首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
Three sensitive, selective and reproducible stability-indicating methods are presented for determination of nitazoxanide (NTZ), a new anti-protozoal drug, in presence of its degradation products. Method A utilizes the first derivative of ratio spectra spectrophotometry by measurement of the amplitude at 364.4 nm using one of the degradation products as a divisor. Method B is a chemometric-assisted spectrophotometry, where principal component regression (PCR) and partial least squares (PLS) were applied. These two approaches were successfully applied to quantify NTZ in presence of degradation products using the information included in the absorption spectra in the range 260–360 nm. Method C is based on the separation of NTZ from its degradation products followed by densitometric measurement of the bands at 254 nm. The separation was carried out on silica gel 60F254, using chloroform–methanol–ammonia solution–glacial acetic acid (95:5:1:1 by volume, pH=5.80) as a developing system. These methods are suitable as stability-indicating methods for the determination of NTZ in presence of its degradation products either in bulk powder or in pharmaceutical formulations. Statistical analysis of the results has been carried out revealing high accuracy and good precision.  相似文献   

2.
Two simple, accurate, precise and economic spectrophotometric methods have been developed for simultaneous determination of Atorvastatin calcium (ATR) and Ezetimibe (EZ) in their bulk powder and pharmaceutical dosage form. Method (I) is based on dual wavelength analysis while method (II) is the mean centering of ratio spectra spectrophotometric (MCR) method. In method (I), two wavelengths were selected for each drug in such a way that the difference in absorbance was zero for the second drug. At wavelengths 226.6 and 244 nm EZ had equal absorbance values; therefore, these two wavelengths have been used to determine ATR; on a similar basis 228.6 and 262.8 nm were selected to determine EZ in their binary mixtures. In method II, the absorption spectra of both ATR and EZ with different concentrations were recorded over the range 200–350, divided by the spectrum of suitable divisor of both ATR and EZ and then the obtained ratio spectra were mean centered. The concentrations of active components were then determined from the calibration graphs obtained by measuring the amplitudes at 215–260 nm (peak to peak) for both ATR and EZ. Accuracy and precision of the developed methods have been tested; in addition recovery studies have been carried out in order to confirm their accuracy. On the other hand, selectivities of the methods were tested by application for determination of different synthetic mixtures containing different ratios of the studied drugs. The developed methods have been successfully used for determination of ATR and EZ in their combined dosage form and statistical comparison of the developed methods with the reported spectrophotometric one using F and Student's t-tests showed no significant difference regarding both accuracy and precision.  相似文献   

3.
A simple, precise, accurate stability-indicating gradient reversed-phase high-performance liquid chromatographic (RP–HPLC) method was developed for the quantitative determination of zotepine (ZTP) in bulk and pharmaceutical dosage forms in the presence of its degradation products (DPs). The method was developed using Phenomenex C18 column (250 mm×4.6 mm i.d., 5 µm) with a mobile phase containing a gradient mixture of solvents, A (0.05% trifluoroacetic acid (TFA), pH=3.0) and B (acetonitrile). The eluted compounds were monitored at 254 nm; the run time was within 20.0 min, in which ZTP and its DPs were well separated, with a resolution of >1.5. The stress testing of ZTP was carried out under acidic, alkaline, neutral hydrolysis, oxidative, photolytic and thermal stress conditions. ZTP was found to degrade significantly in acidic, photolytic, thermal and oxidative stress conditions and remain stable in basic and neutral conditions. The developed method was validated with respect to specificity, linearity, limit of detection, limit of quantification, accuracy, precision and robustness as per ICH guidelines. This method was also suitable for the assay determination of ZTP in pharmaceutical dosage forms. The DPs were characterized by LC–MS/MS and their fragmentation pathways were proposed.  相似文献   

4.
Nateglinide has been widely used in the treatment of type-2 diabetics as an insulin secretogoga. A reliable, rapid, simple and sensitive reversed-phase high performance liquid chromatography (RP-HPLC) method was developed and validated for determination of nateglinide in rabbit plasma. The method was developed on Hypersil BDSC-18 column (250 mm×4.6 mm, 5 mm) using a mobile phase of 10 mM phosphate buffer (pH 2.5) and acetonitrile (35:65, v/v). The elute was monitored with the UV–vis detector at 210 nm with a flow rate of 1 mL/min. Calibration curve was linear over the concentration range of 25–2000 ng/mL. The retention times of nateglinide and internal standard (gliclazide) were 9.608 min and 11.821 min respectively. The developed RP-HPLC method can be successfully applied to the quantitative pharmacokinetic parameters determination of nateglinide in rabbit model.  相似文献   

