 共查询到20条相似文献,搜索用时 31 毫秒
1.
We present the 20-year experience of 47 hips in 40 patients aged 50 years or younger with cemented primary total hip arthroplasty using second-generation femoral cementing techniques. Average follow-up duration in the 23 patients living at least 17 years was 18.2 years. Overall, 18 hips (38%) had components revised or removed for any reason, at an average duration of 12.6 years. Every revision or reoperation involved removing the acetabular component. Of these 18 acetabular components, 15 (32%) were revised for aseptic loosening. Eleven additional acetabular components were loose by radiographic criteria at final follow-up, yielding prevalence of aseptic acetabular loosening (55%). Four femoral components (8%) were revised for osteolysis without loosening, and 3 (6%) were revised for aseptic loosening. Femoral osteolysis, with or without component loosening, led to revision in 5 ( 11%) hips compared with 6% for aseptic loosening alone. Osteolysis was the primary problem leading to acetabular and femoral component revision in this series of people < or = 50 years old over the first 20 years after the index operation.  相似文献   

2.
BACKGROUND: Although cementless acetabular components are routinely used in revision hip surgery, few investigators have evaluated the retention and efficacy of these components in the long term. In the current study, the clinical and radiographic outcomes of a series of arthroplasties performed by one surgeon with a cementless acetabular component were assessed at a minimum of ten years. METHODS: From 1986 through 1988, sixty-one consecutive revision total hip arthroplasties were performed in fifty-five patients because of aseptic failure of one or both components of a prosthesis in which both components had been cemented. Twenty-eight patients (thirty-two hips) were alive at a mean of 12.9 years (range, 11.5 to 14.3 years) after the operation. In all of the patients, the acetabular component was revised to a porous-coated Harris-Galante component inserted without cement, and the femoral component was revised to an Iowa component affixed with contemporary cementing techniques. The hips were evaluated clinically and radiographically at a minimum of ten years subsequent to the index revision. No hips were lost to follow-up. RESULTS: None of the acetabular components required revision because of aseptic loosening. Two hips (3%) demonstrated radiographic evidence of aseptic loosening of the acetabular component. The polyethylene liner was exchanged during the follow-up period in eight hips. CONCLUSION: After a minimum of ten years of follow-up, cementless acetabular fixation in revision hip arthroplasty had produced durable results that were markedly better than those reported for acetabular fixation with cement.  相似文献   

3.
Improved cementing techniques have been shown to decrease the rate of aseptic loosening of femoral components of cemented total hip replacements at five to seven years. We now report our results in 105 hips in 93 patients at 10 to 12.7 years (mean 11.2). The improved techniques included use of a medullary plug, a cement gun, a doughy mix of Simplex P and a collared stem of chrome cobalt. Only three femoral components had definitely loosened, none were probably loose and 24 were graded as possibly loose. In contrast, the incidence of radiographic loosening on the acetabular side was 42%. Improved cementing techniques have produced a marked reduction in the rate of aseptic loosening of the femoral component, but the incidence of acetabular loosening is unchanged.  相似文献   

4.
We previously evaluated a cohort of fifty-three patients with severe hip dysplasia (Crowe Type-II, III, or IV subluxation) who underwent a total of sixty-six Charnley total hip arthroplasties. The acetabular component was placed at the anatomic hip center, the superolateral defect was filled with cement, and no bone-grafting was used to supplement the acetabular wall. All but one patient, who was lost to follow-up, were followed until death or for a minimum of twenty years. Radiographic and functional follow-up data were collected prospectively. This retrospective review included twenty-four patients (thirty-four hips) who were alive at a minimum of twenty years following the surgery. Fourteen (22%) of the sixty-five hips underwent revision of a component, with eleven of the revisions performed because of aseptic loosening. Eight of those eleven hips underwent revision because of acetabular loosening alone; two, because of femoral loosening alone; and one, because of loosening of both components. The combined prevalence of revision because of aseptic loosening of the acetabular component and radiographic evidence of failure of the acetabular component was 28% (eighteen hips). With the numbers available, the need for acetabular revision was not associated with the percentage of cement coverage (p = 0.362) or the Crowe classification (p = 0.159). At a minimum of twenty years postoperatively, the survivorship of the acetabular component was 86% +/- 8% with revision because of aseptic loosening as the end point and 82% +/- 10% with revision because of aseptic loosening or radiographic evidence of loosening as the end point. The results that we evaluated at a minimum of twenty years after use of this technique can be compared with the results of other techniques in studies with similar long-term follow-up periods.  相似文献   

