首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
BACKGROUND AND PURPOSE: First-pass contrast-enhanced MR angiography has become the technique of choice for studying the carotid bifurcation, but this method has some limitations. We evaluated the clinical utility of performing 3D contrast-enhanced MR angiography in the axial plane immediately after performing angiography in the coronal plane. METHODS: Cervical carotid arteries of 80 consecutive patients were studied on a 1.5-T MR imager with phased-array coils. Coronal 3D MR angiography was performed after administering a bolus injection of contrast material (20 mL) with automatic triggering. This was immediately followed by an axial acquisition. We measured carotid diameters on the contrast-enhanced MR angiograms as well as on intra-arterial digital subtraction angiograms according to established criteria. We also evaluated original source MR angiograms. RESULTS: Angiograms obtained in the axial plane correlated better with the intra-arterial digital subtraction angiograms than did the coronal angiograms. When first-pass contrast-enhanced MR angiography was incomplete because of a failure of triggering, the second-phase acquisition provided sufficient image quality. Original source images suffered from ring artifacts, low axial resolution, and a low level of soft-tissue visualization. Axial-based source images showed flow-independent contrast filling to the patent lumen with sufficient visualization of plaque morphology, thickened arterial wall, and surrounding disease processes, such as tumors. CONCLUSION: With the addition of a 1-minute second-phase 3D acquisition in a different plane immediately after first-pass contrast-enhanced MR angiography, one can obtain a more accurate depiction of the carotid bifurcation, insurance against failure of triggering, and diagnostic source images.  相似文献   

2.
This study was designed to optimize three-dimensional (3D) time-of-flight (TOF) magnetic resonance angiography (MRA) sequences and to determine whether contrast-enhanced MRA could improve the accuracy of lumen definition in stenosed carotid arteries of minipigs. 3D TOF MRA was acquired with use of either an intravascular (n = 13) and/or an extravascular contrast agent (n = 5) administrated at 2 to 4 weeks after balloon-induced injury to a carotid artery in 16 minipigs. Vascular contrast, defined as signal intensity differences between blood vessels and muscle normalized to the signal intensity of muscle, was compared before and after the injection of each contrast agent and between the two agents. Different vascular patencies were observed among the animals, including completely occluded vessels (n = 5), stenotic vessels (n = 3), and vessels with no visible stenosis (n = 8). Superior vascular contrast improvement was observed for small arteries and veins and for large veins with the intravascular contrast agent when compared with the extravascular contrast agent. In addition, preliminary studies in two of the animals showed a good correlation for the extent of luminal stenosis defined by digital subtraction angiography compared with MRA obtained after administration of the intravascular contrast agent (R2 = .71, with a slope of .96 ± .04 by a linear regression analysis). We concluded that use of an intravascular contrast agent optimizes 3D TOF MRA and may improve its accuracy compared with digital subtraction angiography.  相似文献   

3.
PURPOSE: To optimize and determine the value of dual-phase contrast material-enhanced three-dimensional (3D) magnetic resonance (MR) angiography for preoperative evaluation of the blood supply to the liver. MATERIALS AND METHODS: Dual phase 3D MR angiography of the hepatic arteries and portal vein was performed in 140 patients. In 80 patients, the value of fat saturation, digital image subtraction, an anticholinergic agent, and a high-caloric meal were evaluated. In the next 60 patients, MR angiographic and digital subtraction angiographic (DSA) image quality and diagnostic value were compared. RESULTS: Fat-saturated images were of significantly better quality (P < .01) than non-fat-saturated images. Digital image subtraction was useful in only 23 of 40 patients. The injection of an anticholinergic agent was superfluous, whereas administration of a high-caloric meal helped in demonstration of the superior mesenteric artery and portal vein. Classification on MR angiograms of the arterial blood supply was correct in 57 of 60 patients. All arterial and portal venous lesions were seen on MR angiograms, and MR angiograms had a significantly higher subjective image-quality ranking than did DSA images in the evaluation of the portal vein (P < .05). CONCLUSION: Fat saturation and use of a high-caloric meal improve the results of MR angiography of hepatic vessels. MR angiography was comparable to DSA for evaluation of the arterial system and was superior for demonstration of the portal vein; therefore, MR angiography could replace intraarterial DSA.  相似文献   

