首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 420 毫秒
1.
PURPOSE: To rapidly acquire T(1)-weighted images using a three-dimensional fast low angle shot (3D FLASH) sequence in combination with generalized autocalibrating partially parallel acquisitions (GRAPPA) and variable flip angle (VFA) method at 3.0T. MATERIALS AND METHODS: 3D T(1) maps of model systems (gadolinium [Gd] and agarose phantoms), bovine cartilage, and human subjects were constructed on a 3.0T clinical whole-body MR scanner. The T(1) values of model systems measured using the 2D inversion-recovery fast-spin-echo (IR-FSE) sequence were considered as a reference method to validate the rapid 3D method for comparison. RESULTS: The root mean square coefficient of variation percentage (RMS-CV%) of the median T(1) of agarose phantom across different acquisition methods was approximately 6.2%. The RMS-CV% of the median T(1) of bovine cartilage across different acquisition methods was approximately 4.1%. The RMS-CV% of median T(1) of the cartilages among the subjects was between approximately 7.3% to 11.1%. In our study, rapid 3D-T(1) mapping with VFA and parallel imaging with different acceleration factors (AFs) (AF = 1, 2, 3, and 4) seems to have no obvious influence on the T(1) mapping (before and after contrast agent administration). CONCLUSION: The preliminary results demonstrate that it is possible to quantify 3D-T(1) mapping of the whole knee joint (with 0.7 mm(3) isotropic resolution) under approximately five minutes with excellent in vivo reproducibility at 3.0T.  相似文献   

2.
PURPOSE: To demonstrate the feasibility of three-dimensional (3D) T(1rho)-weighted imaging of human knee joint at 3.0T without exceeding the specific absorption rate (SAR) limits and the measurement of the baseline T(1rho) values of patellar cartilage and several muscles at the knee joint. MATERIALS AND METHODS: 3D gradient-echo sequence with a self-compensating spin-lock pulse cluster of 250 Hz power was used to acquire 3D-T(1rho)-weighted images of the knee joint of five healthy subjects. Global and regional analysis of patellar cartilage T(1rho) were performed. Furthermore, T(1rho) of several periarticular muscles were analyzed. RESULTS: The global average T(1rho) value of the patellar cartilage varied from 39 to 43 msec. The regional average T(1rho) values varied from 38 to 42 msec, and from 42 to 44 msec for medial and lateral facets, respectively. In vivo reproducibility of average T(1rho) of patellar cartilage was found to be 5% (coefficient of variation). Similarly, the global average T(1rho) values for biceps femoris, lateral gastrocnemius, medial gastrocnemius, and sartorius varied between 31-46, 29-49, 35-48, and 32-50 msec, respectively. CONCLUSION: We demonstrated the feasibility of 3D-T(1rho)-weighted imaging of the knee joint at 3.0T without exceeding SAR limits.  相似文献   

3.
PURPOSE: To test the feasibility of in vivo magnetic resonance T(1rho) relaxation time measurements of hip cartilage, and quantify the reproducibility of hip cartilage thickness, volume, T(2), T(1rho), and size of femoral head measurements. MATERIALS AND METHODS: The hip joint of five human healthy volunteers, one subject with mild hip osteoarthritis (OA) and one subject with advanced hip OA, was imaged with magnetic resonance imaging (MRI) at 3T. Hip cartilage thickness, volume, T(1rho), and T(2) were quantified, as well as the size of the femoral head. All imaging and analysis procedures were performed twice for the healthy volunteers to assess reproducibility. RESULTS: In vivo MR T(1rho) measurements of hip cartilage at 3T were feasible as demonstrated by high quality images and relaxation time maps. High levels of reproducibility were obtained for measurements of hip cartilage thickness (CV(SD) = 2.19%), volume (CV(SD) = 3.5%), T(2) (CV(SD) = 5.89%), T(1rho) (CV(SD) = 2.03%), and size of femoral head (CV(SD) = 0.49%). Mean T(2) and T(1rho) relaxation time values for human healthy subjects were 28.38 (+/-2.66) msec and 38.72 (+/-3.84) msec, respectively. Mean T(2) and T(1rho) relaxation time values for subjects with OA were 34.78 (+/-8.36) msec and 44.07 (+/-0.99) msec, respectively. T(2) and T(1rho) values increased from the deep to the superficial layers. CONCLUSION: Qualitative and quantitative results indicate that the MRI techniques presented in this study may be applied clinically to patients with OA of the hip to investigate these parameters at different stages of disease.  相似文献   

