首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.

Background

This study aimed to compare the histomorphometric and histological bone response to laser-sintered implants followed by resorbable-blasting media (RBM) process relative to standard machined/RBM surface treated implants.

Material and Methods

Six male sheep (n=6) received 2 Ti-6Al-4V implants (1 per surface) in each side of the mandible for 6 weeks in vivo. The histomorphometric parameters bone-implant contact (BIC) and bone area fraction occupancy (BAFO) were evaluated.

Results

Optical interferometry revealed higher Sa and Sq values for the laser-sintered/RBM surface in relation to standard/RBM implants. No significant differences in BIC were observed between the two groups (p>0.2), but significantly higher BAFO was observed for standard/RBM implants (p<0.01).

Conclusions

The present study demonstrated that both surfaces were biocompatible and osseoconductive, and the combination of laser sintering and RBM has no advantage over the standard machined implants with subsequent RBM. Key words:Dental implants, osseointegration, resorbable- blasting media, sheep, in vivo.  相似文献   

2.

Background

This study histologically evaluated two implant designs: a classic thread design versus another specifically designed for healing chamber formation placed with two drilling protocols.

Material and Methods

Forty dental implants (4.1 mm diameter) with two different macrogeometries were inserted in the tibia of 10 Beagle dogs, and maximum insertion torque was recorded. Drilling techniques were: until 3.75 mm (regular-group); and until 4.0 mm diameter (overdrilling-group) for both implant designs. At 2 and 4 weeks, samples were retrieved and processed for histomorphometric analysis. For torque and BIC (bone-to-implant contact) and BAFO (bone area fraction occupied), a general-linear model was employed including instrumentation technique and time in vivo as independent.

Results

The insertion torque recorded for each implant design and drilling group significantly decreased as a function of increasing drilling diameter for both implant designs (p<0.001). No significant differences were detected between implant designs for each drilling technique (p>0.18). A significant increase in BIC was observed from 2 to 4 weeks for both implants placed with the overdrilling technique (p<0.03) only, but not for those placed in the 3.75 mm drilling sites (p>0.32).

Conclusions

Despite the differences between implant designs and drilling technique an intramembranous-like healing mode with newly formed woven bone prevailed. Key words: Histomorphometry, biomechanical, in vivo, initial stability, insertion torque, osseointegration.  相似文献   

3.

PURPOSE

One of the major keys to achieve successful osseointegration of the implant is its surface properties. The aim of this study was to investigate the bone response to dental implants with different surface characteristics using the rabbit tibia model. Tricalcium phosphate (TCP) coated, anodic oxidized and turned (control) surfaces were compared.

MATERIALS AND METHODS

Seventy two implants were placed in the tibia of eighteen rabbits. Nine rabbits were sacrificed at 3 weeks of healing and the remaining nine were sacrificed at 6 weeks of healing. The bone-to-implant contact (BIC) and the bone volume density (BVD) were assessed by light microscope after 3 and 6 weeks of healing.

RESULTS

Statistical analysis showed that no significant differences in the BIC and BVD were observed between the different implant surfaces and the control group at 3 weeks and 6 weeks of healing. Data also suggested that the BVD of all the surfaces showed significant difference at 3 and 6 weeks.

CONCLUSION

The present study has showed that osseointegration occurred in all investigated types of surface-treated implants. In the current study all of the threads of the implants were observed to calculate BIC and BVD values (instead of choosing some of the threads from the bone cortex for example), which didn''t make BIC or BVD percentage values better than in the control group, therefore the clinical relevance of these results remains to be shown.  相似文献   

4.

PURPOSE

The purpose of this research was to evaluate the amount of reosseointegration after counter torquing (reverse torque) and transposing the installed implants at different times.

MATERIALS AND METHODS

This study was done on ten tibiae of five cross-bred dogs. At the first day one implant was installed in each tibia. After one week half of the implants were randomly counter torqued (1WCT) and the other half were explanted and reimplanted in a new juxtaposition site (transposed)(1WT). At the same time three new implants were installed in each dog, one of them was considered as one week control (1WC) and remaining two as 8 week groups (8WCT&8WT). After eight weeks the 1WCT and 1WT implants were loosened by counter torque and the quantity of needed force for liberation was measured with the digital device (BGI). At the same time one implant was installed in each dog as eight week control (8WC) and the same protocol was repeated for 8 week groups after another 8 weeks.

