1.
Appropriately timed noncompetitive ventricular pacing potentially may initiate ventricular tachycardia in patients prone to these arrhythmias. The combination of bradycardia pacing and stored electrograms in a currently available cardioverter defibrillator provides an opportunity to evaluate the occurrence of such pacing induced ventricular tachycardia. During a surveillance period of 18.7 ± 11.4 months, stored electrograms documented 302 episodes of ventricular tachycardia in 77 patients. Five patients (6.5%) demonstrated 25 episodes (1–16 per patient) of ventricular tachycardia that were immediately preceded by an appropriately paced ventricular beat (8.3% of all episodes of ventricular tachycardia). All five patients had prior myocardial infarctions and a history of monomorphic ventricular tachycardia occurring both spontaneously and in response to programmed electrical stimulation. Antitachycardia pacing terminated pacing induced ventricular tachycardia in 22 episodes; in one episode antitachycardia pacing accelerated ventricular tachycardia. In two cases shock therapy was aborted for nonsustained ventricular tachycardia. We conclude that, in selected postinfarction patients with recurrent sustained monomorphic ventricular tachycardia treated with implantable cardioverter defibrillators, appropriately timed ventricular pacing may induce ventricular tachycardia.  相似文献   

2.
Ventricular tachycardias can be terminated by a variety of pacemaker techniques, including rapid and slow stimulation. Fast tachycardias are typically poorly tolerated, and require prompt intervention, usually with rapid pacing. Termination of ventricular tachycardia by slow or single capture pacemaker stimulation techniques is attractive, because of its presumed safety and the possibility of using simple implantable pacers. To identify factors favoring termination, single capture stimulation was used in 390 episodes of ventricular tachycardia in 21 patients, 16 with coronary artery disease, able to tolerate ventricular tachycardia forseveral minutes. Single capture stimulation terminated 223 episodes (57%) in 18 patients, and two were accelerated. Of 157 episodes exposed to 2–3 programmed extrastimuli or rapid pacing 149 (94%) were terminated and 7 were accelerated. Direct current cardioversion was needed in 12 episodes. Without medications, only two patients tolerated VT. Only one patient had reliable termination with single capture stimulation over several days. Systolic blood pressure was similar in episodes terminated and not terminated by single capture stimulation, but the ventricular rate was significantly lower in episodes terminated, 116 ± 19 vs. 133 ±24 (p<0.001). Termination of ventricular tachycardia was not affected by QRS morphology. Single capture termination of ventricular tachycardia is largely unpredictable, with limited reproducibility over a period of time. Although comparatively safe, single capture techniques are not likely toprove useful in the long-term treatment of many patients with recurrent ventricular tachycardia.  相似文献   

3.
4.
The purpose of this study was to investigate the efficacy and safety of antitachycardia pacing (ATP) in third-generation implantable Cardioverter defibrillators (ICDs) for terminating spontaneously occurring ventricular tachycardias (VTs) in patients with severely depressed left ventricular (LV) function. Ninety-one patients with active ATP were followed for 16 ± 13 months. During this period, 775 VT episodes occurring in 36 patients were treated by ATP. The patients were divided into two groups according to their LV ejection fraction (LVEF): group A with LVEF ± 30% (n = 20), and group B with LVEF ± 30% (n = 16). There were no differences between both groups in age, gender, underlying heart disease, indication for ICD therapy, or drug therapy. The VT rates were comparable (group A: 183 ± 16 beats/min; group B: 180 ± 21 beats/min; P = NS). Eighty-three percent of all episodes (n = 332) in group A and 93% of the VTs (n = 443) in group B were ATP terminated (P ± 0.01). Ten percent of VTs in group A were accelerated by ATP into the ventricular fibrillation zone versus 2% in group B (P ± 0.01). The individual termination rate and acceleration rate per patient were comparable in both groups. All VT episodes unresponsive to ATP were converted by backup shocks. The efficacy of first-shock therapy was similar in both groups (group A: 89%; group B: 97%; P = NS). The proportion of patients who needed at least one backup shock for unsuccessful ATP was comparable in both groups (group A: 65%; group B: 56%; P= NS). We conclude that ATP is effective and safe in patients with recurrent VTs and severely depressed LV function, and it can be safely programmed in this group of patients to minimize the use of shock therapy.  相似文献   

