首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 187 毫秒
1.
目的 探讨颈椎前路融合术中植骨块的高度对邻近节段关节突压力及活动度的影响,为临床上选择适宜的植骨高度提供依据。 方法 采用8例新鲜成人尸体颈椎标本,对完整状态,C5/6节段椎间隙减压术后(100%M、120%M、140%M、160%M)5组,于BOSE机加载下行三维运动,并测量颈C4/5,C6/7关节突压力值及C4/5,C6/7三维运动范围;最后将结果行多重比较分析。 结果 中立位状态下,关节突压力值各组无显著差异,P>0.05;后伸状态下,关节突压力值增加最大,各组有显著差异,P<0.05,但植骨高度中以120%M时关节突压力值增加最小,左右侧屈及左右旋转时,各组植骨高度之间差异均有显著意义,P<0.05,但植高度为120%M时,关节突压力值增加最小。在前屈后伸、左右侧屈下:120%M与完整状态相比,上下临近节段活动度差异无显著差异,P>0.05;与其他各组差异均有显著差异,P<0.05;2)在左右旋转时各组差异无显著差异,P>0.05。 结论 下颈椎单间隙减压植骨,撑开植骨理想高度为平均高度的120%。  相似文献   

2.
颈椎不同撑开高度时椎间隙的变化及其临床意义   总被引:3,自引:0,他引:3  
目的:探讨颈前路椎间隙减压植骨融合手术时椎间隙中间高度和椎间角度的变化规律。方法:10具成人颈椎标本,截取C2-7节段,按照Smith-Robinson手术方法进行C4/5间隙减压,用Caspar型颈椎撑开器加压2 mm和撑开2 mm、4 mm,在CR机上摄4种情况下颈椎左侧位片,Pacsout程序软件测量椎间隙中间高度和椎间角度,并统计分析。结果:撑开器压缩2 mm,C4/5椎间隙中间高度的变化值x(mm)和椎间角度的变化值y(°),分别为-1.3±0.5和-2.7±0.89;从原始状态撑开2 mm时,该变化值分别为1.5±0.84和4.6±2.0,从2 mm撑开至4 mm则分别为1.2±0.6和4.7±1.2;两者回归方程式y=2.24508x 1.482462,r=0.824(P<0.001)。结论:该方程式为解剖型颈椎间内植物的设计和应用等提供了方法和依据,应避免手术中过度撑开颈椎撑开器和在此状态下的植骨融合。  相似文献   

3.
目的 激光扫描三维重建后动态测量下颈椎椎间高度退变时相应节段椎间孔的变化,为临床诊治神经根型颈椎病提供新的思路和参考。 方法 选用6具新鲜成人尸体颈椎标本,以C5/6单节段脊柱功能单位(FSU)作为研究对象。椎间盘切除后将C5/6椎间高度置于基准高度状态,激光扫描仪扫描收集该状态下C5/6 FSU的空间关系信息,再对骨性单椎体进行全面扫描,在Geomagic Studio8.0软件中再现 C5/6基准状态,并模拟6种椎间高度退变模型,即C5椎向C6椎椎体面趋于平行移动基准高度的10%、 20%、30%、40%、50%和60%。多平面动态测量方法(MPDM)分别测量椎间孔容积、中间面积、内口以及外口面积。 结果 测量数据显示随着椎间高度持续的下降,椎间孔的容积和面积逐渐减小,当椎间高度丢失基准高度30%时,椎间孔中间面积首先开始与基准状态有显著性差异(P=0.003)。 结论 激光扫描三维重建原貌再现骨性表面,是获得精确测量数据的前提;动态测量的方法较为客观准确,是测量椎间孔的理想方法;测量发现在下颈椎骨性椎间孔随着椎间高度在下降而缩小,其中间面积首先发生显著缩小,提示此处容易发生狭窄而引起临床症状。  相似文献   

4.
目的 颈研究椎间孔横切面的面积与颈椎椎间隙狭窄程度的关系。方法  16件颈椎解剖标本 ,计算机辅助模拟 C4~ 5 ,C5~ 6和 C6~ 7椎间隙狭窄程度的关系。与正常的椎间孔面积相比 ,椎间隙狭窄 1mm椎间孔面积减少 2 0 %~ 30 % ,狭窄2 mm减少 30 %~ 40 % ,狭窄 3m m减少 35 %~ 45 %。结果 颈椎间孔横切面的面积与颈椎椎间隙狭窄程度有明显的统计学差别。结论 颈椎椎间隙塌陷导致的椎间孔内神经根受压不能被忽视 ,采用适当的手术方法保证椎间隙高度是有必要的 ,椎间孔的大小与椎间隙的高度有直接的关系。椎间隙垂直降低 3mm,常常导致严…  相似文献   

