA术后患者83例,对比观察THA术侧髋关节和健侧髋关节,同时按固定方式分为骨水泥组和非骨水泥组。应用双能X线骨密度仪测量各组THA术后股骨柄假体及髋臼假体周围的骨密度。结果 不论是骨水泥固定还是非骨水泥固定,髋臼周围骨密度在1年以内和7年以后下降明显,4~7年没有明显变化。同时,骨水泥固定方式髋臼周围骨质丢失的情况比非骨水泥组出现的时间早而且范围广。结论 髋臼假体底周的骨质丢失较股骨柄假体更早、更快、更严重,尤其在髋臼的负重区。其改变的时相规律为:THA术后1年之内骨密度下降明显,4~7年内相对稳定,7年后骨丢失呈持续性日趋下降的趋势。采用髋臼假体用非骨水泥、股骨柄假体用骨水泥固定这种混合型固定方式有利于防止髋臼假体底周的骨质丢失。  相似文献   

11.
目的:研究绝经前全子宫切除保留单侧卵巢术对女性骨密度的影响。方法:对50例全子宫切除保留单侧卵巢术患者和60例年龄相近的自然绝经妇女用双能X线骨密度仪测定骨密度,进行比较及相关回归分析。结果:全子宫切除保留单侧卵巢术患者的骨密度明显低于对照组,手术组各部位骨密度值与术后停经时间呈密切负相关,其中股骨各部骨密度值较腰椎与停经时间负相关性更大。结论:全子宫切除保留单侧卵巢术可造成骨密度下降,进行手术时的年龄对骨密度值低下无影响,而术后停经时间的长短与骨密度值低下有关。  相似文献   

12.
背景:陶瓷对陶瓷界面的人工髋关节假体置换手术目前在临床上广泛开展,但是越来越多的报道显示全陶关节置换术后有些患者会出现髋关节异响,影响患者的手术满意度,严重者甚至患者的生活质量. 目的:综述目前国内外对髋关节异响问题的研究现状,阐明髋关节置换后异响的发生率和危险因素,探究髋关节异响产生的机制和临床防治路径. 方法:由第一作者检索1972年1月至2012年12月PubMed数据库,在标题和摘要中以“total hip arthroplasy,hip squeaking,hip noise”为主题词进行检索有关髋关节异响危险因素及形成原因和机制等方面的相关文献. 结果与结论:异响声在陶瓷对陶瓷界面中和金属对金属界面中都会发生,发生率报道不一.引起全髋关节置换后异响声的原因包括患者因素、手术因素和假体因素,它们间互为因果,相互影响.目前的研究认为异响产生的机制包括边缘负荷,斑纹磨损,假体撞击,第三体颗粒和润滑缺失等.髋关节置换后异响是多因素作用下产生的界面异常摩擦,从而造成假体振动产生异响.大多数患者只需临床随访,少部分患者需要手术干预.  相似文献   

13.
背景:目前陶瓷制造工艺方面仍在不断改进,陶瓷对陶瓷摩擦界面的假体成为关节外科领域关注的焦点,并取得了良好的临床疗效,然而随着陶瓷对陶瓷摩擦界面假体的广泛应用,出现了假体碎裂和高调摩擦音等一系列问题. 目的:探讨陶瓷对陶瓷全髋关节置换的初期临床疗效. 方法:对常熟市第一人民医院2006年1月至2010年6月间小于55岁行陶瓷对陶瓷全髋关节置换的50例患者进行随访,其中男19例(20髋),女31例(33髋),平均年龄45岁,随访时间平均20(12-42)个月.置换前后均采用 Harris 评分进行疗效评估,影像学随访包括髋臼假体外展角和前倾角,假体松动采用 Kawamura 及 Engh 标准,骨溶解采用 Engh 标准,异位骨化依据 Brooker 法评价. 结果与结论:置换前 Harris 评分为(48.10±26.33)分,置换后为(91.10±19.78)分.置换后随访无患者有关节异响的主诉,未见假体松动,未发生假体周围感染,无可观察到的磨损和骨溶解,无明显异位骨化.其中,1例因髋臼陶瓷内衬碎裂翻修.可见陶瓷对陶瓷全髋关节置换对于年轻的骨质量较好的患者短期疗效显著,长期疗效有待于进一步随访.  相似文献   

