首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 62 毫秒
1.
ObjectivesThis study investigated the impact of final kissing ballooning (FKB) after main vessel (MV) stenting on outcomes in patients with coronary bifurcation lesions after application of the 1-stent technique.BackgroundAlthough FKB has been established as the standard method for bifurcation lesions treated with a 2-stent strategy, its efficacy in a 1-stent approach is highly controversial.MethodsThis study enrolled 1,901 patients with a bifurcation lesion with a side branch diameter ≥2.3 mm, treated solely with the 1-stent technique using a drug-eluting stent from 18 centers in Korea between January 1, 2003 and December 31, 2009. The primary outcome was major adverse cardiac events (MACE)—cardiac death, myocardial infarction, or target lesion revascularization. Propensity score-matching analysis was also performed.ResultsFKB was performed in 620 patients and the post minimal lumen diameter of the MV and side branch was larger in the FKB group than in the non-FKB group. During follow-up (median 36 months), the incidence of MACE (adjusted hazard ratio [HR]: 0.68, 95% confidence interval [CI]: 0.46 to 0.99; p = 0.048) was lower in the FKB group than the non-FKB group. After propensity score matching (545 pairs), the FKB group had a lower incidence of MACE (adjusted HR: 0.50, 95% CI: 0.30 to 0.85; p = 0.01), and target lesion revascularization in the MV (adjusted HR: 0.51, 95% CI: 0.28 to 0.93; p = 0.03) and both vessels (adjusted HR: 0.47, 95% CI: 0.25 to 0.90; p = 0.02) than in the non-FKB group.ConclusionsIn coronary bifurcation lesions, we demonstrated that the 1-stent technique with FKB was associated with a favorable long-term clinical outcome, mainly driven by the reduction of target lesion revascularization in the MV or both vessels as a result of an increase in minimal lumen diameter. (Korean Coronary Bifurcation Stenting Registry II [COBIS II]: NCT01642992)  相似文献   

2.
ObjectivesThe present study aimed to investigate the difference in major adverse cardiac events (MACE) at 3 years after double-kissing (DK) crush versus culotte stenting for unprotected left main distal bifurcation lesions (LMDBLs).BackgroundThe multicenter and randomized DKCRUSH-III (Comparison of double kissing crush versus culotte stenting for unprotected distal left main bifurcation lesions: results from a multicenter, randomized, prospective study) showed that DK crush stenting was associated with fewer MACE at 1-year follow-up in patients with LMDBLs compared with culotte stenting. Here, we report the 3-year clinical outcome of the DKCRUSH-III study.MethodsA total of 419 patients with LMDBLs who were randomly assigned to either the DK crush or culotte group in the DKCRUSH-III study were followed for 3 year. The primary endpoint was the occurrence of a MACE at 3 years. Stent thrombosis (ST) was the safety endpoint. Patients were classified by simple and complex LMDBLs according to the DEFINITION (Definition and Impact of Complex Bifurcation Lesions on Clinical Outcomes After Percutaneous Coronary Intervention Using Drug-Eluting Stents) study criteria.ResultsAt 3 years, MACE occurred in 49 patients the culotte group and in 17 patients in the DK crush group (cumulative event rates of 23.7% and 8.2%, respectively; p < 0.001), mainly driven by increased myocardial infarction (8.2% vs. 3.4%, respectively; p = 0.037) and target-vessel revascularization (18.8% vs. 5.8%, respectively; p < 0.001) between groups. Definite ST rate was 3.4% in the culotte group and 0% in the DK crush group (p = 0.007). Complex LMDBLs were associated with a higher rate of MACE (35.3%) at 3 years compared with a rate of 8.1% in patients with simple LMDBLs (p < 0.001), with an extremely higher rate in the culotte group (51.5% vs. 15.1%, p < 0.001).ConclusionsCulotte stenting for LMDBLs was associated with significantly increased rates of MACE and ST. (Double Kissing [DK] Crush Versus Culotte Stenting for the Treatment of Unprotected Distal Left Main Bifurcation Lesions: DKCRUSH-III, a Multicenter Randomized Study Comparing Double-Stent Techniques; ChiCTR-TRC-11001877)  相似文献   

