We have developed a coaxial measurement system for determining the time and temperature dependence of the dielectric properties of bovine liver at 915 MHz during heating. Our data suggest that changes in dielectric properties due to heating are dominated by the relaxation response of two tissue components: tissue water and proteins. At temperatures above 60 degrees C, the effects of these two components contribute to increases of up to 100% and 5% in the values of conductivity and permittivity respectively. Changes due to tissue water content were found to be reversible with temperature, while changes due to protein denaturation were found to be permanent. The temperature coefficients for reversible changes were found to be 1.82 +/- 0.28% degrees C(-1) and -0.130 +/- (5.9 x 10(-2))% degrees C(-1) for conductivity and permittivity respectively. The critical temperatures and activation energies leading to irreversible changes in conductivity and permittivity were determined using Arrhenius analysis. Frequency factors of (1.14 +/- 0.27) x 10(43) s(-1) and (1.95 +/- 0.49) x 10(36) s(-1) were determined for permittivity and conductivity respectively. The activation energies were calculated to be 70.7 +/- 15.8 kcal mol(-1) for permittivity and 60.1 +/- 14.0 kcal mol(-1) for conductivity. 相似文献
2.
Swartling J Pålsson S Platonov P Olsson SB Andersson-Engels S 《Medical & biological engineering & computing》2003,41(4):403-409
The optical properties of pig heart tissue were measured after in vivo ablation therapy had been performed during open-heart
surgery. In vitro samples of normal and ablated tissue were subjected to measurements with an optically integrating sphere
set-up in the region 470–900 nm. Three independent measurements were made: total transmittance, total reflectance and collimated
transmittance, which made it possible to extract the absorption and scattering coefficients and the scattering anisotropy
factor g, using an inverse Monte Carlo model. Between 470 and 700 nm, only the reduced scattering coefficient and absorption
could be evaluated. The absorption spectra were fitted to known tissue chromophore spectra, so that the concentrations of
haemoglobin and myoglobin could be estimated. The reduced scattering coefficient was compared with Mie computations to provide
Mie equivalent average radii. Most of the absorption was from myoglobin, whereas haemoglobin absorption was negligible. Metmyoglobin
was formed in the ablated tissue, which could yield a spectral signature to distinguish the ablated tissue with a simple optical
probe to monitor the ablation therapy. The reduced scattering coefficient increased by, on average, 50% in the ablated tissue,
which corresponded to a slight decrease in the Mie equivalent radius. 相似文献
3.
Determination of in vivo optical properties is a challenging problem. Absorption and scattering measured ex vivo are often used for in vivo applications. To investigate the validity of this approach, we have obtained and compared the optical properties of mouse ears in vivo and ex vivo in the spectral range from 370 to 1650 nm. Integrating sphere spectrophotometry in combination with the inverse Monte Carlo technique was employed to determine absorption coefficients, mu(a), scattering coefficients, mu(s), and anisotropy factors, g. Two groups of mice were used for the study. The first group was measured in vivo and ex vivo within 5-10 min post mortem. The second group was measured in vivo and ex vivo every 24 h for up to 72 h after sacrifice. Between the measurements the tissues were kept at 4 degrees C wrapped in a gauze moistened with saline solution. Then the specimens were frozen at -25 degrees C for 40 min, thawed and measured again. The results indicate that the absorption coefficients determined in vivo and ex vivo within 5-10 min post mortem differed considerably only in the spectral range dominated by hemoglobin. These changes can be attributed to rapid deoxygenation of tissue and blood post mortem. Absorption coefficients determined ex vivo up to 72 h post mortem decreased gradually with time in the spectral regions dominated by hemoglobin and water, which can be explained by the continuing loss of blood. Absorption properties of the frozen-thawed ex vivo tissues showed increase in oxygenation, which is likely caused by the release of hemoglobin from hemolyzed erythrocytes. Scattering of the ex vivo tissues decreased gradually with time in the entire spectral range due to the continuing loss of blood and partial cell damage. Anisotropy factors did not change considerably. 相似文献
4.
Zaman RT Rajaram N Nichols BS Rylander HG Wang T Tunnell JW Welch AJ 《Journal of biomedical optics》2011,16(7):077008
Light scattering in the normally white sclera prevents diagnostic imaging or delivery of a focused laser beam to a target in the underlying choroid layer. In this study, we examine optical clearing of the sclera and changes in blood flow resulting from the application of glycerol to the sclera of rabbits. Recovery dynamics are monitored after the application of saline. The speed of clearing for injection delivery is compared to the direct application of glycerol through an incision in the conjunctiva. Although, the same volume of glycerol was applied, the sclera cleared much faster (5 to 10 s) with the topical application of glycerol compared to the injection method (3 min). In addition, the direct topical application of glycerol spreads over a larger area in the sclera than the latter method. A diffuse optical spectroscopy system provided spectral analysis of the remitted light every two minutes during clearing and rehydration. Comparison of measurements to those obtained from phantoms with various absorption and scattering properties provided estimates of the absorption coefficient and reduced scattering coefficient of rabbit eye tissue. 相似文献
5.
