首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 46 毫秒
1.

Purpose

Unreamed nails have revolutionised the treatment of tibial shaft fractures. Many authors, however, have reported increasing bone healing complications with these implants. Unfortunately, few studies have addressed the factors affecting bone healing after unreamed tibial nailing.

Methods

One-hundred and sixty tibial fractures in 158 patients (mean age 39.5 years) fixed using unreamed nails were reviewed. There were 78 AO type-A, 65 type-B and 17 type-C fractures (115 closed and 45 open fractures). Twelve patient, injury and surgery variables were analysed for their influence on fracture healing.

Results

Union occurred in all fractures after a mean time of 24.3 weeks. Additional surgery to achieve union, apart from dynamisation, was done in nine (6%) cases. The most important variables affecting healing were the mechanism of trauma (p = 0.005), fracture site gap (p = 0.01), degree of comminution (p = 0.0003), associated soft tissue injuries (p = 0.02) and the time to dynamisation (p = 0.0001).

Conclusions

High-energy trauma and fracture comminution have a negative impact on bone union and require close follow-up. It is essential to avoid distraction over three millimetres with unreamed nailing. Dynamisation is advised within ten weeks in axially stable fractures to encourage bone healing and avoid failure of the locking screws.  相似文献   

2.

Purpose

A study was conducted to compare minimum 15-year survivorship and outcome of the Genesis I and II implants for total knee arthroplasty (TKA).

Methods

We retrospectively reviewed 245 consecutive TKA implanted between January 1995 and October 1997. Genesis I was implanted in 156 knees and Genesis II in 89 knees.

Results

At 15–17 years, 75 patients (31 %) had died, 28 patients (11 %) were lost to follow-up and 11 TKA were revised (4.6 %), including ten Genesis I (6.4 %) and one Genesis II (1.1 %); 131 TKA (53 %) were available for follow-up. Cumulative survivorship was 92.4 % at 15.7 years. Survival in patients <69 years at surgery was lower (88.0 %) compared with patients ≥69 years (98.5 %; p = 0.023). In patients <69 years, Genesis I survival (84.3 %) was worse compared with Genesis II (97.1 %) (p = 0.018). Polyethylene (PE) Insert thickness ≤11 mm had significantly better survivorship (97.1 %) compared with PE >11 mm (56.7 %) (p < 0.0001)

Conclusions

At a minimum of 15 years, the overall (92.4 %) survivorship of Genesis TKA was good, with excellent (98.1 %) survivorship of the Genesis II design. Revision rates were higher with Genesis I in the younger age group and with insert thickness >11 mm, possibly due to longer shelf life of less frequently used sizes.  相似文献   

3.

Purpose

The aim of this study was to compare the results of a new technique for low, multidirectional locked nailing with closed reduction and minimally invasive plating in the treatment of distal tibial metadiaphyseal fractures.

Methods

Forty-six matched patients were divided according to age, gender, Injury Severity Score, and fracture pattern into group A (expert tibial nailing) and group B (minimally invasive plating). Then, the patients were followed up, and the clinical and radiographic results were retrospectively analysed.

Results

The mean followed-up was 24.7 ± 2.7 months in group A and 25.8 ± 2.8 months in group B. No patient had nonunion, shortening, hardware breakdown, or deep-seated infection. Patients in group A had a significantly shorter mean operating time, hospital stay, full weight-bearing time and union time (76 ± 16.6 vs. 90 ± 20.3 minutes, p = 0.000; 5.8 ± 2.1 vs. 8.9 ± 3.1 days, p = 0.000; 9.0 ± 1.4 vs. 11.1 ± 1.7 weeks, p = 0.000; and 21.3 ± 3.5 vs. 23.1 ± 3.6 weeks, p = 0.047, respectively). Three patients in group A and one patient in group B presented with malalignment (p = 0.608). The mean Olerud-Molander Ankle score was 89.0 ± 7.1 in group A and 87.6 ± 8.4 in group B (p = 0.478).

