首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Lamivudine has been widely used in the treatment of HIV disease. A reliable, sensitive reversed phase high performance liquid chromatography (RP-HPLC) method was developed and validated for lamivudine in rabbit plasma. The method was developed on Hypersil BDS C-18 column (250 mm×4.6 mm, 5 μm) using a mobile phase of 0.25% Triethylamine buffer (pH 3.0): acetonitrile (70:30, v/v). The efficient was monitored by UV detector at 256 nm. The total run time was 15 min with a flow rate of 1.0 mL/min. Calibration curve was linear over the concentration range of 25–2000 ng/mL. The retention times of lamivudine and internal standard (Nelfinavir) were 8.78 min and 10.86 min, respectively. The developed RP-HPLC method can be successfully applied for the quantitative pharmacokinetic parameters determination of lamivudine in rabbit model.  相似文献   

2.
Didanosine is an effective antiviral drug in untreated and antiretroviral therapy-experienced patients with Human Immunodeficiency Virus (HIV). An automated system using on-line solid extraction and High Performance Liquid Chromatography (HPLC) with ultraviolet (UV) detection was developed and validated for pharmacokinetic analysis of didanosine in dog plasma. Modifications were introduced on a previous methodology for simultaneous analysis of antiretroviral drugs in human plasma. Extraction was carried out on C18 cartridges, with high extraction yield as stationary phase, whereas mobile phase consisted of a mixture of 0.02 M potassium phosphate buffer, acetonitrile (KH2PO4: acetonitrile: 96:4, v/v) and 0.5% (w/v) of heptane sulphonic acid. The pH was adjusted to 6.5 with triethylamine. All samples and standard solutions were chromatographed at 28 °C. For an isocratic run, the flux was 1.0 mL/min, detection was at 250 nm and injected volume was 20 μL. The method was selective and linear for concentrations between 50 and 5000 ng/mL. Drug stability data ranged from 96% to 98%, and limit of quantification was 25 ng/mL. Extraction yield was up to 95%. Drug stability in dog plasma was kept frozen at ?20 °C for one month after three freeze–thaw cycles, and for 24 h after processing in the auto sampler. Assay was successfully applied to measure didanosine concentrations in plasma dogs.  相似文献   

3.
An isocratic stability indicating RP-HPLC–UV method is presented for the determination of metaxalone (MET) in the presence of its degradation products. The method uses Dr. Maisch C18 column (250 mm×4.6 mm, 5 μm) with mobile phase consisting of acetonitrile–potassium dihydrogen orthophosphate buffer with 4 mL of 0.4% triethyl amine (pH 3.0; 10 mM) (58:42, v/v) at a flow rate of 1.0 mL/min. pH of the buffer was adjusted with o-phosphoric acid. UV detection was performed at 225 nm. The method was validated for specificity, linearity, precision, accuracy, limit of detection, limit of quantification and robustness. The calibration plot was linear over the concentration range of 1–100 μg/mL having a correlation coefficient (r2) of 0.999. Limits of detection and quantification were 0.3 and 1 μg/mL, respectively. Intra-day and inter-day precision (% RSD) was 0.65 and 0.79 respectively. The proposed method was used to investigate the degradation kinetics of MET under different stress conditions employed. Degradation of MET followed a pseudo-first-order kinetics, and rate constant (K), time left for 50% potency (t1/2), and time left for 90% potency (t90) were calculated.  相似文献   

4.
A rapid and sensitive liquid chromatography–tandem mass spectrometric (LC–MS/MS) assay method has been developed and fully validated for the simultaneous quantification of telmisartan and amlodipine in human plasma. Carbamazepine was used as an internal standard. Analytes and the internal standard were extracted from human plasma by solid-phase extraction technique using Waters Oasis® HLB 1 cm3 (30 mg) extraction cartridge. The reconstituted samples were chromatographed on a Hypurity advance C18 column (50 mm×4.6 mm, 5 μm) using a mixture of acetonitrile–5 mM ammonium acetate buffer (pH-4.0) (50:50, v/v) as the mobile phase at a flow rate of 0.8 mL/min. The calibration curve obtained was linear (r≥0.99) over the concentration range of 2.01–400.06 ng/mL for telmisartan and 0.05–10.01 ng/mL for amlodipine. Method validation was performed as per FDA guidelines and the results met the acceptance criteria. A run time of 2.5 min for each sample made it possible to analyze more than 400 human plasma samples per day. The proposed method was found to be applicable to clinical studies.  相似文献   

