首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 118 毫秒
1.
目的比较钢板内固定与外固定架治疗桡骨远端C型骨折术后的治疗效果。方法选择C型桡骨远端骨折患者61例,将其分为内固定组与外固定组。其中,内固定组32例,男15例,女17例,年龄22~67岁,平均(42.30±3.10)岁;按AO分型:C1型12例,C2型17例,C3型3例。外固定组29例,男13例,女16例;年龄24~66岁,平均(41.53±3.70)岁;按AO分型:C1型11例,C2型14例,C3型4例。采用腕关节活动度、X线片测量指标及GARTLAND-WERLEY评分进行综合评定。结果所有患者均获得随访,内固定组随访时间为12~30个月,平均(22.1±1.5)个月;外固定组12~36个月,平均(25.3±2.0)个月。X线片均显示两组骨折全部愈合。两组患者尺偏角、桡骨高度、腕关节背伸、掌屈、尺偏、桡偏、旋前、旋后等腕关节活动度及GARTLAND-WERLEY评分均无明显差异,比较差异无统计学意义(P>0.05)。但内固定组掌倾角(12.05±3.01)°明显优于外固定组(7.05±2.90)°,比较差异具有统计学意义(t=6.377,P<0.05)。内固定组并发症发生率(9.4%)明显小于外固定组(24.1%),比较差异具有统计学意义(χ2=7.580,P=0.006)。钢板内固定组伤口感染2例,正中神经损伤1例;外固定组钉道感染3例,固定松动2例,碗关节僵硬2例。结论钢板内固定与外固定架治疗桡骨远端骨折均可取得满意的疗效,钢板内固定固定可靠,未发生固定松弛现象,临床上可根据患者实际情况选择手术方式。  相似文献   

2.
《皖南医学院学报》2019,(2):146-148
目的:探讨掌侧加压锁定钢板结合外固定架治疗易移位C3型桡骨远端骨折的疗效。方法:2012年6月~2014年6月,采用掌侧加压锁定钢板结合外固定架治疗易移位C3型桡骨远端骨折11例。其中男5例,女6例;年龄25~74岁,平均(55.5±10.2)岁。术后3~6周去除外固定架,随访记录骨折愈合时间及掌倾角、尺偏角、桡骨高度及腕关节活动情况。末次随访时根据改良的Gartland-Werley评分标准评定疗效。结果:11例均获随访,随访时间12~24个月,平均(16.0±3.6)个月。术后切口均Ⅰ期愈合,无伤口或钉道感染及皮肤坏死等早期并发症,但有1例病人出现切口周围复杂性局部疼痛综合征(CRPS)。X线片复查示骨折均愈合,愈合时间8~12周,平均(10.3±1.3)周;末次随访无骨折移位,关节面轮廓良好、无塌陷,桡骨未见明显短缩等。掌倾角6~15°,平均(10.4±4.3)°;尺偏角18~25°,平均(20.8±4.2)°。腕关节背伸、屈曲、桡偏、尺偏、旋前、旋后功能良好。根据改良的Gartland and Werley评分标准评价腕关节功能,获优5例,良4例,一般2例,优良率为82%。结论:对于易移位C3型桡骨远端骨折,掌侧加压锁定钢板结合外固定架可较好维持骨折复位,可获良好的腕关节功能。  相似文献   

3.
桡骨远端骨折是人类全身最常见的骨折,其发病率约占急诊骨折病人的17%,治疗不当会产生明显的功能受限.红河州滇南中心医院骨科2009年10月至2012年6月应用掌侧锁定加压钢板治疗桡骨远端C型骨折共32例,总体效果良好,现报告如下.  相似文献   

