共查询到20条相似文献,搜索用时 10 毫秒
1.
Comparison of agar disk diffusion, microdilution broth, and agar dilution for testing antimicrobial susceptibility of coagulase-negative staphylococci. 总被引:1,自引:3,他引:1 下载免费PDF全文
J A Smith D A Henry A M Bourgault L Bryan G J Harding D J Hoban G B Horsman T Marrie P Turgeon 《Journal of clinical microbiology》1987,25(9):1741-1746
A collection of 120 oxacillin-susceptible and 120 oxacillin-resistant coagulase-negative staphylococci (CNS) from six tertiary care hospital laboratories were tested by agar disk diffusion, three microdilution broth systems (Sensititre, Dynatech, and Alpkem), and the Vitek AutoMicrobic system for comparison with reference agar dilution results. The antimicrobial agents tested were oxacillin, cefazolin, cefotaxime, cefuroxime, cefamandole, fusidic acid, rifampin, and vancomycin. Incubation was at 30 or 35 degrees C for 24, 48, and 72 h. The broth media were supplemented with 2% NaCl for some antimicrobial agents, and the agar dilution method was used with and without the addition of 4% NaCl. The CNS were identified to species by the method of Kloos and Schleifer. The results showed a lack of concordance between two hospitals with respect to oxacillin susceptibility testing by agar dilution with no NaCl supplement. The reasons are not clear but may be related to variations in media. The 4% NaCl supplement or extended incubation to 48 h eliminated this difference. The cefazolin and cefotaxime susceptibility results in the agar disk diffusion test were unreliable if accepted at face value. Cefamandole testing correlated well with the reference method regardless of the method used, and salt supplementation is not recommended. Most of the oxacillin-resistant CNS were resistant to the other beta-lactam drugs except cefamandole. Of 22 CNS resistant to cefamandole, 21 were S. haemolyticus. 相似文献
2.
Comparison of agar dilution, broth microdilution, E-test, disk diffusion, and automated Vitek methods for testing susceptibilities of Enterococcus spp. to vancomycin. 下载免费PDF全文
P C Kohner R Patel J R Uhl K M Garin M K Hopkins L T Wegener F R Cockerill rd 《Journal of clinical microbiology》1997,35(12):3258-3263
An evaluation was undertaken to determine the optimal method for testing the susceptibilities of 100 clinical isolates and two reference strains of Enterococcus spp. to vancomycin in vitro. Six testing methods were studied by using the following media and incubation times: agar screen with the Synergy Quad Plate (Remel, Lenexa, Kans.), an in-house-prepared brain heart infusion (BHI) agar plate, and an in-house-prepared Mueller-Hinton (MH) agar plate, all incubated for 24 or 48 h; broth microdilution (Sensititre Just One Strip; AccuMed International, Inc., West Lake, Ohio) with BHI or cation-adjusted MH broth incubated for 24 or 48 h; agar dilution with BHI or MH agar incubated for 24 or 48 h; epsilometer test (E test; AB BioDisk, Solna, Sweden) with BHI or MH agar incubated for 24 or 48 h; disk diffusion with BHI or MH agar incubated for 24 or 48 h; and the automated Vitek method with the gram-positive susceptibility Staphylococcus aureus card and R02.03 software (bioMerieux, Inc., Hazelwood, Mo.). Growth failures occurred with MH media (n = 6) but not with BHI media. One growth failure occurred with the Vitek method. Results for each testing method for each Enterococcus strain were interpreted as susceptible, intermediate, or resistant according to current National Committee for Clinical Laboratory Standards (NCCLS) criteria and compared to the vancomycin resistance genotype (i.e., vanA, vanB, vanC-1, or vanC-2/3). For all methods, extension of the incubation time from 24 h to 48 h either produced no difference in the results or gave poorer results. The following methods produced no very major or major interpretive errors: broth microdilution with BHI media incubated for 24 h, agar dilution with BHI media incubated for 24 or 48 h, and E test with BHI media incubated for 24 or 48 h. Unacceptable frequencies of very major errors (> 1%) occurred with all methods for which MH media were used. Minor interpretive errors were frequent with all methods. These minor interpretive errors also occurred most frequently with Enterococcus strains with vanC genes, which encoded low-level vancomycin resistance (MIC < or = 8 microg/ml), as opposed to Enterococcus strains which possessed vanA or vanB genes, which encoded higher-level vancomycin resistance (MIC > or = 64 microg/ml). Modification of NCCLS breakpoints, especially for motile Enterococcus spp. (E. casseliflavus, E. flavescens, and E. gallinarum), may resolve this problem; however, in the current study, one E. faecalis strain and one E. faecium strain carried only the vanC gene. The agar screen method may also require reformulation. The current agar screen plate contains 6 microg of vancomycin per ml, which may not detect all low-level resistance associated with vanC genotypes. Nevertheless, the clinical significance of this low-level vancomycin resistance remains unknown. 相似文献
3.
