首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 203 毫秒
1.
目的 探讨髋臼后柱的解剖结构,以寻求-安全的置钉途径.方法 取15具骨盆标本(共30髋),确定髋臼缘最上点为A点,最下点为B点,取其A、B中点为C点.取坐骨大切迹顶点为A'点,坐骨棘顶点为B'点,取A'、B'中点为C'点.连接C、C'两点.经过C、C'线且与后柱表面垂直的平面为起始平面(髋臼中部平面).平行于起始平面,在起始平面上下各作2个横断面,段面间隔为10mm.共获得包括髋臼前柱、后柱在内的5个断面.在每一断面上测量髋臼宽、后柱宽并测量距髋臼缘10、20mm处置入螺钉的安全角度和长度.测量结果用(x±s)表示.结果 ①髋臼中部平面髋臼最宽为:(20.7±1.5)mm.但该断面后柱最窄为:(33.9±2.5)mm.②距髋臼后缘10mm的各断面进钉的最小角度为(52.3±5.5)°,最小进钉长度为(28,9±2,7)mm.距髋臼后缘20mm的各断面进钉的最小角度为(81.4±5.0)°,最小进钉长度为(35.9±4.1)mm.结论 在髋臼后柱距臼缘10、20mm处角度分别不大于50°、80°,深度分别不大于28、35mm可以安全的放置螺钉.  相似文献   

2.
Wang XQ  Zhang W  Sun S  Zhang JL  Wang J  Li W 《中华外科杂志》2006,44(24):1700-1703
目的研究髋臼前柱钢板内固定技术中螺钉的最佳进钉点、方向和长度,预防发生螺钉穿入关节内的严重并发症。方法取成年男性半骨盆标本20个,分别测量髋臼前、后缘到髂前下棘、髂耻隆起和耻骨结节的距离,确定和制作髋臼前柱系列断面,分别测量各断面上各进钉点的安全进钉角度,将测量数据输入到SPSS10.0软件进行统计学分析。结果髋臼前缘到髂前下棘、髂耻隆起和耻骨结节的距离分别为(25.4±1.4)mm,(11.8±0.7)mm和(37.4±1.5)mm,后缘到髂前下棘和髂耻隆起的距离分别为(15.5±0.9)mm和(29.1±1.6)mm。在各断面距离骨盆界线0.5cm点、1.0cm点和1.5cm点上螺钉的安全进钉角度的最大值分别为(8.2±2.2)°、(14.9±3.4)°和(26.1±4.5)°。结论在前柱髋臼区使用钢板内固定时,可以采用3种方法避免螺钉穿入关节内。第一种方法是使用短螺钉,螺钉方向随意;第二种方法是使用长螺钉紧贴骨盆界线进钉,方向平行于四方区;第三种方法为根据不同的进钉点选择不同的进钉角度和长度。  相似文献   

3.
髋臼后柱支持钢板的临床解剖学研究   总被引:14,自引:2,他引:12  
目的 探讨在髋臼骨折手术中放置后柱支持钢板时如何防止螺钉穿入髋关节内。方法 将髋臼后柱的危险区分为山顶区、山腰上区、山腰下区和山脚区。在 2 0例髋臼CT扫描图像和 1例骨盆标本的后柱上做A、B、C、D和E点 ,并测量各点的进钉角度和深度 ,测量结果用 -x±s表示。结果 通过CT图像测量的a、b、c、d角和e角分别为 4 1 5 8°± 4 5 6°、 71 92°±7 87°、 94 6 7°± 6 0 1°、 113 5 8°± 5 81°和 12 8 0 4°± 4 78°;EA长度、A深度、B深度、C深度、D深度和E深度分别为 4 3 2 0± 3 4 3mm、 36 6 0± 4 99mm、 35 80± 3 77mm、 31 30± 2 4 5mm、 30 4 0± 2 84mm和 35 6 0± 2 99mm。结论 髋臼骨折手术中A、B、C、D和E点的钉后柱角分别为 30°、 6 0°、 80°、 10 0°和 12 0°左右。在髋臼后柱的不同区域螺钉应采取不同的进钉角度和深度。  相似文献   