4.
张施展  张卫国  余毅  汪阳  蒋林 《广东医学》2016,(17):2634-2636
目的:比较切开复位钢板内固定和外固定架固定治疗C型老年桡骨远端骨折的临床疗效。方法回顾性分析C型老年桡骨远端骨折患者77例,分别采用掌侧切开复位锁定钢板内固定治疗42例,外固定架固定治疗35例。根据Stewart等改良的Sarmiento评分标准及Gartland-Werley功能评分标准分别行影像学及腕关节功能评估,对结果进行统计学分析并比较两组的治疗效果。结果所有病例均在门诊获得随访,随访时间13~34个月。骨折愈合时间为12~20周。根据Stewart等改良的Sarmiento评分标准,分别比较两组患者在术后即刻、术后6周、3个月、6个月及末次随访时的影像学指标,钢板内固定组优于外固定架组,差异有统计学意义( P<0.05)。末次随访时钢板内固定组Gartland-Werley功能评分优28例,良9例,可5例,优良率88.1%;外固定架组优19例,良11例,可5例,优良率85.7%,两组比较差异无统计学意义( P>0.05)。钢板内固定组创伤性关节炎1例,正中神经刺激1例;外固定架组创伤性关节炎1例,钉道感染3例,螺钉松动2例。结论钢板内固定与外固定架固定治疗C型老年桡骨远端骨折均可获得满意的疗效,但与外固定架相比,钢板内固定骨折对位更好,术后复位丢失少,术后早期功能恢复良好,患者满意度高。  相似文献   

5.
目的:观察外固定支架与锁定钢板内固定治疗桡骨远端C型骨折患者的疗效。方法:选择C型骨折患者66例,采用随机数表法分为A组和B组,每组各33例。A组患者给予外固定支架治疗;B组患者给予锁定钢板内固定治疗;比较两组患者的术中出血量,手术、住院和骨折愈合时间。根据手术疗效评价为优、良、可、差。结果:A组患者术中出血量、手术时间、住院时间和骨折愈合时间与B组比较差异有统计学意义(P<0.05);两组患者优良率比较差异无统计学意义(P>0.05)。结论:外固定支架治疗桡骨远端C型骨折患者比锁定钢板内固定治疗出血量少、手术时间与住院时间短,骨折愈合快。  相似文献   

6.
掌侧锁定加压钢板治疗桡骨远端C型骨折   总被引:1,自引:0,他引:1  
目的 探讨锁定加压钢板(LCP)内固定治疗桡骨远端AO分型C型骨折的初期疗效.方法 总结从2007年1月~2009年1月应用锁定加压钢板(LCP)内固定治疗桡骨远端C型闭合性骨折26例.手术采用掌侧入路,复位后于掌侧置入LCP钢板,在C型臂X线机透视下检查桡骨长度、桡骨关节面、掌倾角及尺偏角复位情况,满意后置入锁定螺钉,对于严重骨缺损者应予植骨.术后第1天开始被动活动腕关节,1周后主动活动,功能锻炼.结果 全部获得随访,平均11个月(8~21个月).X线显示骨折全部Ⅰ期愈合,平均愈合时间为8周,所有病例均无感染、骨不连、钢板松动、腕管综合征、正中神经炎等并发症.按改良的Mcbride腕关节功能评价标准:优18例,良6例,可2例,优良率为92.31%.结论 坚强内固定下早期进行腕关节功能锻炼是治疗粉碎及不稳定桡骨远端骨折的有效措施,使用锁定加压钢板(LCP)内固定治疗桡骨远端C型骨折具有复位满意、固定坚强、可早期进行功能锻炼、关节功能恢复优良等优点.  相似文献   

7.
目的 探讨桡骨远端不稳定性骨折锁定加压钢板固定治疗的临床疗效.方法 自2006年7月至2007年12月采用国产锁定接骨板内固定治疗桡骨远端不稳定骨折35例1,并进行随访.结果 2006年7月至2007年12月采用国产锁定接骨板治疗桡骨远端不稳定骨折35例.3-6个月骨折愈合.根据Dienst评分系统综合评分,优25例,良8例,可2例,优良率94.3%.结论 锁定加压钢板内固定治疗桡骨远端不稳定骨折固定牢固,腕关节能早期功能锻炼.  相似文献   

