首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Abbott RealTime HIV-1 Qualitative is an in vitro real-time PCR assay for detecting HIV-1 nucleic acids in human plasma and dried blood spots (DBS). The assay was designed to be used in diagnosis of HIV-1 infections in pediatric and adult patients, with an emphasis on the applicability in resource-limited settings. Use of DBS facilitates specimen collection from remote areas and transportation to testing laboratories. Small sample input requirement facilitates testing of specimens with limited collection volume. The Abbott RealTime HIV-1 Qualitative assay is capable of detecting HIV-1 group M subtypes A-H, group O and group N samples. HIV-1 virus concentrations detected with 95% probability were 80 copies/mL of plasma using the plasma protocol, and 2469 copies/mL of whole blood using the DBS protocol. The assay detected HIV-1 infection in 13 seroconversion panels an average 10.5 days earlier than an HIV-1 antibody test and 4.9 days earlier than a p24 antigen test. For specimens collected from 6 weeks to 18 months old infants born to HIV-1 positive mothers, assay results using both the DBS and plasma protocols agreed well with the Roche Amplicor HIV-1 DNA Test version 1.5 (95.5% agreement for DBS and 97.8% agreement for plasma).  相似文献   

2.
The early detection of human immunodeficiency virus type 1 (HIV-1) infection in infants is complicated by the persistence of maternal antibodies and by diverse HIV-1 subtypes. We developed a nested, three-monoplex HIV-1 DNA PCR (N3M-PCR) assay to detect diverse HIV-1 subtypes in infants born to infected mothers. We optimized the test for use with dried blood spot (DBS) samples for ease of storage and transport from rural China to central laboratories. Six pairs of primers were designed that targeted env, gag, and pol genes, and the test was run in three reactions with an analytical sensitivity of 10 copies DNA per reaction to cover nine HIV-1 subtypes, A, B, C, D, F, G, CRF01-AE, CRF08-BC, and CRF07-BC. The assay performance was evaluated on 347 DBS specimens from 151 exposed infants in four diverse provinces of China in which multiple subtypes were circulating. The results of this test were compared to those of HIV antibody enzyme immunoassay and Western blotting confirmation for the infants at ≥18 months of age or to convincing clinical and epidemiologic data for deceased infants. The sensitivity of the N3M-PCR assay was 30.0% (3/10) for infants at 48 h after birth, 91.7% (11/12) at 1 to 2 months of age, and 93.7% (15/16) at 3 to 6 months of age. The specificity was 100% (94/94) at all three time points. The PCR reproducibility in the three DNA regions was 100% for samples at 48 h after birth, 96.7% at 1 to 2 months, and 100% at 3 to 6 months of age. The HIV-1 DNA N3M-PCR assay on DBSs offers a simple and affordable approach for early infant HIV-1 diagnosis in regions with diverse HIV-1 circulating subtypes.  相似文献   

3.
Polymerase chain reaction (PCR) is the most sensitive test to diagnose HIV-1 infection among infants born to HIV seropositive mothers. The purpose of this study was to evaluate the use of dried blood spot (DBS) specimens for PCR and to compare it with whole-blood stored in tubes for HIV-1 DNA PCR. Five hundred and seventy-seven whole-blood infant samples were tested using HIV-1 qualitative in-house nested DNA PCR. Three hundred and fifty-nine samples were from infants at 48 hours of birth and 218 samples at second month. All positive samples tested from whole-blood and every fifth negative sample were coated onto filter paper. DNA was extracted from the filter paper and was amplified using in-house nested PCR. Among the whole-blood samples tested using HIV-1 DNA PCR, 19 of 359 (5.29%) samples were HIV-1 positive and 340 (94.7%) were negative at 48 hours of birth. At second month, 19 (8.7%) of the 218 samples were positive and 199 (91.2%) were negative. Using dried filter paper, 18 samples (95%) tested positive from 19 positive samples (using whole-blood) and 1 tested negative at 48 hours of birth. The 68 negative samples tested using whole-blood were also negative in the DBS test (sensitivity 95% and specificity 100%). At second month, 19 were positive and 40 samples (every fifth sample of 199) were negative (sensitivity and specificity, 100%). PCR performed using DNA extracted from filter paper permits the diagnosis of HIV-1 infection among infants born to HIV-1 seropositive mothers. This assay is simple, rapid, sensitive and specific and can be used in resource limited settings.  相似文献   