5.
Two selective stability-indicating HPLC methods are described for determination of rabeprazole sodium (RZ)–mosapride citrate (MR) and RZ–itopride hydrochloride (IO) mixtures in the presence of their ICH-stress formed degradation products. Separations were achieved on X-Bridge C18 column using two mobile phases: the first for RZ–MR mixture consisted of acetonitrile: 0.025 M KH2PO4 solution: TEA (30:69:1 v/v; pH 7.0); the second for RZ–IO mixture was at ratio of 25:74:1 (v/v; pH 9.25). The detection wavelength was 283 nm. The two methods were validated and validation acceptance criteria were met in all cases. Peak purity testing using contrast angle theory, relative absorbance and log A versus the wavelengths plots were presented. The % recoveries of the intact drugs were between 99.1% and 102.2% with RSD% values less than 1.6%. Application of the proposed HPLC methods indicated that the methods could be adopted to follow the stability of their formulations.  相似文献   

6.
A gas chromatography mass spectrometry (GC–MS) method has been developed and fully validated for the simultaneous determination of natural borneol (NB) and its metabolite, camphor, in rat plasma. Following a single liquid–liquid extraction, the analytes were separated using an HP-5MS capillary column (0.25 mm×30 m×0.25 μm) and analyzed by MS in the selected ion monitoring mode. Selected ion monitor (m/z) of borneol, camphor and internal standard was 95, 95 and 128, respectively. Linearity, accuracy, precision and extraction recovery of the analytes were all satisfactory. The method was successfully applied to pharmacokinetic studies of NB after oral administration to Wistar rats.  相似文献   

7.
A quality control (QC) strategy for quantitative and qualitative analysis of “common peaks” in chemical fingerprint was proposed to analyze Yuanhu Zhitong tablet (YZT), using high performance liquid chromatography with diode array detector and tandem mass spectrometry (HPLC-DAD–MS/MS). The chromatographic separation was achieved on an Agilent Eclipse plus C18 column with a gradient elution using a mixture of 0.4‰ ammonium acetate aqueous (pH 6.0 adjusted with glacial acetic acid) and acetonitrile. In chemical fingerprint, 40 peaks were assigned as the “common peaks”. For quantification of “common peaks”, the detection wavelength was set at 254 nm, 270 nm, 280 nm and 345 nm, respectively. The method was validated and good results were obtained to simultaneously determine 10 analytes (protopine, jatrorrhizine, coptisine, palmatine, berberine, xanthotoxin, bergapten, tetrahydropalmatine, imperatorin and isoimperatorin). For qualification of “common peaks”, 33 compounds including 10 quantitative analytes were identified or tentatively characterized using LC–MS/MS. These results demonstrated that the present approach may be a powerful and useful tool to tackle the complex quality issue of YZT.  相似文献   

8.
9.
A fast, simple and sensitive high performance liquid chromatographic (HPLC) method has been developed for determination of 10α-methoxy-6-methyl ergoline-8β-methanol (MDL, a main metabolite of nicergoline) in human plasma. One-step liquid–liquid extraction (LLE) with diethyl ether was employed as the sample preparation method. Tizanidine hydrochloride was selected as the internal standard (IS). Analysis was carried out on a Diamonsil ODS column (150 mm×4.6 mm, 5 μm) using acetonitrile–ammonium acetate (0.1 mol/L) (15/85, v/v) as mobile phase at detection wavelength of 224 nm. The calibration curves were linear over the range of 2.288–73.2 ng/mL with a lower limit of quantitation (LLOQ) of 2.288 ng/mL. The intra- and inter-day precision values were below 13% and the recoveries were from 74.47% to 83.20% at three quality control levels. The method herein described was successfully applied in a randomized crossover bioequivalence study of two different nicergoline preparations after administration of 30 mg in 20 healthy volunteers.  相似文献   

10.
A novel method for the simultaneous high-performance liquid chromatographic determination of nortriptyline hydrochloride and fluphenazine hydrochloride was developed and validated. Fluvastatin sodium was used as internal standard. The determination was performed on a Hypersil Gold C8 column (250 mm × 4.6 mm i.d., 5 μm particle size) at 25 °C; the mobile phase, consisting of a mixture of formic acid (0.1 M, pH 2.16)-methanol (33:67, v/v), was delivered at a flow rate of 1.1 mL/min and detector wavelength at 251 nm. The retention time of nortriptyline, fluphenazine and fluvastatin was found to be 5.11, 8.05 and 11.38 min, respectively. Linearity ranges were 5.0–1350.0 and 10.0–1350.0 μg/mL with limit of detection values of 0.72 and 0.31 μg/mL, for nortriptyline and fluphenazine, respectively. Results of assay and recovery studies were statistically evaluated for its accuracy and precision. Correlation coefficients (r2) of the regression equations were greater than 0.999 in all cases. According to the validation results, the proposed method was found to be specific, accurate, precise and could be applied to the simultaneous quantitative analysis of nortriptyline and fluphenazine.  相似文献   

