首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 11 毫秒
1.
2.
Sixteen patients (male: 14, female: 2, 41-72 yrs, mean 57.5 yrs) with OSAS were treated by nCPAP in our hospital since 1987. Respiratory disturbance index ranged from 16.5 to 83.1. The longest apnea duration was 35.0-120.5 seconds before the treatment. Two patients were treated with Sleep Easy III (Respironics Inc.) and others with a home made instruments. nCPAP was set at a pressure of 5 to 10 cm H2O. 12 patients (75%) tolerated the device but 4(25%) did not. Polysomnographic parameters before and after nCPAP therapy were compared. The longest apnea duration was 63.1 +/- 23.5 to 40.9 +/- 27.4 seconds (P less than 0.001) and the lowest saturation oxygen was 55.1 +/- 20.4% to 71.4 +/- 18.6% (P less than 0.05). The sleep structure improved but not significant statistically. One of them used nCPAP at home for more than two. years and showed a good long term effect. We concluded that nCPAP is an effective and safe treatment for OSAS. However, patients may be uncomfortable because of the wearing of the nasal mask during sleep.  相似文献   

3.
BACKGROUND: Obstructive sleep apnea syndrome (OSAS) is related to diurnal sympathetic hyperactivity and increased blood pressure, both factors that are likely to lead to the development of cardiovascular disease. HYPOTHESIS: The study investigated whether 24-h urinary catecholamines would reflect the effect of obstructive sleep apnea on autonomic activity. METHODS: Standard polysomnography was performed in 17 patients with OSAS (age 53.7 +/- 13.5 years, mean +/- standard deviation). The number of apnea/hypopnea episodes per hour of sleep (apnea/hypopnea index [AHI]); number of oxygen desaturation episodes per hour (desaturation index [DSI]); arousals per hour (arousal index); lowest oxygen saturation (lowest SpO2); and percentages of stages 1, 2, 3/4, and rapid eye movement sleep (% stage 1, -2, and -3/4, and % REM, respectively) were measured. Overnight continuous positive airway pressure (CPAP) titration was performed the night after the baseline sleep measurements had been taken. Twenty-four-hour urinary adrenaline and noradrenaline were also examined. RESULTS: During the CPAP treatment, both 24-h urinary adrenaline and noradrenaline were significantly lower compared with natural sleep. Continuous positive airway pressure significantly decreased the AHI, DSI, % stage 1, and arousal index and significantly increased the lowest SpO2. There were no significant differences in % stage 2, % stage 3/4, and % REM between before and during CPAP treatment. Multiple analysis of covariance tests revealed that lowest SpO2 was the most important factor for increasing 24-h urinary noradrenaline levels (F = 4.75, p = 0.048). CONCLUSIONS: One night CPAP treatment could improve autonomic dysfunction. The assessment of 24-h urinary noradrenaline would provide important information for evaluating the effect of CPAP treatment.  相似文献   

4.
In an attempt to identify predictors of long-term compliance with nasal continuous positive airway pressure (CPAP), we reviewed the records of 125 patients with obstructive sleep apnea (OSA) referred to our center for nasal CPAP trials. Severity of sleep apnea, sleep staging, daytime hypersomnolence, effectiveness of nasal CPAP, previous palatal surgery, and adverse reactions were compared in compliant and noncompliant patients. Nineteen patients did not tolerate a nasal CPAP trial in the laboratory or refused home nasal CPAP therapy. Ten patients were unavailable for follow-up. Of the remaining 96 patients, 23 (24 percent) had discontinued therapy, while 73 (76 percent) were still using nasal CPAP at 14.5 +/- 10.7 months (mean +/- SD). There were no statistically significant differences between the compliant and noncompliant patients in baseline apnea plus hypopnea index (AHI), baseline sleep staging, AHI while receiving nasal CPAP, sleep staging while receiving nasal CPAP, or frequency of adverse reactions during therapy. Severe daytime sleepiness was present in 65 of the 73 compliant patients and in 12 of the 23 noncompliant patients (p less than 0.05). Ten of 43 in the compliant group had previous palatal surgery compared with ten of 23 noncompliant patients (p less than 0.05). Our data confirm earlier observations in smaller samples that compliant and noncompliant patients have equally severe sleep apnea and good initial responses to nasal CPAP. Long-term compliance with nasal CPAP may be associated with the severity of daytime hypersomnolence on presentation. Previous palatal surgery was more frequent in patients who did not tolerate long-term nasal CPAP therapy.  相似文献   

5.
Purpose

Patients with obstructive sleep apnea syndrome (OSAS) have been found to exhibit lower serum vitamin D levels, even when the control groups are matched for confounding conditions. However, contradictory studies are also present. This study aimed to compare serum 25-hydroxyvitamin D (25(OH)D) levels between adult patients with OSAS and non-apneic controls and to evaluate the changes in 25(OH)D levels after 3 and 12 months of continuous positive airway pressure (CPAP) therapy.

