首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 156 毫秒
1.

PURPOSE

The purpose of this prospective study was to evaluate the effect of early loading on survival rate or clinical parameter of anodic oxidized implants during the 12-month postloading period.

MATERIALS AND METHODS

Total 69 implants were placed in 42 patients. Anodic oxidized implants (GS II, Osstem Cor., Busan, Korea) placed on the posterior mandibles were divided into two groups, according to their prosthetic loading times: test group (2 to 6 weeks), and control group (3 to 4 months). The implant survival rates were determined during one-year postloading period and analyzed by Kaplan-Meier method. The radiographic peri-implant bone loss and periodontal parameters were also evaluated and statistically analyzed by unpaired t-test.

RESULTS

Total 69 implants were placed in 42 patients. The cumulative postloading implant survival rates were 88.89% in test group, compared to 100% in control group (P<.05). Periimplant marginal bone loss (T: 0.27±0.54 mm, C: 0.40±0.55 mm) and periodontal parameters showed no significant difference between the groups (P>.05).

CONCLUSION

Within the limitation of the present study, implant survival was affected by early loading on the anodic oxidized implants placed on posterior mandibles during one-year follow-up. Early implant loading did not influence peri-implant marginal bone loss, and periodontal parameters.  相似文献   

2.

STATEMENT OF PROBLEM

Despite an improved bone reactions of Mg-incorporated implants in the animals, little yet has been carried out by the experimental investigations in functional loading conditions.

PURPOSE

This study investigated the clinical and histologic parameters of osseointegrated Mg-incorporated implants in early loading conditions.

MATERIAL AND METHODS

A total of 36 solid screw implants (diameter 3.75 mm, length 10 mm) were placed in the mandibles of 6 beagle dogs. Test groups included 18 Mg-incorporated implants. Turned titanium implants served as control. Gold crowns were inserted 4 weeks after implant placement and the dogs were immediately put on a food diet. Implants were observed for 10 weeks after loading. Radiographic assessments and stability tests were performed at the time of fixture installation, 2nd stage surgery, 4 weeks after loading, and 10 weeks after loading. Histological observations and morphometrical measurements were also performed.

RESULTS

Of 36 implants, 33 displayed no discernible mobility, corresponding to successful clinical function. There was no statistically significant difference between test implants and controls in marginal bone levels (P = .46) and RFA values. The mean BIC% in the Mg-implants was 54.5 ± 8.4%. The mean BIC% in the turned implant was 45.3 ± 12.2%. These differences between the Mg-implant and control implant were statistically significant (P = .005).

CONCLUSIONS

The anodized, Mg-incorporated implant demonstrated significantly more bone-to-implant contact (BIC) in early loading conditions.

CLINICAL IMPLICATIONS

The results of this study in beagle dogs suggest the possibility of achieving predictable stability of early loaded free-standing dental implants with Mg-incorporated surface.  相似文献   

3.

STATEMENT OF PROBLEM

Many dental clinicians are concerned about immediate loading of inserted implants. However, there have been few clinical studies surveying the success rates of immediate loading, based on Korean implant systems.

PURPOSE

The aim of this study was to evaluate the outcome of immediate functional loading of the implant (SinusQuick™ EB, Neobiotech Co., Seoul, Korea) in partially edentulous maxilla or mandible.

MATERIAL AND METHODS

Total 15 implants were placed. Within 2 weeks after implant insertion, provisional implant-supported fixed partial dentures were delivered to the patients. Quantitatively, marginal bone loss was measured at the time of immediate loading, after 3-months of continued loading and at the last follow-up. The mean follow-up period was 4.8 months.

RESULTS

Mean marginal bone loss from implant surgery to early loading, 3-months follow-up and last follow-up was 0.03 ± 0.07 mm, 0.16 ± 0.17 mm and 0.29 ± 0.19 mm. No implant failed up to 6 months after insertion, resulting in a 100% survival rate.

CONCLUSION

Immediate loading exhibited high success rate in partial edentulism for up to 6 months. Well-controlled long term clinical studies with large sample size are necessary to confirm this finding.  相似文献   

4.

PURPOSE

Template-guided implant therapy has developed hand-in-hand with computed tomography (CT) to improve the accuracy of implant surgery and future prosthodontic treatment. In our present study, the accuracy and causative factors for computer-assisted implant surgery were assessed to further validate the stable clinical application of this technique.

