首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
To test the clinical significance of technetium-99m teboroxime regional myocardial clearance in the detection of coronary artery disease, 25 patients underwent dynamic planar or single-photon emission tomographic (SPET) myocardial imaging with 99mTc-teboroxime after exercise and again 2 h later at rest. All patients underwent both thallium-201 exercise and redistribution SPET and coronary arteriography. The early phases of exercise 99mTc-teboroxime myocardial clearance determined by dynamic planar imaging showed a significant difference between normal and post-stenotic myocardial regions (clearance rate constant k: 0.047±0.005 min' versus 0.034±0.003 min–1, P <0.001). Reflecting this differential clearance between myocardial regions, an early redistribution-like phenomenon was observed in a significant number of myocaridal segments by comparing serially acquired post-exercise 99mTc-teboroxime SPET images. These results indicated that the analysis of 99mTc-teboroxime myocardial clearance was of potential use in the detection of coronary artery disease, yielding additional information to that provided by the tracer distribution analysis. Although the early redistribution-like phenomenon of 99mTc-teboroxime could be the source of underestimation of ischaemia if acquisition of the initial post-exercise image were delayed, it could also prove useful in the early differentiation of ischaemia from scar because when the phenomenon was observed in delayed post-exercise images, the rest study could be omitted under some circumstances.  相似文献   

2.

Background

Technetium 99m tetrofosmin is a new ethylene diphosphine ligand for myocardial perfusion imaging and has unique properties. We have compared stress-rest single-photon emission computed tomographic (SPECT) imaging with99mTc tetrofosmin with same-day and separate-day rest imaging to detect myocardial perfusion defects.

Methods and Results

Myocardial SPECT imaging was performed in 22 patients with coronary artery disease who had undergone planar thallium 201 imaging and coronary angiography. Single-day (stress-rest) and separate-day rest99mTc tetrofosmin SPECT protocols were compared in the same patient. Images were assessed by a blinded panel to identify myocardial infarction, ischemia, or normal scans. Overall sensitivity for identification of patients with coronary artery disease was 86% (19/22) by both same-day stress-rest and separate-day rest protocols with99mTc tetrofosmin (p=NS). Of a total of 396 segments studied, 107 abnormal segments were identified at exercise and 76 and 81 at the same-day and separate-day rest tests, respectively (p=NS). Same-day stress-rest and separate-day rest99mTc tetrofosmin SPECT protocols were also useful for detecting individual coronary stenosis with a greater than 50% lesion: 80% of the left anterior descending, 93% of the right coronary, and 75% of the left circumflex coronary arteries were detected.

Conclusion

Excellent images were obtained with99mTc tetrofosmin during both stress and rest.99mTc tetrofosmin imaging with the same-day stress-rest and separate-day rest imaging protocols have similar diagnostic sensitivities for detection of coronary heart disease.  相似文献   

3.

Background

Technetium 99m tetrofosmin is a new99mTc-labeled myocardial perfusion agent that can be labeled easily and provides excellent myocardial perfusion images. In addition, bolus administration of the tracer allows first-pass radionuclide ventriculography.

Methods and Results

This study examined the diagnostic value of combined assessment of regional perfusion by tetrofosmin tomography and wall motion by first-pass radionuclide ventriculography both at rest and during stress in 24 patients suspected of having coronary artery disease. All patients underwent stress-rest tetrofosmin tomography, stress-delayed thallium 201 tomography, and coronary angiography. Stress tetrofosmin tomography showed abnormal perfusion in all 23 patients with angiographic evidence of coronary artery disease, whereas stress201Tl tomography showed abnormal perfusion in 22 of the 23 patients. For detection of significant (≥50% diameter stenosis) stenotic coronary arteries, the two perfusion studies showed similar sensitivities (62% with201Tl and 69% with tetrofosmin) and specificities (88% and 100%, respectively). When analysis of regional wall motion was combined with perfusion study, a slightly higher sensitivity was obtained (77%), with similar specificity. The regional wall motion score was concordant with the regional perfusion score in only 42% of the segments at rest and 50% during exercise.

