首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Purpose: To describe the findings of hyperperfusion on perfusion computed tomography (CT) in four patients following revascularization for acute stroke.

Material and Methods: In 2002-2003, among a series of 6 patients presenting with an acute stroke and treated with intra-arterial thrombolysis, we observed the presence of hyperperfusion in 3 patients on the follow-up CT perfusion. We included an additional patient who was treated with intravenous thrombolysis and who had hyperperfusion on the follow-up CT perfusion. We retrospectively analyzed their CT perfusion maps. Cerebral blood volume (CBV) and cerebral blood flow (CBF) maps were compared between the affected territory and the normal contralateral hemisphere.

Results: In the four patients, the mean CBV and CBF were 3.6±2.0 ml/100 g and 39±25 ml/100 g/min in the affected territory compared to the normal side (mean CBV = 2.7±2.1 ml/100 g, mean CBF = 27±23 ml/100 g/min). There was no intracranial hemorrhage in the hyperperfused territories. At follow-up CT, some hyperperfused brain areas progressed to infarction, while others retained normal white to gray matter differentiation.

Conclusion: CT perfusion can demonstrate hyperperfusion, which can be seen in an ischemic brain territory following recanalization.  相似文献   

2.
Purpose: To investigate whether improvements in signal-to-noise ratio (SNR) and spectral resolution are found in spectra from patients with brain metastases obtained at higher magnetic field strengths using standard clinical instrumentation.

Material and Methods: Six patients with brain metastases, 13 healthy volunteers, and a phantom containing brain metabolites were examined using two clinical MR instruments operating at 1.5T (Siemens) and 3T (Philips) with standard clinical head coils. Spectra were obtained using a point resolved spectroscopy pulse sequence, echo times (TE) 32 ms and 144 ms, and repetition time 2000 ms from a volume-of-interest (VOI) of size 15×15×15 mm3. SNR and spectral resolution of the metabolites N-acetylaspartate, choline, and creatine compounds in spectra from 3T were compared to the 1.5T spectra.

Results: In general, spectral resolution was improved by 25-30% at higher magnetic field strength. Only minor improvements in SNR were obtained at 3T using short echo time and 20-50% at long echo time.

Conclusion: SNR and spectral resolution were improved at higher magnetic field strength, especially with TE 144 ms, including spectra from patients with heterogeneous brain tumors. However, differences in the defined effective VOI, particularly at short echo time, reduced the expected effect of increased magnetic field strength on the measured SNR.  相似文献   

3.
Background: Multidetector computed tomography (MDCT) enterography combines neutral enteric contrast with intravenously administered contrast material. The optimal intravenous (IV) contrast material protocol has still not been established.

Purpose: To determine the optimal delay time to image patients with small-bowel Crohn's disease during MDCT enterography.

Material and Methods: After oral administration of 1350 ml of neutral contrast medium, 26 patients with small-bowel Crohn's disease underwent MDCT enterography; scans were obtained 40 s (enteric phase) and 70 s (parenchymal phase) after IV administration of 100 ml of iodinated contrast material. Three radiologists, blinded to clinical and pathological findings, independently and retrospectively evaluated each scan in two separate reading sessions for the presence or absence of CT features of Crohn's disease activity. The interobserver agreement was evaluated, and the efficacy of each phase in detecting active disease in the terminal ileum for each reader was determined. The gold standard was pathology (n = 13), endoscopy (n = 3), and clinical evaluation (n = 10).

Results: No statistically significant difference was present between the enteric and the parenchymal phase for each reader in each segment regarding the presence or absence of CT features of Crohn's disease. The interobserver agreement for the presence of five main features of active Crohn's disease in the terminal ileum ranged from poor to excellent. The sensitivity, specificity, negative predictive value, positive predictive value, and accuracy for active Crohn's disease in the terminal ileum ranged from 40 to 90%, 88 to 100%, 70 to 94%, 44 to 100%, and 69 to 96%, respectively. There was no statistical difference between the two phases for each reader.

Conclusion: MDCT enterography in patients with suspected active Crohn's disease can be obtained at either 40 s or 70 s after IV contrast material.  相似文献   

4.
Background: A method to describe pelvic rotations between pairs of standard sequential pelvic anteroposterior radiographs based on a pelvic phantom is described in a former study.