The E Test (AB Biodisk, Solna, Sweden) is a new method for performing antimicrobial susceptibility tests. It consists of an impervious carrier (5- by 50-mm strip) with a predefined antimicrobic gradient which is placed on an inoculated agar plate and processed like a disk diffusion test. Results are generated directly as MICs from a continuous concentration gradient covering 15 twofold dilutions, and MICs are read where the edge of the inhibition zone intersects the strip. We compared the E Test with disk diffusion, broth microdilution, and agar dilution tests by using a challenge set of 195 gram-positive and gram-negative bacteria for 14 antimicrobial agents. Also, disk diffusion, broth microdilution, and agar dilution tests were compared with each other. All test method comparisons gave greater than 94% agreement for the category of susceptibility. The E Test category agreement with disk diffusion and broth microdilution was 95.1%, and with agar dilution it was 95.2%. The E Test results were as reliable as the results obtained by the standard antimicrobial susceptibility testing methods. 相似文献
4.
Metronidazole susceptibility testing for Helicobacter pylori: comparison of disk, broth, and agar dilution methods and their clinical relevance. 总被引:4,自引:2,他引:4 下载免费PDF全文
A J DeCross B J Marshall R W McCallum S R Hoffman L J Barrett R L Guerrant 《Journal of clinical microbiology》1993,31(8):1971-1974
Since the methods for metronidazole susceptibility testing of Helicobacter pylori have not been standardized or validated, we compared three methods that are used to test the metronidazole susceptibilities of 25 isolates of H. pylori. Specifically, we examined the methods of Steer's replicator agar dilution, tube broth microdilution, and modified Kirby-Bauer disk diffusion. The metronidazole disk zone sizes obtained by the disk diffusion method correlated well (r = 0.74) with the MICs obtained by the agar dilution method. Afterward, the disk diffusion method was used to characterize the metronidazole susceptibilities of 44 isolates of H. pylori. Dual therapy (bismuth and metronidazole) proved to be highly effective against metronidazole-susceptible strains (81.6% eradication rate) but fared poorly against resistant strains (16.7% eradication rate; P < 0.01). Using agar dilution testing, we validated the modified Kirby-Bauer disk diffusion method for metronidazole susceptibility testing of H. pylori and conclude that it is practical, accurate, and clinically applicable. 相似文献
5.
Comparison of broth microdilution,E Test,and agar dilution methods for antibiotic susceptibility testing of Campylobacter jejuni and Campylobacter coli 下载免费PDF全文
A standardized broth microdilution method was compared to the E test and an agar dilution method for the antimicrobial susceptibility testing of Campylobacter jejuni and C. coli isolates. A group of 47 human clinical isolates, 37 isolates from retail poultry, and 29 isolates from living turkeys (total, 113 isolates) was included in the study. These encompassed 92 C. jejuni and 21 C. coli strains. The MICs of six antimicrobial agents were determined by the broth microdilution and E test methods, and the strains of human origin were additionally tested by the agar dilution method. In general, broth microdilution MICs agreed within 1 log(2) MIC increment with 90.0% of E test results and 78.7% of agar dilution test results. The agar dilution method gave much lower gentamicin MICs than the broth microdilution method, but the data were significantly (P < 0.01) correlated and there was 100% agreement in the sensitivities and specificities in the comparison of the tests. The broth microdilution method had the highest sensitivity for analysis of the susceptibilities of Campylobacter to nalidixic acid and trimethoprim-sulfamethoxazole. The MICs of ciprofloxacin and erythromycin complied numerically by all three methods. The classification of the results and the correlation of the data demonstrated a high degree of agreement. All methods were equally suitable for the testing of the sensitivity of Campylobacter to tetracycline. Thus, the broth microdilution method appears to be an easy and reliable method for determination of the MICs of antibiotics for C. jejuni and C. coli, and it may offer an interesting alternative to MIC determination by the agar dilution technique or the E test. 相似文献
6.