6.
When rats were pretreated by intraplantar or i.v. injection of various inflammatory mediators, the vasopressor effect of i.a. norepinephrine in the subsequently isolated perfused hindlegs of the rats was found to be partly depressed. This vasodepression could also be detected if mediators were directly co-perfused in the isolated hindlegs. The vasodepressor effect was strongest following histamine pretreatment and co-perfusion, respectively, whereas endotoxin 0111:B4, PAF-acether, PGE1, and LTD4 were less effective Only weak or no vasodepression could be induced by bradykinin, serotonin, lysolecithin, and substance P(1–11). The significance of the results is discussed with respect to anaphylactic disorders. 相似文献
7.
P M Ripley J G Laufer A D Gordon R J Connell S G Bown 《Physics in medicine and biology》1999,44(10):2451-2462
The optical properties, absorption (mua) and reduced scattering coefficient (mu's), of ex vivo human myometrium and leiomyoma (fibroid) have been determined by the Monte Carlo inversion technique over the wavelength range 600-1000 nm. This region is currently of interest for new, minimal-access, surgical laser procedures such as photodynamic therapy (PDT) for abnormalities of the uterus, and interstitial laser photocoagulation (ILP) for the thermal ablation of fibroids. In the region 630-675 nm (corresponding to PDT), the optical coefficients of myometrium are mua = 0.041+/-0.012 mm(-1) and mu's = 1.37+/-0.19 mm(-1). For the wavelength range 800-1000 nm (associated with infrared lasers for ILP), the optical coefficients of fibroid were found to be mua = 0.020+/-0.003 mm(-1) and mu's = 0.56+/-0.03 mm(-1). Overall, the optical properties of fibroid were found to be lower than myometrium, and this was attributed to the differences in both anatomy and vascularity. The results show that PDT for ablation of the uterine endometrium is most unlikely to affect any tissues beyond the myometrium, and that the region around 800 nm is the most effective for ablation of fibroids using ILP as the penetration depth of light is greatest at this wavelength. 相似文献
8.
In microwave thermal ablation (MTA) therapy, the dielectric properties of the target tissue play an important role in determining the radiation properties of the microwave ablation antenna. In this work, the ex vivo dielectric properties of bovine liver were experimentally characterized as a function of the temperature during MTA at the frequency of 2.45 GHz. The obtained data were compared with measurements performed at the end of the MTA treatment, and considering the heating achieved with a temperature-controlled water bath. Finally, measured data were used to perform a numerical study evaluating the effects of changes in tissue's dielectric properties during the MTA treatment on the radiation properties of a microwave interstitial ablation antenna, as well as on the obtained thermal lesion. Results evidenced a significant decrease of both relative permittivity (about 38%) and electric conductivity (about 33%) in the tissue during treatment as the temperature increased to over 60 °C, with a dramatic drop when the temperature approached 100 °C. Moreover, the numerical study evidenced that changes in tissue's dielectric properties during the MTA treatment affect the distribution of the power absorbed by the tissue (specific absorption rate-SAR, W kg(-1)) surrounding the microwave interstitial ablation antenna, leading to a peak SAR up to 20% lower, as well as to a thermal lesion up to 8% longer. This work may represent a preliminary step towards the future development of a procedure for MTA treatment planning. 相似文献
9.
We apply ultrasound-modulated optical tomography (UOT) to image ex-vivo methylene-blue-dyed sentinel lymph nodes embedded in 3.2-cm-thick chicken breast tissues. The UOT system is implemented for the first time using ring-shaped light illumination, intense acoustic bursts, and charge-coupled device (CCD) camera-based speckle contrast detection. Since the system is noninvasive, nonionizing, portable, relatively cost effective, and easy to combine with photoacoustic imaging and single element ultrasonic pulse-echo imaging, UOT can potentially be a good imaging modality for the detection of sentinel lymph nodes in breast cancer staging in vivo. 相似文献
10.
Optical coherence tomography (OCT) is an emerging medical imaging technology that enables high-resolution, noninvasive, cross-sectional imaging of microstructure in biological tissues in situ and in real time. When combined with small-diameter catheters or needle probes, OCT offers a practical tool for the minimally invasive imaging of living tissue morphology. We evaluate the ability of OCT to image normal kidneys and discriminate pathological changes in kidney structure. Both control and experimental preserved rat kidneys were examined ex vivo by using a high-resolution OCT imaging system equipped with a laser light source at 1.3-microm wavelength. This system has a resolution of 3.3 microm (depth) by 6 microm (transverse). OCT imaging produced cross-sectional and en face images that revealed the sizes and shapes of the uriniferous tubules and renal corpuscles. OCT data revealed significant changes in the uriniferous tubules of kidneys preserved following an ischemic or toxic (i.e., mercuric chloride) insult. OCT data was also rendered to produce informative three-dimensional (3-D) images of uriniferous tubules and renal corpuscles. The foregoing observations suggest that OCT can be a useful non-excisional, real-time modality for imaging pathological changes in donor kidney morphology prior to transplantation. 相似文献
11.
