首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
A biotin/avidin solid-phase enzyme immunoassay for the detection and quantitation of the antibody to hepatitis B surface antigen (anti-HBs) is described. The assay utilizes hepatitis B surface antigen (HBsAg) as a solid-phase 'capture' reagent and a mixture of biotinylated HBsAg and avidin-conjugated horseradish peroxidase as a probe 'detector' reagent. The assay was compared to a commercial radioimmune assay for anti-HBs detection. The two assays were found to measure the same molecules and to correlate well regarding anti-HBs titers.  相似文献   

2.
A direct (antiglobulin) solid-phase enzyme immunoassay for the detection of antibody to hepatitis B core antigen (anti-HBc) is described. The assay utilizes recombinant hepatitis B core antigen as the solid-phase 'capture' reagent and a mixture of monoclonal antibodies specific for human IgG and IgM conjugated to horseradish peroxidase as the 'detector' reagent. The direct assay demonstrated excellent sensitivity and specificity when compared with a commercially available competitive enzyme immunoassay. The direct assay format lends itself to a confirmatory assay for anti-HBc by addition of monoclonal anti-HBc to the reaction mixture. Feasibility of the confirmatory assay for anti-HBc was demonstrated using specimens reactive for anti-HBc as documented by both the direct and competitive assays.  相似文献   

3.
We studied the feasibility of detecting antibody to hepatitis B surface antigen (anti-HBs) by an inhibition assay using the reagents of an enzyme-immunoassay for HBsAg (Hepanostika). Several modifications of the basic assay were investigated. Sensitivity was greatest when the test sample was incubated with a predetermined amount of HBsAg before the usual procedure of HBsAg detection. The presence of anti-HBs in the test sample was shown by a reduction of the solid-phase bound enzyme label. Results were obtained with a dilution series of serum samples containing anti-HBs, the anti-HBs Reference Panel of the American Bureau of Biologics, sera of hepatitis B patients, and sera of two individuals passively immunised with anti-HBs. The enzyme-immunoassay method showed at least the same sensitivity as passive haemagglutination. It was less sensitive than a commercially available radioimmunoassay (Ausab). There are no indications that non-specific reactions occur frequently. This study also revealed that the antigenaemia of acute hepatitis-B patients can be interrupted by a transient seroconversion.  相似文献   

4.
We investigated the degree of lot-to-lot reagent variation for 5 common immunoassay items. We measured the commercial as well as in-house controls for α-fetoprotein (AFP), ferritin, CA19-9, quantitative hepatitis B surface antigen (HBsAg), and hepatitis B surface antibody (anti-HBs) 10 times each by using both the old and the new lot of reagents whenever a reagent lot was changed, over a period of 10 months. The differences in the mean control values, the percent difference (% difference), and the difference to between-run standard deviation ratio (D:SD ratio) between successive lots were calculated. The % difference in mean control values between 2 reagent lots ranged from 0.1 to 17.5% for AFP, 1.0 to 18.6% for ferritin, 0.6 to 14.3% for CA19-9, 0.6 to 16.2% for HBsAg, and 0.1 to 17.7% for anti-HBs except negative controls of HBsAg and anti-HBs. The maximum D:SD ratios between 2 lots were 4.37 for AFP, 4.39 for ferritin, 2.43 for CA19-9, 1.64 for HBsAg, and 4.16 for anti-HBs. Thus, we have experienced extensive variability in lot-to-lot reagent variation for 5 immunoassay items, indicating that reagent lot-to-lot comparability tests should be continuously performed and that laboratories should determine their own acceptance criteria for each item.  相似文献   

