首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 234 毫秒
1.
Temporal acuity, defined as the minimum detectable gap in an otherwise continuous noise, was measured with an adaptive version of the two-alternative forced-choice task. For 6 normal listeners, the minimum duration detectable decreased from an average of 20.3 ms at a noise level of 30 dB SPL to 3.2 ms at 80 dB SPL. By comparison, the temporal acuity of 4 listeners with conductive hearing losses, 2 with otosclerosis, and 7 with sensorineural hearing losses, was poorer than that for normal listeners at equal sound pressure levels. At higher sound pressure levels, the acuity of those with conductive hearing losses or otosclerosis approached normal values, but the acuity for listeners with sensorineural hearing losses did not.

Nous avons mesuré l'acuité temporelle, définie comme la durée minimale d'une interruption d'un bruit par ailleurs continu pour qu'elle soit décelable, en appliquant une version particulière de la méthode des choix forcés entre deux alternatives. Chez 6 sujets jouissant d'une audition normale, ce temps passait en moyenne de 20,3 ms pour un bruit de 30 dB SPL à 3,2 ms pour un bruit de 80 dB SPL. Dans 4 cas de surdité de transmission, 2 cas d'otospongiose et 7 cas d'atteinte de l'oreille interne, nous avons trouvé une acuité temporelle moins bonne aux měmes intensités de bruit. Dans les cas de surdité de transmission et d'otospongiose, les valeurs se rapprochaient de la normale à des intensités de son plus élevées, mais il n'en était pas de měme pour les malades souffrant d'atteintes de l'oreille interne.  相似文献   

2.
15 patients suffering from definite multiple sclerosis were studied by electrocochleography (ECochG) and brain stem electric responses (BSER), including objective analysis of the electrophysiological data. In 7 patients, both ECochG and BSER were performed, in 2 only ECochG and in 6 only BSER. Systematic deviations from normative values were found in all 9 patients tested by ECochG, but the deviations occurred only at 75 dB pe SPL or below. Despite normal or near-normal audiometric thresholds, the cochleae seemed to be involved. At click intensities of 95 dB pe SPL or higher, the BSER revealed a normal AP-V (Jewett) interval in all 13 patients tested. However, a deviant configuration of the BSER following the wave V complex was found in 6 of the 13 patients. The deviation is described as a dominant, relatively low-frequency component of the response. The discrepancies between these results and those reported in the literature indicate a strong need for applying methods that compensate for peripheral hearing dysfunctions and objective methods of analysis to identify and evaluate the various components of the evoked potentials.

Chez 15 malades atteints de sclérose en plaque déclared, nous avons pratique I'ECochG et/ou BER, avec chaque fois une analyse objective des réponses électrophysiologiques. Graˇce a I'ECochG, nous avons trouvé des anomalies au niveau de l'organe auditif périphérique chez tous les malades examinés, et ce malgré des résultats d'audiométrie standard normaux ou presque. Avec les réponses évoquées du tronc cérébral (BER) nous avons trouvé, dans la moitié des cas à peine, des ondes V de Jewett d'allure anormale mais de latence normale par rapport à celle du potentiel d'action dans tous les cas. Nos résultats, qui sont différents de ceux rapportés dans la litérature, nous amènent à penser que lorsqu' on veut évaluer les données BER dans un but diagnostique, il est important d'utiliser des méthodes qui compensent les atteintes périphériques des voies auditives et que, d'une façon générate, lorsqu'il s'agit d'analyser des réponses électrophysiologiques, il est important d'utiliser des méthodes ou des critères objectifs.  相似文献   

3.
The present study consisted of two experiments. Experiment I was directed toward the detection of subtle mid-frequency cochlear dysfunction and the determination of word discrimination in noise for persons with noise-induced hearing loss. The presence of significantly elevated aural-overload thresholds, consistent with the presence of cochlear pathology in regions of normal pure-tone sensitivity, confirmed previous findings obtained with this subject population by other investigators. In addition, a marked reduction in word discrimination was observed in the presence of a background of competing noise.