Conclusions

These results suggest that stress tetrofosmin perfusion tomography and stress201Tl tomography provided similar diagnostic accuracy for detection of coronary artery disease. The combined assessment of perfusion and function that is feasible with tetrofosmin may enhance diagnostic accuracy in patients with coronary artery disease.  相似文献   

4.
We compared technetium-99m methoxyisobutylisonitrile (MIBI) myocardial perfusion single-photon emission tomography (SPET) (MPS) and electron beam computed tomography (EBCT) in order to assess their respective value in the detection of coronary artery disease (CAD).99mTc-MIBI SPET (stress-resting) and EBCT studies were performed in 51 patients with suspected CAD who underwent coronary angiography (CAG). CAG showed that of the 51 patients, 36 had coronary stenosis 50% while 15 had normal results. A moderate positive rank correlation was found between coronary calcification detected by EBCT and MPS score (r s=0.5283,P<0.01). The concordance between EBCT and MPS for the evaluation of CAD was 72.5% (37/51). The sensitivity of EBCT in detecting CAD in 51 patients was comparable to that of MPS (81% vs 94%, NS). However, the accuracy of EBCT was lower than that of MPS (78% vs 94%,P<0.025). As regards the detection of individual coronary artery disease, there was no significant difference in sensitivity between EBCT and MPS (65% vs 75%, NS); however, the specificity and accuracy of EBCT were lower than those of MPS (specificity: 77% vs 95%,P<0.005; accuracy 71% vs 85%,P<0.005). The sensitivity, specificity and accuracy of MPS in detecting single-vessel disease were higher than those of EBCT (sensitivity: 86% vs 42%,P<0.025; specificity: 96% vs 70%,P<0.025; accuracy: 93% vs 61%,P<0.005). However, no significant differences in the sensitivity, specificity and accuracy of MPS and EBCT were found in respect of multivessel disease. In conclusion:99mTc-MIBI myocardial perfusion SPET and EBCT provide different information in the assessment of CAD. The sensitivity of EBCT for the detection of CAD is comparable with that of MPS; however, the specificity and accuracy of EBCT are lower than those of MPS. More reliable results will be obtained if both myocardial perfusion SPET and EBCT are performed.  相似文献   

5.
Dobutamine pharmacological stress testing in conjunction with technetium-99m methoxyisobutylisonitrile single-photon emission tomography (MIBI SPET) may be a useful alternative to convential exercise stress MIBI SPET for the detection and localisation of coronary artery stenoses. Therefore, 35 patients with stenoses ( 50% diameter reduction) of one or more coronary arteries were selected for dobutamine MIBI SPET. Each patient underwent MIBI injection at rest and during dobutamine infusion with incremental doses (5, 10, 15 and 20 g kg–1 min–1). A conventional exercise stress test (EST) was performed in all patients. Peak double product during steady-state dobutamine infusion (18 200 ± 4200 mmHg min–1) was lower (P = 0.0001) than during EST (21 700 ± 4900 mmHg min–1). Image quality was good in all but one patient, who had to be excluded from data analysis due to excessive hepatobiliary MIBI activity. Dobutamine-induced perfusion abnormalities were observed in 30/34 MIBI SPET studies, resulting in an overall detection rate for coronary artery disease of 88%. A pathological EST was observed in 23/34 patients (68%). The detection rate of individual coronary artery stenoses was 85% (28/33) for stenosess with a severe diameter reduction (>70%) and 50% (12/24) for stenoses with a moderate diameter reduction ( 50–70%). In particular, sensitivity and specificity for the detection of moderate and severe stenoses ( 50%) were 75%/100% for left anterior descending, 67%/95% for left circumflex and 67%/69% for right coronary artery stenoses. Dobutamine MIBI SPET is a well-tolerated, non-exercise-dependent test for detection and localisation of haemodynamically significant coronary artery stenoses. The use of dobutamine allows a stepwise increase in pharmacological stress similar to EST and is especially useful in patients who are unable to exercise. Correspondence to: E. Voth  相似文献   