5.
A second generation radioimmunoassay (RIA) and enzyme-linked immunoassay (EIA) for the detection and quantitation of the antibody to hepatitis B surface antigen (anti-HBs) was developed which utilizes recombinant DNA-derived HBsAg (rHBsAg) in place of human plasma derived HBsAg. In these sandwich assays, rHBsAg immobilized on a solid phase was used to capture anti-HBs from the specimen and rHBsAg conjugated to horseradish peroxidase or radiolabeled with 125I was used as a detecting reagent. These rHBsAg-based assays were compared to a commercial radioimmunoassay for anti-HBs detection (AUSAB RIA). For a population of 1711 sera and plasma specimens, 99.2% overall agreement was demonstrated between the recombinant RIA and EIA and 98.6% agreement was observed between the recombinant assays and AUSAB-RIA. The recombinant assays demonstrated equivalent sensitivity and detectability to AUSAB RIA. Most discrepant samples were low-level reactive by AUSAB-RIA, generally less than 10 mIU/ml, and likely represent nonspecific reactivity since no other marker for hepatitis B infection was detected in these samples.  相似文献   

6.
Immunoassay detection of hepatitis B surface antigen mutants.   总被引:15,自引:0,他引:15  
The increasing use of hepatitis B vaccination has had an overwhelming positive impact on the prevention of hepatitis B viral infection. Mutations in the hepatitis B surface antigen (HBsAg) gene occur as a result of vaccine escape mutants, anti-hepatitis B surface antigen immunotherapy, or in chronic hepatitis B viral infection. These mutants may present a challenge to immunoassay detection. Evaluation of the immunodetection of various HBsAg mutants has been sporadic, as the occurrence of these mutants is not common, and sufficient volume of serum samples is difficult to obtain. To investigate mutant detection, recombinant antigens were constructed to reflect mutations described in the literature occurring throughout the S gene. A limited number of serum samples exhibiting discordant immunoassay reactivity were also used to construct recombinant antigens. The evaluation of 25 HBsAg mutants across nine commercial assays of differing formats is described. Mutations affecting immunoassay performance were characterized as occurring mainly in loop 2 of the "a" determinant of HBsAg. It was determined that reagent epitope recognition was more significant for mutant detection than assay format.  相似文献   

7.
A method for coupling the hepatitis B surface antigen (HBsAg) to aldehyde-fixed erythrocytes for use in passive hemagglutination assays for anti-HBs is described. This provides a stable and inexpensive reagent having a sensitivity for anti-HBs detection which is only slightly less than solid phase radioimmunoassay.  相似文献   

8.
目的制备抗乙型肝炎表面抗原(hepatitis B surface antigen,HBsAg)的单克隆抗体,检测单克隆抗体与15种变异HBsAg的反应模式。用筛选出的单抗建立快速检测变异HBsAg的ELISA实验方法,并做初步评价。方法用中国乙型肝炎病毒感染者血清中分离的HBsAg免疫BALB/c小鼠,通过杂交瘤细胞融合技术制备抗-HBs单克隆抗体。检测不同单克隆抗体与野生及变异HBsAg的反应性。筛选出两种可以较好识别变异HBsAg的单克隆抗体McAb2和McAb3,建立两种抗体ELISA检测HBsAg的方法。结果制备了14株抗-HBs单抗。经过初筛,有4种可以较好识别包括G145R在内的大多数变异HBsAg。优化了McAb2和McAb3检测HBsAg的条件,检测HBsAg的灵敏度较好,检测变异HBsAg的能力优于2种现行国产HBsAg检测试剂盒。结论用本实验制备的单抗可以很好地识别包括G145R在内的大多数变异HBsAg。  相似文献   

9.
A sensitive method for the detection of hepatitis B surface antigen (HBsAg) is described whereby the separation of specific antibody by affinity chromatography is incorporated into one of the assay reagents. HBsAg, which may be obtained from tissue culture fluids of a human hepatoma cell line, is first reacted with polystyrene beads. Unoccupied spaces on the plastic are next covered with a non-specific protein (e.g. albumin). The plastic is then reacted with either whole antiserum or an IgG fraction of anti-HBs. Care must be taken to cover all of the reacting sites of the first layer of HBsAg with sufficient anti-HBs. This results in a reagent of detecting antigen. No affinity purified antibody was necessary because the reagent, at this stage, contains only specific antibody on the surface. Antigen reacting with this reagent can be detected by the addition of radioactively labeled IgG fraction of anti-HBs, which will complete the 'sandwich'. This assay has been evaluated and found to be as sensitive as those commerically available.  相似文献   

