首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
This work presents histological analysis of interfaces between bone and heteroplastic implants in dog tibias. The study was performed in four tibias (of four mongrel dogs) into which cylindrical implants were inserted. One ceramic (titania) implant and three grit-blasted titanium implants (with sandblasted and acid-corroded surfaces) were chosen for histological analysis of the implant surface/bone tissue interface. The implants remained in the tibias for eight months and none were loaded during this period. The animals were subsequently sacrificed and the samples were processed for analysis. Light microscope analysis revealed a large amount of osteoid tissue and proximity of osteoblasts and osteocytes to the implant surfaces. In addition, little or no fibrous tissue was observed between the bone and implant surfaces. The titanium implants presented better osseointegration than did the ceramic implant.  相似文献   

2.
The effect of a new three-step anodic spark deposition process, labeled TiSpark, including two consecutive treatments performed first in a P solution and second in Ca solution, followed by an additional alkali etching step, was investigated for the improvement of osseointegration of commercial grade 2 titanium, machined (Ti) or Al(2)O(3) sandblasted (Ti-SA), cylindrical implants (12 mm in length and 4 mm in diameter) in cortical bone of 12 adult sheep. Histomorphometric and microhardness measurements were carried out at each experimental time (4, 8, and 12 weeks) to quantify the bone-to-implant contact around the implants as well as the newly bone hardness and bone maturation index. TiSpark treated surfaces were covered by a thick layer of crystalline anatase TiO(2) and by a further Ca/P layer. Bone tissue extends and grows on the surface of the TiSpark treated implants without any fibrous tissue, enhancing the short-term osseointegration properties of implant. Bone mineralization rate was also influenced by the chemical composition of implants and sandblasted materials presented the lowest bone maturation rate at the interface. Data suggests that the TiSpark treatment produces a modification of the Ti surface, which presents good bioactivity and may be suitable for achieving a stable implant osseointegration.  相似文献   

3.
The aim of the present study was to analyze the in vivo effect of biomimetic calcium phosphate coating of titanium implants on periimplant bone formation and bone-/implant contact. Five types of implants were used: 1) Ti6Al4V implants with a polished surface; 2) Ti6Al4V implants with collagen coating; 3) Ti6Al4V implants with a mineralized collagen layer; 4) Ti6Al4V implants with sequential coating of hydroxyapatite (HA) and collagen; and 5) Ti6Al4V implants with HA coating only. All implants had square cross sections with an oblique diameter of 4.6 mm and were inserted press fit into trephine burr holes of 4.6 mm in the mandibles of ten beagle dogs. The implants of five animals each were evaluated after a healing period of 1 month and 3 months, respectively, during which time sequential fluorochrome labeling of bone formation had been performed. Bone formation was evaluated by morphometric measurement of the newly formed bone around the implants and the percentage of implant bone contact. After 1 month, there was a significantly higher percentage of mean bone/implant contact in the HA-coated implants compared to those with polished surface and those with the collagen-coated surface. After 3 months, these differences were not present anymore. Bone apposition was significantly higher next to implants with sequential HA/collagen coating compared to polished surfaces and mineralized collagen layer. It is concluded that biomimetic coating of titanium implants with HA has shown the clearest trend to increase bone-implant contact in the early ingrowth period. The addition of collagen to an HA coating layer may hold some promise when used as sequential HA/collagen coating with mineralized collagen as the surface layer.  相似文献   

4.
Primary stability and an optimized load transfer are assumed to account for an undisturbed osseointegration process of implants. Immediate loaded newly designed titanium dental implants inserted in the mandible of minipigs were used for the characterization of the interfacial area between the implant surface and the surrounding bone tissue during the early healing phase. Histological and electron microscopical studies were performed from implant containing bone specimens. Two different load regimens were applied to investigate the load related tissue reaction. Histological and electron microscopical analysis revealed a direct bone apposition on the implant surfaces, as well as the attachment of cells and matrix proteins in the early loading phase. A striking finding of the ultrastructural immunocytochemical investigations was the synthesis and deposition of bone related proteins (osteonectin, fibronectin, fibronectin receptor) by osteoblasts from day one of bone/biomaterial interaction. Calcium-phosphate needle-like crystallites were newly synthesized in a time-related manner directly at the titanium surface. No difference in the ultrastructural appearance of the interface was found between the two loading groups. Our experimental data suggest that loading of specially designed implants can be performed immediately after insertion without disturbing the biological osseointegration process.  相似文献   