4.
Parallel imaging of knee cartilage at 3 Tesla   总被引:1,自引:0,他引:1  
PURPOSE: To evaluate the feasibility and reproducibility of quantitative cartilage imaging with parallel imaging at 3T and to determine the impact of the acceleration factor (AF) on morphological and relaxation measurements. MATERIALS AND METHODS: An eight-channel phased-array knee coil was employed for conventional and parallel imaging on a 3T scanner. The imaging protocol consisted of a T2-weighted fast spin echo (FSE), a 3D-spoiled gradient echo (SPGR), a custom 3D-SPGR T1rho, and a 3D-SPGR T2 sequence. Parallel imaging was performed with an array spatial sensitivity technique (ASSET). The left knees of six healthy volunteers were scanned with both conventional and parallel imaging (AF = 2). RESULTS: Morphological parameters and relaxation maps from parallel imaging methods (AF = 2) showed comparable results with conventional method. The intraclass correlation coefficient (ICC) of the two methods for cartilage volume, mean cartilage thickness, T1rho, and T2 were 0.999, 0.977, 0.964, and 0.969, respectively, while demonstrating excellent reproducibility. No significant measurement differences were found when AF reached 3 despite the low signal-to-noise ratio (SNR). CONCLUSION: The study demonstrated that parallel imaging can be applied to current knee cartilage quantification at AF = 2 without degrading measurement accuracy with good reproducibility while effectively reducing scan time. Shorter imaging times can be achieved with higher AF at the cost of SNR.  相似文献   

5.
目的 建立MR关节软骨自旋锁定旋转坐标系中的自旋-晶格弛豫时间(T1ρ)三维成像技术和量化分析方法.方法 用7.0 T MR机和内径为6 cm的圆柱形鸟笼23Na-H射频线罔,采用自旋锁定自动补偿脉冲簇和三维自旋回波序列,自旋锁定时间(spin-locking time,TSL)分别为0、10、20、30、40和50 ms,自旋锁定频率带宽为440 Hz(自旋锁定磁场BsL),对6个不同浓度(1%~6%)琼脂糖凝胶体模和8个猪髌骨分别进行自旋锁定T1ρ成像扫描,建立自旋锁定T1ρ成像技术并评价其重复性.在Vnmr J图像终端上,利用自行编制的软件进行三维重组自旋锁定T1ρWI,并重构T1ρ弛豫时间图;采用人工标注的方法画感兴趣区,分别测定体模与髌骨软骨T1ρWI的信噪比(SNR)与T1ρ值.T1ρ值在各组间的对比,行单因素方差分析;软骨组织与琼脂糖体模SNR随时间对比关系的假设检验,行多因素方差分析.结果 关节软骨T1ρWI的SNR值、短自旋锁定时间采集图像的SNR值明显高于长自旋锁定时间采集的图像.在不同自旋锁定时间髌骨软骨T1ρWI,SNR值在48 4±8~95±8之间;不同自旋锁定时间,正常软骨SNR与1%琼脂糖体模的对比关系不同,当自旋锁定时间<30 ms时,琼脂糖体模的图像SNR均低于正常软骨;>30 ms时,正常软骨的图像SNR均低于1%的琼脂糖体模.随着琼脂糖浓度减少,不同自旋锁定时间采集的图像SNR值逐渐增加.各浓度琼脂糖凝胶体模T1ρ值测量的变异系数均小于10%,显示重复性好.髌骨关节软骨全层、表层、中间层、深层、钙化层T1ρ值测定结果分别为(68.9±6.3)、(80.7±12.8)、(65.7±7.0)、(82.4±7.7)、(69.7±6.4)ms(F=6.436,P<0.05).T1ρ值在软骨表层和深层明显高于中间层、钙化层和软骨全层.结论 三维自旋锁定T1ρ成像技术是可行的、敏感的、特异的软骨分子成像技术,T1ρ弛豫时间图可量化测量关节软骨的分层状结构.  相似文献   