Methods

The study was comprised of 30 patients with OSAS and 30 controls. Serum 25(OH)D levels were determined at baseline and after 3 and 12 months of CPAP therapy in all patients with OSAS. For analysis, patients with OSAS were divided into subgroups by adherence, with adherence defined as CPAP usage for > 4 h per night on at least 70% of nights.

Results

The 25(OH)D levels were not significantly different between OSAS and control groups at baseline. 25(OH)D levels did not change after 3 and 12 months of CPAP therapy. Patients who were CPAP-adherent showed less reduction in 25(OH)D levels compared with non-adherent ones (21.18 ± 9.3 vs. 12.13 ± 3.8 ng/mL, p = 0.022) after 1 year. The 25(OH)D levels were significantly correlated with higher daily CPAP usage at 3 and 12 months. Mean daily CPAP usage was a significant predictor of serum 25(OH)D levels at 12 months.

Conclusions

Patients with OSAS who demonstrated good CPAP adherence showed significantly higher 25(OH)D levels after 1 year compared with those not adequately using CPAP. Long-term good CPAP adherence and highly daily CPAP usage positively affected 25(OH)D levels in patients with OSAS.

  相似文献   

6.
Continuous positive airway pressure (CPAP) prediction formulas can potentially simplify the treatment of obstructive sleep apnea (OSA). However, they can be difficult to derive and validate. We tested a statistical method to derive and validate a CPAP prediction formula using the same sample population. Seventy-six OSA patients underwent polysomnography and CPAP titration. Anthropometric measures, sleep parameters, and the Epworth sleepiness scale (ESS) were evaluated as predictors. All subsets regression was used to determine the optimum number of variables in the model. The Bayes information criterion was used to find the best-fit model. The model was then evaluated by a tenfold cross-validation procedure. Subjects were obese (BMI 31.3 ± 5.4) and had significant daytime somnolence (ESS 11.9 ± 5). Mean respiratory disturbance index (RDI) was 53.5 ± 31.3. The ESS was not predictive of titrated CPAP. The best-fit model included three variables (CPAPpred = 30.8 + RDI × 0.03 − nadir saturation × 0.05 − mean saturation × 0.2). This model explained 67% of the variance. Our data and the literature suggest that a combination of two to three factors is predictive of titrated CPAP: RDI, oxyhemoglobin saturation, and obesity. Except for RDI, the specific factors vary in each population. A CPAP prediction formula that explains a high proportion of the titrated CPAP variance can be easily derived from parameters measured during the diagnostic work-up of OSA patients using a unique statistical model that allows derivation and validation of the formula in the same test population.  相似文献   

7.
目的:探讨经鼻持续正压通气(nCPAP)治疗对阻塞性睡眠呼吸暂停综合征(OSAHS)患者血压变异性的影响. 方法:采用24 h动态血压监测与多导睡眠(PSG)同步监测的方法,对102例OSAHS受试者按睡眠呼吸暂停紊乱指数(AHI)分为正常对照组、轻度组和中重度组,观察3组患者的血压情况;对中重度组加用nCPAP治疗后,再观察各项指标的改变. 结果:中重度组患者的平均血压水平均高于对照组及轻度组(P<0.01);中重度组患者经nCPAP治疗8周后,血压变异性包括晨峰现象、非杓型血压比例均较治疗前有明显下降(P<0.05). 结论:OSAHS患者的血压有特征性变化,中重度患者接受有效的nCPAP治疗后,不仅纠正了呼吸障碍,也改善了血压变异性及晨峰现象.  相似文献   