Purpose: To expand this method into clinical use based on clinical data.

Material and Methods: Teardrop distances were measured on 262 pelvic radiographs from 46 patients in a clinical material using a computer program designed to perform measurements on digital radiographs. Anthropometric data recorded from 141 pelvises in an anatomical collection were employed in a computer program designed to simulate radiographs of virtual objects. Virtual rotations of the pelvises were carried out with 4653 virtual radiographs obtained. Virtual radiographic measures were analyzed.

Results: A statistically significant difference of 8 mm between mean teardrop distance in females (120 mm) and males (112 mm) was found in the clinical material. A set of formulas describing the relations between differences of two rotation ratios and pelvic rotations were derived. Four simple regression analyses were carried out with the use of virtual measures. Adjusted teardrop distances were implemented.

Conclusion: A clinical method to describe pelvic rotations using standard pelvic radiographs was developed.  相似文献   

5.
Background: Contrast-induced nephropathy (CIN) is a serious complication of the use of iodinated contrast media (CM), and is associated with increased morbidity and mortality.

Purpose: To investigate whether radiologists take sufficient measures to prevent CIN in computed tomography (CT).

Material and Methods: 2005 survey of 509 European radiologists who had ≥3 years' experience and performed ≥50 CT scans/week.

Results: The most common methods used to identify patients at risk of CIN were renal function measurements (64%), clinical judgment (55%), and patient questionnaires (31%); 9% made no routine attempt to identify at-risk patients. The most common preventive protocols used in at-risk patients included: intravenous (i.v.) saline volume repletion (59%) or oral hydration (52%) before/after CT; use of low-osmolar CM (LOCM; 40%) or isosmolar CM (IOCM; 36%); and N-acetylcysteine (20%); 8% used no hydration regimen. While 78% of respondents used ≤100 ml of CM in high-risk patients, 14% used ≤150 ml, and 9% set no volume limit. For 57% of respondents, osmolality was the most important attribute in choosing an iodinated CM in at-risk patients; 41% agreed that CIN risk is lower with IOCM versus LOCM (31% disagreed).

Conclusion: A European radiologist survey identified a need for increased implementation of evidence-based protocols to improve CIN prevention: routine identification of at-risk patients; withdrawal of nephrotoxic drugs; use of volume repletion regimens; lowest possible volume of CM; and appropriate CM.  相似文献   

6.
Purpose: To evaluate the angiographic findings of patients who have inadvertently injected oral formulations of drugs into an upper extremity artery.

Material and Methods: The radiology files for the previous 4 years were analyzed retrospectively. Seven patients were referred from the Emergency Department for angiography and possible thrombolysis during that time period.

Results: The worst clinical results were found among the patients whose angiographic examinations showed absent flow. Two patients who were treated with local thrombolysis had no better results compared to the other five patients.

Conclusion: Findings of delayed flow and absent flow in angiography should lead to intensified conservative treatment, especially among patients who have clinical findings of delayed capillary refilling or/and impaired muscular strength.  相似文献   

7.
Background: Portal vein embolization (PVE) is now widely accepted as a useful preoperative procedure in selected patients undergoing extended hepatectomy. However, the effect of PVE on the growth of liver tumors has not been fully elucidated.

Purpose: To retrospectively evaluate the effects of PVE on the growth of liver tumors in the embolized lobes.

Material and Methods: Eight patients with a primary liver tumor, six hepatocellular carcinomas (HCC) and two cholangiocellular carcinomas (CCC), were studied. The growth rates of the tumors in the embolized lobes and non-embolized liver parenchyma were calculated using the computed tomography (CT) volume values at the time of tumor identification, and before and after PVE.

Result: The median tumor growth rate was 0.59 cm3/day (range 0.22-6.01 cm3/day) before PVE and 2.37 cm3/day (range 0.29-13.97 cm3/day) after PVE (P = 0.018). The tumor growth acceleration ratios ranged from 1.50 to 7.46 (median 2.65) in the six HCCs, and were 1.00 and 1.32 in the two CCCs. There was no apparent correlation between the tumor growth rate after PVE and the growth rate of non-embolized liver parenchyma (median 6.00 cm3/day, range 1.24-11.0 cm3/day).