For experiment II, normal hearers listened to consonant-nucleus-consonant monosyllables filtered to match the mean audiometric configuration of the noise-exposed subjects in experiment I. Results showed significantly better performance with these filtered words by the normally hearing subjects than that by the noise-exposed group for unfiltered materials. The results of the second experiment were interpreted as providing further support for the presence of subtle auditory dysfunction in the mid-frequencies despite normal threshold sensitivity in this same frequency region.

Dans une première expérience, nous avons utilisé des sujets présentant une baisse de l'acuité auditive à la suite de traumatismes sonores. Nous avons tout d'abord cherché a connaiˇtre l'importance de l'atteinte cochléaire au niveau des fréquences moyennes et nous avons déterminé pour cela les seuils de surcharge auditive (test harmonique); comme certains auteurs précédents, nous nous sommes apençus que ces seuils étaient nettement élevés, témoignant d'une atteinte cochléaire dans une région dont la sensibilité aux sons purs était pourtant normale. Nous avons ensuite noté une baisse importante de la discrimination de mots en présence de bruit.

Dans une seconde expérience, nous avons utilisé des sujets à audition normale. Nous leur avons fait écouter des monosyllabes CNC filtrées de façon à se rapprocher de la configuration audiométrique moyenne des sujets précédents. Leur performance pour ces mots filtrés fut bien meilleure que celle des sujets ayant été exposés au bruit pour les mots non filtrés. Cette deuxième expérience nous semble encore meilleure pour mettre en évidence la présence d'un dysfonctionnement de la cochlée au niveau des fréquences moyennes alors que les seuils de sensation sont normaux pour ces měmes fréquences.  相似文献   

4.
Résumé

Les temps de réaction nous offrent une méthode idéale pour mesurer les effets sensoriels très petits. Cette méthode permet aussi à l'opérateur de contrôler le comportement du sujet en situation expérimentale. Nous avons utilisé cette méthode pour étudier les relations entre les temps de réaction et l'intensité d'un son pur en présence d'un autre son de fréquence différente sur la même oreille ou sur l'autre oreille; l'intensité du son masquant pouvaît aussi être modifyée.

Les temps de réaction diminuent d'abord rapidement, puis plus lentement avec l'intensité, mais les courbes se déplacent sur l'axe des abscisses avec le seuil masqué. Aussi la pente des courbes varie avec le seuil masqué de la même façon que celle des courbes de recrutement. L'asymptote des courbes n'est pas en relation simple avec le seuil masqué, mais dépend peut-être de l'intensité totale. Aussi, quand l'intensité des «pips» devient plus grande que celle du son masqué, il y a un changement brusque dans les courbes; on passe peut-être alors d'un effet d'inhibition à un effet de facilitation.  相似文献   

5.
Measurement of the acoustic stapedial reflex parameters has proved to be a useful tool for evaluating the function of the acoustic-facial reflex. However, there is no agreement about the definitions of the parameters; moreover, most of the data have been obtained by manual measurement methods. The authors describe a computerized analytical method which permits the parameters to be measured according to the definitions and methods suggested by others and according to the new analytical method described, which is performed on the basis of the derivative of the stapedial reflex curve. The two methods are compared in 40 normal subjects.

La mesure des paramètres de la courbe de réponse du réflexe stapédien donne des renseignements pour l'évaluation de la fonction du réflexe acoustico-facial. II n'existe pourtant pas d'accord sur la définition des paramètres et la plupart des données ont été relevées manuellement. Dans ce travail les auteurs présentent un systeme d'analyse à l'aide d'un ordinateur qui permet de mesurer les paramètres du réflexe stapédien avec les méthodes généralement employées, d'après les définitions données par d'autres auteurs, et par une nouvelle méthode d'analyse, fondée sur l'étude de la dérivée de la courbe de réponse du réflexe. On décrit la nouvelle méthode d'analyse et on compare les résultats obtenus à l'aide des deux méthodes chez 40 sujets normaux.  相似文献   

6.
The authors studied the remote masking (RM) in patients with Menière's disorder during the hearing loss fluctuations produced either by the disorder or by the glycerol test (Klockhoff). The RM was recorded for pulsed tones of 250, 500 and 1 000 Hz; the masker was a continuous narrow-band noise centered at 3 000 Hz, with 305 Hz (2 875–3 180 Hz) bandwidth, delivered at an overall level of 98 dB SPL. The results showed that the RM decreases during the acute phase, i.e. when the hearing loss increases, and, increases if the glycerol tests do not significantly modify the RM value. They seem to confirm the hypothesis that the RM may be due to a mechanical effect in the internal ear and suggest the possibility of using the RM as a test of end-organ rigidity.