Conclusions

Distal tibia metadiaphyseal fractures may be treated successfully with low, multidirectional locked nails or plates. However, low, multidirectional locked nailing may represent a superior surgical option, since it offers advantages in terms of mean operating time, hospital stay, full weight-bearing time and union time.  相似文献   

4.

Purpose

The murine calvarial model has been widely employed for the in vivo study of particle-induced osteolysis, the most frequent cause of aseptic loosening of total joint replacements. Classically, this model uses an open surgical technique in which polyethylene (PE) particles are directly spread over the calvarium for the induction of osteolysis. We evaluated a minimally invasive modification of the calvarial model by using a direct subcutaneous injection of PE particles.

Methods

Polyethylene (PE) particles were injected subcutaneously over the calvaria of C57BL6J ten-week-old mice (“injection” group) or were implanted after surgical exposure of the calvaria (“open” group) (n = 5/group). For each group, five additional mice received no particles and served as controls. Particle-induced osteolysis was evaluated two weeks after the procedure using high-definition microCT imaging.

Results

Polyethylene particle injection over the calvaria resulted in a 40 % ± 1.8 % decrease in the bone volume fraction (BVF), compared to controls. Using the “open surgical technique”, the BVF decreased by 16 % ± 3.8 % as compared to controls (p < 0.0001).

Conclusions

Direct subcutaneous injection of PE particles over the murine calvaria produced more profound resorption of bone. Polyethylene particle implantation by injection is less invasive and reliably induces osteolysis to a greater degree than the open technique. This subcutaneous injection method will prove useful for repetitive injections of particles, and the assessment of potential local or systemic therapies.  相似文献   

5.

Purpose

This trial was designed to evaluate the impact of physical characteristics such as body mass index, body weight and height on distal stem migration of a cementless femoral component, as the influence of obesity on the outcome of THA is still debated in literature and conflicting results have been found.

Methods

In this retrospective cohort study, migration patterns for 102 implants were analysed using the Einzel-Bild-Roentgen-Analyse (EBRA-FCA, femoral component analysis). In all cases the Vision 2000 stem was implanted and combined with the Duraloc acetabular component (DePuy, Warsaw, Indiana).

Results

The mean follow-up was 93 months. EBRA-FCA evaluations revealed a mean subsidence of 1.38 mm after two years, 2.06 mm after five and 2.24 mm after seven years. Five stems loosened aseptically. Correlation between increased migration over the whole period and aseptic loosening was highly significant (p < 0.001). Surgical technique had a significant influence on migration and stem stability (p = 0.002) but physical patient characteristics such as body weight over 75 kg and height over 165 cm also significantly influenced stem subsidence towards progressive migration (p = 0.001, p < 0.001). However, a high BMI did not trigger progressive stem migration (p = 0.87). Being of the male gender raised the odds for increased migration (p = 0.03).

Conclusion

Physical characteristics such as body weight and height showed significant influence on migration patterns of this cementless femoral component. The operating surgeon should be aware that body weight above 75 kg and height over 165 cm may trigger increased stem migration and the surgeon should aim to fit these prostheses as tightly as possible. However this study demonstrates that a high BMI does not trigger progressive stem migration. Further investigations are needed to confirm our findings.  相似文献   

6.

Purpose

We compared types of complications leading to re-operations in open and closed distal tibia fractures treated by locking or nonlocking medial plates.

Methods

Ninety-three patients from 2002 to 2012 who underwent open reduction and internal fixation (ORIF) and medial plating for distal extra-articular or partial articular tibia fractures were identified. Charts were retrospectively reviewed to determine the incidence of re-operation based on the type of complication that developed. Fisher’s exact and chi-square tests were performed to analyze the incidence of complications based on injury and type of plate used.

Results

Thirty-three (35.5 %) patients required re-operations: 28.6 % (n = 16) with closed injuries had complications leading to re-operations compared with 45.9 % (n = 17) of patients with open injuries (p = 0.12). Patients with closed injuries were more likely to require re-operation due to hardware pain/prominence (p = 0.03), whereas patients with open injuries were more likely to require re-operation due to nonunion (p = 0.04). There were no significant differences in infection (p = 0.66) or malunion (p = 0.99) between groups. Locking plates showed higher costs but were not associated with decreased risk of re-operation.