Conclusion: Liver tumor growth in an embolized lobe accelerates after PVE, in patients with HCC.  相似文献   

8.
Background: Detection of colorectal tumors with computed tomography colonography (CTC) is an alternative to conventional colonoscopy (CC), and clarification of the diagnostic performance is essential for cost-effective use of both technologies.

Purpose: To evaluate the diagnostic performance of CTC compared with CC.

Material and Methods: 231 consecutive CTCs were performed prior to same-day scheduled CC. The radiologist and endoscopists were blinded to each other's findings. Patients underwent a polyethylene glycol bowel preparation, and were scanned in prone and supine positions using a single-detector helical CT scanner and commercially available software for image analysis. Findings were validated (matched) in an unblinded comparison with video-recordings of the CCs and re-CCs in cases of doubt.

Results: For patients with polyps ≥5 mm and ≥10 mm, the sensitivity was 69% (95% CI 58-80%) and 81% (68-94%), and the specificity was 91% (84-98%) and 98% (93-100%), respectively. For detection of polyps ≥5 mm and ≥10 mm, the sensitivity was 66% (57-75%) and 77% (65-89%). A flat, elevated low-grade carcinoma was missed by CTC. One cancer relapse was missed by CC, and a cecal cancer was missed by an incomplete CC and follow-up double-contrast barium enema.

Conclusion: CC was superior to CTC and should remain first choice for the diagnosis of colorectal polyps. However, for diagnosis of lesions ≥10 mm, CTC and CC should be considered as complementary methods.  相似文献   

9.
Background: A matter of substantial concern regarding all needle biopsy techniques is seeding along the biopsy needle tract.

Purpose: To assess cell seeding along the needle tract of vacuum-assisted breast biopsy (VABB).

Material and Methods: The study included 21 patients with ductal carcinoma in situ (DCIS) and 10 patients with invasive ductal carcinoma (IDC) diagnosed by VABB for nonpalpable mammographic lesions. VABB (11G, on a Fischer table) was performed, and the duration of the procedure was measured. After surgery, the whole needle tract was embedded in paraffin blocks, stained with hematoxylin-eosin, and examined by a pathologist.

Results: Cases with dissemination of cancer cells in the needle tract were not observed (one-sided 97.5% CI 0-10.0%). In 2/31 (6.5%) cases (95% CI 0.8-21.4%), benign epithelial cell displacement was observed, and the duration of VABB was significantly longer in these two cases (52.5±3.5 min vs. 42.0±4.4 min for cases without benign cell displacement; P = 0.018, Mann-Whitney-Wilcoxon test for independent samples).

Conclusion: No displacement of malignant cells within the 11G needle tract was documented. Benign cell displacement was associated with longer VABB duration. The phenomenon of tumor cell dissemination along the needle tract is of questionable clinical significance when the treatment guidelines are followed.  相似文献   

10.
Background: Vacuum-assisted devices are becoming a useful tool in the diagnosis and treatment of breast pathology. Recent publications show good results in percutaneous removal of benign lesions.

Purpose: To discuss our experience in percutaneous excision of ductal lesions with a vacuum-assisted, ultrasound-guided directional system.

Material and Methods: From January 2003 to July 2006, 63 patients with pathological nipple discharge and intraductal lesion identifiable on imaging were studied at two reference centers. Percutaneous excision with a vacuum-assisted device was offered as an alternative to surgery.

Results: A total of 71 lesions were diagnosed in 63 patients with a mean age of 52 years. All the patients presented nipple discharge. Mammography was normal in 65 cases (92%). Galactography showed an intraductal lesion in 67 cases (94%). Mean lesion size on ultrasonography was 7.4 mm (2-26 mm). Percutaneous excision was performed in 45 lesions (63%), while surgical excision was indicated in 26 lesions. The histopathological results in the 45 lesions biopsied demonstrated intraductal papilloma in 30 cases, dilated duct with papillomatous projections in 11, ductal ectasia with no papillary lesion in three, and a nonspecific benign result in one. Excision was considered complete in 41 lesions (91%). Clinical signs of discharge were resolved in 39 patients (95% of cases treated percutaneously). Mild complications occurred in four cases.