RESULTS

All implants were osseointegrated. Mean quantities of osseointegration in case groups indicated better amounts rather than control groups.

CONCLUSION

Counter torque or transposition of the installed implants one week or eight weeks after the implantation did lead to osseointegration.  相似文献   

5.
A current goal of dental implant research is the development of titanium (Ti) surfaces to improve osseointegration. Plasma nitriding treatments generate surfaces that favor osteoblast differentiation, a key event to the process of osteogenesis. Based on this, it is possible to hypothesize that plasma-nitrided Ti implants may positively impact osseointegration.

Objective

The aim of this study was to evaluate the in vivo bone response to Ti surfaces modified by plasma-nitriding treatments.

Material and Methods

Surface treatments consisted of 20% N2 and 80% H2, 450°C and 1.5 mbar during 1 h for planar and 3 h for hollow cathode. Untreated surface was used as control. Ten implants of each surface were placed into rabbit tibiae and 6 weeks post-implantation they were harvested for histological and histomorphometric analyses.

Results

Bone formation was observed in contact with all implants without statistically significant differences among the evaluated surfaces in terms of bone-to-implant contact, bone area between threads, and bone area within the mirror area.

Conclusion

Our results indicate that plasma nitriding treatments generate Ti implants that induce similar bone response to the untreated ones. Thus, as these treatments improve the physico-chemical properties of Ti without affecting its biocompatibility, they could be combined with modifications that favor bone formation in order to develop new implant surfaces.  相似文献   

6.

PURPOSE

The purpose of this study was to evaluate bone response to anodized titanium implants coated with the extract of black cohosh, Asarum Sieboldii, and pharbitis semen.

MATERIALS AND METHODS

Forty anodized titanium implants were prepared as follows: group 1 was for control; group 2 were implants soaked in a solution containing triterpenoids extracted from black cohosh for 24 hours; group 3 were implants soaked in a solution containing extracts of black cohosh and Asarum Sieboldii for 24 hours; group 4 were implants soaked in a solution containing extracts of pharbitis semen for 24 hours. The implants from these groups were randomly and surgically implanted into the tibiae of ten rabbits. After 1, 2, and 4 weeks of healing, the nondecalcified ground sections were subjected to histological observation, and the percentage of bone-to-implant contact (BIC%) was calculated.

RESULTS

All groups exhibited good bone healing with the bone tissue in direct contact with the surface of the implant. Group 2 (52.44 ± 10.98, 25.54 ± 5.56) showed a significantly greater BIC% compared to that of group 3 (45.34 ± 5.00, 22.24 ± 2.20) with respect to the four consecutive threads and total length, respectively. The BIC% of group 1 (25.22 ± 6.00) was significantly greater than that of group 3 (22.24 ± 2.20) only for total length.

CONCLUSION

This study did not show any remarkable effects of the extract of black coshosh and the other natural products on osseointegration of anodized titanium implants as coating agents. Further studies about the application method of the natural products on to the surface of implants are required.  相似文献   

7.
The exposing of dental implant into the maxillary sinus combined with membrane perforation might increase risks of implant failure and sinus complications.

Objective

The purpose of this study was to investigate the effects of the dental implant penetration into the maxillary sinus cavity in different depths on osseointegration and sinus health in a dog model.

Material and Methods

Sixteen titanium implants were placed in the bilateral maxillary molar areas of eight adult mongrel dogs, which were randomly divided into four groups according to the different penetrating extents of implants into the sinus cavities (group A: 0 mm; group B: 1 mm; group C: 2 mm; group D: 3 mm). The block biopsies were harvested five months after surgery and evaluated by radiographic observation and histological analysis.

Results

No signs of inflammatory reactions were observed in any maxillary sinus of the eight dogs. The tips of the implants with penetrating depth of 1 mm and 2 mm were found to be fully covered with newly formed membrane and partially with new bone. The tips of the implants with penetrating depth over 3 mm were exposed in the sinus cavity and showed no membrane or bone coverage. No significant differences were found among groups regarding implant stability, bone-to-implant contact (BIC) and bone area in the implant threads (BA).