MATERIALS AND METHODS

A total of 102 implants in 48 patients were included in this study. Implant surgery was performed with a stereolithographic template. Pre- and post-operative CTs were used to compare the planned and placed implants. Accuracy and related factors were statistically analyzed with the Spearman correlation method and the linear mixed model. Differences were considered to be statistically significant at P≤.05.

RESULTS

The mean errors of computer-assisted implant surgery were 1.09 mm at the coronal center, 1.56 mm at the apical center, and the axis deviation was 3.80°. The coronal and apical errors of the implants were found to be strongly correlated. The errors developed at the coronal center were magnified at the apical center by the fixture length. The case of anterior edentulous area and longer fixtures affected the accuracy of the implant template.

CONCLUSION

The control of errors at the coronal center and stabilization of the anterior part of the template are needed for safe implant surgery and future prosthodontic treatment.  相似文献   

5.

Background

Extensive literature exists about the use of the BFP in the treatment of oral defects but, to our knowledge, no article refers to the use of the BFP as a substitute of the membrane barriers for treatment of peri-implant bone defects. The aim was to evaluate the use of the buccal fat pad as a coating material for bone grafting in the peri-implant bone defect regeneration of immediate implants placed in the posterior maxilla.

Material and Methods

A preliminary prospective study of patients involving immediate implants in which the buccal fat pad was used as a coating material to peri-implant bone defects was carried out. The outcome measures assessed were: postoperative pain and swelling, complications related to buccal fat pad surgery, implant survival and success rates and peri-implant marginal bone loss at 12 months of prosthetic loading.

Results

Twenty-seven patients (17 women and 10 men) with a mean age of 55.3 ± 8.9 years, and a total of 43 implants were included. Two-thirds of the patients reported either no pain or only mild intensity pain and moderate inflammation, two days after surgery. Post-operative period was well tolerated by the patients and no serious complications occurred. None wound dehiscence occurred. Implant survival and success rates were 97.6% and the average marginal bone loss 1 year after loading was 0.58 ± 0.27 mm.

Conclusions

Within the limits of this preliminary study, the use of the buccal fat pad as a coating material for bone grafting in peri-implant bone defects placed in the upper posterior maxilla was a well-tolerated technique by patients; high implant success rate was achieved with a minimal peri-implant marginal bone loss at 12 months of prosthetic loading. Key words:Buccal fat pad, immediate implant, peri-implant bone defect.  相似文献   

6.

PURPOSE

The aim of this retrospective study was to evaluate cumulative survival rate (CSR) of Implantium implants followed for 5 years and association between risk factors and the CSR.

MATERIALS AND METHODS

A total of two hundred forty-nine Implantium Implants System (Dentium, Seoul, Korea) placed in ninety-five patients from 2004 to 2009 were investigated with several identified risk factors (sex, systemic disease, smoking, alchohol, reason of tooth loss, length, arch (maxilla or mandible), replace tooth type (incisor, canine, premolar or molar) Kennedy classification, prosthodontic type, prosthodontic design, opposite dentition, abutment type, occlusal material, occlusal unit, splint to tooth, cantilever, other surgery). Clinical examination (mobility, percussion, screw loosening, discomfort, etc.) and radiographic examination data were collected from patient records including all problems during follow-up period according to protocols described earlier. Life table analysis was undertaken to examine the CSR. Cox regression method was conducted to assess the association between potential risk factors and overall CSR.

RESULTS

Five of 249 implants were failed. Four of these were lost before loading. The 5-year implant cumulative survival rate was 97.37%. Cox regression analysis demonstrated a significant predictive association between overall CSR and systemic disease, smoking, reason of tooth loss, arch, Kennedy classification and prosthodontic design (P<.05). The screw related complication was rare. Two abutment screw fractures were found. Another complications of prosthetic components were porcelain fracture, resin facing fracture and denture fracture (n=19).

CONCLUSION

The 5-year CSR of Implantium implants was 97.37%. Implant survival may be dependent upon systemic disease, smoking reason of tooth loss, arch, Kennedy classification and prosthodontic design (P<.05). The presence of systemic diseases and combination of other surgical procedures may be associated with increased implant failure.  相似文献   

7.

STATEMENT OF PROBLEM

Little information is available about the buccal gingival level of multiple implant restorations.

PURPOSE

This study was aimed to evaluate the relationship between width and height of buccal soft tissue around single and 2 adjacent implant restorations.