6.
T(1rho) describes the spin-lattice relaxation in the rotating frame and has been proposed for detecting damage to the cartilage collagen-proteoglycan matrix in osteoarthritis. In this study, a multi-slice T(1rho) imaging method for knee cartilage was developed using spin-lock techniques and a spiral imaging sequence. The adverse effect of T(1) regrowth during the multi-slice acquisition was eliminated by RF cycling. Agarose phantoms with different concentrations, 10 healthy volunteers, and 9 osteoarthritis patients were scanned at 3T. T(1rho) values decreased as agarose concentration increased. T(1rho) values obtained with imaging methods were compared with those obtained with spectroscopic methods. T(1rho) values obtained during multi-slice acquisition were validated with those obtained in a single slice acquisition. Reproducibility was assessed using the average coefficient of variation of median T(1rho), which was 0.68% in phantoms and 4.8% in healthy volunteers. There was a significant difference (P = 0.002) in the average T(1rho) within patellar and femoral cartilage between controls (45.04 +/- 2.59 ms) and osteoarthritis patients (53.06 +/- 4.60 ms). A significant correlation was found between T(1rho) and T(2); however, the difference of T(2) was not significant between controls and osteoarthritis patients. The results suggest that T(1rho) relaxation times may be a promising clinical tool for osteoarthritis detection and treatment monitoring.  相似文献   

7.
For T(1rho) quantification, a three-dimensional (3D) acquisition is desired to obtain high-resolution images. Current 3D methods that use steady-state spoiled gradient-echo (SPGR) imaging suffer from high SAR, low signal-to-noise ratio (SNR), and the need for retrospective correction of contaminating T(1) effects. In this study, a novel 3D acquisition scheme-magnetization-prepared angle-modulated partitioned-k-space SPGR snapshots (3D MAPSS)-was developed and used to obtain in vivo T(1rho) maps. Transient signal evolving towards the steady-state were acquired in an interleaved segmented elliptical centric phase encoding order immediately after a T(1rho) magnetization preparation sequence. RF cycling was applied to eliminate the adverse impact of longitudinal relaxation on quantitative accuracy. A variable flip angle train was designed to provide a flat signal response to eliminate the filtering effect in k-space caused by transient signal evolution. Experiments in phantoms agreed well with results from simulation. The T(1rho) values were 42.4 +/- 5.2 ms in overall cartilage of healthy volunteers. The average coefficient-of-variation (CV) of mean T(1rho) values (N = 4) for overall cartilage was 1.6%, with regional CV ranging from 1.7% to 8.7%. The fitting errors using MAPSS were significantly lower (P < 0.05) than those using sequences without RF cycling and variable flip angles.  相似文献   

8.
PURPOSE: To demonstrate the in vivo feasibility of measuring spin-lattice relaxation time in the rotating frame (T(1rho)); and T(1rho)-dispersion in human femoral cartilage. Furthermore, we aimed to compute the baseline T(1rho)-relaxation times and spin-lock contrast (SLC) maps on healthy volunteers, and compare relaxation times and signal-to-noise ratio (SNR) with corresponding T(2)-weighted images. MATERIALS AND METHODS: All MR imaging experiments were performed on a 1.5 T GE Signa scanner (GEMS, Milwaukee, WI) using a custom built 15-cm transmit-receive quadrature birdcage radio-frequency (RF) coil. The T(1rho)-prepared magnetization was imaged with a single-slice two-dimensional fast spin-echo (FSE) pulse sequence preencoded with a three-pulse cluster consisting of two hard 90 degrees pulses and a low power spin-lock pulse. T(1rho)-dispersion imaging was performed by varying the spin-lock frequency from 100 to 500 Hz in five steps in addition to varying the length of the spin-lock pulse. RESULTS: The average T(1rho)-relaxation times in the weight-bearing (WB) and nonweight-bearing (NWB) regions of the femoral condyle were 42.2 +/- 3.6 msec and 55.7 +/- 2.3 msec (mean +/- SD, N = 5, P < 0.0001), respectively. In the same regions, the corresponding T(2)-relaxation times were 31.8 +/- 1.5 msec and 37.6 +/- 3.6 msec (mean +/- SD, N = 5, P < 0.0099). T(1rho)-weighted images have approximately 20%-30% higher SNR than the corresponding T(2)-weighted images for similar echo time. The average SLC in the WB region of femoral cartilage was 30 +/-4.0%. Furthermore, SLC maps provide better contrast between fluid and articular surface of femoral-tibial joint than T(1rho)-maps. The T(1rho)-relaxation times varied from 32 msec to 42 msec ( approximately 31%) in the WB and 37 msec to 56 msec ( approximately 51%) in NWB regions of femoral condyle, respectively, in the frequency range 0-500 Hz (T(1rho)-dispersion). CONCLUSION: The feasibility of performing in vivo T(1rho) relaxation mapping in femoral cartilage at 1.5T clinical scanner without exceeding Food and Drug Administration (FDA) limits on specific absorption rate (SAR) of RF energy was demonstrated.  相似文献   

