共查询到20条相似文献,搜索用时 15 毫秒
1.
A Toxoplasma gondii immunoglobulin G (IgG) avidity enzyme-linked immunosorbent assay (ELISA) was developed that combines the accuracy of assays based on end point titers and the relative ease of assays based on optical density values. Like published procedures, the new assay's avidity index (AI) was based on differential T. gondii-specific IgG reactivity in serum-treated wells washed with urea buffer versus that in wells washed with control buffer; unlike previous assays, however, the IgG reactivity was measured quantitatively using a standard curve. The assay was evaluated using 24 IgG-positive and IgM-positive sera collected within 5 months of the onset of symptoms (recent-infection group) and 25 IgG-positive and IgM-negative sera (past-infection group). All sera in the recent-infection group exhibited AI values of <0.18, whereas all sera in the past-infection group exhibited AI values of >0.27. The AI values of the recent-infection group showed significant correlation with the number of days after the onset of symptoms. A subset of 16 sera (8 recent and 8 past) was tested using a commercially available T. gondii IgG avidity ELISA based on end point titration; the results of the two assays showed highly significant correlation (R2 = 0.9125). In addition, we confirmed and extended the findings of other investigators, showing that AI values calculated using optical density values, but not AI values calculated using quantitative IgG values, varied significantly depending on the serum dilution used. This new assay should facilitate the accurate measurement of T. gondii IgG avidity in a reference laboratory setting. 相似文献
2.
C. L. Vermont H. H. van Dijken C. J. P. van Limpt R. de Groot L. van Alphen G. P. J. M. van den Dobbelsteen 《Infection and immunity》2002,70(2):584-590
The avidity maturation and immunoglobulin G (IgG) isotype distribution of antibodies after vaccination with a meningococcal B outer membrane vesicle (OMV) vaccine were evaluated as indicators of protective immunity. Pre- and postvaccination sera from 134 healthy toddlers (ages, 2 to 3 years) immunized with a monovalent meningococcal B OMV (serosubtype P1.7-2,4) vaccine adsorbed with AlPO(4) or Al(OH)(3) were analyzed by enzyme-linked immunosorbent assay (ELISA) methods. The children were vaccinated three times with intervals of 3 to 6 weeks between vaccinations or twice with an interval of 6 to 10 weeks between vaccinations. A booster was given after 20 to 40 weeks. The avidity index (AI) of antibodies increased significantly during the primary series of vaccinations and after the booster was given. No differences in AIs were found when the results obtained with the two vaccination schedules or with the two adjuvants were compared. After vaccination, IgG1 was the predominant IgG isotype, followed by IgG3. No IgG2 or IgG4 was detected. There was a strong correlation between serum bactericidal activity (SBA) and ELISA titers (r = 0.85 [P < 0.0001] for total IgG, r = 0.83 for IgG1 [P < 0.0001], r = 0.82 for IgG3 [P < 0.0001], and r = 0.84 [P < 0.0001] for the avidity titer). When two subgroups with similar anti-OMV IgG levels were compared before and after the booster vaccination, the higher AI after the booster vaccination was associated with significantly increased SBA. We concluded that avidity maturation occurs after vaccination with a monovalent meningococcal B OMV vaccine, especially after boosting, as indicated by a significant increase in the AI. Vaccination with the monovalent OMV vaccine induced mainly IgG1 and IgG3 isotypes, which are considered to be most important for protection against meningococcal disease. An increase in the AI of antibodies is associated with increased SBA, independent of the level of specific IgG and the IgG isotype distribution. Measuring the AI and IgG isotype distribution of antibodies after vaccination can be a supplementary method for predicting protective immunity for evaluation in future phase III trials with meningococcal serogroup B vaccines. 相似文献
3.