6.
Rest technetium-99m sestamibi single-photon emission tomography (SPET) has been shown to under-estimate viability in some patients with chronic ischaemic myocardial dysfunction. The present study was designed to appraise the value of99mTc-sestamibi as a viability tracer in patients with a recent myocardial infarction and to determine factors that might influence its accuracy in assessing infarct size. Therefore, rest99mTc-sestamibi SPET, low-dose dobutamines stress echocardiography and quantitative coronary angiography were performed in 51 patients with a recent myocardial infarction. Perfusion activity and regional wall motion were scored semi-quantitatively using the same segmental division of the left ventricle. Assessment of99mTc-sestamibi uptake as a marker of viability was performed by comparing a binary uptake score (viable=>50% vs necrotic =50% of the maximal tracer activity) with a binary wall motion classification during low-dose dobutamine infusion (viable=normal/hypokinetic vs necrotic=akinetic/dyskinetic). Infarct size, expressed as the number of segments with evidence of necrotic tissue, was significantly greater in the scintigraphic study than in the echocardiographic study (2.8±1.5 vs 2.2±1.3,P=0.006). This overestimation of infarct size by99mTc-sestamibi was present only in patients with a severe infarct-related stenosis (% diameter stenosis 65%–100%) and particularly those with late reperfusion therapy (time delay 180 min). In patients without a severe infarct-related stenosis,99mTc-sestamibi was able to accurately distinguish viable from necrotic segments. Thus, rest99mTc-sestamibi scintigraphy early after acute myocardial infarction may underestimate residual viability within the infarct region, particularly in patients with low flow state coronary anatomy, as a result of a severe infarct-related stenosis and/or late reperfusion therapy.This paper was presented in part at the European Nuclear Medicine Congress, Brussels, Belgium, August 1995  相似文献   

7.
Myocardial single photon emission tomography (SPET) using technetium-99m teboroxime (teboroxime) was studied and the results compared with those of thallium-201(thallium) SPET and coronary arteriography in 19 patients. Resting teboroxime SPET was performed initially. Two hours later, exercise teboroxime SPET was performed. Exercise ergometer tests for both teboroxime and thallium were carried out in a supine position. The levels of exercise achieved for both tests were similar. Agreement for the identification of myocardial segments between thallium SPET and teboroxime SPET was 147/171(86%) (NS). When a significant stenosis was defined as 75% or 50%, agreement between two radiopharmaceuticals for the detection of diseased vessels was 89% (NS, = 0.601) or 88% (NS, = 0.713), respectively. In only 2/19 cases were inferior and posterior segments (3/171) difficult to interpret in teboroxime SPET due to hepatic activity. Thus, teboroxime SPET with a short data acquisition time resulted in a rapid completion for each study and had a good correlation with thallium SPET. Offprint requests to: M. Oshima, M.D., Ph.D. Department of Radiology Nagoya First Red Cross Hospital  相似文献   

8.
The present study was designed to determine the feasibility of using single-photon emission tomography (SPET) imaging with rubidium-81 (T 1/2 = 4.54 h) to detect ischaernic heart disease, using a stress-reinjection protocol and a specially constructed 511-keV hexagonal hole collimator for a standard gamma camera. The diagnostic performance of 81Rb SPET in detecting coronary artery disease (CAD) was investigated in 52 patients with a high prevalence of CAD. Coronary arteriography was performed in 34 patients, 25 of whom were classified as having significant stenosis (50%). At peak exercise (Cornell protocol), 111–222 MBq 81Rb was injected i.v. for stress imaging, and after 3 h of rest, 74–111 MBq was reinjected for rest imaging. The displayed short- and long-axis slices and the polar map images were interpreted qualitatively. In comparison to coronary arteriography, which served as the gold standard, the performance of 81Rb SPET revealed a sensitivity of 95% for the detection of CAD. Images of diagnostic quality were obtained in all patients, these being comparable to thallium-201 SPET images. In conclusion, these results indicate that the described method can be routinely used for the positron emitter 81Rb with a conventional gamma camera and special shielding. 81Rb has the well-known advantages of a potassium analogue and 81Rb SPET permits better visualization, particularly of the posterior wall of the myocardium, due to the higher photon energy. Considering the typical dose of 201Tl used for SPET (74–148 MBq), a 81Rb SPET scan imposes a significantly lower radiation burden on the patient.  相似文献   

9.
The aim of this study was to determine the diagnostic accuracy of technetium-99m tetrofosmin myocardial imaging for the localization of coronary artery stenoses of different degrees of severity. Stress-rest single-photon emission tomography (SPET) was performed on separate days in 80 patients (64 males, 16 females; mean age 61 years; 43 patients with previous myocardial infarction; 18 patients with pharmacological stress), within 6 months of coronary angiography. Scintigraphic images were blindly and independently evaluated by three observers. Coronary stenosis was defined as a >50% narrowing in luminal diameter; severe stenosis was defined as a proximal stenosis of >75% or a peripheral stenosis of >90%. Coronary angiography revealed normal coronary arteries or insignificant coronary stenosis in 13 patients and significant coronary stenoses in 67 patients. The sensitivity and specificity of 99mTc-tetrofosmin SPET in respect of severely stenosed vessels were, respectively, 80% and 65% for the left anterior descending artery (LAD), 100% and 46% for the right coronary artery (RCA) and 58 and 78% for the left circumflex artery (LCx) territories. Considering all the significantly stenosed vessels, a significant decrease in sensitivity was observed for LAD territories (to 59%, P=0.05), and a nonsignificant decrease for RCA (88%) and LCx (47%) territories while specificity values remained essentially unchanged. No significant changes in sensitivity or specificity were observed when regions with previous myocardial infarction were excluded. In conclusion, the sensitivity of 99mTc-tetrofosmin SPET for the localization of individual stenosed vessels is only moderate when all significant stenoses are considered, but the ability of this technique to predict the location of severe coronary artery stenoses seems satisfactory, with the exception of the low specificity in respect of RCA territories. Received 26 April and in revised form 7 June 1997  相似文献   