9.
A multislice spin-lock (MS-SL) pulse sequence is implemented on a clinical scanner to acquire multiple images with spin-lock-generated contrast of the knee joints of six healthy human subjects. The MS-SL sequence produces images with T1rho contrast with an additional factor of intrinsic T2rho weighting, which hinders direct measurement of T1rho. A method is presented to compensate the MS-SL-generated data with regard to T2rho in an effort to accurately calculate multislice T1rho maps in a feasible experimental time. The T2rho-compensated multislice T1rho maps produced errors in the measurement of T1rho in healthy patellar cartilage of approximately 5% compared to the gold standard measurement of T1rho acquired with single-slice spin-lock pulse sequence. The MS-SL sequence has potential as an important clinical tool for the acquisition of multislice T1rho-weighted images and/or quantitative multislice T1rho maps.  相似文献   

10.
PURPOSE: To design and implement a magnetic resonance imaging (MRI) pulse sequence capable of performing three-dimensional T(1rho)-weighted MRI on a 1.5-T clinical scanner, and determine the optimal sequence parameters, both theoretically and experimentally, so that the energy deposition by the radiofrequency pulses in the sequence, measured as the specific absorption rate (SAR), does not exceed safety guidelines for imaging human subjects. MATERIALS AND METHODS: A three-pulse cluster was pre-encoded to a three-dimensional gradient-echo imaging sequence to create a three-dimensional, T(1rho)-weighted MRI pulse sequence. Imaging experiments were performed on a GE clinical scanner with a custom-built knee-coil. We validated the performance of this sequence by imaging articular cartilage of a bovine patella and comparing T(1rho) values measured by this sequence to those obtained with a previously tested two-dimensional imaging sequence. Using a previously developed model for SAR calculation, the imaging parameters were adjusted such that the energy deposition by the radiofrequency pulses in the sequence did not exceed safety guidelines for imaging human subjects. The actual temperature increase due to the sequence was measured in a phantom by a MRI-based temperature mapping technique. Following these experiments, the performance of this sequence was demonstrated in vivo by obtaining T(1rho)-weighted images of the knee joint of a healthy individual. RESULTS: Calculated T(1rho) of articular cartilage in the specimen was similar for both and three-dimensional and two-dimensional methods (84 +/- 2 msec and 80 +/- 3 msec, respectively). The temperature increase in the phantom resulting from the sequence was 0.015 degrees C, which is well below the established safety guidelines. Images of the human knee joint in vivo demonstrate a clear delineation of cartilage from surrounding tissues. CONCLUSION: We developed and implemented a three-dimensional T(1rho)-weighted pulse sequence on a 1.5-T clinical scanner.  相似文献   