Kohanteb J Bazargani A Saberi-Firoozi M Mobasser A 《Indian journal of medical microbiology》2007,25(4):374-377
PURPOSE: To assess the pattern of antimicrobial susceptibility profile of Helicobacter pylori isolates from patients with gastritis, duodenal ulcer (DU) and gastroesophageal reflux disease (GERD) residing in Shiraz, Iran. METHODS: One hundred and six H. pylori isolates from patients with gastritis, DU and GERD undergoing endoscopy at our university hospitals and clinics were analysed for their antimicrobial susceptibility to metronidazole, clarithromycin, amoxicillin, co-amoxiclav, tetracycline, ciprofloxacin and furazolidone. The minimum inhibitory concentrations were determined by agar dilution method. RESULTS: Overall H. pylori resistance rate was 72.6% to metronidazole, 9.4% to clarithromycin and furazolidone, 20.8% to amoxicillin and 4.7% to tetracycline and ciprofloxacin. No resistance to co-amoxiclav was detected among H. pylori isolates. No significant differences between antimicrobial resistance and clinical outcome were detected. CONCLUSIONS: With regard to the increasing resistance of H. pylori isolates to various antibiotics, susceptibility testing of H. pylori isolates prior to the treatment of infection must be performed to achieve better eradication and to reduce the risk of selection of H. pylori resistant strains. 相似文献
7.
Comparison of E test with agar dilution for antimicrobial susceptibility testing of Neisseria gonorrhoeae. 总被引:1,自引:4,他引:1 下载免费PDF全文
A collection of 150 Neisseria gonorrhoeae isolates from Africa, where various resistance mechanisms among N. gonorrhoeae isolates are common, was used to the compare E test (AB Biodisk, Solna, Sweden) with agar dilution susceptibility testing. MICs obtained by the E test agreed within 1 log2 concentration by the agar dilution method for 97.5, 97.3, 96.6, 94, and 84.7% of the tested isolates for penicillin, ciprofloxacin, chloramphenicol, tetracycline, and trimethoprim-sulfamethoxazole, respectively. No significant difference in susceptibility categorization was observed between either method. The E test is an attractive alternative to the agar dilution technique and is a more appropriate method for N. gonorrhoeae susceptibility testing in developing countries. 相似文献
8.
Evaluation of the E test for quantitative antimicrobial susceptibility testing of Helicobacter pylori. 总被引:4,自引:3,他引:4 下载免费PDF全文
Y Glupczynski M Labb W Hansen F Crokaert E Yourassowsky 《Journal of clinical microbiology》1991,29(9):2072-2075
The Progressive Diagnostics Manufacturers epsilometer test (E test; AB Biodisk, Solna, Sweden), a quantitative variant of the disk diffusion technique, was evaluated comparatively to an agar dilution method for the antimicrobial susceptibility testing of Helicobacter pylori. A collection of 79 H. pylori clinical strains, including isolates with known resistance to various antimicrobial agents, was tested against 12 different antimicrobial agents. All strains were tested on Columbia agar supplemented with 10% horse blood. Plates were incubated at 37 degrees C in microaerobic atmosphere (5% O2, 10% CO2), and readings were done after 3 days of incubation. In general, E test MICs were easy to interpret and the correlation between MICs by the agar dilution method and the E test was good, with 86 and 99.5% of results being within, respectively, 1 and 2 log2 dilution steps in a total of 936 tests. All strains of H. pylori with documented resistance to the tested agents were detected by the E test. Thus, the E test appears to be an easy and reliable method for determination of MICs of antibiotics for H. pylori, and it may offer an interesting alternative to MIC determination by the agar dilution technique. 相似文献
9.
