首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Clinically, a reconstruction plate can be used for the facial repair of patients with mandibular segmental defects, but it cannot restore their chewing function. The main purpose of this research is to design a new three-dimensionally (3D) printed porous titanium mandibular implant with both facial restoration and oral chewing function reconstruction. Its biomechanical properties were examined using both finite element analysis (FEA) and in vitro experiments. Cone beam computed tomography images of the mandible of a patient with oral cancer were selected as a reference to create 3D computational models of the bone and of the 3D-printed porous implant. The pores of the porous implant were circles or hexagons of 1 or 2 mm in size. A nonporous implant was fabricated as a control model. For the FEA, two chewing modes, namely right unilateral molar clench and right group function, were set as loading conditions. Regarding the boundary condition, the displacement of both condyles was fixed in all directions. For the in vitro experiments, an occlusal force (100 N) was applied to the abutment of the 3D-printed mandibular implants with and without porous designs as the loading condition. The porous mandibular implants withstood higher stress and strain than the nonporous mandibular implant, but all stress values were lower than the yield strength of Ti-6Al-4V (800 MPa). The strain value of the bone surrounding the mandibular implant was affected not only by the shape and size of the pores but also by the chewing mode. According to Frost’s mechanostat theory of bone, higher bone strain under the porous implants might help maintain or improve bone quality and bone strength. The findings of this study serve as a biomechanical reference for the design of 3D-printed titanium mandibular implants and require confirmation through clinical investigations.  相似文献   

2.
Mechanical properties play a key role in the failure of dental implants. Dental implants require fatigue life testing before clinical application, but this process takes a lot of time. This study investigated the effect of various loading angles and implant lengths on the static fracture and fatigue life of dental implants. Implants with lengths of 9 mm and 11 mm were prepared. Static fracture tests and dynamic fatigue life tests were performed under three loading angles (30°, 40°, and 50°), and the level arm and bending moment were measured. After that, the fracture morphology and fracture mode of the implant were observed. The results showed that 9 mm length implants have a higher static failure load and can withstand greater bending moments, while 11 mm length implants have a longer fatigue life. In addition, as the loading angle increases, the static strength and bending moment decrease linearly, and the fatigue life shows an exponential decrease at a rate of three times. Increasing the loading angle reduces the time of the implant fatigue test, which may be an effective method to improve the efficiency of the experiment.  相似文献   

3.
The geometric shape of a dental implant plays an important role on the osteo-integration process. The purpose of this paper is to study the biomechanical behavior of different commercial dental implants and to analyse how thread profile may affect the stress concentration and distribution. Three different commercially-available dental implants were considered and acquired by means of a no-contact reverse engineering system. Stresses at bone–implant interface, in presence of perfect and not-perfect osteo-integration, were numerically evaluated by means of finite element (FEM) analyses applying occlusal and lateral loads. The results show more dangerous stresses at implant–bone interface in the case of not-perfect osteo-integration and stresses gradient enough uniform around the threads in the case of osteo-integration. In particular, the implant with the lowest thread-pitch exhibits the lowest bone damage. This confirms the crucial role of the geometric shape of the implant to reduce bone induced stresses and bone damage. The structural and functional connection between living bone and implant is a key issue in implantology field. When a guest device is installed in the living bone, many clinical responses may arise, such as inflammatory processes or osteo-integration failure. The results of this study can give useful information to understand the influence of the implant features and to appropriately apply it in the science of dental implants with the aim to reduce the potential implant failure.  相似文献   

