首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
目的 探讨股动脉穿刺后采用Angio-Seal血管闭合器发生并发症的危险因素并建立预测模型,为临床护理提供参考.方法 收集经股动脉入路行介入治疗、采用Angio-Seal血管闭合器的611例患者资料,行单因素和多因素Logistic回归分析并发症危险因素,建立风险预测模型进行验证.结果 体重指数、低分子肝素、鞘管尺寸、...  相似文献   

2.
We report three cases of lower limb ischemia occurring after the use of arterial puncture closure devices (APCDs). In two patients, who have undergone percutaneous angioplasty of lower limb arteries, the Angio-Seal APCD led to thrombosis of the common femoral artery. In another patient who has undergone coronary angiography, this device has led to dissection of the common femoral artery. Since these observations seem to not be merely sporadic, radiologists and cardiologists as well as vascular surgeons should be aware of their possible occurrence in order to avoid these complications and to provide promptly an adequate treatment.  相似文献   

3.
Arterial percutaneous closure devices (APCD) could lead to severe vascular complications, like acute lower limb ischemia. The aim of this study was to evaluate retrospectively our personal series of acute lower limb ischemia following the use of APCD. From January 2004 to June 2009 the Angio-Seal percutaneous closure devices was deployed in 198 patients. Eight (4%) acute lower limb ischemia required urgent surgical repair. The device was removed in all cases. A thromboembolectomy was performed in five patients (62.5%) and in three (37.5%) an endarterectomy with patch closure was carried out (two saphenous vein and one Dacron). Limb salvage rate was 87.5%. We compared Angio-Seal complications group (A) with the 190 patients in which the Angio-Seal was successfully used without complications (group B) by means of Student's t-test. At 36-month follow-up with color-coded duplex ultrasounds, no chronic limb ischemia or other complications requiring surgical repair occurred. Diabetes, obesity, severe femoral atherosclerotic involvement, use of sheath size >7 Fr and time-consuming procedures were significant risk factors for ischemic APCD complications. Despite vascular injuries being uncommon after APCD deployment, generally a complex surgical repair is necessary. A more careful patient selection would be advisable.  相似文献   

4.
Surgical complications from hemostatic puncture closure devices   总被引:6,自引:0,他引:6  
BACKGROUND: For securing immediate hemostasis following percutaneous arterial catheterization, the Food and Drug Administration has approved three hemostatic puncture closure devices. We reviewed our institutional experience with one device (Angio-Seal). METHODS: A retrospective, single-center, nonrandomized observational study was made of all vascular complications following femoral cardiac catheterization. RESULTS: An immediate mechanical failure of the device was experienced in 34 (8%) patients. Surgical repair was required in 1.6% (7 of 425) of patients following Angio-Seal versus 0.3% (5 of 1662) following routine manual compression (P = 0.004). In 5 patients, the device caused either complete occlusion or stenosis of the femoral artery. The polymer anchor embolized in 1 patient and was retrieved with a balloon catheter at surgery. CONCLUSION: During the first year of utilization of a percutaneous hemostatic closure device following cardiac catheterization, we observed a marked increase in arterial occlusive complications requiring surgical repair. Surgeons must be familiar with the design of these devices to achieve precise repair of surgical complications.  相似文献   