11.
MR relaxation time measurements of knee cartilage have shown potential to characterize knee osteoarthritis (OA). In this work, techniques that allow localized intra- and inter-subject comparisons of cartilage relaxation times, as well as cartilage flattening for texture analysis parallel and perpendicular to the natural cartilage layers, are presented. The localized comparisons are based on the registration of bone structures and the assignment of relaxation time feature vectors to each point in the bone-cartilage interface. Cartilage flattening was accomplished with Bezier splines and warping, and texture analysis was performed with second-order texture measures using gray-level co-occurrence matrices (GLCM). In a cohort of five normal subjects the performance and reproducibility of the techniques were evaluated using T1rho maps of femoral knee cartilage. The feasibility of creating a mean cartilage relaxation time map is also presented. Successful localized intra- and inter-subject T1rho comparisons were obtained with reproducibility similar to that reported in the literature for regional T2. Improvement of the reproducibility of GLCM features was obtained by flattening the T1rho maps. The results indicate that the presented techniques have potential in longitudinal and population studies of knee OA at different stages of the disease.  相似文献   

12.
PURPOSE: To demonstrate the feasibility of using the keyhole technique to minimize error in a least squares regression estimation of T(1rho) from magnetic resonance (MR) image data. MATERIALS AND METHODS: The keyhole method of partial k-space acquisition was simulated using data from a virtual phantom and MR images of ex vivo bovine and in vivo human cartilage. T(1rho) maps were reconstructed from partial k-space (keyhole) image data using linear regression, and error was measured with relation to T(1rho) maps created from the full k-space images. An error model was created based on statistical theory and fitted to the error measurements. RESULTS: T(1rho) maps created from keyhole images of a human knee produced levels of error on the order of 1% while reducing standard image acquisition time approximately by half. The resultant errors were strongly correlated with expectations derived from statistical theory. CONCLUSION: The error model can be used to analytically optimize the keyhole method in order to minimize the overall error in the estimation of the relaxation parameter of interest. The keyhole method can be generalized to significantly expedite all forms of relaxation mapping.  相似文献   

13.
PURPOSE: To quantify the spin-lattice relaxation time in the rotating frame (T1rho) in various clinical grades of human osteoarthritis (OA) cartilage specimens obtained from total knee replacement surgery, and to correlate the T1rho with OA disease progression and compare it with the transverse relaxation time (T2). MATERIALS AND METHODS: Human cartilage specimens were obtained from consenting patients (N = 8) who underwent total replacement of the knee joint at the Pennsylvania Hospital, Philadelphia, PA, USA. T2- and T1rho-weighted images were obtained on a 4.0 Tesla whole-body GE Signa scanner (GEMS, Milwaukee, WI, USA). A 7-cm diameter transmit/receive quadrature birdcage coil tuned to 170 MHz was employed. RESULTS: All of the surgical knee replacement OA cartilage specimens showed elevated relaxation times (T2 and T1rho) compared to healthy cartilage tissue. In various grades of OA specimens, the T1rho relaxation times varied from 62 +/- 5 msec to 100 +/- 8 msec (mean +/- SEM) depending on the degree of cartilage degeneration. However, T2 relaxation times varied only from 32 +/- 2 msec to 45 +/- 4 msec (mean +/- SEM) on the same cartilage specimens. The increase in T2 and T1rho in various clinical grades of OA specimens were approximately 5-50% and 30-120%, respectively, compared to healthy specimens. The degenerative status of the cartilage specimens was also confirmed by histological evaluation. CONCLUSION: Preliminary results from a limited number of knee specimens (N = 8) suggest that T1rho relaxation mapping is a sensitive noninvasive marker for quantitatively predicting and monitoring the status of macromolecules in early OA. Furthermore, T1rho has a higher dynamic range (>100%) for detecting early pathology compared to T2. This higher dynamic range can be exploited to measure even small macromolecular changes with greater accuracy compared to T2. Because of these advantages, T1rho relaxation mapping may be useful for evaluating early OA therapy.  相似文献   

14.
Two simple methodologies for correcting the errors in T2 maps for phantom measurements are presented; they both give accurate MRI maps with a low coefficient of variation (CV). The rate correction method is based on an equation relating the true T2 (T2,t) and that determined experimentally (T2,exp) for homogenous phantoms. The response matrix method is a phenomenological analysis of the difference between T2,exp and T2,t, from which correction factors are computed for a range of T2 values and for every pixel of an image. The factors were obtained from phantoms filled with a homogeneous gelatin gel and having different T2,t values. The CV in homogeneous phantom measurements were reduced from 2.5-4.0% to approximately 0.6-2.0% for T2,t values ranging from 180-600 ms. Examples are shown for the correction of T2 maps of phantoms filled with polymer dosimeter gel irradiated with photon beams from a linear accelerator. The methodologies presented can easily be implemented on a clinical MRI scanner.  相似文献   

15.