MATERIAL AND METHODS

Four implant restoration groups (first and second molars, single second molars, posterior single restorations between teeth, and anterior single restorations between teeth) were randomly chosen from one dental institute. Each group comprised of 6 patients. After 6 months of function, silicone impressions were taken and stone models were fabricated for each restoration group. The stone models were cut in bucco-lingual direction at the most apical point of buccal gingival margin. The height and width of buccal supra-implant soft tissue were measured. One way ANOVA and Tukey HSD post hoc tests were performed to analyze the data obtained (P < .05).

RESULTS

The most unfavorable width-height ratio was noted for the group, which was comprised of the second molar in the multiple adjacent (first and second molar) implant-supported restorations. The group also resulted in the shorter height of buccal supra-implant mucosa rather than that of anterior single implant restorations between natural teeth.

CONCLUSION

To achieve a favorable level of buccal gingival margin, greater thickness of buccal supra-implant mucosa is required for the implant restorations without a neighboring natural tooth compared to the implant restorations next to a natural tooth.  相似文献   

8.

PURPOSE

This study evaluated the initial stability of different implants placed above the bone level in different types of bone.

MATERIALS AND METHODS

As described by Lekholm and Zarb, cortical layers of bovine bone specimens were trimmed to a thickness of 2 mm, 1 mm or totally removed to reproduce bone types II, III, and IV respectively. Three Implant system (Brånemark System® Mk III TiUnite™, Straumann Standard Implant SLA®, and Astra Tech Microthread™-OsseoSpeed™) were tested. Control group implants were placed in level with the bone, while test group implants were placed 1, 2, 3, and 4 mm above the bone level. Initial stability was evaluated by resonance frequency analysis. Data was statistically analyzed by one-way analysis of variance in confidence level of 95%. The effective implant length and the Implant Stability Quotient (ISQ) were compared using simple linear regression analysis.

RESULTS

In the control group, there was a significant difference in the ISQ values of the 3 implants in bone types III and IV (P<.05). The ISQ values of each implant decreased with increased effective implant length in all types of bone. In type II bone, the decrease in ISQ value per 1-mm increase in effective implant length of the Brånemark and Astra implants was less than that of the Straumann implant. In bone types III and IV, this value in the Astra implant was less than that in the other 2 implants.

CONCLUSION

The initial stability was much affected by the implant design in bone types III, IV and the implant design such as the short pitch interval was beneficial to the initial stability of implants placed above the bone level.  相似文献   

9.

PURPOSE

This study conducted an analysis of cost-effectiveness of the implant and conventional fixed dental prosthesis (CFDP) from a single treatment perspective.

MATERIALS AND METHODS

The Markov model for cost-effectiveness analysis of the implant and CFDP was carried out over maximum 50 years. The probabilistic sensitivity analysis was performed by the 10,000 Monte-Carlo simulations, and cost-effectiveness acceptability curves (CEAC) were also presented. The results from meta-analysis studies were used to determine the survival rates and complication rates of the implant and CFDP. Data regarding the cost of each treatment method were collected from University Dental Hospital and Statistics Korea for 2013. Using the results of the patient satisfaction survey study, quality-adjusted prosthesis year (QAPY) of the implant and CFDP strategy was evaluated with annual discount rate.

RESULTS

When only the direct cost was considered, implants were more cost-effective when the willingness to pay (WTP) was more than 10,000 won at 10th year after the treatment, and more cost-effective regardless of the WTP from 20th year after the prosthodontic treatment. When the indirect cost was added to the direct cost, implants were more cost-effective only when the WTP was more than 75,000 won at the 10th year after the prosthodontic treatment, more than 35,000 won at the 20th year after prosthodontic treatment.

CONCLUSION

The CFDP was more cost-effective unless the WTP was more than 75,000 won at the 10th year after prosthodontic treatment. But the cost-effectivenss tendency changed from CFDP to implant as time passed.  相似文献   

10.
11.

Introduction

Replacement of missing tooth has evolved from removable dentures to fixed dentures and recently to dental implants. The need of sufficient bone around the endosseous implant is critical for the success of the implant. The present study was aimed to evaluate the efficacy of a novel implant (HYBRID IMPLANT-submitted for patency) for replacement of the missing teeth.

Materials and methods

1. Research design A prospective research design with a follow up after 1st week ,2nd week ,3rd week,1st month ,3rd month,6th month and 1st year postoperatively. 2. Sampling method Population: All patients who reported for replacement of missing teeth. Inclusion criteria 1. All patients above the age group of 16years 2. Patients who need replacement of single or multiple teeth in the anterior or posterior region of the maxilla and mandible. Exclusion criteria 1. Medically compromised patients. 2. Patients having craniofacial syndromes. 3. Sample size 5 patients were selected taking into consideration the inclusion and exclusion Criteria. Results PAIN All the patients were non symptomatic during the 1st month to 1st year postoperative periods.