Conclusions

Despite the protrusion extents, penetration of dental implant into the maxillary sinus with membrane perforation does not compromise the sinus health and the implant osseointegration in canine.  相似文献   

8.

PURPOSE

Dental implant has gained clinical success over last decade with the major drawback related to osseointegration as properties of metal (Titanium) are different from human bone. Currently implant procedures include endosseous type of dental implants with nanoscale surface characteristics. The objective of this review article is to summarize the role of nanotopography on titanium dental implant surfaces in order to improve osseointegration and various techniques that can generate nanoscale topographic features to titanium implants.

MATERIALS AND METHODS

A systematic electronic search of English language peer reviewed dental literature was performed for articles published between December 1987 to January 2012. Search was conducted in Medline, PubMed and Google scholar supplemented by hand searching of selected journals. 101 articles were assigned to full text analysis. Articles were selected according to inclusion and exclusion criterion. All articles were screened according to inclusion standard. 39 articles were included in the analysis.

RESULTS

Out of 39 studies, seven studies demonstrated that bone implant contact increases with increase in surface roughness. Five studies showed comparative evaluation of techniques producing microtopography and nanotopography. Eight studies concluded that osteoblasts preferably adhere to nano structure as compared to smooth surface. Six studies illustrated that nanotopography modify implant surface and their properties. Thirteen studies described techniques to produce nano roughness.

CONCLUSION

Modification of dental osseous implants at nanoscale level produced by various techniques can alter biological responses that may improve osseointegration and dental implant procedures.  相似文献   

9.

Purpose

Electrochemical oxidation following sandblasting and acid-etching (SLA) treatment has received interest as a surface modification procedure for titanium (Ti) implants (denoted as an SLAffinity surface); however, little information is available on its impacts on the in vivo performance of SLAffinity-Ti implants. The present study evaluated the osseointegration and biomechanical bone-tissue response to SLAffinity-Ti implants with micro- and nanoporous oxide layers.

Materials and methods

The interaction between blood and the tested implants was examined. In total, 144 implants with the following surfaces were used: a standard machined (M-Ti), an SLA-Ti, and an SLAffinity-Ti surface. For each animal, four implants (one M-Ti, one SLA-Ti, and two SLAffinity-Ti) were inserted into the mandibular canine-premolar area for histomorphometric observations and another four implants were inserted into the flat surface on the anteromedial aspect of the rear tibia for removal torque (RT) tests. After 2, 4, and 8 weeks of implantation, histomorphometric and RT tests were conducted.

Results

Interactions between blood and implants were better for implants with the SLAffinity-Ti surface. RT tests showed a significant improvement in fixation strength for SLAffinity-Ti implants (84.5?±?8.7 N-cm) after 8 weeks compared to M-Ti (62.95?±?11.5 N-cm) and SLAffinity-Ti (76.1?±?6.6 N-cm) implants. A histological evaluation showed that osseous integration had occurred with all implants after 8 weeks. SLAffinity-Ti implants exhibited 28.5?±?6.2 % bone-to-implant contact (BIC) at 2 weeks and 84.3?±?8.1 % at 8 weeks. M-Ti implants exhibited BIC levels of 17.0?±?5.4 and 76.5?±?6.3 %, whereas SLA-Ti implants exhibited BIC levels of 28.5?±?6.2 and 81.1?±?8.4 % at corresponding time intervals. In terms of the peri-implant bone area (BA), values for SLAffinity-Ti implants ranged from 29.5?±?4.1 to 88.3?±?3.0 %. For M-Ti implants, values ranged from 20.3?±?5.5 to 81.7?±?4.2 %. For SLA-Ti implants, values ranged from 23.0?±?3.5 to 84.0?±?3.6 %.

Conclusions

Electrochemical oxidation increased the oxide layers and improved the blood interaction with SLAffinity-Ti implants, resulting in significantly higher bone apposition with the SLAffinity-Ti implants after 2 and 8 weeks of healing. An increase in resistance for the RT of SLAffinity-Ti implants over the 8-week healing period was also observed.

Clinical relevance

The use of SLAffinity-Ti implants has potential for improvement of early osseointegration.
  相似文献   

10.