8.
《中国医学创新》2015,(20):141-143
目的:比较外固定架结合克氏针与锁定钢板内固定治疗桡骨远端C型骨折的临床疗效。方法:选取2007年2月-2014年1月在本院接受治疗的38例C型桡骨远端骨折患者作为研究对象,按照手术方案不同分为A组(采用外固定架结合克氏针固定)与B组(采用掌侧入路切开复位、锁定钢板内固定)。两组患者骨折的AO分型:A组21例,其中C1型5例、C2型8例、C3型8例;B组17例,其中C1型5例、C2型5例、C3型7例。术后定期复查X线片,骨折愈合后对腕关节的功能进行Dienst评分。结果:随访时间为4~13个月,平均8.6个月,骨折愈合时间为3~8个月,平均5.3个月。A组有2例发生针道感染,2例出现克氏针松动、退针。B组2例发生骨折复位后丢失、螺钉进入关节腔。A、B组的C1、C2型骨折间的优良率差异无统计学意义(P>0.05),C3型骨折A组优于B组(P<0.05)。结论:对于闭合性桡骨远端C1、C2型骨折,可选择外固定架结合克氏针固定或锁定钢板内固定术,而对于C3型骨折,选择外固定架结合克氏针固定术疗效相对较佳。  相似文献   

9.
目的 研究锁定加压铜板治疗桡骨远端C3型骨折的临床疗效.方法 采用掌侧入路24例,背侧入路9例,掌背侧联合入路7例,均采用桡骨远端锁定加压钢板固定.结果 术后随访8~16个月,经X线片证实40例骨折全部愈合,按照Dienst功能评估标准,优17例,良21例,可2例,优良率95.0%.结论 桡骨远瑞锁定加压钢板对桡骨远端C3型骨折坚强固定,术后可早期进行功能锻炼,有利于腕关节功能恢复,疗效满意.  相似文献   

10.
闫小龙 《当代医学》2016,(28):89-90
目的:探讨外固定支架与锁定钢板内固定治疗桡骨远端C型骨折临床疗效及安全性差异。方法研究对象选取桡骨远端C型骨折患者80例,以随机数字表法分为A组和B组,各40例,分别采用掌侧锁定加压钢板内固定和外固定支架治疗;比较2组患者Cooney腕关节评分优良率,随访尺偏角、掌倾角、桡骨高度及术后并发症发生率等。结果 B组患者Cooney腕关节功能优良率显著高于A组(P<0.05);B组患者随访尺偏角、掌倾角及桡骨高度均显著高于A组(P<0.05);同时2组患者术后并发症发生率比较差异无统计学意义。结论外固定支架治疗桡骨远端C型骨折能够显著改善术后腕关节功能,提高关节活动度,且未诱发严重术后并发症出现,疗效优于锁定钢板内固定。  相似文献   

11.
目的探讨桡骨远端T型锁定接骨板治疗桡骨远端不稳定性骨折的临床效果。方法 60例桡骨远端不稳定性骨折患者分为观察组和对照组,每组30例。观察组患者给予桡骨远端T型锁定接骨板治疗,对照组患者给予外固定支架治疗,术后随访3个月,对患者行X线片检查,测量并记录2组患者的骨性愈合时间、掌倾角、尺偏角及腕关节活动度。结果 2组患者骨性愈合时间、掌倾角及尺偏角比较差异均无统计学意义(P>0.05)。观察组患者背伸、掌屈活动显著优于对照组,桡偏显著轻于对照组,差异均有统计学意义(P<0.05)。2组患者尺偏、旋前、旋后情况比较差异均无统计学意义(P>0.05)。观察组和对照组患者治疗效果优良率分别为90.0%和70.0%,观察组患者优良率高于对照组,差异有统计学意义(P<0.05)。观察组和对照组患者并发症发生率分别为6.7%和10.0%,2组患者并发症发生率比较差异无统计学意义(P>0.05)。结论应用桡骨远端T型锁定接骨板治疗桡骨远端不稳定性骨折对桡骨远端的骨性及腱鞘结构的影响较小,手术操作较为方便,可保持背侧软组织的完整性,复位效果好,固定可靠,疗效满意,且并发症少。  相似文献   