5.
PURPOSE: This study retrospectively evaluated the efficacy and safety of the 6F Angio-Seal (St. Jude Medical, St. Paul, Minn) as a closure device for transbrachial artery access for endovascular procedures in diabetic patients with critical limb ischemia. METHODS: From January 2005 and September 2007, 1887 diabetic patients underwent interventional procedures in the lower limbs at a two diabetic foot centers. Patients presented with rest pain (16%), ulcers (80%), or gangrene (4%). Systemic anticoagulation with sodium heparin (70 IU/kg) was obtained for all patients at the beginning of the endovascular treatment. A total of 249 brachial arteries (238 patients) were evaluated for possible Angio-Seal use after endovascular recanalization of the leg. Color Doppler ultrasound imaging of the artery was obtained before revascularization only in patients with previous Angio-Seal placement in the brachial artery. No further imaging studies were done in the remaining brachial arteries where the Angio-Seal was deployed at the operator's discretion. Impairment or disappearance of the radial pulse or onsets of hand ischemia or hand pain, or impairment of hand function during or at the end of the endovascular revascularization were all regarded as contraindications to Angio-Seal usage. Evidence of a highly calcified plaque of the brachial artery access site at the time of vessel puncture was regarded as an absolute contraindication to the Angio-Seal use. Patients were seen before discharge, at 1, 3, and 8 weeks after the procedure, and at 3-month intervals thereafter. Complications included hemorrhage, pseudoaneurysm, infection, and vessel occlusion. RESULTS: A total of 1947 Angio-Seal collagen plugs were deployed in 1709 diabetic patients (90.5%). The Angio-Seal was used for brachial artery closure in 159 patients (8.4%) in 161 procedures (159 in the left, 2 in the right brachial artery). In 79 patients (4.2%) in 88 procedures (87 in the left and 1 in the right brachial artery), the device was deemed contraindicated due to small vessel size in 73 patients (92.4%) or presence of calcium at the access site in five patients (6.3%). One patient (1.3%) refused the collagen plug closure after revascularization. The non-Angio-Seal group was evaluated for comparison. The success rate for achieving hemostasis in the Angio-Seal group was 96.9%. Five major complications (3.1%) at 30 days consisted of two puncture site hematomas >4 cm, two brachial artery occlusions, and one brachial artery pseudoaneurysm, with three patients requiring open surgery. Minor complications (7.50%) were three puncture site hematomas < 4 cm, three oozing of blood from the access site, and six patients had mild pain in the cubital fossa. No further complications were recorded in the 14-month follow-up (range 1-25 months) of a total of 140 patients. CONCLUSIONS: This retrospective study shows that the 6F Angio-Seal is a valuable and safe vascular closure device for transbrachial access in diabetic patients undergoing interventional procedures for critical limb ischemia.  相似文献   

6.
The Angio-Seal arterial closure device is widely used to prevent bleeding and facilitate early ambulation after arterial puncture. We had referred to us three female patients in whom this device had been used; its sponge had been unintentionally deployed in the arterial lumen. In a fourth female patient, a dissected plaque underneath the device occluded the femoral artery. Severe lower extremity ischemia occurred in each case. One intraluminal sponge was detected only after 20 days, when the patient had developed severe symptoms due to microembolization; in another patient, ischemia occurred 9 days after intraluminal deployment. In two, or possibly three, of the cases, the superficial femoral artery had been punctured. The device should not be used when the superficial femoral artery has been punctured, in which case complications are more likely to occur. Lower limb ischemia within several months after deployment of these devices should be investigated with duplex ultrasound scanning to examine the possibility that the ischemia may be caused by the device or by device-related thrombus. It is important to register the use of such devices in the procedural reports to make it possible to link their use to eventual later ischemic events.  相似文献   

7.
Groin vessels are most commonly used to obtain vascular access for angiography because of their size and accessibility. Haemostasis at the puncture site can be achieved with manual compression alone or by using a vascular closure device. We highlight the case of a 68-year-old woman who developed acute claudication in the right leg after a routine diagnostic coronary angiogram when an Angio-Seal(?) device had been employed to close a relatively low arterial puncture. On exploring the common femoral artery, fragments of the device were found occluding the bifurcation. A patch angioplasty was carried out and the patient's claudicant symptoms improved. The Angio-Seal(?) device has a polylactide and polyglycolide polymer anchor, a collagen plug and a suture contained within a carrier system. Haemostasis is achieved by compressing the arterial puncture site between the anchor and the collagen plug. The manufacturer's recommended criterion for using the device safely permits its use only for common femoral artery punctures with an internal vessel diameter of 4mm. Anatomical confirmation of the puncture site and evidence of any arterial disease or stenosis in the artery is detected on fluoroscopy during the procedure. Recent meta-analyses have cast doubt on the assumption that vascular closure devices are superior to mechanical compression alone and serious complications do occur occasionally but are under-reported. Clinicians should be aware of the potentially serious problems that may occur when deciding to employ vascular closure devices, especially with an anatomically low puncture site.  相似文献   