Résumé

Les auteurs ont étudié le RM sur des sujets atteints de maladie de Menière pendant les fluctuations du déficit auditif produites par les crises ou provoquées par le test au glycérol selon Klockhoff. Le RM a été enregistré pour des tons de 250, 500 et 1 000 Hz interrompus deux fois par seconde et d'une durée de 250 ms; le son masquant était un bruit à bande étroite centrée sur la fréquence de 3 000 Hz, d'une largeur de 305 Hz (2 875–3 180 Hz), envoyé en continu à. 98 dB SPL. Les résultats ont montré que la valeur en décibels du RM diminue pendant les crises, lorsque le deficit auditif augmente; au contraire, le RM augmente au moment oú le glycérol produit une amélioration des seuils d'audition. Pour des tests au glycérol négatifs, nous n'avons observé aucune variation marquée du RM. Ces résultats vérifient l'hypothèse de l'origine mécanique du RM et suggèrent la possibilité d'utiliser le RM pour tester la rigidité de la membrane basilaire.  相似文献   

7.
We present the results of a retrospective study of the speech understanding of 52 subjects with surgically confirmed acoustic neurinoma. Subjects were divided into three groups, depending on whether acoustic reflexes were all present, all absent, or present with abnormalities in the pathological ear. Results indicated that the three groups were homogeneous with respect to pure-tone sensitivity and PBmax. Subjects who lacked all acoustic reflexes, however, experienced significantly greater rollover of speech intelligibility at high intensities than did subjects with all or some reflexes intact. A neural-mechanical interaction is suggested as a basis for the rollover phenomenon in subjects with retrocochlear eighth-nerve disorder.

Nous avons effectué une étude rétrospective de l'intelligibilité vocale chez 52 sujets opérés de neurinome du VIII. Les sujets avaient été divisés en trois groupes, selon que, dans l'oreille pathologique, les réflexes acoustiques pour les fréquences 500 à 4 000 Hz étaient tous présents, ou absents pour seulement 1 à 3 fréquences, ou tous absents.

Les réultats montrent que les trois groupes sont homogènes quant à la sensibilité tonale et au maximum d'intelligibilité pour des mots phonètiquement équilibrés (PBmax). Par contre, chez les sujets présentant une absence totale de réflexes acoustiques nous avons noté une distorsion d'intensité de la courbe d'intelligibilité (courbe en cloche) beaucoup plus forte que dans les deux autres catégories de sujets.

Chez les sujets atteints de désordres rétro-cochléaires du VIII et pour que soit provoqué le phénomène de la courbe d'intelligibilité en cloche, nous pensons done qu'il existe une perturbation de l'oreille à la fois neuronale et mécanique.  相似文献   

8.
The test-retest variability of a series of auditory functions has been investigated in a group of severely hearing-impaired and deaf subjects (64 ears, median Fletcher index: 80 dB) and in a group of 10 controls with normal hearing. An adaptive forced-choice procedure was used for both groups. The functions were: tone audiogram, difference limen for intensity, difference limen for frequency, modulation transfer function and critical ratio. In spite of sometimes strongly deviating function values within the hearing-impaired group, the test-retest variability of the two groups was found to be of the same order of magnitude, except for the tone audiogram where the variability in the hearing-impaired group was twice that for the control group.

