首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Structures and bridges are being designed on the proposed and requested design lifetime of 50 to 100 years. In practice, one can see that the real lifetime of structures and bridges is shorter in many cases, in some special cases extremely shorter. The reasons for the lifetime shortening can be increased of the load cases (e.g., due to traffic on bridges, or due to other uses of a structure), using the material of lower quality, implementation of new standards and codes according to Eurocode replacing older ones. During the whole lifetime the structures must be maintained to fulfil the code requests. If the constructions are not able to fulfil the Ultimate Limit States (ULS) and the Serviceability Limit State (SLS), the structures or bridges have to be strengthened (whole or its elements). The purpose of the paper is the presentation of using a layer of the fibre concrete for a columns’ strengthening. Using the fibre reinforced concrete (FRC) of higher tensile strength makes it possible to increase the load-bearing capacity of the cross-section the column. The contact between the old concrete (core of column) and newly added layer (around column) is very important for using that method of strengthening. In the article, there is also a comparison of the surface modification methods.  相似文献   

2.
Research has focused on creating new methodologies such as supervised machine learning algorithms that can easily calculate the mechanical properties of fiber-reinforced concrete. This research aims to forecast the flexural strength (FS) of steel fiber-reinforced concrete (SFRC) using computational approaches essential for quick and cost-effective analysis. For this purpose, the SFRC flexural data were collected from literature reviews to create a database. Three ensembled models, i.e., Gradient Boosting (GB), Random Forest (RF), and Extreme Gradient Boosting (XGB) of machine learning techniques, were considered to predict the 28-day flexural strength of steel fiber-reinforced concrete. The efficiency of each method was assessed using the coefficient of determination (R2), statistical evaluation, and k-fold cross-validation. A sensitivity approach was also used to analyze the impact of factors on predicting results. The analysis showed that the GB and RF models performed well, and the XGB approach was in the acceptable range. Gradient Boosting showed the highest precision with an R2 of 0.96, compared to Random Forest (RF) and Extreme Gradient Boosting (XGB), which had R2 values of 0.94 and 0.86, respectively. Moreover, statistical and k-fold cross-validation studies confirmed that Gradient Boosting was the best performer, followed by Random Forest (RF), based on reduced error levels. The Extreme Gradient Boosting model performance was satisfactory. These ensemble machine learning algorithms can benefit the construction sector by providing fast and better analysis of material properties, especially for fiber-reinforced concrete.  相似文献   

3.
High-strength concrete is used to provide quality control for concrete structures, yet it has the drawback of brittleness. The inclusion of fibers improves the ductility of concrete but negatively affects the fresh properties of fiber-reinforced concrete. The effects of different fine to coarse aggregate ratios on the fresh and hardened properties of steel fiber reinforced concrete were investigated in this study. Mixtures were prepared with various fine to coarse aggregate (FA/CA) ratios incorporating 1% steel fiber content (by volume) at constant water to cement ratio. The workability, unit weight, and temperature of the concrete in the fresh state, and the mechanical properties of steel-fiber-reinforced concrete (SFRC) were investigated. The inclusion of fiber in concrete influenced the mobility of concrete in the fresh state by acting as a barrier to the movement of coarse aggregate. It was observed that the concrete with an FA/CA ratio above 0.8 showed better flowability in the fresh state, whilst an above 0.9 FA/CA ratio requires excessive superplasticizer to maintain the flowability of the mixtures. The compressive and flexural strength of SFRC increased with an increase in the FA/CA ratio by around 10% and 28%, respectively. Experimental values of compressive strength and flexural strength showed good agreement, however, modulus of elasticity demonstrated slightly higher values. The experimentally obtained measurements of the mechanical properties of SFRC conformed reasonably well with the available existing prediction equations, and further enabled establishing predictive isoresponse interactive equations within the scope of the investigation domain.  相似文献   