4.
目的通过对第三、四骶骨螺钉应用的解剖学测量,探讨第三、四骶骨螺钉应用的安全性。方法 32具成人骶骨标本。设定A点、B点和C点为螺钉进钉点,分别位于相邻骶后孔内侧缘连线的中点,相邻骶后孔连线的中点,经相邻骶后孔连线中点的水平线与骶外侧嵴的交点。D1、D2、D3、α和β、分别为水平面上骶骨内侧置钉,垂直置钉和外侧置钉的钉道长度,内侧置钉和外侧置钉最大偏移角度。d1、d3、θ和φ分别为矢状面上骶骨头侧置钉和尾侧侧置钉钉道长度,头侧置钉和尾侧置钉最大偏移角度。结果 S3螺钉在A和B点进钉,水平面上偏向外侧小于45.21°±10.66°,矢状面上偏向头侧小于8.50°±3.53°;C点进钉,水平面上偏向内侧小于52.00°±7.55°,矢状面上偏向头侧小于19.05°±6.36°。S4螺钉在A和B点进钉,水平面上偏向外侧小于49.50°±9.53°,矢状面上偏向头侧小于12.00°±4.24°,偏向尾侧小于14.00°±2.83°;C点进钉,水平面上偏向内侧小于66.19°±8.14°,矢状面上偏向头侧小于13.50°±3.54°,偏向尾侧小于28.50°±2.12°。结论了解第三、四骶骨的解剖结构和精确的螺钉放置可以保证骶骨螺钉固定成功。  相似文献   

5.
《中国矫形外科杂志》2017,(16):1495-1501
[目的]测量经皮逆行髋臼前柱螺钉内固定的应用解剖参数。[方法]收集本院2015年6月~2016年1月完整骨盆CT扫描数据男女各15例(男女各30侧半骨盆),应用Mimics计算机辅助外科软件,重建骨盆三维模型。模拟手术逆行置入髋臼前柱虚拟螺钉,调整好螺钉位置后测量螺钉长度、进钉点、进钉方向;通过软件的重切割功能,制作35层髋臼前柱系列截面,测量截面中螺钉所通过位置(即钉道)的直径。[结果]髋臼前柱可置入螺钉的最大工作长度男女分别为(119.79±8.71)mm、(104.10±5.84)mm;进钉点(P)到耻骨上支上缘(A)、耻骨联合(B)的垂直距离男性分别为(19.69±2.79)mm、(18.80±3.35)mm,女性分别为(18.27±2.13)mm、(22.92±3.34)mm;螺钉与冠状面、矢状面、横切面的夹角男性依次为(16.18±5.37)°、(41.76±4.78)°、(43.30±5.55)°,女性依次为(17.16±5.53)°、(43.12±3.90)°、(41.36±4.59)°;螺钉长度和PB男女之间的差异具有统计学意义(P<0.05),进钉方向和PA男女之间的差异无统计学意义(P>0.05)。前柱钉道最狭窄处位于第5层,该层截面中钉道直径男女分别为(11.43±1.24)mm、(8.75±0.95)mm,男女之间差异具有统计学意义(P<0.05)。[结论]作者建议国人男性使用直径为6.5 mm的螺钉,女性使用直径为5.5 mm的螺钉;进钉点男女稍有不同,在螺钉经过耻骨上支的中部和髂窝平面处两个狭窄地方时,应加强监视。  相似文献   

6.
目的研究改良Stoppa入路拉力螺钉经前柱固定髋臼后柱、后壁的解剖通路。方法收集30例正常成人半骨盆CT数据并重建骨盆髋臼模型,在改良Stoppa入路可见范围内模拟螺钉由髋臼前柱向后柱、后壁置入。测量参数:入钉点与髋臼顶点距离(H1),入钉点与真骨盆内缘的距离(H2),由入钉点向髋臼后壁下部置入螺钉的长度(L1),由入钉点垂直真骨盆面向髋臼后壁中部置入螺钉的长度(L2),由入钉点向髋臼后壁上部置入螺钉的长度(L3),由入钉点向髋臼后柱坐骨小切迹部置入螺钉的长度(L4);髋臼下部螺钉与髋臼后壁中部置钉夹角(A1),髋臼上部螺钉与髋臼后壁中部置钉夹角(A2),髋臼后柱坐骨小切迹螺钉与髋臼后壁中部螺钉夹角(A3),髋臼后柱坐骨小切迹螺钉与进钉点和骶髂关节前缘与真骨盆内缘交点连线的夹角为(A4),髋臼后柱坐骨小切迹螺钉与髂骨翼平面夹角为(A5)。结果男性组模拟置钉后L1、L2、L3、L4明显大于女性组,差异有统计学意义(P 0.05);但2组H1、H2、A1、A2、A3、A4、A5比较差异无统计学意义(P0.05)。4例3D打印模型(2例男性髋臼及2例女性髋臼)经自制导向器置钉后验证成功。结论在改良Stoppa入路可显露的骨盆范围内,由髋臼前柱固定髋臼后柱、后壁的螺钉安全通路存在,并且经3D打印模型置钉验证成功。  相似文献   