5.
目的 根据MRI测量正常国人颈椎椎间隙数据,研制符合国人解剖学特征的同种异体骨颈椎椎间融合骨垫。 方法 通过MRI测量100例C2,3至C6,7每个椎间隙的前缘、中点、后缘高度值及横径宽度值、矢状径长度值,其中男性有50人(20~55岁,平均年龄38.7岁),女性有50人(20~55岁,平均年龄36.1岁)。并根据该数据设计同种异体骨颈椎椎间融合骨垫。 结果 同节段颈椎椎间隙正中矢状面后缘高度<前缘高度<中间高度(P<0.05),椎间隙横径大于矢状径(P<0.05),同节段同部位的测量值,男性组大于女性组(P<0.05);同种异体骨颈椎椎间融合骨垫设计为前缘高度为6.0、7.0、8.0、9.0 mm 4个型号的楔状,其表面具有倒齿结构,中央有脱钙骨基质(DBM)置入孔,用于置入DBM粉末。 结论 依据MRI测量的颈椎椎间隙数据设计的同种异体骨颈椎融合骨垫符合国人解剖学要求。  相似文献   

6.
背景:研究表明,颈椎一体化前路钢板融合器比现行钢板和融合器具有更多理论上的优势。但是目前有关其生物力学方面的研究国内尚无文献报道。 目的:观察与评价颈椎前路一体化钢板椎间融合器内固定置入后的生物力学特征。 方法:采集6具成人尸体颈椎标本,分为5组进行测试,即正常组、椎间盘摘除组、颈椎前路一体化钢板椎间融合器固定组、CBK融合器固定组及CBK融合器+Secuplate钢板联合固定组,以C5~6椎间隙为观察对象,进行生物力学实验。 结果与结论:颈椎间盘摘除后,颈椎在各个方向运动加大,刚度及强度等生物力学数值减小,脊柱失稳。与椎间盘摘除组相比,颈椎前路一体化钢板椎间融合器固定后其强度增加24%,椎体应变减小31%,刚度增加14.3%,位移减小15%(P < 0.05),颈椎前路一体化钢板椎间融合器对颈椎的力学性能影响较小,说明它能较好地与颈椎的力学环境相匹配。CBK融合器固定后抗后伸及旋转作用相对较小,同椎间盘摘除组相比差异有显著性意义(P< 0.05)。CBK融合器+Secuplate钢板联合固定组载荷强度和应变过大,与椎间盘摘除组相比其强度增加27%,椎体应变减小38%,刚度增加17%,位移减小17% (P < 0.05),颈椎刚度增大且邻近椎节的运动有增大趋势,将引起力学性能的改变。提示颈椎前路一体化钢板椎间融合器结合了颈椎前路钢板和融合器生物力学方面的优点,能较好地与颈椎的力学环境相匹配。  相似文献   

7.
背景:前期实验设计和制作了钛合金金属橡胶角度人工颈椎间盘假体,于试图复制椎间盘在运动及应力分布这两方面的作用上进行了可行性研究。 目的:进一步观察金属橡胶角度人工颈椎间盘植入后山羊颈椎的稳定性变化。 方法:将9只山羊随机分为手术组(n=6)和正常对照组(n=3),手术组在C4/5节段植入金属橡胶角度人工颈椎间盘,正常对照组不予任何处理。分别于术前,术后即刻、4周、8周、12周行X射线正侧位、过伸过屈位,测量C4/5节段椎间隙高度、活动度及椎间角度,并进行手术节段硬组织切片包埋,苦味酸品红骨染色和扫描电镜观察。 结果与结论:手术组术后不同时间点C4/5节段椎间隙高度、脊柱活动度与术前及正常对照组比较差异无显著性意义;手术组术后即刻、4周、8周C4/5节段椎间角度高于术前(P < 0.05);手术组术后4,8,12周C4/5节段椎间角度与正常对照组比较差异无显著意义(P > 0.05)。术后4周时,手术组骨尚未与假体边缘接触;8周时骨与假体边缘间隙缩小,假体边缘有少量新生骨附着;12周时,假体表面有少量骨细胞存在,假体内部已有新生骨组织长入。表明金属橡胶角度人工椎间盘植入椎间隙后短期可维持椎间隙高度和活动度,与椎体结合牢固。中国组织工程研究杂志出版内容重点:生物材料;骨生物材料; 口腔生物材料; 纳米材料; 缓释材料; 材料相容性;组织工程全文链接:  相似文献   