10.
Comparison of agar dilution, tube dilution, and broth microdilution susceptibility tests for determination of ramoplanin MICs. 下载免费PDF全文
Standard broth microdilution (with and without bovine serum albumin [BSA] supplementation), tube dilution, and agar dilution susceptibility tests were compared for determining ramoplanin MICs. With a data base of 246 clinical isolates of gram-positive bacteria from 33 U.S. sites, it was shown that (i) agar and tube dilution susceptibility tests gave essentially the same results (93.9% of the test results were within 1 doubling dilution of equivalence), (ii) broth microdilution susceptibility tests gave results up to 5 doubling dilutions higher than agar or tube assays, and (iii) this data skewing could be reversed by BSA supplementation (final concentration, 0.02%) of the broth microdilution test medium. 相似文献
11.
Collaborative investigation of broth microdilution and semisolid agar dilution for in vitro susceptibility testing of Candida albicans. 下载免费PDF全文
R Shawar V Paetznick Z Witte L G Ensign E Anaissie M LaRocco 《Journal of clinical microbiology》1992,30(8):1976-1981
A study was performed in two laboratories to evaluate the effect of growth medium and test methodology on inter- and intralaboratory variations in the MICs of amphotericin B (AMB), flucytosine (5FC), fluconazole (FLU), itraconazole (ITRA), and the triazole Sch 39304 (SCH) against 14 isolates of Candida albicans. Testing was performed by broth microdilution and semisolid agar dilution with the following media, buffered to pH 7.0 with morpholinepropanesulfonic acid (MOPS): buffered yeast nitrogen base (BYNB), Eagle's minimal essential medium (EMEM), RPMI 1640 medium (RPMI), and synthetic amino acid medium for fungi (SAAMF). Inocula were standardized spectrophotometrically, and endpoints were defined by the complete absence of growth for AMB and by no more than 25% of the growth in the drug-free control for all other agents. Comparative analyses of median MICs, as determined by each test method, were made for all drug-medium combinations. Both methods yielded similar (+/- 1 twofold dilution) median MICs for AMB in EMEM and RPMI, 5FC in all media, and FLU in EMEM, RPMI, and SAAMF. In contrast, substantial between-method variations in median MICs were seen for AMB in BYNB and SAAMF, FLU In BYNB, and ITRA and SCH in all media. Interlaboratory concordance of median MICs was good for AMB, 5FC, and FLU but poor for ITRA and SCH in all media. Endpoint determinations were analyzed by use of kappa statistical analyses for evaluating the strength of observer agreement. Moderate to almost perfect interlaboratory agreement occurred with AMB and 5FC in all media and with FLU in EMEM, RPMI, and SAAMF, irrespective of the test method. Slight to almost perfect interlaboratory agreement occurred with ITRA and SCH in EMEM, RPMI, and SAAMF when tested by semisolid agar dilution but not broth microdilution. Kappa values assessing intralaboratory agreement between methods were high for 5FC in all media, for AMB in BYNB, ENEM, and RPMI, and for FLU in EMEM, RPMI, and SAAMF. One laboratory, but not the other, reported substantial to almost perfect agreement between methods for ITRA, and SCH in EMEM, RPMI, and SAAMF. Both laboratories reported poor agreement between methods for the azoles in BYNB. Discrepancies noted in azole-BYNB combinations were largely due to the greater inhibitory effect of these agents in BYNB than in other media. These results indicate that the semisolid agar dilution and broth microdilution methods with EMEM or RPMI yield equivalent and reproducible MICs for AMB, 5FC, and FLU but not ITRA and SCH. 相似文献
12.