4.
Background and objectives: The main purpose of this study was to evaluate the survival and success rates of dental implants with a double acid-etched surface treatment with evaluation times up to 10 years post-loading. Materials and Methods: This study was conducted at a hospital oral surgery and implantology unit. It included 111 dental implants with a double acid-etched surface. Three groups were created: Group 1 (1–3 years loading), Group 2 (3–5 years loading), and Group 3 (over 5 years loading). Probing depth, resonance frequency analysis (ISQ value), and marginal bone loss were evaluated. Results: The data obtained underwent statistical analysis. Overall, 78 patients were included in the study, who received, in total, 111 dental implants, all replacing single teeth. Mean probing depth was 3.03 mm and mean ISQ was 65.54. Regarding marginal bone loss, in Group 1, 67.6% of implants did not undergo any thread loss, in Group 2, 48.3%, and in Group 3, 59.6%; 59.10% of all implants did not present thread loss with a mean bone loss of 0.552 mm. The implant survival rate was 99.1%, and the success rate was 96.37%. Conclusions: Implants with a double acid-etched surface showed excellent success rates in terms of marginal bone loss, ISQ, and probing depth after up to 10 years of loading, making them a clinically predictable treatment option. Future studies are needed to compare this implant surface with other types in different restorative situations.  相似文献   

5.
Osseodensification is a new method of bone instrumentation for dental implant placement that preserves bulk bone and increases primary implant stability, and may accelerate the implant rehabilitation treatment period and provide higher success and survival rates than conventional methods. The aim of this retrospective study was to evaluate and discuss results obtained on immediate implant placement with immediate and delayed loading protocols under Osseodensification bone instrumentation. This study included private practice patients that required dental implant rehabilitation, between February 2017 and October 2019. All implants were placed under Osseodensification and had to be in function for at least 12 months to be included on the study. A total of 211 implants were included in the study, with a 98.1% total survival rate (97.9% in the maxilla and 98.5% in the mandible). For immediate implants with immediate load, 99.2% survival rate was achieved, and 100% survival rate for immediate implant placement without immediate load cases. A total of four implants were lost during this period, and all of them were lost within two months after placement. Within the limitations of this study, it can be concluded that Osseodensification bone instrumentation provided similar or better results on survival rates than conventional bone instrumentation.  相似文献   

6.
Dental implants’ success comprises their proper stability and adherence to different oral tissues (integration). The implant is exposed to different mechanical stresses from swallowing, mastication and parafunctions for a normal tooth, leading to the simultaneous mechanical movement and deformation of the whole structure. The knowledge of the mechanical properties of the bone and gingival tissues in normal and pathological conditions is very important for the successful conception of dental implants and for clinical practice to access and prevent potential failures and complications originating from incorrect mechanical factors’ combinations. The challenge is that many reported biomechanical properties of these tissues are substantially scattered. This study carries out a critical analysis of known data on mechanical properties of bone and oral soft tissues, suggests more convenient computation methods incorporating invariant parameters and non-linearity with tissues anisotropy, and applies a consistent use of these properties for in silico design and the application of dental implants. Results show the advantages of this approach in analysis and visualization of stress and strain components with potential translation to dental implantology.  相似文献   

7.
In thirteen different dental clinics in Singapore, Spain, Czech Republic and Italy, 504 patients were selected, and 483 dental implants were placed in maxillary sites after alveolar socket preservation (ASP) procedures with an autologous demineralized tooth extracted as graft material from an innovative Tooth Transformer device was obtained. All procedures used were reported in n°638 Ethical Committee surgical protocol of University of Chieti and approved. After 4 months, at dental implant placing, bone biopsies were performed to evaluate the histologic outcomes, and 12 months after implant loading, global implant survival rate, failure percentage and peri-implant bone loss were detected. After ASP, only 27 post-operative complications were observed and after 4 months, bone biopsy histomorphometric analysis showed a high percentage of bone volume (BV) 43.58 (±12.09), and vital new bone (NB) 32.38 (±17.15) with an absence of inflammation or necrosis areas. Twelve months after loading, only 10 dental implants failed (2.3%), with a 98.2% overall implant survival rate, nine cases showed mucositis (1.8%) and eight showed peri-implantitis (1.6%). At mesial sites, 0.43 mm (±0.83) of bone loss around the implants was detected and 0.23 mm (±0.38) at the distal sites with an average value of 0.37 mm (±0.68) (p > 0.568). Several studies with a longer follow-up will be necessary to confirm the preliminary data observed. However, clinical results seem to suggest that the post-extraction socket preservation procedure using innovative demineralized autologous tooth-derived biomaterial may be a predictable procedure to produce new vital bone able to support dental implant rehabilitation of maxilla edentulous sites.  相似文献   