5.
The early interface reaction of cancellous bone to a nanocrystalline hydroxyapatite (HA) cement containing 3 wt% collagen type I (HA/Coll) with a setting under physiological temperature and pH was observed using immunohistochemical techniques. Pure HA served as a control. Cylinders with a diameter of 2 mm were implanted into the proximal tibia of 72 adult Wistar rats. Histological sections of 6 animals were prepared after 1, 2, 4, 6, 14 and 28 days. First, osteoblast-like cells as well as a marked reaction for osteonectin, osteopontin and its ligand CD44 were observed as early as 2 days after implantation at the interface around HA/Coll implants. Further, reactivity for ED1 and cathepsin D, both markers for phagocytotic cells, appeared earlier and stronger around HA/Coll. In cell counts, a significantly higher average number of ED1- and cathepsin D-positive phagocytotic cells was observed around the HA/Coll implants on days 6 (p < 0.01), 14 and 28 (p < 0.05). The number of osteopontin-positive cells was significantly higher around HA/Coll implants at days 6 and 14 (p < 0.05). Two weeks after the implantation, first islands of newly formed woven bone were observed around the HA/Coll implant, but not around the control implant. The amount of direct bone contact after 28 days averaged 28% around pure HA and 51% around HA/Coll implants (p < 0.05). While both implants displayed a good osteoconductivity, a higher bone remodelling activity was observed around collagen-containing HA implants compared to pure HA implants. It appears that the addition of collagen to HA implants can enhance both phagocytotic and osteogenic processes. This may result in an earlier acceptance and better osseointegration of the HA/Coll implants into the surrounding tissue.  相似文献   

6.
The objective of this study is to investigate soft tissue and bone tissue reaction to titanium implants treated by a modified micro arc oxidation (MAO) technique, and analyze the surface components and implant-bone contact ratio by animal experiments to evaluate the osseointegration condition of implants with this modified MAO surface. MAO titanium plates were installed subcutaneously in rabbits. Tissue reaction was evaluated by HE sections. MAO titanium implants designed for endosseous examination were installed in Beagles' femurs. Bone tissue surrounding implants was analyzed histologically. Surfaces of retrieved implants were observed and examined by SEM and EDX. All procedures were performed under the control of untreated pure titanium implants. Thin homogeneous fibrous envelope could be found without apparent inflammation cells infiltration around the subcutaneously imbedded MAO titanium plates, which was almost same as control group. Fast osteoid deposition comprising high content of calcium, phosphor, carbon, and nitrogen elements was found on the retrieved MAO implant surfaces, while comparatively less amount of carbon and nitrogen elements were found on the retrieved implants of control group. Matured bone tissue comprising bone trabeculae and Haversian canals appeared in 8 weeks, while it took 12 weeks needed to form matured bone tissue in control group. In conclusion, MAO titanium materials shows good biocompatibility and calcium phosphate inducement capability in vivo and could accelerate bone tissue growth and shorten the osseointegration time.  相似文献   

7.
Many materials with differing surfaces have been developed for clinical implant therapy in dentistry and orthopedics. We analyzed the quantity of new bone formed in vivo around calcium-immobilized titanium implants with surfaces modified using pamidronate (PAM), a nitrogen-containing bisphosphonate (N-BP), implants of pure titanium, and titanium implants immobilized with calcium ions. New bone formation was visualized using fluorescent labeling (calcein blue and alizarin complexone) with intravenous injection at 1 and 3 weeks after implantation. After 4 weeks, undecalcified sections were prepared, and new bone formation around the implants was examined by morphometry using confocal laser scanning microscopy images. After 1 week, more new bone formed around the PAM-immobilized implant than around the calcium-immobilized and pure titanium implants. This was also seen with the new bone formation after 3 weeks. After 4 weeks, significantly more new bones were formed around the BP-immobilized implant than around the calcium ion-implanted and pure titanium implants. The new N-BP-modified titanium surface stimulates new bone formation around the implant, which might contribute to the success of implant therapy.  相似文献   