5.
Objective: To develop the representative fingerprint for the quality control of placenta polypeptide injection.MethodsThe chromatographic separation was performed using a Phenomenex Gemini C18 column (250 mm×4.6 mm, 5 μm) maintained at 30 °C. 0.1% aqueous trifluoroacetic acid (Solvent A) and acetonitrile contained 0.1% TFA (Solvent B) were used as mobile phase with a gradient elution. Detection wavelength was 280 nm with the sample injection volume of 50 μL; the flow rate was 1.0 mL/min. The fingerprints of different samples were investigated by similarity analysis.ResultsNine peaks were identified as the characteristic common peaks. The similarities of the fingerprints of the 10 batches of samples were above 0.992.ConclusionThis method showed high precision and good repeatability, and provided the basis for the improvement of the quality control of placenta polypeptide injection.  相似文献   

6.
Nateglinide has been widely used in the treatment of type-2 diabetics as an insulin secretogoga. A reliable, rapid, simple and sensitive reversed-phase high performance liquid chromatography (RP-HPLC) method was developed and validated for determination of nateglinide in rabbit plasma. The method was developed on Hypersil BDSC-18 column (250 mm×4.6 mm, 5 mm) using a mobile phase of 10 mM phosphate buffer (pH 2.5) and acetonitrile (35:65, v/v). The elute was monitored with the UV–vis detector at 210 nm with a flow rate of 1 mL/min. Calibration curve was linear over the concentration range of 25–2000 ng/mL. The retention times of nateglinide and internal standard (gliclazide) were 9.608 min and 11.821 min respectively. The developed RP-HPLC method can be successfully applied to the quantitative pharmacokinetic parameters determination of nateglinide in rabbit model.  相似文献   

7.
A rapid and simple high performance liquid chromatography (HPLC) method with a UV detection (241 nm) was developed and validated for estimation of eplerenone from spiked human plasma. The analyte and the internal standard (valdecoxib) were extracted with a mixture of dichloromethane and diethyl ether. The chromatographic separation was performed on a HiQSil C-18HS column (250 mm×4.6 mm, 5 μm) with a mobile phase consisting of acetonitrile:water (50:50, v/v) at flow rate of 1 mL/min. The calibration curve was linear in the range 100–3200 ng/mL and the heteroscedasticity was minimized by using weighted least squares regression with weighting factor 1/X.  相似文献   

8.
A validated ultra-performance liquid chromatography mass spectrometric method (UPLC–MS/MS) was used for the simultaneous quantitation of candesartan (CN) and hydrochlorothiazide (HCT) in human plasma. The analysis was performed on UPLC–MS/MS system using turbo ion spray interface. Negative ions were measured in multiple reaction monitoring (MRM) mode. The analytes were extracted using a liquid–liquid extraction (LLE) method by using 0.1 mL of plasma volume. The lower limit of quantitation for CN and HCT was 1.00 ng/mL whereas the upper limit of quantitation was 499.15 ng/mL and 601.61 ng/mL for CN and HCT respectively. CN d4 and HCT-13Cd2 were used as the internal standards for CN and HCT respectively. The chromatography was achieved within 2.0 min run time using a C18 Phenomenex, Gemini NX (100 mm×4.6 mm, 5 µm) column with organic mixture:buffer solution (80:20, v/v) at a flow rate of 0.800 mL/min. The method has been successfully applied to establish the bioequivalence of candesartan cilexetil (CNC) and HCT immediate release tablets with reference product in human subjects.  相似文献   

9.
A novel method for the simultaneous high-performance liquid chromatographic determination of nortriptyline hydrochloride and fluphenazine hydrochloride was developed and validated. Fluvastatin sodium was used as internal standard. The determination was performed on a Hypersil Gold C8 column (250 mm × 4.6 mm i.d., 5 μm particle size) at 25 °C; the mobile phase, consisting of a mixture of formic acid (0.1 M, pH 2.16)-methanol (33:67, v/v), was delivered at a flow rate of 1.1 mL/min and detector wavelength at 251 nm. The retention time of nortriptyline, fluphenazine and fluvastatin was found to be 5.11, 8.05 and 11.38 min, respectively. Linearity ranges were 5.0–1350.0 and 10.0–1350.0 μg/mL with limit of detection values of 0.72 and 0.31 μg/mL, for nortriptyline and fluphenazine, respectively. Results of assay and recovery studies were statistically evaluated for its accuracy and precision. Correlation coefficients (r2) of the regression equations were greater than 0.999 in all cases. According to the validation results, the proposed method was found to be specific, accurate, precise and could be applied to the simultaneous quantitative analysis of nortriptyline and fluphenazine.  相似文献   