Immunoglobulin G Avidity in Diagnosis of
Toxoplasmic Lymphadenopathy and Ocular Toxoplasmosis 下载免费PDF全文
Malgorzata Paul 《Clinical and Vaccine Immunology : CVI》1999,6(4):514-518
Traditional serological techniques have some limitations in evaluating the duration of Toxoplasma gondii infection in pregnant women, patients with lymphadenopathy, and older children suspected of having congenital toxoplasmosis. In these three groups of patients, two variants of T. gondii immunoglobulin G (IgG) avidity tests were used: an EIA Kit (Labsystems) and a noncommercial enzyme-linked immunosorbent assay specially elaborated in the laboratory. The avidity of specific IgG in sera from 23 patients with a known recently acquired infection (mainly pregnant women) was low (less than 30%), whereas that in sera from 19 patients with toxoplasmic lymphadenopathy of 3 weeks to 6 months in duration (mean, 8.3 weeks) covered a large range (between 0.2 and 57.8%; mean, 25.7%); high avidity results were observed for 10 of 19 patients (52.6%). The large range of IgG avidity in patients with toxoplasmic lymphadenopathy suggests various durations of infection in these patients, with a tendency for a chronic phase of toxoplasmosis. According to the avidity marker, five patients with lymphadenopathy for less than 3 months did not have a recent Toxoplasma infection. In 6 of 19 patients with lymphadenopathy (31.6%), low IgG avidity values persisted until 5 months after the first serological examination. In all four patients with a documented chronic course of Toxoplasma infection (6 months to 8 years after the first positive serology), high IgG avidity values were observed. Among sera from 10 children and young immunocompetent adults suspected of having ocular reactivation of congenital toxoplasmosis, all had high IgG avidity values (over 40%), suggesting congenitally acquired ocular infection rather than noncongenital infection. In conclusion, the avidity of IgG is a valuable marker of recent toxoplasmosis in pregnant women, suggests the duration of invasion in patients with lymphadenopathy, and may be helpful for differentiation between reactivation of congenital infection and recently acquired ocular toxoplasmosis in immunocompetent patients. A low IgG avidity does not always identify a recent case of toxoplasmosis, but a high IgG avidity can exclude primary infections of less than 5 months’ duration. 相似文献
4.
A New Method with General Diagnostic Utility for the Calculation of Immunoglobulin G Avidity 总被引:2,自引:2,他引:0 下载免费PDF全文
Maria H. Korhonen John Brunstein Heikki Haario Alexei Katnikov Roberto Rescaldani Klaus Hedman 《Clinical and Vaccine Immunology : CVI》1999,6(5):725-728
The reference method for immunoglobulin G (IgG) avidity determination includes reagent-consuming serum titration. Aiming at better IgG avidity diagnostics, we applied a logistic model for the reproduction of antibody titration curves. This method was tested with well-characterized serum panels for cytomegalovirus, Epstein-Barr virus, rubella virus, parvovirus B19, and Toxoplasma gondii. This approach for IgG avidity calculation is generally applicable and attains the diagnostic performance of the reference method while being less laborious and twice as cost-effective. 相似文献
5.
Evaluation of Six Immunoassays for Detection of Dengue Virus-Specific Immunoglobulin M and G Antibodies 下载免费PDF全文
Jan Groen Penelopie Koraka Jans Velzing Cedrick Copra Albert D. M. E. Osterhaus 《Clinical and Vaccine Immunology : CVI》2000,7(6):867-871
The performance of six commercially available immunoassay systems for the detection of dengue virus-specific immunoglobulin M (IgM) and IgG antibodies in serum was evaluated. These included two IgM and IgG enzyme immunoassays (EIA) from MRL Laboratories and PanBio, a rapid immunochromatographic test (RIT) from PanBio, immunofluorescence assays (IFA) from Progen, a dot blot assay from Genelabs, and a dipstick EIA from Integrated Diagnostics (INDX). For this study a panel of 132 serum samples, including 90 serum samples from patients with suspected dengue virus infection and 42 serum samples from patients with other viral infections, was used. In addition, serial serum samples from two monkeys experimentally immunized and challenged with dengue virus type 2 were used. Results were considered conclusive when concordant results were obtained with four of the six antibody-specific assays. Based on this definition, the calculated overall agreement for the human serum samples for the respective IgM immunoassays was 97% (128 of 132), with 34% (45 of 132) positive serum samples, 63% (83 of 132) negative samples, and 3% of samples (4 of 132) showing discordant results. The calculated overall agreement for the IgG assays was 94% (124 of 132), with 49% (65 of 132) positive, 45% (59 of 132) negative, and 6% (8 of 132) discordant results, respectively. The sensitivities of the dengue virus-specific assays evaluated varied between 71 and 100% for IgM and between 52 and 100% for IgG, with specificities of 86 to 96% and 81 to 100%, respectively. The relative sensitivities of the respective IgM assays measured with the monkey serum samples were comparable with those obtained with 12 serial serum samples from humans. Overall performance, based on the sum of the agreement, sensitivity, specificity, and Kappa statistics of the IgM and IgG immunoassays, showed that the antibody detection systems from INDX and Genelabs and the MRL and PanBio EIA are useful and reliable assays for dengue virus serodiagnosis. 相似文献
6.