8.
The interface zone between titanium implants and bone is considered at the macroscopic, microscopic, and molecular levels. A high rate of successful dental implants of pure titanium is associated with a very close apposition of the bone to the titanium surface, called osseointegration. At the macroscopic level, osseointegration allows efficient stress transfer from the implant to the bone without abrasion or progressive movement that can take place if a fibrous layer intervenes. At the microscopic level, surface roughness and porosity provide interlocking of the implant and bone tissue which grows into direct contact with titanium. Sections studied in the electron microscope show that calcified tissue can be identified within 50 Å of the implant surface. The interface zone includes a tightly adherent titanium oxide layer on the surface of the implant which may be similar to a ceramic material in relation to tissue response. The five year success rate of 90% in 2895 implants in clinical trials since 1965 is associated with the favorable behavior of bone tissue at the interface zone with pure titanium.  相似文献   

9.
Advances have been achieved in the design and biomechanical performance of orthopedic implants in the last decades. These include anatomically shaped and angle-stable implants for fracture fixation or improved biomaterials (e.g. ultra-high-molecular-weight polyethylene) in total joint arthroplasty. Future modifications need to address the biological function of implant surfaces. Functionalized surfaces can promote or reduce osseointegration, avoid implant-related infections or reduce osteoporotic bone loss. To this end, polyelectrolyte multilayer structures have been developed as functional coatings and intensively tested in vitro previously. Nevertheless, only a few studies address the effect of polyelectrolyte multilayer coatings of biomaterials in vivo. The aim of the present work is to evaluate the effect of polyelectrolyte coatings of titanium alloy implants on implant anchorage in an animal model. We test the hypotheses that (1) polyelectrolyte multilayers have an effect on osseointegration in vivo; (2) multilayers of chitosan/hyaluronic acid decrease osteoblast proliferation compared to native titanium alloy, and hence reduce osseointegration; (3) multilayers of chitosan/gelatine increase osteoblast proliferation compared to native titanium alloy, hence enhance osseointegration. Polyelectrolyte multilayers on titanium alloy implants were fabricated by a layer-by-layer self-assembly process. Titanium alloy (Ti) implants were alternately dipped into gelatine (Gel), hyaluronic acid (HA) and chitosan (Chi) solutions, thus assembling a Chi/Gel and a Chi/HA coating with a terminating layer of Gel or HA, respectively. A rat tibial model with bilateral placement of titanium alloy implants was employed to analyze the bones’ response to polyelectrolyte surfaces in vivo. 48 rats were randomly assigned to three groups of implants: (1) native titanium alloy (control), (2) Chi/Gel and (3) Chi/HA coating. Mechanical fixation, peri-implant bone area and bone contact were evaluated by pull-out tests and histology at 3 and 8 weeks. Shear strength at 8 weeks was statistically significantly increased (p < 0.05) in both Chi/Gel and Chi/HA groups compared to the titanium alloy control. No statistically significant difference (p > 0.05) in bone contact or bone area was found between all groups. No decrease of osseointegration of Chi/HA-coated implants compared to non-coated implants was found. The results of polyelectrolyte coatings in a rat model showed that the Chi/Gel and Chi/HA coatings have a positive effect on mechanical implant anchorage in normal bone.  相似文献   

10.
For the last 15 years, orthopedic implants have been coated with hydroxyapatite (HA) to improve implant fixation. The osteoconductive effect of HA coatings has been demonstrated in experimental and clinical studies. However, there are ongoing developments to improve the quality of HA coatings. The objective of this study was to investigate whether a rough and highly crystalline HA coating applied by vacuum plasma spraying (VPS) had a positive effect on the osseointegration of special, high-grade titanium (Ti) implants with the same surface roughness. Ti alloy implants were coated (VPS) with special, high-grade Ti or HA. The osseointegration of the implants was evaluated by either light microscopy or pullout tests after 1, 2, and 4 weeks of unloaded implantation in the cancellous bone of 18 sheep. The interface shear strength increased significantly over all time intervals. By 4 weeks, values had reached approximately 10N/mm(2). However, the difference between the coatings was not significant at any time interval. Direct bone-implant contact was significantly different between the coatings after 2 and 4 weeks, and reached 46% for Ti and 68% for HA implants by 4 weeks. This study indicates that the use of a rough and highly crystalline HA coating, applied by VPS, enhances early osseointegration. Accelerated establishment of secondary implant fixation decreases the risk of early loosening.  相似文献   