7.
目的 :探讨枢椎以横突后支与下关节突交界处为解剖标志行椎弓根置钉的可行性,为临床应用提供参考。方法:30具湿性成人颈椎尸体标本,显露并以枢椎横突后支与下关节突外侧缘交界处作为参照点标志。经该解剖标志作水平线,以椎弓根内、外侧缘与侧块交界处连线的中点作纵垂线,以两线的交点偏外1~2mm处为进钉点。分别测量枢椎横突后支的宽度,进钉点与该解剖标志、C2神经根、横突孔内下壁和椎管内侧壁的距离。取上述进钉点,经枢椎双侧椎弓根以内倾角25°~30°、头倾角20°~25°共置入60枚螺钉,再行CT扫描观察钉道的完整性,测量置入螺钉的内倾角和头倾角,统计螺钉偏置率。结果:所有解剖参数及螺钉角度左、右侧比较差异均无统计学意义(P0.05),双侧数据合并后计算总体平均数值。枢椎横突后支的宽度为5.13±0.15mm,进钉点与解剖标志、C2神经根、横突孔内下壁和椎管内侧壁的距离分别为5.73±0.62mm、4.04±0.21mm、5.32±0.49mm和4.94±0.38mm。螺钉内倾角和头倾角分别为28.4°±3.1°和22.5°±2.9°。60枚螺钉中,共有4枚螺钉偏置进入横突孔或椎管,螺钉偏置率为6.7%(4/60);4枚螺钉过长穿破椎体前缘骨皮质。结论:枢椎以横突后支与下关节突交界处作为椎弓根置钉进钉点的参照点解剖标志是可行的,但因解剖差异仍存在螺钉误置的可能。  相似文献   

8.
目的比较Ⅲ代经口寰枢椎复位钢板(TARP-Ⅲ)手术中C2经口前路关节突螺钉(C2TOAMS)/C2经口前路经椎弓根螺钉(C2TOTPS)CT置钉参数与解剖测量数据之间的差异,分析实际置钉过程中存在的问题。方法收集广州军区广州总医院骨科医院2008年3月至2012年8月行TARP-Ⅲ手术的75例成年患者的术后薄层CT数据,获得C2TOAMS/C2TOTPS临床实际置钉参数。由2位测量者分别在不同平面上进行测量,计算观察者内和观察者间组内相关系数(ICC);并将上述参数与前期解剖学测量结果进行对比,同时比较左右两侧测量结果的差异。结果临床实际置入的C2TOAMS/C2TOTPS进钉点距枢椎侧块关节面的平均距离(双侧)为4.6 mm,左右两侧进钉点距正中矢状面的平均距离分别为7.6 mm和9.3 mm,左右两侧实际骨性钉道平均长度分别为16.3 mm和17.3 mm;左右两侧平均进钉外展角分别为16.9°和15.8°,平均进钉下倾角分别为—1.2°和0.2°。CT测量可靠性评价:观察者内ICC为0.94、0.95,观察者间ICC为0.94。结论 C2TOAMS/C2TOTPS实际进钉点和进钉方向变异较大,下倾角不够,个性化术前计划和术中X线引导并不能满足C2TOAMS/C2TOTPS精确置钉的需要,应辅以其他引导方式,以进一步提高经口枢椎螺钉置钉的准确度和安全性。  相似文献   