Reliability of Immunoglobulin G Antitoxoplasma Avidity Test and Effects of Treatment on Avidity Indexes of Infants and Pregnant Women 下载免费PDF全文
Pierre Flori Laetitia Tardy Hugues Patural Bahrie Bellete Marie-Noëlle Varlet Jamal Hafid Hlne Raberin Roger Tran Manh Sung 《Clinical and Vaccine Immunology : CVI》2004,11(4):669-674
The immunoglobulin G antitoxoplasma avidity test (Vidas; BioMérieux) is an immunoenzymatic test useful for excluding acute infection after the onset of pregnancy. The avidity index (AI) is the ratio of the signal in a test sample washed with urea, which disrupts low-avidity complexes, to that washed without urea. An AI of >0.3 is taken to mean that infection had occurred more than 4 months ago. The increase of the AI with time and the influence of the different treatments given to pregnant women and their newborns were evaluated. A total of 59 pregnant women (271 sera) and their 60 neonates (199 sera) were tested from 1998 to 2002. There were five groups of women based on the type and duration of treatment given. Thirteen pregnant women (group 1) did not receive any treatment, 15 (group 2), 11 (group 3), and 17 (group 4) women received treatment with spiramycin (9 MIU/day) for 0.5 to 2, 2.5 to 5, and 5.5 to 8 months, respectively, and the last 3 women (group 5) received tritherapy (pyrimethamine-sulfonamide and spiramycin alternatively) for 1.5 to 2.5 months. All of the maternal sera collected in the first 6 months had an AI of <0.30, with a mean of 0.07 (range, 0.01 to 0.21). The increase was slow (0.02/month), and there was no significant difference when comparisons were made between the treatment groups. Neonates with proven maternofetal transmission had an increasing AI, unlike those without transmission. However, long-term therapy with pyrimethamine-sulfonamide, as opposed to treatment with spiramycin alone, was found to slow down the progression of the AI. An AI of >0.2 is sufficient to exclude acute infection in pregnant women. In neonates, it is not of major use to diagnose congenital infection; however, it could be a good indicator of compliance and efficacy of treatment of infected infants. 相似文献
7.
Clinical Evaluation of a Chemiluminescence Immunoassay for Determination of Immunoglobulin G Avidity to Human Cytomegalovirus 总被引:3,自引:0,他引:3 下载免费PDF全文
Maria Grazia Revello Giovanna Gorini Giuseppe Gerna 《Clinical and Vaccine Immunology : CVI》2004,11(4):801-805
Clinical evaluation of a novel fully automated chemiluminescence immunoassay for determination of immunoglobulin G avidity to human cytomegalovirus (HCMV) showed 92.8% sensitivity and 84.7% specificity in detecting a recent (≤90 days) primary HCMV infection. The assay appears useful for accurately diagnosing recent primary HCMV infections. 相似文献
8.