11.
Lamivudine has been widely used in the treatment of HIV disease. A reliable, sensitive reversed phase high performance liquid chromatography (RP-HPLC) method was developed and validated for lamivudine in rabbit plasma. The method was developed on Hypersil BDS C-18 column (250 mm×4.6 mm, 5 μm) using a mobile phase of 0.25% Triethylamine buffer (pH 3.0): acetonitrile (70:30, v/v). The efficient was monitored by UV detector at 256 nm. The total run time was 15 min with a flow rate of 1.0 mL/min. Calibration curve was linear over the concentration range of 25–2000 ng/mL. The retention times of lamivudine and internal standard (Nelfinavir) were 8.78 min and 10.86 min, respectively. The developed RP-HPLC method can be successfully applied for the quantitative pharmacokinetic parameters determination of lamivudine in rabbit model.  相似文献   

12.
13.
A high performance liquid chromatographic method was developed and validated for the quantitative determination of catechin in rat plasma and its pharmacokinetic study after intragastric administration of Catechu and Xiongdanjiangre Wan into SD rats. Plasma samples were prepared by protein precipitation using methanol–5% aqueous zinc sulfate (70:30, v/v) as precipitant. Chromatographic separation was achieved on Hypersil C18 column (250 mm×4.6 mm, 10 μm) with acetonitrile–water–triethylamine (6:94:0.3, v/v/v, pH 4.0±0.1, adjusted with phosphoric acid) as mobile phase, followed by a UV detection at 207 nm. Good linearity was obtained over the range of 0.143–7.15 mg/L of catechin, with correlation coefficient of 0.9992. The method was simple, sensitive, accurate and reproducible and has been successfully applied to the pharmacokinetic study of catechin in rat plasma.  相似文献   

14.
Two highly sensitive methods for the determination of genotoxic alkyl methane sulfonates (AMSs) and alkyl paratoluene sulfonates (APTSs) in lamivudine using hyphenated techniques have been presented. AMSs were determined by GC–MS method using GSBP-INOWAX (30 m×0.25 mm×0.25 μm) column. Temperature program was set by maintaining at 100 °C initially for 3 min, then rised to 220 °C at the rate of 15 °C/min and maintained at 220 °C for 16 min. N,N-dimethyl formamide was used as diluent. APTSs were determined by LC-MS using Zorbax, Rx C8, 250 mm×4.6 mm, 5 μm column as stationary phase. 0.01 M ammonium acetate is used as buffer. The mixture of buffer and methanol in 75:25 (v/v) ratio was used as mobile phase A and mixture of buffer and methanol in 5:95 (v/v) ratio was used as mobile phase B. The gradient program (T/%B) was set as 0/28, 16/50, 17/100, 23/100, 27/28 and 40/28. Both the methods were validated as per International Conference on Harmonization guidelines. Limit of quantitation was found 1.5 μg/mL for AMSs and was in the range of 1.0–1.5 μg/mL for APTSs.  相似文献   

15.
An isocratic stability indicating RP-HPLC–UV method is presented for the determination of metaxalone (MET) in the presence of its degradation products. The method uses Dr. Maisch C18 column (250 mm×4.6 mm, 5 μm) with mobile phase consisting of acetonitrile–potassium dihydrogen orthophosphate buffer with 4 mL of 0.4% triethyl amine (pH 3.0; 10 mM) (58:42, v/v) at a flow rate of 1.0 mL/min. pH of the buffer was adjusted with o-phosphoric acid. UV detection was performed at 225 nm. The method was validated for specificity, linearity, precision, accuracy, limit of detection, limit of quantification and robustness. The calibration plot was linear over the concentration range of 1–100 μg/mL having a correlation coefficient (r2) of 0.999. Limits of detection and quantification were 0.3 and 1 μg/mL, respectively. Intra-day and inter-day precision (% RSD) was 0.65 and 0.79 respectively. The proposed method was used to investigate the degradation kinetics of MET under different stress conditions employed. Degradation of MET followed a pseudo-first-order kinetics, and rate constant (K), time left for 50% potency (t1/2), and time left for 90% potency (t90) were calculated.  相似文献   

16.
A simple, sensitive and high throughput ultra performance liquid chromatography tandem mass spectrometry method has been developed for the determination of mycophenolic acid in human plasma. The method involved simple protein precipitation of MPA along with its deuterated analog as an internal standard (IS) from 50 µL of human plasma. The chromatographic analysis was done on Acquity UPLC C18 (100 mm×2.1 mm, 1.7 µm) column under isocratic conditions using acetonitrile and 10 mM ammonium formate, pH 3.00 (75:25, v/v) as the mobile phase. A triple quadrupole mass spectrometer operating in the positive ionization mode was used for quantitation. In-source conversion of mycophenolic glucuronide metabolite to the parent drug was selectively controlled by suitable optimization of cone voltage, cone gas flow and desolvation temperature. The method was validated over a wide concentration range of 15–15000 ng/mL. The mean extraction recovery for the analyte and IS was >95%. Matrix effect expressed as matrix factors ranged from 0.97 to 1.02. The method was successfully applied to support a bioequivalence study of 500 mg mycophenolate mofetil tablet in 72 healthy subjects.  相似文献   