8.
人工颈椎间盘置换术的解剖学参数测量   总被引:2,自引:0,他引:2  
目的:为人工颈椎间盘假体置换术提供解剖学参数。方法:志愿者43人,其中男性24人(22-43岁,平均年龄31.04岁),女性19例(23-39岁,平均年龄30.16岁)测量颈椎间盘215个。测量中立、屈曲、过伸位颈椎侧位X线片C2,3、C3,4、C4,5、C5,6、C6,7椎间隙前、后缘以及椎间隙中央的高度,数据进行统计和分析。结果:中立位、屈曲位、过伸位颈椎侧位片显示各颈椎间隙高度,不同性别、间隙、部位、姿态间存在显著差异(P=0.000),屈伸运动中,椎间盘前缘的运动幅度较中部和后缘大,屈曲时颈椎间盘前份和中央部均被显著压缩。结论:生理状态,屈伸运动中,椎间盘前部的运动占整个椎间盘运动幅度的绝大部分,椎间盘设计、制造和临床运用中,维持目标椎间隙前部的高度和活动度至关重要。  相似文献   

9.
目的:探讨人工颈椎间盘置换术后邻近下位关节突关节内压力的变化,为其在临床应用提供生物力学依据,方法:在11具保留C3至T1的新鲜成人颈椎标本上,采用自行设计的圆片状微阻电式传感器测量C5/6椎间盘完整、椎间盘摘除、人工椎间盘置换和椎间融合4个模型组C6/7关节突关节内的压力负荷.结果:人工椎间盘置换组C6/7关节突关节内的压力在轴向(16.98±3.74)N、左侧弯(26.87±5.78)N、右侧弯(12.91±3.50)N、前屈(20.88±5.77)N、后伸(20.63±5.30)N,与完整组接近,差异无统计学意义(P>0.05),高于椎间盘摘除组(P<0.05),低于椎间融合组(P<0.05).结论:人工颈椎间盘置换后邻近下位关节突关节内的压力接近正常,提示人工椎间盘置换符合颈椎正常生物力学要求.  相似文献   

10.
目的通过体外力学分析,研究颈脊柱姿势及椎间盘水化状态对颈脊柱运动单位整体压缩强度的影响。方法选用12具成人健康新鲜尸体颈段脊柱,解剖出C3-4、C5-6共24个运动单位(包括上下两个椎体和椎间盘)。施以压缩负荷,观察两种预负荷?状态(脱水和高度水化状态)和两种姿势(中立位和屈曲位)下颈段脊柱的极限压缩强度。通过解剖来明确颈椎的损伤。结果标本屈曲位时极限压缩强度比中立位时小(27%42%,P<0.001);在中立位外来负荷下,高度水化状态标本的极限压缩强度小于脱水状态的标本(29%,P<0.01)。结论晨起椎间盘高度水化状态下以及颈脊柱屈曲位时,受到外来负荷颈脊柱易损伤。  相似文献   

11.
目的 测量正常成人腰椎间盘相关参数,为设计符合国人腰椎结构特征的人工腰椎间盘和人工髓核提供参数值,同时提供正常人腰椎间隙高度数据,为临床诊断腰椎疾病提供依据。 方法 随机抽取自2010.1~2013.1间,腰背痛患者的MRI阴性图像资料300例(男136例,女164例)。分别测量L1/2~L5/S1 5个节段椎间隙的前高、中高、后高、角度以及L2/3~L5/S1 4个节段的椎间盘矢径、横径和髓核矢径、横径。 结果 各测量值年龄差异不显著(P>0.05)。性别差异显著,且测量值多为男性大于女性。节段差异显著(P<0.05),椎间盘前高和角度的测量值随着节段增加而递增,中高、后高、椎间盘矢径和横径、髓核矢径和横径的测量值除L5/S1节段外都随着节段的增高而递增。各节段椎间盘的矢径和横径,髓核的矢径和横径间存在线性关系。 结论 腰椎间隙高度测量对腰椎疾病的诊断具有参考价值;在设计人工腰椎间盘和人工髓核时应考虑性别和节段差异,并且应符合矢径和横径间的线性规律。  相似文献   