Validation of an In-House Assay for Cytomegalovirus Immunoglobulin G (CMV IgG) Avidity and Relationship of Avidity to CMV IgM Levels 下载免费PDF全文
Measurement of cytomegalovirus (CMV)-specific immunoglobulin G (IgG) avidity has proven to be a powerful tool for distinguishing primary from nonprimary CMV infection. An in-house enzyme-linked immunosorbent assay (ELISA) for measuring CMV IgG avidity was validated using 84 sera from pregnant women who had recently seroconverted following primary CMV infection and 74 sera from individuals with past CMV infection (IgG-positive and IgM-negative profile). Of the 84 sera from pregnant women, 73 sera were collected within 120 days of the last IgG-negative sample, and 72 of these 73 sera (99%) exhibited an avidity index (AI) of <50%. In contrast, 71 of 74 (96%) sera from individuals with past CMV infection exhibited CMV AI values of >60%. Thus, low avidity in the in-house ELISA was defined as an AI of 50%, whereas high avidity was defined as an AI of 60%. In additional studies, the relationship between CMV IgG avidity and CMV IgM levels was examined using 64 CMV IgG-positive sera (time since seroconversion unknown) exhibiting equivocal or positive results in a CMV IgM capture ELISA (Diamedix). Of these 64 sera, 29 exhibited IgM index values of 3.0, and 27 of these 29 (93%) exhibited low IgG avidity. A similar trend was observed when a subset of these 64 sera (n = 48) was tested in another CMV IgM capture ELISA (Trinity); of 18 sera with IgM index values of 3.0, 17 (94%) exhibited low IgG avidity. These findings demonstrate the validity of an in-house ELISA for CMV IgG avidity and further show that strong reactivity of CMV IgG-positive sera in either of two CMV IgM capture assays is a reliable indicator of low CMV IgG avidity, and thus, recent CMV infection. 相似文献
9.
Multicenter Evaluation of a Rapid and Convenient Method for Determination of Cytomegalovirus Immunoglobulin G Avidity 下载免费PDF全文
Monique Baccard-Longere Francois Freymuth Denis Cointe Jean Marie Seigneurin Liliane Grangeot-Keros 《Clinical and Vaccine Immunology : CVI》2001,8(2):429-431
An easy, rapid, and reproducible test to distinguish residual cytomegalovirus (CMV) immunoglobulin M (IgM) antibodies from antibodies produced in primary infection could be useful, especially for pregnant women. The CMV avidity of IgG antibodies with the VIDAS automated enzyme-linked fluorescent assay and 6 M urea was evaluated in a multicenter study to differentiate between primary CMV infections and past infections or reactivations. A total of 416 serum specimens were tested: 159 specimens were from follow-up of primary infections, and 257 were from past infections. All of the specimens from primary infections collected within 4 months (17 weeks) after the onset of the infection had an avidity index lower than 0.8. An avidity index higher than 0.8 excludes a recent primary infection of less than 4 months. However, an avidity index higher than 0.8 cannot confirm all past infections, since 48 specimens (18%) from past infections had an avidity index lower than 0.8 (between 0.5 and 0.8). The exclusion capacity could be improved (96.9%) by using a cutoff of 0.7, but this index would decrease the specificity of the technique, since the avidity index was found to be between 0.7 and 0.8 in two patients with recent primary infection. All specimens from primary infections obtained more than 4 months after the onset of infection had an avidity index more than 0.2. In this study, an avidity index less than 0.2 confirms the presence of a recent primary infection of less than 4 months. The VIDAS CMV IgG avidity test is a rapid, reproducible test with very good performance. 相似文献
10.
Lack of Utility of Specific Immunoglobulin G Antibody Avidity for Serodiagnosis of Reactivated Toxoplasmosis in Immunocompromised Patients 下载免费PDF全文
Bndicte Mechain Yves Jean-Franois Garin Florence Robert-Gangneux Jean Dupouy-Camet Francis Derouin 《Clinical and Vaccine Immunology : CVI》2000,7(4):703-705
The avidities of Toxoplasma-specific immunoglobulin G serum antibodies were measured in immunocompromised patients presenting with cerebral or extracerebral toxoplasmosis and/or serological reactivation. Since avidity remained high and stable in 39 of 40 patients with toxoplasmosis and 27 of 28 patients with serological reactivation, we conclude that this test cannot help diagnose toxoplasmosis in these patients. 相似文献
11.