STATEMENT OF PROBLEM

Despite an improved bone reactions of Mg-incorporated implants in the animals, little yet has been carried out by the experimental investigations in functional loading conditions.

PURPOSE

This study investigated the clinical and histologic parameters of osseointegrated Mg-incorporated implants in early loading conditions.

MATERIAL AND METHODS

A total of 36 solid screw implants (diameter 3.75 mm, length 10 mm) were placed in the mandibles of 6 beagle dogs. Test groups included 18 Mg-incorporated implants. Turned titanium implants served as control. Gold crowns were inserted 4 weeks after implant placement and the dogs were immediately put on a food diet. Implants were observed for 10 weeks after loading. Radiographic assessments and stability tests were performed at the time of fixture installation, 2nd stage surgery, 4 weeks after loading, and 10 weeks after loading. Histological observations and morphometrical measurements were also performed.

RESULTS

Of 36 implants, 33 displayed no discernible mobility, corresponding to successful clinical function. There was no statistically significant difference between test implants and controls in marginal bone levels (P = .46) and RFA values. The mean BIC% in the Mg-implants was 54.5 ± 8.4%. The mean BIC% in the turned implant was 45.3 ± 12.2%. These differences between the Mg-implant and control implant were statistically significant (P = .005).

CONCLUSIONS

The anodized, Mg-incorporated implant demonstrated significantly more bone-to-implant contact (BIC) in early loading conditions.

CLINICAL IMPLICATIONS

The results of this study in beagle dogs suggest the possibility of achieving predictable stability of early loaded free-standing dental implants with Mg-incorporated surface.  相似文献   

11.

Background

A systematic review is made to determine whether human immunodeficiency virus (HIV) infection has an impact upon dental implant osseointegration.

Material and Methods

A PubMed (MEDLINE) literature search was made of articles published up until 14 April 2014. The systematic review was conducted based on the Preferred Reporting Items for Systematic Reviews and Meta-analysis (PRISMA). The quality of the studies included in the review was assessed using the Methodological Index for Nonrandomized Studies (MINORS) and levels of evidence (based on the University of Oxford’s Center for Evidence Based Medicine criteria).

Results

The combinations of search terms resulted in a list of 132 titles. Nine studies finally met the inclusion criteria and were selected for inclusion in the systematic review. A total of 173 dental implants were placed in 80 patients (135 implants in 56 HIV-positive subjects and 38 implants in 24 HIV-negative patients), and a single loss of dental implant osseointegration was recorded in an HIV-positive patient.

Conclusions

Our results suggest that dental implant placement in HIV-positive patients does not increase the dental implant failure rate. Prophylactic antibiotic treatment, the administration of highly active antiretroviral therapy, and control of the CD4+ T lymphocyte counts appear to be the main influencing factors in this respect. Given the few studies included in our systematic review, further prospective studies involving larger sample sizes and longer durations of follow-up are required in order to confirm the results obtained. Key words: Dental implants, implant failure, HIV positive, systematic review, AIDS, HAART.  相似文献   

12.

Objective

This study investigated the effects of different surface treatments on the tensile bond strength of an autopolymerizing silicone denture liner to a denture base material after thermocycling.

Material and Methods

Fifty rectangular heat-polymerized acrylic resin (QC-20) specimens consisting of a set of 2 acrylic blocks were used in the tensile test. Specimens were divided into 5 test groups (n=10) according to the bonding surface treatment as follows: Group A, adhesive treatment (Ufi Gel P adhesive) (control); Group S, sandblasting using 50-µm Al2O3; Group SCSIL, silica coating using 30-µm Al2O3 modified by silica and silanized with silane agent (CoJet System); Group SCA, silica coating and adhesive application; Group SCSILA, silica coating, silane and adhesive treatment. The 2 PMMA blocks were placed into molds and the soft lining materials (Ufi Gel P) were packed into the space and polymerized. All specimens were thermocycled (5,000 cycles) before the tensile test. Bond strength data were analyzed using 1-way ANOVA and Duncan tests. Fracture surfaces were observed by scanning electron microscopy. X-ray photoelectron spectrometer (XPS) and Fourier Transform Infrared spectrometer (FTIR) analysis were used for the chemical analysis and a profilometer was used for the roughness of the sample surfaces.