3.
ObjectivesThis study sought to evaluate procedural and clinical outcomes among patients undergoing chronic total occlusion (CTO) percutaneous coronary intervention (PCI) using contemporary methods and everolimus-eluting stents (EES).BackgroundLimited studies have detailed the procedural and late-term safety and efficacy of CTO revascularization among multiple centers applying modern techniques and with newer-generation drug-eluting stents.MethodsAmong 20 centers, 250 consecutive patients were enrolled for attempted CTO PCI. Procedural and in-hospital clinical outcomes were examined in addition to the 1-year primary endpoint of death, myocardial infarction, and target lesion revascularization (major adverse cardiac events [MACE]).ResultsDemographic, lesion, and procedural characteristics included prior bypass surgery: 9.9%; diabetes: 40.1%; lesion length: 36.1 ± 18.5 mm; and stent length: 51.7 ± 27.2 mm. Procedural success, defined as guidewire recanalization with no in-hospital MACE, was 96.4%. Success with antegrade-only methods was 97.9% and 86.2% by retrograde/combined methods, respectively. Compared with a pre-specified performance goal derived from 6 prior CTO drug-eluting stent trials (1-year MACE: 24.4%), treatment with EES was associated with significantly lower composite adverse events for both intent-to-treat (18.5%, 1-sided upper confidence interval: 23.4%, p = 0.025) and per-protocol populations (8.2%, 1-sided upper confidence interval: 12.3%, p < 0.0001). Target lesion revascularization at 1 year was 6.3%. Dual antiplatelet therapy adherence was 53.9% at 1 year, yet subacute definite stent thrombosis occurred in only 2 patients (0.9%), and late probable stent thrombosis occurred in 1 patient (0.5%).ConclusionsIn a multicenter registration trial representing contemporary technique and EES, favorable procedural success and late-term clinical outcomes support CTO PCI in a patient population with high lesion complexity. (EXPERT CTO: Evaluation of the XIENCE PRIME LL and XIENCE Nano Everolimus Eluting Coronary Stent Coronary Stents, Performance, and Technique in Chronic Total Occlusions; NCT01435031)  相似文献   

4.
ObjectivesThis study sought to evaluate the optimal percutaneous coronary intervention techniques using drug-eluting stents for bifurcation coronary lesions.BackgroundThe optimal bifurcation stenting technique needs to be evaluated.MethodsThe trial included 2 randomization studies separated by the presence of side branch (SB) stenosis for patients having non–left main bifurcation lesions. For 306 patients without SB stenosis, the routine final kissing balloon or leave-alone approaches were compared. Another randomization study compared the crush or single-stent approaches for 419 patients with SB stenosis.ResultsBetween the routine final kissing balloon and leave-alone groups for nondiseased SB lesions, angiographic restenosis occurred in 17.9% versus 9.3% (p = 0.064), comprising 15.1% versus 3.7% for the main branch (p = 0.004) and 2.8% versus 5.6% for the SB (p = 0.50) from 214 patients (69.9%) receiving 8-month angiographic follow-up. Incidence of major adverse cardiac events including death, myocardial infarction, or target vessel revascularization over 1 year was 14.0% versus 11.6% between the routine final kissing balloon and leave-alone groups (p = 0.57). In another randomization study for diseased SB lesions, 28.2% in the single-stent group received SB stents. From 300 patients (71.6%) receiving angiographic follow-up, between the crush and single-stent groups, angiographic restenosis rate was 8.4% versus 11.0% (p = 0.44), comprising 5.2% versus 4.8% for the main branch (p = 0.90) and 3.9% versus 8.3% for the SB (p = 0.12). One-year major adverse cardiac events rate between the crush and single-stent groups was 17.9% versus 18.5% (p = 0.84).ConclusionsAngiographic and clinical outcomes were excellent after percutaneous coronary intervention using drug-eluting stents with any stent technique for non–left main bifurcation lesions once the procedure was performed successfully.  相似文献   

5.
ObjectivesThis study sought to compare the outcomes of fractional flow reserve (FFR)–guided and angiography (Angio)–guided provisional side-branch (SB) stenting for true coronary bifurcation lesions.BackgroundAngio-guided provisional SB stenting after stenting of the main vessel provides favorable outcomes for the majority of coronary bifurcation lesions. Whether an FFR-guided provisional stenting approach is superior has not been studied.MethodsA total of 320 patients with single Medina 1,1,1 and 0,1,1 coronary bifurcation lesions undergoing stenting with a provisional SB approach were randomly assigned 1:1 to Angio-guided and FFR-guided groups. SB stenting was performed for Thrombolysis In Myocardial Infarction flow grade <3, ostial SB stenosis >70%, or greater than type A dissection after main vessel stenting in the Angio-guided group and for SB-FFR <0.80 in the FFR-guided group. The primary endpoint was the 1-year composite rate of major adverse cardiac events (cardiac death, myocardial infarction, and clinically driven target vessel revascularization).ResultsComparing the Angio-guided and FFR-guided groups, treatment of the SB (balloon or stenting) was performed in 63.1% and 56.3% of lesions respectively (p = 0.07); stenting of the SB was attempted in 38.1% and 25.9%, respectively (p = 0.01); and, when attempted, stenting was successful in 83.6% and 73.3% of SBs, respectively (p = 0.01). The 1-year composite major adverse cardiac event rate was 18.1% in both groups (hazard ratio: 0.91, 95% confidence interval: 0.48 to 1.88; p = 1.00). The 1-year target vessel revascularization and stent thrombosis rates were 6.9% and 5.6% (p = 0.82) and 1.3% and 0.6% (p = 0.56) in the Angio-guided and FFR-guided groups, respectively.ConclusionsIn this multicenter, randomized trial, angiographic and FFR guidance of provisional SB stenting of true coronary bifurcation lesions provided similar 1-year clinical outcomes. (Randomized Study on DK Crush Technique Versus Provisional Stenting Technique for Coronary Artery Bifurcation Lesions; ChiCTR-TRC-07000015)  相似文献   