10.

Background

Pharmacologic coronary vasodilation with adenosine, combined with myocardial scintigraphy, is a useful test for the diagnosis of coronary artery disease (CAD) in patients unable to exercise. It has been demonstrated recently that exercise 99mTc-labeled tetrofosmin cardiac imaging can be used for the detection of CAD. However, no data are available comparing 99mTc-labeled tetrofosmin adenosine and exercise tests in the same patients.

Methods and Results

The results of adenosine and exercise 99mTc-labeled tetrofosmin myocardial tomography were compared in 41 patients (37 men and four women; mean age 53±8 years) with suspected or known CAD who underwent coronary angiography. All patients were submitted, on separate days, to three injections of 99mTc-labeled tetrofosmin (740 MBq intravenously): one at rest, one during bicycle exercise, and one during adenosine infusion (140 μg/kg/min for 6 minutes with injection of 99mTc-labeled tetrofosmin at 4 minutes). A total of 902 myocardial segments were analyzed quantitatively. One patient had normal coronary vessels, 19 patients had single-vessel CAD, 12 patients had two-vessel CAD, and nine patients had three-vessel CAD (>50% coronary stenosis) on coronary angiography. Adenosine induced a significant increase in heart rate (88±16 beats/min at peak vs 72±11 beats/min at rest; p<0.01). Systolic and diastolic blood pressure was not significantly different after adenosine infusion compared with rest. Double product was 22931 ± 7039 at peak exercise and 11229±3413 after adenosine (p<0.01). Agreement on the presence of abnormal single-photon emission computed tomography by adenosine and exercise was 100% by quantitative analysis. In all segments a significant relationship between exercise and adenosine 99mTc-99m-labeled tetrofosmin uptake was observed (r=0.90; p<0.001). Segmental agreement for regional 99mTc-labeled tetrofosmin uptake score between exercise and adenosine was observed in 737 (82%) of the 902 segments (kappa value of 0.66). Concordance between the two studies for identification of perfusion status was observed in 809 (90%) of the segments (kappa value of 0.80). Sensitivity and specificity for detection of stenosed vessels were not different for dynamic exercise stress testing and adenosine 99mTc-labeled tetrofosmin cardiac tomography.

Conclusions

Despite different hemodynamic effects, adenosine and dynamic exercise 99mTc-labeled tetrofosmin single-photon emission computed tomographic imaging provides similar information in the diagnosis and localization of CAD.  相似文献   

11.
Extent and frequency of viable tissue in myocardial segments yielding a perfusion defect on technetium-99m methoxyisobutylisonitrile (99mTc-MIBI), single photon emission tomography (SPET) at rest was prospectively investigated with 2-18F-2-deoxyglucose (18FDG) positron emission tomography (PET) in 46 patients with chronic coronary artery disease (CAD). Of these, 43 had a history of old myocardial infarction. For comparative visual and quantitative evaluation of identical anatomical slices, PET image files were converted into the SPET file structure and into the same matrix size. SPET and PET images were documented and visually (9 segments/patient) or semiquantitatively evaluated by a target-like polar map. Relative perfusion was expressed in percentage of peak 99mTc-MIBI uptake. Sample 18FDG uptake was related to the 18FDG uptake in the area of such maximal perfusion (18FDG uptake was 100% at the 100% 99mTc-MIBI uptake area). Of 414 segments, 167 (40%) revealed a resting perfusion defect. 18FDG uptake was present in 38 (23%) of the defects, while another 40 (24%) segments yielded 18FDG uptake in the periphery of the defect. When grouped according to the degree of 99mTc-MIBI uptake-reduction (in percentage of peak activity), 80% of severe defects (30% of peak uptake), 48% of moderate (31%–50% of peak uptake) and 31% of mild (>50% of peak uptake) defects were considered as non-viable on the basis of 18FDG uptake. Complete viability was found in none of the severe defects in contrast to 29% of moderate and 35% of mild perfusion defects. From these data we conclude that 99mTc-MIBI uptake as a myocardial perfusion marker underestimates myocardial viability in patients with chronic CAD and after myocardial infarction. Nevertheless, only moderate reductions of 99mTc-MIBI uptake seem to imply a greater likelihood for viability. Comparative analysis of metabolism and flow is possible with different tomographic systems and is valuable for clinical evaluation of the cardiac patient. Offprint requests to: C. AltehoeferThis paper presents in part results of the doctoral thesis of C. Feinendegen and was supported in part by the EEC Concerted Action on PET in Cardiology.It is dedicated to Prof. L.E. Feinendegen, Jülich/Düsseldorf on the occasion of his 65th birthday.  相似文献   