4.
We describe a novel physical basis and methodology for gadolinium (Gd)-enhanced MRA, which we call "off-resonance contrast angiography" (ORCA). Unlike standard contrast-enhanced (CE) MR angiography (MRA), ORCA contrast depends not on T(1) but on Gd-induced shifts in intravascular resonance frequency due to the bulk magnetic susceptibility (BMS) effects of Gd. The method was tested at 3 Tesla in phantoms with a range of dilutions of Gd-DTPA and ultrasmall iron oxide contrast agent (CA). With the use of ORCA, complete background suppression was obtained without image subtraction. As a result, catheters filled with various Gd dilutions proved to be highly conspicuous in ORCA projection images. This feature may make ORCA particularly attractive for passive catheter tracking during MR-guided endovascular procedures. Gd-induced intravascular frequency shifts were measured in human subjects and found to be in the expected range. ORCA was used to create angiograms of forearm veins that were comparable in quality to standard CE-MRA. In addition, ORCA images of the extracranial carotid bifurcation were successfully acquired during intravenous contrast administration. However, significant technical restrictions also exist, including a dependence on vessel orientation with respect to B(0), and sensitivity to static field inhomogeneities. Further study is needed to determine the practicality and potential clinical utility of this method.  相似文献   

5.
BACKGROUND AND PURPOSE: Since 1996, several preliminary studies have shown the usefulness of contrast material-enhanced MR angiography for imaging supraaortic vessels. The aim of this study was to compare the accuracy of contrast-enhanced 3D MR angiography with that of digital subtraction angiography (DSA) in the evaluation of carotid artery stenosis. METHODS: A blinded comparison of first-pass contrast-enhanced MR angiography with conventional DSA was performed in 120 patients (240 arteries). MR angiography was performed with a 1.5-T magnet with gradient overdrive equipment, by using a coronal radiofrequency-spoiled 3D fast low-angle-shot sequence after the intravenous injection of gadodiamide. The guidelines of the North American Symptomatic Carotid Endarterectomy Trial for measuring stenosis of the internal carotid artery were applied on maximum intensity projection (MIP) images and conventional catheter angiograms. RESULTS: Grading of stenoses on MR angiograms agreed with grading of stenoses on DSA images in 89% of arteries. In the severe stenosis group (70-99%), agreement was 93%. All internal carotid occlusions (n = 28) and seven of nine pseudo-occlusions were accurately detected with contrast-enhanced MR angiography. The correlation between MR angiography and DSA for determination of minimal, moderate, and severe stenoses and occlusion was statistically significant (r = 0.91, P<.001). CONCLUSIONS: This investigation with a large number of patients confirms that contrast-enhanced MR angiography could become a diagnostic alternative to DSA in the treatment of patients with carotid artery disease.  相似文献   

6.
PURPOSE: To obtain high-spatial-resolution, venous-suppressed, contrast material-enhanced, three-dimensional (3D) magnetic resonance (MR) angiograms of the carotid arteries and aortic arch by using an elliptic centric view ordering with MR fluoroscopic triggering. MATERIALS AND METHODS: Forty consecutive patients with cerebrovascular disease in the differential diagnosis were evaluated with fluoroscopically triggered 3D MR angiography (gadoteridol dose range, 0.1-0.3 mmol per kilogram of body weight; mean acquisition time, 40 second +/- 8 [SD]). The contrast-enhanced 3D MR angiograms were evaluated for overall quality, vascular signal intensity, venous suppression, and motion artifact. Twenty patients also underwent two-dimensional (2D) time-of-flight (TOF) MR angiography. The overall quality of the 2D TOF MR angiograms and comparative quality between the 2D TOF and contrast-enhanced 3D MR angiograms were determined. RESULTS: The contrast-enhanced 3D MR angiograms were of excellent or more than adequate quality for diagnosis in 36 of the 40 studies (90%). In 35 of the 38 contrast-enhanced 3D studies in which the contrast material bolus was detected fluoroscopically, the internal jugular vein signal intensity was either not detectable or barely visible. In 18 of the 20 patients who also underwent 2D TOF MR angiography, the quality of the contrast-enhanced 3D MR angiograms was graded as markedly superior or superior. CONCLUSION: Contrast-enhanced, elliptic centric 3D MR angiography with real-time MR fluoroscopic triggering offers high-spatial-resolution images of the carotid arteries and aortic arch with reliable venous suppression.  相似文献   