6.
ObjectivesThe intention this PEPCAD-DES (Treatment of Drug-eluting Stent [DES] In-Stent Restenosis With SeQuent Please Paclitaxel Eluting Percutaneous Transluminal Coronary Angioplasty [PTCA] Catheter) study update was to demonstrate the safety and efficacy of paclitaxel-coated balloon (PCB) angioplasty in patients with DES-ISR at 3 years.BackgroundIn the PEPCAD-DES trial late lumen loss and the need for repeat target lesion revascularization (TLR) was significantly reduced with PCB angioplasty compared with plain old balloon angioplasty (POBA) in patients with drug-eluting stent in-stent restenosis (DES-ISR) at 6 months. We evaluated whether the clinical benefit of reduced TLR and major adverse cardiac events (MACE) was maintained up to 3 years.MethodsA total of 110 patients with DES-ISR in native coronary arteries with reference diameters ranging from 2.5 mm to 3.5 mm and lesion lengths ≤22 mm were randomized to treatment with either PCB or POBA in a multicenter, randomized, single-blind clinical study. With a 2:1 randomization, 72 patients were randomized to the PCB group and 38 patients to the POBA group. At baseline, there were lesions with at least 2 stent layers in PCB (52.8%, 38 of 72) and POBA (55.3%, 21 of 38) patients.ResultsAt 36 months, the TLR rates were significantly lower in the PCB group compared with the POBA control group (19.4% vs. 36.8%; p = 0.046). Multiple TLRs in individual patients were more frequent in the POBA group compared with the PCB group (more than 1 TLR: POBA, 13.2%; PCB, 1.4%; p = 0.021). The 36-month MACE rate was significantly reduced in the PCB group compared with the POBA group (20.8% vs. 52.6%, log-rank p = 0.001).ConclusionsPCB angioplasty was superior to POBA for the treatment of DES-ISR patients in terms of MACE and TLR for up to 36 months. There was no late catch-up phenomenon. (Treatment of Drug-eluting Stent [DES] In-Stent Restenosis With SeQuent® Please Paclitaxel Eluting Percutaneous Transluminal Coronary Angioplasty [PTCA] Catheter [PEPCAD-DES]; NCT00998439)  相似文献   

7.
ObjectivesThe purpose of this study was to investigate the differential clinical outcomes after percutaneous coronary intervention (PCI) for coronary bifurcation lesions with 1- or 2-stenting techniques using first- or second-generation drug-eluting stents (DES).BackgroundThe 2-stenting technique has been regarded to have worse clinical outcomes than the 1-stenting technique after bifurcation PCI with first-generation DES. However, there has been a paucity of data comparing the 1- and 2-stenting techniques with the use of second-generation DES.MethodsPatient-level pooled analysis was performed with 3,162 patients undergoing PCI using first- or second-generation DES for bifurcation lesions from the “Korean Bifurcation Pooled Cohorts” (COBIS [Coronary Bifurcation Stenting] II, EXCELLENT [Registry to Evaluate Efficacy of Xience/Promus Versus Cypher in Reducing Late Loss After Stenting], and RESOLUTE-Korea [Registry to Evaluate the Efficacy of Zotarolimus-Eluting Stent]). The 3-year clinical outcomes were compared between 1- and 2-stenting techniques, stratified by the type of DES.ResultsWith first-generation DES, rates of target lesion failure (TLF) or patient-oriented composite outcome (POCO) (a composite of all death, any myocardial infarction, any repeat revascularization, and cerebrovascular accidents) at 3 years were significantly higher after the 2-stenting than the 1-stenting technique (TLF 8.6% vs. 17.5%; p < 0.001; POCO 18.1% vs. 28.5%, p < 0.001). With second-generation DES, however, there was no difference between 1- and 2-stenting techniques (TLF 5.4% vs. 5.8%; p = 0.768; POCO 11.2% vs. 12.9%; p = 0.995). The differential effects of 2-stenting technique on the prognosis according to the type of DES were also corroborated with similar results by the inverse probability weighted model. The 2-stenting technique was a significant independent predictor of TLF in first-generation DES (hazard ratio: 2.046; 95% confidence interval: 1.114 to 3.759; p < 0.001), but not in second-generation DES (hazard ratio: 0.667; 95% confidence interval: 0.247 to 1.802; p = 0.425).ConclusionsPatient-level pooled analysis of 3,162 patients in Korean Bifurcation Pooled Cohorts demonstrated that the 2-stenting technique showed comparable outcomes to 1-stenting technique with second-generation DES, which is different from the results of first-generation DES favoring the 1-stenting technique.  相似文献   