12.
13.
MR elastography and diffusion‐weighted imaging of ex vivo prostate cancer: quantitative comparison to histopathology 下载免费PDF全文
Ramin S. Sahebjavaher Guy Nir Louis O. Gagnon Joseph Ischia Edward C. Jones Silvia D. Chang Andrew Yung Mohammad Honarvar Ladan Fazli S. Larry Goldenberg Robert Rohling Ralph Sinkus Piotr Kozlowski Septimiu E. Salcudean 《NMR in biomedicine》2015,28(1):89-100
The purpose of this work was (1) to develop a magnetic resonance elastography (MRE) system for imaging of the ex vivo human prostate and (2) to assess the diagnostic power of mono‐frequency and multi‐frequency MRE and diffusion weighted imaging (DWI) alone and combined as correlated with histopathology in a patient study. An electromagnetic driver was designed specifically for MRE studies in small‐bore MR scanners. Ex vivo prostate specimens (post‐fixation) of 14 patients who underwent radical prostatectomy were imaged with MRE at 7 T (nine cases had DWI). In six patients, the MRE examination was performed at three frequencies (600, 800, 1000 Hz) to extract the power‐law exponent Gamma. The images were registered to wholemount pathology slides marked with the Gleason score. The areas under the receiver‐operator‐characteristic curves (AUC) were calculated. The methods were validated in a phantom study and it was demonstrated that (i) the driver does not interfere with the acquisition process and (ii) the driver can generate amplitudes greater than 100 µm for frequencies less than 1 kHz. In the quantitative study, cancerous tissue with Gleason score at least 3 + 3 was distinguished from normal tissue in the peripheral zone (PZ) with an average AUC of 0.75 (Gd), 0.75 (Gl), 0.70 (Gamma‐Gd), 0.68 (apparent diffusion coefficient, ADC), and 0.82 (Gd + Gl + ADC). The differentiation between PZ and central gland was modest for Gd (p < 0.07), Gl (p < 0.06) but not significant for Gamma (p < 0.2). A correlation of 0.4 kPa/h was found between the fixation time of the prostate specimen and the stiffness of the tissue, which could affect the diagnostic power results. DWI and MRE may provide complementary information; in fact MRE performed better than ADC in distinguishing normal from cancerous tissue in some cases. Multi‐frequency (Gamma) analysis did not appear to improve the results. However, in light of the effect of tissue fixation, the clinical implication of our results may be inconclusive and more experiments are needed. Copyright © 2014 John Wiley & Sons, Ltd. 相似文献
14.
目的为解决手术中激光切割能力下降的问题,以鸡蛋蛋清为样本,研究热变过程中生物组织的光学特性变化。方法使用积分球系统测量650nm激光照射下的样本在热风枪加热下,从26%升温到99℃过程中的准直透射光、漫透射光和反射光光强随温度变化的数据,计算吸收系数和散射系数变化曲线。结果样本热变前光学特性受温度影响较小,热变过程中透射率降低,吸收系数和散射系数增大。结论手术中低强度激光照射组织发生热变使吸收能力下降,应保持较高激光强度以达到消融阈值。 相似文献
15.
Kim SY Lee H Kim HJ Bang E Lee SH Lee DW Woo DC Choi CB Hong KS Lee C Choe BY 《NMR in biomedicine》2011,24(10):1235-1242
Subanesthetic doses of ketamine, a noncompetitive N‐methyl‐D ‐aspartate (NMDA) receptor antagonist, impair prefrontal cortex (PFC) function in the rat and produce symptoms in humans similar to those observed in patients with schizophrenia. In the present study, in vivo 1H‐MRS and ex vivo 1H high‐resolution magic angle spinning (HR‐MAS) spectroscopy was used to examine the brain metabolism of rats treated with subanesthetic doses of ketamine (30 mg/kg) for 6 days. A single voxel localization sequence (PRESS, TR/TE = 4000/20 ms and NEX = 512) was used to acquire the spectra in a 30‐µl voxel positioned in the cerebral cortex (including mainly PFC) of the rats (ketamine group: n = 12; saline group: n = 12) anesthetized with isoflurane. After the in vivo 1H‐MRS acquisition, the animals were sacrificed and the cerebral cortex tissues were extracted (ketamine group: n = 7; saline group: n = 7) for ex vivo 1H HR‐MAS spectroscopy (CPMG sequence, 2.0‐s presaturation delay, 2.0‐s acquisition time, 128 transients and 4‐ms inter‐pulse delay) using a 500‐MHz NMR spectrometer. All proton metabolites were quantified using the LCModel. For the in vivo spectra, there was a significant increase in glutamate concentration in the cerebral cortex of the ketamine group compared with the controls (p < 0.05). For the ex vivo HR‐MAS spectra, there was a significant increase in the glutamate/total creatine ratio, and a decrease in the glutamine/total creatine and glutamine/glutamate ratios in the cerebral cortex tissue of the ketamine group compared with the controls. The results of the present study demonstrated that administration of subanesthetic doses of ketamine in the rat may exert at least part of their effect in the cerebral cortex by activation of glutamatergic neurotransmission. Copyright © 2011 John Wiley & Sons, Ltd. 相似文献
16.