4.
Steel fibers are widely used because they can effectively improve the tensile, compressive and flexural properties of concrete structures. The selection of steel fiber dosage and aspect ratio at high temperature has an important impact on the flexural toughness of concrete components post-fire. In this paper, discussions are made on the simulated fire test in compliance with the ISO 834 standard to study the steel fiber-reinforced concrete (SFRC) components post-fire. The research reveals the influence of two commonly used steel fiber aspect ratios (50, 70) and steel fiber dosages (30 kg/m3, 40 kg/m3, 45 kg/m3) on the changes of the internal temperature field, the initial crack flexural strength and the flexural toughness of the SFRC components under a single-side fire. Moreover, combined with the four-point flexural test of the SFRC components post fire, the research also describes the damage of high temperatures to the flexural toughness of SFRC components, and suggests a calculation formula for SFRC thermal conductivity by way of the numerical inversion method. The results of this study have verified that the incorporation of steel fiber into concrete helps to reduce its internal thermal stress difference and improve the crack resistance and fire resistance of the concrete. Moreover, under high temperature conditions, the concrete component added with the steel fiber in an aspect ratio of 70 and a dosage of 45 kg/m3 increased their initial crack flexural strength by 56.8%, higher than that of plain concrete components, and the loss of equivalent flexural strength and flexural toughness of SFRC post fire was only 45.2% and 13.6%, respectively. The proposed calculation formula of thermal conductivity can provide a reference for a numerical simulation study of the temperature field of SFRC components in a high temperature environment.  相似文献   

5.
This study focuses on the dynamic compression performance of corroded steel fiber-reinforced concrete (SFRC) exposed to drying–wetting chloride cycles by a 37 mm diameter split Hopkinson pressure bar (SHPB) system. Three steel fiber contents (0.5%, 1.0%, 2.0%, by volume) were incorporated into concrete, and samples were subjected to drying–wetting cycles for different corrosion durations (30 days, 60 days, 90 days) after 28 days age. The sample damage mode, stress–strain curve and the dynamic compression performance of corroded SFRC were compared with plain concrete. Through the experimental data, strain-rate effect, fiber reinforcement effect and the corrosion duration influence on the impact compression property of SFRC were identified. The dynamic increase factor results of these samples were compared with the existing models in previous published literature. An empirical dynamic increase factor profile characterization model considering fiber content, corrosion duration and strain-rate is proposed.  相似文献   

6.
This study performed a scientometric-based examination of the literature on steel fiber-reinforced concrete (SFRC) to identify its key elements. Typical review papers are limited in their capacity to link distinct segments of the literature in an organized and systematic method. The most challenging aspects of current research are knowledge mapping, co-occurrence, and co-citation. The Scopus search engine was used to search for and obtain the data required to meet the goals of the study. During the data evaluation, the relevant publication sources, keyword assessment, productive authors based on publications and citations, top papers based on citations received, and areas vigorously involved in SFRC studies were recognized. The VOSviewer software tool was used to evaluate the literature data from 9562 relevant papers, which included citation, abstract, bibliographic, keywords, funding, and other information. Furthermore, the applications and constraints related to the usage of SFRC in the construction sector were examined, as well as potential solutions to these constraints. It was determined that only 17 publication sources (journals/conferences) had published at least 100 articles on SFRC up to June 2022. Additionally, the mostly employed keywords by authors in SFRC research include steel fibers, fiber-reinforced concrete, concrete, steel fiber-reinforced concrete, and reinforced concrete. The assessment of authors revealed that 39 authors had published at least 30 articles. Moreover, China, the United States, and India were found to be the most active and participating countries based on publications on SFRC research. This study can assist academics in building collaborative initiatives and communicating new ideas and techniques because of the quantitative and graphical depiction of participating nations and researchers.  相似文献   