8.
The present study was designed to compare the stress distributions in two restoration types of implants and the surrounding bone. The first restoration type was a conventional cement-retained zirconia crown, and the second was a novel cementless screw-retained zirconia crown with a base abutment. A three-dimensional finite element method was used to model the implants, restorations, and supporting bone. A comparative study of the two implants was performed under two masticatory loads: a vertical load of 100 N and a 30-degree oblique load of 100 N. Under both loading conditions, the maximum von Mises stress and strain values in the implant and supporting bone were higher in the conventional cement-retained restoration model than in the cementless screw-retained model. In terms of stress distribution, the cementless screw-retained zirconia crown with base abutment may be considered a superior restoration option compared to the conventional cement-retained zirconia crown.  相似文献   

9.
The choice of suitable materials and new designs in oral implantology and the subsequent enhancement of the characteristics of the dental implant developed is an important research topic with wide scope. The present work aims to develop a new multifunctional zirconia–ceria/alumina (Ce–TZP/Al2O3) composite with an antimicrobial glass-based coating to be used in multi-unit abutments compatible with commercially available Ti implants for peri-implantitis prevention. An airbrush spraying technique was effectively applied to coat the sintered ceramic composite starting from a glass powder suspension. This deposition technique was appropriate for obtaining continuous antimicrobial glass-based coatings with homogenous thickness (~35 µm) on ceramic dental implant components. The dental implant systems with the antimicrobial glassy coating were subjected to a mechanical integrity test following ISO 14801 to determine their long-term stability. The tested implant-coating structure seems to be stable under in vitro conditions with ultimate applied forces exceeding the maximum physiological occlusal loading force. This paper also presents a pilot clinical case report that shows peri-implant tissue around the mechanically stable glass coating with no signs of inflammation 1 year after implant insertion. This result is a preliminary probe of the durability and biological tolerance of the glassy material by the gingiva, as well as the antimicrobial effect on the peri-implant microbiota displayed by the coating.  相似文献   

10.
This work aimed to study one of the most important challenges in orthopaedic implantations, known as stress shielding of total shoulder implants. This problem arises from the elastic modulus mismatch between the implant and the surrounding tissue, and can result in bone resorption and implant loosening. This objective was addressed by designing and optimising a cellular-based lattice-structured implant to control the stiffness of a humeral implant stem used in shoulder implant applications. This study used a topology lattice-optimisation tool to create different cellular designs that filled the original design of a shoulder implant, and were further analysed using finite element analysis (FEA). A laser powder bed fusion technique was used to fabricate the Ti-6Al-4V test samples, and the obtained material properties were fed to the FEA model. The optimised cellular design was further fabricated using powder bed fusion, and a compression test was carried out to validate the FEA model. The yield strength, elastic modulus, and surface area/volume ratio of the optimised lattice structure, with a strut diameter of 1 mm, length of 5 mm, and 100% lattice percentage in the design space of the implant model were found to be 200 MPa, 5 GPa, and 3.71 mm−1, respectively. The obtained properties indicated that the proposed cellular structure can be effectively applied in total shoulder-replacement surgeries. Ultimately, this approach should lead to improvements in patient mobility, as well as to reducing the need for revision surgeries due to implant loosening.  相似文献   