4.
A plasma HIV-1 RNA amplification assay (RNA assay), a quantitative peripheral blood mononuclear cell (PBMC) microculture (culture), and a PBMC HIV-1 DNA amplification assay (DNA assay) were compared for diagnosis of HIV-1 infection in infants receiving zidovudine in Pediatric AIDS Clinical Trials Group protocol 185; assays were performed for all 24 infected and 100 uninfected infants. HIV-1 infection was defined as >or=2 positive cultures or positive antibody to HIV-1 at >or=18 months. Cultures were performed at birth and 6 and 24 weeks of age; DNA and RNA assays were performed on cryopreserved specimens. The sensitivity of culture and DNA and RNA assays at birth was 20.8%, 10.5%, and 26.7%, respectively. At older ages, sensitivity typically exceeded 80%, remaining highest for the RNA assay (>85%). Assay specificity was >99%. Positive predictive values exceeded 93% for each assay at each age; negative predictive values were highest (>90%) for the RNA assay. At birth (P < 0.005) and age 6 weeks (P < 0.001), a significantly larger proportion of infected infants were identified by means of the RNA assay than by the other assays. The diagnostic performance of the RNA assay matched or exceeded that of culture and the DNA assay. Given that RNA assays require less blood volume and yield rapid results, our study adds to existing data suggesting that RNA assays may be used for early diagnosis of HIV-1 infection in infants.  相似文献   

5.
Dried blood spots (DBS) on filter paper facilitate the collection, transport, and storage of blood samples for laboratory use. A rapid and simple DNA extraction procedure from DBS was developed and evaluated for the diagnosis of human immunodeficiency virus type 1 (HIV-1) infection in children by an in-house nested-PCR assay on three genome regions and by the Amplicor HIV-1 DNA prototype assay version 1.5 (Roche Molecular Systems). A total of 150 samples from children born to HIV-1-infected mothers were collected in Kigali, Rwanda, in parallel as DBS and as peripheral blood mononuclear cell (PBMC) pellets. The results obtained on DBS by the two PCR assays were compared to the results of nested PCR on PBMCs. Of 150 PBMC samples, 10 were positive, 117 were negative, and 23 were indeterminate for HIV-1 infection. In DNA extracted from filter papers and amplified by using the in-house nested PCR, 9 of these 10 positive samples (90%) were found to be positive, and 1 was found to be indeterminate (only the pol region could be amplified). All of the negative samples and all of the 23 indeterminate samples tested negative for HIV-1 infection. When we used the Amplicor DNA test on DBS, all of the 10 PBMC-positive samples were found to be positive and all of the 23 indeterminate samples were found to be negative. Of the PBMC-negative samples, 115 were found to be negative and 2 were found to be indeterminate. We conclude that this simple rapid DNA extraction method on DBS in combination with both detection methods gave a reliable molecular diagnosis of HIV-1 infection in children born to HIV-infected mothers.  相似文献   

6.
The detection of HIV-1 proviral DMA in children born to seropositive mothers was studied using the polymerase chain reaction with either a radioactive electrophoretic method or a novel procedure that employs colorimetric microwell visualization. Peripheral blood mononuclear cell lysates from 18 HIV-1 infected children and 28 uninfected subjects were assayed for a 142 bp fragment of DNA from the gag region of HIV-1 using the primer pair SK145-431. Detection of amplified DNA was carried out by hybridization with a radiolabeled SK102 probe, or with a tagged SK102 probe permitting colorimetric detection. The radioactive detection procedure demonstrated 100% specificity and correlated with the serological results. The assay was more sensitive than the p24 antigen test, but two false negative results were obtained. One was from a sample taken at 2 weeks, an age at which unde-tectable provirus levels were reported in almost all HIV-1 infected newborns. The second was probably due to a low copy number of proviral DNA, as positive results were obtained in all other (6) samples from this child. Comparative analysis in a limited number of specimens of radioactive and colorimetric detection following PCR revealed 100% specificity and comparable sensitivity with 4 discordant results. The results show that PCR is the best method for early diagnosis of HIV-1 infection in pediatric subjects. The study also demonstrated the value of a colorimetric detection method for PCR products. This colorimetric microwell plate procedure may prove a useful technique in routine diagnosis of HIV-1 infection in children. © 1994 Wiley-Liss, Inc.  相似文献   