9.
髋臼在前柱投影的解剖学研究   总被引:4,自引:0,他引:4  
目的探讨髋臼前柱的解剖学结构和螺钉放置的安全角度范围.方法取20具骨盆标本,在X线透视下确定髋臼上缘距髂前下棘顶点和髋臼下缘距髂外血管鞘外缘与骨盆缘交点的距离,CT垂直扫描前柱,测量距髋臼上缘0.5~4.0 cm(每0.5 cm测1次)的CT断面上前柱宽、髋臼宽.根据髋臼在前柱表面的投影,将前柱分为髋臼区、相对危险区和危险区,并测量距骨盆缘1 cm处φ2.5 cm螺钉进钉的安全角度.结果髋臼上缘在髂前下棘顶点上(1.1±0.1)cm,髋臼下缘在髂外血管鞘外缘与骨盆缘交点下(1.7±0.2)cm,距髋臼上缘0.5、1.0、1.5、2.0、2.5、3.0、3.5、4.0 cm的CT断面上,前柱平均宽分别为(55.7±4.8)、(54.4±2.0)、(50.5±3.7)、(41.3±3.0)、(39.1±4.6)、(35.2±5.7)、(31.7±5.6)、(30.8±3.4)mm;髋臼宽分别为(28.2±6.2)、(34.7±5.5)、(36.8±5.2)、(34.8±2.7)、(37.0±4.2)、(33.2±5.1)、(29.6±5.7)、(28.0±3.9)mm;距髋臼上缘0.5 cm断面进钉安全角度应<87°±8°;距髋臼上缘1.0cm断面进钉的安全角度应<76°±7°;距髋臼上缘1.5 cm断面进钉的安全角度应<69°±7°;距髋臼上缘2.0 cm断面进钉的安全角度应<63°±7°.结论髋臼中心部不能放置螺钉,中心部以上可以放置螺钉,进钉角度应<63°±7°.  相似文献   

10.
目的 探讨顺行拉力螺钉固定髋臼后柱骨折的进钉参数,为进钉瞄准器的研制提供应用解剖学基础.方法 收集40例正常成人(男20例,女20例)骨盆的螺旋CT扫描数据,重建骨盆三维模型.经髂前上棘(A)和髂后上棘(B)的骨性最突出点的连线中点M做一平面(γ)垂直于AB,在髋臼后柱的γ截面上模拟置人虚拟圆柱体,该圆柱体从髂翼内侧的穿出点(O)即为拉力螺钉的入钉点.在弓状缘上取点D,使OD成为入钉点与弓状缘之间的最短距离,连结OD,G点为骶髂关节最前缘,连结DG.测量OD、DG的距离、置入拉力螺钉的长度、拉力螺钉与冠状面的夹角(α)及与矢状面的夹角(β). 结果 OD距离平均为(13.62±2.19)mm,DG距离平均为(15.27±4.01) mm,能置入拉力螺钉的长度平均为(116.65±7.19) mm,α夹角平均为15.47°±4.01°,β夹角平均为6.65°±2.93°.男、女性在DG距离、β夹角、置入拉力螺钉的长度方面差异均有统计学意义(P<0.05),而在OD距离及α夹角方面差异均无统计学意义(P>0.05). 结论 根据髋臼后柱顺行拉力螺钉置钉的解剖学参数,术中置入合适长度的拉力螺钉是可行的,可作为研发进钉瞄准器的应用解剖学依据.  相似文献   

11.
髋臼骨折不同内固定方式的生物力学稳定性研究   总被引:1,自引:1,他引:0  
目的:探讨3种不同的内固定方式固定髋臼双柱骨折的生物力学稳定性。方法 :16个髋关节标本随机分为4组,其中1组完整髋臼作为正常对照组,其余3组模拟双柱骨折后,分别按下列方法内固定:前柱螺钉加后柱钢板(SP),前柱钢板加后柱螺钉(PS),后柱双钢板(PP)。通过连续垂直加载,记录骨折的位移程度和髋臼的接触特性。结果:在载荷800 N时,SP、PS和PP 3组髋臼平均纵向位移位分别为(1.92±0.81)、(2.09±1.13)、(3.44±0.75)mm,SP与PP组比较差异有统计学意义(P=0.033)。SP、PS和PP 3组髋臼平均横向位移位分别为(0.63±0.33)、(0.77±0.45)、(1.44±0.56)mm,SP组与PS组相比较差异有统计学意义(P=0.047)。800 N载荷压力下,在髋臼负重区,与正常对照组相比,SP、PS和PP组分别接触面积增加了6%、9%和27%,其中PP组与正常对照组差异存在统计学意义(P=0.027);在髋臼负重区,与正常对照组相比,SP、PS和PP组平均应力分别增加了4%、29%和39%,其中PP组与正常对照组差异存在统计学意义(P=0.003)。结论:在生物力学的稳定性和接触性方面,前柱螺钉加后柱钢板有较大优势。  相似文献   