Comparison of the agar dilution, tube dilution, and broth microdilution susceptibility tests for determination of teicoplanin MICs. 总被引:1,自引:0,他引:1 下载免费PDF全文
The purpose of this study was to evaluate the National Committee for Clinical Laboratory Standards agar dilution, tube dilution, and broth microdilution susceptibility tests for the measurement of teicoplanin MICs. The three standardized tests gave equivalent (within a twofold dilution) results with 98.8 to 99.0% of the 508 gram-positive clinical isolates tested, indicating that either method may be used for teicoplanin MIC determination. 相似文献
13.
Comparison of sensititre broth microdilution and agar dilution susceptibility testing techniques for meropenem to determine accuracy, reproducibility, and predictive values. 下载免费PDF全文
The stability, accuracy, reproducibility, and predictive value of Sensititre MIC panels containing meropenem (Merrem) were evaluated by using National Committee for Clinical Laboratory Standards (NCCLS)-recommended American Type Culture Collection (ATCC) strains and 110 selected strains of rapidly growing and fastidious aerobes and anaerobes with various degrees of susceptibility to meropenem. The NCCLS-recommended agar dilution method was used as a standard reference method. Meropenem-containing Sensititre MIC panels were monitored for their stabilities at room temperature and reproducibilities over 24 months by using six ATCC strains. Ninety-nine percent of the MICs of both meropenem and imipenem obtained for NCCLS-recommended ATCC strains were within the established ranges after 2 years. The overall agreement (+/- 1 twofold dilution) between the Sensititre and the agar dilution meropenem MICs was greater than 93%. The predictive value of meropenem MICs for indicating suspeptibility or resistance obtained by the Sensititre method was greater than 90%. No major or very major interpretive errors were observed, and only 5% of meropenem MICs were associated with minor interpretive errors. Problematic organisms were not observed. The Sensititre MIC panels containing meropenem offer a convenient and valid alternative to the NCCLS reference method for the susceptibility testing of potential pathogens likely to be recovered from mixed infections. 相似文献
14.
Use of Haemophilus test medium for broth microdilution antimicrobial susceptibility testing of Streptococcus pneumoniae. 总被引:1,自引:4,他引:1 下载免费PDF全文
A recently described medium (Haemophilus test medium [HTM]) for antimicrobial susceptibility testing of Haemophilus influenzae was evaluated in this study for broth microdilution testing of Streptococcus pneumoniae. A total of 137 clinical isolates was tested against 11 antimicrobial agents, using Mueller-Hinton broth supplemented with 3% lysed horse blood in parallel with HTM. Inocula of 5 X 10(5) CFU/ml and incubation for 20 to 24 h were used with both media. All isolates of S. pneumoniae produced acceptable growth in both media, and MICs determined in HTM agreed closely with those determined in lysed horse blood. Drugs which provided a MIC within 1 log2 concentration difference in both media included penicillin (100%), ampicillin (98.0%), amoxicillin-clavulanate (100%), ampicillin-sulbactam (100%), cephalexin (98.9%), cefaclor (96.8%), cefuroxime (99.0%), chloramphenicol (96.2%), tetracycline (96.2%), and erythromycin (100%). HTM MICs with trimethoprim-sulfamethoxazole were 1 to 2 log2 concentration increments higher in 92.0% of isolates than MICs determined in lysed horse blood. Based on the results of this study, HTM appears to represent a promising alternative medium for broth microdilution susceptibility testing of S. pneumoniae. 相似文献
15.