10.
A high performance liquid chromatographic method was developed and validated for the quantitative determination of catechin in rat plasma and its pharmacokinetic study after intragastric administration of Catechu and Xiongdanjiangre Wan into SD rats. Plasma samples were prepared by protein precipitation using methanol–5% aqueous zinc sulfate (70:30, v/v) as precipitant. Chromatographic separation was achieved on Hypersil C18 column (250 mm×4.6 mm, 10 μm) with acetonitrile–water–triethylamine (6:94:0.3, v/v/v, pH 4.0±0.1, adjusted with phosphoric acid) as mobile phase, followed by a UV detection at 207 nm. Good linearity was obtained over the range of 0.143–7.15 mg/L of catechin, with correlation coefficient of 0.9992. The method was simple, sensitive, accurate and reproducible and has been successfully applied to the pharmacokinetic study of catechin in rat plasma.  相似文献   

11.
A simple, precise, accurate, and stability-indicating method is developed and validated for analysis of tetrahydrozoline hydrochloride in eye drop formulations. Separation was achieved on a reversed-phase C8 column (125 mm×4.6 mm i.d., 5 μm) using a mobile phase consisting of acetonitrile/phosphate buffer of pH 3.0 (20:80, v/v) at a flow rate of 1.0 mL/min and UV detection at 240 nm. This method is validated according to United States Pharmacopeia requirements for new methods, which include accuracy, precision, selectivity, robustness, and linearity and range. This method shows enough selectivity, accuracy, precision, and linearity and range to satisfy Federal Drug Administration/International Conference on Harmonization regulatory requirements. The current method demonstrates good linearity over the range of 0.025–0.075 mg/mL of tetrahydrozoline with r2 0.999. The average recovery of the method is 100.8% with a relative standard deviation of 0.47%. The degree of reproducibility of the results obtained as a result of small deliberate variations in the method parameters and by changing analytical operators has proven that the method is robust and rugged.  相似文献   

12.
A simple, precise, and rapid high-performance liquid chromatographic method was developed and validated for the simultaneous determination of vitexin-2″-O-glucoside, vitexin-2″-O-rhamnoside, rutin, vitexin, and hyperoside. The HPLC separation was performed using a Shim-pack VP-ODS C18 column (250 mm×4.6 mm i.d., 5 μm) with the isocratic mobile phase consisting of tetrahydrofuran/ acetonitrile/0.05% phosphoric acid solution (20:3:77, v/v/v), and the flow rate was set at 1.0 mL/min. UV detection was carried out at a wavelength of 360 nm and the whole analysis took 25 min. The method was linear in the range of 4.12–206.00 μg/mL for vitexin-2″-O-glucoside, 4.05–202.50 μg/mL for vitexin-2″-O-rhamnoside, 1.64–82.00 μg/mL for rutin, 1.74–87.00 μg/mL for vitexin, and 1.41–70.60 μg/mL for hyperoside with the correlation coefficient for each analyte more than 0.998. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.6 and 2 ng for vitexin-2″-O-glucoside, 0.6 and 2 ng for vitexin-2″-O-rhamnoside, 0.3 and 1 ng for rutin, 1 and 3 ng for vitexin, and 0.5 and 2 ng for hyperoside, respectively. Intra- and inter-day precision and accuracy (RSD) were less than 3%. The developed HPLC method was successfully applied to the analysis of five flavonoids in hawthorn leaves, hawthorn fruits, and the preparations containing hawthorn leaves or fruits.  相似文献   