5.
In 37 patients, 45 total hip replacements were performed using contemporary cementing techniques, an uncemented Harris-Galante I acetabular component and a cemented precoated Iowa femoral component in patients under the age of 50 at the time of their surgery; 36 patients with 43 hybrid hips were living, 1 patient with 2 hybrid hips was decreased. No patients were lost to follow-up. At 5- to 10-year follow-up, eight hips were revised for aseptic loosening. No acetabular components, and eight femoral components (18%) were revised for aseptic loosening. When looking at radiographic results, including revision as well as those components that were probably or definitely loose on radiographs, 0 acetabular components and 11 femoral components (24%) were radiographically loose. These results demonstrate the excellent durability of the uncemented Harris-Galante acetabular component in the younger patient. However, the Iowa grit-blasted methyl methacrylate precoated femoral component had a magnitude increase in the prevalence of revision for aseptic femoral loosening when compared to the senior author's long-term Charnley results in this age group. The authors attribute the failure to the rough surface finish applied to the femoral component. However, the polymethyl methacrylate proximal precoating and the femoral component design may also contribute to the femoral failures.  相似文献   

6.
BACKGROUND: Loosening of the acetabular component is the major long-term problem associated with total hip arthroplasty with cement. The purpose of the present study was to evaluate the minimum thirteen-year results associated with cementless acetabular components that had been inserted by a single surgeon and to compare them with the results associated with cemented acetabular components that had been inserted by the same surgeon. METHODS: One hundred and twenty consecutive, nonselected primary total hip replacements were performed in 108 patients with use of a Harris-Galante-I cementless acetabular component and a cemented femoral component with a 28-mm head. The patients were evaluated clinically with use of a standard terminology questionnaire, and they were evaluated radiographically for loosening, component migration, wear, and osteolysis. The rates of revision for aseptic loosening and radiographic evidence of loosening for this cohort were compared with the rates for four previously reviewed consecutive series of hips in which the acetabular component had been inserted with cement. All patients were managed by the same surgeon, were followed for thirteen to fifteen years, and were evaluated with use of the same two criteria (revision and loosening) as the end points for Kaplan-Meier analysis. RESULTS: Sixty-six patients (seventy-two hips) were living and forty-two patients (forty-eight hips) had died after thirteen to fifteen years of follow-up. No acetabular component had been revised because of aseptic loosening, and no acetabular component had migrated. With revision of the acetabular component for any reason as the end point, the survival rate was 81% +/- 8% at fifteen years. With revision of the acetabular component for clinical failure (osteolysis, wear, loosening, or dislocation) as the end point, the survival rate was 94% +/- 8% at fifteen years. Among the seventy hips with at least thirteen years of radiographic follow-up, five had pelvic osteolysis and three had had revision of a well-fixed acetabular component because of pelvic osteolysis secondary to polyethylene wear. The mean linear wear rate was 0.15 mm/yr (0.12 mm/yr when one outlier was excluded). CONCLUSIONS: In terms of fixation, Harris-Galante-I cementless acetabular components performed better than did cemented 22-mm-inner-diameter Charnley acetabular components as well as 28-mm-inner-diameter all-polyethylene and metal-backed acetabular components that had been inserted by the same surgeon. However, the rate of wear was greater in association with the Harris-Galante-I cementless components than it was in association with the Charnley cemented all-polyethylene components.  相似文献   