7.
RATIONALE AND OBJECTIVES: To evaluate prospectively diagnostic accuracy of 1 mol/L gadobutrol as a contrast agent for intraarterial x-ray digital subtraction angiography (DSA) in comparison to iodinated, nonionic contrast media and 0.5 mol/L gadolinium-DTPA. METHODS: Flush arteriograms (ascending, descending, abdominal aorta, iliac, and femoral arteries) and selective angiograms (carotid, renal, and visceral arteries) were obtained from bilateral femoral arterial access (5 F sheaths) in 10 domestic pigs (70 kg body weight). Digital subtracted angiograms were obtained during injection of undiluted 1 mol/L gadobutrol, 300 mg I/mL iopromide, or 0.5 mol/L gadopentetate. Injection parameters (volume and velocity) were similar for all three contrast agents. In paired arteries, two different contrast media were used during the same angiographic run. Diagnostic quality and accuracy of the angiograms were evaluated on a three-step scale by three independent blinded investigators. RESULTS: Sufficient nonselective angiographic images were obtained in 90% of cases using iodinated contrast material. Gadobutrol achieved sufficient nonselective angiograms in 64%. Selective angiograms were sufficient in 98% using iodinated contrast material, 90% using 1 mol/L Gadobutrol and 48% using 0.5 mol/L Gd-DTPA. Adverse reactions to any of the used contrast agents were not noted. CONCLUSION: One mol/L Gadobutrol solution allows x-ray digital subtraction angiography with a diagnostic accuracy equivalent to 300 mg/mL iodinated contrast media, if selective injections are performed. Flush aortograms are of inferior image quality to iodinated contrast material.  相似文献   

8.
The objective of this study was to evaluate quantitatively and qualitatively the effect of image subtraction on the image quality of three-dimensional (3D) gadolinium-enhanced MR angiograms of the renal arteries. Breath-hold 3D gadolinium MR angiography (MRA) as well as conventional contrast angiography of the renal arteries was performed on 20 patients with suspected renovascular hypertension. MR angiograms were acquired before and during dynamic infusion of gadolinium-diethylenetriamine pentaacetic acid (Gd-DTPA). Contrast-enhanced images were compared with images that had undergone voxel-by-voxel signal intensity subtraction of contrast-enhanced data from precontrast data. One false positive finding for significant renal artery stenosis was recorded with MRA using conventional angiography as the gold standard. Image subtraction did not alter the diagnosis at MRA in any case. The mean contrast-to-noise ratio (CNR) was significantly higher (P < .05) on the subtraction MR angiograms compared to the nonsubtracted MR angiograms. There was no significant difference in the signal-to-noise ratio (SNR). Qualitative analysis revealed a significant improvement in image quality after image subtraction with respect to visualization of the distal renal arteries. In conclusion, image subtraction improves the quality of renal MRA in terms of both CNR and visualization of the distal renal arteries.  相似文献   