Conclusions

There was a high re-operation rate associated with distal tibia medial plating, with significant differences in the reason for re-operation between open versus closed groups. Complication rates were not influenced by the use of locking plates. Results of this study suggest that methods be considered to reduce re-operation based on type of fracture, such as early bone grafting or the use of alternate implants for open fractures.  相似文献   

7.
Li H  Chen S  Wu Y  Jiang J  Ge Y  Gao K  Zhang P  Wu L 《International orthopaedics》2012,36(1):191-197

Purpose

The aim of the study was to investigate whether a bioactive glass (BG) coating on the polyethylene terephthalate (PET) artificial ligament could enhance graft osseointegration by promoting bone regeneration at the interface between PET graft and bone tunnel.

Methods

Thirty New Zealand white rabbits underwent artificial ligament graft transplantation in proximal tibial tunnels bilaterally. One limb was implanted with a 58S BG-coated PET graft, and the contralateral limb was implanted with a non-BG-coated PET graft as a control. The rabbits were randomly sacrificed at three, six and 12 weeks after surgery for biomechanical and histological examinations.

Results

The maximum load to failures of the BG-coated experimental group were significantly higher than those of the control group at 12 weeks (p = 0.0051). Histologically, at 12 weeks, the BG-coated PET graft induced great new bone formation between graft and host bone, and the average graft-bone interface width of the BG group became significantly lower than that of the control group. Furthermore, the BG coating on the ligament graft surface also stimulated greater expression of bone morphogenetic protein 2 (BMP-2) and vascular endothelial growth factor (VEGF) around the graft in vivo compared to the control group at three weeks (p < 0.05).

Conclusions

This study has shown that a BG coating on the PET artificial ligament surface has a positive effect in the induction of artificial ligament osseointegration within the bone tunnel.  相似文献   

8.

Purpose

Modern management of the elderly with a hip fracture is complex and costly. The aim of this study was to compare the treatment-related hospital length of stay (HLOS) before and after implementing a clinical pathway for patients undergoing hip fracture surgery.

Methods

This was a retrospective, before-and-after study. The first period ranged from June 21, 2008 to November 1, 2009 (N = 212), and the second was from January 7, 2010 to July 7, 2011 (N = 314). The electronic hospital system and patients records were reviewed for demographics, HLOS, mortality, complications and readmissions.

Results

In the first period 53 % had a femoral neck fracture, of which 57 % were treated with hemiarthroplasty. In the second period this was 46 % and 71 %. Pertrochanteric fractures were treated with a Gamma nail in 85 % in the first period, and in 92 % in the second period. The median HLOS decreased from nine to six days (p < 0.001). For the hemiarthroplasty group HLOS decreased from nine to seven days (p < 0.001); for internal fixation there was no significant difference (five versus six days, p = 0.557) and after Gamma nailing it decreased from ten to six days (p < 0.001). For mortality no statistically significant difference was found (6 % versus 5 %, p = 0.698). Complications decreased for the Gamma nail group (44 % versus 31 %, p = 0.049). Readmissions for the total group were not different (16 % versus 17 %, p = 0.720).

Conclusions

Implementing a clinical pathway for hip fractures is a safe way to reduce the HLOS and it improves the quality of care.  相似文献   

9.

Purpose

The treatment of choice for a displaced femoral neck fracture in the most elderly patients is a cemented hemiarthroplasty (HA). The optimal design, unipolar or bipolar head, remains unclear. The possible advantages of a bipolar HA are a better range of motion and less acetabular wear. The aim of this study was to evaluate hip function, health related quality of life (HRQoL), surgical outcome and acetabular erosion in a medium-term follow-up.

Methods

One hundred and twenty patients aged 80 or more with a displaced fracture of the femoral neck (Garden III and IV) were randomised to treatment with a cemented Exeter HA using a unipolar or a bipolar head. All patients were able to walk independently, with or without aids, before surgery. Follow-ups were performed at four, 12, 24 and 48 months postoperatively. Assessments included HRQoL (EQ-5D index score), hip function (Harris hip score [HHS]) and radiological acetabular erosion.