8.
ObjectivesThe aim of this study was to determine the incidence, predictors, and outcomes of recurrent stent thrombosis (rST).BackgroundPatients who had an initial stent thrombosis (ST) develop may be at high risk of rST.MethodsWe analyzed a multicenter California registry of angiographic definite ST at 5 academic hospitals from 2005 to 2013. A detailed review of the angiogram and procedure was performed of patients with and without rST.ResultsAmong 221 patients with a median follow-up of 3.3 years, definite or probable rST developed in 29, including 19 with angiographic definite rST. The cumulative hazard ratio (HR) of definite or probable rST was 16% at 1 year and 24% at 5 years, whereas the cumulative HR of angiographic definite rST was 11% at 1 year and 20% at 5 years. Despite similar angiographic results, patients who had rST develop had significantly greater peak creatine kinase at the time of initial ST (mean, 2,655 mg/dl vs. 1,654 mg/dl; p = 0.05) than those without rST. The 3-year rate of major adverse cardiovascular events was 50% for patients with rST compared with 22% for patients with a single ST (p = 0.01). After multivariable adjustment, independent predictors of definite/probable rST were age (HR: 1.4; 95 confidence interval [CI]: 1.1 to 1.8 per 10 years), bifurcation ST (HR: 4.4; 95% CI: 1.8 to 10.9), and proximal vessel diameter (HR: 1.8; 95% CI: 1.1 to 3.2 per millimeter).ConclusionsrST represents an important cause of long-term morbidity and mortality after an initial ST. Bifurcation ST and a larger proximal reference vessel diameter are independently associated with an increased risk of rST.  相似文献   

9.
ObjectivesThe aim of this study was to investigate the correlation between in-stent neointimal tissue without features of neoatherosclerosis and long-term clinical outcomes.BackgroundRecent studies have reported differential morphological characteristics of in-stent neointimal tissue assessed by optical coherence tomography (OCT).MethodsThe study population consisted of 336 patients with 368 drug-eluting stent-treated lesions. Patients received a follow-up OCT examination without any intervention. OCT-based neointima was categorized as homogeneous (n = 227 lesions in 208 patients), heterogeneous (n = 79 lesions in 73 patients), or layered (n = 62 lesions in 55 patients). Major adverse cardiac events (MACE) (a composite of cardiac death, nonfatal myocardial infarction, or target lesion revascularization) were assessed according to neointimal patterns during long-term clinical follow-up after OCT examination.ResultsThe time interval between stent implantation and OCT examination was similar among the 3 groups (p = 0.64). On multivariate logistic regression analysis, the significant determinant for the heterogeneous neointima was age (odds ratio [OR]: 1.037, 95% confidence interval [CI]: 1.007 to 1.068, p = 0.015) and an initial clinical presentation of acute coronary syndrome (OR: 1.967, 95% CI: 1.159 to 3.339, p = 0.012). The overall median follow-up duration for all patients after follow-up OCT examination was 31.0 months, and this was statistically different among the heterogeneous group (22.0 months), the homogeneous group (34.0 months), and the layered group (28.0 months, overall p = 0.002). MACE occurred more frequently in patients with heterogeneous neointima over a median 31-month follow-up period after OCT examination (13.7% vs. 2.9% in homogeneous vs. 7.3% in layered, p = 0.001). A propensity score–adjusted Cox regression analysis showed that independent risk factors for MACE were inclusion in the heterogeneous neointima (hazard ratio: 3.925, 95% CI: 1.445 to 10.662, p = 0.007) and minimal lumen cross-sectional area (hazard ratio: 0.368, 95% CI: 0.242 to 0.560, p < 0.001).ConclusionsDetermination of neointimal characteristics is helpful in predicting long-term clinical outcomes. Our data suggest that heterogeneous lesions are linked to poor long-term clinical prognoses.  相似文献   

10.
ObjectivesThis study sought to investigate the clinical outcomes based on the assessment of quantitative coronary angiography–maximal lumen diameter (Dmax).BackgroundAssessment of pre-procedural Dmax of proximal and distal sites has been used for Absorb scaffold size selection in the ABSORB studies.MethodsA total of 1,248 patients received Absorb scaffolds in the ABSORB Cohort B (ABSORB Clinical Investigation, Cohort B) study (N = 101), ABSORB EXTEND (ABSORB EXTEND Clinical Investigation) study (N = 812), and ABSORB II (ABSORB II Randomized Controlled Trial) trial (N = 335). The incidence of major adverse cardiac events (MACE) (a composite of cardiac death, any myocardial infarction [MI], and ischemia-driven target lesion revascularization) was analyzed according to the Dmax subclassification of scaffold oversize group versus scaffold nonoversize group.ResultsOf 1,248 patients, pre-procedural Dmax was assessed in 1,232 patients (98.7%). In 649 (52.7%) patients, both proximal and distal Dmax values were smaller than the nominal size of the implanted scaffold (scaffold oversize group), whereas in 583 (47.3%) of patients, the proximal and/or distal Dmax were larger than the implanted scaffold (scaffold nonoversize group). The rates of MACE and MI at 1 year were significantly higher in the scaffold oversize group than in the scaffold nonoversize group (MACE 6.6% vs. 3.3%; log-rank p < 0.01, all MI: 4.6% vs. 2.4%; log-rank p = 0.04), mainly driven by a higher MI rate within 1 month post-procedure (3.5% vs. 1.9%; p = 0.08). The independent MACE determinants were both Dmax smaller than the scaffold nominal size (odds ratio [OR]: 2.13, 95% confidence interval [CI]: 1.22 to 3.70; p < 0.01) and the implantation of overlapping scaffolds (OR: 2.10, 95% CI: 1.17 to 3.80; p = 0.01).ConclusionsImplantation of an oversized Absorb scaffold in a relatively small vessel appears to be associated with a higher 1-year MACE rate driven by more frequent early MI. (ABSORB Clinical Investigation, Cohort B [ABSORB Cohort B], NCT00856856; ABSORB EXTEND Clinical Investigation [ABSORB EXTEND], NCT01023789; ABSORB II Randomized Controlled Trial [ABSORB II], NCT01425281)  相似文献   