8.
Loredo JS  Ancoli-Israel S  Dimsdale JE 《Chest》1999,116(6):1545-1549
STUDY OBJECTIVES: Continuous positive airway pressure (CPAP) therapy has become the treatment of choice for obstructive sleep apnea (OSA). However, the efficacy of CPAP therapy has not been evaluated against a suitable control. We investigated the effectiveness of CPAP therapy in improving sleep quality in patients with OSA. We hypothesized that CPAP improves sleep quality. PATIENTS: Forty-eight CPAP-naive OSA patients were evaluated. None were receiving antihypertensive medications, and none had major medical illnesses. DESIGN: Patients were randomized to receive either CPAP or placebo CPAP (CPAP at an ineffective pressure) for 7 days in a double-blind fashion. Forty-one patients completed the protocol. Sleep quality variables, arousals, sleep arterial oxygen saturation (SaO(2)), and respiratory disturbance index (RDI) were assessed at baseline, after 1 day of treatment, and after 7 days of treatment. Repeated measures analysis of variance was used to evaluate the effects of treatment, time, and the interaction of the two. RESULTS: As expected, CPAP lowered RDI and number of arousals, and increased SaO(2) over time (p = 0.001). Contrary to expectations, both CPAP and placebo CPAP had comparable effects on sleep quality as assessed by sleep architecture, sleep efficiency, total sleep time, and wake after sleep onset time. CONCLUSIONS: This study confirms the effectiveness of CPAP in lowering the number of arousals and the RDI, and in raising SaO(2). However, our data suggest that short-term CPAP is no different than placebo in improving sleep architecture. Further evaluation of the effectiveness of CPAP using a suitable placebo CPAP in prospective randomized studies is needed  相似文献   

9.
10.
BACKGROUND: Patients with obstructive sleep apnea syndrome (OSAS) are subject to an increased cardiovascular morbidity including systemic hypertension. Little is known about the effects of treatment with nasal continuous positive airway pressure (CPAP) on systemic hypertension. METHODS: Automated ambulatory 24-h blood pressure (BP) monitoring was performed in 88 consecutive patients who were referred for evaluation of snoring or suspected OSAS. In addition, the long-term effects of CPAP therapy on 24-h BP were assessed. RESULTS: A total of 62 patients had OSAS and 26 habitual snoring. Patients with OSAS had significantly higher mean arterial BP values than snorers (102.7 +/- 10.7 v 94.0 +/- 10.2 mm Hg; P < .01). Multiple stepwise linear regression analysis disclosed that the degree of systemic hypertension was independently associated with the severity of OSAS as determined by the apnea/hypopnea index (R = 0.43; P < .001), but not with age, body mass index, or smoking habits. Of the 62 patients with OSAS, 52 were treated with CPAP and reevaluated after 9 months. The CPAP resulted in a significant decrease in mean arterial BP (from 103.7 +/- 10.4 to 99.1 +/- 10.8 mm Hg; P < .05). For those patients with systemic hypertension whose BP improved with CPAP therapy, 24-h mean pulse pressure at baseline (r = -0.36; P < .05) as well as average heart rate during the day (r = -0.35; P < .05) turned out as predictors. CONCLUSIONS: Obstructive sleep apnea syndrome contributes, at least in part, to the development of systemic hypertension, and CPAP may improve BP values in treated OSAS patients. Predictors of a beneficial CPAP effect on BP are a high heart rate and a high pulse pressure before treatment.  相似文献   

11.
BACKGROUND: Sympathetic nerve activity is increased in awake and regularly breathing patients with obstructive sleep apnea (OSA). Over time, repetitive hypoxic stress could alter sympathetic chemoreflex function in OSA. METHODS: We determined the responses to acute hypoxia (fraction of inspired oxygen of 0.1, for 5 min), static handgrip exercise, and the cold pressor test (CPT) in 24 patients with OSA (age, 50 +/- 3 years [mean +/- SEM]; apnea-hypopnea index, 47 +/- 6 events per hour) and in 14 age- and weight-matched nonapneic control subjects. Muscle sympathetic nerve activity (MSNA) [peroneal microneurography], BP, and ventilation were monitored. RESULTS: Basal MSNA was higher in OSA patients compared to control subjects (45 +/- 4 bursts per minute vs 33 +/- 4 bursts per minute, respectively; p < 0.05). Furthermore, compared to control subjects, the MSNA responses to hypoxia were markedly enhanced in OSA (p < 0.001). Whereas the ventilatory responses to hypoxia tended to be increased in OSA (p = 0.06), the BP responses did not differ between the groups (p = 0.45). The neurocirculatory reflex responses to handgrip exercise and to the CPT were similar in the two groups (p = not significant). In OSA patients who were retested after 1 to 24 months of continuous positive airway pressure (CPAP) therapy (n = 11), basal MSNA (p < 0.01) and the responses of MSNA to hypoxia (p < 0.01) decreased significantly, whereas the ventilatory responses remained unchanged (p = 0.82). CONCLUSION: These data suggest that the sympathetic responses to hypoxic chemoreflex stimulation are enhanced in OSA and may normalize in part following CPAP therapy.  相似文献   