12.
不同路径髂骨钉钉道的CT影像学研究   总被引:2,自引:1,他引:1  
目的:研究髂骨钉的最佳路径,为腰骶骨盆重建手术提供参考依据。方法:2009年2月至8月,选门诊或住院因各种原因进行骨盆CT扫描及三维重建并且无阳性表现的50例患者影像学资料进行研究,男28例,女22例;年龄19~65岁,平均41.2岁。设计4条路径,A、B、C路径均以CLIC点(Chiotic线与后髂嵴的交叉点,位于髂后上棘上方24mm处)为起点,方向分别为髋臼上缘、髂前下棘、髋臼中心;D路径以髂后上棘起点,指向髂前下棘。对每条路径中不同钉道的长度及钉道中两处狭窄点的骨板厚度进行数据分析。结果:A(CLIC点到髋臼上缘)、B(CLIC点到髂前下棘)、D(髂后上棘与髂前下棘)路径钉道长度相当,但A路径髂骨板厚度明显较B、D路径大。A、C(CLIC点到髋臼中心)路径髂骨板厚度无明显差异,但A路径通道长度明显大于C路径。结论:A路径即从CLIC点到髋臼上缘方向的髂骨钉钉道路径最长且髂骨板最厚,能够容纳相对最长最粗的髂骨钉,又能承受的拉力最大,是最理想的髂骨钉钉道。  相似文献   

13.
ObjectiveThe objective of the present paper was to investigate the value of obturator oblique and pubic ramus inlet views in guiding anterior column acetabular screw insertion.MethodsWe collected pelvic CT scans at the diagnostic imaging center of our hospital between 2017 and 2019. Virtual three‐dimensional (3D) models of the pelvis were created based on the CT scans. Then the transparency was adjusted to 30%. Two identical copies of the 3D model data were made. 3D model replications were divided into a control group and an experimental group. In the control group, the screw was inserted into the anterior acetabular column using obturator‐outlet and iliac‐inlet views. In the experimental group, the screw was guided under obturator oblique and pubic ramus inlet views. Based on whether the screw penetrated the hip joint and/or exited the pubic ramus, models were divided into three grades. Grade I: the screw travels completely within the anterior column bone corridor; Grade II: the screw exits the superior pubic ramus, but the length of the screw outside the channel does not exceed 1/2 of the anterior column; Grade III: the screw exits the superior pubic ramus and the length of the screw outside the corridor exceeds 1/2 of the anterior column. We compared the screw placement quality of the two groups and analyzed differences between genders. In addition, the distance between the screws and the acetabulum was recorded and compared among the two groups.ResultsA total of 110 hemipelves were selected, including those of 80 men and 30 women, with an average age of 46.76 ± 14.26 years. In the control group, the screw quality of 64 models (58.2%) was Grade I. In the experimental group, 94 models (85.5%) had Grade I screw placement quality. Grade II screw placement quality accounted for 18.2% of the control group and 7.3% of the experimental group. In the control and the experimental groups, there were 26 and 8 cases with Grade III screw placement quality, respectively. The quality of screw placement in the experimental group was significantly better than that in control group, and the difference between the two groups was statistically significant (P < 0.01). The distance between the screw and the acetabulum in the control group and experimental group was 0.92 ± 0.49 mm and 2.78 ± 1.15 mm, respectively. The difference between the two groups was statistically significant.ConclusionAnterior column acetabular screws can be inserted successfully and more accurately using the obturator oblique and pubic ramus inlet views.  相似文献   

14.
Introduction and importanceAnterior column plate combined with posterior column screws have been effectively used for treatment of displaced transverse acetabular fractures. This article presents the use of 3D-printed technology for customising a guide template to appropriately place posterior column screw.Case presentationA 50-year-old female suffered displaced juxtatectal fracture of the right acetabulum. A personalised guide for antegrade posterior column screw placement was designed based on the data of her pelvic CT-scan. This guide and a prototype of her right acetabulum - created by mirroring the intact left acetabulum - were 3D-printed for preoperative evaluation and pre-contouring of reconstruction plate. Modified Stoppa approach and additional lateral window were used for direct reduction, anterior column plate and posterior column lag screw fixation. Post-operative CT-scan showed good reduction and nearly ideal screw position.Clinical discussionAnterior column plate and antegrade posterior column screw could provide joint stability and early mobilisation for displaced transverse acetabular fractures. However, determination of optimal entry point, direction and length for screw insertion is still technically demanding. The 3-D reconstruction images of hemipelvic specimen allowed us to identify the safe bone corridor, design a drill guide to put the proper guide pin and conduct preoperative trial. All those resulted in appropriate real screw fixation with reduction of soft tissue damage, X-ray exposure and time of operation.ConclusionThe use of 3D-printed personalised guide for posterior column screw fixation is a promising alternative option for treatment of displaced transverse acetabular fracture where 3D-navigation system is not available.  相似文献   