Conclusion: Percutaneous excision of ductal lesions with an ultrasound-guided, vacuum-assisted device is a safe procedure with high diagnostic and therapeutic value for the management of breast discharge.  相似文献   

11.
Purpose: To report the association between hepatocellular carcinoma (HCC) and hepatic focal nodular hyperplasia (FNH) and the possible impact on clinical decision-making with regard to resective approaches in patients with FNH.

Material and Methods: We retrospectively analyzed the findings in 77 adult patients who underwent liver resections for FNH between October 1989 and September 2001 at our center. HCC within the confines of FNH was found in two patients. We demonstrate the magnetic resonance imaging (MRI) and macroscopic and microscopic findings.

Results: Presurgical MRI demonstrated heterogeneous signal characteristics of moderately hyperintense FNH on T2-weighted images and, after IV administration of super-paramagnetic iron oxide particles, HCC in FNH was barely delineable. Both patients underwent successful right hemihepatectomy to remove the suspicious FNH with diameters of 12 and 14 cm; intralesional HCC diameters were 3 and 5 cm, respectively. Patients could be rapidly dismissed. However, one patient died after recurrence of HCC 1.5 years after surgery, whereas the other patient continues tumor-free 4 years after surgery. Alpha-feto-protein was normal in both patients.

Conclusion: In FNH with rapid growth tendency and heterogenic MR appearance, surgical removal should be considered to overcome the risk of inadequate therapy in the very rare group of patients with HCC in association with FNH.  相似文献   

12.
Background: Recent concepts about cerebrospinal fluid (CSF) circulation in communicating hydrocephalus (CoHy), which is also termed “restricted arterial pulsation hydrocephalus,” suggest reduced arterial pulsations of subarachnoid vessels with a smaller amount of CSF shifted in subarachnoid spaces during the early systole. The postulated restriction of subarachnoid arterial pulsations in CoHy should induce a smaller motion artifact and reduced local stream effects in CSF in magnetic resonance (MR) diffusion-weighted imaging (DWI).

Purpose: To investigate the maximum diffusivity in CSF in patients with and without CoHy using DWI.

Material and Methods: 12 patients without CSF circulation disturbances and six cases with proven CoHy were assessed. Diffusion was measured in six noncollinear directions without triggering the arterial pulse wave (scan time 6:45 min, voxel size 2×2×2 mm). Due to expected artifacts, the calculated maximum diffusivity was called apparent diffusivity. Regional high and low apparent diffusivity was assessed in CSF spaces on newly created 3D CSF motion maps.

Results: Patients with regular CSF circulation exhibited high apparent diffusivity in CSF in basal subarachnoid spaces, whereas apparent diffusivity was low there in patients with CoHy.

Conclusion: DWI opens a feasible approach to study CSF motion in the neurocranium. Restricted arterial pulsations seem to be involved in CoHy.  相似文献   

13.
Purpose: To investigate the prevalence of renal artery aneurysms, and to assess the value of multidetector-row computed tomography (MDCT) in diagnosing renal artery aneurysms.

Material and Methods: Altogether, 862 patients underwent arterial-phase contrast-enhanced CT scan of the abdomen in the period November 2003 to October 2005. A search for renal artery aneurysms was performed in our reporting system and revealed six patients with renal artery aneurysm (RAA).

Results: The incidence of RAA was 0.7%. All renal artery aneurysms were solitary, located in the main trunk or the first branch of the renal artery, with sizes from 1.5 cm to 3.4 cm. Five aneurysms were saccular, one fusiform. No underlying thrombosis was seen. Extensive calcification was found in one aneurysm. Three aneurysms were diagnosed using axial images, while three aneurysms were only displayed by volume rendering and maximum-intensity projection images.

Conclusion: This study demonstrates a 0.7% incidence of renal artery aneurysms in a total of 862 patients. MDCT has an important role in detecting and assessing renal artery aneurysms. Some aneurysms can only be displayed by post-processing techniques such as volume rendering and maximum-intensity projection.  相似文献   

14.
Background: Hepatic microcirculation is a main determinant of reperfusion injury and graft quality in liver transplantation. One of the important diagnostic procedures to recognize reperfusion failure is contrast-enhanced computed tomography or magnetic resonance imaging.