12.
A recent, commercially available computer program for the three-dimensional (3D) display of single-photon emission tomography (SPET) data was used to study myocardial perfusion in patients with coronary artery disease (CAD). To enable the detection of small ischemic lesions, the authors proposed a new distance-subtraction method: after suitable centering of the axial slices, 3D distance-shaded images of the stress study were subtracted from the corresponding views of the rest study. With this technique, small changes in surface-to-observer distance were highlighted, thus enabling us to detect nontransmural ischemic areas of the myocardium. General characteristics and possibilities of the subtraction technique were tested on a simple myocardial phantom. Some clinical results of the application of this method on CAD patients are presented and discussed. In CAD patients in whom only nontransmural ischemic lesions are present, the subtraction of distance-shaded images is decisive for a correct diagnosis.  相似文献   

13.
The purpose of this study was to evaluate the long-term prognostic value of exercise technetium-99m methoxyisobutylisonitrile (99mTc-MIBI) single-photon emission tomography (SPET) imaging in patients after percutaneous coronary intervention (PCI). Three hundred and eighteen consecutive post-PCI patients who underwent exercise and rest 99mTc-MIBI SPET myocardial perfusion imaging (MPI) were followed up for 38±27 months. Patients with early revascularisation (<3 months after MPI) were excluded. A semiquantitative visual analysis employing a 20-segment and four-point scoring system was used to define the summed stress score (SSS), summed rest score (SRS) and summed difference score (SDS). Death and non-fatal myocardial infarction (MI) were considered as hard events, and late revascularisation procedures (3 months after MPI) as soft events. Fifty-one patients (16.0%) suffered from cardiac events during follow-up, including 1 (0.3%) death, 13 (4.1%) non-fatal MIs, 9 (2.8%) coronary artery bypass grafting procedures and 28 (8.8%) PCIs. According to the SPET results, patients were classified into three groups: patients with normal MPI (SSS=0, n=153), patients with irreversible defects (SDS<3 and SRS>1, n=100) and patients with reversible defects (SDS3, n=65). The annual hard cardiac event rate in patients with reversible defects was 3.9%, which was significantly higher than that in patients with normal MPI (0.2%, 2=7.71; P<0.01). The annual soft cardiac event rate in patients with reversible defects was 10.7%, which was significantly higher than that in patients with irreversible defects (2.5% 2=17.69; P<0.001), and also significantly higher than that in patients with normal MPI (1.5%, 2=33.89; P<0.001). In patients with normal and reversible defects, there was no significant difference in soft and hard cardiac event rates according to whether patients were symptomatic or asymptomatic (P>0.05). However, the annual soft event rate in patients with irreversible defects and symptoms was 5.0%, which was higher than that of 0.6% in asymptomatic patients (2=6.11, P<0.05). Multivariate Cox analysis showed that SSS was the best independent predictor for hard cardiac events (2=12.70; P<0.001) and SDS was the strongest independent predictor for soft cardiac events (2=11.72; P<0.001). Post-PCI patients who have normal exercise 99mTc-MIBI SPET MPI have a good long-term prognosis, while those with reversible defects are at a higher risk for future cardiac events, without correlation to the chest pain symptoms. However, symptomatic patients with irreversible defects have a higher risk for repeat revascularisation, but not for hard events, compared with asymptomatic patients. Exercise 99mTc-MIBI SPET MPI has important clinical value for risk stratification and management decision-making in post-PCI patients.  相似文献   