12.
探讨掌侧入路锁定钢板治疗桡骨远端不稳定骨折的疗效。方法选择2012 年1 月-2015 年1 月该院收治的93 例桡骨远端不稳定骨折患者,随机分为对照组47 例和观察组46 例。对照组采取外固定支架手术方法,观察组采取掌侧入路锁定钢板内固定治疗,根据患者一般情况、术后的影像学测量参数和Gartland-Werley 腕关节评分评估手术效果。结果两组患者的尺偏角、掌倾角、桡骨短缩和桡腕关节面移位差异均无统计学意义( p>0.05),根据Gartland-Werley 评分标准,对照组优良率为70.2%(33/47),观察组优良率为 89.1%(41/46),经χ2 检验,差异有统计学意义(χ2=5.126, =0.016),优良率观察组> 对照组( p<0.05)。结论经掌侧入路锁定钢板内固定治疗桡骨远端不稳定骨折,患者的术后功能恢复较好,值得临床推广与应用。  相似文献   

13.
目的:探讨锁定钢板治疗桡骨远端粉碎性骨折的疗效。方法:对我院52例桡骨远端粉碎性骨折切开复位锁定钢板内固定术进行回顾。结果:按Dinest标准评估优良率为92.3%。结论:锁定钢板治疗桡骨远端粉碎性骨折,术后腕关节功能恢复较好,是治疗桡骨远端粉碎性骨折的较好方法。  相似文献   

14.

Background

Open reduction and internal fixation using an interlocking plate system has gained popularity for the treatment of dorsally displaced distal radius fractures.

Purpose

To evaluate the functional and radiological results of treating unstable distal radius fractures with the volar locking plate.

Patients and methods

A retrospective review was conducted of patients from one institution using the volar locking plate to treat intra-articular and extra-articular distal radius fractures. Unstable distal radius fractures in 15 patients, comprising 3 men and 12 women with a mean age of 64.4 years (34–76 years), were treated with a volar locking compression plate (Acu-Loc distal radius plate system; Acumed, Oregon, USA) and followed up for a minimum of 1 year. Fractures were classified using the AO classification. Radiographic parameters of preoperative, postoperative, and final follow-up radiographs were compared. The time to initiation of active range of motion was determined. Final follow-up range of motion and complications were reported.

Results

At final functional assessment, the scores of 5 patients were excellent, 7 patients good, and 3 patients fair according to Cooney''s Clinical Scoring Chart. No non-union or infection occurred. Rupture of the flexor pollicis longus tendon occurred in 1 patient.

Conclusion

Treatment of unstable distal radius fractures with a volar locking plate leads to satisfactory results, provided the operative technique is carefully performed to prevent complications.  相似文献   

15.
Abstract

Background. Open reduction and internal fixation using an interlocking plate system has gained popularity for the treatment of dorsally displaced distal radius fractures.

Purpose. To evaluate the functional and radiological results of treating unstable distal radius fractures with the volar locking plate.

Patients and methods. A retrospective review was conducted of patients from one institution using the volar locking plate to treat intra-articular and extra-articular distal radius fractures. Unstable distal radius fractures in 15 patients, comprising 3 men and 12 women with a mean age of 64.4 years (34–76 years), were treated with a volar locking compression plate (Acu-Loc distal radius plate system; Acumed, Oregon, USA) and followed up for a minimum of 1 year. Fractures were classified using the AO classification. Radiographic parameters of preoperative, postoperative, and final follow-up radiographs were compared. The time to initiation of active range of motion was determined. Final follow-up range of motion and complications were reported.

Results. At final functional assessment, the scores of 5 patients were excellent, 7 patients good, and 3 patients fair according to Cooney's Clinical Scoring Chart. No non-union or infection occurred. Rupture of the flexor pollicis longus tendon occurred in 1 patient.