10.
The strategy to eliminate hepatitis B virus (HBV) infection by administrating an HB vaccine is changing worldwide; however, this is not the case in Japan. An important concern about the HBV infection-preventing strategy in Japan may be that the assay methods for the antibody to hepatitis B surface antigen (anti-HBs) are not standardized. The minimum protective anti-HBs titer against HBV infection has been established as 10 mIU/ml by World Health Organization (WHO) -standardized assay methods worldwide, but that is still determined as a "positive" test result by the passive hemagglutination (PHA) method in Japan. We compared anti-HBs measurements in given samples among PHA(Mycell II, Institute of Immunology), chemiluminescent enzyme immunoassay (CLEIA) (Lumipulse, Fujirebio), and chemiluminescent immunoassay (CLIA) (Architect, Abbott), all of which are currently in wide use in Japan. First, anti-HBs measurements in serum from individuals who received a yeast-derived recombinant HB vaccine composed of the major surface protein of either subtype adr or subtype ayw were compared. The results clearly showed that in subtype adr-vaccinees CLIA underestimated the anti-HBs amount compared with CLEIA and PHA, but in ayw-vaccinees, the discordance in the measurements among the three kits was not prominent. Second, anti-HBs measurements in standard or calibration solutions of each assay kit were compared. Surprisingly, CLEIA showed higher measurements in all three kit-associated standard or calibration solutions than CLIA. Thus, the anti-HBs titer of 10 mIU/ml is difficult to introduce in Japan as the minimum protective level against HBV infection. Efforts to standardize anti-HBs assay methods are expected to share international evidence about the HBV infection-preventing strategy.  相似文献   

11.
Two assays for the detection of antibody against hepatitis B surface antigen (anti-HBs) were compared. The first was a direct sandwich radioimmunoassay (RIA) which detects, in principle, antibody against any epitope of hepatitis B surface antigen (HBsAg). The second assay was an inhibition enzyme-linked immunosorbent assay (ELISA). In this assay a fixed amount of HBsAg which can be blocked by anti-HBs is measured in a direct sandwich test. Prevaccination screening sera (n = 191) and follow-up sera obtained from high risk groups (n1 = 85; n2 = 41) during two hepatitis B vaccine studies were compared in RIA and ELISA. In prevaccination sera either HBsAg or anti-HBs were detected by ELISA. Full agreement between the results of RIA and ELISA for anti-HBs was obtained in sera containing more than 10 IU/1 anti-HBs. Both tests showed variable results at low titres. Experiments with monoclonal anti-HBs indicated that ELISA is less sensitive for subtype specific antibodies (anti-d, anti-y), which may explain that there were consistent differences between RIA and ELISA in a minority of cases.  相似文献   

12.
The performance of hepatitis B surface antigen (HBsAg) screening assays is continuously improved to reduce the risk of transfusion-associated hepatitis B. In this study, a semiautomated immune complex transfer chemiluminescence enzyme immunoassay (ICT-CLEIA) for the detection of HBsAg, which is as sensitive as hepatitis B virus (HBV) DNA PCR, was developed; the ICT-CLEIA assay performance was compared with the performance of the Architect HBsAg QT assay and HBV DNA PCR. The specificities in the initial assay and after retesting were 99.50% (1,988/1,998 samples) and 99.95% (1,997/1,998 samples), respectively. The analytical detection limit was determined to be 0.2 mIU/ml using the 2nd International WHO HBsAg standard, and the cutoff value (0.5 mIU/ml) of the ICT-CLEIA assay was 8.0 standard deviations (SD) above the mean of the HBsAg-negative specimens. The ICT-CLEIA assay could detect HBsAg even in the presence of anti-HBs antibodies and demonstrated a 23.6-day-shorter window period using commercially available HBsAg seroconversion panels than the Architect HBsAg QT assay. Furthermore, the monitoring of the viral kinetics by the ICT-CLEIA assay and the HBV DNA PCR produced very similarly shaped curves during both the HBsAg seroconversion and reverse seroconversion periods. Therefore, the ICT-CLEIA assay may be useful not only for an earlier detection of HBV reactivation but also for the monitoring of hepatitis B patients.  相似文献   