8.
Percutaneous arterial closure devices allow earlier mobilization and discharge of patients after arterial catheterization than with manual compression for puncture site hemostasis. We reviewed our recent experience managing the complications of femoral artery catheterization with and without these devices on the vascular surgery service at a tertiary hospital. Thirty-one patients presenting over an 18-month period with complications after femoral artery catheterization with manual compression (n = 21) or percutaneous arterial closure devices (n = 10) were retrospectively reviewed.  相似文献   

9.
Femoral artery closure devices are increasingly used after percutaneous arterial interventions to obtain hemo-stasis at the puncture site. Their efficacy and advantages in patient comfort are established. Nevertheless they can cause their own specific complications. In a five month’s period we had to treat four patients with sudden onset invalidating claudication after the use of an Angio-Seal closure device. Malpositioning of the device led to the ischemic complications. We describe and illustrate the pre-and peroperative findings and the treatment. Interventionalists should monitor and register ischemic complications following the use of puncture site closure devices in order to try and minimize these. The occurrence of few serious complications can outweigh the relative small benefits these devices offer.  相似文献   

10.
Femoral artery closure devices are increasingly used after percutaneous arterial interventions to obtain hemostasis at the puncture site. Their efficacy and advantages in patient comfort are established. Nevertheless they can cause their own specific complications. In a five month's period we had to treat four patients with sudden onset invalidating claudication after the use of an Angio-Seal closure device. Malpositioning of the device led to the ischemic complications. We describe and illustrate the pre- and peroperative findings and the treatment. Interventionalists should monitor and register ischemic complications following the use of puncture site closure devices in order to try and minimize these. The occurrence of few serious complications can outweigh the relative small benefits these devices offer.  相似文献   

11.
PURPOSE: This study evaluated the risk factors and surgical management of complications caused by femoral artery catheterization in pediatric patients. METHODS: From January 1986 to March 2001, the hospital records of all children who underwent operative repairs for complications caused by femoral artery catheterization were reviewed. A prospective cardiac data bank containing 1674 catheterization procedures during the study period was used as a means of determining risk factors associated with iatrogenic femoral artery injury. RESULTS: Thirty-six operations were performed in 34 patients (age range, 1 week-17.4 years) in whom iatrogenic complications developed after either diagnostic or therapeutic femoral artery catheterizations during the study period. Non-ischemic complications included femoral artery pseudoaneurysms (n = 4), arteriovenous fistulae (n = 5), uncontrollable bleeding, and expanding hematoma (n = 4). Operative repairs were performed successfully in all patients with non-ischemic iatrogenic femoral artery injuries. In contrast, ischemic complications occurred in 21 patients. Among them, 14 patients had acute femoral ischemia and underwent surgical interventions including femoral artery thrombectomy with primary closure (n = 6), saphenous vein patch angioplasty (n = 6), and resection with primary anastomosis (n = 2). Chronic femoral artery occlusion (> 30 days) occurred in seven patients, with symptoms including either severe claudication (n = 4) or gait disturbance or limb growth impairment (n = 3). Operative treatments in these patients included ileofemoral bypass grafting (n = 5), femorofemoral bypass grafting (n = 1), and femoral artery patch angioplasty (n = 1). During a mean follow-up period of 38 months, no instances of limb loss occurred, and 84% of children with ischemic complications eventually gained normal circulation. Factors that correlated with an increased risk of iatrogenic groin complications that necessitated surgical intervention included age younger than 3 years, therapeutic intervention, number of catheterizations (>or= 3), and use of 6F or larger guiding catheter. CONCLUSION: Although excellent operative results can be achieved in cases of non-ischemic complications, acute femoral occlusion in children younger than 2 years often leads to less satisfactory outcomes. Operative intervention can provide successful outcome in children with claudication caused by chronic limb ischemia. Variables that correlated with significant iatrogenic groin complications included a young age, therapeutic intervention, earlier catheterization, and the use of a large guiding catheter.  相似文献   

12.
Percutaneous devices have been developed to close the femoral artery puncture site after catheterization. Because direct compression is not needed, the devices save time for the treating health-care provider, reduce patient discomfort, and obviate the need for post-catheterization bed rest. Reported complications with use of these devices are similar in nature and frequency to those accompanying direct compression. Complications of infection requiring surgical treatment are exceedingly rare with use of these devices. We describe a series of five catheterization site infections occurring among 1807 patients (0.3%) whose femoral artery puncture was closed with a percutaneous suture closure device. All patients required operative intervention and there was one late death. Physicians should be aware of this uncommon but serious complication to expedite evaluation and treatment of patients with suspected infections from these devices.  相似文献   