Objective

It was reported lately that to obtain consistent liver T1rho measurement, at 3T MRI using six spin-lock times (SLTs), is feasible. In this study, the feasibility of using three or two SLT points to measure liver T1rho relaxation time was explored.

Materials and Methods

Seventeen healthy volunteers underwent 36 examinations. Three representative axial slices were selected to cut through the upper, middle, and lower liver. A rotary echo spin-lock pulse was implemented in a 2D fast field echo sequence. Spin-lock frequency was 500 Hz and the spin-lock times of 1, 10, 20, 30, 40, and 50 milliseconds (ms) were used for T1rho mapping. T1rho maps were constructed by using all 6 SLT points, three SLT points of 1, 20, and 50 ms, or two SLTs of 1 and 50 ms, respectively. Intra-class correlation coefficient (ICC) and Bland and Altman plot were used to assess the measurement agreement.

Results

Two examinations were excluded, due to motion artifact at the SLT of 50 ms. With the remaining 34 examinations, the ICC for 6-SLT vs. 3-SLT T1rho measurements was 0.922, while the ICC for 6-SLT vs. 2-SLT T1rho measurement was 0.756. The Bland and Altman analysis showed a mean difference of 0.19 (95% limits of agreement: -1.34, 1.73) for 6-SLT vs. 3-SLT T1rho measurement, and the mean difference of 0.89 (95% limits of agreement: -1.67, 3.45) for 6-SLT vs. 2-SLT T1rho measurement. The scan re-scan reproducibility ICC (n = 11 subjects) was 0.755, 0.727, and 0.528 for 6-SLT measurement, 3-SLT measurement, and 2-SLT measurement, respectively.

Conclusion

Adopting 3 SLTs of 1, 20, and 50 ms can be an acceptable alternative for the liver T1rho measurement, while 2 SLTs of 1 and 50 ms do not provide reliable measurement.  相似文献   

16.
Variations in the intrinsic T(1) and T(2) relaxation times have been implicated in numerous neurologic conditions. Unfortunately, the low resolution and long imaging time associated with conventional methods have prevented T(1) and T(2) mapping from becoming part of routine clinical evaluation. In this study, the clinical applicability of the DESPOT1 and DESPOT2 imaging methods for high-resolution, whole-brain, T(1) and T(2) mapping was investigated. In vivo, 1-mm(3) isotropic whole-brain T(1) and T(2) maps of six healthy volunteers were acquired at 1.5 T with an imaging time of <17 min each. Isotropic maps (0.34 mm(3)) of one volunteer were also acquired (time <21 min). Average signal-to-noise within the 1-mm(3) T(1) and T(2) maps was approximately 20 and approximately 14, respectively, with average repeatability standard deviations of 46.7 ms and 6.7 ms. These results demonstrate the clinical feasibility of the methods in the study of neurologic disease.  相似文献   

17.
A reduced specific absorption rate (SAR) version of the T(1rho)-weighted MR pulse sequence was designed and implemented. The reduced SAR method employs a partial k-space acquisition approach in which a full power spin-lock pulse is applied to only the central phase-encode lines of k-space, while the remainder of k-space receives a low-power spin-lock pulse. Acquisition of high- and low-power phase-encode lines are interspersed chronologically to minimize average power deposition. In this way, the majority of signal energy in the central portion of k-space receives full T(1rho)-weighting, while the average SAR of the overall acquisition can be reduced, thereby lowering the minimum safely allowable TR. The pulse sequence was used to create T(1rho) maps of a phantom, an in vivo mouse brain, and the brain of a human volunteer. In the images of the human brain, SAR was reduced by 40% while the measurements of T(1rho) differed by only 2%. The reduced SAR sequence enables T(1rho)-weighted MRI in a clinical setting, even at high field strengths.  相似文献   