11.
The study is aimed to virtually miniaturize medical implants produced of the biocompatible Ti with improved mechanical performance. The results on the simulation-driven design of medical implants fabricated of nanostructured commercially pure Ti with significantly enhanced mechanical properties are presented. The microstructure of initially coarse-grained Ti has been refined to ultrafine grain size by severe plastic deformation. The ultrafine-grained (UFG) Ti exhibits remarkably high static and cyclic strength, allowing to design new dental and surgical implants with miniaturized geometry. The possibilities to reduce the implant dimensions via virtual fatigue tests for the digital twins of two particular medical devices (a dental implant and a maxillofacial surgery plate) are explored with the help of finite element modeling. Additionally, the effect of variation in loading direction and the fixation methods for the tested implants are studied in order to investigate the sensitivity of the fatigue test results to the testing conditions. It is shown that the UFG materials are promising for the design of a new generation of medical products.  相似文献   

12.
Today, an interdisciplinary approach to solving the problems of implantology is key to the effective use of intraosseous dental implantations. The functional properties of restoration structures for the dentition depend significantly on the mechanical stresses that occur in the structural elements and bone tissues in response to mastication loads. An orthopedic design with a bar fixation system connected to implants may be considered to restore an edentulous mandible using an overdenture. In this study, the problem of the mechanics of a complete overdenture based on a bar and four implants was formulated. A mathematical model of the interaction between the orthopedic structure and jawbone was developed, and a methodology was established for the analytical study of the stress state of the implants and adjacent bone tissue under the action of a chewing load. The novelty of the proposed model is that it operates with the minimum possible set of input data and provides adequate estimates of the most significant output parameters that are necessary for practical application. The obtained analytical results are illustrated by two examples of calculating the equivalent stresses in implants and the peri-implant tissue for real overdenture designs. To carry out the final assessment of the strength of the implants and bone, the prosthesis was loaded with mastication loads of different localization. In particular, the possibilities of loading the prosthesis in the area of the sixth and seventh teeth were investigated. Recommendations on the configuration of the distal cantilever of the overdenture and the acceptable level and distribution of the mastication load are presented. It was determined that, from a mechanical point of view, the considered orthopedic systems are capable of providing long-term success if they are used in accordance with established restrictions and recommendations.  相似文献   

13.
Magnesium-Calcium (Mg-Ca) alloy has received considerable attention as an emerging biodegradable implant material in orthopedic fixation applications. The biodegradable Mg-Ca alloys avoid stress shielding and secondary surgery inherent with permanent metallic implant materials. They also provide sufficient mechanical strength in load carrying applications as opposed to biopolymers. However, the key issue facing a biodegradable Mg-Ca implant is the fast corrosion in the human body environment. The ability to adjust degradation rate of Mg-Ca alloys is critical for the successful development of biodegradable orthopedic implants. This paper focuses on the functions and requirements of bone implants and critical issues of current implant biomaterials. Microstructures and mechanical properties of Mg-Ca alloys, and the unique properties of novel magnesium-calcium implant materials have been reviewed. Various manufacturing techniques to process Mg-Ca based alloys have been analyzed regarding their impacts on implant performance. Corrosion performance of Mg-Ca alloys processed by different manufacturing techniques was compared. In addition, the societal and economical impacts of developing biodegradable orthopedic implants have been emphasized.  相似文献   

14.
The purpose of this study was to evaluate the effects of various fabrication techniques and materials used in implant-supported mandibular overdentures with a Hader bar attachment over added stress distribution. Three-dimensional geometric solid models, consisting of two implants (3.3 mm × 12 mm) placed at the bone level on both mandibular canine regions and a Hader bar structure, were prepared. Model 1 simulated a bar retentive system made from Titanium Grade 5 material by Computer Numerical Control (CNC) milling technique without using any converting adapter/multi-unit element on the implants, while Model 2 simulated the same configuration, but with converting adapters on the implants. Model 3 simulated a bar retentive system made from Cobalt-Chromium material, made by using conventional casting technique with converting adapters on the implants. Static loads of 100 Newton were applied on test models from horizontal, vertical and oblique directions. ANSYS R15.0 Workbench Software was used to compare Von Mises stress distribution and minimum/maximum principal stress values, and the results were evaluated by using Finite Element Analysis method. As a result, the highest stress distribution values under static loading in three different directions were obtained in Model 1. Stress was observed intensely around the necks of the implants and the surrounding cortical bone areas in all models. In scope of the results obtained, using converting adapters on implants has been considered to decrease transmission of forces onto implants and surrounding bone structures, thus providing a better stress distribution. It has also been observed that the type of material used for bar fabrication has no significant influence on stress values in those models where converting adapters were used.  相似文献   