11.
ObjectivesThis study aimed to investigate the clinical outcomes of patients presenting with recurrent drug-eluting stent (DES) in-stent restenosis (ISR) treated with a second-generation DES or with a drug-coated balloon (DCB).BackgroundTo date, there are no reports of DCB treatment and limited data with regard to the efficacy of further DES implantation for recurrent ISR.MethodsBetween January 2008 and December 2013, 171 lesions were assessed for eligibility (82 lesions in the second-generation DES group and 89 lesions in the DCB group).ResultsAcute gain was greater in the second-generation DES group (second-generation DES, 2.09 ± 0.53 mm vs. DCBs, 1.60 ± 0.62 mm, p < 0.001). The rates of major adverse cardiac events were comparable (at 1 year, DES 14.0% vs. DCBs 12.3%; at 2 years, DES 28.8% vs. DCBs 43.5%, p = 0.21). Major adverse cardiac event rates were mainly driven by target lesion revascularization (at 1 year, DES 12.5% vs. DCBs 10.9%; at 2 years, DES 27.7% vs. DCBs 38.3%; p = 0.40). Definite scaffold thrombosis occurred in 2 patients (1 patient in each group). Multivariable analysis revealed ISR recurrence within 1 year (hazard ratio: 2.43, 95% confidence interval: 1.14 to 5.18, p = 0.02) and lesion length (per 10-mm increase) (hazard ratio: 1.15, 95% confidence interval: 1.00 to 1.32, p = 0.049) to be independent predictors of TLR.ConclusionsThe results after both treatments were equivalent. ISR recurrence within 1 year of the first reintervention and lesion length were independent predictors of future target lesion revascularization. Larger studies are required to confirm the late (>1 year) differences with regard to clinical outcomes.  相似文献   

12.
ObjectivesThe aim of the current study was to compare everolimus-eluting stents (EES) with sirolimus-eluting stents (SES) in patients undergoing primary angioplasty.BackgroundDrug-eluting stents may offer benefits in terms of repeat revascularization. However, as shown for first-generation drug-eluting stents, they may be counterbalanced by a potential higher risk of stent thrombosis, especially among patients with ST-segment elevation myocardial infarction (STEMI). No data have been reported so far on the long-term benefits and safety of the new generation of drug-eluting stents in STEMI.MethodsConsecutive STEMI patients admitted within 12 h of symptom onset and undergoing primary angioplasty and stent implantation at a tertiary center with 24-h primary percutaneous coronary intervention capability were randomly assigned to SES or EES. The primary endpoint was a major adverse cardiac event at 3-year follow-up. The secondary endpoints were death, reinfarction, definite or probable stent thrombosis, and target vessel revascularization at 3-year follow-up. No patient was lost to follow-up.ResultsFrom April 2007 to May 2009, 500 patients with STEMI were randomized to EES (n = 250) or SES (n = 250). No difference was observed in terms of baseline demographic and clinical characteristics between the groups. No difference was observed between the groups in terms of number of implanted stents per patient or total stent length. However, a larger reference diameter was observed with SES (3.35 ± 0.51 mm vs. 3.25 ± 0.51 mm, p = 0.001), whereas patients randomized to EES more often received glycoprotein IIb/IIIa inhibitors (54.4% vs. 42.4%, p = 0.006). Follow-up data were available in all patients (1,095 ± 159 days). No significant difference was observed between EES and SES in major adverse cardiac events (16% vs. 20.8%, adjusted hazard ratio [HR]: 0.75 [95% confidence interval (CI): 0.5 to 1.13], p = 0.17), cardiac death (4.4% vs. 5.6%, adjusted HR: 0.77 [95% CI: 0.35 to 1.71], p = 0.53), recurrent MI (6.4% vs. 10%, adjusted HR: 0.62 [95% CI: 0.33 to 1.16], p = 0.13), and target vessel revascularization (4.8% vs. 4.8%, adjusted HR: 1.00 [95% CI: 0.45 to 2.32], p = 0.99). However, EES was associated with a significant reduction in stent thrombosis (1.6% vs. 5.2%, adjusted HR: 0.3 [95% CI: 0.1 to 0.92], p = 0.035).ConclusionsThis study shows that among STEMI patients undergoing primary angioplasty, EES has similar efficacy as SES, but is associated with a significant reduction in stent thrombosis. (Randomized Comparison of Everolimus Eluting Stents and Sirolimus Eluting Stent in Patients With ST Elevation Myocardial Infarction [RACES-MI]; NCT01684982)  相似文献   