Identification of Primary and Secondary Measles Vaccine Failures by Measurement of Immunoglobulin G Avidity in Measles Cases during the 1997 São Paulo Epidemic 下载免费PDF全文
Cludio S. Pannuti Ricardo Jos Morello Jos Cssio de Moraes Suely Pires Curti Ana Maria S. Afonso Maria Cludia Corrêa Camargo Vanda A. U. F. de Souza 《Clinical and Vaccine Immunology : CVI》2004,11(1):119-122
Despite almost universal use of measles vaccines in recent decades, epidemics of the disease continue to occur. Understanding the role of primary vaccine failure (failure to seroconvert after vaccination) and secondary vaccine failures (waning immunity after seroconversion) in measles epidemics is important for the evaluation of measles control programs in developing countries. After a measles epidemic in São Paulo, Brazil, 159 cases previously confirmed by detection of specific immunoglobulin M (IgM) antibodies were tested for IgG avidity, and a secondary immune response, defined by an IgG avidity index of at least 30%, was established in 30 of 159 (18.9%) patients. Among the 159 patients, 107 (67.3%) had not been vaccinated and 52 (32.7%) had received one or more doses of measles vaccine. Of the 107 unvaccinated patients, 104 (97.2%) showed a primary immune response, defined as an IgG avidity index of less than 30%. Among the 52 patients with documented vaccination, 25 (48.1%) showed a primary immune response and 27 (51.9%) showed a secondary immune response, thereby constituting a secondary vaccine failure. Primary vaccine failure was observed in 13 of 13 patients vaccinated prior to 1 year of age and in 43.5 and 12.5%, respectively, of patients receiving one or two doses after their first birthdays. These results provide evidence that measurement of IgG avidity can be used to distinguish between primary and secondary vaccine failures in vaccinated patients with measles; the method can also be a useful tool for the evaluation of measles control programs. 相似文献
12.
Sara Mercader Philip Garcia William J. Bellini 《Clinical and Vaccine Immunology : CVI》2012,19(11):1810-1817
In regions where endemic measles virus has been eliminated, diagnostic assays are needed to assist in correctly classifying measles cases irrespective of vaccination status. A measles IgG avidity assay was configured using a commercially available measles-specific IgG enzyme immunoassay by modifying the protocol to include three 5-min washes with diethylamine (60 mM; pH 10.25) following serum incubation; serum was serially diluted, and the results were expressed as the end titer avidity index. Receiver operating characteristic analysis was used for evaluation and validation and to establish low (≤30%) and high (≥70%) end titer avidity thresholds. Analysis of 319 serum specimens expected to contain either high- or low-avidity antibodies according to clinical and epidemiological data indicated that the assay is highly accurate, with an area under the curve of 0.998 (95% confidence interval [CI], 0.978 to 1.000), sensitivity of 91.9% (95% CI, 83.2% to 97.0%), and specificity of 98.4% (95% CI, 91.6% to 100%). The assay is rapid (<2 h) and precise (standard deviation [SD], 4% to 7%). In 18 samples from an elimination setting outbreak, the assay identified 2 acute measles cases with low-avidity results; both were IgM-positive samples. Additionally, 11 patients (15 samples) with modified measles who were found to have high-avidity IgG results were classified as secondary vaccine failures; one sample with an intermediate-avidity result was not interpretable. In elimination settings, measles IgG avidity assays can complement existing diagnostic tools in confirming unvaccinated acute cases and, in conjunction with adequate clinical and epidemiologic investigation, aid in the classification of vaccine failure cases. 相似文献
13.
Molecular Markers in Acute and Chronic Phases of Human Toxoplasmosis: Determination of Immunoglobulin G Avidity by Western Blotting 下载免费PDF全文
P. T. Marcolino D. A. O. Silva P. G. Leser M. E. Camargo J. R. Mineo 《Clinical and Vaccine Immunology : CVI》2000,7(3):384-389
We characterized antigenic markers recognized by human serum samples from patients presenting with acute and chronic toxoplasmosis by the determination of immunoglobulin G (IgG) antibody avidity by a Western blot modified technique (avidity immunoblotting) that includes the dissociation of the antigen-antibody interaction with 6 or 8 M urea solutions. Human serum samples from 20 patients presenting with recent infection and from 20 patients with chronic infection were analyzed. It was observed that bands p16, p32, p38, p40, p43, p54, p60, p66, and p97 were more frequently recognized by low-avidity IgG in recent infection and by high-avidity IgG in chronic toxoplasmosis. From these antigenic bands, p38 can be characterized as an optimal antigenic marker of low avidity for recent forms of toxoplasmosis due to a significant decrease of their frequencies (from 80 to 0%) after treatment with 6 M urea solutions. The p30 antigen was not considered a good marker to distinguish acute from chronic infection since corresponding IgG antibodies were determined to have high avidity in both phases of the infection. Thus, the avidity immunoblotting assay proved to be a useful tool for determining antigenic markers of recent and chronic phases of Toxoplasma gondii infection. 相似文献
14.