11.
Introduction: Oxytocin (OT) was reported to control differentiation of human mesenchymal stem cells and reverse osteoporosis (OP). This study investigated the effect of systematical treatment of OT on implant osseointegration in ovariectomized (OVX) rats. Material and methods: Twenty female rats received bilateral ovariectomy. Twelve weeks later, all animals were randomly assigned to control or experimental group. Each rat received two implants at the distal femoral metaphysis. From the first postoperative day, rats in experiment group received subcutaneous injection of OT (1 mg/kg · d), while animals in control group received vehicle. Twelve weeks after implantation, specimens containing implants were harvested and evaluated by histology, micro-CT, and push-out test. Tibiae were also harvested to evaluate the effect of OT on intact bone tissue of OVX rats. Results: Compared with control, OT treatment increased the relative bone volume surrounding the implant by 2.2 times, the percent implant osseointegration by 0.62 times, and the maximum push-out force by 2.25 times. Increased bone mass was also observed in histological sections of distal femur with implant and intact bone tissue of the proximal tibiae. Conclusion: Systemic administration of OT promoted peri-implant bone healing and osseointegration of titanium implant and recovered the negative effects of OP in undisturbed bone tissue partially.  相似文献   

12.
Identically prepared, screw-type ceramic and titanium endosteal dental implants were inserted in the jaws of adult mongrel dogs for periods of up to 6 months. Sixteen of the 32 total implants supported fixed bridgework. The interface of bone and soft connective tissues with the dental implants was examined by routine and innovative scanning electron microscopic (SEM) techniques using both secondary and backscattered electron imaging. Results demonstrated excellent bone adaptation to both titanium and ceramic implants. Direct adaptation of bone to the upper third of both type implants was observed with only minimal amounts of any intervening fibrous connective tissue. A composite of trabecular bone and fibrous connective tissue was observed in the lower two-thirds of the implants examined. Areas of bone alteration suggestive of osteoid were observed at the thread apicis of some loaded implants. From this investigation we concluded that similar longitudinal tissue responses were generated to one-piece, cylindrical screw-type titanium and alpha alumina oxide ceramic dental implants. Possible bone remodeling was observed at the thread apicis of the loaded implants, an area where occlusal forces may be distributed. We further suggest that one-stage endosteal implants are capable of maintaining a proportional bone-to-implant interface at the apical support region, similar to that suggested to two-stage implant systems.  相似文献   

13.
This study determined the effects of a plasma-sprayed hydroxyapatite/tricalcium phosphate (HA/TCP) coating on osseointegration of plasma-sprayed titanium alloy implants in a lapine, distal femoral intramedullary model. The effects of the HA/TCP coating were assessed at 1, 3, and 6 months after implant placement. The HA/TCP coating significantly increased new bone apposition onto the implant surfaces at all time points. The ceramic coating also stimulated intramedullary bone formation at the middle and distal levels of the implants. Fluorescent bone labeling indicated that new bone formation occurred primarily during the first 3 months after implantation, with comparatively little activity detected in the latter stages of the study. There was no associated increase in pullout strength at either 3 or 6 months; however, post-pullout evaluation of the implants indicated that the HA/TCP coating itself was not the primary site of construct failure. Rather, failure was most commonly observed through the periprosthetic osseous struts that bridged the medullary cavity. The demonstrated osteoconductive activity of HA/TCP coating on plasma-sprayed titanium alloy implant surfaces may have considerable clinical relevance to early host-implant interactions, by accelerating the establishment of a stable prosthesis-bone interface.  相似文献   