Purpose: To examine the additional effect of contrast media (iomeprol and gadopentetate dimeglumine) on hepatic microcirculation and hepatic cellular damage in the phase of early ischemia/reperfusion injury of the rat liver.

Material and Methods: The partial warm ischemia-reperfusion injury model of rat liver was used. Microcirculation and leukocyte-endothelium interaction were measured by intravital microscopy. Hepatic cellular damage was indicated by liver enzyme activity in the sera. The evaluation parameters were measured at baseline and at 30, 60, and 90 min after reperfusion. The contrast media (iomeprol group, n = 6; gadopentetate dimeglumine group, n = 6) or Ringer's solution (control group, n = 8) were applied after 30 min of reperfusion.

Results: No additional injury to the ischemia/reperfusion injury of the liver after intravenous application of radiographic contrast media was found. Some protective effect was even recorded after application of iodinated contrast media.

Conclusion: The use of contrast media during diagnostic procedure of the liver seems to be relatively safe, even in the stage of early reperfusion after liver transplantation.  相似文献   

15.
Purpose: To evaluate the biliary enhancement dynamics of the two gadolinium chelates Gd-BOPTA (MultiHance®) and Gd-EOB-DTPA (Primovist®) in normal healthy subjects.

Material and Methods: Ten healthy volunteers were evaluated with both agents by magnetic resonance (MR) imaging at 1.5T using a breath-hold gradient-echo T1-weighted VIBE sequence. The relative signal intensity (SI) differences between the common hepatic duct (CHD) and liver parenchyma were measured before and 10, 20, 30, 40, 130, 240, and 300 min after contrast medium injection.

Results: Biliary enhancement was obvious 10 min post-injection for Gd-EOB-DTPA and was noted at 20 min for Gd-BOPTA. At 40 min delay, Gd-BOPTA reached its peak biliary enhancement, but at neither 30 nor 40 min delay was there any significant difference compared with that of Gd-EOB-DTPA. At later delays, the contrast between CHD and liver continued to increase for Gd-EOB-DTPA, whereas it decreased for Gd-BOPTA.

Conclusion: The earlier onset and longer duration of a high contrast between CHD and liver for Gd-EOB-DTPA facilitates examination of hepatobiliary excretion. Therefore, Gd-EOB-DTPA may provide adequate hepatobiliary imaging within a shorter time span than Gd-BOPTA and facilitate scheduling at the MR unit. Further studies in patients are required to compare the imaging advantages of Gd-EOB-DTPA and Gd-BOPTA in clinical practice.  相似文献   

16.
Purpose: To compare radiation doses given to patients undergoing IVU (intravenous urography) before and after digitalization of our X-ray department.

Material and Methods: IVU examinations were monitored with dose area product meters before and after the X-ray department changed to digital techniques. The first step was a change from film-screen to storage phosphor plates, while the second step involved changing to a flat panel detector. Forty-two patients were included for the film-screen situation, 69 when using the storage phosphor plates, and 70 using the flat panel detector.

Results: A dose reduction from 41.8 Gycm2 to 31.5 Gycm2 was achieved with the first step when the film-screen system was replaced with storage phosphor plates. A further reduction to 12.1 Gycm2 was achieved using the flat panel detector.

Conclusion: The introduction of the flat panel detectors made a considerable dose reduction possible.  相似文献   

17.
Purpose: To determine the effects of detector configuration, as well as vessel orientation, on the depiction accuracy of arterial stenosis using four-channel multidetector-row helical computed tomography (MDCT) angiography in vitro.

Material and Methods: Five acrylic vessel phantoms (3 mm in diameter with 25 or 50% stenosis, or 5 mm with 25, 50, or 75% stenosis) were scanned with a four-channel MDCT scanner at five vessel orientations (0, 30, 45, 60, and 90° to the z-axis) using 4×1.25, 2.5, 3.75, and 5.0-mm detector configurations at beam pitches of 0.75 and 1.5. The percentage of stenosis was calculated by the ratio of the full width at half maximum for stenotic and non-stenotic portions of the phantom, and compared to the actual known values.