7.
Between 1970 and 1982, cemented total hip replacement without acetabular bone-grafting was performed on fifty-three patients (sixty-six hips) who had had severe congenital dysplasia and coxarthrosis. Of these patients, forty-eight (sixty-one hips) were followed for an average of 8.5 years (range, two to fourteen years). Two have required a revision procedure because of deep infection. No revisions have been performed for aseptic loosening of the prosthesis, but six hips have shown radiographic evidence of loosening. Inadequate medialization of the acetabular component increased the incidence of loosening substantially, but variations in the thickness of the cement, in the volume of cement used, and in the extent of acetabular coverage were not found to be associated with radiographic evidence of loosening. We concluded that the addition of a large, solid, superolateral bone graft above a cemented acetabular component does not decrease the likelihood of loosening and may increase it.  相似文献   

8.
BACKGROUND: The purpose of the present study was to compare the results associated with two different surface finishes (bead-blasted and grit-blasted) for Iowa femoral components used in total hip arthroplasties performed between January 1979 and June 1991 in patients who were less than fifty years old. METHODS: Between January 1979 and December 1985, thirty-six primary total hip replacements were performed in twenty-five patients with insertion of a bead-blasted Iowa femoral component (average surface roughness, 0.8 micrometer) with cement and insertion of a titanium-backed acetabular component (thirty-five hips) or non-metal-backed acetabular component (one hip) with cement. Between January 1986 and June 1991, forty-five primary total hip replacements were performed in thirty-seven patients with use of a precoated grit-blasted Iowa femoral component (average surface roughness, 2.1 micrometers) and a Harris-Galante-I porous ingrowth acetabular component (forty-one hips) or an Osteonics component (four hips). The only change in the design of the femoral component (other than the surface finish) between the two consecutive series was the addition of polymethylmethacrylate precoating to the proximal third of all forty-five grit-blasted stems and modularity of the femoral head of the last eight grit-blasted stems. RESULTS: No hip was lost to follow-up. The duration of radiographic follow-up of the hips treated with the bead-blasted component averaged 11.3 years (range, ten to sixteen years) postoperatively, whereas that of the hips treated with the precoated grit-blasted component averaged 8.2 years (range, five to eleven years). Two (6 percent) of the bead-blasted femoral components were revised because of aseptic loosening compared with eight (18 percent) of the precoated grit-blasted components. Four bead-blasted components (11 percent) were either radiographically loose or were revised because of loosening compared with eleven precoated grit-blasted components (24 percent). Kaplan-Meier survivorship curves evaluated with log-rank analysis revealed that the bead-blasted Iowa femoral components were revised because of aseptic loosening (p = 0.0184) and were radiographically loose (p = 0.0068) less often than the precoated grit-blasted Iowa femoral components. CONCLUSIONS: The findings of the present study have led the senior ones of us to resume using femoral components with a polished surface and fixed with cement.  相似文献   

9.
10.
We studied the results for 168 available hips from a series of 324 consecutive primary total hip arthroplasties that had been performed with insertion of a Harris-Galante-I acetabular component without cement. The acetabulum had been reamed in a so-called line-to-line manner, and the cup had been fixed with one to four screws. A femoral component with a modular alumina-ceramic head had been inserted with cement in all hips. The median duration of follow-up was 112 months (range, 101 to 131 months). Of the original 324 hips, 109 could not be included in the clinical and radiographic follow-up because the patients had died and thirty could not be included because the patients were not available for examination. Seventeen hips had had a revision of the acetabular cup: five, because of infection; five, because of dislocation; three, because of aseptic loosening; and four, because of technical failure. This left 168 hips for clinical and radiographic follow-up; of these, fifteen had had a revision of the femoral component only. Of the remaining 153 hips, which had not had a revision, 147 (96 percent) were considered by the patient to have a satisfactory, good, or excellent result. One hip was found to have a loose cup on radiographic evaluation and was therefore considered to have failed, but the clinical function was good. We concluded that, with an overall rate of aseptic loosening of 1 percent (four of 324) after an intermediate (ten-year) duration of follow-up, use of this cup has good results.  相似文献   