5.
Pacing for Ventricular Tachycardia   总被引:1,自引:0,他引:1  
Plusieurs problèmes restent à résoudre avant que les stimulateurs puissent jouer un rôle majeur dans le traitement de la tachycardie ventriculaire. Nous citons des exemples pour illustrer quelques difficultés à résoudre. les mécanismes qui contribuent au succès ou à l'échec de la stimulation antitachycardie sont discutés. L'avenir de cette stimulation sera plus assuré dès que ces appareils serent équipés d'un cardioverteur-défibrillateur de secours.  相似文献   

6.
Newer ICDs provide antitachycardia (ATP) and bradycardia pacing and cardioversion and defibrillaiion shocks based on sensed interval criteria. The objectives of this investigation were to determine the algorithm related errors in tachycardia confirmation and rate classification that occurred in patients with a third-generation, noncommitted, tiered ICD therapy. Forty-three consecutive patients with the Guardian ATP 4210 ICD, which uses an X out of Y sensed interval counting algorithm for tachycardia detection, confirmation, and classification were studied. Surface ECGs, intracardiac electrograms, stored data logs, and sense histories were reviewed to diagnose errors due to these algorithms that resulted in delivery of inappropriate therapy or inhibition of appropriate therapy. Sixty-eight classification or confirmation algorithm errors from 7,610 tachycardia detections (< 1 %) were diagnosed in 23 (53%) of 43 patients. Three types of errors not related to device or sensing lead malfunction or programming mistakes were seen. In 26 episodes, the confirmation algorithm failed to detect late tachycardia reversion of nonsustained tachyarrhythmias, on the last or next to last sensed interval, and did not inhibit ATP (n = 17) or shocks (n = 9). In 28 episodes, inaccurate classification of tachycardia rate resulted in inappropriate ATP (n = 23) or shock (n = 5) therapy. In 14 episodes, the posttherapy reconfirmation algorithm produced inhibition of VVI pacing and prolonged asystole following shock therapy. These errors in tachycardia confirmation and rate classification were due to the inherent limitations of the X out of Y counting algorithm.  相似文献   

7.
Background: With the development of left ventricular pacing for cardiac resynchronization, there is an interest in the possibility of improving ventricular antitachycardia pacing (ATP) efficacy by pacing from the LV electrode(s).
Objective: This study assessed the efficacy of pacing delivered from the left coronary vein (LCV) compared to that delivered from the right ventricular apex (RVA) upon ventricular tachycardia (VT) induction and termination.
Methods: Sixty patients undergoing provocative ventricular electrophysiology (EP) studies in three centers were enrolled. Multipolar EP catheters were placed in the atrium, the RVA, and LCV. VT induction was attempted from the RVA and LCV in random order. Upon detection of monomorphic VT, burst ATP for up to 10 pulses at 88% VT cycle length was delivered from the RVA or LCV, in a random order, and crossed over when possible. Identical VT morphologies were reinduced to allow paired comparison of RVA versus LCV ATP.
Results: Data from 55 patients were analyzed. Thirty-four morphologically distinct monomorphic VT types were induced in 22 patients. ATP succeeded in 18 (55%) and VTs in 13 patients. RVA ATP terminated 15 of 23 (65%) VTs, and LCV ATP terminated 10 of 23 (43%) VTs (P = 0.14). ATP delivered ipsilateral to the earliest activation site required 5.0 ± 2.6 pulses to terminate compared to 4.8 ± 1.7 pulses when delivered from the contralateral site (P = 0.90). Paired comparison was possible for 13 VT morphologies in 11 patients. Paired RVA and LCV ATP efficacy was identical (54 % vs 54%, P = 1.0).
Conclusion: ATP delivered from a LCV lead offers no efficacy advantage over pacing from the RVA. (PACE 2010; 27–32)  相似文献   