15.
Corrosion of titanium dental implants has been associated with implant failure and is considered one of the triggering factors for peri-implantitis. This corrosion is concerning, because a large amount of metal ions and debris are generated in this process, the accumulation of which may lead to adverse tissue reactions in vivo. The goal of this study is to investigate the mechanisms for implant degradation by evaluating the surface of five titanium dental implants retrieved due to peri-implantitis. The results demonstrated that all the implants were subjected to very acidic environments, which, in combination with normal implant loading, led to cases of severe implant discoloration, pitting attack, cracking and fretting-crevice corrosion. The results suggest that acidic environments induced by bacterial biofilms and/or inflammatory processes may trigger oxidation of the surface of titanium dental implants. The corrosive process can lead to permanent breakdown of the oxide film, which, besides releasing metal ions and debris in vivo, may also hinder re-integration of the implant surface with surrounding bone.  相似文献   

16.
Dental implants with tapered conical connections are often combined with zirconia abutments for esthetics; however, the effect of the titanium base on the implant components remains unclear. This study evaluated the effects of a titanium base on the fracture resistance of zirconia abutments and damage to the tapered conical connection implants. Zirconia (Z) and titanium base zirconia (ZT) abutments were fastened to Nobel Biocare (NB) implants and Straumann (ST) implants and subjected to static load testing according to ISO 14801:2016. The experiments were performed with 3 mm of the platform exposed (P3) and no platform exposed (P0). The fracture loads were statistically greater in the titanium base abutments than the zirconia abutments for the NB and ST specimens in the P0 condition. In the P3 condition of the ST specimens, the deformation volume of the ZT group was significantly greater than the Z group. The titanium base increased the fracture resistance of the zirconia abutments. Additionally, the titanium base caused more deformation in the P3 condition. The implant joint design may also affect the amount of damage to the implants when under a load. The mechanical properties of the abutment should be considered when selecting a clinical design.  相似文献   

17.
The purpose of this study was to design porous implants with low stiffness and evaluate their biomechanical behavior. Thus, two types of porous implants were designed (Type I: a combined structure of diamond-like porous scaffold and traditional tapered thread. Type II: a cylindrical porous scaffold filled by arrayed basic diamond-like pore units). Three implant-supported prosthesis models were constructed from Type I, Type II and commercial implants (control group) and were evaluated by finite element analysis (FEA). The stress distribution pattern of the porous implants were assessed and compared with the control group. In addition, the stiffness of the cylindrical specimens simplified from three types of implants was calculated. The Type I implant exhibited better stress distribution than the Type II implant. The maximum stress between the cortical bone–Type I implant interface was 12.9 and 19.0% lower than the other two groups. The peak stress at the cancellous bone–Type I implant interface was also reduced by 16.8 and 38.7%. Compared with the solid cylinder, the stiffness of diamond-like pore cylinders simplified from the two porous implants geometry was reduced by 61.5 to 76.1%. This construction method of porous implant can effectively lower its stiffness and optimize the stress distribution at the implant–bone interface.  相似文献   