Increased Immunoglobulin G Anti-Paracoccidioides brasiliensis Serum Antibody Avidity as a Predictor of Favorable Posttherapeutic Evolution in Paracoccidioidomycosis 下载免费PDF全文
Márcia Yoshida Maria Carmen Arroyo Sanchez Maria Aparecida Shikanai-Yasuda 《Clinical and Vaccine Immunology : CVI》2009,16(11):1583-1586
Paracoccidioidomycosis is endemic in Latin America, and ca. 80% of all cases occur in Brazil. Little is known about antibody avidity or the evolution of such avidity in the posttherapeutic period for the different clinical presentations of the disease. In the present study, we evaluated 53 patients with paracoccidioidomycosis and calculated the avidity index. Medium- and high-avidity antibodies were found in 79.5% of patients with chronic presentation (n = 39). Among patients with the acute form (n = 14), 57.1% of the antibodies presented low avidity. In the posttherapeutic period, there was a significant increase in antibody avidity in patients presenting with the chronic multifocal form. In our preliminary study, which needs to be confirmed using a larger number of samples, the optimized method for studying antibody avidity detected differences among the clinical presentations of the mycosis and indicated the value of the avidity index as a marker of posttherapeutic evolution of patients with a multifocal chronic form of the disease.Paracoccidioidomycosis is an important public health problem and one of the leading causes of occupational disease in Brazil (2). The disease can be classified according to the International Colloquium on Paracoccidioidomycosis (5) as an infection, acute form, chronic multifocal form, chronic unifocal form, and sequelae. The study of antibody avidity has been widely used in the diagnosis of infectious diseases, especially to differentiate between acute and chronic infections (6). In paracoccidioidomycosis, little is known about antibody avidity or the evolution of such avidity in the different clinical forms of the disease. The objective of the present study was to evaluate a method for the study of the avidity of immunoglobulin G (IgG) anti-Paracoccidioides brasiliensis antibodies in serum and to determine the value of the avidity evolution in the posttherapeutic period. To the best of our knowledge, this is the first time that such avidity has been investigated in the different clinical presentations of paracoccidioidomycosis. 相似文献
15.
Detection of Rubella Virus-Specific Immunoglobulin G in Saliva by an Amplification-Based Enzyme-Linked Immunosorbent Assay Using Monoclonal Antibody to Fluorescein Isothiocyanate 总被引:2,自引:0,他引:2 下载免费PDF全文
A. J. Vyse D. W. G. Brown B. J. Cohen R. Samuel D. J. Nokes 《Journal of clinical microbiology》1999,37(2):391-395
An immunoglobulin G (IgG)–capture enzyme-linked immunosorbent assay (ELISA) for rubella virus is described. The assay uses a fluorescein isothiocyanate (FITC)–anti-FITC amplification system. The detection limit of the ELISA was approximately 7 IU of rubella virus-specific IgG per ml of serum sample. For saliva samples the performances of the capture ELISA and previously described radioimmunoassay were assessed, and the results of those two assays were compared to the rubella virus-specific IgG result obtained by a commercial ELISA (Behring Enzygnost) with a panel of paired serum and saliva samples. This comparison showed that the capture ELISA with saliva was more sensitive than the radioimmunoassay and that the results correlated better with the serum IgG result than the results of the radioimmunoassay did, with an overall sensitivity of 82% and a rank correlation of 0.68, whereas the sensitivity and rank correlation for the radioimmunoassay were 74% and 0.45, respectively. For subjects of 10 years of age or younger, the ELISA with saliva had a sensitivity of 94% and a specificity of 100% compared to the results of the ELISA (Behring Enzygnost) for rubella virus-specific IgG with corresponding serum samples. The sensitivity was much lower for subjects ages 17 years or older. The assay may have wider epidemiological use with saliva specimens, particularly those from children. 相似文献
16.