13.
ObjectivesThis study aimed to assess the clinical impact of strut width (evaluated by abluminal strut surface area [ASSA]) on periprocedural myocardial infarction (PMI) and clinical outcomes in patients treated with bioresorbable scaffolds (BRS) versus first-generation sirolimus-eluting stents (SES).BackgroundTo date, there are no reports on the impact of ASSA on PMI and clinical outcomes.MethodsWe compared the impact of ASSA on outcomes and PMI in propensity-matched patients treated with BRS and SES. The primary outcome was the incidence of major adverse cardiac events (MACE), defined as the combination of all-cause mortality, follow-up myocardial infarction, and target vessel revascularization, at 30-days and 1-year follow-ups. The secondary endpoint was the incidence of PMI.ResultsAfter propensity-matched analysis, 499 patients (147 BRS patients vs. 352 SES patients) were evaluated. Mean ASSA was higher in patients treated with BRS versus SES (BRS: 132.3 ± 76.7 mm2 vs. SES: 67.6 ± 48.4 mm2, p < 0.001). MACE was not significantly different between groups (30-days MACE: BRS: 0% vs. SES: 1.4%, p = 0.16, and 1-year MACE: BRS: 15.7% vs. SES: 11.4%, p = 0.67). The incidence of PMI was significantly higher in the BRS group (BRS: 13.1% vs. SES: 7.5%, p = 0.05). Multivariable analyses indicated that treatment of left anterior descending artery and ASSA were independent predictors of PMI.ConclusionsBRS implantation, compared with SES implantation, was associated with a higher incidence of PMI. MACE at 30 days and 1 year were not significantly different. Left anterior descending artery percutaneous coronary intervention and ASSA were independent predictors of PMI.  相似文献   

14.
ObjectivesThis study sought to assess the rate and predictors of 1-year restenosis after drug-eluting stent implantation for femoropopliteal (FP) lesions in patients with peripheral arterial disease.BackgroundZilver PTX, a paclitaxel-eluting stent for FP lesions, provides superior outcomes to angioplasty and bare-metal stents in clinical trials. However, its real-world outcomes and the associated features remain unclear.MethodsThis was a prospective multicenter study enrolling 831 FP lesions (797 limbs, 690 patients) treated by Zilver PTX implantation. The primary endpoint was 1-year restenosis. Secondary endpoints included major adverse limb event and stent thrombosis.ResultsMean lesion length was 17 ± 10 cm. One-year restenosis, major adverse limb event, and stent thrombosis rates were 37%, 22%, and 2%, respectively. The generalized linear mixed model showed that lesion length ≥16 cm assessed by angiography and distal external elastic membrane area ≤27 mm2 and minimum stent area ≤12 mm2 assessed by intravascular ultrasound were independent risk factors for restenosis. One-year restenosis rates were 15% in cases with none of these risk factors and 50% in those with ≥2 risk factors.ConclusionsThe current study demonstrated 1-year real-world outcomes after drug-eluting stent treatment for FP lesions, including challenging ones in clinical practice. Lesion length, external elastic membrane area, and minimum stent area were independent predictors for restenosis. (Zilver PTX for the Femoral Artery and Proximal Popliteal Artery—Prospective Multicenter Registry [ZEPHYR]; UMIN000008433)  相似文献   

15.
ObjectivesThis study assessed clinical events and patient-reported chest pain 2 years after treatment of all-comers with Resolute Integrity zotarolimus-eluting stents (Medtronic Vascular, Santa Rosa, California) and Promus Element everolimus-eluting stents (Boston Scientific, Natick, Massachusetts).BackgroundFor both drug-eluting stents (DES), no all-comer outcome data from >12 months of follow-up have been published. Although there is increasing interest in patient-reported chest pain following stenting, data with novel DES are scarce.MethodsThe DUTCH PEERS multicenter trial (TWENTE II) (DUrable Polymer-Based STent CHallenge of Promus ElemEnt Versus ReSolute Integrity) Randomized Trial [TWENTE II]) randomized 1,811 all-comer patients to treatment with 1 type of DES. Monitoring and event adjudication were performed by independent contract research organizations.ResultsThe 2-year follow-up of 1,810 patients (99.9%) was available. The primary composite endpoint target vessel failure occurred in 8.6% and 7.8% of patients treated with zotarolimus- and everolimus-eluting stents, respectively (p = 0.55). Rates of components of target vessel failure were: cardiac death (2.4% vs. 1.9%, p = 0.42); target vessel–related myocardial infarction (2.4% vs. 1.8%, p = 0.33); clinically-indicated target vessel revascularization (4.6% vs. 4.9%, p = 0.83). At 1- and 2-year follow-up, >80% of patients were free from chest pain (no between-stent difference). In addition, >87% of patients were either free from chest pain or experienced pain only at maximal physical exertion, but not during normal daily activities. Patients with chest pain after 12 months at no more than moderate physical effort had a higher risk of target vessel revascularization during the following year (hazard ratio: 1.89 [95% confidence interval: 1.05 to 3.39], p = 0.03).ConclusionsDuring the second year of follow-up, the incidence of adverse clinical endpoints remained similar and low for both DES. The vast majority of patients were free from chest pain.  相似文献   

