共查询到20条相似文献,搜索用时 15 毫秒
1.
Iver Lausen Ren Jensen Peer Wille-Jrgensen Lars N. Jrgensen Morten S. Rasmussen Karen M. Lyng Mette Andersen Hans O. Raaschou 《European journal of radiology》1995,20(3):200-204
Objective: To evaluate colour Doppler flow imaging ultrasonography (CDFI), compared with venography, as a screening method for postoperative deep venous thrombosis (DVT) in a clinical trial on thromboprophylaxis. Methods: Patients undergoing major abdominal or thoracic surgery were prospectively screened for DVT by CDFI. Patients were examined preoperatively, and on postoperative days 1, 3, 7, 14, 21, and 28. When the CDFI was positive venography was performed. Bilateral venography was performed on day 28 in all patients. The study group comprised 82 patients who underwent CDFI and venography on the same day: four because of suspected DVT (positive CDFI), and 78 on day 28 according to protocol. Results: DVT was detected by venography in seven patients, in three of whom CDFI was positive. CDFI was falsely positive in one case. There were two popliteal and five calf DVTs, of which CDFI detected one and two, respectively. The sensitivity of CDFI was 43%, the specificity 99%. The PVpos for CDFI was 75%, and the PVneg 96%. Conclusion: Due to low sensitivity, CDFI cannot stand alone as a screening method for asymptomatic postoperative DVT. 相似文献
2.
3.
Fewer than 20 cases of adventitial cystic disease of the vein have been reported in the worldwide literature. This small number of reported cases may be due not only to the disease''s low incidence, but also to the difficulty in making the proper diagnosis. Many techniques have been used to investigate this disease, but venography has been the traditional diagnostic tool. In this report we present a case of adventitial cystic disease that was well demonstrated by CT venography. 相似文献
4.
Raza SA Chughtai AR Wahba M Cowling MG Taube D Wright AR 《Cardiovascular and interventional radiology》2004,27(1):9-15
Purpose: To assess the role of
multislice computed tomography angiography (MCTA) in the evaluation of
renal artery stents, using intra-arterial digital subtraction
angiography (DSA) as the gold standard.
Methods: Twenty
consecutive patients (15 men, 5 women) with 23 renal artery stents
prospectively underwent both MCTA and DSA. Axial images, multiplanar
reconstructions and maximum intensity projection images were used for
diagnosis. The MCTA and DSA images were each interpreted without
reference to the result of the other investigation.
Results:
The three cases of restenosis on DSA were detected correctly by MCTA;
in 19 cases where MCTA showed a fully patent stent, the DSA was also
negative. Sensitivity and negative predictive value (NPV) of MCTA were
therefore 100%. In four cases, MCTA showed apparently minimal disease
which was not shown on DSA. These cases are taken as false positive
giving a specificity of 80% and a positive predictive value of
43%.
Conclusion: The high sensitivity and NPV suggest
MCTA may be useful as a noninvasive screen for renal artery stent
restenosis. MCTA detected mild disease in a few patients which was not
confirmed on angiography. 相似文献
5.
6.
Sun Ho Kim 《Korean journal of radiology》2002,3(1):45-48
Objective
To assess the usefulness of pulsatile flow detection (PFD), a newly developed function of color Doppler US, in measuring resistive index (RI) in renal Doppler US and to compare it with conventional color Doppler (CCD).Materials and Methods
Fifty-six kidneys in 31 patients were randomly selected and divided into two groups. In group A, RI was measured first with the aid of CCD, and then with PFD. In group B, data were obtained in the reverse order. The time required for each RI measurement was recorded in seconds. The quality of the Doppler spectral waveform was subjectively graded as 0, 1, or 2 and examination time and waveform quality were compared between PFD and CCD.Results
The time required to measure RI with PFD (PFD time) was less than with CCD (CCD time) (mean 42.7 secs vs. mean 70.3 secs; p = 0.031). There was no significant difference in PFD time between group A and B, but CCD time was shorter in group B (70.3 secs vs. 24.6 secs; p = 0.0004). Spectral waveform quality was not significantly different between PFD and CCD.Conclusion
The time required to measure RI in kidneys can be shortened with the aid of the PFD function in color Doppler US without affecting the quality of the examination. 相似文献7.