Harry E. Prince 《Clinical Microbiology Newsletter》2019,41(24):213-218
Cytomegalovirus (CMV) IgG avidity, defined as the strength with which IgG binds to an antigen, matures gradually following primary infection. Low avidity indicates recent infection (within the prior 3 months), whereas high avidity indicates infection >6 months earlier. In adults, IgG avidity testing is better than CMV IgM testing for identifying primary infection, since IgM persists for many months in some individuals. The key clinical application of CMV IgG avidity testing is to identify primary CMV infection during pregnancy, which is associated with increased risk for intrauterine transmission. A related application is diagnosis of primary CMV infection in children less than 1 year old. In transplantation, avidity testing helps identify the cellular source of CMV IgG in seroconverting solid organ recipients; in seropositive bone marrow recipients, avidity results serve as an indicator of successful engraftment. An unrealized application is assessment of CMV IgM+ IgG+ organ or blood donors; many are IgM+ due to IgM persistence and may thus still qualify as donors. This article provides a review of CMV IgG avidity methodology, as well as clinical applications. 相似文献
17.
Changes in Avidity and Level of Immunoglobulin G Antibodies to Mycobacterium tuberculosis in Sera of Patients Undergoing Treatment for Pulmonary Tuberculosis 下载免费PDF全文
Lenka M. Pereira Arias-Bouda Sjoukje Kuijper Anouk Van Der Werf Lan N. Nguyen Henk M. Jansen Arend H. J. Kolk 《Clinical and Vaccine Immunology : CVI》2003,10(4):702-709
Much is known about specific antibodies and their titers in patients with tuberculosis. However, little is known about the avidity of these antibodies or whether changes in avidity occur during the progression of the disease or during treatment. The aims of this study were to determine the avidity of antibodies to Mycobacterium tuberculosis in patients with pulmonary tuberculosis, to explore the value of avidity determination for the diagnosis of tuberculosis, and to study changes in levels of antibodies and their avidity during treatment. Antibody avidity was measured by an enzyme-linked immunosorbent assay with thiocyanate elution. Avidity indices and serum levels of immunoglobulin G to M. tuberculosis were determined for 22 patients with pulmonary tuberculosis before and during treatment and for 24 patients with other pulmonary diseases. Antibody levels and avidity were both significantly higher in untreated tuberculosis patients than in the controls. Avidity determination had more diagnostic potential than determination of the antibody levels. Tuberculosis patients with a long duration of symptoms had higher antibody avidity than those with a recent onset of symptoms, indicating affinity maturation of specific antibodies during active disease. In the early phase of treatment, a decrease in antibody avidity was observed for 73% of all tuberculosis patients, accompanied by an initial increase in antibody levels in 36% of these patients. These phenomena could be explained by an intense stimulation of the humoral response by antigens released from killed bacteria, reflecting early bactericidal activity of antituberculous drugs leading to the production of low-affinity antibodies against these released antigens. 相似文献
18.
Anticytomegalovirus (Anti-CMV) Immunoglobulin G Avidity in Identification of Pregnant Women at Risk of Transmitting Congenital CMV Infection 总被引:3,自引:2,他引:1 下载免费PDF全文
Tiziana Lazzarotto Patrizia Spezzacatena Stefania Varani Liliana Gabrielli Paola Pradelli Brunella Guerra Maria Paola Landini 《Clinical and Vaccine Immunology : CVI》1999,6(1):127-129
In this work, we show that the determination of the anticytomegalovirus antibody avidity carried out before week 18 of gestation is a helpful tool to identify women for enrollment in prenatal diagnosis. This procedure can identify all pregnant women who will give birth to an infected newborn. 相似文献
19.