Espinel-Ingroff A 《Journal of clinical microbiology》2003,41(1):403-409
The NCCLS M38-A document does not describe guidelines for testing caspofungin acetate (MK-0991) and other echinocandins against molds. This study evaluated the susceptibilities of 200 isolates of Aspergillus fumigatus, A. flavus, A. nidulans, A. niger, and A. terreus to caspofungin (MICs and minimum effective concentrations [MECs]) by using standard RPMI 1640 (RPMI) and antibiotic medium 3 (M3), two inoculum sizes (10(3) and 10(4) CFU/ml), and two MIC determination criteria (complete [MICs-0] and prominent growth inhibition [MICs-2]) at 24 and 48 h. Etest MICs were also determined. In general, caspofungin MIC-2 and MEC pairs were comparable with both media and inocula (geometric mean ranges of MECs and MICs, respectively, with larger inoculum: 0.12 to 0.64 microg/ml and 0.12 to 0.44 microg/ml with RPMI versus 0.04 to 0.51 microg/ml and 0.03 to 0.21 microg/ml with M3); however, MEC results were less influenced by testing conditions than MICs, especially with the larger inoculum. Overall, the agreement between caspofungin Etest MICs and broth dilution values was higher with MECs obtained with M3 (>90%) and the large inoculum than under the other testing conditions. Because RPMI is a more stable and chemically defined medium than M3, the determination at 24 h of the easier visual MECs with RPMI and the inoculum recommended in the M38-A document appears to be a suitable procedure at present for in vitro testing of caspofungin against Aspergillus spp. Future in vitro correlations with in vivo outcome of both microdilution and Etest procedures may detect more-relevant testing conditions. 相似文献
16.
Comparison of agar dilution, broth microdilution, disk diffusion, E-test, and BACTEC radiometric methods for antimicrobial susceptibility testing of clinical isolates of the Nocardia asteroides complex. 总被引:2,自引:0,他引:2 下载免费PDF全文
A Ambaye P C Kohner P C Wollan K L Roberts G D Roberts F R Cockerill rd 《Journal of clinical microbiology》1997,35(4):847-852
An evaluation was undertaken to determine the optimal method for the in vitro susceptibility testing of 26 Nocardia asteroides complex isolates to the following antimicrobial agents: amikacin, ampicillin, amoxicillin-clavulanate, ceftriaxone, ciprofloxacin, erythromycin, imipenem, minocycline, and trimethoprim-sulfamethoxazole. Five testing methods were studied including the agar dilution, broth microdilution, and disk diffusion methods, the epsilometer test (E-test), and the BACTEC radiometric method. Results for each antimicrobial agent and each testing method were interpreted as indicating susceptibility, intermediate susceptibility, or resistance according to current guidelines of the National Committee for Clinical Laboratory Standards (NCCLS) for bacteria that grow aerobically and were then compared to a "gold standard" susceptibility test result. The gold standard result for each Nocardia isolate was established by a consensus of the results of the majority of testing methods used in the study. When the results were combined for all antimicrobial agents tested against all Nocardia isolates by all methods, the BACTEC radiometric method produced the highest level of agreement (97.9%) with the consensus results and had the fewest very major (n = 1), major (n = 2), and minor (n = 2) errors. In contrast, the results of the agar dilution method were in least agreement (93.2%) with the consensus results, and this method also produced the most very major (n = 8), major (n = 4), and, along with the disk diffusion method, minor (n = 6) errors. For all test methods, interpretive errors were most frequent when testing ampicillin or amoxicillin-clavulanate. Moreover, for all Nocardia nova isolates tested, ampicillin susceptibility results by any of the testing methods were not in agreement with the results of testing for beta-lactamase by the nitrocefin (Cefinase) disk method. We conclude that among the methods evaluated, the BACTEC radiometric method appeared to be the best for determining the in vitro susceptibilities of members of the N. asteroides complex to a panel of nine antimicrobial agents. However, none of the test methods, including the BACTEC method, accurately predicted the ampicillin resistance of the N. nova isolates tested, all of which produced beta-lactamase. Presuming that this beta-lactamase hydrolyzes ampicillin, this disparity may relate to the NCCLS breakpoints that were used, which may require modification for this antimicrobial agent when tested against N. nova isolates. 相似文献
17.
Comparison of E test and agar dilution for antimicrobial susceptibility testing of Stenotrophomonas (Xanthomonas) maltophilia. 总被引:2,自引:0,他引:2 下载免费PDF全文
J D Yao M Louie L Louie J Goodfellow A E Simor 《Journal of clinical microbiology》1995,33(5):1428-1430
Currently recommended dilution test methods for the determination of antimicrobial susceptibility of Stenotrophomonas (Xanthomonas) maltophilia are labor-intensive and often impractical in many clinical laboratories. We compared the E test with the agar dilution method for susceptibility testing of 176 clinical isolates of S. maltophilia against 16 antimicrobial agents. The MICs obtained by E test correlated well with those determined by the agar dilution method, with an overall agreement of 94%. Very major and major errors occurred infrequently (0.6 to 2.9%) when testing beta-lactam agents, tobramycin, trimethoprim-sulfamethoxazole, and fluoroquinolones. The E test was found to be accurate and easy to perform. For most antimicrobial agents tested against S. maltophilia, the E test is an acceptable alternative susceptibility test method. 相似文献
18.