8.
The initial experience from electrophysiological studies showed that pacing induced termination of ventricular tachycardias is usually possible but requires a critical pacing sequence. Studies on the resetting phenomenon showed, in most instances of failure of termination, that the "limiting factor" to produce ventricular tachycardia termination is usually failure to produce block within the circuit rather than failure to access or interact with the ventricular tachycardia origin. The resetting response is related to tachycardia termination in a number of ways. Of note is that a steeply increasing resetting pattern usually predicts tachycardia termination. Between 50% and 90% of induced ventricular tachycardias will be terminated by trains of rapid ventricular pacing. The analysis of the pacing rate necessary for termination shows that it varies widely. Paced cycle lengths of < 80% of tachycardia cycle length are necessary in at least 20% of tachycardias. In contrast, the incidence of acceleration is closely related to the paced cycle length: it is negligible with paced cycle lengths over 80% of tachycardia cycle length and increases to 36% with paced cycle lengths below 76% of tachycardia cycle length. Present information about efficacy of antitachycardia pacing in spontaneous tachycardias suggests that it is extremely effective, with over 90% success. However, it is likely that these data correspond to a selected group of tachycardias.  相似文献   

9.
10.
Antitachycardia pacing for ventricular tachycardia (VT) is associated with the possibility of fibrillating the heart; on the other hand, the frequency of VT and patient discomfort can limit treatment with the automatic implantable cardioverter/defibrillator (AICD). To contribute to the further development of a universal pacemaker, we evaluated the combined use of the antitachycardia pacemaker ("tachylog") and the AICD in five patients with recurrent VT. In the automatic mode, the "tachylog" worked as a bipolar VVI pacemaker. For antitachycardia pacing, a burst of rapid ventricular pacing was delivered at about 80% of the cycle length. During a follow-up period of 5 +/- 2 months (range, 3 to 8) two to 291 successful interventions of antitachycardia pacing were counted from diagnostic data which had been collected by the pulse generator during the course of treatment. When the antitachycardia pacemaker failed to terminate VT, the AICD was activated. In the individual case, between 0 and 41 discharges of the AICD were delivered. The high pulse energy of the AICD did not damage the antitachycardia pacemaker; no interference of the two devices was observed. Future antitachycardia systems should be more flexible with regard to detection and termination modes, combining antitachycardia pacing with back-up defibrillation.  相似文献   

11.
Background : Antitachycardia pacing (ATP) is an effective treatment of ventricular tachycardia (VT). However, persistent failure of ATP in some patients is well recognized. Methods : A method of deriving the local activation time from stored intracardiac electrograms in implantable cardioverter defibrillators is described. Using a case‐control design, the local activation times were compared between patients with persistent unsuccessful ATP with comparable controls with successful ATP. Results : The local activation times during VT in patients with failed ATP were longer at 120–180 ms compared with corresponding control patients with successful ATP (60–80 ms). The local activation time expressed as a proportion of VT cycle length in patients with failed ATP compared with patients with successful ATP were 0.40 ± 0.08 versus 0.19 ± 0.08 (P = 0.012). Conclusion : A novel method of deriving local activation time is described, and delayed local activation time may explain failure of ATP in terminating VT in some patients. (PACE 2010; 549–552)  相似文献   

12.
Guardian antitachycardia pacing (ATP) 4210 is a third generation, multi-programmable cardioverter defibrillator undergoing Phase I clinical trials. The tiered response includes ATP, low energy cardioversion or defibrillation, and bradycardia support. Extensive telemetry is available, including an episode log and details of all episode events. Five patients underwent the implantation of Guardian ATP 4210 as part of a Phase I trial at the University of Louisville. Two of the five patients had multiple VT episodes that were reverted successfully using ATP pacing (slow VT) and defibrillation (fast VT) and VF episodes, which resulted in defibrillation therapy over a follow-up period of 6 to 8 months. Four of the five patients required bradycardia support for bradyarrhythmias unassociated with ATP therapy or defibrillation and one patient required bradycardia support postdefibrillation therapy. The device design is microprocessor based and requires continuous interrogation of the microprocessor memory and checks of the validity of programmed parameters to continue its operation. When the safety check fails, the device is designed to shut down its antitachycardia and defibrillator functions. This design feature has a potential for leaving the patient unprotected if the device shuts down. Modification of this feature is required to ensure the device's long-term safety.  相似文献   