Results

The mean EQ-5D index score was generally higher among the patients with bipolar hemiarthroplasties at the follow-ups with a significant difference at 48 months: unipolar HAs 0.59 and bipolar HAs 0.70 (p = 0.04). There was an increased rate of acetabular erosion among the patients with unipolar hemiarthroplasties at the early follow-ups with a significant difference at 12 months (unipolar HAs 20 % and bipolar HAs 5 %, p = 0.03). At the later follow-ups the incidence of acetabular erosion accelerated in the bipolar group, and there were no significant differences between the groups at the 24- and 48-month follow-ups. There was no difference in HHS or reoperation rate between the groups at any of the follow-ups.

Conclusion

The bipolar HAs seem to result in better HRQoL beyond the first two years after surgery compared to unipolar HAs. Bipolar HAs displayed a later onset of acetabular erosion compared to unipolar HAs.  相似文献   

10.

Purpose

Press-fit cementless radial head implant longevity relies on adequate bone ingrowth. Failed implant osseointegration remains a clinical concern and has been shown to lead to prosthetic failure. The purpose of this study was to test the hypothesis that implants with sufficient initial press-fit stability would be less likely to fail due to implant pull-out, as demonstrated by an increasing amount of energy required to remove the prosthesis from the canal.

Methods

Ten cadaveric radii were implanted with five sizes (6–10 mm in 1-mm increments) of grit-blasted, cementless radial head stems. A customised slap hammer was used to measure the energy required to remove each stem. Stem-bone micromotion was also measured.

Results

The suboptimally sized stem (Max − 1) (i.e. 1 mm undersized) required less energy (0.5 ± 0 J) to pull out than the optimally sized stem (Max) (1.7 ± 0.3 J) (p = 0.008). The optimally sized stem demonstrated greater initial stability (45 ± 7 μm) than the suboptimally sized stem (79 ± 12 μm) (p = 0.004).

Conclusions

This investigation demonstrates the importance of obtaining adequate press-fit stability for the prevention of radial head stem pull-out failure. These data add to the relatively scant knowledge in the literature regarding radial head biomechanics. The energy required to remove a prosthetic radial head ingrowth stem decreases in conjunction with diameter. The use of an inadequately sized stem increases the stem’s micromotion as well as the risk of prosthetic loosening due to pull-out.  相似文献   

11.

Purpose

Total hip arthroplasty (THA) as primary treatment for displaced femoral neck fractures is controversial as THA is associated with higher rates of dislocation but lower rates of re-operation compared to hemiarthroplasty (HA). A dual mobility cup (DMC) design is associated with lower dislocation and re-operation rates in elective surgery. Is this also the case when used to treat displaced femoral neck fractures? The aim of this study is to compare rates of dislocation and re-operation of any kind following treatment for displaced femoral neck fractures with either bipolar HA or THA with DMC.

Methods

Two consecutive groups of patients treated for displaced femoral neck fractures at the Regional Hospital in Viborg in Denmark were included. In 2007–2008 171 patients (mean age 84.1 years) were treated with bipolar HA. In 2009–2010 175 patients (mean age 75.2 years) were treated with THA with DMC. Data regarding rates of dislocation and re-operation were obtained by retrospective review of medical records.

Results

We found a statistically significant difference regarding rates of dislocation and re-operation of any kind in favour of THA with DMC. Dislocation occurred in 25/171 patients [95 % confidence interval (CI) 9.3–19.9 %] treated with bipolar HA and 8/175 patients (95 % CI 1.5–7.7 %) treated with THA with DMC (p = 0.002). Re-operations were required in 32/171 patients (95 % CI 12.9–24.6 %) treated with bipolar HA and 16/175 patients (95 % CI 4.8–13.4 %) treated with THA with DMC (p = 0.01).

Conclusions

Our findings indicate that THA with DMC is superior to bipolar HA following treatment for displaced femoral neck fractures in regard to rates of dislocation and re-operation.  相似文献   

12.