14.
This prospective study in 42 patients with chronic coronary artery disease and severe wall motion abnormalities (sWMA) on cineventriculography (24 patients with previous myocardial infarction; ejection fraction, 45%±13%) was designed to compare myocardial thallium-201 uptake after rest injection and normalized fluorodeoxyglucose (18FDG) uptake (after oral glucose load) for assessment of a rest 201Tl protocol to evaluate myocardial viability. The left ventricle was divided into the supply territory of the left anterior descending coronary artery (LAD) and the lateral wall and posterior territory (inferior, posterior and posteroseptal segments) because of the high variability of left circumflex and right coronary artery supply territories. Segmental 201Tl uptake in single-photon emission tomography (SPET) and segmental normalized 18FDG uptake (13 segments per patient) showed a close linear relationship in the LAD territory (r=0.79) and in the lateral wall (r=0.77), while the correlation in the posterior territory was considerably lower (r=0.52). 201Tl/18FDG concordance was defined as an 18FDG uptake exceeding 201Tl uptake by < 20%. Discordance was assumed if 18FDG exceeded 201Tl uptake by at least 20%. Concordant results were shown by 81% (439/541) of segments. In segments with severe 201Tl reduction ( 50% of peak, n=78) discordance was observed in 10% of segments in the LAD territory and lateral wall (n=62) and in 44% of segments in the posterior territory (n=16). In segments with moderate 201Tl reduction (51%–75%, n=205) discordance occured in 12% (LAD and lateral wall, n=126) or 46% (posterior territory, n=79) of segments, respectively. Severe defects were defined as the entire area with 201Tl uptake 50% within a defined territory. Discordance was observed in 6/43 (14%) of these. Of 90 areas with sWMA on cineventriculography, 12 showed discordant results. Ten of these 12 discordant areas affected septum or posterior wall. In areas with normal wall motion or only mild hypokinesis, discordance occured in the septum or posterior wall in 22% whereas the figure for the anterior or lateral wall was only 2%. These results point to a significant role of photon attenuation in 201Tl SPET imaging in the septum and posterior wall. It is concluded that 201Tl SPET using a rest protocol identifies viable myocardium in the supply area of the LAD and in the lateral wall with high accuracy compared to 18FDG positron emission tomography while disordance in the posterior territory may be governed by photon attenuation in the SPET study rather than by a pathophysiological difference. Correspondence to: C. Aftehoefer  相似文献   

15.
Irregular photon attenuation may limit the diagnostic accuracy of myocardial single-photon emission tomography (SPET). The aim of this study was to quantify the potential benefit of attenuation correction by simultaneous emission and transmission imaging for the detection of coronary artery disease (CAD) of vessels supplying the inferoposterior wall segments. In 25 male patients with 50% stenoses of the right coronary artery and/or circumflex artery but without significant narrowing of the left anterior descending artery, stress studies using technetium-99m tetrofosmin (400 MBq) were carried out with and without attenuation correction. A dual-head camera with L-shaped detector positioning was equipped with two scanning gadolinium-153 line sources. Tomograms were reconstructed and quantified using circumferential count rate profiles of myocardial activity (two in each patient). The profiles were compared with the respective normal ranges obtained from a database of 25 male patients with a <10% likelihood of CAD. In patients without CAD, the maximal differences in count density of different wall segments were reduced from 29.0% in non-corrected (NC) studies to 9.5% in attenuation-corrected (AC) studies. In particular, the inferoposterior and septal wall segments were represented by significantly increased relative count densities after attenuation correction. The effects of attenuation correction proved independent of body mass. In patients with CAD, segmental count densities were abnormal in 84% of the NC studies and 100% of the AC studies. In single-vessel disease the stenotic vessel was identified in 66% of cases by NC studies and in 100% by AC studies. In AC studies, the extent and depth of defects exceeded those in NC studies. For the detection of CAD of the right coronary artery, the receiver operating characteristic (ROC) curves relating to the AC studies demonstrated improved discrimination capacity (P<0.05). ROC analysis of CAD detection yielded normalcy rates of 82% (NC) and 94% (AC) for the circumflex artery and 65% (NC) and 97% (AC) for the right coronary artery area at a sensitivity level of 95%. It is concluded that attenuation correction using the above system may enhance the diagnostic accuracy of myocardial SPET when inferoposterior wall segments are to be evaluated.  相似文献   

16.