RATIONALE AND OBJECTIVES: The authors performed this study to evaluate a new method (medial axis reformation [MAR]) for visualizing three-dimensional vascular data at electron-beam computed tomographic (CT) angiography. MATERIALS AND METHODS: MAR was performed automatically with a personal computer-based workstation. After the region of interest was edited, voxels were divided into groups according to their path lengths. Centroids of groups were connected to form the medial axis. Then, the medial axis was refined with multiscale medial response. Bifurcations were also detected and refined. Finally, curved sections were generated through the branches and laid out onto a single image by using a splitting method. The authors performed MAR during electron-beam CT angiography of coronary arteries, common carotid arteries, and iliac arteries. RESULTS: MAR displayed curved sections of branched vessels on one image, cut through the axis of vessels to show the vessel diameter objectively, and allowed the viewing direction to be altered arbitrarily. CONCLUSION: Results of preliminary applications demonstrate that MAR is a valuable new visualization method for CT angiography. 相似文献
8.
Brader P Schoellnast H Deutschmann HA Thimary F Schaffler G Reittner P 《European journal of radiology》2008,66(1):31-36
PURPOSE: The purpose of this study was to evaluate the ability of rotated paddlewheel reformations for the detection of central and peripheral pulmonary embolism (PE) compared to standard axial multi detector CT (MDCT) images. MATERIAL AND METHODS: CT scans of 35 patients with PE were reviewed by three independent readers for the detection of pulmonary emboli using standard axial CT scans and reformatted paddlewheel technique. All images were evaluated in random order. MDCT examinations were performed with a collimation of 1.25 mm, a pitch of six and a reconstruction interval of 0.8mm. For each patient MIP were reformatted by using a paddlewheel arrangement with 5mm slab thickness and 5 degrees rotation. Standard of reference for PE was a consensus reading of the axial images by all three readers. RESULTS: The overall sensitivity for the axial images for the three readers ranged between 91% and 96%; for paddlewheel reformations from 78% to 83%; the specificity for both methods was 98-99%. Inter- and intraobserver agreement was also higher for axial images than for paddlewheel reformations. CONCLUSION: Comparing standard axial MDCT scans and reformatted paddlewheel images no significant difference for the detection of central PE was found, whereas for the detection of peripheral emboli standard axial images showed a significant higher percentage of detecting PE than paddlewheel reformations. 相似文献
9.
RATIONALE AND OBJECTIVES: The authors' purpose was to identify the optimal strategy for using compression ultrasonography (US) in patients suspected of having deep venous thrombosis (DVT). MATERIALS AND METHODS: The authors developed a decision-analytic model representing the natural history of DVT and the benefits and risks of anticoagulation therapy. They evaluated six initial imaging strategies: (a) unilateral examination of the common femoral and popliteal veins; (b) unilateral examination of the common femoral, popliteal, and femoral veins; (c) bilateral examination of the common femoral and popliteal veins; (d) bilateral examination of the common femoral, popliteal, and femoral veins; (e) complete unilateral examination of the symptomatic leg (including calf veins); and (f) complete bilateral examination of both legs. RESULTS: For 65-year-old men with unilateral symptoms of DVT, the most effective strategy was bilateral examination of the common femoral and popliteal veins with anticoagulation therapy in patients with proximal DVT and follow-up bilateral examination of the common femoral and popliteal veins in patients without an initial diagnosis of DVT with an incremental cost-effectiveness ratio of $39,000 per quality-adjusted life year gained. CONCLUSION: These results suggest that bilateral examination limited to the common femoral and popliteal veins, with follow-up bilateral examination limited to the common femoral and popliteal veins, was as cost-effective as other well-accepted medical interventions. The results were sensitive to the distribution of clot, diagnostic accuracy of compression US, and probability of bleeding with long-term morbidity. 相似文献
10.