15.
目的:探讨通过3D打印技术明确髋臼发育不良类型选择最合适的髋臼成形术治疗脑瘫儿童髋关节脱位的适应证和临床疗效。方法:自2019年7月至2019年12月,采用3D打印技术辅助髋臼成形术治疗7例脑瘫儿童髋关节脱位,其中男3例,女4例;年龄3~8岁;左侧3例,右侧2例,双侧2例;2例髋关节半脱位,5例髋关节脱位。患儿术前均行骨盆-双股骨全长CT扫描。通过3D打印重建技术,判断髋臼发育不良类型:前侧2髋,前外2髋,外上1髋,后侧2髋,后外1髋,无发育不良1髋(未做髋臼成形术)。对8髋分别进行Pemberton,Dega和San Diego手术模拟,寻找最合适的手术方式并手术。比较术前和末次随访外移比例(migration percentage,MP),髋臼指数(acetabular index,AI),中心边缘角(center-edge angle,CEA),Shenton线和粗大运动功能分级(gross motor function classification system,GMFCS)的变化,并记录其并发症情况。结果:术后患者伤口愈合良好,无并发症发生。7例患者获随访,时间18~24个月。8髋Ⅰ期行软组织松解+股骨近端内翻去旋转短缩截骨+髋关节复位+髋臼成形术;1髋Ⅰ期行软组织松解+股骨近端内翻去旋转短缩截骨+髋关节复位术。MP由术前的58%~100%降至末次随访时的0~17.9%。AI由术前的25.0°~47.6°降至末次随访时的11.1°~25.3°。CEA由术前的0°改善至末次随访时的21.1°~48.5°。Shenton''线均由中断变为连续。其中5例GMFCS分级下降1级,2例无变化。结论:脑瘫儿童髋关节脱位中髋臼发育不良的类型多样,髋臼成形术适用范围也有差异,借助3D打印技术计算机模拟手术可选择最合适的手术方式并判断治疗效果,对脑瘫儿童髋关节脱位做到个体化、精准化治疗。  相似文献   

16.
枕寰枢后路经关节螺钉内固定的可行性研究   总被引:5,自引:2,他引:5       下载免费PDF全文
目的明确后路寰枕关节经关节螺钉固定的螺钉、进钉点植入角度、钉道角度和螺钉长度。探讨枕颈部经关节螺钉内固定技术的手术指征效果和并发症。方法在 2 0例含有完整寰枕关节的干燥骨性标本上 ,直视下进行后路寰枕关节经关节克氏针植入 ,在头尾侧和侧位X线片上测量理想的钉道角度和钉道长度。 30例正常成年人的寰枕关节进行三维CT重建 ,同时测量后路寰椎关节经关节螺钉钉道角度的可调范围。 12例新鲜枕颈部标本进行后路枕颈部关节螺钉内固定 ,术后行正、侧位X线片和三维CT重建 ,以验证螺钉位置。结果干燥标本模拟X线片测量 ,寰枕关节螺钉的钉道在矢状面上呈上倾 ,在冠状面上呈内倾 ,钉道的理想角度为 :在矢状面上倾角为 5 3.3°± 3.4° ,在冠状面内倾角为 2 0 .0°± 2 .6°。螺钉钉道长度为 (2 9.2 8± 2 .4 6 )mm。依据三维CT重建后测量 ,钉道方向与矢状面上倾角存在一个可调范围 ,一般为 4 9.6°± 2 .0°,与冠状面的内倾角也存在一个可调范围 ,一般为 4 0 .4°± 3.4°。齿突与枕髁前方最高点间距为 9.80~ 17.7mm ,平均 (13.4 3± 1.93)mm。寰枕关节关节螺钉内固定 ,影像学检查显示 ,螺钉钉道均经过寰枕关节 ,未进入神经管。结论寰枕关节后路经关节螺钉植入存在一定的方向性 ,钉道长度和钉道角度  相似文献   