7.
We performed a comparative analysis between Roche Amplicor HIV-1 DNA test and CAPTAQ assay for the detection of HIV in 830 dried blood spot (DBS) pediatric samples collected in Mozambique. Our results demonstrated no statistical difference between these assays. The CAPTAQ assay approached nearly 100% repeatability/accuracy. The increased throughput of testing with minimal operator interference in performing the CAPTAQ assay clearly demonstrated that this method is an improvement over the Roche Amplicor HIV-1 DNA test, version 1.5.  相似文献   

8.
BACKGROUND: In previous evaluations, the standard Amplicor HIV-1 DNA PCR test (Roche Diagnostic Systems) has been reported to have low sensitivity for the detection of some non-B HIV-1 subtypes. It has therefore become necessary to determine the performance of commercially available as well as prototype HIV-1 PCR assays for HIV-1 DNA detection in samples from various geographical settings, in order to assess their ability to detect the different HIV-1 genotypes. OBJECTIVES: To determine the performance of the prototype Roche Amplicor version 1.5 PCR test in comparison to that of the standard Roche Amplicor PCR test for the detection of HIV-1 DNA in blood samples from HIV-1 seropositive pregnant Tanzanian women infected with various HIV-1 subtypes. STUDY DESIGN: This was a cross-sectional study done on 161 blood samples collected from 106 HIV-1 seropositive and 55 seronegative asymptomatic pregnant women attending antenatal clinic in Dar es Salaam, Tanzania. METHODS: Cell pellets for PCR were prepared from EDTA blood by the Amplicor whole blood PCR sample preparation method. Plasma was used for HIV serology by enzyme linked immunosorbent assays. Subtyping was done by the heteroduplex mobility assay (HMA) using cell pellets and/or plasma. RESULTS: The sensitivities of the prototype PCR and the standard assays were 99.1% (105/106) and 97% (99/102), respectively. All samples from 55 HIV-1 seronegative women were negative by both PCR assays. Among the 101 samples subtyped by HMA, 48 (47%) were subtype A, 30 (30%) subtype C, 20 (20%) subtype D and 3 (3%) were indeterminate. In the standard DNA PCR assay, a statistically significantly higher proportion of subtype A samples had a low level of reactivity as measured as optical density compared with the subtypes C and D samples while in the prototype assay all three subtypes showed a high level of reactivity. CONCLUSIONS: The Amplicor version 1.5 DNA PCR test has a high sensitivity for the detection of HIV-1 DNA in blood samples from Tanzanian adults. Since performance of this assay does not appear to be influenced by differences in HIV-1 subtypes A, C and D, it has the potential for use in the detection of HIV-1 DNA in samples from geographic areas where these subtypes are prevalent.  相似文献   

9.
Effective health care delivery to the majority of perinatally exposed infants worldwide, including those enrolled in prevention of mother-to-child transmission programs, is hampered by lack of access to an HIV diagnosis in infancy. Dried blood spot collection from young infants for centralized HIV polymerase chain reaction (PCR) testing is attainable in low-resource settings, provided PCR methodology suitable for routine laboratory service is available. The accuracy of the Roche Amplicor HIV-1 DNA test version 1.5 (Branchburg, NJ) performed on dried blood spots collected prospectively on ordinary Whatman filter paper from a cohort of 300 6-week-old infants born to HIV-infected women in Johannesburg, South Africa, was assessed. Anonymous analysis of the blood spots using a unique DNA extraction procedure was performed in a routine diagnostic laboratory and the results compared with HIV DNA and RNA PCR liquid blood tests at age 6 weeks, and the HIV status of the infant. Dried blood spots were available for 288 infants (96%) of whom 25 (8.7%) were HIV infected. The Roche Amplicor assay yielded a sensitivity of 100% and a specificity of 99.6%. HIV DNA PCR tests on dried blood spots have the potential to improve health care delivery to HIV-affected children in low-resource settings right now.  相似文献   