9.
INTRODUCTION: The aneurysms of visceral vessels are characterized by few or no symptoms and the diagnosis is often occasional. We investigated the usefulness of CT angiography in the diagnosis and preoperative assessment of this condition. MATERIALS AND METHODS: From January 1993 to March 1998, twenty-five patients (aged 32-69 years) with 28 aneurysms underwent CT angiography before and after contrast agent injection to study lesion number, site, size, neck, intraluminal thrombosis and wall calcifications. Data from axial images were postprocessed on an external work-station to obtain CT angiograms. CT angiography findings were analyzed with a double blinded method by 2 radiologists comparing CT angiography with digital subtraction angiography images and evaluating the information obtained from Multiplanar (MPR), Maximum Intensity Projection (MIP) and Shaded Surface Display (SSD) reconstructions. Surgical findings were available for 10 patients. RESULTS: There was complete agreement between CT angiography and digital subtraction angiography in the identification of all lesions; the correlation rate was 94.42% for lesion location, 89.28% for lesion size, 85.71% for detection of endoluminal thrombosis and 82.14% for identification of wall calcifications. Axial and MPR images were useful in the assessment of ali parameters, while MIP images accurately demonstrated wall calcifications and the lesion relationships with adjacent structures. No additional information was obtained from SSD reconstructions. CONCLUSIONS: In our experience CT angiography can replace digital subtraction angiography in the diagnosis and preoperative work-up of visceral vessels aneurysms. CT angiography was superior to digital angiography in the evaluation of the lesion exact dimensions in cases with large thrombotic component and diffuse wall calcifications.  相似文献   

10.
BACKGROUND AND PURPOSE: High-resolution, vascular MR imaging of the spine region in small animals poses several challenges. The small anatomic features, extravascular diffusion, and low signal-to-noise ratio limit the use of conventional contrast agents. We hypothesize that a long-circulating, intravascular liposomal-encapsulated MR contrast agent (liposomal-Gd) would facilitate visualization of small anatomic features of the perispinal vasculature not visible with conventional contrast agent (gadolinium-diethylene-triaminepentaacetic acid [Gd-DTPA]). METHODS: In this study, high-resolution MR angiography of the spine region was performed in a rat model using a liposomal-Gd, which is known to remain within the blood pool for an extended period. The imaging characteristics of this agent were compared with those of a conventional contrast agent, Gd-DTPA. RESULTS: The liposomal-Gd enabled acquisition of high quality angiograms with high signal-to-noise ratio. Several important vascular features, such as radicular arteries, posterior spinal vein, and epidural venous plexus were visualized in the angiograms obtained with the liposomal agent. The MR angiograms obtained with conventional Gd-DTPA did not demonstrate these vessels clearly because of marked extravascular soft-tissue enhancement that obscured the vasculature. CONCLUSIONS: This study demonstrates the potential benefit of long-circulating liposomal-Gd as a MR contrast agent for high-resolution vascular imaging applications.  相似文献   

11.
PURPOSE: To retrospectively compare three-dimensional gadolinium-enhanced magnetic resonance (MR) angiography, performed with an integrated parallel acquisition technique for high isotropic spatial resolution, with selective digital subtraction angiography (DSA) and intravascular ultrasonography (US) for accuracy of diameter and area measurements in renal artery stenosis. MATERIALS AND METHODS: The study was approved by the institutional review board, and consent was obtained from all patients. Forty-five patients (17 women, 28 men; mean age, 62.2 years) were evaluated for suspected renal artery stenosis. Three-dimensional gadolinium-enhanced MR angiograms were acquired with isotropic spatial resolution of 0.8 x 0.8 x 0.9 mm in 23-second breath-hold with an integrated parallel acquisition technique. In-plane diameter of stenosis was measured along vessel axis, and perpendicular diameter and area of stenosis were assessed in cross sections orthogonal to vessel axis, on multiplanar reformations. Interobserver agreement between two radiologists in measurements of in-plane and perpendicular diameters of stenosis and perpendicular area of stenosis was assessed with mean percentage of difference. In a subset of patients, degree of stenosis at MR angiography was compared with that at DSA (n = 20) and intravascular US (n = 11) by using Bland-Altman plots and correlation analyses. RESULTS: Mean percentage of difference in stenosis measurement was reduced from 39.3% +/- 78.4 (standard deviation) with use of in-plane views to 12.6% +/- 9.5 with use of cross-sectional views (P < .05). Interobserver agreement for stenosis grading based on perpendicular area of stenosis was significantly better than that for stenosis grading based on in-plane diameter of stenosis (mean percentage of difference, 15.2% +/- 24.2 vs 54.9% +/- 186.9; P < .001). Measurements of perpendicular area of stenosis on MR angiograms correlated well with those on intravascular US images (r(2) = 0.90). CONCLUSION: Evaluation of cross-sectional images reconstructed from high-spatial-resolution three-dimensional gadolinium-enhanced MR renal angiographic data increases the accuracy of the technique and decreases interobserver variability.  相似文献   