13.
The purpose of this study was to determine the termination and acceleration rates for 1 to 6 attempts of antitachycardia pacing (ATP) delivered by ICD in order to terminate spontaneously occurring VTs. Twenty-four ICD recipients with active ATP programs, including a maximum of six ATP sequences and spontaneously occurring VTs during follow-up, were investigated. During a mean follow-up of 42 ± 15 months (range, 17–63 months) 413 spontaneous VT episodes (17 ± 14; range, 1–49 per patient) resulting in appropriate ATP delivery by the ICD occurred. ATP successfully terminated 328 episodes (80 %) with a mean number of 1.6 ± 1.1 pacing sequences. Eighty episodes (19%) were accelerated by ATP and 5 (1%) were unresponsive to ATP. The ATP success decreased until the third ATP sequence (59%→ 31%→ 24%), but increased again in the fourth to sixth attempt (46%→ 46%→ 29%). The acceleration rate increased from sequence one to sequence three (8%→ 13%→ 28%), but decreased significantly in further ATP attempts (19%→ 0%→ 0%). The mean time delays until redetection or termination after 4, 5, and 6 attempts of ATP were 22 ± 5 seconds, 37 ± 2 seconds, and 41 ± 9 seconds, respectively. Nine patients (37%) used ≥3 ATP attempts during follow-up and all of them had a therapeutic benefit from it. Five out of 13 VTs (38%) treated with ≥4 attempts could ultimately be terminated by ATP. The results of this study demonstrate that the first ATP sequence is the most effective and that > 4 ATP attempts may be useful in a minority of patients. There seems to be a low risk of VT acceleration by the fourth to sixth ATP sequence. Because of the associated time delay, a high number of ATP attempts should only be programmed in patients with hemodynamically well-tolerated stable VTs.  相似文献   

14.
Primary prevention trials have demonstrated that patients with coronary disease, reduced left ventricular function, and nonsustained ventricular tachycardia (NSVT) have improved survival with implantable cardioverter defibrillator (ICD) therapy, presumably secondary to effective termination of life-threatening arrhythmias. However, stored intracardiac electrograms were not always available and specific arrhythmias leading to ICD therapy were not always known. We examined the occurrence of ICD events in 51 consecutive patients who match the described patient profile to determine the frequency of appropriate and inappropriate ICD therapy. ICD detections were noted in 18 (35%) patients during a median follow-up period of 13.1 months. Appropriate therapy for sustained ventricular tachycardia (VT)/ventricular fibrillation (VF) occurred in 11 (22%) patients, with appropriate shocks in 8 (16%) patients and appropriate antitachycardia pacing (ATP) in 4 (8%) patients. The time to first appropriate therapy occurred at a mean of 17 +/- 12 months (median 18 months, range 3-36 months). Inappropriate therapy occurred in 5 (10%) patients with inappropriate shocks in 4 patients and inappropriate ATP in 2 patients. Inappropriate therapy was delivered for supraventricular arrhythmias (SVAs) in 4 patients and for T wave oversensing in 1 patient. The reason for shock therapy was unknown in 1 patient (2%) due to ICD malfunction. The mean arrhythmia rate leading to appropriate therapy for VT/VF was 232 +/- 72 beats/min (range 181-400 beats/min), and the mean rate leading to inappropriate therapy for SVT was 168 +/- 10 beats/min (range 160-180 beats/min). Patients with coronary disease and asymptomatic NSVT commonly receive appropriate defibrillator therapy. These results support the need for ICD implantation for primary prevention, with attention to careful programming of the detection rate to prevent inappropriate therapy.  相似文献   