Purpose

Tranexamic acid (TXA) reduces blood loss in patients undergoing total knee arthroplasty (TKA). However, few studies have reported the optimum timing and dosage for administration of TXA. The purpose of this study was to evaluate the effect of repeat-dose TXA on blood loss during TKA and the necessity of autologous blood donation or postoperative autotransfusion.

Methods

We enrolled 78 patients with primary osteoarthritis undergoing cemented TKAs. Consecutive patients were divided into three groups, as follows: control group (n = 31), single-TXA group (n = 21) in whom TXA (1,000 mg) was intravenously administered 10 min before deflation of the tourniquet, and twice-TXA group (n = 26) in whom TXA (1,000 mg) was intravenously administered 10 min before deflation of the tourniquet and 3 h after the operation. We measured the volume of drained blood after the operation. Haemoglobin (Hb) levels were measured at days 1, 4 and 7 postoperation. Venous thromboembolic events (VTE) were screened using compression ultrasonography at enrollment and 1 and 7 days after operation.

Results

The mean volume of drained blood after the operation was lower in the twice-TXA group than in the single-TXA (p < 0.001) and control (p < 0.0001) groups. No significant differences were observed in the incidence of VTE between these groups.

Conclusion

Administration of TXA twice reduced postoperative blood loss after TKA, and TXA was not associated with the risk of deep-vein thrombosis (DVT) or pulmonary embolism (PE). Further, administration of TXA twice may eliminate the need for blood transfusion during TKA.  相似文献   

13.

Purpose

Component orientations and positions in total hip arthroplasty (THA) are important parameters in restoring hip function. However, measurements using plain radiographs and 2D computed tomography (CT) slices are affected by patient position during imaging. This study used 3D CT to determine whether contemporary THA restores native hip geometry.

Methods

Fourteen patients with unilateral THA underwent CT scan for 3D hip reconstruction. Hip models of the nonoperated side were mirrored with the implanted side to quantify the differences in hip geometry between sides.

Results

The study demonstrated that combined hip anteversion (sum of acetabular and femoral anteversion) and vertical hip offset significantly increased by 25.3° ± 29.3° (range, −25.7° to 55.9°, p = 0.003) and 4.1 ± 4.7 mm (range, −7.1 to 9.8 mm, p = 0.009) in THAs.

Conclusions

These data suggest that hip anatomy is not fully restored following THA compared with the contralateral native hip.  相似文献   

14.

Purpose

We evaluated radiographic fusion at follow-up and complication rates in patients who had either iliac crest (ICBG) or femoral reamer–irrigator–aspirator (RIA) bone graft for tibiotalar fusion.

Methods

We retrospectively reviewed charts and radiographs of all patients who had a tibiotalar fusion from August 2007 to February 2011. Records were analysed for patient demographics, complications, and clinical symptoms. Radiographs were reviewed in sequential order by two fellowship-trained foot and ankle surgeons and one orthopaedic surgeon who specialises in foot and ankle surgery to determine radiographic fusion at routine follow-up. Patients were contacted to determine current visual analog scores (VAS) at their graft site.

Results

Mean patient age was 49.4 ± 12.1 years in the RIA group and 49.3 ± 15.4 years in the ICBG group (p = .97). Pre-operative characteristics showed no significant differences between groups. The ICBG group had significantly more nonunions than the RIA group (six vs. one, p = 0.04). Two patients in the ICBG had chronic pain at their graft site based on their VAS score; there were none in the RIA group. Radiographic fusion at follow-up was similar between groups, with no significant difference (12.48 ± 3.85 weeks vs.12.21 ± 3.19 weeks, p = .80).

Conclusions

There was a significantly higher nonunion rate in the ICBG group, but both groups had a solid radiographic bony fusion at similar follow-up time points. Our results suggest RIA bone graft is a viable alternative to ICBG for tibiotalar fusion.  相似文献   

15.

Purpose

The purpose of this study was to determine whether platelet-rich plasma (PRP) might prevent blood loss and postoperative pain and expedite wound healing following total knee arthroplasty (TKA).