Two-site comparison of broth microdilution and semisolid agar dilution methods for susceptibility testing of Cryptococcus neoformans in three media. 下载免费PDF全文
E Anaissie R Shawar V Paetznick L G Ensign Z Witte M LaRocco 《Journal of clinical microbiology》1993,31(5):1370-1372
This study evaluated the inter- and intralaboratory agreement between results of the semisolid agar dilution and broth microdilution methods of antifungal susceptibility testing of Cryptococcus neoformans. Three media were tested in two laboratories. The drugs tested were amphotericin B, flucytosine, itraconazole, fluconazole, and Schering 39304. Analysis by kappa statistics revealed good agreement between the laboratories for the two methods. The highest level of inter- and intralaboratory agreement was observed in RPMI 1640 with L-glutamine followed by Eagle's minimum essential medium and yeast nitrogen broth. The broth microdilution method appears more suitable than the semisolid agar dilution method for testing cryptococci because of its ease in performance, cost, and simplicity. 相似文献
19.
Zhang SX Rawte P Brown S Lo S Siebert H Pong-Porter S Low DE Jamieson FB 《Journal of clinical microbiology》2011,49(2):704-706
Both the CLSI agar dilution method and Trek Sensititre broth microdilution panel for Streptococcus pneumoniae antimicrobial susceptibility testing were evaluated against the reference CLSI broth microdilution method using the most recently published CLSI breakpoints. While agar dilution was not an optimal method, the commercial panel appeared to be an acceptable method, with minor errors encountered for ceftriaxone, penicillin, and meropenem. 相似文献
20.
Agar dilution and microdilution (both in air) and E test and disk diffusion (both in air and CO(2)) were used to test the activity of telithromycin against 110 erythromycin-susceptible and 106 erythromycin-resistant pneumococci. The MICs at which 50 and 90% of strains are inhibited (MIC(50)s and MIC(90)s, respectively) for erythromycin-susceptible strains varied between 0.008 and 0.016 microg/ml and 0.016 and 0.03 microg/ml when the samples were incubated in air. By comparison, telithromycin MIC(50)s and MIC(90)s for erythromycin-resistant strains were in air 0.03 to 0.125 and 0. 125 to 0.5 microg/ml, respectively. When agar dilution was used as the reference method, essential agreement was found for 112 of 216 strains (51.9%) for microdilution, 168 of 216 (77.8%) for E test in air, and 132 of 216 (61.1%) for E test in CO(2). With the exception of four strains tested by E test in CO(2), all organisms were susceptible to a proposed telithromycin susceptibility breakpoint of < or =1 microg/ml. By disk diffusion with 15-microg telithromycin disks, all strains but one had zones of inhibition > or =19 mm in diameter when incubated in CO(2), while all strains had zone diameters of > or = 22 mm when incubated in air. Zone diameters in air were generally 4 to 5 mm larger than in CO(2). By all methods, MICs and zones of all erythromycin-resistant strains occurred in clusters separated from those seen with erythromycin-susceptible strains. The results for macrolide-resistant strains with erm and mef resistance determinants were similar. The results show that (i) telithromycin is very active against erythromycin-susceptible and -resistant strains irrespective of macrolide resistance mechanism; (ii) susceptibility to telithromycin can be reliably tested by the agar, microdilution, E test, and disk diffusion methods; and (iii) incubation in CO(2) led to smaller zones by disk diffusion and higher MICs by E test, but at a susceptible MIC breakpoint of < or =1 microg/ml and a susceptible zone diameter cutoff of > or =19 mm in CO(2), 215 of 216 strains were found to be susceptible to telithromycin. 相似文献