13.
Six hundred forty-three children, negative for markers of hepatitis B virus (HBV) infections, were given three X 2-micrograms doses of Merck, Sharp and Dohme (MSD) plasma derived hepatitis B vaccine (H-B-Vax) at monthly intervals. Twelve months after the first dose of vaccine, antibody to hepatitis B surface antigen (anti-HBs) was detected in 89% of children by radioimmunoassay (RIA) and in 83% by enzyme immunoassay (EIA). Seroconversion rates and anti-HBs titres were significantly greater in 1-4-year-olds than in older children (p less than 0.01). Eighteen children with no anti-HBs or other markers of HBV at this time were given 10 micrograms of vaccine and tested one month later. Seventeen developed anti-HBs, 12 at levels consistent with an anamnestic response. Forty-nine HBV-marker-negative children seroconverted for antibody to hepatitis B core antigen (anti-HBc) in the 8-month period before or the 12-month period following vaccination. Forty-six of these children were positive for anti-HBs, and one has been confirmed as a chronic carrier of hepatitis B surface antigen (HBsAg). Three cases of clinical hepatitis B in children have been seen in the community since the vaccination programme began. Two of these were amongst the estimated 5% of children who were not vaccinated. The third was in a vaccinee and occurred 4 1/2 months after the last dose of vaccine.(ABSTRACT TRUNCATED AT 250 WORDS)  相似文献   

14.
目的 制备筛选可识别变异表面抗原(hepatitis B surface antigen,HBsAg)的单克隆抗体(monoclonal antibody, mAb).用筛选出的单克隆抗体建立检测变异HBsAg的ELISA实验方法.方法 用血源HBsAg免疫Balb/c小鼠,通过杂交瘤细胞融合技术制备抗-HBs单克隆抗体.不同单克隆抗体包被酶标反应孔,检测真核细胞表达的野生及变异HBsAg,了解各种单克隆抗体的反应模式 .筛选出可以较好识别变异HBsAg的单克隆抗体Hb1,优化该抗体ELISA检测HBsAg的方法,与 8种HBs Ag检测试剂比较检测变异HBsAg的能力.结果 经过筛选,得到一种可以较好识别包括G145R在内大多数变异HBsAg的单克隆抗体.检测变异HBsAg的能力优于市售HBsAg 诊断试剂.结论 用本实验制备的单克隆抗体可以用于ELISA检测变异HBsAg,减少HBsAg变异株的漏检率.  相似文献   