Nous avons examiné la variabilité des mesures répétées de quelques fonctions auditives dans un groupe de sujets ayant des troubles auditifs importants (64 oreilles; médiane de l'index de Fletcher 80 dB). Par comparaison nous avons aussi examiné un groupe de 10 sujets ayant une audition normale. Dans les deux groupes nous avons utilisé une procédure adaptive et de choix forcé. Nous avons examiné les seuils auditifs, les seuils différentiels d'intensité et de fréquence, la fonction de transfert de modulation et le rapport critique. Malgré les anomalies majeures du groupe des malentendants, la variabilité des mesures dans les deux groupes est équivalente, à l'exception de la variabilité des seuils auditifs qui est deux fois plus grande chez les malentendants.  相似文献   

9.
Résumé

Dans le domaine de l'audition, les essais que nous avons effectués à propos de la direction du son, nous ont amené à formuler quelques constatations:

1. Des tons permanents, měme de basse fréquence (p. ex. 500 Hz), ne donnent aucune ou tout au plus une mauvaise impression de la direction de leur source; uniquement les phénomènes transitoires provoquent l'impression nette d'une direction déterminée.

2. Quand on prolonge un phénomène acoustique qui donne p. ex. une bonne impression de gauche, en le faisant exclusivement dans l'oreille droite et cela pendant 2 msec, cette prolongation n'est pas perceptible par l'oreille.

3. Une excitation de l'oreille gauche à l'aide d'une seule demi-onde du ton 250 Hz, conjointement avec l'excitation de l'oreille droite fut ainsi combinée en une impression sonore commune de hauteur tonale moyenne; il est possible dès lors, en faisant varier la durée d'excitation des deux oreilles, d'arriver à un déplacement de l'impression de direction.

C'est surtout à propos de ce dernier de nos essais que nous avons discutté les phénomènes de nature mécanique se déroulant dans notre oreille interne lors d'un phénomène transitoire.  相似文献   

10.
The aim of the present work was to establish whether contingent negative variation audiometry (CNV-A) is applicable to children. In a group of 23 children aged 5-7 years, only 10 generated clearly recognizable CNV when tested with the method successfully used in adults. When the procedure was modified by prolonging the S1-S2 interval and by introducing attractive slides to serve as the S2 stimulus and by adopting a slower repetition rate, 9 children randomly selected from the former group generated high-amplitude CNV (10.1 ± 4 μV). The CNV-A measurements involving a longer auditory stimulus (S1), lasting nearly to the beginning of S2, and an even slower repetition rate were equally successful in 18 children aged 3-5 years, who generated CNV with an average amplitude of about 9 μV (range 5-15 μV). We believe that the basic problem of successful CNV recording in children is to attract their attention to the signals of the CNV paradigm. The child's attentiveness decreases rapidly. The mean difference and the absolute mean difference between the subjective hearing threshold for white noise and the perception threshold for white noise as determined by CNV-A were as follows: 8.8 ± 8 dB (both values) for the older group, and 3 ± 10.4 and 8.6 ± 6.5 dB, respectively, for the younger group. These differences are quite comparable to those obtained in adults. We therefore believe that CNV-A, used in combination with the behavioral method, provides a most reliable estimate of the child's hearing threshold in dubious situations.

Le but de ce travail était l'étude de l'audiométrie à variation contingente négative (A-VCN) chez l'enfant. Avec la méthode A-VCN habituellement utilisée chez l'adulte, nous n'avons obtenu de réponse nette que chez 10 enfants sur 23 aˇgés de 5 à 7 ans. En modifiant la méthode (en prolongeant l'intervalle S1-S2, en introduisant des diapositives intéressantes en tant que S2 et en ralentissant le rythme de répétition), chez 9 enfants sélectionnés au hasard, tous ont présenté des réponses VCN de grande amplitude (10,1 ±4 μV). Dans un groupe de 18 enfants plus jeunes (entre 3 et 5 ans), la méthode utilisant des stimulations auditives (S1) prolongées presque jusqu'au début de S2 à un rythme de répétition plus lent a également fourni des réponses VCN d'amplitude moyenne d'environ 9 μV (5-15 μV). Nous croyons que la question essentielle pour obtenir des réponses VCN nettes est celle du paradigme de stimulation. La réponse décroiˇt d'habitude rapidement; ainsi ne peut-on moyenner qu'une douzaine de réponses entre 5 et 7 ans, seulement environ 9 entre 3 et 5 ans. La différence moyenne et la différence moyenne absolue entre le seuil subjectif d'audition du bruit blanc et le seuil de perception du bruit blanc déterminé par l'A-VCN ont été les suivantes: 8,8 ± 8 dB (pour les deux) dans le groupe plus aˇgé et 3 ± 10,4 dB et 8,6 ± 6,5 dB, respectivement, dans le groupe le plus jeune. Ces différences sont comparables à celles relevées chez les adultes. En conséquence, nous pensons que l'A-VCN, utilisée en combinaison avec les méthodes comportementales, fournit l'estimation la plus fiable des seuils auditifs des enfants dans les cas douteux.  相似文献   