Results

The highest bond strength test value was observed for Group A (1.35±0.13); the lowest value was for Group S (0.28±0.07) and Group SCSIL (0.34±0.03). Mixed and cohesive type failures were seen in Group A, SCA and SCSILA. Group S and SCSIL showed the least silicone integrations and the roughest surfaces.

Conclusion

Sandblasting, silica coating and silane surface treatments of the denture base resin did not increase the bond strength of the silicone based soft liner. However, in this study, the chemical analysis and surface profilometer provided interesting insights about the bonding mechanism between the denture base resin and silicone soft liner.  相似文献   

13.

Background

To assess the influence of the crestal or subcrestal placement of implants upon peri-implant bone loss over 12 months of follow-up.

Material and Methods

Twenty-six patients with a single hopeless tooth were recruited in the Oral Surgery Unit (Valencia University, Valencia, Spain). The patients were randomized into two treatment groups: group A (implants placed at crestal level) or group B (implants placed at subcrestal level). Control visits were conducted by a trained clinician at the time of implant placement and 12 months after loading. A previously established standard protocol was used to compile general data on all patients (sex and age, implant length and diameter, and brushing frequency). Implant success rate, peri-implant bone loss and the treatment of the exposed implant surface were studied. The level of statistical significance was defined as 5% (α=0.05).

Results

Twenty-three patients (8 males and 15 females, mean age 49.8±11.6 years, range 28-75 years) were included in the final data analyses, while three were excluded. All the included subjects were nonsmokers with a brushing frequency of up to twice a day in 85.7% of the cases. The 23 implants comprised 10 crestal implants and 13 subcrestal implants. After implant placement, the mean bone position with respect to the implant platform in group A was 0.0 mm versus 2.16±0.88 mm in group B. After 12 months of follow-up, the mean bone positions were -0.06±1.11 mm and 0.95±1.50 mm, respectively - this representing a bone loss of 0.06±1.11 mm in the case of the crestal implants and of 1.22±1.06 mm in the case of the subcrestal implants (p=0.014). Four crestal implants and 5 subcrestal implants presented peri-implant bone levels below the platform, leaving a mean exposed treated surface of 1.13 mm and 0.57 mm, respectively. The implant osseointegration success rate at 12 months was 100% in both groups.

Conclusions

Within the limitations of this study, bone loss was found to be greater in the case of the subcrestal implants, though from the clinical perspective these implants presented bone levels above the implant platform after 12 months of follow-up. Key words:Immediate implants, tooth extraction, dental implants, single-tooth, crestal bone, placement level.  相似文献   

14.

PURPOSE

To evaluate the cumulative survival rate (CSR) and mechanical complications of single-tooth Ankylos® implants.

MATERIALS AND METHODS

This was a retrospective clinical study that analyzed 450 single Ankylos® implants installed in 275 patients between December 2005 and December 2012. The main outcomes were survival results CSR and implant failure) and mechanical complications (screw loosening, fracture, and cumulative fracture rate [CFR]). The main outcomes were analyzed according to age, sex, implant length or diameter, bone graft, arch, and position.

RESULTS

The 8-year CSR was 96.9%. Thirteen (2.9%) implants failed because of early osseointegration failure in 3, marginal bone loss in 6, and abutment fracture in 4. Screw loosening occurred in 10 implants (2.2%), and 10 abutment fractures occurred. All abutment fractures were located in the neck, and concurrent screw fractures were observed. The CSR and rate of screw loosening did not differ significantly according to factors. The CFR was higher in middle-aged patients (5.3% vs 0.0% in younger and older patients); for teeth in a molar position (5.8% vs 0.0% for premolar or 1.1% for anterior position); and for larger-diameter implants (4.5% for 4.5 mm and 6.7% for 5.5 mm diameter vs 0.5% for 3.5 mm diameter) (all P<.05).

CONCLUSION

The Ankylos® implant is suitable for single-tooth restoration in Koreans. However, relatively frequent abutment fractures (2.2%) were observed and some fractures resulted in implant failures. Middle-aged patients, the molar position, and a large implant diameter were associated with a high incidence of abutment fracture.  相似文献   

15.