Background

Receiver operating characteristic (ROC) curve analysis provides detailed information about the performance of a diagnostic test.

Methods and Results

As part of a multicenter phase III trial, 160 patients with known or suspected coronary artery disease underwent planar stress-rest99mTc-labeled tetrofosmin and stress-redistribution201Tl imaging within 14 days of each other, to compare the diagnostic accuracy of these imaging modalities by ROC curve analysis. Coronary arteriography was used as the reference standard and greater than 70% stenosis was considered significant. ROC curve analysis showed improved detection of coronary artery disease with99mTc-labeled tetrofosmin compared with201Tl, with ROC curve areas of 0.765 versus 0.644, respectively (p=0.02).99mTc-labeled tetrofosmin also better identified single-vessel disease in those without previous myocardial infarction (ROC curve areas of 0.684 vs 0.510 for99mTc-labeled tetrofosmin and201Tl, respectively;p=0.04) and enhanced the detection of multivessel disease in those with previous myocardial infarction (ROC curve areas of 0.764 vs 0.638, respectively;p=0.02).

Conclusions

Detailed assessment of diagnostic performance by ROC curve analysis shows that, for planar imaging,99mTc-labeled tetrofosmin enhances the detection of coronary artery disease compared with201Tl.  相似文献   

17.
The ability of single view and biplanar radionuclide ventriculography (RVG) to determine the location of myocardial ischemia during maximal graded supine bicycle exercise was assessed in 50 patients with chest pain, no prior myocardial infarction, and a single coronary stenosis of 50% luminal diameter narrowing at coronary angiography. A biplane collimator was used so that both right anterior oblique (RAO) gated first-pass and left anterior oblique (LAO) equilibrium RVG could be performed at rest and exercise. Results were compared with those obtained using 4-view 201Tl myocardial scintigraphy in the same patients. Regional wall motion abnormalities (WMA) and 201Tl perfusion defects were detected and assigned to individual coronary vessels by agreement between at least two of three independent observers, who read all studies blinded along with those from control subjects with chest pain but no angiographically significant coronary artery disease. When scintigraphic abnormalities were detected, both biplanar RVG (36/39=92%) and 201Tl (25/25=100%) were more frequently correct in predicting the stenosed vessel than single view LAO RVG (24/32=75%) (P<0.05). At RVG only inferior WMA, in the RAO view, predicted right coronary stenosis. Only posterolateral WMA, in the LAO view, predicted left circumflex stenosis. Thus biplanar, but not single view, LAO exercise RVG is a reasonable alternative to exercise 201Tl for localizing exercise-induced ischemic abnormalities to individual coronary stenoses.This work was supported by a Postgraduate Medical Research Scholarship from the National heart Foundation of Australia (Canberra), and by the Alfred Hospital Whole Time Medical Specialists (Melbourne)  相似文献   

18.
The non-invasive diagnosis of coronary artery disease in hypertensives with chest pain is an important clinical concern because all exercise-dependent tests display limited feasibility and diagnostic accuracy; by contrast, dipyridamole echocardiography testing has been shown to have a similar feasibility and accuracy in hypertensive and normotensive subjects. The aim of this study was to evaluate the diagnostic capability of technetium-99m sestamibi tomography based on dipyridamole echocardiography testing in hypertensives with chest pain, and to compare the scintigraphic results with those of coronary angiography, exercise electrocardiography and dipyridamole echocardiography. Forty subjects with mild to moderate hypertension, chest pain and no previous myocardial infarction were submitted to99mTc-sestamibi tomography (at rest and after high-dose dipyridamole echocardiography) and to exercise electrocardiography testing. At coronary angiography 22 patients (group A) had significant epicardial coronary artery disease (70% stenosis of at least one major vessel) and 18 normal main coronary vessels (group B). Dipyridamole99mTc-sestamibi imaging was positive in 21/22 patients of group A and in 5/18 of group B. Dipyridamole echocardiography was positive in 18/22 patients of group A and in 5/18 of group B. Exercise electrocardiography was positive in 15/22 patients of group A and in 11/18 of group B. Four out of five subjects in group B with positive results in all the tests showed a slow run-off of angiographic contrast medium, probably due to small-vessel disease. Significant epicardial coronary artery disease in hypertensives with chest pain is unlikely when dipyridamole99mTc-sestamibi tomography is negative. When scintigraphy is positive, either epicardial coronary artery disease or a small-vessel disease condition is possible. The association of scintigraphy with dipyridamole echocardiography testing allows the assessment of contractile function and myocardial perfusion by a single pharmacological stress.  相似文献   