Methods

Forty consecutive patients with knee arthritis who were matched for age, sex and body mass index (BMI) were randomly allocated to either receive or not receive PRP application over the wound, including capsule, medial and lateral recesses, during TKA. Postoperative haemoglobin, blood loss, blood transfusion, visual analogue scale (VAS) score, wound score, Knee Society Score (KSS) and Western Ontario and McMaster Osteoarthritis Index (WOMAC) score were recorded and evaluated.

Results

The platelet-rich plasma and control groups comprised 17 and 23 patients, respectively. The PRP group recorded significantly less reduction in haemoglobin and need for blood transfusion (p = 0.00 and p = 0.001, respectively), experienced less pain (p = 0.00) and required fewer narcotics than the control (p = 0.00). There was significant difference in range of motion (ROM) at three months (p = 0.01), no significant difference in wound scores (p = 0.311) and significant difference in KSS and WOMAC scores at 12 weeks (p = 0.00, 0.00). However no significant difference was found at six months.

Conclusions

PRP has significant effect in preventing blood loss, postoperative pain and need for narcotics after TKA and has a positive effect on short-term clinical outcome.  相似文献   

16.

Purpose

The aim of this study was to assess the stability of the glycosaminoglycan (GAG) content in the long term after matrix-associated autologous chondrocyte transplantation (MACT) with Hyalograft C in the knee over a follow-up period of one year.

Methods

In this cross-sectional evaluation, 11 patients after MACT of the knee consented to delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC) measurements. The mean post-operative interval before the first MR examination was 40.6 ± 22.0 months, and the second MR examination was carried out after another 12 months. The Lysholm score was assessed for clinical evaluation. Quantitative T1 measurements after intravenous negatively charged MR contrast agent administration were performed. Global post-contrast T1 of the reference cartilage and the repair tissue and a relative post-contrast T1 value were calculated.

Results

The Lysholm score improved significantly from 59.8 ± 12.9 at baseline to 86.1 ± 15.7 at the second visit (p < 0.01). The mean global T1 of the repair tissue (1st visit 581.3 ± 126.4 ms; 2nd visit 684.1 ± 169.9 ms; p = 0.104) and the mean relative T1 value showed stable results over one year (1st visit 0.81 ± 0.28; 2nd visit 0.76 ± 0.32; p = 0.4).

Conclusions

The study demonstrated stable glycosaminoglycan content of the repair tissue after MACT at midterm.  相似文献   

17.

Purpose

Revision total knee arthroplasty (rTKA) is a complex procedure. Depending on the degree of ligament and bone damage, either primary or revision implants are used. The purpose of this study was to compare survival rates of primary implants with revision implants when used during rTKA.

Methods

A retrospective comparative study was conducted between 1998 and 2009 during which 69 rTKAs were performed on 65 patients. Most common indications for revision were infection (30 %), aseptic loosening (25 %) and wear/osteolysis (25 %). During rTKA, a primary implant was used in nine knees and a revision implant in 60.

Results

Survival of primary implants was 100 % at one year, 73 % [95 % confidence interval (CI) 41–100] at two years and 44 % (95 % CI 7–81) at five years. Survival of revision implants was 95 % (95 % CI 89–100) at one year, 92 % (95 % CI 84–99) at two years and 92 % (95 % CI 84–99) at five years. Primary implants had a significantly worse survival rate than revision implants when implanted during rTKA [P = 0.039 (hazard ratio = 4.56, 95 % CI 1.08–19.27)].

Conclusions

Based on these results, it has to be considered whether primary implants are even an option during rTKA.  相似文献   

18.

Purpose

Nitric oxide (NO) synthesised by endothelial NO synthase (eNOS) is a potent regulator of internal haemodynamics. A polymorphism in intron 4 of the eNOS is associated with different vascular disorders. We investigated the potential involvement of this polymorphism in idiopathic and secondary osteonecrosis of the femoral head (ONFH) in Polish patients.

Methods

We performed a study involving 68 patients with ONFH (45 idiopathic and 23 secondary) and 100 healthy controls. All subjects were genotyped for the eNOS4 polymorphism by the polymerase chain reaction followed by agarose gel electrophoresis.