12.
On lateral roentgenograms of the cervical spine of 120 normal children between 3 and 14 years of age the ventral and dorsal height of all 5 intervertebral discs were measured and the "index of the intervertebral disc" was calculated. In addition, the "degree of lordosis" of the cervical spine was determined according to ISHIHARA (1964). Evaluation was in 3 age groups: 3 to 6, 7 to 10, 11 to 14 years; and the arithmetic mean and standard deviation were calculated for each group. All intervertebral discs are more or less "cuneiform" (ventrally higher than dorsally); they narrow from cranial to caudal. In children the degree of lordosis of the cervical spine shows a continuous decrease with advancing years. In all age groups girls show a lower degree of lordosis than boys. Statistically the differences of average values of the intervertebral-disc-index among the various shapes of the cervical spine in neutral position (straight, sublordotic, lordotic and hyperlordotic) are highly significant. By means of roentgenometric methods our examinations demonstrate that the lordotic curvature of the healthy cervical spine primarily depends on the cuneiform shape of intervertebral discs.  相似文献   

13.
目的 建立C4~5节段PrestigeTM-LP颈椎人工椎间盘植入后的三维有限元模型,进行手术节段的运动分析。 方法 采用对成年男性的新鲜尸体的颈椎标本进行CT三维扫描方法建立C4~5节段和PrestigeTM-LP人工间盘有限元,模拟完成C4~5人工椎间盘置换手术。测量生理加载下手术节段前屈/后伸、侧弯及轴向旋转运动角度。结果 有限元模型对颈椎的结构,包括椎体间韧带、颈椎关节突关节、钩椎关节等均进行了精确的重建,并较好地模拟手术操作进行PrestigeTM-LP人工间盘植入。运动加载后运动角度,前屈5.7°,后伸3.5°,侧弯5.0°,旋转11.3°,与文献报道结果较为接近。 结论 有限元模型具有精确度高,手术模拟真实的特点,可作为颈椎人工椎间盘生物力学研究的一种较好途径。PrestigeTM-LP颈椎人工椎间盘置换可较好地保留手术节段的运动功能。  相似文献   

14.
A cadaveric study was performed to investigate the relationship between disc degeneration and morphological changes in the intervertebral foramen of cervical spine, including the effect on the nerve root. Seven fresh frozen human cadavers were dissected from C1 to T1, preserving the ligaments, capsules, intervertebral disc and the neural structures. The specimens were scanned with MRI and then scanned through CT scan in the upright position. Direct mid-sagittal and 45 degree oblique images were obtained to measure the dimension of the intervertebral disc height, foraminal height, width, area and segmental angles. Disc degeneration was inversely correlated with disc height. There was a significant correlation between disc degeneration and foraminal width (p<0.005) and foraminal area (p< 0.05), but not with foraminal height. Disc height was correlated with foraminal width but not with height. The segmental angles were decreased more in advanced degenerated discs. There was a correlation between nerve root compression and decreased foraminal width and area (p<0.005). This information and critical dimensions of the intervertebral foramen for nerve root compression should help in the diagnosis of foraminal stenosis of the cervical spine in patients presenting with cervical spondylosis and radiculopathy.  相似文献   

15.
目的 提出一种联合颈椎前路钢板固定治疗屈曲牵张型颈椎损伤的新术式-颈椎轴向螺钉固定术,进行解剖学可行性研究。 方法 随机调取50例正常成年志愿者的颈椎侧位片。年龄22~48岁,平均28岁。通过JW-PACS图像系统,测量C2~6椎体高度;C2/3~C5/6椎间盘高度以及椎间盘矢径;并模拟轴向螺钉固定,即下位椎体前下缘至上位椎体后上缘的连线,测量轴向螺钉最大长度、头倾角以及植骨块深度等。采用一例防腐成人尸体标本,在C臂X线机透视下,模拟颈椎前路钢板固定并颈椎轴向螺钉固定术。 结果 轴向螺钉最大长度为(41.18±3.92)mm,轴向螺钉头倾角为(25.21±3.58)°。植骨块合适深度应小于椎间盘矢径(17.09±1.50)mm,且大于(11.69±1.63)mm,即略大于12 mm。尸体模拟手术表明,颈椎前路轴向螺钉固定在C2/3、C3/4、C4/5、C5/6均可以顺利完成, C6/7节段由于胸骨阻挡,无法进行轴向螺钉固定。 结论 颈椎前路钢板并轴向螺钉固定术治疗屈曲牵张性损伤具有操作可行性。  相似文献   