12.
The application of a contrast-enhanced, two-dimensional MR technique, which provides dynamic projection angiograms at a subsecond temporal frame rate for depiction of the cervical and intracranial arteries, was evaluated in three healthy volunteers and seven patients with various cervicocranial steno-occlusive diseases. Intra-arterial digital subtraction angiography (DSA) served as standard of reference for findings in the patients. Magnetic resonance projection angiography (MRPA) was performed on a standard 1.5-T clinical MR imaging system at intravenous injection of a single dose of contrast agent (0.1 mmol/kg GdDTPA-BMA). Sixty consecutive images of the cerebral circulation were acquired at a temporal frame rate of 900 ms per image in the coronal plane. The collateral flow and the perfusion of the compromised vessel territory were readily assessed by MPRA in patients with occlusion of the internal cerebral artery (ICA) or middle cerebral artery (MCA). The leptomeningeal collateralisation of these patients was displayed in a dynamic fashion. Furthermore, quantitative perfusion measurement provided a difference between both MCA territories in the time to peak (ΔDTTP) of the contrast bolus of 1.12 ± 0.28 s in five patients with severe stenosis or occlusion of the ICA (healthy volunteers 0.19 ± 0.05 s). However, important pathological findings, such as the evaluation of carotid artery stenoses and the intracranial collateral flow pattern in patients with severe carotid stenoses, were not sufficiently assessable as compared with DSA. We conclude that the possibility of obtaining simultaneously information about morphology and perfusion dynamics of the cervicocranial vessels is unique in MPRA as compared with other MR techniques. However, in the applied form, the technique is not a reliable tool for the complete evaluation of the cervicocranial vessels in patients with steno-occlusive disease. Received: 27 January 2000/Revised: 11 July 2000/Accepted: 13 July 2000  相似文献   

13.
PURPOSE: The purpose of this study was to compare contrast enhanced MR angiography (MRA) with gadopentetate dimeglumine (Gd-DTPA) to MRA with gadobenate dimeglumine (Gd-BOPTA), a high relaxivity paramagnetic contrast agent. MATERIALS AND METHODS: Twelve patients referred for carotid artery stenosis were examined with MR angiography using a fast spoiled gradient echo sequence. Gd-DTPA and Gd-BOPTA enhanced MR angiography were performed within 48-72 hours using a dose of 0.1 mmol/kg for Gd-BOPTA and 0.2 mmol/kg for Gd-DTPA, at a flow rate of 2 ml/s. Images were evaluated by two blinded radiologists. Qualitative and quantitative evaluations were performed comparing the sets of images from the two examinations. RESULTS: Qualitative evaluation demonstrated superior arterial contrast enhancement and vessel conspicuity with Gd-BOPTA compared with Gd-DTPA. Quantita-tive evaluation showed an improvement in both signal intensity and contrast to noise ratio with Gd-BOPTA. CONCLUSION: The greater relaxivity of Gd-BOPTA, at lower doses, compared with Gd-DTPA, provides higher intravascular signal and signal to noise ratio. Gd-BOPTA appears to be an optimal contrast agent for contrast enhanced MRA.  相似文献   