11.
BACKGROUND: Recent studies have suggested that cemented femoral components with a polished surface may provide superior long-term fixation when compared with femoral components with a roughened surface. The purpose of this study was to evaluate the results of total hip arthroplasty with a cemented femoral component with a polished surface finish and compare them with the results of total hip arthroplasty performed with a similar design of cemented femoral component with a rougher surface finish. METHODS: We retrospectively reviewed a consecutive group of 132 patients (149 hips) in whom primary total hip arthroplasty had been performed by one surgeon using a cemented collared femoral component with a polished (0.1-microm Ra) surface finish and a cementless acetabular component. Ninety-eight patients (115 hips) were followed for a minimum of ten years. We compared the survivorship of this prosthesis with that of a femoral component of similar design but with rougher surfaces (matte or grit-blasted). RESULTS: No polished stems were revised because of aseptic loosening or demonstrated radiographic evidence of loosening; however, eight hips (5.4%) with a polished stem demonstrated osteolysis distal to the greater or lesser tro-chanter. In contrast, six stems (2.0%) with a matte surface finish of 0.8-microm Ra were revised because of aseptic loosening, and an additional five stems were seen to be loose radiographically. Eleven stems (9.2%) with a grit-blasted surface finish of 2.1-microm Ra were revised because of aseptic loosening, and an additional four stems were seen to be loose radiographically. The difference in the prevalence of revision due to aseptic loosening between the group with the 0.1-microm Ra surface and the group with the 2.1-microm Ra surface was significant (p = 0.001), as was the difference between the prevalence of revision due to aseptic loosening between the group with the 0.8-microm Ra surface and the group with the 2.1-microm Ra surface (p = 0.001). No cups were revised because of aseptic loosening, and one hip had radiographic signs of acetabular loosening. CONCLUSIONS: This study demonstrated excellent durability of a prosthesis consisting of a cemented, collared, polished femoral component and a cementless acetabular component. While no hips were revised because of aseptic loosening, distal femoral osteolysis was observed in eight hips (5.4%), a higher prevalence than has been reported by others after similar durations of follow-up of tapered, collarless, polished femoral components.  相似文献   

12.
BACKGROUND: Revision of the femoral component of a total hip replacement with use of cement has been associated with early mechanical failure due to aseptic loosening. The purpose of the present study was to determine the long-term survival after revision of the femoral component with cement and to identify factors that were predictive of failure. METHODS: The results of 129 revision total hip arthroplasties that had been performed with use of a cemented femoral stem were reviewed to determine component survival. Ninety-seven hips that had been followed for a minimum of five years were included in survival analysis and tests of significance. Harris hip scores were used to quantify clinical outcomes. Clinical and surgical factors were analyzed to determine whether they were predictive of failure. RESULTS: The mean Harris hip score improved from 52 points preoperatively to 71 points at the time of the most recent follow-up (p < 0.001). The ten-year survival rate was 91% with rerevision of the femoral component because of aseptic loosening as the end point and 71% with mechanical failure as the end point. Patients who were more than sixty years old had greater long-term component survival and less pain than younger patients did (p < 0.05). A good-quality postoperative cement mantle was associated with better long-term radiographic signs of fixation (p < 0.001). Poor femoral bone quality was associated with an increased rate of rerevision for aseptic loosening (p = 0.021). CONCLUSIONS: Revision with use of a cemented femoral component remains an option for selected patients, with an acceptable ten-year survival rate and fair radiographic evidence of fixation. Our patients had acceptable clinical outcomes at ten years, and few had notable pain. The best results may be achieved in older patients (those who are sixty years old or more) with adequate bone stock who are managed with modern cementing techniques.  相似文献   