Fabio Pinto M.D. Riccardo Lencioni M.D. Andrea Falleni M.D. Alessandra Tozzini M.D. Mariano Scaglione M.D. Raffaello Stringari M.D. Emanuele Neri M.D. 《Emergency radiology》1998,5(2):92-96
The purpose of our study was to compare power Doppler sonography (US) and conventional color Doppler US in the diagnosis of
acute appendicitis by revealing local signs of hyperemia. One hundred consecutive patients (46 males and 54 females, ages
7–61 years; mean, 24.7 years) with clinically suspected acute appendicitis were prospectively examined with power Doppler
US and conventional color Doppler US. Of 38 patients who subsequently underwent surgery, appendicitis was proven in 34. The
remaining 62 patients who were not submitted to surgery had no clinical evidence of appendicitis over a 2- to 6-month follow-up.
At gray-scale US, the appendix was visualized in 30 (88.2%) of the 34 cases with pathologically proven acute appendicitis.
Power Doppler US depicted a moderate to marked hypervascularity of the appendiceal wall and surrounding mesoappendix in 28
(93.3%) of these 30 patients. At conventional color Doppler US, flow signal within the appendiceal wall and surrounding mesoappendix
was shown in only 21 (70%) of 30 cases (P<0.05). No false-positive diagnosis was made at either power or color Doppler US among the 62 patients without appendicitis.
Power Doppler US is more sensitive than conventional color Doppler imaging for revealing signs of local hyperemia in acute
appendicitis. 相似文献
11.
Shigeru Suzuki Shigeru Furui Sadatoshi Kuwahara Dhruv Mehta Tatsuro Kaminaga Akiyoshi Miyazawa Yasunari Ueno Kumiko Konno 《Korean journal of radiology》2009,10(3):217-226
Objective
We wanted to evaluate the performance of prospective electrocardiogram (ECG)-gated axial scans for assessing coronary stents as compared with retrospective ECG-gated helical scans.Materials and Methods
As for a vascular model of the coronary artery, a tube of approximately 2.5-mm inner diameter was adopted and as for stents, three (Bx-Velocity, Express2, and Micro Driver) different kinds of stents were inserted into the tube. Both patent and stenotic models of coronary artery were made by instillating different attenuation (396 vs. 79 Hounsfield unit [HU]) of contrast medium within the tube in tube model. The models were scanned with two types of scan methods with a simulated ECG of 60 beats per minute and using display field of views (FOVs) of 9 and 18 cm. We evaluated the in-stent stenosis visually, and we measured the attenuation values and the diameter of the patent stent lumen.Results
The visualization of the stent lumen of the vascular models was improved with using the prospective ECG-gated axial scans and a 9-cm FOV. The inner diameters of the vascular models were underestimated with mean measurement errors of -1.10 to -1.36 mm. The measurement errors were smaller with using the prospective ECG-gated axial scans (Bx-Velocity and Express2, p < 0.0001; Micro Driver, p = 0.0004) and a 9-cm FOV (all stents: p < 0.0001), as compared with the other conditions, respectively. The luminal attenuation value was overestimated in each condition. For the luminal attenuation measurement, the use of prospective ECG-gated axial scans provided less measurement error compared with the retrospective ECG-gated helical scans (all stents: p < 0.0001), and the use of a 9-cm FOV tended to decrease the measurement error.Conclusion
The visualization of coronary stents is improved by the use of prospective ECG-gated axial scans and using a small FOV with reduced blooming artifacts and increased spatial resolution. 相似文献12.
Hyo-Cheol Kim Jin Wook Chung Jae Hyung Park Yong Hu Yin Seong Ho Park Chang Jin Yoon Young Ho Choi 《Korean journal of radiology》2003,4(3):146-152
Objective
To evaluate the role of CT venography in the diagnosis and treatment of benign thoracic central venous obstruction.Materials and Methods
Eighteen patients who had undergone both CT venography and digital subtraction venography were prospectively enrolled in this study. The following features were analyzed by two observers: the cause, degree, and extent of venous obstruction; associated thrombosis; and implications for the planning of treatment. CT venography and digital subtraction venography were compared in defined venous segments, and the degree of obstruction, and correlation was expressed using Spearman''s rank correlation coefficient.Results
In all patients, CT venography depicted the causes of obstruction, including extrinsic compression of the left brachiocephalic vein, and mediastinal inflammatory pseudotumor. Interobserver agreement regarding classification of the degree of obstruction was judged as good for CT venography (κ=0.864), and in evaluating this, there was significant correlation between CT venography and digital subtraction venography (reader 1: Rs = 0.58, p < 0.01; reader 2: Rs = 0.56, p < 0.01). In evaluating the status of central veins proximal to long segmental obstruction, and associated thrombosis, CT venography was superior to digital subtraction venography. In half of all patients, the findings of CT venography led to changes in the treatment plan.Conclusion
The findings of CT venography correlated closely with those of digital subtraction venography, and the former accurately depicted the degree and extent of benign venous obstruction. 相似文献13.