13.
OBJECTIVE: Use of percutaneous suture closure devices after catheter-based interventions is increasing. We recently have seen several severe femoral arterial wall infections after use of such devices. The purpose of this study was to examine the incidence, comorbid associations, and management of femoral arterial infections associated with percutaneous suture closure devices. METHODS: We retrospectively reviewed all infectious complications that occurred after 2223 consecutive cardiac catheterization procedures performed over 12 months in a university-affiliated community teaching hospital. Outcome variables included demographics, procedural details, infection, type of arterial reconstruction required, mortality, and limb loss. RESULTS: During this study, 822 patients received percutaneous suture devices. Infection developed in 6 patients (0.7%). The incidence of diabetes in the population undergoing percutaneous suture closure was 219 of 822 patients (26.6%). Three comorbid conditions, noted in multiple patients with infectious complications, included diabetes mellitus, obesity, and placement of a percutaneous suture closure device within the past 6 months. Invasive femoral endarteritis developed in 4 patients. Gram-positive cocci predominated in 4 patients. In 1 patient with polymicrobial infection catastrophic complications developed, including multiple anastomotic ruptures and hemorrhage. A new method of repair that incorporated double-thickness everted saphenous vein was used in 2 patients, and safe arterial closure was achieved. There was 1 late fatality on postoperative day 36. Limb salvage was achieved in all patients. CONCLUSIONS: Femoral endarteritis complicating percutaneous suture closure is a challenging new problem for vascular surgeons and can result in catastrophic complications. Customary techniques that use saphenous vein patch or interposition grafting are not adequate in all circumstances. Successful outcome requires operative exploration in patients with suspected infection. Removal of the percutaneous suture closure device and debridement to normal arterial wall is recommended in all patients with suspected femoral endarteritis, based on positive intraoperative Gram stains or abnormal appearance of the adjacent femoral artery. Early success with an autologous bolstered repair is reported. Caution is advised when considering the use of a percutaneous suture closure device in patients with comorbid conditions including diabetes, obesity, and previously implanted devices.  相似文献   

14.
Hemostasis obtained by manual compression after femoral artery catheterization results in consistently low rates of major complications. A rare complication of femoral artery catheterization is arterial infection. Its occurrence after diagnostic angiography using manual compression has not been reported. We report two cases of femoral arterial infection after uneventful diagnostic catheterization in nonimmunocompromised patients using the Perclose percutaneous arterial closure device. Our cases are representative of Perclose associated infections, with delayed presentation of a staphylococcal arterial infection requiring arterial debridement and reconstruction. This article indicates that Perclose use carries a risk of severe arterial infection. Surgeons should be aware of the potential infectious complications associated with Perclose use and the need for aggressive treatment.  相似文献   

15.
Introduction Percutaneous closure devices have been used to obtain rapid hemostasis and early mobilization of the patient after arterial catheterization. However, we observed challenging problems with the sealing procedure that require further surgical intervention. The present report is a retrospective analysis of the patterns of injury and the final outcome of four cases of femoral artery injury following the use of Angio-Seal. Methods During the last 24 months, in a group of 175 patients (131 men, 44 women; median age 68.4 years, range 47–81 years) underwent percutaneous closure after diagnostic (n = 53) or therapeutic (n = 122) endovascular procedures. Among them we observed four patients (three men, one woman; median age 65.2 ± 10.8 years, range 47–75 years) who developed severe limiting claudication and required vascular repair of an iatrogenic vascular injury following deployment of the Angio-Seal. They had a femoral thrombosis due to narrowing/severe intimal dissection. Results All patients required operative intervention with removal of the device. We performed femoropopliteal thrombectomy and common femoral endarterectomy with patch angioplasty (n = 2), resection of the femoral bifurcation and reimplantation of the deep femoral artery (n = 1), and femoral bifurcation endarterectomy with direct arterial suture (n = 1). The median hospital stay was 6.5 ± 3.8 days (range 4–12 days). Limb salvage was achieved in all of the surviving patients at a mean follow-up of 7 months (range 1–12 months). Conclusions Vascular injuries are uncommon after use of the hemostasis closure device. When they occur, however, they are likely to require challenging surgical correction. This work was presented at the 4th International Central European Vascular Forum in Dubrovnijk, April–May 2004.  相似文献   