Results

The analysis revealed that the frequencies of eNOS4 genotypes were significantly different in ONFH patients (both idiopathic and secondary) than in controls. The frequencies of the 4a allele were significantly higher in the total group of patients versus controls [22.79 vs 9 %, p = 0.00039, odds ratio (OR) 2.98]. In subgroup analysis the 4a allele increased significantly in both idiopathic (20 vs 9 %, p = 0.0074, OR = 2.52) and secondary (28.26 vs 9 %, p = 0.00047, OR = 3.98) ONFH patients compared to control subjects. The frequency of the 4a/b genotype in the total group of patients (36.76 vs 16 %, p = 0.0011, OR = 3.24) as well as patients with idiopathic (35.56 vs 16 %, p = 0.0069, OR = 2.96) and secondary (39.13 vs 16 %, p = 0.0073, OR = 3.89) ONFH was higher than in the control group.

Conclusions

There was a significantly higher frequency of eNOS 4a allele carriers among the total group of patients as well as in idiopathic and secondary ONFH. This suggests that the eNOS gene polymorphism may be associated with increased risk of ONFH.  相似文献   

19.

Purpose

The purpose of this study was to assess the MRI features of the all-inside repaired meniscus in the long-term.

Methods

Among 27 consecutive all-inside arthroscopic meniscal repairs, 23 patients aged 25 ± 5 years at the time of surgery were reviewed at a median follow-up of 10 ± 1 years. Retrospective clinical examinations and imaging assessments using a 1.5-T MRI after all-inside arthroscopic meniscal repair were conducted.

Results

At follow-up, Lysholm and IKDC averaged 89 ± 11 and 95 ± 8, respectively. MRI examinations revealed no meniscal signal alteration in three patients (13 %), a vertical signal located in the previously torn area in seven (30 %), a horizontal grade 3 in nine (39 %), and a complex tear (grade 4) in four (17.5 %). There were no differences between medial and lateral menisci (p = 0.15), stable and stabilised knees (p = 0.56).

Conclusions

Several abnormal vertical and/or horizontal hypersignals are still present on MRI examination ten years after arthroscopic all-inside meniscal repair. The appearance of early signs of osteoarthritis is rare, suggesting a chondroprotective effect of the repaired meniscus.  相似文献   

20.

Purpose

This prospective randomized pilot study reports our institutional experience and early results using Sonoma Wrx (Sonoma Orthopedic Products, Santa Rosa, CA) in the treatment of extra-articular and simple intra-articular distal radius fractures.

Material and methods

A total of 64 patients, were enrolled in the study. They were considered eligible if they had; unstable extra-articular distal radius fractures and simple intra-articular distal radius fractures suitable for closed reduction (AO types; A2.2, A2.3, A3.1 C2.1, C2.2). Patients in group I received intramedullary fixation using the Sonoma Wrx® device and patients in group II received standard volar locking plate fixation. Radiographic criteria of acceptable healing were used for evaluation.

Results

Two groups were similar in terms of baseline characteristics. Mean time of operation was significantly shorter in Group 1 vs. in group 2 (36.81 ± 7.11 vs. 48.97 ± 5.9 minutes, p = 0.001). Time to healing of the fracture was not different between two groups (5.45 ± 1.09 vs. 5.70 ± 1.04 weeks for Group 1 vs. 2, respectively p = 0.36). Overall complications occurred in 9 patients in group 1 and in 15 patients in group 2 (p = 0.17). Follow-up was completed in all patients with a median time of 12 months and 13 months in group 1 and 2, respectively. On radiographic evaluation radial inclination, radial height and volar tilt were not significantly different between group 1 and 2, respectively. There were no significant differences between two groups in regard to wrist rotational degrees measured in last follow-up visit.

Conclusion

Sonoma Wrx Device is reliable and effective in terms of achieving satisfactory outcomes in treatment of distal radius fractures. It may be reasonable to use this device to prevent complications that are related to extensive soft tissue dissection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号