14.
PURPOSE: To prospectively evaluate the accuracy of intraarterial magnetic resonance (MR) angiography in the depiction of significant stenoses and occlusions, with intraarterial digital subtraction angiography (DSA) serving as the reference standard. MATERIALS AND METHODS: Approval of the local ethics committee and informed consent were obtained. Twenty patients (11 men; nine women; age range, 48-86 years; mean age, 69.5 years+/-11.2 [standard deviation]) with symptomatic peripheral arterial occlusive disease (PAOD) were prospectively enrolled. After percutaneous transluminal angioplasty (PTA), intraarterial MR angiography was performed in the thigh and the calf with a 1.5-T MR imager in two consecutive runs. Intraarterial MR angiography was performed with a low-dose injection protocol (ie, two 20-mL injections of a 50-mmol gadolinium-based contrast agent). Moderate stenoses (luminal narrowing50%) or vessel occlusions; 95% confidence intervals (CIs) were calculated for sensitivity and specificity. RESULTS: Intraarterial DSA revealed 78 moderate stenoses, 57 significant stenoses, and 28 occlusions. Sensitivity, specificity, and accuracy of intraarterial MR angiography in the characterization of significant stenoses or occlusions were 92% (95% CI: 72%, 99%), 94% (95% CI: 82%, 98%), and 93%, respectively, in femoropopliteal arteries and 93% (95% CI: 83%, 98%), 71% (95% CI: 51%, 86%), and 86%, respectively, in infrapopliteal arteries. The main artifact observed with intraarterial MR angiography was venous contamination (12%). CONCLUSION: Intraarterial MR angiography is an accurate method used to depict significant stenoses and occlusions in lower extremity arteries with a low-dose injection protocol.  相似文献   

15.
BACKGROUND AND PURPOSE: Three-dimensional time-of-flight (TOF) MR angiography has been evaluated in the follow-up of intracranial aneurysms treated with Guglielmi detachable coils (GDCs) with good results. Some of the studies used contrast material in addition to the 3D TOF MR technique and others did not. We assessed the usefulness of contrast material with 3D TOF MR angiography by comparing this sequence before and after contrast material injection. METHODS: Fifty-eight patients harboring a total of 71 cerebral aneurysms previously treated with GDCs were included in the prospective study. MR angiography (at 1.5 T) was performed with a 3D TOF sequence before and after injection of gadolinium-based contrast material. Features evaluated were presence and size of a neck remnant, parent and adjacent vessel patency, and venous overlap. Digital subtraction angiography was the standard of reference. RESULTS: Comparison of the techniques showed a good agreement in the detection of residual flow. Six cases of small residual neck were not detected with either the 3D TOF or the contrast-enhanced 3D TOF sequence. In one case of giant aneurysm, the extent of recanalization was more evident after contrast material administration. The use of contrast material did not help to show the parent and adjacent arteries. Venous overlap on contrast-enhanced 3D TOF angiograms did not affect image interpretation. CONCLUSION: In this series, the use of intravenous contrast material did not improve the ability of 3D TOF MR angiography to depict the presence of residual or recurrent aneurysms previously treated with endovascular coiling. In one giant aneurysm, use of intravenous contrast material did result in improved visualization of a residual aneurysm.  相似文献   

16.
Initial evaluation of a new blood pool agent, B-22956/1, for pulmonary imaging was performed in five domestic pigs with artificial embolism. Pre-embolism 3D pulmonary perfusion images were first acquired by injecting an extravascular agent, gadoteridol. The pulmonary arteries of the pigs were then occluded by the artificial emboli. Post-embolism perfusion scans were subsequently performed by injecting B-22956/1. Additional post-embolism high-spatial-resolution angiograms were also acquired. Parenchyma perfusion deficits were well depicted in the post-embolism perfusion maps. The post-embolism angiography clearly revealed the location and extent of the filling defects in the pulmonary vessels. Signal intensities of perfusion maps on the normal parenchyma were significantly improved (30%) by using B-22956/1, in comparison with perfusion images using gadoteridol (P < 0.01). Many pulmonary angiograms with approximately equal contrast could be obtained even at 22 minutes after the injection of B-22956/1. Our initial results indicate that blood pool agent B-22956/1 may provide opportunities for whole-lung-coverage perfusion mapping and additional high-resolution target angiograms after a single injection.  相似文献   