13.
One hundred and twenty-one primary hybrid total hip replacements were performed in 107 patients. A titanium, porous-coated, hemispherical acetabular component was fixed with screws, and a collared, chromium-cobalt femoral stem, with a roughened surface and a thin layer of methylmethacrylate on the proximal third, was inserted with contemporary cementing techniques (that is, use of a femoral medullary plug, a cement gun, and centrifugation and pressurization of the cement). Fifteen patients (fifteen hips) died before a minimum duration of follow-up of seven years, four patients (four hips) were too ill for a detailed follow-up examination at the time of the study, and two patients (two hips) refused to be evaluated at the time of the latest follow-up. None of these twenty-one hips had had a revision or a reoperation at the time of the latest follow-up. Eighty-six patients (100 hips) were available for clinical follow-up at an average of 120 months (range, eighty-four to 153 months) and for radiographic follow-up at an average of 118 months (range, eighty-four to 153 months). The average age of the patients at the time of the index arthroplasty was sixty-five years (range, forty-five to eighty-seven years). Three acetabular components were revised because of dissociation of the liner in association with a fracture of a locking tine. One well fixed acetabular component was revised because of pelvic osteolysis, and the femoral stem in the same patient was revised because of aseptic loosening. None of the ninety-six remaining acetabular components migrated, was classified as radiographically loose, or was revised because of aseptic loosening. Osteolytic lesions were identified adjacent to five acetabular components, and one of them was treated with bone-grafting around the well fixed acetabular shell. Two hips had a continuous radiolucent line at the interface between the acetabular implant and the bone. Three femoral stems had evidence of radiographic debonding (a radiolucent line that was one millimeter wide or less between the cement and the prosthesis), and they were classified as radiographically loose despite excellent clinical results. Seven hips had osteolytic areas located in the proximal aspect of the most proximal zones of Gruen et al., and five had small osteolytic regions in more distal areas. The Harris hip score for the eighty-two patients (ninety-six hips) who did not have a revision improved from 48 points (range, 22 to 70 points) preoperatively to 92 points (range, 53 to 100 points) at the most recent follow-up examination. Eighty-one patients had no, slight, or mild pain in the hip, and they were satisfied with the clinical result. In the present study, the hybrid total hip replacement with use of the Harris-Galante acetabular component and the Precoat femoral stem continued to provide an excellent result for most patients at an average of approximately ten years after the operation.  相似文献   

14.
A study of implant failure in the Wagner resurfacing arthroplasty   总被引:2,自引:0,他引:2  
Using clinical, radiographic, and pathological data, we investigated eighteen cases of early aseptic failure of an implant in patients who had undergone reconstruction of the hip with a Wagner resurfacing prosthesis. Sixteen patients required revision for loosening of the acetabular component, with eight of them also demonstrating loosening of the femoral component. One patient had loosening of the femoral component without failure of the acetabular component, and one patient sustained a femoral neck fracture that was associated with osteonecrosis. Six of the patients with loosening of the acetabular component had an associated significant loss of acetabular bone stock. Loosening was associated with the development of a membrane at the bone-cement interface in all patients. Histological examination of the membrane demonstrated a marked foreign-body response to wear products from the arthroplasty. Bone resorption appeared active at the bone-membrane interface. We concluded that the acetabular component of the Wagner prosthesis is prone to early loosening and that the early loosening is potentiated by a foreign-body response to debris resulting from arthroplastic wear.  相似文献   