7.
Aligning steel fibers is an effective way to improve the mechanical properties of steel fiber cementitious composites (SFRC). In this study, the magnetic field method was used to prepare the aligned hooked-end steel fiber cementitious composites (ASFRC) and the fracture behavior was investigated. In order to achieve the alignment of steel fibers, the key parameters including the rheology of the mixture and magnetic induction of electromagnetic field were theoretically analyzed. The results showed that, compared with SFRC, the cracking load and the ultimate load of ASFRC were increased about 24–55% and 51–86%, respectively, depending on the fiber addition content. In addition, the flexural tensile strength and residual flexural strength of ASFRC were found to increase up to 105% and 100%, respectively. The orientation of steel fibers also has a significant effect on energy consumption. The fracture energy of ASFRC was 56–70% greater than SFRC and the reinforcement effect of hooked-end steel fiber was higher than straight steel fiber. The fibers in the fracture surface showed that not only was the number of fibers of ASFRC higher than that of SFRC, but also the orientation efficiency factor of ASFRC was superior to SFRC, which explains the improvement of fracture behavior of ASFRC.  相似文献   

8.
The greatest weakness of concrete as a construction material is its brittleness and low fracture energy absorption capacity until failure occurs. In order to improve concrete strength and durability, silica fume SF is introduced into the mixture, which at the same time leads to an increase in the brittleness of concrete. To improve the ductility and toughness of concrete, short steel fibers have been incorporated into concrete. Steel fibers and silica fume are jointly preferred for concrete design in order to obtain concrete with high strength and ductility. It is well-known that silica fume content and fiber properties, such as aspect ratio and volume ratio, directly affect the properties of SFRCs. The mixture design of steel-fiber-reinforced concrete (SFRC) with SF addition is a very important issue in terms of economy and performance. In this study, an experimental design was used to study the toughness and splitting tensile strength of SFRC with the response surface method (RSM). The models established by the RSM were used to optimize the design of SFRC in terms of the usage of optimal silica fume content, and optimal steel fiber volume and aspect ratio. Optimum silica fume content and fiber volume ratio values were determined using the D-optimal design method so that the steel fiber volume ratio was at the minimum and the bending toughness and splitting tensile strength were at the maximum. The amount of silica fume used as a cement replacement, aspect ratio, and volume fraction of steel fiber were chosen as independent variables in the experiment. Experimentally obtained mechanical properties of SFRC such as compression, bending, splitting, modulus of elasticity, toughness, and the toughness index were the dependent variables. A good correlation was observed between the dependent and independent variables included in the model. As a result of the optimization, optimum steel fiber volume was determined as 0.70% and silica fume content was determined as 15% for both aspect ratios.  相似文献   

9.
The interface performance of steel fiber-reinforced concrete (SFRC) is a critical factor in determining mechanical properties and durability. The degradation of the concrete matrix and micro-structure interface is caused by environmental erosion, which shortens the service life of the structure design. Considering different volume contents of steel fiber (0%, 1%, 2%), the failure mechanism of SFRC under different environmental erosion conditions was studied through a laboratory test scheme. A total of six environmental factors are selected, including water, sodium chloride solution, sodium sulfate solution, dilute sulfuric acid solution, sodium hydroxide solution, and a freeze-thaw cycle. When subjected to different erosion concentrations and periods, micro-structure and axial bearing capacity deterioration laws are compared and analyzed. A durability equation related to fiber mixture ratio and strength is presented based on the experimental data and the numerical simulation method. The influence of different environments on steel fiber-reinforced concrete is analyzed, and the grey correlation degree of axial compressive strength is analyzed. The experimental results show that steel fiber can effectively improve the concrete axial bearing capacity, but different responses are observed under the various erosion conditions. A freeze-thaw cycle environment has the most significant impact on the axial compressive strength of concrete, followed by the sulfuric acid environment, and other environments have a weaker impact. The research results will provide a theoretical basis for predicting the performance deterioration of SFRC concerning other erosion conditions and periods.  相似文献   