11.
Two-tone masking of 1 000-Hz signals was investigated in 5 normally-hearing listeners. The results indicate a consistent increase in critical bandwidth with level of the two masking tones (approximately 3%/dB). Irregularities in the individual two-tone masking functions led to further investigations with a single listener. For subcritical frequency separations between masking tones, -10 dB/decade masking slopes were demonstrated along with large dips or notches in the two-tone masking functions. Both the -10 dB/decade masking slopes and the large notches were replicated in detail when only the lower-frequency tones of the two-tone masking pairs were employed as maskers. Separate masking bands were then introduced that eliminated the -10 dB/decade masking slope and the large notch. It is concluded that the two-tone masking experiment is really a single-tone experiment, and that the detection of beats, roughness, and combination tones determines the form of single-tone and two-tone masking functions. If critical bandwidth estimates are to be obtained from these experiments, it is most appropriate to refer to those estimates as ‘critical bandwidths for tonal interaction’.

Etudiant chez cinq personnes à audition normale l'effet de masque produit par deux sons sur un signal de 1 000 Hz, nous avons pu observer, en augmentant le niveau des deux sons masquants, un accroissement consécutif de la largeur de la bande critique (environ 3%/dB).

Des irrégularités dans les fonctions individuelles de masque par les deux sons nous ont conduit à poursuivre nos observations sur seulement un sujet. Utilisant des séparations fréquentielles sub-critiques entre les sons masquants, nous avons noté dans les fonctions de masque par les deux sons, d'une part une pente de -10 dB/décade et d'autre part d'importantes encoches; nous avons fait la měme observation avec comme masque seulement les sons inférieurs. Des bandes de masque séparées furent alors ajoutées et la pente de -10 dB/décade ainsi que les grandes encoches disparurent.

En conclusion, nous pensons que les expériences de masque par deux sons sont en réalité des expériences par un seul son, et que la détection des battements, de la rugosité et des sons combines détermine la forme des fonctions de masque par un son et par deux sons. Si ces expériences doivent nous donner une estimation de la largeur de la bande critique, il nous paraiˇt plus logique de parler à leur propos d'estimation de la largeur des bandes critiques sans interaction tonale.  相似文献   

12.
Phonetically balanced word lists were mechanically coupled onto the ossicular chain of anesthetized guinea pigs by piezoelectric-type drivers and the resulting cochlear microphonic (CM) recorded on magnetic tape. Similar recordings of the CM resulting from free field tympanic membrane stimulation by hi-fi speakers were also obtained. The recordings were compared by conventional discrimination testing. In discrimination testing of all the raw recordings, listeners achieved essentially perfect scores. Addition of masking noise sufficient to reduce mean discrimination scores to 65-70% revealed no significant discrimination differences. When piezoelectrically initiated, CM-derived lists were compared with similar lists passed through hearing aids in an anechoic chamber, the preference of a panel of listeners for the quality of mechanically coupled speech was significantly higher. Mechanical-acoustical displacement equivalency at normal physiological levels and freedom from mechanical-electrical artifact were demonstrated by measurement of ossicular chain displacement by a fiber optic lever displacement transducer.