Results: A detector configuration of 4×1.25 mm provided good reproducibility, as well as high accuracy for assessing vessel stenosis, while a 4×2.5-mm or wider detector configuration caused underestimations of stenosis. Although the phantoms perpendicular to the z-axis were underestimated, the errors were kept in clinically acceptable ranges using the 4×1.25-mm detector configuration.

Conclusion: Four-channel MDCT accurately discerns stenosis for vessel phantoms of 3 or 5 mm in diameter at any orientation when using a detector configuration of 4×1.25 mm.  相似文献   

18.
Purpose: To evaluate if two gadolinium perfusion studies can be performed during the same table occupancy without degradation of the derived data in the second study.

Material and Methods: Magnetic resonance (MR) perfusion studies of the whole brain were performed on 12 patients during the administration of two gadolinium boluses separated by 8 min. In six patients, gadolinium was given as two 20-ml administrations of standard 0.5 M chelate (Magnevist), whilst the other six patients received two 10-ml administrations of 1.0 M chelate (Gadovist).

Results: There were no significant differences in subjective quality between the time-intensity curves of the first and second perfusion studies using either the 0.5 M or 1.0 M gadolinium chelate. The objective measurements in quality of the time-intensity curves (maximum signal change and full width at half maximum) changed by less than 5% of the original values on the second perfusion study. The first-moment mean transit times did not change significantly on the sequential studies. The regional cerebral blood volume tended to increase on the second study (by 15% on average), but this did not reach statistical significance.

Conclusion: The results from two sequential dynamic gadolinium-based perfusion studies can be compared in a meaningful manner using the technique described.  相似文献   

19.
Purpose: To evaluate fat-suppressed (FS) proton-density-weighted (PDw) turbo spin-echo (TSE) magnetic resonance imaging (MRI) compared to arthroscopy in the detection of meniscal lesions.

Material and Methods: In a prospective study, 31 knee joints were imaged on a 1.5T MR scanner before arthroscopy using the following sequences: (a) coronal and sagittal FS-PDw TSE (TR/TE: 4009/15 ms); (b) coronal T1w SE (TR/TE: 722/20 ms), and sagittal PDw TSE (TR/TE: 3800/15 ms). Other imaging parameters were: slice thickness 3 mm, FOV 160 mm, matrix 256×256. A total of 186 meniscal regions (62 menisci; anterior horn, body, posterior horn) were evaluated. Standard of reference was arthroscopy. Sensitivity, specificity, negative predictive value (npv), positive predictive value (ppv), and accuracy were calculated.

Results: Arthroscopically, meniscal lesions were detected in 55/186 segments (35 medial and 20 lateral meniscal lesions). Sensitivity, specificity, npv, ppv, and accuracy for combination of coronal and sagittal FS PDw TSE were 91.4%, 98.3%, 95%, 97%, and 93.5% for the medial meniscus, and 90%, 98.6%, 97.3%, 94.7%, and 96.8% for the lateral. The results were comparable to the combination of coronal T1w SE and sagittal PDw TSE for the medial (88.6%, 98.3%, 93.4%, 96.9%, 91.4%) and the lateral (90%, 95.9%, 97.2%, 85.7%, 92.5%) meniscus.

Conclusion: FS PDw TSE-MR sequences are an excellent alternative for the detection of meniscal lesions in comparison with diagnostic arthroscopy.  相似文献   

20.
Purpose: To assess prospectively the agreement of magnetic resonance (MR) pulmonary perfusion with single-photon emission computed tomography (SPECT) perfusion for perfusion defects down to the subsegmental level in patients with suspected pulmonary embolism (PE).

Material and Methods: In 41 patients with suspected PE, contrast-enhanced MR pulmonary perfusion (3D-FLASH, TR/TE 1.6/0.6 ms) was compared to SPECT perfusion on a per-examination basis as well as at the lobar, segmental, and subsegmental level.

Results: The MRI protocol was completed in all patients, and mean examination time was 3 min 56 s. MR perfusion showed a very high agreement with SPECT (kappa value per examination 0.98, and 0.98, 0.83, and 0.69 for lobar, segmental, and subsegmental perfusion defects, respectively). Of 15 patients with PE, MR perfusion detected 14 cases.

Conclusion: The very high agreement of MR perfusion with SPECT perfusion enables the detection of subtle findings in suspected PE.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号