14.
Total hip replacement surgery is being performed on an increasingly large part of the population and at increasingly younger age. Because we live and stay physically active longer, and since hip replacement surgery has become quite successful, the treatment is being offered to progressively more patients. Unfortunately, about 17% of hip replacement surgeries currently involve revisions. Consequently, the longevity of both the primary and revision implant is an issue and warrants further investigation. Implants undergoing early instability or even subsidence correlate with an increased risk of aseptic loosening, subsequently requiring revision. Thus, the goal is early fixation by osseointegration of the implant. For revision implants, this is an even greater challenge since an allograft is often needed during surgery to obtain immediate stability of the implant. Bone grafts are rapidly resorbed. Thus, instability of the prosthesis may develop before new bone formation is well established and can mechanically secure the prosthesis. Strontium is a dual action drug; being both bone anabolic and anti-catabolic. In the form of strontiumranelate, it is used in the treatment of osteoporosis. Strontium may potentially improve the early osseointegration and fixation of implants. This dissertation consists of three studies investigating the effect of strontium at the bone-implant interface. The questions were firstly, what is the optimal delivery method for strontium to the interface, and secondly, can strontium exercise its dual action at the interface? The studies were performed in a cementless, experimental gap model in canine. The effects of strontium were evaluated by histomorphometrical analysis of the osseointegration and mechanical push-out test of implant fixation. Different stereological methods were used for the histomorphometrical analysis of each study. The methods used were reviewed critically and found valid. Study I compared a 5% strontium-substituted hydroxyapatite (HA) coating with an HA coating after 4 weeks and 12 weeks observation time. We examined whether fixation of the implant was improved by the strontium substitution. It was found that fixation of the implant was not improved by the strontium substituted HA coating at any of the two time points. Study II compared a 5% strontium-doped HA bone graft extender with an HA bone graft extender. The bone graft extender was mixed with allograft and impacted around a titanium implant. The objective of this study was to determine whether strontium doping of the bone graft extender could protect the allograft from fast resorption and increase gap healing, leading to the improved fixation of the implant. We found that the strontium doping increased gap healing and protected the allograft, however, results of the mechanical test were inconclusive. The reason might have been that the increased gap healing had not yet reached the implant during the 4 weeks observation time, so ongrowth onto the implant was not improved. Study III investigated the effects of bioactive glass coating with a 0%, 10% or 50% strontium-substitution versus HA coating of grit-blasted titanium alloy implants. The goal was to determine whether fixation of the implant would be improved by the bioactive glass coating, and then further improved by the strontium-substitution of the coating in a dose-dependent manner. Unfortunately, the bioactive glass coating failed, presumably due to aluminum contamination originating from the grit-blasting powder. The HA coated implants were superior in all parameters of osseointegration and the mechanical fixation of the implants. These studies show the importance of performing further experimental investigation. Even when investigating a known agent for use in a new application. Strontium delivered as doping of an HA bone graft extender showed potential as a dual acting agent in the interface. However, delivery methods of strontium to the bone-implant interface clearly need further investigation.  相似文献   

15.
It was the purpose of this study to examine the osseointegration of laser-textured titanium alloy (Ti6Al4V) implants with pore sizes of 100, 200, and 300 microm, specifically comparing 200-microm implants with polished and corundum-blasted surfaces in a rabbit transcortical model. Using a distal and proximal implantation site in the distal femoral cortex, each animal received all four different implants in both femora. The bone-implant interface and the newly formed bone tissue within the pores and in peri-implant bone tissue were examined 3, 6, and 12 weeks post-implantation by static and dynamic histomorphometry. Here we show that additional surface blasting of laser-textured Ti6Al4V implants with 200-microm pores resulted in a profound improvement in osseointegration, 12 weeks postimplantation. Although lamellar bone formation was found in pores of all sizes, the amount of lamellar bone within pores was linearly related to pore size. In 100-microm pores, bone remodeling occurred with a pronounced time lag relative to larger pores. Implants with 300-microm pores showed a delayed osseointegration compared with 200-microm pores. We conclude that 200 microm may be the optimal pore size for laser-textured Ti6Al4V implants, and that laser treating in combination with surface blasting may be a very interesting technology for the structuring of implant surfaces.  相似文献   

16.
We compared early fixation of titanium implants grafted with impacted allograft bone or coralline hydroxyapatite (HA) granules (Pro Osteon 200) with and without the addition of concentrated bone marrow cells (BMC). Autologous bone marrow aspirate was centrifuged to increase the BMC concentration. Four nonloaded cylindrical, porous coated titanium implants with a circumferential gap of 2.3 mm were inserted in the proximal humeri of eight dogs. Coralline HA granules +/- BMC were impacted around the two implants on one side, and allograft +/- BMC was impacted around the contra lateral implants. Observation time was 4 weeks. The implants surrounded by allograft bone had a three-fold better fixation than the HA-grafted implants. The concentration of BMC after centrifugation was increased with a factor 2.1. The addition of BMC to either of the bone graft materials had no statistically significant effects on implant fixation. The allografted implants were well osseointegrated, whereas the HA-grafted implants were largely encapsulated in fibrous tissue. The addition of concentrated autologous BMCs to the graft material had no effect on implant fixation. The HA-grafted implants were poorly anchored compared with allografted implants, suggesting that coralline HA granules should be considered a bone graft extender rather than a bone graft substitute.  相似文献   