12.
Compliance with continuous positive airway pressure (CPAP) therapy is one of the most difficult management problems for patients with obstructive sleep apnea (OSA). We postulated that autotitration positive airway pressure (APAP) may be effective in some patients who have an intolerance of fixed CPAP. The study was done to estimate how often patients who cannot tolerate fixed CPAP can tolerate APAP. We identified 25 patients seen in the Sleep Disorders Center who had been treated with fixed CPAP for OSA and were intolerant of CPAP therapy despite multiple efforts to improve tolerance. We substituted APAP therapy and measured subjective and objective compliance with treatment 1 month later. The primary end point was the number of patients who successfully tolerated the use of APAP at the end of 30 days, measured objectively by the device's compliance monitor. A positive outcome was defined as an average use of APAP that was greater than 3 h per night on more than 70% of possible nights. Of the 25 patients (mean age, 68 years; mean apnea-hypopnea index, 35), 11 were able to tolerate APAP therapy. The mean number of hours of use in these responders was 6.2; the mean percentage of nights of use among responders was 89%. Determinants of successful APAP use were an apnea-hypopnea index (AHI) less than 18, male sex, OSA related to rapid eye movement, and a high body mass index. APAP therapy may be an effective option in patients who do not tolerate fixed-CPAP therapy.  相似文献   

13.
Despite the high prevalence of obstructive sleep apnea (OSA) syndrome, no ideal therapy has emerged to date. Based on recent randomized trials, continuous positive airway pressure (CPAP) therapy is the treatment of choice. Although CPAP can prevent pharyngeal collapse in virtually all patients who choose to wear it, poor patient adherence with treatment limits its effectiveness. Although convincing data exist that treatment with CPAP can alleviate the neurocognitive sequelae of OSA, data on cardiovascular complications are more limited. Several recent reports support a lowering of nocturnal and daytime blood pressure with CPAP, but data on the prevention of myocardial infarction and cerebrovascular events are currently lacking. Patient adherence with CPAP can be improved with optimization of mask comfort, heated humidification, and intensive support and education. For those who remain poorly compliant, alternative therapies such as autotitrating devices and oral positive airway pressure can be considered. Further research into the basic mechanisms underlying OSA will be required for new therapeutic targets to develop.  相似文献   

14.
Bazzano LA  Khan Z  Reynolds K  He J 《Hypertension》2007,50(2):417-423
Obstructive sleep apnea (OSA) is a very common risk factor for hypertension, and continuous positive airway pressure (CPAP) has been widely used to treat OSA. We conducted a meta-analysis of randomized, controlled trials to evaluate the effects of CPAP on blood pressure, reported as either a primary or secondary end point, among patients with OSA. Studies were retrieved by searching Medline (January 1980 to July 2006), the Cochrane Database of Systematic Reviews, conference abstracts, and bibliographies of review and original articles. From 255 relevant reports, 16 randomized clinical trials were selected that compared CPAP to control among participants with OSA, had a minimum treatment duration of 2 weeks, and reported blood pressure changes during the intervention or control period. Data on sample size, participant characteristics, study design, intervention methods, duration, and treatment results were independently abstracted by 2 investigators using a standardized protocol. Data from 16 trials representing 818 participants were examined using a random-effects model. Mean net change in systolic blood pressure for those treated with CPAP compared with control was -2.46 mm Hg (95% CI: -4.31 to -0.62); mean net change in diastolic blood pressure was -1.83 mm Hg (95% CI: -3.05 to -0.61); and mean net change in mean arterial pressure was -2.22 mm Hg (95% CI: -4.38 to -0.05). Net reductions in blood pressure were not statistically different between daytime and nighttime. These results indicate that CPAP decreases blood pressure among those with OSA and may help prevent hypertension.  相似文献   