Mobility

We experienced mobility during the 1st and 2nd postoperative periods where the implants were inserted in the mandibular molar region.

Bone loss

Radiographic assessment showed no bone loss during the postoperative periods.

Conclusion

The novel implant (hybrid implant) showed good stability and minimum patient discomfort during one year postoperative period evaluation. The implant system leads to new prospect in the field of prosthetic rehabilitation.  相似文献   

12.

PURPOSE

To present a literature review on implant overdentures after a brief survey of bone loss after extraction of all teeth.

MATERIALS AND METHODS

Papers on alveolar bone loss and implant overdentures have been studied for a narrative review.

RESULTS

Bone loss of the alveolar process after tooth extraction occurs with great individual variation, impossible to predict at the time of extraction. The simplest way to prevent bone loss is to avoid extraction of all teeth. To keep a few teeth and use them or their roots for a tooth or root-supported overdenture substantially reduces bone loss. Jaws with implant-supported prostheses show less bone loss than jaws with conventional dentures. Mandibular 2-implant overdentures provide patients with better outcomes than do conventional dentures, regarding satisfaction, chewing ability and oral-health-related quality of life. There is no strong evidence for the superiority of one overdenture retention-system over the others regarding patient satisfaction, survival, peri-implant bone loss and relevant clinical factors. Mandibular single midline implant overdentures have shown promising results but long-term results are not yet available. For a maxillary overdenture 4 to 6 implants splinted with a bar provide high survival both for implants and overdenture.

CONCLUSION

In edentulous mandibles, 2-implant overdentures provide excellent long-term success and survival, including patient satisfaction and improved oral functions. To further reduce the costs a single midline implant overdenture can be a promising option. In the maxilla, overdentures supported on 4 to 6 implants splinted with a bar have demonstrated good functional results.  相似文献   

13.

Background

This study aims to evaluate the technique of sinus bone reformation, which consists of elevating the sinus membrane and placement the implant without bone graft, compared with the widely-used technique involving raising the maxillary sinus and grafting, using animal hydroxyapatite as the filler, while simultaneously fixing the implants.

Material and Methods

This is a retrospective study on two groups of patients who underwent elevation of the sinus membrane and simultaneous placement of the implant. The grafting technique was applied to one group, while the other had no graft. An alveolar ridge height of 4 to 7 mm was necessary. Radiological control was undertaken at 6 months and one year post-prosthetic loading. In each group 38 implants were placed.

Results

No significant behavioural differences were observed in the implants according to the Albrektsson success criteria. Implant failure was observed in 2 implants from the bone grafting group (success rate 93%) and in 1 implant from the reformation group (success rate 97%). In this group, bone formation was observed on both sides of each implant, the bone gain was measured using image management software (2.7±0.9mm mesial and 2.6±0.9mm distal). There was no correlation between mesial and distal bone gain and implant´s length.

Conclusions

The results indicate that bone reformation is a valid technique in cases involving atrophy of the posterior maxilla. Primary stability, maintenance of space by the implant, and the formation of a blood clot are crucial in this technique in order to achieve bone formation around the implant. It is an alternative to the conventional technique of sinus lift with filling material, and has several advantages over this procedure, including a lower infection risk, as it does not involve a biomaterial, reduced cost, a simpler technique, and better acceptance by the patient. Key words:Bone formation, sinus membrane elevation, maxillary sinus, bone grafting.  相似文献   

14.

STATEMENT OF PROBLEM

A number of studies about the nano-treated surfaces of implants have been conducting along with micro-treated surfaces of implants.

PURPOSE

The purpose of this study was to get information for the clinical use of nano-treated surfaces compared with micro-treated surfaces by measuring removal torque and analyzing histological characteristics after the placement of various surface-treated implants on femurs of dogs.

MATERIAL AND METHODS

Machined surface implants were used as a control group. 4 nano-treated surface implants and 3 micro-treated surface implants [resorbable blast media surface (RBM), sandblast and acid-etched surface (SAE), anodized RBM surface] were used as experimental groups. Removal torque values of implants were measured respectively and the histological analyses were conducted on both 4weeks and 8weeks after implant surgery. The surfaces of removed implants after measuring removal torque values were observed by scanning electron microscopy (SEM) at 8 weeks.