17.
Improved fixation and increased longevity are still important performance criteria in the development of orthopaedic prostheses. The osseointegration of a series of implant designs made of conventional cobalt-chromium alloy was investigated, the shape of each implant being the critical variable. The shape was defined by computer-aided design with a view to maximising interdigitation of new bone with the implant. Two different process routes, conventional casting and selective laser sintering were employed, each process yielded implants that had identical surface topology but different microstructures. Hydroxyapatite (HA) was used to coat some samples by plasma spraying. Bone formation associated with each implant design was delineated through the administration of fluorescent vital dyes at three time points following their implantation into New Zealand white rabbits. After one month, specimens were harvested, resin embedded, serial sectioned and examined under fluorescent light microscopy. The amount of bone growth was quantified using image analysis. Plasma spray HA-coated samples promoted better osteogenesis and integration than uncoated samples. The extent of bone growth associated with identically shaped specimens fabricated by the SLS route was markedly greater, attributed to the microstructure of these implants.  相似文献   

18.
A study was designed to investigate the osseointegration of titanium implants, either noncoated or coated with hydroxyapatite (HA), into rabbit tibiae in the presence of local infection compared with osseointegration in the absence of local infection. HA-coated or noncoated Ti cylinders were implanted into both tibiae of 32 rabbits (New Zealand Whites). Before implantation the left tibia was contaminated with different quantities of Staphylococcus aureus (10(2)-10(5) CFU). Four weeks after surgery the tibiae were explanted and prepared for microbiological and histomorphometrical examination. Histomorphometrical data, as a representation of implant fixation, were obtained by measuring the percentage of bone around the implants (within a radius of 1 mm from the outer diameter of the implants) and the percentage of the circumference of the implant that was in direct contact with bone. Histomorphometry revealed, in particular for the HA implants, a relationship between the inoculum concentration and/or the presence or absence of infection with the bone contact at the distal implant side. This confirms a relationship between peri-implant infection and bone contact or remodeling. HA-coated implants developed, in the presence of bacteria, more easily a more severe infection than noncoated Ti implants, and we show in the present study that local infection will influence histomorphometrical parameters (bone-implant contact) that determine implant fixation. Precautions to prevent contamination (asepsis) and/or infection (perioperative antibiotics) are even more important for the highly biocompatible HA-coated implant.  相似文献   

19.
Loaded prestressed implants of dense hydroxyapatite and non-loaded hydroxyapatite-coated titanium implants were placed in edentulous regions of the lower jaw of dogs. After 6 month the jaw specimens were fixed and embedded in methyl-methacrylate. Thin non-decalcified ground sections were made for histology. Although the hydroxyapatite showed histological differences between the coated implants and the prestressed solid ones, both had an extensive apposition of normal lamellar bone on the whole surface of the bone-buried part of the implant. The bone contact was very intimate and without any visible intermediate tissue layer. The tissue response observed forms a good biological base for the clinical application of hydroxyapatite-coated titanium implants.  相似文献   

20.
Osseointegration is regarded as the most appropriate implant‐bone interface in dental implantation. However, damaged bone with empty osteocytic lacunae driven by implant cavity preparation remains even after the completion of osseointegration. Although previous studies have suggested the occurrence of bone remodeling around implants, information on its detailed process is meager. Our study aimed to examine the fate of bone around titanium implants after the establishment of osseointegration on an animal model using the rat maxilla. Titanium implants were inserted into prepared bone cavities of the rat maxilla. Bone formation and maturation processes were evaluated by double staining for alkaline phosphatase and tartrate‐resistant acid phosphatase, immunohistochemistry for bone matrix proteins, vital staining with calcein, and elemental mapping with an electron probe microanalyzer. Bone with empty osteocytic lacunae or pyknosis remained between the intact preexisting and newly formed woven bones at post 1 month. It gradually decreased to disappear completely by active bone remodeling with a synchronized coordination of alkaline phosphatase‐positive osteoblasts and tartrate‐resistant acid phosphatase‐reactive osteoclasts at post 3 months, thickening to be replaced by compact bone. Dynamic labeling showed two clear lines in the newly formed bone around the implant through this experimental period. Electron probe microanalyzer analysis demonstrated chronologically increased levels of Ca and P in the newly formed bone identical to those in the surrounding bone at post 2.5 months. These findings indicate that continuous bone remodeling after the achievement of osseointegration causes replacement of the damaged bone by compact bone as well as an improvement in bone quality. Anat Rec, 2009. © 2008 Wiley‐Liss, Inc.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号