PURPOSE

In this study, a temporal abutment fixation screw, designed to fracture in a controlled way upon application of an occlusal force sufficient to produce critical micromotion was developed. The purpose of the screw was to protect the osseointegration of immediate loaded single implants.

MATERIALS AND METHODS

Seven different screw prototypes were examined by fixing titanium abutments to 112 Mozo-Grau external hexagon implants (MG Osseous®; Mozo-Grau, S.A., Valladolid, Spain). Fracture strength was tested at 30° in two subgroups per screw: one under dynamic loading and the other without prior dynamic loading. Dynamic loading was performed in a single-axis chewing simulator using 150,000 load cycles at 50 N. After normal distribution of obtained data was verified by Kolmogorov-Smirnov test, fracture resistance between samples submitted and not submitted to dynamic loading was compared by the use of Student''s t-test. Comparison of fracture resistance among different screw designs was performed by the use of one-way analysis of variance. Confidence interval was set at 95%.

RESULTS

Fractures occurred in all screws, allowing easy retrieval. Screw Prototypes 2, 5 and 6 failed during dynamic loading and exhibited statistically significant differences from the other prototypes.

CONCLUSION

Prototypes 2, 5 and 6 may offer a useful protective mechanism during occlusal overload in immediate loaded implants.  相似文献   

16.

Objective

The aim of the present systematic review was to assess the efficacy of parathyroid hormone supplementation on the osseointegration of implants.

Methods

The addressed focused question was Does parathyroid hormone supplementation affect osseointegration around implants? Indexed databases were searched from 1965 up to and including April 2015 using various key words including: Bone to implant contact; implant; parathyroid hormone; and osseointegration. Letters to the Editor, case-reports/case-series, historic reviews, commentaries and articles published in languages other than English were excluded. The pattern of the present systematic review was customized to primarily summarize the pertinent data.

Results

Eighteen studies fulfilled the eligibility criteria. Evidence was limited to preclinical animal studies only (11 studies in rodents, 4 in dogs and 3 in rabbits). Number of titanium implants placed ranged between 20 and 80 implants. Results from 16 studies showed that PTH supplementation enhanced new bone formation and/or BIC around implants. One study suggests that PTH-coated implants improve BIC and BA. One study showed no significant difference in BIC and new bone formation around implants with PTH hydrogel placement.

Conclusion

Efficacy of PTH supplementation on osseointegration of implants shows promising results in animal models, however further investigation is necessary to assess the effectiveness in humans.
  相似文献   

17.

STATEMENT OF PROBLEM

A few of studies which compared and continuously measured the stability of various surface treated implants in the same individual had been performed.

PURPOSE

We aim to find the clinical significance of surface treatments by observing the differences in the stabilization stages of implant stability.

MATERIAL AND METHODS

Eight different surface topographies of dental implants were especially designed for the present study. Machined surface implants were used as a control group. 4 nano-treated surface implants (20 nm TiO2 coating surface, heat-treated 80 nm TiO2 coating surface, CaP coating surface, heat treated CaP coating surface) and 3 micro-treated surface implants [resorbable blast media (RBM) surface, sandblast and acid-etched (SAE) surface, anodized RBM surface] were used as experiment groups. All 24 implants were placed in 3 adult dogs. Periotest® & ISQ values measured for 8 weeks and all animals were sacrificed at 8 weeks after surgery. Then the histological analyses were done.

RESULTS

In PTV, all implants were stabilized except 1 failed implants. In ISQ values, The lowest stability was observed at different times for each individual. The ISQ values were showed increased tendency after 5 weeks in every groups. After 4 to 5 weeks, the values were stabilized. There was no statistical correlation between the ISQ values and PTV. In the histological findings, the bone formation was observed to be adequate in general and no differences among the 8 surface treated implants.

CONCLUSIONS

In this study, the difference in the stability of the implants was determined not by the differences in the surface treatment but by the individual specificity.  相似文献   

18.

STATEMENT OF PROBLEM

A number of studies about the nano-treated surfaces of implants have been conducting along with micro-treated surfaces of implants.

PURPOSE

The purpose of this study was to get information for the clinical use of nano-treated surfaces compared with micro-treated surfaces by measuring removal torque and analyzing histological characteristics after the placement of various surface-treated implants on femurs of dogs.