19.
This study investigated the value of technetium-99m sestarnibi scintigraphy in identifying patients at risk for post-infarct ischaemia (=jeopardized myocardium), especially within the reperfused infarct region. In 51 patients with a recent (99mTc-sestamibi single-photon emission tomography (SPET) and dobutamine stress echocardiography (DSE) were performed and correlated with the presence of significant coronary artery stenosis [% diameter stenosis (DS) >50%] on quantitative coronary angiography. Regional perfusion activity was analysed semiquantitatively (score 0–4) on a 13-segment left ventricular model. DSE was used for the estimation of the infarct size (low-dose DSE) and for concomitant evaluation of ischaemia (high-dose DSE). A reversible perfusion defect within the infarct region was observed in 20 of the 37 patients with a significant infarct-related lesion (sensitivity of 54%) and only in one patient without a significant infarct-related lesion (specificity of 93%). Further analysis revealed that the scintigraphic assessment of jeopardized myocardium was fairly good in patients with a moderate (DS 51%–64%) infarct-related stenosis but was inadequate in patients with a severe (DS65%) infarct-related stenosis (sensitivity of 80% vs 36%,P<0.01), while the echocardiographic detection of ischaemia was not influenced by stenosis severity (sensitivity of 73% in both subgroups). This scintigraphic under-estimation of jeopardized myocardium was mainly related to a severely impaired myocardial perfusion under baseline conditions, as was evidenced by a significantly more severe rest perfusion score in the infarct region in patients with a severe stenosis as compared to those with a moderate stenosis (average score: 1.5±0.7 vs 2.1±0.6,P<0.01), while infarct size on echocardiography was similar for both subgroups. It may be concluded that early after an acute myocardial infarction, adenosine99mTc-sestamibi SPET may underestimate reperfused but still jeopardized myocardium, particularly in patients with a severe infarct-related stenosis. In these patients the evaluation of the ischaemic burden on rest-stress scintigraphy is hampered by the presence of a severely impaired myocardial perfusion in resting conditions.  相似文献   

20.
Dementia of the Alzheimer-type (DAT) is characterized by progressive cognitive decline, variably combined with frontal lobe release signs, parkinsonian symptoms and myoclonus. The features of diffuse Lewy body disease (DLBD), the second most common cause of degenerative dementia, include progressive cognitive deterioration, often associated with levodopa-responsive parkinsonism, fluctuations of cognitive and motor functions, psychotic symptoms (visual and auditory hallucinations, depression), hypersensitivity to neuroleptics and orthostatic hypotension. A recent report suggests that positron emission tomography studies in patients with degenerative dementia may be useful in the differential diagnosis of DAT and DLBD. However, the diagnostic role of single-photon emission tomography (SPET) studies remains to be established. The aim of this study was therefore to evaluate regional cerebral perfusion [with either technetium-99m hexamethylpropylene amine oxime (99mTc-HMPAO) or99mTc-ethyl cysteinate dimer (99mTc-ECD) SPET] and striatal dopamine transporter density [using iodine-123 2-carboxymethoxy-3-[4-iodophenyl]tropane (123I--CIT) SPET] in patients with DAT and DLBD. Six patients with probable DAT and seven patients with probable DLBD were studied. Blinded qualitative assessment by four independent raters of99mTc-HMPAO or99mTc-ECD SPET studies revealed bilateral temporal and/or parietal hypoperfusion in all DAT patients. There was additional frontal hypoperfusion in two patients and occipital hypoperfusion in one patient. In the DLBD group, regional cerebral perfusion had a different pattern. In addition to temporoparietal hypoperfusion there was occipital hypoperfusion resembling a horseshoe defect in six of seven patients. In the DAT group, the mean 3-h striatal/cerebellar ratio of123I--CIT binding was 2.5±0.4, with an increase to 5.5±1.1 18 h after tracer injection. In comparison, in the DLBD patients the mean 3-h striatal/cerebellar ratio of123I--CIT binding was significantly reduced to 1.7±0.3, with a modest increase to 2.1±0.4 18 h after tracer injection (P<0.05, Scheffe test, ANOVA). These results suggest that99mTc-HMPAO or99mTc-ECD and123I--CIT SPET may contribute to the differential diagnosis between DAT and DLBD, showing different perfusion patterns and more severe impairment of dopamine transporter function in DLBD than in DAT.  相似文献   