13.
A selective, sensitive and high throughput liquid chromatography-tandem mass spectrometry (LC–ESI–MS/MS) method has been developed for separation and quantification of metoprolol enantiomers on a chiral Lux Amylose-2 (250 mm×4.6 mm, 5 μm) column. Solid phase extraction of (S)-(−)- and (R)-(+)-metoprolol and rac-metoprolol-d6 as an internal standard (IS) was achieved on Lichrosep DVB HL cartridges employing 200 μL human plasma. Both the analytes were chromatographically separated with a resolution factor of 2.24 using 15 mM ammonium acetate in water, pH 5.0 and 0.1% (v/v) diethyl amine in acetonitrile (50:50, v/v) as the mobile phase within 7.0 min. The precursor→product ion transitions for the enantiomers and IS were monitored in the multiple reaction monitoring and positive ionization mode. The method was validated over the concentration range of 0.500–500 ng/mL for both the enantiomers. Matrix effect was assessed by post-column analyte infusion experiment and the mean extraction recovery was greater than 94.0% for both the enantiomers at all quality control levels. The stability of analytes was evaluated in plasma and whole blood under different storage conditions. The method was successfully applied to a clinical study in 14 healthy volunteers after oral administration of 200 mg metoprolol tablet under fasting conditions. The assay reproducibility is shown by reanalysis of 68 incurred samples. The suitability of the developed method was assessed in comparison with different chromatographic methods developed for stereoselective analysis of metoprolol in biological matrices.  相似文献   

14.
Prevention of cross contamination with active pharmaceutical ingredients is crucial and requires special attention in pharmaceutical industries. Current method validation describes the determination of Nabumetone (NAB) residue on a stainless steel surface using swab sampling with a sensitive HPLC-DAD analysis. The acceptance limit was decided as 2 μg swab per 100 cm2. Cotton swabs impregnated with extraction solution were used to determine residual drug content. Recoveries were 90.88%, 91.42%, and 92. 21% with RSD ranging from 2.2% to 3.88% at three concentration levels. Residual concentration was found to be linear in the range of 0.1–4.56 μg/mL, when estimated using a Phenomenex Luna C18 (25 cm×5 μm×4.6 mm i.d.) column at 1.0 mL/min flow rate and 230 nm. The mobile phase consisted of a mixture of methanol:acetonitrile:water (55:30:15, v/v/v). The LOD and LOQ for NAB were found to be 0.05 and 0.16 μg/mL, respectively. The validated method was found to be simple, selective and sensitive for demonstration of cleaning validation of NAB residues on a stainless steel surface.  相似文献   

15.
A simple, sensitive, and specific liquid chromatography tandem mass spectrometry (LC-MS/MS) method was developed for the quantification of desloratadine (DL) in human plasma using desloratadine-d5 (DLD5) as an internal standard (IS). Chromatographic separation was performed using an Xbridge C18 column (50 mm×4.6 mm, 5 μm) with an isocratic mobile phase composed of 10 mM ammonium formate: methanol (20:80, v/v), at a flow rate of 0.7 mL/min. DL and DLD5 were detected with proton adducts at m/z 311.2→259.2 and 316.2→264.3 in multiple reaction monitoring (MRM) positive modes, respectively. Liquid–liquid extraction (LLE) method was used to extract the drug and the IS. The method was validated over a linear concentration range of 5.0–5000.0 pg/mL with a correlation coefficient of (r2)≥0.9994. This method demonstrated intra- and inter-day precision within 0.7–2.0% and 0.7–2.7%, and an accuracy within 101.4–102.4%, and 99.5–104.8%. DL was found to be stable throughout the freeze–thaw cycles, bench-top, and postoperative stability studies. This method was successfully applied in the analysis of plasma samples following oral administration of DL (5 mg) in 35 healthy Indian male human volunteers under fasting conditions.  相似文献   

16.
A simple, sensitive and high throughput ultra performance liquid chromatography tandem mass spectrometry method has been developed for the determination of mycophenolic acid in human plasma. The method involved simple protein precipitation of MPA along with its deuterated analog as an internal standard (IS) from 50 µL of human plasma. The chromatographic analysis was done on Acquity UPLC C18 (100 mm×2.1 mm, 1.7 µm) column under isocratic conditions using acetonitrile and 10 mM ammonium formate, pH 3.00 (75:25, v/v) as the mobile phase. A triple quadrupole mass spectrometer operating in the positive ionization mode was used for quantitation. In-source conversion of mycophenolic glucuronide metabolite to the parent drug was selectively controlled by suitable optimization of cone voltage, cone gas flow and desolvation temperature. The method was validated over a wide concentration range of 15–15000 ng/mL. The mean extraction recovery for the analyte and IS was >95%. Matrix effect expressed as matrix factors ranged from 0.97 to 1.02. The method was successfully applied to support a bioequivalence study of 500 mg mycophenolate mofetil tablet in 72 healthy subjects.  相似文献   