Clinical and Epidemiological Relevance of Quantitating Hepatitis E Virus-Specific Immunoglobulin M 下载免费PDF全文
Jitvimol Seriwatana Mrigendra P. Shrestha Robert M. Scott Sergei A. Tsarev David W. Vaughn Khin Saw Aye Myint Bruce L. Innis 《Clinical and Vaccine Immunology : CVI》2002,9(5):1072-1078
Diagnosis of acute hepatitis E by detection of hepatitis E virus (HEV)-specific immunoglobulin M (IgM) is an established procedure. We investigated whether quantitation of HEV IgM and its ratio to HEV total Ig furnished more information than conventional IgM tests that are interpreted as positive or negative. A previously described indirect immunoassay for total Ig against a baculovirus-expressed HEV capsid protein was modified to quantitate HEV-specific IgM in Walter Reed (WR) antibody units by using a reference antiserum and the four-parameter logistic model. A receiver-operating characteristics curve derived from 197 true-positive specimens and 449 true-negative specimens identified 30 WR units/ml as an optimum cut point. The median HEV IgM level in 36 patients with acute hepatitis E fell from 3,000 to 100 WR units/ml over 6 months, suggesting that 100 WR units/ml would be a more appropriate cut point for distinguishing recent from remote IgM responses. Among three hepatitis E case series, determination of the HEV IgM-to-total-Ig ratio in acute-phase serum revealed that most patients had high ratios consistent with primary infections whereas a few had low ratios, suggesting that they had sustained reinfections that elicited anamnestic antibody responses. The diagnostic utility of the new IgM test was similar to that of a commercially available test that uses different HEV antigens. In conclusion, we found that HEV IgM can be detected specifically in >95% of acute hepatitis E cases defined by detection of the virus genome in serum and that quantitation of HEV IgM and its ratio to total Ig provides insight into infection timing and prior immunity. 相似文献
20.
In this study we compared the performances of three commercially available Epstein-Barr virus (EBV) immunoglobulin M (IgM) assays on highly automated immunoassay platforms: BioPlex 2200 (Bio-Rad Laboratories), Immulite 2000 (Siemens Healthcare Diagnostics), and Liaison (DiaSorin). As a confirmatory method, immunoblotting was performed. The specificity of the three EBV IgM assays was evaluated by testing 293 selected sera from patients with various infectious and noninfectious diseases. After the exclusion of 30 samples, the specificities were 96.2% for Liaison, 98.1% for Immulite, and 97.0% for BioPlex. For evaluation of the sensitivity, samples from 70 consecutive patients with a positive heterophile antibody test were examined, irrespective of clinical or biological findings. After the exclusion of six samples, the sensitivities were 89.1% for Liaison, 84.4% for Immulite, and 89.1% for BioPlex. Finally, in a prospective study performed with 500 samples obtained from consecutive patients and sent in by general practitioners, we also determined Epstein-Barr nuclear antigen IgG and viral capsid antigen IgG in a two-phase approach. Concordance of the EBV serologic status was 96.2% between Liaison and Immulite, 96.4% between Immulite and BioPlex, and 97.8% between BioPlex and Liaison. The three EBV IgM immunoassays that we evaluated have acceptable and comparable performances.Epstein-Barr virus (EBV) is the causative agent of infectious mononucleosis, a clinical syndrome characterized by especially fever, pharyngitis, and adenopathy. However, many other pathogens, such as cytomegalovirus (CMV), human herpesvirus 6, Toxoplasma gondii, human immunodeficiency virus, parvovirus B19, and herpes simplex virus, can cause mononucleosislike illnesses (6, 12). In primary care, the diagnostic approach to infectious mononucleosis frequently involves the determination of EBV-specific IgM antibodies. The ideal EBV-specific IgM assay should not only be sensitive and specific; in the modern laboratory automation, throughput, speed, accessibility, standardization, ease of use, and flexibility also play an important role. In the past decade, several immunoassay methods have been commercialized that may be able to meet most of these criteria (4, 7, 14).The present study was designed to compare the performances of three EBV IgM assays on highly automated random access platforms: BioPlex 2200 (Bio-Rad Laboratories), Immulite 2000 (Siemens Healthcare Diagnostics), and Liaison (DiaSorin). It was performed in a two-phase approach. First, using 363 selected samples we determined the sensitivities and specificities of the EBV IgM assays. In a second approach we prospectively determined the EBV serologic status on samples from 500 different consecutive patients for which EBV IgM determination was requested by general practitioners. 相似文献