10.
Fiber reinforcement is currently most often used in floors, railway sleepers, prefabricated structural elements such as slabs, beams and tanks, and in small architecture elements. Designing elements or structures made of fiber-reinforced concrete requires knowledge of its basic mechanical parameters. In the case of concretes with metallic fibers, the literature can find many tests and standard guidelines regarding compressive, flexural, tensile strength and fracture energy. The properties of concretes with non-metallic fibers are slightly less recognized, especially concretes with new types of polymer fibers. Additionally, the lack of standardized methods of testing concrete with polymer fibers make their application much more difficult. In the article, the possibility of using the EN 14651 standard to assess the flexural tensile strength of concrete with the addition of 2.0 and 3.0 kg/m3 of synthetic fibers with different geometry and form was presented. There was a 5.5–13.5% increase in the flexural tensile strength depending on the mixture type. Moreover, in the case of fiber-reinforced concretes, the ductility was enhanced and the samples were characterized by significant residual flexural tensile strengths. Additionally, from the workability tests it was concluded that after the incorporation of fibers, the consistency class decreased by one, two or three. Nevertheless, the compressive strengths of concrete with and without fibers were very similar to each other, and varied from 58.05 to 61.31 MPa. Moreover, it was concluded that results obtained from three-point bending tests significantly differed from empirical formulas for the calculation of the flexural tensile strength of fiber-reinforced concretes with dispersed steel fibers present in the literature. As a result, the new formula determined by the authors was proposed for concrete with polymer fibers with a nominal fiber content ≤1.0% and slenderness of up to 200. It must be mentioned that the formula gave a very good agreement with studies presented in different literature positions. In addition, an attempt was made to evaluate the strengths of tested mixes in accordance with the Model Code 2010. However, it occurred that the proposed fiber-reinforced concrete mixtures would not be able to replace traditional reinforcement in a form of steel bars. Furthermore, in uniaxial tensile tests, it was not possible to determine the σ–w graphs, and received results for maximum tensile strength did not show the clear influence of fibers incorporation on concrete. Then, the fracture energy enhancement (from about 16 to 22 times) and dependencies: crack mouth opening displacement–deflection; crack mouth opening displacement–crack tip opening displacement; and crack tip opening displacement–deflection were analyzed. Finally, the results from flexural tensile tests were compared with measurements of the surface displacement field obtained through the Digital Image Correlation technique. It was concluded that this technique can be successfully used to determine the crack mouth and crack tip opening displacements with very high accuracy.  相似文献   

11.
To address flexural fractures and predict fatigue life, an ordinary state-based peridynamic (PD) fatigue model is proposed for the initiation and propagation of flexural fractures. The key to this model is to replace the traditional partial differential fracture model with a spatially integral peridynamic model. Based on the contact and slip theory, the nonlocal peridynamic contact algorithm is confirmed and the load transfer is through the contact area. With the 3D peridynamic J-integration and the energy-based bond failure criterion, the peridynamic fatigue model for flexural cracks’ initiation and propagation is constructed. The peridynamic solid consists of a pair of gear contact surfaces and the formation and growth of flexural fatigue cracks evolved naturally over many loading cycles. The repeated load is transferred from the drive gear to the follower gear using the nonlocal peridynamic contact algorithm. The improved adaptive dynamic relaxation approach is used to determine the static solution for each load cycle. The fatigue bending crack angle errors are within 2.92% and the cycle number errors are within 10%. According to the experimental results, the proposed peridynamic fatigue model accurately predicts the location of the crack without the need for additional criteria and the fatigue life predicted by the simulation agrees quite well with the experimental results.  相似文献   