17.
A highly selective and stability-indicating HPLC-method, combined with appropriate sample preparation steps, is developed for β-artemether assay and profiling of related impurities, including possible degradants, in a complex powder for oral suspension. Following HPLC conditions allowed the required selectivity: a Prevail organic acid (OA) column (250 mm×4.6 mm, 5 μm), flow rate set at 1.5 mL/min combined with a linear gradient (where A=25 mM phosphate buffer (pH 2.5), and B=acetonitrile) from 30% to 75% B in a runtime of 60 min. Quantitative UV-detection was performed at 210 nm. Acetonitrile was applied as extraction solvent for sample preparation. Using acetonitrile–water mixtures as extraction solvent, a compartmental behaviour by a non-solving excipient-bound fraction and an artemether-solubilising free fraction of solvent was demonstrated, making a mobile phase based extraction not a good choice. Method validation showed that the developed HPLC-method is considered to be suitable for its intended regulatory stability-quality characterisation of β-artemether paediatric formulations. Furthermore, LC–MS on references as well as on stability samples was performed allowing identity confirmation of the β-artemether related impurities. MS-fragmentation scheme of β-artemether and its related substances is proposed, explaining the m/z values of the in-source fragments obtained.  相似文献   

18.
A fast, simple and sensitive high performance liquid chromatographic (HPLC) method has been developed for determination of 10α-methoxy-6-methyl ergoline-8β-methanol (MDL, a main metabolite of nicergoline) in human plasma. One-step liquid–liquid extraction (LLE) with diethyl ether was employed as the sample preparation method. Tizanidine hydrochloride was selected as the internal standard (IS). Analysis was carried out on a Diamonsil ODS column (150 mm×4.6 mm, 5 μm) using acetonitrile–ammonium acetate (0.1 mol/L) (15/85, v/v) as mobile phase at detection wavelength of 224 nm. The calibration curves were linear over the range of 2.288–73.2 ng/mL with a lower limit of quantitation (LLOQ) of 2.288 ng/mL. The intra- and inter-day precision values were below 13% and the recoveries were from 74.47% to 83.20% at three quality control levels. The method herein described was successfully applied in a randomized crossover bioequivalence study of two different nicergoline preparations after administration of 30 mg in 20 healthy volunteers.  相似文献   

19.
A selective precolumn derivatization liquid chromatography–tandem mass spectrometric (LC–MS/MS) method for the determination of glucosamine in human plasma and urine has been developed and validated. Glucosamine was derivatized by o-phthalaldehyde/3-mercaptopropionic acid. Chromatographic separation was performed on a Phenomenex ODS column (150 mm×4.6 mm, 5 μm) using linear gradient elution by a mobile phase consisting of methanol (A), and an aqueous solution containing 0.2% ammonium acetate and 0.1% formic acid (B) at a flow rate of 1 mL/min. Tolterodine tartrate was used as the internal standard (IS). With protein precipitation by acetonitrile and then the simple one-step derivatization, a sensitive bio-assay was achieved with the lower limit of quantitation (LLOQ) as low as 12 ng/mL for plasma. The standard addition calibration curves suitable for clinical sample analysis showed good linearity over the range of 0.012–8.27 μg/mL in plasma and 1.80–84.1 μg/mL in urine. The fully validated method has been successfully applied to a pharmacokinetic study of compound glucosamine sulfate dispersible tablets in health Chinese volunteers receiving single oral doses at 500, 1000 and 1500 mg of glucosamine sulfate, as well as multiple oral doses of 500 mg t.i.d. for 7 consecutive days.  相似文献   

20.
A simple, specific, precise, sensitive and rapid reverse phase-HPLC method was developed for determination of ketorolac enantiomers, a potent nonnarcotic analgesic in pharmaceutical formulations. The method was developed on a chiral AGP column. Mobile phase was 0.1 M sodium phosphate buffer (pH 4.5): Isopropanol (98:2, v/v), at a flow rate of 1 mL/min with run time of 15 min. Ultraviolet detection was made at 322 nm. The linearity range was 0.02–10 μg/mL for each of the enantiomers. The mobile phase composition was systematically studied to find the optimum chromatographic conditions. Validation of the method under the conditions selected showed that it was selective and precise and that the detector response was linear function of ketorolac.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号