Langenberger H Friedrich K Plank C Matzek W Wolf F Storto ML Schaefer-Prokop C Herold C 《European journal of radiology》2009,70(3):579-588
Objectives
To compare iomeprol 400 and iodixanol 320 in pulmonary artery MDCTA in subjects with suspected pulmonary embolism.Methods
Eighty randomized subjects received equi-iodine intravenous doses (48 g) of iomeprol 400 (n = 40) or iodixanol 320 (n = 40), via power injector at 4 mL/s. Four-row (35 subjects) and 64-row (45 subjects) scanners were used. Lumen attenuation was determined on-site and by two off-site blinded readers in the main, lobar, segmental and subsegmental pulmonary arteries. Statistical comparison between groups was performed for demographics and lumen attenuation.Results
There were no between-group differences (p > 0.05) in demographics. Pulmonary artery attenuation was significantly (p ≤ 0.03) higher with iomeprol 400 for all readers. Attenuation quality was excellent in more patients after iomeprol 400 than after iodixanol-320 (80% vs. 62.5%; 82.5% vs. 77.5%; off-site readers 1 and 2, respectively). No safety concerns were noted.Conclusion
The greater iodine delivery rate achievable with iomeprol 400 compared to iodixanol-320 at equi-iodine dose and injection rate permits consistently greater attenuation at all levels of the pulmonary arterial tree. 相似文献14.
Kyoung Won Kim Tae Kyoung Kim Joon Koo Han Ah Young Kim Hyun Ju Lee Seong Ho Park Young Hoon Kim Byung Ihn Choi 《Korean journal of radiology》2000,1(4):191-197
Because US plays a key role in the initial evaluation of hepatic hemangiomas, knowledge of the entire spectrum of US appearances of these tumors is important. Most hemangiomas have a distinctive US appearance, and even with those with atypical appearances on conventional gray-scale US, specific diagnoses can be made using pulse-inversion harmonic US with contrast agents. In this essay, we review the spectrum of US appearances of hepatic hemangiomas on conventional gray-scale, power Doppler, and pulse-inversion harmonic US with contrast agents. 相似文献
15.
RATIONALE AND OBJECTIVES: The authors performed this study to estimate, by using published data, the sensitivity and specificity of computed tomographic (CT) angiography in the evaluation of suspected acute pulmonary embolism (PE). MATERIALS AND METHODS: Summary receiver operating characteristic (ROC) curve analysis was used to determine the sensitivity and specificity of CT angiography in the diagnosis of acute PE. Pulmonary angiography was used as the diagnostic standard of reference. The authors reviewed the results of 11 independent studies published in the English-language literature between January 1992 and June 1999. RESULTS: The sensitivity of CT angiography in the diagnosis or exclusion of PE in the central pulmonary arteries (to the level of the segmental pulmonary arteries) ranged from 0.74 to 0.81 on the basis of specificities of 0.89-0.91. The sensitivity of CT angiography in the diagnosis or exclusion of PE in all pulmonary arteries (to the level of the subsegmental pulmonary arteries) was 0.68 on the basis of a specificity of 0.91. CONCLUSION: On the basis of the studies in the current literature, most of which used 5.0-mm collimation and single-detector CT, CT angiography may be less accurate in the diagnosis of PE than previously reported. With improvements in data acquisition, particularly the use of thinner section collimation and multidetector CT, and in the increased use of workstations for data analysis, the accuracy and utility of CT angiography will require continued investigation. 相似文献
16.