RESULTS

1. Removal torque values of the nano-treated groups were lower than those of micro-treated groups. 2. Removal torque values were similar in the anodized RBM surface groups. 3. On the histological views, there was much of bone formation at 8 weeks, but there was no difference between 4 and 8 weeks, and between the types of implant surfaces as well.

CONCLUSION

It is suggested that implant topography is more effective in removal torque test than surface chemistry. To get better clinical result, further studies should be fulfilled on the combined effect of surface topography and chemistry for the implant surface treatments.  相似文献   

15.

PURPOSE

The purpose of this study was to assess the difference in efficacy between calcium metaphosphate (CMP)-coated implant fixtures and conventional resorbable blasted media (RBM) processed implant fixtures.

MATERIALS AND METHODS

This study targeted 50 implants from 44 patients who visited Dankook University Dental Hospital. Implantations were done separately for RBM treated and CMP-coated implants, although their design was the same. Calcium metaphosphate has a quicker biodegradation process through hydrolysis compared to other phosphate calcium groups. For the first year of the implantation, the resorption volume of marginal bone analyzed via radiography and perio-test value were measured, under the check plan. Their analyses were composed of a non-inferiority trials test. A 95% level of reliability was used.

RESULTS

In the comparative analysis of the resorption volume of marginal bone and the perio-test value, no statistically significant difference was found between the CMP-coated implants and RBM implants.

CONCLUSION

One year after the implant placement, CMP-coated implants were found not to be inferior to the conventional RBM implants.  相似文献   

16.

Aims and objective

The aim of the study is to evaluate clinically and radiographically the long term success of one-stage direct (lateral) sinus lift procedure using alloplastic bone graft material and bio-absorbable membrane in conjunction with two stage implant placement in atrophic partially edentulous posterior maxilla.

Materials and methods

One stage direct maxillary sinus lift in conjunction with two stage implant placement was carried out in 12 patients at 13 sites. All the patients were partially edentulous with posterior maxillary alveolar ridge height of >5 mm and were in the age group of 20–50 years. Bioactive glass putty, bio-absorbable collagen membrane and 3.75 × 11.5 mm implants were used. Loading of implants was done 6 months after placement of implants. Patients were evaluated clinically and radio-graphically 6, 18, 30 months after placement of implants to assess increase in residual ridge height, peri-implant condition (marginal bone loss, plaque and gingival index) and implant stability.

Results

Maxillary first molar was the most common site (69.23 %) for sinus lift and implant placement. Caries was the most common cause (76.92 %) for loss of tooth. Increase in residual ridge height ranged from (71.43 to 133.33 %) as measured by Denta-Scan. Implant survival rate was 100 %. Marginal bone loss ranged from 0.68 to 1.22 mm. Implant stability was measured by periotest (−2.7 to −3.6). Only one patient had perforation of sinus membrane, but it was sealed satisfactorily by bio-absorbable membrane.

Conclusion

One stage lateral sinus lift procedure with alloplastic bone graft material in combination with 2 stage implant placement has a predictable outcome in patients with severe resorption of posterior maxilla.  相似文献   

17.

Objective

The objective of this research was to evaluate implant stability following sinus lift with two grafting materials, and to compare it with the results obtained for the implants placed in a pristine posterior maxilla.

Materials and methods

The study included 44 healthy patients with an existing indication for sinus lift procedure (test group). 46 implants were placed following sinus lift with a pure-phase beta-tricalcium phosphate, while 39 implants were placed following augmentation with 60% hydroxyapatite with 40% beta-tricalcium phosphate material. The control group consisted of 48 healthy patients who were treated with 85 implants but without bone augmentation in posterior maxilla. Astra Tech OsseoSpeed implants were placed in all subjects. Resonance frequency analysis was used in both groups for determining implant stability 4 months after insertion. A mean implant stability quotient (ISQ) was calculated on the basis of 3 measurements.

Results

No statistical difference was observed in ISQ values of implants placed with and without augmentation procedure (p=0,789). Statistically significant difference was not found when ISQ values of implants placed following particular grafting material were compared with ISQ values of corresponding implants in a pristine bone (p=0.697 and p=0.402).

Conclusions

This study demonstrated that the implant stability is comparable among implants placed in the posterior maxilla regardless of sinus lift and grafting procedure. Implants placed in the grafted posterior maxilla can be predictably loaded as the implants placed in a non-grafted, pristine maxilla.Key words: Dental Implants, Sinus Floor Augmentation, Resonance Frequency Analysis, Beta-tricalcium Phosphate, Hydroxyapatite  相似文献   

18.