Nous avons étudié les paramètres de la fidélite de reproduction de la parole (listes de mots phonétiquement équilibrés) couplée électro-mécaniquement (coupleur piézo-électrique) au niveau de la chaiˇne ossiculaire du cobaye. Examinant tout d'abord avec un appareil à fibre optique les déplacements de la chaiˇne ossiculaire du cobaye nécessaires au maintien d'un niveau donné (normal physiologiquement, dans la bande des fréquences audibles) du potentiel microphonique, nous avons pu noter, en utilisant un coupleur électro-mécanique, l'équivalence du phénomène avec celui observé en utilisant un coupleur électro-acoustique HiFi, ainsi que l'absence d'artéfacts électro-mécaniques. Les deux sortes d'enregistrement sur bande magnétique des potentiels microphoniques du cobaye (au niveau du ler tour de la cochlée et à partir d'une stimulation, soit électro-mécanique, soit électro-acoustique), nous ont permis de rechercher chez l'homme la discrimination standard ainsi que dans le masking; nous n'avons observé aucune différence dans les résultats. Comparant la discrimination obtenue: - à partir de listes de mots enregistrés sur bande à travers l'oreille du cobaye stimulée électro-mécaniquement - et à partir des měmes listes enregistrées en chambre anéchoïque après passage au travers d'une prothèse acoustique conventionnelle, nous avons pu noter une nette préférence des observateurs pour la qualité des enregistrements obtenus à partir de la stimulation électro-mécanique.  相似文献   

13.
After a discussion of possible methods for measuring the hearing of infants, we present a more appropriate method which we have developed and used over a number of years. The method applied is called ‘sound orientation audiometry’ and is based on the readiness of infants to seek out the sources of sounds. As the infants are observed by means of a one-way mirror, no distraction is possible. In the light of our experience, the proof of intentional application is most favorable when the infants are 5-6 months or 3-4 years old. The application threshold is at 40-50 dB SPL. The results gained by this measuring method are compared with sound threshold audiometric results gained 4-9 years after the first examination. Judging from the evaluation, we can see a good correlation of the measuring results obtained by sound orientation audiometry during the first examination with audiometric hearing loss values determined later. The correlation coefficient of the group examined is r = 0.77. The procedure is being discussed as to its value and is considered especially valuable because the whole auditory apparatus as far as the central auditory center is under control. This method is clinically appropriate without much expenditure and may be applied at any time.

Parmi les méthodes d'audiométrie du jeune enfant, le test COR de Suzuki est bien connu, mais présente, à notre avis, quelques inconvénients. Nous lui avons substitué un test d'orientation un peu différent: l'enfant est laissé seul dans un pare et ses réactions à divers stimuli sonores lui parvenant par des haut-parleurs placés aux quatre coins de la pièce insonorisée sont observées à travers une glace sans tain. Le seuil d'audition se situe autour de 40-50 dB SPL. 4-9 ans plus tard nous avons examine un certain nombre d'en-fants par audicmetrie standard et avons obtenu un coefficient de corrélation de 0,77 entre les deux tests. Notre méthode, certes, ne peut être appliquée qu' à des enfants men-talement normaux, mais, grâce à elle, c'est l'ensemble de la fonction auditive que nous pouvons apprécier de façon satisfaisante.  相似文献   

14.
Audi News     
Résumé

Nous avons mesuré la diplacausie en présentant alternativement aux deux oreilles les pulsations d'un son pur. La fréquence dans I'oreille droite (référence) est ajustée qusqu'à ce que la hauteur du ton dans cette oreille soit la měme que la hauteur du ton dans I'oreille gauche (oreille expérimentelle). Les sujets les plus intéressants sont ceux qui sont sourds d'une oreille. Comme de tels sujets sont rares, nous avons provoqué une fatigue passagère de I'ouie en donnant périodiquement des pulsations bruyantes d'un son pur. La diplacausie est mesurée après avoir donné ce ton masquant suivant le schéma (fig. 1).

La figure 2 indique les résultats: verticalement le changement relatif en %, horizontalement la fréquence du ton expérimental.

Nous avons mesuré le changement du ton du résidu dans les měmes conditions. Le résidu était composé au moyen d'un signal d'amplitude modulée. Les composants de ce signal coïncidaient avec trois maxima successifs ou trois minima successifs de la figure 2. Le signe du changement de ton d'un résidu et le signe du changement de ton de ses composants se trouvaient identiques.