Sang-Suk Han Seung-Kook Chang Jung-Hee Yoon Young-Joon Lee 《Korean journal of radiology》2001,2(4):197-203
Objective
To compare the clinical utility of contrast-enhanced color Doppler US in the differentiation of retinal detachment (RD) from vitreous membrane (VM) with that of various conventional US modalities, and to analyze the enhancement patterns in cases showing an enhancement effect.Materials and Methods
In 32 eyes examined over a recent two-year period, RD (n=14) and VM (n=18) were confirmed by surgery (n=28) or clinical follow-up (n=4). In all cases, gray-scale, color Doppler, and power Doppler US were performed prior to contrast injection, and after the intravenous injection of Levovist (Schering, Berlin) by hand for 30 seconds at a dose of 2.5 g and a concentration of 300 mg/mL via an antecubital vein, contrast-enhanced color Doppler US was performed. At Doppler US, the diagnostic criterion for RD and VM was whether or not color signals were visualized in membranous structures.Results
Diagnostic accuracy was 78% at gray-scale US, 81% at color Doppler US, 59% at power Doppler US, and 97% at contrast-enhanced color Doppler US. The sensitivity of color Doppler US to color signals in RD increased from 57% to 93% after contrast enhancement.The enhancement patterns observed were signal accentuation (n=3), signal extension (n=2), signal addition (n=3), and new signal visualization (n=5).Conclusion
Contrast-enhanced color Doppler US was the most accurate US modality for differentiating RD from VM, showing a significantly increased signal detection rate in RD. 相似文献17.
RATIONALE AND OBJECTIVES: The authors compared the time course and blood pool and hepatic enhancement of three different doses of liposomal iodixanol with those of iohexol. MATERIALS AND METHODS: A liposomal iodixanol formulation was prepared with 200 mg of iodine per milliliter total and 80 mg of iodine per milliliter encapsulated. Twelve normal New Zealand white rabbits divided into four groups received 75-, 100-, or 150-mg encapsulated iodine per kilogram doses of liposomal iodixanol or 2 mL/kg iohexol with 300 mg of iodine per milliliter. A liver section was scanned with serial computed tomography (CT) before the injection, immediately afterward, and at 1-minute intervals for 10 minutes. Region-of-interest measurements of the aorta and liver were plotted at each time point, and contrast enhancement was plotted as a function of time and iodine dose. RESULTS: All liposomal iodixanol doses produced greater liver enhancement than iohexol. Results were significant (P < .05) for 100 mg and 150 mg iodine per kilogram dose groups at time points beyond 2 minutes. Peak hepatic enhancement (change in attenuation) was 54.9 HU +/- 7.6 with iohexol, compared with 59.6 HU +/- 6.1, 73.3 HU +/- 3.6, and 104.1 HU +/- 8.8 for 75, 100, and 150 mg encapsulated iodine per kilogram doses, respectively. Hepatic enhancement increased rapidly after injection of liposomal iodixanol, plateauing 2-3 minutes later. Blood pool enhancement decreased rapidly. Steady-state liver enhancement with liposomal iodixanol increased linearly with dose. Aortic enhancement was greater with iohexol. CONCLUSION: Liposomal iodixanol yielded greater hepatic enhancement at lower total iodine doses than iohexol. Although liver enhancement occurred rapidly after injection, blood pool enhancement was brief. 相似文献
18.