15.
In an attempt to decrease aseptic loosening, total joint components are now being used without cement. Most components are designed to achieve fixation biologically. The radiographic results of 144 primary uncemented total hip arthroplastics and the clinical results of 89 arthroplastics that were performed using a proximally porous-coated titanium alloy femoral stem between November 1983 and June 1989 are reported. On the acetabular side, a threaded component or a hemispherical porous-coated component was used. The patients were followed prospectively for 5 to 9 years postsurgery. During the study period, the threaded acetabular component had a high failure rate. Because it was not possible to determine accurately from which component a particular sign or symptom arose, clinical analysis was restricted to only those hips without a failed or revised cup. Eighty-nine hips in 71 patients with a minimum follow-up period of 5 years were available for clinical review. Radiographic review of the femoral stem was completed on all hips with 5 or more years of radiographic follow-up evaluation, regardless of the status of the acetabular component. One hundred twelve hips in 85 patients were analyzed radiographically. At a latest mean follow-up period of 6.7 years, the mean Iowa hip score was 91.4 ± 8.0 with a 5.4% incidence of thigh pain. Throughout the followup period, the patients with thigh pain had a statistically lower mean Iowa pain subscore when compared with those patients without thigh pain (P = .0001). Endosteal erosion was seen in two hips (1.8%) and longitudinal loss of the medial neck greater than 2 mm was noted in two hips. One femoral stem was revised for aseptic loosening. The clinical results of this femoral stem equal ot exceed the published accounts of other uncemented arthroplasties. The results indicate that the stem is associated with good clinical results, minimal bone loss, and little osteolysis. Continued follow-up evaluation of patients with this femoral stem is necessary to assess the durability of these encouraging results.  相似文献   

16.
Ten-year survivorship of cemented ceramic-ceramic total hip prosthesis.   总被引:4,自引:0,他引:4  
In the first 187 consecutive alumina-alumina combination hip arthroplasties performed from 1977 to 1979, both components were cemented with conventional techniques. At ten-year follow-up evaluation, 87 patients were reviewed or interviewed by telephone, 37 were dead, 39 were lost to follow-up evaluation, and 24 failures were reoperated on before the end of ten years. The major cause of failure was aseptic loosening of the acetabular component (15 failures). Fracture of the socket and of the femoral head occurred in five patients in this series. However, these complications were not seen with components manufactured after 1979. At the end of ten years, survivorship analysis depicted a 82.59% survival rate when reoperation was considered as failure and a 88.57% rate when reoperation for aseptic loosening was considered as failure. The femoral component had a 99.16% survival rate and the acetabular component had an 88.57% survival rate when reoperation for aseptic loosening was considered as failure. Age, appearance of a two- or three-zone demarcation at the intermediate follow-up evaluation, and outer diameter of the acetabular component were the major parameters influencing the results. Better results observed in the population younger than 50 years of age may be related to the small amount of wear debris produced by the alumina-alumina combination. This combination in hip prosthesis is secure, but should be implanted in young and active patients; the outer diameter of the acetabular component must be at least 50 mm. The major problem that remains is the socket's fixation. It could be improved by a design modification, by choosing another mode of fixation, or both.  相似文献   

17.
BACKGROUND: Various studies have reported good long-term results using femoral stems with either smooth or rough surfaces. In this retrospective cross-sectional survivorship study, we reviewed the 10-year results of 51 bilateral staged cemented total hip arthroplasties using the Harvard or the Charnley femoral stems-which have almost similar geometry but a different surface finish. METHODS: 51 patients were reviewed at median interval of 10 (Harvard group) and 11 years (Charnley group) after the primary operation. We evaluated cement mantle thickness, alignment of the components, presence of radiolucent lines, and aseptic loosening. Kaplan-Meier analysis was performed to calculate the survival rate using various endpoints. RESULTS: 8 hips in the Harvard group were revised for aseptic loosening of the femoral component at a median interval of 6.3 years after the primary procedure. 3 hips in the Charnley group were revised for aseptic loosening of the femoral and acetabular components between 10 and 11 years after the primary procedure. The 10-year survival rate for the femoral component using revision surgery for aseptic loosening as an endpoint was 80% (95% CI: 31-42) and 95% (95% CI: 44-47) in the Harvard and the Charnley group, respectively. Cox regression analysis did not reveal any statistically significant effect of various radiographical parameters on the survival rate (p < 0.05). INTERPRETATION: Our results demonstrate that in the group of patients studied, the femoral stem component with the matt surface finish had less satisfactory 10-year survival than the femoral stem of similar design which had a smooth surface finish.  相似文献   