17.
目的:通过CT测量探讨枢椎峡部螺钉固定技术的安全性和可行性。方法:收集2016年1月至2019年12月进行全颈椎CT检查的137例结构完整的上颈椎CT数据,其中男71例,女66例;年龄22~65(41.8±17.4)岁。通过Mimics19.0软件测量峡部螺钉技术相关的解剖学数据,包括峡部宽度、峡部垂直长度、峡部垂直高度、峡部螺钉通道长度、峡部螺钉通道头倾角度。并分析各项指标之间的相关性。结果:枢椎峡部宽度(9.05±1.63) mm,垂直长度(11.21±1.43) mm,垂直高度(17.53±2.93) mm。螺钉通道长度为(19.07±3.20) mm。峡部螺钉通道长度>14 mm的占94.53%,14~16 mm的占82.12%,16~18 mm的占63.14%,18~20 mm的占39.78%。螺钉通道的头倾角度为30°~68°,平均(46.06±8.06)°。螺钉通道长度和头倾角度呈高度正相关(r=0.965,P=0.000)。峡部垂直长度和螺钉通道长度,峡部垂直长度和螺钉的头倾角度之间都呈轻度正相关(r=0.240,P=0.000;r=0.163,P=0.007)。峡部宽度和螺钉通道长度,峡部宽度和螺钉通道的头倾角度之间都呈中度负相关(r=-0.333,P=0.000;r=-0.380,P=0.000)。结论:进行枢椎后路峡部螺钉固定安全、可靠,比枢椎后路椎弓根螺钉固定具有更大的适用范围,可以作为椎弓根螺钉的替代选择。  相似文献   

18.
Knowledge of the bony thickness of the acetabular columns is one requisite for safe execution of percutaneous fixation of acetabular fractures. We performed a cadaveric study to determine anatomical dimensions of the columns of acetabulum with reference to percutaneous screw fixation. Twenty-two hemipelves (11 pairs) from 6 male and 5 female cadavers were measured and statistically analysed.In the anterior column, the psoas groove displayed the least vertical thickness of 15.1 mm (range, 12.1-18.2 mm), followed by the obturator canal with 15.9 mm (range, 12.2-20.6 mm). The mean thickness of the posterior column wall of the acetabulum along the screw path displayed 21.3 mm (range, 16.5-30.3 mm). This study provides a clinical map for safe passage of both antegrade and retrograde percutaneous screws. Anatomic data suggests that 7.3 mm cannulated screws can be safely accommodated by the anterior and posterior columns of the acetabulum.  相似文献   

19.
目的 通过骨盆数字化三维重建模型探讨髋臼后柱及股骨头的解剖形态学特征,为术中接骨板塑形及髋臼后柱解剖型接骨板的研发提供依据.方法 111例因单侧髋臼、骨盆损伤行骨盆螺旋CT扫描的成年患者,男72例,女39例;年龄18~80岁,平均45.4岁.依据CT扫描数据建立骨盆数字化三维模型.于模型中测量股骨头直径,髋臼后柱接骨板途经的髋臼后壁、近端、远端三段近似圆弧的曲率半径(R1、R2和R3)和反映三段圆弧相对位置关系的髋臼后壁圆弧展角.结果 股骨头直径平均(47.43±3.74) mm,R1 (47.96±7.80) mm,R2(67.71±13.35) mm,R3 (9.76±0.43) mm,髋臼后壁圆弧展角平均51.38°±6.83°.男女两组股骨头直径及髋臼后壁圆弧展角的差异有统计学意义(t=12.37,P=0.00;t=2.63,P=0.01),而R1、R2、R3两组差异无统计学意义(t=1.05,P=0.30;t=1.36,P=0.18;t=0.72,P=0.47).髋臼后壁圆弧展角与股骨头直径呈正相关(r=0.37,P=0.00),R1、R2和R3与殷骨头直径不相关(r=0.09,P=0.34;r=0.08,P=0.43;r=-0.00,P=0.98).R2总体上随R1增大而增大,髋臼后壁圆弧展角随R1及R2增大而减小,R3变化范围不大.结论 髋臼后柱的解剖形态存在个体差异,其形态与股骨头直径及患者性别不相关,其中髋臼后壁弧度是决定髋臼后柱接骨板形态的主要因素.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号