17.
The purpose of this study was to prospectively evaluate the diagnostic accuracy of reader detection of 75% or greater stenosis at high-spatial-resolution multistation magnetic resonance (MR) angiography performed with matrix coils and a blood pool contrast agent. Ten healthy volunteers and 10 patients were examined. All participants provided informed consent to participate in this institutional review board-approved study. For contrast agent-enhanced multistation MR angiography, an albumin-binding gadolinium chelate, gadofosveset trisodium, was used. Imaging was performed during the first-pass and steady-state phases of the contrast agent. Vessel conspicuity on the first-pass MR angiograms obtained in both volunteers and patients was rated as excellent for 93% of vessels. At steady-state imaging, vessel conspicuity was rated as excellent or good for 89% of vessels. Gadofosveset trisodium-enhanced MR angiography yielded sensitivities of 100% and 97% and specificities of 96% and 97% for detection of significant disease in the carotid and lower extremity arteries, respectively.  相似文献   

18.
Purpose: To assess the feasibility of intra-arterial magnetic resonance angiography (iaMRA) with two different protocols.

Material and Methods: Twenty patients were prospectively examined after digital subtraction angiography. Contrast-enhanced iaMRA was performed using a 1.5T magnetic resonance imaging (MRI) system. Contrast agent (gadodiamide) was injected through a conventional angiography catheter placed in the abdominal aorta. The patients were randomized into two groups each comprising 10 patients. Group 1 was examined with a FLASH-3D (fast low-angle shot) sequence, allowing the center of the k-space to be acquired 0.5 s after initiation of the measurement. Group 2 was examined with the identical sequence, but the center of the k-space was acquired after 8.7 s. The increase in the intravascular signal intensity was determined and the diagnostic value of the angiograms was independently scored by 4 investigators using a 5-point scale.

Results: Nineteen of 20 MRAs were scored as diagnostic; only 1 was scored as non-diagnostic by 2 observers. The diagnostic value of the angiograms of group 2 was judged superior to that of group 1 owing to a more homogeneous intravascular contrast distribution.

Conclusion: Intra-arterial MRA is feasible. The diagnostic value of angiograms using a flash sequence with center of the k-space acquisition after 8.7 s ranged from good to excellent. This sequence is appropriate for iaMRA of iliac arteries to support MR guided intervention.  相似文献   

19.
A system for three-dimensional (3D) presentation of intravascular ultrasound (US) images was designed. A standard hardware configuration based on personal computer equipment was used for acquisition and processing of image data. Pullback imaging with the US catheter was controlled by a specially designed motor assembly and performed either in equidistant 1–10 mm steps or at a constant retraction speed. Curvature of the vessel was documented on biplane digital subtraction angiograms and the US images were arranged according to the vessel shape in the angiograms. 3D reconstruction appears essential for spatial orientation of intravascular US and may be helpful in the planning of vascular interventions for a better appreciation of the extent and morphology of vascular lesions.  相似文献   

20.
We investigated intravenous digital angiography using computer processed fluoroscopic images. Computer processed fluoroscopy (CPF) was compared to conventional digital subtraction angiography (DSA) in 39 patients referred for renal vessel evaluation. For assessment of CPF the anterior-posterior images were compared with the corresponding digital subtraction angiograms. 79% percent of DSA and 71% of CPF studies were diagnostic. Peripheral injection of contrast medium caused deterioration of CPF images. Skin dose measurements were obtained in 24 patients. The median dose for DSA was 8.2 rad, compared to 1.1 rad for CPF. It is concluded that sophisticated algorithms should be investigated for digital angiography, so that high image quality can be achieved with a reduced radiation exposure.  相似文献   