17.
An isocratic RP-HPLC method was developed for the determination of Cefditoren pivoxil in pharmaceutical formulations using a C-18 column with water–acetonitrile (50:50, v/v) as mobile phase and flow rate 1.2 mL/min (UV detection at 218 nm). Linearity was observed in the concentration range 1.0–250 μg/mL (R2=0.999) with regression equation y=24194x+10749. The forced degradation studies were performed by using HCl, NaOH, and H2O2, and thermal and UV radiation. Cefditoren pivoxil is more sensitive towards oxidation and alkaline conditions and resistant towards acidic and photolytic degradations. The method was validated as per ICH guidelines.  相似文献   

18.
A simple, precise, and rapid high-performance liquid chromatographic method was developed and validated for the simultaneous determination of vitexin-2″-O-glucoside, vitexin-2″-O-rhamnoside, rutin, vitexin, and hyperoside. The HPLC separation was performed using a Shim-pack VP-ODS C18 column (250 mm×4.6 mm i.d., 5 μm) with the isocratic mobile phase consisting of tetrahydrofuran/ acetonitrile/0.05% phosphoric acid solution (20:3:77, v/v/v), and the flow rate was set at 1.0 mL/min. UV detection was carried out at a wavelength of 360 nm and the whole analysis took 25 min. The method was linear in the range of 4.12–206.00 μg/mL for vitexin-2″-O-glucoside, 4.05–202.50 μg/mL for vitexin-2″-O-rhamnoside, 1.64–82.00 μg/mL for rutin, 1.74–87.00 μg/mL for vitexin, and 1.41–70.60 μg/mL for hyperoside with the correlation coefficient for each analyte more than 0.998. The limit of detection (LOD) and limit of quantitation (LOQ) were 0.6 and 2 ng for vitexin-2″-O-glucoside, 0.6 and 2 ng for vitexin-2″-O-rhamnoside, 0.3 and 1 ng for rutin, 1 and 3 ng for vitexin, and 0.5 and 2 ng for hyperoside, respectively. Intra- and inter-day precision and accuracy (RSD) were less than 3%. The developed HPLC method was successfully applied to the analysis of five flavonoids in hawthorn leaves, hawthorn fruits, and the preparations containing hawthorn leaves or fruits.  相似文献   

19.
A simple, specific, precise, sensitive and rapid reverse phase-HPLC method was developed for determination of ketorolac enantiomers, a potent nonnarcotic analgesic in pharmaceutical formulations. The method was developed on a chiral AGP column. Mobile phase was 0.1 M sodium phosphate buffer (pH 4.5): Isopropanol (98:2, v/v), at a flow rate of 1 mL/min with run time of 15 min. Ultraviolet detection was made at 322 nm. The linearity range was 0.02–10 μg/mL for each of the enantiomers. The mobile phase composition was systematically studied to find the optimum chromatographic conditions. Validation of the method under the conditions selected showed that it was selective and precise and that the detector response was linear function of ketorolac.  相似文献   

20.
A stability-indicating high-performance liquid chromatographic method was developed and validated for the determination of Letrozole in tablet dosage forms. Reversed-phase chromatography was performed on Shimadzu Model LC-Class-Vp with Lichrocart/Lichrosphere 100 C-18 (250 mm×4.6 mm, 5 μm particle size) column with methanol: tetra butyl ammonium hydrogen sulfate (80:20V/V) as mobile phase at a flow rate of 1 mL/min with UV detection at 240 nm. Linearity was observed in the concentration range of 0.5–150 μg/mL (R2=0.9998) with regression equation y=102582x+43185. The limit of quantitation (LOQ) and limit of detection (LOD) were found to be 0.043 and 0.012 μg/mL respectively. The forced degradation studies were performed by using HCl, NaOH, H2O2, thermal and UV radiation. Letrozole is more sensitive towards alkaline conditions and very much resistant towards acidic, oxidative and photolytic degradations. The method was validated as per ICH guidelines. The RSD for intra-day (0.78–0.97) and inter-day (0.86–0.96) precision were found to be lesser than 1%. The percentage recovery was in good agreement with the labeled amount in the pharmaceutical formulations and the method is simple, specific, precise and accurate for the determination of Letrozole in pharmaceutical formulations.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号