15.
Antibodies to influenza virus and human immunodeficiency virus are detectable in B cells during the early stages of the immune response, prior to their occurrence in plasma. To investigate similar phenomena in a model of immunization against hepatitis B virus (HBV) infection, medical students in Ghana were screened for HBV markers, HBV surface (HBs) antigen (HBsAg), and HBV core antibodies (anti-HBc). Consenting volunteers, 24 of whom were seronegative (susceptible) and 2 of whom were positive for anti-HBc (prior infection), were vaccinated on day 0, day 40, and 6 months. Two sets of 10 blood samples, sequentially collected at intervals of 2 days following each immunization on days 0 and 40, were processed into B-cell lysates and plasma. Solid-phase HBsAg coated on microtiter plates for enzyme immunoassay or nitrocellulose membranes for dot blot assay was used to detect anti-HBs activity by an indirect antiglobulin assay. A commercially procured sandwich immunoassay was used, along with an enzyme-linked immunosorbent assay and a dot blot assay, for the detection of anti-HBs in B-cell lysates and plasma. Following the first injection of vaccine, a single sample of B-cell lysate collected between 5 and 21 days revealed anti-HBs in 18/21 subjects with no plasma antibodies detectable by sandwich immunoassay. After the booster dose was injected on day 40, a single sample of B-cell lysate collected between 44 and 49 days showed anti-HBs in 16/19 subjects, and this was accompanied by plasma antibodies in 8 subjects. In contrast, between 8 and 13 days, both subjects with prior HBV infection showed anti-HBs in B-cell lysates and plasma. Thus, primary immunization with the HBV vaccine appears to transiently elicit low-affinity anti-HBs in B-cell lysates into plasma.  相似文献   

16.
A fully automated microparticle enzyme immunoassay, IMx AUSAB, was developed for the detection and quantitation of antibody against hepatitis B surface antigen (anti-HBs). The IMx AUSAB assay can complete 24 tests in less than 45 minutes. Anti-HBs concentrations in specimens are calculated automatically by comparison of the specimen rate to values determined from a stored standard curve. IMx AUSAB sensitivity is 2-3 mIU/ml, equivalent in sensitivity to AUSAB RIA or EIA. Specimens from blood donors, diagnostic and hospital patients, hepatitis B vaccinees, and individuals with a variety of infectious and autoimmune diseases tested in parallel by IMx AUSAB and AUSAB RIA or IMx AUSAB and EIA gave overall qualitative agreement of 97.8% (1265/1293) and 99.1% (1281/1293), respectively. The prevalence of anti-HBs ranged from 5.9% in volunteer blood donors to 47.0% of specimens from a sexually transmitted disease clinic. Most discordant specimens (18/34) were low level reactive (less than 10 mIU/ml) by AUSAB RIA, but negative by IMx AUSAB and AUSAB EIA. These specimens were also negative for antibodies to hepatitis B core antigen (anti-HBc). Six discordants were low level reactive by IMx but negative by RIA and EIA. Three of these six specimens were also reactive for anti-HBc suggesting that the IMx AUSAB reactivity resulted from the presence of low level anti-HBs. Quantitative agreement between IMx AUSAB and RIA or IMx and EIA for 106 specimens ranging in anti-HBs concentration from 1 to 30,000 mIU/ml gave linear correlation coefficients of 0.91 and 0.96, respectively. The IMx test was useful for monitoring hepatitis B vaccine response and seroconversion levels after hepatitis B infection.  相似文献   

17.
Following Blumberg's discovery of hepatitis B surface antigen (HBsAg), many attempts have been made to develop several in vitro diagnostic techniques for the detection of this antigen and its homologous antibody. The two-dimensional micro-Ouchterlony immunodiffusion has been the first technique used, rapidly replaced by procedures of increasing sensitivity characterized as second-generation and the currently available third-phase tests which include radioimmunoassay (RIA), reverse passive haemagglutination (RPHA), reverse passive latex agglutination (RPLA) and enzyme immunoassay (EIA). Among these, RIA appears to be the most sensitive and specific, whereas EIA, RPHA and RPLA have the advantage of long shelf-life of stable reagents, no need for sophisticated and expensive equipment and no hazard associated with the handling of radioactive isotopes. Moreover, the sensitivity of EIA should increase by objective reading with a colorimeter.The most sensitive method for the detection of surface antibody (anti-HBs) is again RIA, whereas passive haemagglutination (PHA) had the advantage of providing titres. Finally EIA, based on inhibition of a known amount of HBsAg, has at least the same sensitivity as PHA, but has the advantage that reagents are more stable and that it permits screening for both HBsAg and anti-HBs with the same reagents at the same time. The application of these highly sensitive techniques for the detection of HBsAg and anti-HBs has resulted in a consistent reduction in the incidence of post-transfusion hepatitis type B and in a better understanding of the aetiology, epidemiology and natural history of this infection.  相似文献   