12.
This paper analyzes the efficiency of shrinkage reducing additives for the shrinkage deformations of ordinary Portland cement (OPC) concrete and its mechanical properties. OPC concrete was modified with an organic compound-based shrinkage reducing additive (SRA), quicklime, polypropylene fiber, and hemp fiber. It was found that a combination of 2.5% quicklime and 1.5% SRA led to the highest reduction in shrinkage deformations in concrete, and the values of shrinkage reached up to 40.0%. On the contrary, compositions with 1.5% SRA were found to have a significant reduction in compressive strength after 100 freeze-thaw cycles. Hemp fiber did not show a significant shrinkage reduction, but it is an environmentally friendly additive, which can improve OPC concrete flexural strength. Polypropylene fiber can be used in conjunction with shrinkage reducing additives to improve other mechanical properties of concrete. It was observed that 3.0 kg/m3 of polypropylene fiber in concrete could increase flexural strength by 11.7%. Moreover, before degradation, concrete with polypropylene fiber shows high fracture energy and decent residual strength of 1.9 MPa when a 3.5 mm crack appears. The tests showed a compressive strength decrease in all compositions with shrinkage reducing additives and its combinations after 28 days of hardening.  相似文献   

13.
Airport pavement concrete often suffers from freeze–thawing damage in high latitude and cold areas. In addition, the use of aircraft deicer makes the airport pavement concrete suffer from salt-freezing damage. To improve the durability of airport pavement concrete, modified polyester synthetic fiber (FC), cellulose fiber (CF), and basalt fiber (BF) reinforced concrete were prepared in this paper. The mechanical strength, pore structure, and frost resistance (freeze–thawing and salt freezing) of fiber-reinforced concrete were investigated. The effects of the combined action of fiber (fiber type and content) and surface treatment methods (spraying silane and impregnating silane) on the frost resistance of concrete were investigated. The results show that the flexural strength of concrete is positively correlated with the elastic modulus of fiber, but has little effect on the compressive strength. Fiber can reduce mass loss and dynamic modulus loss of concrete subjected to frost damage. FC more effectively improved the frost resistance of concrete than CF. After 30 cycles of salt freezing, the spalling amount of concrete sprayed or soaked with silane was decreased by 65.5% and 55.5%, respectively. Adding fiber and impregnating silane reduced the spalled concrete by up to 70.5%. Spraying silane treatment is better than impregnating silane treatment in enhancing the frost resistance of concrete because a better silane condensation reaction is achieved with spraying silane.  相似文献   

14.
This paper details the development and experimental assessment of a friction-type connector, designed to transfer shear flow between the top flange of a fiber-reinforced polymer (FRP) tub girder and a composite concrete deck for bridge applications. In contrast with previously used bearing-type connectors, this system relies on a deformed FRP surface to transfer shear via direct interlock with the concrete deck. The connector is materially efficient, simple to fabricate, can be used with lower-grade structural or stainless-steel fasteners, and provides a high degree of interface stiffness. Six compression-shear specimens were tested to assess the connector fatigue resistance and ultimate connection strength. Additionally, two short beam specimens were tested in three-point bending, one of which was subjected to fatigue loading. Based on the compression-shear tests and short beam tests, the connection exhibited strength exceeding that predicted by AASHTO for frictional concrete-concrete connections. The connection strengths were significantly greater than the factored demand required by AASHTO for a typical model FRP bridge girder. The cyclic loading of the connection in both compression-shear and beam bending showed that connection stiffness and strength do not significantly degrade, due to the application of 1 × 106 to 6 × 106 cycles of traffic-induced factored fatigue load.  相似文献   

15.
The influence of the compressive strength of concrete on fatigue resistance has not been investigated thoroughly and contradictory results can be found in the literature. To date, the focus of concrete fatigue research has been on the determination of the numbers of cycles to failure. Concerning the fatigue behaviour of high-strength concrete (HPC) and, especially, ultra-high-strength concrete (UHPC), which is described by damage indicators such as strain and stiffness development, little knowledge is available, as well as with respect to the underlying damage mechanisms. This lack of knowledge has led to uncertainties concerning the treatment of high-strength and ultra-high-strength concretes in the fatigue design rules. This paper aims to decrease the lack of knowledge concerning the fatigue behaviour of concrete compositions characterised by a very high strength. Within the priority programme SPP 2020, one HPC and one UHPC subjected to monotonically increasing and cyclic loading were investigated comparatively in terms of their numbers of cycles to failure, as well as the damage indicators strain and stiffness. The results show that the UHPC reaches a higher stiffness and a higher ultimate strain and strength than the HPC. The fatigue investigations reveal that the UHPC can resist a higher number of cycles to failure than the HPC and the damage indicators show an improved fatigue behaviour of the UHPC compared to the HPC.  相似文献   