16.
ObjectivesThe purpose of this study was to compare the 2-year safety and effectiveness of new- versus early-generation drug-eluting stents (DES) according to the severity of coronary artery disease (CAD) as assessed by the SYNTAX (Synergy between Percutaneous Coronary Intervention with Taxus and Cardiac Surgery) score.BackgroundNew-generation DES are considered the standard-of-care in patients with CAD undergoing percutaneous coronary intervention. However, there are few data investigating the effects of new- over early-generation DES according to the anatomic complexity of CAD.MethodsPatient-level data from 4 contemporary, all-comers trials were pooled. The primary device-oriented clinical endpoint was the composite of cardiac death, myocardial infarction, or ischemia-driven target-lesion revascularization (TLR). The principal effectiveness and safety endpoints were TLR and definite stent thrombosis (ST), respectively. Adjusted hazard ratios (HRs) with 95% confidence intervals (CIs) were calculated at 2 years for overall comparisons, as well as stratified for patients with lower (SYNTAX score ≤11) and higher complexity (SYNTAX score >11).ResultsA total of 6,081 patients were included in the study. New-generation DES (n = 4,554) compared with early-generation DES (n = 1,527) reduced the primary endpoint (HR: 0.75 [95% CI: 0.63 to 0.89]; p = 0.001) without interaction (p = 0.219) between patients with lower (HR: 0.86 [95% CI: 0.64 to 1.16]; p = 0.322) versus higher CAD complexity (HR: 0.68 [95% CI: 0.54 to 0.85]; p = 0.001). In patients with SYNTAX score >11, new-generation DES significantly reduced TLR (HR: 0.36 [95% CI: 0.26 to 0.51]; p < 0.001) and definite ST (HR: 0.28 [95% CI: 0.15 to 0.55]; p < 0.001) to a greater extent than in the low-complexity group (TLR pint = 0.059; ST pint = 0.013). New-generation DES decreased the risk of cardiac mortality in patients with SYNTAX score >11 (HR: 0.45 [95% CI: 0.27 to 0.76]; p = 0.003) but not in patients with SYNTAX score ≤11 (pint = 0.042).ConclusionsNew-generation DES improve clinical outcomes compared with early-generation DES, with a greater safety and effectiveness in patients with SYNTAX score >11.  相似文献   

17.
ObjectivesThe aim of this study was to develop a new model for assessment of stenosis severity in a bifurcation lesion including its core. The diagnostic performance of this model, powered by 3-dimensional quantitative coronary angiography to predict the functional significance of obstructive bifurcation stenoses, was evaluated using fractional flow reserve (FFR) as the reference standard.BackgroundDevelopment of advanced quantitative models might help to establish a relationship between bifurcation anatomy and FFR.MethodsPatients who had undergone coronary angiography and interventions in 5 European cardiology centers were randomly selected and analyzed. Different bifurcation fractal laws, including Murray, Finet, and HK laws, were implemented in the bifurcation model, resulting in different degrees of stenosis severity.ResultsA total of 78 bifurcation lesions in 73 patients were analyzed. In 51 (65%) bifurcations, FFR was measured in the main vessel. A total of 34 (43.6%) interrogated vessels had an FFR ≤0.80. Correlation between FFR and diameter stenosis was poor by conventional straight analysis (ρ = −0.23, p < 0.001) but significantly improved by bifurcation analyses: the highest by the HK law (ρ = −0.50, p < 0.001), followed by the Finet law (ρ = −0.49, p < 0.001), and the Murray law (ρ = −0.41, p < 0.001). The area under the receiver-operating characteristics curve for predicting FFR ≤0.80 was significantly higher by bifurcation analysis compared with straight analysis: 0.72 (95% confidence interval: 0.61 to 0.82) versus 0.60 (95% confidence interval: 0.49 to 0.71; p = 0.001). Applying a threshold of ≥50% diameter stenosis, as assessed by the bifurcation model, to predict FFR ≤0.80 resulted in 23 true positives, 27 true negatives, 17 false positives, and 11 false negatives.ConclusionsThe new bifurcation model provides a comprehensive assessment of bifurcation anatomy. Compared with straight analysis, identification of lesions with preserved FFR values in obstructive bifurcation stenoses was improved. Nevertheless, accuracy was limited by using solely anatomical parameters.  相似文献   