15.
Seventy consecutive patients received the first VENTAK PRx pulse generators (Cardiac Pacemakers, Inc.) implanted in the United States. This multiprogrammable device has therapeutic options that include: (1) antitachycardia pacing; (2) low energy cardioversion; (3) defihrillation shocks; and (4) bradycardia pacing. There were 60 males and 10 females with a mean age of 65.3 ± 9.4 years. The anatomical diagnoses were coronary artery disease in 55 patients, cardiomyopathy in 7 patients, congenital heart disease in 2 patients, and miscellaneous disease in the remaining 6 patients. Thirty-six percent had a history of sudden cardiac death and 90% had documented monomorphic ventricular tachycardia. The mean ejection fraction was 32.7%± 12.2%. Thirty-three (49.3%) had an ejection fraction ≤ 30%. Electrophysiological testing was done preimplant, predischarge, and 1 to 2 months postimplant to define a specific electrical therapy and evaluate the efficacy of the device. Two hundred ninety-three of 367 (80%) episodes of induced ventricular tachycardia were successfully terminated by the VENTAK PRx programmed for antitachycardia pacing. There were 1,794 total therapy episodes for spontaneous ventricular tachycardia; 91% (1,641 episodes) were terminated by antitachycardia pacing and 153 episodes were converted by shocks during a minimal 6-month follow-up per patient. We conclude that documentation of a successful antitachycardia pacing modality in the electrophysiology laboratory predicts conversion of spontaneous episodes of ventricular tachycardia. Furthermore, antitachycardia pacing by the VENTAK PRx can terminate the majority of episodes of ventricular tachycardia.  相似文献   

16.
The long-term efficacy of pacing for termination o/supraventricular tachycardia (SVT) and ventricular tachycardia (VT) was reviewed. Increasingly complex and sophisticated antitachycardia pacing stimulation patterns have evolved, and are outlined. Although excellent results are reported with simple patterns, it may be that the more complex algorithms increase the percentage o/tachycardia patients who may be candidates for implantation of a device. In the papers reviewed, there were 460 patients, 268 with SVT, and 192 with VT. Results were judged to be good-excellent in 96.5% of both VT and SVT groups.  相似文献   

17.
Patients with implantable defibrillators often require bradycardia pacemakers. Adverse interactions between separate defibrillator and bradycardia pacing units have occurred, including failure to detect ventricular fibrillation due to persistent bradycardia pacing during the arrhythmia. A device with combined bradycardia pacing and antitachycardia therapy capability may obviate adverse device interactions. We describe a previously unrecognized phenomenon that may occur in a combined device when the algorithms for sensing bradycardia and tachycardia are "codependent"; that is, the circuitry for brady- and tachyarrhythmia detection relies on the same automatic gain sense amplifier. Three of 37 patients in whom the device was implanted had ventricular tachycardia initiated when bradycardia pacing stimuli were delivered by the device after probable nonsensed sinus beats. In each case, nonsensed beats appeared to have a markedly diminished amplitude, occurred after ventricular premature depolarizations that produced large amplitude electrograms, and had an electrogram morphology that matched that of sinus rhythm. In each case, the bradycardia pacing interval was at least 1,200 msec (range 1,200 to 1,714 msec). In two of the three patients, large amplitude ventricular premature depolarizations or nonsustained ventricular tachycardia caused an adjustment of the gain control that potentiated the failure to sense the subsequent lower amplitude signal. In all three patients, the induced arrhythmia was rapidly terminated by pacing or cardioversion. Decreasing the bradycardia pacing interval by 110-514 msec has prevented recurrence during short-term follow-up. Our findings suggest that codependent bradycardia and antitachycardia devices may have their own unique potential difficulties in adapting to rapid changes in rate and signal amplitude.  相似文献   

18.
This study was undertaken to determine the safety and efficacy of three different pacing modalities on the termination of ventricular tachyarrhythmias. Thirty-two patients were studied in the electrophysiology laboratory. Three randomized pacing modalities were selected for attempted conversion: auto increment, auto burst, and random burst. In all three groups, arrhythmias with cycle lengths shorter than 230 ms required DC shock, with one exception. Those longer than 230 ms were terminated by pacing in 85% of cases. There was a 15% rate of acceleration. Thus, antitachycardia pacing for ventricular tachyarrhythmias should be considered only with defibrillating back-up.  相似文献   

19.
Transesophageal atrial pacing was used to terminate hemodynamically stable sustained monomorphic ventricular tachycardia in two patients. The procedure was performed at the bedside, no anesthesia was required, there were no complications, and one of the patients went home after the procedure was performed. This method should be considered prior to using direct current cardioversion in patients with hemodynamically stable sustained monomorphic ventricular tachycardia.  相似文献   

20.