16.
The use of femoral artery closure devices to obtain hemostasis after percutaneous catheterization has become widespread because of their proven feasibility in combination with patient-related advantages. Since 2002 more than 6,500 patients have undergone either diagnostic angiography or therapeutic intervention via the femoral route with an Angioseal closure device in our hospital. We were faced with six cases of limb-threatening complications, which are described here. Most (5/6) complications were of obstructive origin due to traumatic dissection or occlusion of the artery mainly caused by malpositioning of the device. Recommendations are made in order to prevent or successfully overcome this certainly increasing problem in the vascular field.  相似文献   

17.
Ischemic injuries following percutaneous femoral artery catheterization are uncommon but have been associated with vascular closure devices (VCDs). The purpose of this study was to retrospectively compare ischemic and hemorrhagic complications of femoral artery catheterization and to identify factors associated with ischemic injuries. The operative registries of the attending vascular surgeons at one academic and two community hospitals were retrospectively reviewed to identify all complications of femoral artery catheterization requiring operative intervention. Demographic, clinical, procedural, operative, and outcome data were compared between patients who sustained ischemic and hemorrhagic complications. From January 2001 to December 2006, 95 patients required operative management of complications related to femoral artery catheterization including 40 patients who experienced ischemic (group 1) and 55 patients who experienced hemorrhagic (group 2) complications. Compared to those sustaining hemorrhagic complications, ischemic complications were more frequently associated with younger age, smoking, VCD deployment, and, when controlling for VCD use, female gender. Time to presentation was also significantly longer in patients experiencing ischemic complications. Ischemic complications are increasingly recognized following femoral artery catheterization. Vascular surgeons should anticipate a new pattern of injury following femoral artery catheterization, one that often requires complex arterial reconstruction.  相似文献   

18.
BACKGROUND: Femoral access site complications have increased as the fields of invasive cardiology, radiology, and endovascular surgery have emerged. In order to address one of these complications, hemorrhage, the hemostatic puncture closure devices were developed. METHODS: Retrospective review of cardiac catheterizations performed at a single institution to investigate infectious groin complications related to use of the Perclose Prostar and Techstar devices. RESULTS: Infectious groin complications were significantly higher in the Perclose group as compared with manual compression. Three patients had clinical and laboratory evidence of arterial infection whereas 2 had soft tissue infections. All 5 required operative intervention ranging from incision and drainage to arterial reconstruction. Hemorrhagic complications were not significantly different between the two groups. CONCLUSIONS: The Perclose devices provide hemostasis after femoral artery catheterization similar to manual compression. However, infectious groin complications appear to be more common with these devices.  相似文献   

19.
The authors report their experience with 15 cases of groin complications associated with the use of percutaneous closure devices following femoral arterial catheterization over a 2-year period. The complication rate was 1.7% for catheterizations in which a closure device was used. The 15 cases included 7 uncomplicated pseudoaneurysms (PSA), 3 infected pseudoaneurysms, 4 nonarterial groin infections (infected hematomas and/or abscesses), and 1 case of femoral artery occlusion. These complications presented at an average of 5 +/- 4 days postcatheterization. One patient with an infected PSA required a below-the-knee amputation. During the same time interval, there were no infectious complications in patients not receiving closure devices. We conclude that groin complications associated with such devices tend to present late and include a higher percentage of infections as opposed to complications occurring in patients not receiving closure devices. An aggressive surgical approach to these problems appears warranted.  相似文献   

20.
In performance of hemosorption in 108 patients with acute intoxications, 210 manipulations of Seldinger's central venous puncture and catheterization, Skribner's arteriovenous shunting, section of the basal brachial vein were accomplished. In 23 (10.1%) patients, the complications developed: hematoma at the site of puncture--in 10, puncture of the subclavian artery--in 3, puncture of the femoral artery--in 6, shunt thrombosis--in 2, catheter thrombosis--in 2. In patients with acute intoxications, the use of veno-venous method of hemosorption with Seldinger's catheterization of the subclavian and femoral veins is preferrable.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