18.
ObjectivesThis study sought to investigate the long-term comparative efficacy and safety of paclitaxel-eluting balloon (PEB), paclitaxel-eluting stent (PES), or balloon angioplasty (BA) for the treatment of drug-eluting stent restenosis.BackgroundThe optimal treatment of drug-eluting stent restenosis remains unknown. Although PEB has shown encouraging results, the long-term clinical efficacy and safety of PEB remains poorly defined.MethodsA total of 402 patients with clinically significant restenosis in limus-eluting stents were randomly assigned to receive PEB (n = 137), PES (n = 131), or BA (n = 134). For this analysis, PEB versus PES and PEB versus BA were compared. The primary efficacy and safety endpoints were target lesion revascularization and the composite of death or myocardial infarction.ResultsAt a median follow-up of 3 years, the risk of target lesion revascularization was comparable with PEB versus PES (hazard ratio [HR]: 1.46, 95% confidence interval [CI]: 0.91 to 2.33; p = 0.11) and lower with PEB versus BA (HR: 0.51, 95% CI: 0.34 to 0.74; p < 0.001). The risk of death/myocardial infarction tended to be lower with PEB versus PES (HR: 0.55, 95% CI: 0.28 to 1.07; p = 0.08), due to a lower risk of death (HR: 0.38, 95% CI: 0.17 to 0.87; p = 0.02). The risk of death/myocardial infarction was similar with PEB versus BA (HR: 0.96, 95% CI: 0.46 to 2.0; p = 0.91).ConclusionsAt 3 years, the use of PEB as compared with PES to treat patients with limus-eluting stent restenosis has similar efficacy and safety. PEB remains superior to BA. The sustained efficacy without trade-off in safety supports the role of PEB as treatment option for patients with drug-eluting stent restenosis. (Intracoronary Stenting and Angiographic Results: Drug Eluting Stent In-Stent Restenosis: 3 Treatment Approaches [ISAR-DESIRE 3]; NCT00987324)  相似文献   

19.
ObjectivesThis study sought to investigate the 3-year follow-up results of OLIVE registry patients.BackgroundAlthough favorable 12-month clinical outcomes after endovascular therapy (EVT) in OLIVE registry patients with critical limb ischemia (CLI) from infrainguinal disease have been reported, long-term results after EVT remain unknown.MethodsThis was a prospective multicenter registry study that consecutively enrolled patients who received infrainguinal EVT for CLI. The primary outcome was 3-year amputation-free survival (AFS), whereas secondary outcome measures were 3-year freedom from major adverse limb events (MALE), wound-free survival, and wound recurrence rate. Prognostic predictors for each outcome were also elucidated by Cox proportional hazard regression analysis or the log-rank test.ResultsThe completion rate of 3-year follow-up was 95%. Three-year AFS, freedom from MALE, and wound-free survival rates were 55.2%, 84.0%, and 49.6%, respectively. Wound recurrence out to 3 years was 43.9%. After multivariable analysis, age (hazard ratio [HR]: 1.43, p = 0.001), body mass index ≤18.5 (HR: 2.17, p = 0.001), dialysis (HR: 2.91, p < 0.001), and Rutherford 6 (HR: 1.64, p = 0.047) were identified as predictors of 3-year major amputation or death. Statin use (HR: 0.28, p = 0.02), Rutherford 6 (HR: 2.40, p = 0.02), straight-line flow to the foot (HR: 0.27, p = 0.001), and heart failure (HR: 1.96, p = 0.04) were identified as 3-year MALE predictors. Finally, CLI due to isolated below-the-knee lesion was a wound recurrence predictor (HR: 4.28, p ≤ 0.001). Three-year survival, freedom from major amputation, and reintervention rates were 63.0%, 87.9%, and 43.2%.ConclusionsIn CLI patients with infrainguinal lesions, 3-year clinical results of EVT were reasonable despite high reintervention and moderate ulcer recurrence rate. (A Prospective, Multi-Center, Three-Year Follow-Up Study on Endovascular Treatment for Infra-Inguinal Vessel in Patients With Critical Limb Ischemia [OLIVE 3-Year Follow-Up Study]; UMIN000014759)  相似文献   

20.
ObjectivesThe aim of BIOLUX P-II (BIOTRONIK'S–First in Man study of the Passeo-18 LUX drug releasing PTA Balloon Catheter vs. the uncoated Passeo-18 PTA balloon catheter in subjects requiring revascularization of infrapopliteal arteries) trial was to compare the safety and efficacy of a novel paclitaxel-coated drug-eluting balloon (DEB) versus an uncoated balloon (percutaneous transluminal angioplasty [PTA]) in de novo or native restenotic lesions of the infrapopliteal arteries in patients with claudication and critical limb ischemia.BackgroundDEB have shown promising results in femoropopliteal lesions, but data for infrapopliteal lesions are scarce.MethodsIn this prospective, multicenter, randomized first-in-man study, 72 patients were randomized 1:1 to either a Passeo-18 Lux DEB (Biotronik AG, Buelach, Switzerland) (n = 36) or Passeo-18 PTA (n = 36). Follow-up assessments were scheduled at 1, 6, and 12 months, with angiographic assessment at 6 months. Adverse events were adjudicated by an independent clinical events committee, and angiographic parameters were assessed by an independent core laboratory.ResultsThe primary safety endpoint (a composite of all-cause mortality, target extremity major amputation, target lesion thrombosis, and target vessel revascularization at 30 days) was 0% in the DEB group versus 8.3% in the PTA group (p = 0.239). The primary performance endpoint (patency loss at 6 months) was 17.1% in the DEB group versus 26.1% in the PTA group (p = 0.298), and major amputations of the target extremity occurred in 3.3% versus 5.6% of the patients at 12 months, respectively.ConclusionsThe Passeo-18 Lux DEB has been proven to be safe and effective in infrapopliteal lesions with comparable outcomes to PTA.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号