Les résultas indiquent que le résidu est capté à des endroits sur la membrane basilaire oú précisément ses composants sont captés.  相似文献   

15.
The amount of temporary threshold shift (TTS) measured in a particular individual is dependent on several factors. One such factor is the pre-exposure hearing level of the subject. In this study, the contribution of this factor to the measured TTS was examined in 8 normal-hearing subjects. TTS measurements were made in unmasked and masked conditions following a 4-hour exposure to noise. The masked condition was designed to simulate a flat mild hearing loss. Results indicated that TTS observed under conditions of broad-band masking was reduced as compared to TTS for the unmasked condition. The results, moreover, were consistent with the predictions of a model developed previously from earlier research with narrow-band maskers.

L'importance du glissement temporaire du seuil (TTS) dépend de plusieurs facteurs parmi lesquels nous avons retenu le niveau d'audition avant exposition. Nous avons effectué sur 8 sujets normaux des mesures de TTS après 4 h d'exposition à un bruit de restaurant en présence et en l'absence d'un bruit masquant continu. Les résultats montrent que le TTS était plus bas en présence de bruit masquant (simulant une perte d'audition plate légère) qu'en son absence. Nos résultats coïncident avec les prévisions que nous avions faites sur la base d'un modèle réalisé précédemment avec des masquages à bande étroite.  相似文献   

16.
In man, the scalp-recorded 'Frequency-following response' (FFR) can be well observed only at fairly high levels of stimulation. As a consequence, it is difficult to ascertain whether the low or the high-frequency channels of the peripheral auditory system mediate this response. It is shown that the sensitivity of the recording method is considerably increased when the averaged recorded waveform is subjected to frequency analysis. Results from experiments with high-pass masking noise become unequivocal and they suggest that the low-level FFR is caused by nervous activity arising in the apical part of the cochlea and mediated by the low-frequency channels in the brain stem.

Résumé

Les réponses évoquées par le tronc cérébral à la stimulation acoustique par des tons de basse fréquence (500 Hz) ont une courbe d'onde qui ressemble beaucoup à celle du stimulus. Pour un ton assez long, la réponse moyennée (FFR) est presque sinusoïdale. On peut améliorer la sensibilité de la méthode d'enregistrement en effectuant une analyse de Fourier de la réponse moyennée. Avec cette méthode Sensibilisée il est possible d'obtenir des enregistrements satisfaisants pour des stimuli faibles (45-60 dB SPL). Le problème central de l'origine du FFR est le suivant: pour des stimuli acoustiques assez forts, il est absolument incertain que la réponse résulte des canaux des voies auditives pour les basses ou les hautes fréquences. Avec la méthode sensibilisée, il est facile de résoudre ce problème: en appliquant un bruit masquant la région des hautes fréquences (1 000 Hz et plus) on pourra observer que la réponse FFR ne disparaiˇt pas. On peut en conclure que la réponse FFR à un stimulus faible est vraiment une réponse évoquée par les canaux pour les basses fréquences des voies auditives. Pour l'usage du FFR en clinique, il est recommandé d'utiliser la měme méthode afin d'éviter une contamination par des réponses dues aux canaux pour hautes fréquences.  相似文献   

17.
Numerical data from the literature on presbyacusis, in the form of pure-tone hearing threshold levels as a function of age, are subjected to critical evaluation and analysis. A formula is derived for predicting the age effect for otologically screened groups of males and females. Further, the complete distribution of hearing levels for each audio-metric frequency in the range 0.125-12 kHz and at any age can be estimated with the aid of tabulated coefficients and some simple rules. The study was undertaken in connection with the work of ISO on standardization of normative audiometric data.