10.
The human immunodeficiency virus type 1 (HIV-1) DNA PCR results of 94 dried blood spot (DBS) samples on filter paper and corresponding venous blood in EDTA obtained from infants born to HIV-1-seropositive mothers were compared. In addition, the results of HIV-1 DNA PCR on DBS and the HIV-1 RNA PCR from plasma of 70 paired samples were compared. A 100% specificity and a 95% sensitivity for HIV-1 DNA PCR on DBS compared with results for venous blood were observed for the 94 paired samples. The results of the DBS HIV-1 DNA PCR and HIV-1 RNA PCR of 70 corresponding plasma samples correlated perfectly (100%). The DBS HIV-1 DNA PCR method proved reliable for HIV-1 detection.  相似文献   

11.
OBJECTIVES: To evaluate the sensitivity and specificity of RNA and DNA polymerase chain reaction (PCR) for early diagnosis of perinatal HIV-1 infection and to investigate early viral dynamics in infected infants. DESIGN: A cohort study of 395 non-breastfed infants born to HIV-infected mothers in a randomized clinical trial of short-course antenatal zidovudine. METHODS: Infant venous blood specimens collected at birth, 2 months, and 6 months of age were tested by qualitative DNA and quantitative RNA PCR (Roche Amplicor). To determine sensitivity and specificity of DNA and RNA PCR, results were compared with later DNA PCR results and to antibody results at 18 months. The HIV-1 subtype of the mother's infection was determined by peptide serotyping. RESULTS: In the study, 92% of mothers were infected with subtype E. DNA PCR sensitivity was 38% (20 of 53) at birth, and 100% at 2 months (53 of 53) and 6 months (47 of 47). RNA PCR sensitivity was 47% (25 of 53) at birth and 100% (53 of 53) at 2 months. All samples that tested DNA-positive tested RNA-positive. Specificity was 100% for both DNA and RNA testing at all timepoints. For infected infants, the median viral load of RNA-positive specimens was 407,000 copies/ml (5.6 log10) at birth, 3, 700,000 copies/ml (6.6 log10) at 2 months, and 1,700,000 copies/ml (6.2 log10) at 6 months. Infant RNA levels at 2 and 6 months did not differ by maternal zidovudine exposure, or RNA level at birth. CONCLUSION: This RNA PCR assay performed well for diagnosing perinatal HIV subtype E infection, detecting nearly half of infected infants at birth, and 100% at 2 and 6 months, with 100% specificity. Infected infant viral RNA levels were very high at 2 and 6 months, and were unaffected by maternal zidovudine treatment.  相似文献   

12.
Molecular methods for HIV-1 infection using dried blood-spot (DBS) for HIV-1 CRF01_AE subtypes have not been fully optimized. In this study assays for HIV-1 diagnosis or quantitation were evaluated using infant DBS from Thailand. Paired DBS and whole blood samples from 56 HIV-1 CRF01_AE or B'-infected infants were tested for infant diagnosis using modified Amplicor DNA PCR and NucliSens RNA NASBA and an in-house real-time PCR assay. The Amplicor Monitor viral load (VL) assay, with modifications for DBS, was also evaluated. DBS VL were hematocrit corrected. Stability studies were done on DBS stored at -70 degrees C to 37 degrees C for up to 1 year. The DBS diagnostic assays were 96-100% sensitive and 100% specific for HIV-1 diagnosis. DBS HIV-1 VL were highly correlated with plasma VL when corrected using the actual or an assumed hematocrit factor (r(c)=0.88 or 0.93, respectively). HIV-1 DNA in DBS appeared to be more stable than RNA and could be detected after up to 9 months at most temperatures. DBS VL could be consistently determined when stored frozen. These results show that DBS can be used accurately instead of whole blood for the diagnosis of HIV-1 infection and VL quantitation, particularly if samples are appropriately stored.  相似文献   