STATEMENT OF PROBLEM

Macroscopic and especially microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Dental implants with modified surfaces have shown stronger osseointegration than implants which are only turned (machined). Advanced surface modification techniques such as anodic oxidation and Ca-P application have been developed to achieve faster and stronger bonding between the host bone and the implant.

PURPOSE

The purpose of this study was to investigate the effect of surface treatment of titanium dental implant on implant stability after insertion using the rabbit tibia model.

MATERIAL AND METHODS

Three test groups were prepared: sandblasted, large-grit and acid-etched (SLA) implants, anodic oxidized implants, and anodized implants with Ca-P immersion. The turned implants served as control. Twenty rabbits received 80 implants in the tibia. Resonance frequencies were measured at the time of implant insertion, 2 weeks and 4 weeks of healing. Removal torque values (RTV) were measured 2 and 4 weeks after insertion.

RESULTS

The implant stability quotient (ISQ) values of implants for resonance frequency analysis (RFA) increased significantly (P < .05) during 2 weeks of healing period although there were no significant differences among the test and control groups (P > .05). The test and control implants also showed significantly higher ISQ values during 4 weeks of healing period (P < .05). No significant differences, however, were found among all the groups. All the groups showed no significant differences in ISQ values between 2 and 4 weeks after implant insertion (P > .05). The SLA, anodized and Ca-P immersed implants showed higher RTVs at 2 and 4 weeks of healing than the machined one (P < .05). However, there was no significant difference among the experimental groups.

CONCLUSION

The surface-modified implants appear to provide superior implant stability to the turned one. Under the limitation of this study, however, we suggest that neither anodic oxidation nor Ca-P immersion techniques have any advantage over the conventional SLA technique with respect to implant stability.  相似文献   

19.

STATEMENT OF PROBLEM

Primary stability at the time of implant placement is related to the level of primary bone contact. The level of bone contact with implant is affected by thread design, surgical procedure and bone quality, etc.

PURPOSE

The aim of this study was to compare the initial stability of the various taper implants according to the thread designs, half of which were engaged to inferior cortical wall of type IV bone (Group 1) and the rest of which were not engaged to inferior cortical wall (Group 2) by measuring the implant stability quotient (ISQ) and the removal torque value (RTV).

MATERIAL AND METHODS

In this study, 6 different implant fixtures with 10 mm length were installed. In order to simulate the sinus inferior wall of type IV bone, one side cortical bone of swine rib was removed. 6 different implants were installed in the same bone block following manufacturer''s recommended procedures. Total 10 bone blocks were made for each group. The height of Group 1 bone block was 10 mm for engagement and that of group 2 was 13 mm. The initial stability was measured with ISQ value using Osstell mentor® and with removal torque using MGT50 torque gauge.

RESULTS

In this study, we found the following results. 1. In Group 1 with fixtures engaged to the inferior cortical wall, there was no significant difference in RTV and ISQ value among the 6 types of implants. 2. In Group 2 with fixtures not engaged to the inferior cortical wall, there was significant difference in RTV and ISQ value among the 6 types of implants (P < .05). 3. There was significant difference in RTV and ISQ value according to whether fixtures were engaged to the inferior cortical wall or not (P < .05). 4. Under-drilling made RTV and ISQ value increase significantly in the NT implants which had lower RTV and ISQ value in Group 2 (P < .05).

CONCLUSIONS

Without being engaged to the inferior cortical wall fixtures had initial stability affected by implant types. Also in poor quality bone, under-drilling improved initial stability.  相似文献   

20.

Purpose

The aim of the study was to analyze the amount of maxillary and mandibular crestal bone loss around Bredent Sky Blue type of implants of different dimensions one year after implantation.

Materials and Methods

36 implants of diameter 3.5 x 10 mm were inserted in the maxilla and 12 in the mandible. 52 implants of diameter 4.0 x 8 mm were inserted in the maxilla, and 61 in the mandible (two-stage implant surgery).

Results

No statistically significant differences were found between the right and left side of the maxilla and between the right and left side of the mandible at the implant sites regarding distal and mesial bone losses as shown by analysis of variance (ANOVA).

Conclusion

Statistically significant differences were found between anterior maxilla, posterior maxilla and anterior mandible and posterior mandible at implant sites regarding distal and mesial bone losses as shown by analysis of variance (ANOVA).Key words: Alveolar Bone Loss, Bone Resorption, Dental Implants, Maxilla, Mandible  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号