15.
Current resources are inadequate to meet the demand for polysomnography, resulting in long waiting lists. This study aimed to evaluate the role of arbitrary-pressure continuous positive airway pressure (CPAP) as a method to reduce delays in commencing treatment. The study was of an open, randomized, parallel design. Ninety-one subjects with obstructive sleep apnea syndrome were randomized to either arbitrary-pressure CPAP based on body mass index before treatment polysomnography or to CPAP at settings determined by polysomnography. Both interventions resulted in similar improvements in clinical outcomes as determined by Epworth Sleepiness Score, Short Form-36 Quality of Life questionnaire, objective compliance, and subjective attitudes to treatment. There was higher sleep efficiency at treatment polysomnography in the group commenced at arbitrary pressure (81.8 +/- 10.1% [mean +/- SD] compared with 72.2 +/- 18.0%, p = 0.01). Subjects unable to tolerate CPAP were identified by the use of arbitrary pressure, leading to a reduction in the proportion of "wasted" treatment polysomnograms (studies performed in subjects not persisting with treatment) relative to commencing therapy after treatment polysomnography (3 of 39 compared with 12 of 35, p = 0.01). This approach to initiating treatment with CPAP appears feasible when there are long waiting lists for polysomnography.  相似文献   

16.
We studied the long-term acceptability of nasal continuous positive airway pressure (CPAP) treatment in 168 consecutive patients, 147 with obstructive sleep apnea (OSA) and 21 with snoring. Follow-up was between 1.5 and 78 months. At latest follow-up 107 of 168 (64%) were still using CPAP. Acceptance of CPAP was least for patients with snoring alone (6 of 21 persisted) and best for patients with both excessive daytime somnolence and severe hypoxemia (minimum SaO2 less than 75%), of whom 40 of 45 (89%) persisted with treatment. Patients with excessive daytime somnolence but without severe hypoxemia were less tolerant of CPAP (39 of 71, 55%, persisted) than patients with no symptoms of excessive somnolence but with severe hypoxemia (21 of 30, 70%, persisted). The most common reasons for discontinuing CPAP were intolerance of the mask (26 of 61), the inconvenience of treatment (16 of 61), and the lack of symptomatic benefit from treatment (10 of 61). We concluded that long-term acceptance of CPAP was difficult to predict in advance but that it was most likely in patients with the most severe sleep apnea. Because intolerance of the mask and inconvenience were the most common reasons for ceasing treatment, improvements in the design of CPAP systems and careful patient training may improve the acceptability of CPAP substantially.  相似文献   

17.

Background  

Obstructive sleep apnea disease (OSA) is associated with a myriad of endocrine adverse effects. Changes in the serum prolactin (PRL) secretion in OSA are thought to be related to the hypoxic stress and subsequently to result in reversible changes with effective continuous positive airway pressure (CPAP) therapy. Due to current disagreements on this topic, we investigated the effect of CPAP therapy on the serum PRL in patients with OSA, using the most accurate CPAP compliance assessment to date  相似文献   

18.

Background

Patients with obstructive sleep apnea syndrome (OSAS) are at increased risk for cerebrovascular diseases. The underlying mechanisms remain obscure. It may occur through a reduction in cerebral vascular reactivity. Continuous positive airway pressure (CPAP) is effective in reducing the occurrence of apneas. We hypothesized that treatment with CPAP improves cerebral vascular reactivity.

Methods

This is a prospective study with OSAS patients. The apnea test (ApT) was calculated as an increase of mean artery velocity during apnea: [Artery velocity in apnea minus Resting artery velocity]/Resting artery velocity expressed as percentage. After 2 years of CPAP treatment, the test was repeated.

Results

Seventy-six patients represented the study pool. After 2 years of treatment with CPAP, we were able to conduct a reassessment in 65 patients. Of the 65 patients who finished the clinical study, 56 were men, and 9 were women, with an average age of 48.1?±?10.4 years. There was an improvement in the ApT after CPAP treatment (30.8?±?12.1 vs 39.8?±?15.1; p:0.000). The values of cerebral blood flow velocities, diastolic blood pressure in apnea, and basal heart rate decreased.

Conclusions

Cerebral vascular reactivity in OSAS patients measured by ApT improved after 2 years of CPAP.  相似文献   

19.
20.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号