14.
This cross-sectional study provides values for lumbar spine bone mineral content (BMC) and density (BMD) in 41 healthy full-term born Finnish infants, 19 boys and 22 girls, during the first year of life measured by dual energy X-ray absorptiometry (DXA) using the Lunar DPX densitometer. Lumbar BMC correlated with the weight (r=0.733; P=0.000), length (r=0.677; P=0.000), standardized length (r=0.315; r=0.045) and age at examination (r=0.314; P=0.045), and with the bone area (r=0.736; P=0.000). Infants with < or =-1 SD scores for lengths at examination had significantly lower BMC values [mean (SD); 1.79 (0.66) g] than infants with SD scores above -1 SD [2.27 (0.46) g] (P=0.011). Exclusive breast feeding did not correlate with the lumbar BMC values (r=-0.039; P=0.811). No differences were found in lumbar spine BMC (P=0.097), BMD (P=0.254) and bone area (P=0.094) values between boys and girls. In order to determine the predictive value of the anthropometric measurements on lumbar BMC, stepwise multiple regression analysis were performed, bone area and present weight were the only independent variables which explained 67.6% of the variance in the BMC values. The present cross-sectional data imply that, in healthy term infants, patterns of relative linear growth during the first year of life are related to the lumbar BMC values. In future, careful longitudinal measurements of linear growth are needed to study connections between growth patterns and bone mineral status in infancy.  相似文献   

15.
背景:Ribbed解剖型生物固定柄设计符合股骨生物力学特性,具有初始稳定性好、骨长入快及应力遮挡低等优点,获得满意的临床疗效。 目的:探讨Ribbed解剖型生物固定股骨柄假体(Ribbed柄)的设计特征及其与临床疗效的关系。〈br〉 方法:对2010年3月至2012年3月因髋关节疾病采用Ribbed柄行全髋关节置换的患者进行回顾性分析。共获完整资料者52例(52髋),男20例,女32例;置换时年龄22-78岁,平均59岁。随访时间2-4年。评估置换前后Harris评分、置换后大腿疼痛率、术中骨折发生率、切口愈合情况、脱位及翻修等。影像学重点评估股骨柄髓腔充填率、股骨柄假体下沉、假体周围放射学透亮线、骨长入、应力遮挡及骨溶解等。 结果与结论:术中股骨骨折发生率为6%;所有切口均一期愈合;无髋关节脱位及翻修病例;大腿疼痛率为6%,均于置换后1年消失;末次随访时,平均Harris评分由置换前48分提高到末次随访时96分。置换后X射线片示所有患者股骨髓腔充填满意,平均充填率:正位片上干骺端、中段和远端分别为91%,88%和86%,侧位片上干骺端、中段和远端分别为88%,85%和81%;末次随访时,49髋(92%)为稳定性骨长入固定,3髋为稳定性纤维长入固定,股骨侧及髋臼侧假体周围均未见骨溶解;5髋(10%)发生股骨柄假体下沉,但均小于2 mm;所有患者均出现不同程度的应力遮挡现象,其中1度31髋、2度19髋、3度2髋,无4度应力遮挡发生。提示Ribbed柄设计符合生物学固定要求,具有初始稳定性好、骨长入快及应力遮挡低等优点,可获得满意的临床疗效。  相似文献   

16.
背景:随着人工髋关节置换的广泛应用以及相关研究的深入,更多继发性股骨假体周围骨折被报道。目的:探讨人工髋关节置换后发生股骨假体周围骨折的原因、预防措施及骨折的分型治疗方法。方法:回顾性研究人工髋关节置换后发生的股骨假体周围骨折的分型、治疗方法及相应临床疗效的临床资料,对相关文献资料趋势进行多层次探讨,依据Vancouver分型标准,分析各类型骨折及各种治疗方式的结果与并发症,明确不同骨折类型的治疗方法,建立客观有效的评估标准,为临床治疗提供参考。结果与结论:人工髋关节置换后股骨假体周围骨折的与患者的年龄、基础疾病、骨质疏松和假体类型的选择等因素密切相关,Vancouver 分型标准及治疗方案对临床治疗有指导意义,根据不同分型采用不同的治疗方法以促进骨折愈合,人工髋关节置换后股骨假体周围骨折的治疗方法多采用形状记忆合金环抱器、微创内固定系统、锁定加压钢板、异体皮质骨板、碳纤维板、打压植骨及翻修等固定,实际应用中常会有几种方式结合运用,对于B2和B3型骨折患者,应注意骨折周围、髓腔内外充分植骨。  相似文献   