16.
In this paper, the compressive behavior of fiber-reinforced concrete with end-hooked steel fibers has been investigated through a uniaxial compression test in which the variables were concrete compressive strength, fiber volumetric ratio, and fiber aspect ratio (length to diameter). In order to minimize the effect of specimen size on fiber distribution, 48 cylinder specimens 150 mm in diameter and 300 mm in height were prepared and then subjected to uniaxial compression. From the test results, it was shown that steel fiber-reinforced concrete (SFRC) specimens exhibited ductile behavior after reaching their compressive strength. It was also shown that the strain at the compressive strength generally increased along with an increase in the fiber volumetric ratio and fiber aspect ratio, while the elastic modulus decreased. With consideration for the effect of steel fibers, a model for the stress–strain relationship of SFRC under compression is proposed here. Simple formulae to predict the strain at the compressive strength and the elastic modulus of SFRC were developed as well. The proposed model and formulae will be useful for realistic predictions of the structural behavior of SFRC members or structures.  相似文献   

17.
Concrete tensile properties usually govern the fatigue cracking of structural components such as bridge decks under repetitive loading. A fatigue life reliability analysis of commonly used ordinary cement concrete is desirable. As fatigue is affected by many interlinked factors whose effect is nonlinear, a unanimous consensus on the quantitative measurement of these factors has not yet been achieved. Benefiting from its unique self-learning ability and strong generalization capability, the Bayesian regularized backpropagation neural network (BR-BPNN) was proposed to predict concrete behavior in tensile fatigue. A total of 432 effective data points were collected from the literature, and an optimal model was determined with various combinations of network parameters. The average relative impact value (ARIV) was constructed to evaluate the correlation between fatigue life and its influencing parameters (maximum stress level Smax, stress ratio R, static strength f, failure probability P). ARIV results were compared with other factor assessment methods (weight equation and multiple linear regression analyses). Using BR-BPNN, S-N curves were obtained for the combinations of R = 0.1, 0.2, 0.5; f = 5, 6, 7 MPa; P = 5%, 50%, 95%. The tensile fatigue results under different testing conditions were finally compared for compatibility. It was concluded that Smax had the most significant negative effect on fatigue life; and the degree of influence of R, P, and f, which positively correlated with fatigue life, decreased successively. ARIV was confirmed as a feasible way to analyze the importance of parameters and could be recommended for future applications. It was found that the predicted logarithmic fatigue life agreed well with the test results and conventional data fitting curves, indicating the reliability of the BR-BPNN model in predicting concrete tensile fatigue behavior. These probabilistic fatigue curves could provide insights into fatigue test program design and fatigue evaluation. Since the overall correlation coefficient between the prediction and experimental results reached 0.99, the experimental results of plain concrete under flexural tension, axial tension, and splitting tension could be combined in future analyses. Besides utilizing the valuable fatigue test data available in the literature, this work provided evidence of the successful application of BR-BPNN on concrete fatigue prediction. Although a more accurate and comprehensive method was derived in the current study, caution should still be exercised when utilizing this method.  相似文献   