16.
目的 观察比较纳米羟基磷灰石/聚酰胺66颈椎融合器(n-HA/PA66 Cage)与聚醚醚酮颈椎融合器(PEEK Cage)在颈前椎间盘切除减压术后椎间隙植骨重建的初期疗效。 方法 回顾性分析2008年6月~2011年6月手术治疗资料完整的57例颈椎病患者,行颈前路椎间盘切除减压Cage植骨融合钛钉板系统内固定治疗,其中31例采用n-HA/PA66 cage, 26例采用PEEK cage 。术后随访包括影像学及临床疗效评价,影像学评价包括术前、术后正侧位片、动力位片观察植骨融合率、塌陷率、颈椎曲度及手术节段椎间隙高度情况;临床疗效采用Odom标准评定。 结果 n-HA/PA66组患者6月时获得97.7%植骨融合,PEEK组融合率100%,两组融合率无统计学差异(P>0.05);n-HA/PA66组术后颈椎丢失的角度为(2.06±1.77)°较PEEK组(2.39±1.56)°稍低,两组数据无统计学差异(P=0.384);n-HA/PA66组与 PEEK组术后平均椎间隙丢失高度无统计学意义(0.46±0.52 mm,0.41±0.18 mm,P=0.599),其中n-HA/PA66组出现1例患者1个节段塌陷,塌陷率2.3%,与PEEK组塌陷率(0%)比较无统计学差异(P=0.372);PEEK组获得81%临床优良率对比n-HA/PA66组77%的优良率无统计学差异(P=0.757)。 结论 颈前路椎间盘切除减压后,n-HA/PA66与PEEK cage椎间隙植骨融合并内固定治疗颈椎病的初期临床疗效与影像学结果均较好且相似。  相似文献   

17.
目的研究颈椎前路减压融合术中椎间融合器高度对颈椎生物力学影响,为融合器选择提供参考。方法建立正常颈椎C2~7节段有限元模型并验证,在C5~6节段分别植入高度为5、6、7、8 mm的融合器,施加1.5 N·m力矩使颈椎产生前屈、后伸、侧弯和轴向旋转运动,并探究融合器高度变化对颈椎活动度(range of motion,ROM)、小关节应力、椎间压强等的影响。结果融合器高度每增加1 mm,手术节段的角度值平均增加0.68°。植入融合器后C5~6 ROM范围小于0.44°。融合器高度差异对C4~5的ROM影响大于C6~7,对非融合节段ROM的影响小于7.3%。融合器高度差异对非手术节段ROM、小关节应力、相邻节段椎间压强的影响较小。关节囊韧带、融合器和钉板系统应力均随融合器高度增加而明显增加,6、7、8 mm融合器模型的关节囊韧带、融合器和钉板系统应力均远高于5 mm融合器模型。结论对于需要植入融合器的患者,建议植入物高度比原椎间隙高0~1 mm。  相似文献   

18.
背景:关于Modic改变在腰椎中分布及特点的相关性研究比较多,而在颈椎中的相关研究则较少。 目的:分析颈椎终板Modic改变的临床分布特点,并探讨其发生与颈椎退变的相关性。 方法:随机抽取因颈肩痛行颈椎MRI和常规X射线检查的患者共200例,年龄20~83岁。记录MRI颈椎Modic改变发生的节段,改变类型,改变的位置等,并分析其发生与性别、年龄、椎间盘退变节段及程度、椎间隙高度、颈椎曲度的相关性。 结果与结论:200例共计1 200个颈椎椎间盘中23例(11.5%),29个(2.4%)个椎间盘邻近终板发生Modic改变。Ⅰ型8例(4%),10个椎间盘(0.8%);Ⅱ型13例(6.5%),16个椎间盘(1.3%);Ⅲ型2例(1.0%),3个椎间盘(0.25%)。按照各个椎间盘节段发病数统计,C2/3节段O个,C3/4节段4个,C4/5节段6个,C5/6节段12个,C6/7节段7个,C7/T1节段0个,发病率分别为0%,0.33%,0.5%,1.0%,0.58%,0%。结果表明颈椎终板也存在Modic改变的现象,但发生率较腰椎低,Ⅱ型最多见,Ⅰ型次之,Ⅲ型最为少见,多发生于C5/6椎间盘,多位于邻近终板的后方。50岁以上为其好发年龄,其发生与年龄、椎间盘退变、椎间盘节段及颈椎曲度之间存在相关性。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号