Effects of scanning and reconstruction parameters on image quality in electron-beam CT angiography: coronary artery phantom study 总被引:2,自引:0,他引:2
RATIONALE AND OBJECTIVES: This study compared the image quality obtained with different scanning and reconstruction parameters for electron-beam computed tomographic (CT) angiography and sought optimal methods for visualizing the coronary artery lumen. MATERIALS AND METHODS: Electron-beam CT angiography with contrast material enhancement was used to image 35 branches of fresh postmortem swine coronary arteries. Different collimation widths, fields of view (FOVs), reconstruction kernels, and algorithms were employed to reconstruct the acquired raw data into CT angiographic images. Image quality was compared and analyzed. RESULTS: The contrast-to-noise ratios (C/Ns) for 1.5-, 2-, and 3-mm section thickness were 28.4 +/- 15.2, 31.9 +/- 9.3, and 33.8 +/- 14.5, respectively (P < .05). The lengths of visualized coronary artery lumina were significantly longer for 1.5-mm scanning (71.6 mm +/- 4.3) than for 2-mm (58.3 mm +/- 5.5) and 3-mm scanning (59.0 mm +/- 8.0) (P < .01). The C/Ns for 12.7-, 18.0-, and 26.0-cm FOV reconstruction were 32.8 +/- 9.9, 28.9 +/- 8.2, and 27.1 +/- 8.2, respectively (not significant), and the visualized luminal lengths were 76.1 mm +/- 12.5, 71.7 mm +/- 14.6, and 65.4 mm +/- 13.1, respectively (not significant). The highest C/N (48.2 +/- 13.3) was achieved with smooth kernels and a cone-beam algorithm, and the lowest (14.7 +/- 3.4) with very sharp kernels and a normal algorithm. Cone-beam algorithm images had significantly higher C/Ns than did normal algorithm images (P < .001), and they demonstrated longer coronary artery lumina (P < .01). CONCLUSION: Collimation width, FOV, reconstruction kernels, and algorithms are important in the processing of high-quality electron-beam coronary angiograms. A 1.5-mm collimation width, 12.7-cm FOV, cone-beam reconstruction algorithm, and very sharp kernels should help in obtaining the best image quality and depicting the longest segments of coronary artery lumen. 相似文献
19.
Reid JH 《Clinical radiology》2004,59(8):713-714
AIM: To assess whether the early regurgitation of intravenous contrast medium into the inferior vena cava (IVC) and/or hepatic veins on computed tomography (CT), indicates tricuspid regurgitation (TR), and if so, whether it be used to grade severity. MATERIALS AND METHODS: We identified 86 consecutive patients that had been investigated for possible pulmonary endarterectomy at Papworth Hospital. From these, 61 patients were selected in whom CT, transthoracic echocardiography, and right heart catheterization (RHC) had been performed within 6 weeks. Using an arbitrary visual scale, the degree of TR assessed by intravenous contrast-enhanced CT was compared with echocardiography. Results were analysed using a kappa weighted statistical test. In addition, CT and echocardiographic assessments of TR severity were correlated with pulmonary artery pressure measurements obtained by RHC (Spearman's rank correlation coefficient). RESULTS: CT assessment of TR had a sensitivity of 90.4% and a specificity of 100% in detecting echocardiographic TR. For TR graded as more than trivial by echocardiography, sensitivity of CT was 100%. With respect to RHC data, the correlation between severity assessment of TR between CT and echocardiography using the Kappa weighted coefficient was 0.56 (moderately good agreement). With respect to RHC data, the correlation between mean pulmonary pressure and TR grading on CT and echocardiography was r = 0.685 (p < 0.001) and r = 0.727 (p < 0.001), respectively. CONCLUSION: Early opacification of the IVC or hepatic veins on first-pass contrast-enhanced CT almost invariably indicates TR. There is moderately good agreement between CT and echocardiographic assessment of the severity of TR. Both CT and echocardiographic grading of TR correlate well with RHC measurements of pulmonary artery pressure. 相似文献
20.
R. N. Sener 《Neuroradiology》1994,36(2):117-120
The author studied a superficial temporal vein running anteroposteriorly within the occipitotemporal sulcus, the occipitotemporal vein, which, when prominent, could be thought to simulate a venous angioma on MRI. A cadaver (n=50), MRI (n=200), and CT (n=50) study was undertaken to examine the incidence, detectibility, size, location, and drainage of the occipitotemporal vein. It was an approximately 3 mm wide, 2–5 cm long structure. It was present in 83% of the cadavers (52% bilaterally), and clearly identifiable on 73% of the MRI (43% bilaterally), and 8% of the CT studies. In 18% of the cadavers the vein was totally absent, and it was not seen in 27% of the MRI examinations. The occipitotemporal vein can be distinguished from a venous angioma by its particular location and course, and by lack of intraluminal bright signal on spin-echo T2-weighted and/or contrast-enhanced T1-weighted images. In addition, venous angiomas are usually intraparenchymal, whereas the occipitotemporal vein is a superficial vessel. 相似文献