13.
The qualitative Roche HIV-1 DNA Amplicor assay has been used for the past 20 years to diagnose HIV infection in infants and young children but is being phased out; hence, alternative assays must be found. The Gen-Probe Aptima qualitative HIV-1 RNA assay is currently the only FDA-cleared HIV-1 nucleic acid assay approved for diagnosis, but data on the use of this assay with infant plasma are limited. We assessed Aptima''s performance using control material for reproducibility and limit of detection and 394 plasma samples (0.2 to 0.5 ml) from HIV-exposed infected and uninfected infants and children for analytical sensitivity and specificity. Assays to assess within-run repeatability and between-run reproducibility indicated that the controls with 10,000 (5 of 5), 200 (5 of 5), 100 (16 of 16), 50 (12 of 12), and 25 (20 of 20) HIV-1 RNA copies/ml (cp/ml) were always positive, and negatives were always negative (20 of 20). The limit of detection was 14 cp/ml, as determined by probit analysis. The analytic sensitivity of the assay was 99.5% (189/190 samples; 95% confidence interval [CI], 97.1 to 99.9%) and specificity was 99.5% (199/200 samples; 95% CI, 97.2 to 99.9%). These results suggest that the assay is suitable for early infant diagnosis of HIV-1.  相似文献   

14.
15.
A dried blood spot (DBS) is a well-accepted means for the collection, transport, and storage of blood samples for various epidemiologic, serologic, and molecular assays for human immunodeficiency virus (HIV) studies. It is particularly important for mother-to-infant-transmission studies of affected individuals living in remote areas. We have developed a real-time PCR method to detect HIV type 1 (HIV-1) DNA in dried blood spots. A cellular gene, RNase P, was coamplified with the HIV-1 DNA in the same tube to monitor the DNA extraction efficiency and the overall assay performance. Our assay is a one-tube, single-step closed-system assay and uses a dUTP/uracil DNA glycosidase anti-PCR contamination control. The HIV-1 primers and probe were derived from a conserved region of the long terminal repeat. The detection of RNase P is attenuated by lowering the forward and reverse primer concentrations so that its amplification will not overwhelm the HIV-1 amplification and yet will provide a semiquantitative measurement of the quality of the isolated DBS DNA. We examined 103 HIV-1-seropositive and 56 seronegative U.S. adults and found that our assay has a sensitivity of 98.1% (95% confidence interval [CI], 95.5% to 100%) and specificity of 100% (95% CI, 99% to 100%). The positive and negative predictive values are 100% and 96.6%, respectively. This duplex PCR assay may be useful in identifying HIV-1-infected persons, particularly infants born to seropositive mothers in remote areas of the world.  相似文献   

16.
Human cytomegalovirus, HCMV, was analysed using real-time quantitative PCR in symptomatic or asymptomatic pediatric cohorts from HIV-1 infected, exposed (HIV-1+ mothers), or uninfected groups in Zambia, an HIV-1/AIDS endemic region of Africa. HCMV infections were identified in 94% samples from HIV-1+ respiratory pediatric mortalities, 50% with high DNA loads of 103-108 copies/106 cells. In comparison, HCMV viremia with high DNA loads, indicative of acute infections, were in 10% hospitalised febrile infants, with 50% HIV-1+. Whereas high sera loads were in 1% of asymptomatic infants, with 2% HIV-1+, and higher levels in both HIV-1 infected or exposed, but negative infants. All 8 linked-hypervariable glycoprotein gN-gO genotypes were shown, including identification of a new gN4d group with gO5 linkage (previously only Merlin reference strain), and samples with multiple infections. Overall, this shows global genotypes in Africa (unlike some herpesviruses) and acute pediatric HCMV infections in both HIV-1+ plus exposed, but uninfected infants, an emerging group.  相似文献   