18.
Ninety-nine per cent of the arthroplasties available for follow-up after a minimum of 5 years were assessed clinically and radiologically. Of the original 151 hips, 14 had been reoperated on with exchange of the femoral components because of aseptic loosening. Thirty-one of the 115 re-examined hips showed radiological evidence of femoral component loosening and in 15 hips loosening was suspected. One acetabular component was loose. No deep infection was detected. In 10 of the 31 hips with femoral stem loosening, no complication was suspected after clinical examination only. Varus position of the prosthesis and insufficient cement support at the proximal and distal parts of the stem were associated with increased loosening rates. In patients with a body-weight over 80 kg and in patients younger than 60 years at the operation, loosening had occurred in over 50 per cent of the hips. The clinical overall results were satisfactory, with 79 per cent of the hips being free from significant pain.  相似文献   

19.
BACKGROUND: Use of modern cementing techniques for fixation of femoral components in total hip arthroplasty has had excellent clinical and radiographic results in most patients. However, several authors have described early loosening of femoral components with roughened and precoated finishes. The purpose of this study was to examine the performance of the precoated Iowa stem, which has increased offset, and to compare the results with those of another cemented precoated femoral component with standard offset used at our institution. METHODS: We carried out a prospective analysis of 102 primary hybrid total hip arthroplasties (a cementless acetabular component and a cemented femoral component) performed with use of the Iowa femoral component in ninety-five patients at our institution. The Iowa stem was used in hips that required greater offset than is available with standard stems as determined by preoperative templating. The average age of the patients at the time of the index procedure was sixty-nine years. Sixteen patients (seventeen hips) died before the forty-eight-month minimum follow-up period had elapsed. Two patients were lost to follow-up, and radiographic follow-up was incomplete for one. The mean duration of clinical and radiographic follow-up of the remaining eighty-two hips in the seventy-six surviving patients was sixty-five months (range, forty-eight to 104 months). RESULTS: The average preoperative Harris hip score of 47 points (range, 16 to 69 points) improved to an average of 87 points (range, 24 to 100 points) at the time of the review. Two hips underwent femoral component revision. Four femoral stems were radiographically loose at an average of thirty-four months. Femoral osteolysis was seen in five hips (6 percent) at an average of fifty-four months postoperatively. No acetabular component was revised because of aseptic loosening. According to Kaplan-Meier analysis, the seven-year survival rate, with an end point of femoral revision, osteolysis, or stem debonding, was 90.6 percent (95 percent confidence interval, 0.87 to 0.94). CONCLUSIONS: The prevalence of revision, osteolysis, and loosening after total hip arthroplasty with the Iowa femoral component at our institution was higher than that seen in our series of Harris Precoat stems, which had a survival rate of 98.4 percent (95 percent confidence interval, 0.97 to 1.00) at ten years with the same end points. The design of the Iowa stem may make it difficult to achieve a good cement mantle, and, in combination with the geometry and increased offset of the stem, may compromise the long-term survival of this cemented femoral component.  相似文献   

20.
We report the updated results for a previously evaluated cohort of patients who were less than fifty years old when they underwent Charnley total hip arthroplasty with cement. The original cohort consisted of ninety-three total hip arthroplasties performed in sixty-nine patients. The patients were followed for a minimum of twenty-five years after surgery or until death. The present report describes the findings of the radiographic and functional follow-up, which was performed for forty-two of the forty-three living patients. At the time of the latest follow-up, twenty-nine (31%) of the ninety-three total hip replacements had been revised or removed. Eighteen acetabular and five femoral components were revised secondary to aseptic loosening. The combined prevalence of radiographic failure or revision because of aseptic loosening was 13% for the femoral components and 34% for the acetabular components. Comorbid medical conditions significantly hindered results on each functional subscale (p < 0.05). This study demonstrates the durability of cemented total hip replacements in a young patient population. Sixty-nine percent of the original hip replacements were functioning well at the latest follow-up examination or at the time of death, and only 5% required more than one revision arthroplasty.  相似文献   