Conclusion. Treatment of unstable distal radius fractures with a volar locking plate leads to satisfactory results, provided the operative technique is carefully performed to prevent complications.  相似文献   

16.
Background With a type C3 distal radius fracture it is extremely difficult to maintain the reduction and to restore congruity of the articular surface because the support for the volar and dorsal bone cortex has been lost. An external fixator crossing wrist in combination with Kirschner wire (K-wire) fixation was popularly used by most studies in recent years. But loss of reduction often occurred especially in the volar sides. Methods A total of 30 cases of type C3 distal radius fracture were treated by a volar buttress plate combined with a transarticular external fixator and other techniques such as K-wire fixation and bone grafting if necessary. The postoperative volar tilt angles, ulnar inclinations, radial heights, range of motion, grip strength and complications were recorded to assess the therapeutic effects. Results Of the 30 patients, 27 patients were followed up for 12-29 (mean 18) months and all fractures healed in 8-13 weeks after surgery (mean 10 weeks). The wrist function was excellent in 8 cases, good in 16 cases and fair in 3 cases according to the Sarmiento scoring system (modified by Stewart). Conclusions For type C3 comminuted fracture with severe volar and dorsal instability, fixation by volar buttress plate combined with transarticular external fixator should be adopted. Dorsal instability could be further stabilized by other techniques such as Kirschner wire fixation, and bone grafting.  相似文献   

17.
目的:观察锁定加压钢板治疗股骨转子间骨折的疗效.方法:应用锁定加压钢板治疗股骨转子间骨折21例.结果:21例患者3~ 6个月骨折均愈合,未出现断钉、内固定松动等并发症,无明显髋内翻和下肢短缩畸形;Harris评分为优11例,良8例,可2例.结论:锁定加压钢板治疗股骨转子间骨折具有容易安装、固定可靠、手术时间短、出血量少、髋关节功能恢复优良率高等特点,是一种有效的手术方法.  相似文献   

18.
目的: 探讨应用锁定加压接骨板(locking compression plate,LCP)治疗桡骨远端骨折的临床疗效。方法: 对17例桡骨远端骨折行切开复位LCP内固定,术后早期功能锻炼。结果: 术后随访7~15个月,所有患者均获得骨性愈合。按照Dinest评估标准,优14例,良2例,优良率达94%。1例发生并发症。结论: LCP治疗桡骨远端骨折疗效满意,尤其适合于不稳定型以及骨质疏松性桡骨远端骨折,能够牢固维持复位,有利于早期功能锻炼。  相似文献   

19.
目的比较锁定钢板与解剖型钢板治疗股骨远端骨折的疗效。方法选取我院2006年3月~2010年5月收治的98例股骨远端骨折患者,随机分为A组(锁定钢板内固定,48例)和B组(解剖型钢板内固定,50例),比较两组的治疗效果。结果两组患者手术时间、手术成功率差异不大,但出血量、住院时间、术后并发症及膝关节功能评分存在明显差异,且具有统计学意义(P〈0.01)。结论锁定钢板内固定治疗股骨远端骨折具有更好的安全性、有效性和微创性,值得推广应用。  相似文献   

20.
邬玉明 《海南医学院学报》2012,18(9):1285-1287,1290
目的:比较锁定钢板与解剖型钢板治疗股骨远端骨折的临床效果及安全性。方法:选取2005年3月~2009年5月收治的115例股骨远端骨折患者作为研究对象,按照内固定方法不同分为A组(锁定钢板)55例和B组(解剖型钢板)60例,比较两组患者手术时间、术中出血量、术后并发症、术后膝关节功能评分等情况。结果:两组患者手术时间比较无统计学差异(P>0.05),术中出血量、骨折愈合时间、术后住院时间、术后并发症比较有统计学差异(P<0.01)。随访观察12个月,按照Kolmert膝关节功能评分标准,A组优32例,良19例,可3例,差1例,优良率为92.7%;B组优28例,良21例,可9例,差2例,优良率为81.7%。两组患者膝关节功能优良率比较有统计学差异(P<0.01)。结论:锁定钢板内固定治疗股骨远端骨折较解剖型钢板更加适合,其具有创伤小、术后恢复快、并发症少、膝关节功能恢复好等优点,值得推广应用。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号