18.
(1) It is estimated that 10% of the world’s population will need a dental implant in their lifetime. Despite all the advances in the comprehension of dental implant designs, materials and techniques, traditional implants still have many limitations. Customized root-analogue implants are, therefore, gaining increased interest in dental rehabilitation and are expected to not only preserve more hard and soft tissues but also avoid a second surgery and improve patient overall satisfaction. In this sense, the aim of this review was to collect and analyse the clinical trials and case reports on customized root-analogue implants available in the literature; (2) This review was carried out according to the PRISMA Statement. An electronic database search was performed using five databases: PubMed, Google Scholar, Medline, Science Direct, and Scopus. The following keywords were used for gathering data: custom-made, dental implants, root-analogue, anatomical, customized and tooth-like; (3) 15 articles meeting the inclusion criteria—articles reporting clinical trials, case reports or animal studies and articles with root-analogue implants and articles with totally customized implant geometries—were selected for the qualitative synthesis. The design and manufacturing techniques, implant material and surface treatments were assessed and discussed; (4) The performance of some root-analogue implants with specific features (i.e., macro-retentions) was successful, with no signs of infection, periodontitis nor bleeding during the follow-up periods.  相似文献   

19.
The aim of this study was to evaluate the biomechanical impact, in terms of stress and displacement, at the level of a mandibular overdenture, on four mini dental implants (MDIs) after the loss of an implant. A three-dimensional virtual model was obtained by scanning the overdenture, and a biomechanical analysis was carried out, using the finite element method (FEM). The displacements of the overdenture and the equivalent von Mises stresses were evaluated using logarithmic scales. In the case of a mandibular overdenture on four MDIs inserted in the interforaminal area, the frontal loading generated the lowest values for the von Mises stresses, and the bilateral loading generated the least displacement when two implants were inserted in the canine area and two in the molar area. The highest von Mises stress was observed during frontal loading in the situation of the mandibular overdenture on four MDIs, two of which were inserted in the canine area and two in the molar area, following the loss of an implant in the canine area. The largest displacement was noted in the mandibular overdenture on four interforaminal MDIs during unilateral loading, following the loss of a distally inserted implant. The FEM analysis showed aspects that correlated with clinical observations, with predictive value. The concentration of von Mises stresses, and the occurrence of some displacements of the prosthodontic restoration, can explain the emergence of some complications in the overdenture’s biodynamics, and the increased risk of fracture. Complications can be prevented by choosing a certain number of implants and a topographical distribution correlated with biomechanical aspects, and by proposing a correct occlusal scheme with optimal functional loading.  相似文献   

20.
Despite high rates of osseointegration in healthy patients, complex cases present an increased risk of osseointegration failure when treated with dental implants. Furthermore, if immediate loading of the implants is used, maximizing the response of the host organism would be desirable. Anabolic steroids, such as Nandrolone Decanoate (ND), are reported to have beneficial clinical effects on various bone issues such as osteoporosis and bone fractures. However, their beneficial effects in promoting osseointegration in dental implant placement have not been documented. The study aimed to examine histological changes induced by ND in experimental dental implants in rabbit models. Two dental implants were placed in the tibias of 24 adult rabbits. Rabbits were allocated to one of two groups: control group or test group. Rabbits in the latter group were given nandrolone decanoate (15 mg/kg, immediately after implant placement and after 1 week). Micro-radiographic and histological analyses were assessed to characterize the morphological changes promoted by the nandrolone decanoate use. Total bone volume and fluorescence were significantly higher in the control group after 2 weeks. Such a difference between the two groups might indicate that, initially, nandrolone lengthens the non-specific healing period characteristic of all bone surgeries. However, after the beginning of the reparative processes, the quantity of newly formed bone appears to be significantly higher, indicating a positive stimulation of the androgen molecule on bone metabolism. Based on micro-radiology and fluorescence microscopy, nandrolone decanoate influenced bone regeneration in the implant site. The anabolic steroid nandrolone decanoate affects the healing processes of the peri-implant bone and therefore has the potential to improve the outcomes of implant treatment in medically complex patients.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号