17.
背景:股骨偏心距的重建对于恢复外展肌力和髋关节周围软组织张力平衡,维持关节稳定,恢复关节功能,减少置换后跛行,降低假体磨损、人工关节脱位等并发症的发生率具有重要意义。 目的:探讨全髋置换的重建偏心距对髋关节功能恢复的影响。 方法:对比分析采用组配式假体(S-ROM)行全髋置换20例20髋患者及采用普通假体(Corail)行全髋置换19例20髋患者的相关资料,通过临床(Harris评分)和X射线测量,对两组患者置换后髋关节功能和偏心距重建率进行对比研究。 结果与结论:纳入患者均无感染、骨折、脱位,无深静脉血栓及神经损伤等并发症。临床随访:在组配式假体和普通假体两组中,股骨偏心距重建组与未重建组置换前Harris评分差异无显著性意义(P 〉 0.05);置换后12个月及末次随访偏心距重建患者Harris评分高于未重建者(P 〈 0.05)。髋关节外展活动度大于未重建患者(P 〈 0.05)。X射线随访:组配式假体和普通假体两组中股骨偏心距重建率差异有显著性意义 (χ2=3.956,P 〈 0.05),39髋(98%)股骨假体位于中立位,1髋(2.5%)轻度外翻位,两组中股骨偏心距得到重建与未得到重建患者的髋臼假体外展角及前倾角差异均无显著性意义(P 〉 0.05)。说明组配式假体和普通假体两组中股骨偏心距得到重建患者的髋关节功能和髋关节外展活动度优于未得到重建者,组配式假体偏心距重建率高。  相似文献   

18.
19.
目的探讨不同时期脊柱滑脱症患者的骨密度变化规律。方法对105例腰椎滑脱症患者的腰椎骨密度进行测量,依据不同的滑脱分型,进行结果对比分析。结果腰椎滑脱症患者平均骨密度较同年龄组正常值偏低。随病程的延长和年龄的增长,腰椎滑脱症患者骨密度均降低(P<0.01);骨质疏松组假性滑脱发生率明显高于非骨质疏松组(P<0.01);骨质疏松组发病部位以L5滑脱多见,非骨质疏松组发病部位以L4、L5滑脱为主(P<0.05)。结论骨质疏松症与腰椎滑脱有一定因果关系,两者互相影响,脊柱滑脱患者要防止骨质疏松症的发生,预防骨质疏松症将有助于防止假性脊柱滑脱的发生。  相似文献   

20.
Objective. To test mechanical bone quality and bone mineral density of the femoral head at the day of implantation as indicators for femoral prosthesis loosening.

Methods. Mechanical bone quality of a femoral head slice was assessed by destructive compression testing combined with bone mineral density measurements using peripheral quantitative computed tomography. Fourteen patients with walking pains were attainable for a radiographical follow-up mean 7.1 years after implantation.

Results. Radiolucent lines along the stem were evident in 11 of 14 femurs, most of them seen in Gruen zones 7, 6, 1, 3, 14, and showed strong correlations to preoperative bone strength (r=−0.80; P<0.001) and axial stiffness (r=−0.75; P=0.002), yet not to bone mineral density (r=−0.67; P=0.009). Slight varus deviations <3° were noted in six femurs. Preoperative strength was reduced in this femurs to 54% (P=0.006), and stiffness to 61% (P=0.038), while bone mineral density did not differ significantly.

Conclusions. Femoral prosthesis loosening after seven years can be predicted by mechanical bone quality of the femoral head at the time of implantation. Bone mineral density measurements may also indicate future stem loosening but have to interpreted carefully, keeping in mind a poorer predictive value.

Relevance Indications and choice of type of hip arthroplasty should be balanced in osteoporotic bones in particular. While preoperative bone mineral density measurement allows the prediction of mechanical bone quality, its relevance in predicting failure in arthroplasty treatment remains unclear.  相似文献   