18.
The excellent overall performance of polyoxymethylene (POM) fiber enables it to show great potential for engineering applications. The effect of POM fibers on the dynamic compression mechanical properties of concrete is an important issue for its application in engineering structures such as airport pavement and bridges. It is necessary to investigate the dynamic compressive mechanical properties of POM-fiber-reinforced concrete (PFRC) under impact loading. The PFRC specimens with various POM fiber lengths (6, 8, 12, 16, and 24 mm) and ordinary-performance concrete (OPC) specimens were tested by utilizing the split Hopkinson pressure bar (SHPB). We studied the effect of fiber length and strain rate on the dynamic compression mechanical properties of PFRC and established a damage dynamic constitutive model for PFRC. The results indicate that the dynamic compressive strength, peak strain, ultimate strain, dynamic peak toughness, dynamic ultimate toughness, and dynamic increase factor (DIF) of the PFRC increased obviously with the increase in strain rate. POM fiber was found to be able to effectively improve the deformation ability and impact toughness of concrete. The dynamic compressive strength and impact toughness of PFRC with a fiber length of 8 mm was optimal at different strain rates. The POM fibers with 16 mm and 24 mm lengths negatively affected the dynamic compressive strength of the concrete. The fiber length variation had an insignificant effect on the DIF of PFRC. The established damage dynamic constitutive model for PFRC was fitted and analyzed, and it was found that the model is able to describe the dynamic characteristics of PFRC well. This study can extend POM fibers to engineering structures that may be subjected to impact loading and act as a reference for the design of PFRC under impact loading.  相似文献   

19.
The main objective of this study is to better understand the performance changes of naturally aged glass fiber-reinforced concrete (GFRC) and polypropylene fiber-reinforced concrete (PPFRC), especially the degradation of fibers, which is of great significance for evaluating the durability of structures using these two types of composite materials. The mechanical properties, water absorption, and microstructures of GFRC and PPFRC at a curing age of three years, including their compressive strength, full curves of water absorption, fiber-matrix interaction, and fiber degradation, were systematically studied, and the related properties were compared with those at the curing age of 28 days. The degradation of fibers after freeze-thaw cycles was also studied. The results revealed the following. The water/binder ratio (w/b) affects the rate of increase of the long-term compressive strength of naturally aged concrete. In general, the water absorption of fiber-reinforced concrete (FRC) at the curing age of three years was found to be significantly reduced, but with the increases of w/b and the fiber content to the maximum values, the water absorption of the specimens cured for three years was higher than that of the specimens cured for 28 days. Moreover, with the increase of the curing age, the optimal glass fiber (GF) contents for reducing the water absorption decreased from 1.35% to 0.90% (w/b = 0.30), and from 0.90% to 0.45% (w/b = 0.35), respectively. The GF surface was degraded into continuous pits with diameters of about 200 to 600 nm, and the surface of the pits was attached with spherical granular C-S-H gel products with diameters of about 30 to 44 nm. The freeze-thaw cycles were found to have no significant effect on the pits on the GF surface and the granular C-S-H gel products attached to the pits, but caused a portion of the cement matrix covering the GF to fall off. The interfacial bonding between the polypropylene fiber (PPF) and the cement matrix exhibited almost no change in the PPFRC after three years of curing as compared with that after 28 days of curing. Furthermore, the cement hydration gel on the PPF surface was not significantly damaged by 150 freeze-thaw cycles.  相似文献   

20.
This study investigated the fatigue crack propagation behavior of ultra-high-performance concrete (UHPC) incorporated with different steel fiber lengths of 6, 13, and 20 mm under flexural cyclic loading, based on the Paris law and nonlinear fracture mechanics. In addition, multiple crack covering areas and fatigue J-integral amplitudes were employed to quantitatively evaluate the fatigue crack propagation rate and predicate the fatigue life of the UHPC during the steady development stage. The results indicated that the maximum crack opening displacement (COD) values were 0.312, 0.673, and 1.265 mm and the minimum crack growth rates were −3.05, −4.48 and −4.62 for SF6, SF13, and SF20, respectively. The critical crack length was approximately 65 mm for UHPC specimens containing different fiber length at a given fiber volume fraction (2.0%), indicating that the critical crack length was simply related to the fiber length. Interestingly, when the fatigue crack area of all the tested series reached approximately 35 mm2, fracture failure occurred. There were very small predictions between the actual tested and predicated fatigue lives, all less than 7.21%. Hence, it was reasonable to predict the fatigue life of the UHPC based on the J-integral according to the DIC technique.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号