Nous avons passé en revue et soumis à une analyse critique les données numériques apportées par divers travaux publiés sur la presbyacousie, et relatives aux niveaux du seuil d'audition pour les sons purs en fonction de l'aˇge. Nous avons obtenu une formule permettant de prédire l'effet de l'aˇge pour des groupes de sujets masculins et féminins otologiquement normaux. De plus, graˇce à un tableau de coefficients et à l'aide de quelques règies simples, il nous est apparu possible d'estimer les niveaux liminaires d'audition pour chaque fréquence audiométrique, dans la gamme de 0,125-12 kHz, pour un aˇge quelconque. L'étude a été entreprise en liaison avec le travail de l'ISO concernant la normalisation des données audiométriques.  相似文献   

18.
The modified Pohlman sound probe was used to provide a prognostic evaluation of the results of surgery in otospongiosis by means of transtympanic exploration. Based on the reactions obtained with this probe, it is possible to recognize theoretically the degree of cochlear involvement ‘direct bone conduction coefficient’ and to indicate which component of the hearing defect - conductive or perceptive - prevails in a given case of otospongiosis.

Sur la base de travaux antérieurs concernant la conduction osseuse et la mise en ?uvre de la sonde de Pohlman, nous avons élaboré une méthode d'observation de la conduction osseuse directe dans l'otospongiose. Les mesures peuvent ětre faites à l'aide d'une tympanoponction ou tympanotomie pendant la stapédectomie. Nous avons constaté que les résultats obtenus à l'aide de la sonde peuvent constituer une indication sur les résultats probables d'une stapédectomie. Cette méthode permet théroriquement de prévoir si chez le malade il y a une prépondérance de transmission ou de perception.  相似文献   

19.
Among 149 children (median age 23 months, range 2–123 months) examined by ECochG, a comparison was made between pure-tone and ECochG thresholds in 53 patients. By using linear regression analysis a high correlation was found (correlation coefficient 0.92, p< 0.0005) proving that ECochG gives valid estimates of the hearing thresholds, also in small children. A comparison between behavioral observation audiometry (BOA) and ECochG thresholds was performed in 62 children. It was concluded that BOA exhibits poor sensitivity in the assessment of hearing losses and underestimates their degree of severity. Furthermore, when BOA diagnoses normal hearing, there is a 9% risk of depriving a ‘deaf child of suitable treatment’.

Parmi 149 enfants, ayant entre 2 et 123 mois (âge moyen: 23 mois), que nous avons examines entre 1969 et 1979, nous avons pu effectuer chez 53 une comparaison des seuils en son pur et en ECochG. Par analyse de régression linéaire, nous avons trouvé une haute corrélation (coefficient de corrélation 0,92; p < 0,0005) ce qui nous amène à penser que l'ECochG est une méthode valable pour l'estimation des seuils auditifs chez les petits enfants.

Chez 62 enfants, nous avons comparé l'audiométrie de comportement (AC) et les seuils estimés en ECochG. Nous avons pu observer que l'AC présente une faible sensibilité dans l'évaluation de la perte auditive; elle sous-estime tout particulierement les pertes d'audition graves; ce qui nous conduit à établir à 9% le risque de priver un enfant sourd d'un traitement convenable lorsque l'AC fait apparaiˇtre une audition normale.  相似文献   

20.
In order to supplement our previous report on the reliability and validity of slow vertex response (SVR) audiometry, the detectability of the response, the agreement among scorers and test-retest reliability were studied in 6 children aged 2-4 years who have sensorineural hearing loss of 60-75 dB for the test frequency (1 000 Hz). Mean percentage of positive response increased from 20.6 to 62.2% as stimulus intensity was increased from 60 to 80 dB. Such a sharp increase in the detectability of the response at a level of stimulus intensity close to the auditory threshold of the subjects was not observed in normal children. The results indicate that SVR audiometry is more reliable and valid in children with sensorineural hearing loss than in normal children.

En complément de notre étude sur des enfants à audition normale et concernant les jugements des tracés des potentiels lents, nous avons cette fois procédé aux měmes contrO'les de jugement mais à propos de tracés effectués chez 6 enfants de 2 à 4 ans et ayant une atteinte sensori-neurale de 60 à 75 dB pour le 1 kHz (fréquence test). Contrairement à ce que nous avons noté sur des enfants à audition normale, nous avons pu observer un très rapide accroissement de la détectabilité des tracés positifs (20,6-62,2%) pour des intensités allant du seuil à 20 dB au-dessus. L'étude des potentiels lents chez les enfants à atteinte sensori-neurale nous paraiˇt done un procédé très valable en clinique.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号