17.
18.
BackgroundThere is a worldwide need for a pediatric HIV-1 diagnostic test that has a high diagnostic accuracy, is technically simple and cost efficient. The Up24 HIV-1 assay, which requires both the HIV-1 p24 ELISA and the ELAST signal amplification kit, has previously been shown to be a robust tool to diagnose pediatric HIV-1 from dried whole blood spots (DBS) (Cachafeiro et al., JCM 2009;47:459–6213). In order to make the assay more accessible to a resource-limited clinical setting, we eliminated the ELAST system, which simplified the Up24 assay, reduced its cost, and tested the accuracy of the modified assay in a rural Malawian hospital.ObjectivesIn this proof of concept study, we tested the ability of a simplified Up24 antigen assay, without ELAST, to detect HIV-1 on DBS obtained via heel prick from 6-week-old Malawian infants.Study designA case–control study of DBS collected from 113 HIV-infected and 109 HIV-negative infants, using the HIV-1 DNA PCR assay as the reference standard.ResultsThe simplified HIV-1 Up24 assay had a sensitivity and specificity of 84% and 98%, respectively. When HIV-1 prevalence is 15%, the positive- and negative-predictive values are 89% and 97%, respectively.ConclusionThe simplified Up24 assay has a good positive- and a robust negative-predictive values, is easier to perform and has a reduced cost compared to both HIV DNA PCR and Up24 assays. With additional testing, the simplified Up24 assay has the potential to increase global access to pediatric HIV-1 diagnostics.  相似文献   

19.
Risk factors for in utero and intrapartum transmission of HIV   总被引:5,自引:0,他引:5  
OBJECTIVE: To identify predictors of in utero and intrapartum HIV-1 transmission in infants born in the Women and Infants Transmission Study between 1990 and 2000. METHODS: In utero HIV-1 infection was defined as an infant with the first positive HIV-1 peripheral blood mononuclear cell culture and/or DNA polymerase chain reaction assay at 7 days of age or younger; intrapartum infection was defined as having a negative HIV-1 culture and/or DNA polymerase chain reaction assay at 7 days of age or younger and the first positive assay after 7 days of age. RESULTS: Of 1709 first-born singleton children with defined HIV-1 infection status, 166 (9.7%) were found to be HIV-1 infected; transmission decreased from 18.1% in 1990-1992 to 1.6% in 1999-2000. Presumed in utero infection was observed in 34% of infected children, and presumed intrapartum infection, in 66%. Among infected children, the proportion with in utero infection increased over time from 27% in 1990-1992 to 80% (4 of 5) in 1999-2000 (P = 0.072). Maternal antenatal viral load and antiretroviral therapy were associated with risk of both in utero and intrapartum transmission. Controlling for maternal antenatal viral load and antiretroviral therapy, low birth weight was significantly associated with in utero transmission, while age, antenatal CD4 cell percentage, year, birth weight, and duration of membrane rupture were associated with intrapartum transmission. CONCLUSION: Although there have been significant declines in perinatal HIV-1 infection over time, there has been an increase in the proportion of infections transmitted in utero.  相似文献   

20.
The detection of virus is used to diagnose human immunodeficiency virus type 1 (HIV-1) infection in infants due to the persistence of maternal antibodies for a year or more. An HIV-1 DNA PCR assay with simple specimen collection and processing was developed and evaluated. Whole blood was collected on filter paper that lysed cells and bound the DNA, eliminating specimen centrifugation and extraction procedures. The DNA remained bound to the filter paper during PCR amplification. Assays of copy number standards showed reproducible detection of 5 to 10 copies of HIV-1 in 5 microl of whole blood. The sensitivity of the assay did not decrease after storage of the standards on filter paper for 3 months at room temperature or after incubation at 37 or 45 degrees C for 20 h. The primers used for nested PCR of the HIV-1 pol gene amplified templates from a reference panel of multiple HIV-1 subtypes but did not amplify a subtype A or a subtype C virus from children living in Seattle. The assay had a sensitivity of 98.4% and a specificity of 98.3% for testing of 122 specimens from 35 HIV-1-infected and 16 uninfected children and 43 seronegative adults living in Washington. The assay had a sensitivity of 99% and a specificity of 100% for testing of 102 HIV-1-positive (as determined by enzyme immunoassay) Peruvian women and 6 seropositive and 34 seronegative infants. This assay, with adsorption of whole blood to filter paper and no specimen processing, provides a practical, economical, sensitive, and specific method for the diagnosis of HIV-1 subtype B infection in infants.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号