MATERIAL AND METHODS

Machined surface implants were used as a control group. 4 nano-treated surface implants and 3 micro-treated surface implants [resorbable blast media surface (RBM), sandblast and acid-etched surface (SAE), anodized RBM surface] were used as experimental groups. Removal torque values of implants were measured respectively and the histological analyses were conducted on both 4weeks and 8weeks after implant surgery. The surfaces of removed implants after measuring removal torque values were observed by scanning electron microscopy (SEM) at 8 weeks.

RESULTS

1. Removal torque values of the nano-treated groups were lower than those of micro-treated groups. 2. Removal torque values were similar in the anodized RBM surface groups. 3. On the histological views, there was much of bone formation at 8 weeks, but there was no difference between 4 and 8 weeks, and between the types of implant surfaces as well.

CONCLUSION

It is suggested that implant topography is more effective in removal torque test than surface chemistry. To get better clinical result, further studies should be fulfilled on the combined effect of surface topography and chemistry for the implant surface treatments.  相似文献   

19.

STATEMENT OF PROBLEM

Macroscopic and especially microscopic properties of implant surfaces play a major role in the osseous healing of dental implants. Dental implants with modified surfaces have shown stronger osseointegration than implants which are only turned (machined). Advanced surface modification techniques such as anodic oxidation and Ca-P application have been developed to achieve faster and stronger bonding between the host bone and the implant.

PURPOSE

The purpose of this study was to investigate the effect of surface treatment of titanium dental implant on implant stability after insertion using the rabbit tibia model.

MATERIAL AND METHODS

Three test groups were prepared: sandblasted, large-grit and acid-etched (SLA) implants, anodic oxidized implants, and anodized implants with Ca-P immersion. The turned implants served as control. Twenty rabbits received 80 implants in the tibia. Resonance frequencies were measured at the time of implant insertion, 2 weeks and 4 weeks of healing. Removal torque values (RTV) were measured 2 and 4 weeks after insertion.

RESULTS

The implant stability quotient (ISQ) values of implants for resonance frequency analysis (RFA) increased significantly (P < .05) during 2 weeks of healing period although there were no significant differences among the test and control groups (P > .05). The test and control implants also showed significantly higher ISQ values during 4 weeks of healing period (P < .05). No significant differences, however, were found among all the groups. All the groups showed no significant differences in ISQ values between 2 and 4 weeks after implant insertion (P > .05). The SLA, anodized and Ca-P immersed implants showed higher RTVs at 2 and 4 weeks of healing than the machined one (P < .05). However, there was no significant difference among the experimental groups.

CONCLUSION

The surface-modified implants appear to provide superior implant stability to the turned one. Under the limitation of this study, however, we suggest that neither anodic oxidation nor Ca-P immersion techniques have any advantage over the conventional SLA technique with respect to implant stability.  相似文献   

20.
An important parameter for the clinical success of dental implants is the formation of direct contact between the implant and surrounding bone, whose quality is directly influenced by the implant surface roughness. A screw-shaped design and a surface with an average roughness of Sa of 1-2 µm showed a better result. The combination of blasting and etching has been a commonly used surface treatment technique. The versatility of this type of treatment allows for a wide variation in the procedures in order to obtain the desired roughness.

Objectives

To compare the roughness values and morphological characteristics of 04 brands of implants, using the same type of surface treatment. In addition, to compare the results among brands, in order to assess whether the type of treatment determines the values and the characteristics of implant surface roughness.

Material and methods

Three implants were purchased directly from each selected company in the market, i.e., 03 Brazilian companies (Biomet 3i of Brazil, Neodent and Titaniumfix) and 01 Korean company (Oneplant). The quantitative or numerical characterization of the roughness was performed using an interferometer. The qualitative analysis of the surface topography obtained with the treatment was analyzed using scanning electron microscopy images.

Results

The evaluated implants showed a significant variation in roughness values: Sa for Oneplant was 1.01 µm; Titaniumfix reached 0.90 µm; implants from Neodent 0.67 µm, and Biomet 3i of Brazil 0.53 µm. Moreover, the SEM images showed very different patterns for the surfaces examined.

Conclusions

The surface treatment alone is not able to determine the roughness values and characteristics.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号