18.
Antibodies to polymerized human albumin (poly-HSA) could not be detected by using sensitive methods (enzyme-linked immunosorbent assay and radioimmunoprecipitation) in sera from chronic carriers of hepatitis B surface antigen (HBsAg) or in serial bleedings from one chimpanzee infected with type A hepatitis virus and one infected with non-A, non-B hepatitis virus. By a solid-phase radioimmunoassay, receptor sites for poly-HSA could be detected on HBsAg particles from sera containing either hepatitis B "e" antigen (HBeAg) or anti-HBe. Blocking experiments showed that monomeric HSA did not bind to this receptor. In general, the HBsAg particles from sera with HBeAg had more poly-HSA receptor sites or relatively more particles carrying this receptor compared with HBsAg from sera with anti-HBe. Microtiter plates coated with poly-HSA bound HBsAg from sera containing HBeAg with greater efficiency than did anti-HBs coupled to a solid phase (Ausria II beads), whereas with sera positive for anti-HBe, the two assays were equally sensitive. Decreased ability of HBsAg to bind to poly-HSA was seen in some sera which had been stored for a few years at 4 degrees C, whereas the binding to anti-HBs was unaffected. It is possible that polymers of albumin on the surface of hepatocytes could function as receptors for hepatitis B virus.  相似文献   

19.
We report a patient with antibody to hepatitis B surface antigen (anti-HBs) but no antibodies to other hepatitis B virus components, who developed acute symptomatic type B hepatitis. The possible explanations for this unusual serological pattern are 1) the antibody-positive status, which developed against only a subdeterminant of hepatitis B surface antigen (HBsAg), arose naturally or as the result of cross-reaction with a variety of antigens; and 2) seroconversion to anti-HBs occurred in response to surface antigen of a mutant strain of hepatitis B virus (HBV). This anti-HBs positivity, in the absence of antibody to hepatitis B core antigen, does not provide natural immunization against HBV infection, and so is not protective. Individuals who are positive to anti-HBs antibody alone which is not elicited by HBV vaccine, should be vaccinated against possible HBV infection.  相似文献   

20.
An enzyme-linked immunosorbent assay for detection of specific immunoglobulin M (IgM) antibodies against the core antigen of the hepatitis B virus (anti-HBc IgM) is described. The interference of IgM rheumatoid factor was evaluated quantitatively. In the anti-HBc IgM test, the rheumatoid factor gave false-positive results when the concentration exceeded 20 IU/ml. The rheumatoid-positive sera were disclosed by a control and retested for anti-HBc IgM after absorption of rheumatoid factor with latex particles aggregated with human IgG. In five of seven selected patients with acute hepatitis B followed to biochemical and clinical recovery, anti-HBc IgM was present transiently until antibodies against hepatitis B surface antigen (anti-HBs) appeared. Two patients had persistent anti-HBc IgM during the follow-up period. Four patients with hepatitis B surface antigenemia and progression to chronic liver disease did not clear their anti-HBc IgM in the period of observation (11 to 24 months). Anti-HBc IgM could not be demonstrated in 223 of 225 Danish blood donors. The two donors found positive for anti-HBc IgM also had anti-HBs. Twenty patients with acute A or non-A non-B hepatitis were negative for anti-HBc IgM. The enzyme-linked immunosorbent assay for anti-HBc IgM described here has a high specificity and sensitivity. The diagnostic relevance needs further evaluation, including quantitation of anti-HBc IgM, but the results presented indicate that anti-HBc IgM may be helpful in differentiating between prior and recent or ongoing hepatitis B infection.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号