18.
Proteoglycan (PG) depletion-induced changes in T1rho (spin-lattice relaxation in rotating frame) relaxation and dispersion in articular cartilage were studied at 4T. Using a spin-lock cluster pre-encoded fast spin echo sequence, T1rho maps of healthy bovine specimens and specimens that were subjected to PG depletion were computed at varying spin-lock frequencies. Sequential PG depletion was induced by trypsinization of cartilage for varying amounts of time. Results demonstrated that over 50% depletion of PG from bovine articular cartilage resulted in average T1rho increases from 110-170 ms. Regression analysis of the data showed a strong correlation (R2 = 0.987) between changes in PG and T1rho. T1rho values were highest at the superficial zone and decreased gradually in the middle zone and again showed an increasing trend in the region near the subchondral bone. The potentials of this method in detecting early degenerative changes of cartilage are discussed. Also, T(1rho)-dispersion changes as a function of PG depletion are described.  相似文献   

19.
PURPOSE: To develop a novel pulse sequence called spin-locked echo planar imaging (EPI), or (SLEPI), to perform rapid T1rho-weighted MRI. MATERIALS AND METHODS: SLEPI images were used to calculate T1rho maps in two healthy volunteers imaged on a 1.5-T Sonata Siemens MRI scanner. The head and extremity coils were used for imaging the brain and blood in the popliteal artery, respectively. RESULTS: SLEPI-measured T1rho was 83 msec and 103 msec in white (WM) and gray matter (GM), respectively, 584 msec in cerebrospinal fluid (CSF), and was similar to values obtained with the less time-efficient sequence based on a turbo spin-echo readout. T1rho was 183 msec in arterial blood at a spin-lock (SL) amplitude of 500 Hz. CONCLUSION: We demonstrate the feasibility of the SLEPI pulse sequence to perform rapid T1rho MRI. The sequence produced images of higher quality than a gradient-echo EPI sequence for the same contrast evolution times. We also discuss applications and limitations of the pulse sequence.  相似文献   

20.
PURPOSE: To develop a T1rho-prepared, balanced gradient echo (b-GRE) pulse sequence for rapid three-dimensional (3D) T1rho relaxation mapping within the time constraints of a clinical exam (<10 minutes), examine the effect of acquisition on the measured T1rho relaxation time and optimize 3D T1rho pulse sequences for the knee joint and spine. MATERIALS AND METHODS: A pulse sequence consisting of inversion recovery-prepared, fat saturation, T1rho-preparation, and b-GRE image acquisition was used to obtain 3D volume coverage of the patellofemoral and tibiofemoral cartilage and lower lumbar spine. Multiple T1rho-weighted images at various contrast times (spin-lock pulse duration [TSL]) were used to construct a T1rho relaxation map in both phantoms and in the knee joint and spine in vivo. The transient signal decay during b-GRE image acquisition was corrected using a k-space filter. The T1rho-prepared b-GRE sequence was compared to a standard T1rho-prepared spin echo (SE) sequence and pulse sequence parameters were optimized numerically using the Bloch equations. RESULTS: The b-GRE transient signal decay was found to depend on the initial T1rho-preparation and the corresponding T1rho map was altered by variations in the point spread function with TSL. In a two compartment phantom, the steady state response was found to elevate T1rho from 91.4+/-6.5 to 293.8+/-31 and 66.9+/-3.5 to 661+/-207 with no change in the goodness-of-fit parameter R2. Phase encoding along the longest cartilage dimension and a transient signal decay k-space filter retained T1rho contrast. Measurement of T1rho using the T1rho-prepared b-GRE sequence matches standard T1rho-prepared SE in the medial patellar and lateral patellar cartilage compartments. T1rho-preparedb-GRE T1rho was found to have low interscan variability between four separate scans. Mean patellar cartilage T1rho was elevated compared to femoral and tibial cartilage T1rho. CONCLUSION: The T1rho-prepared b-GRE acquisition rapidly and reliably accelerates T1rho quantification of tissues offset partially by a TSL-dependent point spread function.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号