We develop a superficial diffusing probe with a 3 mm source-detector separation that can be used in combination with diffuse optical spectroscopic (DOS) methods to noninvasively determine full-spectrum optical properties of superficial in vivo skin in the wavelength range from 650 to 1000 nm. This new probe uses a highly scattering layer to diffuse photons emitted from a collimated light source and relies on a two-layer diffusion model to determine tissue absorption coefficient mu a and reduced scattering coefficient mu's. By employing the probe to measure two-layer phantoms that mimic the optical properties of skin, we demonstrate that the probe has an interrogation depth of 1 to 2 mm. We carry out SSFDPM (steady state frequency-domain photon migration) measurements using this new probe on the volar forearm and palm of 15 subjects, including five subjects of African descent, five Asians, and five Caucasians. The optical properties of in vivo skin determined using the superficial diffusing probe show considerable similarity to published optical properties of carefully prepared ex vivo epidermis+dermis. 相似文献
17.
目的 通过膨胀试验测定猪眼角膜的非线性应力/应变关系,研究猪眼角膜弹性模量和眼内压之间的关系。方法 选取新鲜猪眼11只,剪下附带4~5mm宽度巩膜环的角膜,采取胶水黏附联合机械固定方式将猪眼角膜固定于自制的施压装置,缓慢逐步增加液压,液压范围:25mmH2O(1.8375mmHg) ~ 1000mmH2O (73.5mmHg),激光位移计记录角膜前表面顶点的前突位移量,根据板壳理论推导公式计算猪眼角膜的生物力学参数,包括应力、应变及弹性模量。结果 猪眼角膜前突位移量同眼内压的关系及应力/应变均呈指数函数关系,弹性模量与眼内压呈线性关系。结论 膨胀法测量猪眼角膜的弹性模量具有较好的重复性和精确性,此方法所测得的弹性模量可用于后期屈光手术模型的建立、人工角膜与角膜接触镜设计及其它方面的研究。 相似文献
18.
P Li R Reif Z Zhi E Martin TT Shen M Johnstone RK Wang 《Journal of biomedical optics》2012,17(7):076026
Glaucoma is a blinding disease for which intraocular pressure (IOP) is the only treatable risk factor. The mean IOP is regulated through the aqueous outflow system, which contains the trabecular meshwork (TM). Considerable evidence indicates that trabecular tissue movement regulates the aqueous outflow and becomes abnormal during glaucoma; however, such motion has thus far escaped detection. The purpose of this study is to describe anovel use of a phase-sensitive optical coherence tomography (PhS-OCT) method to assess pulse-dependent TM movement. For this study, we used enucleated monkey eyes, each mounted in an anterior segment holder. A perfusion system was used to control the mean IOP as well as to provide IOP sinusoidal transients (amplitude 3 mmHg, frequency 1 pulse/second) in all experiments. Measurements were carried out at seven graded mean IOPs (5, 8, 10, 20, 30, 40, and 50 mm Hg). We demonstrate that PhS-OCT is sensitive enough to image/visualize TM movement synchronous with the pulse-induced IOP transients, providing quantitative measurements of dynamic parameters such as velocity, displacement, and strain rate that are important for assessing the biomechanical compliance of the TM. We find that the largest TM displacement is in the area closest to Schlemm's canal (SC) endothelium. While maintaining constant ocular pulse amplitude, an increase of mean IOP results in a decrease of TM displacement and mean size of the SC. These results demonstrate that the PhS-OCT is a useful imaging technique capable of assessing functional properties necessary to maintain IOP in a healthy range, offering a new diagnostic alternative for glaucoma. 相似文献
19.
20.
Bizheva K Unterhuber A Hermann B Povazay B Sattmann H Fercher AF Drexler W Preusser M Budka H Stingl A Le T 《Journal of biomedical optics》2005,10(1):11006
The ability of ultra-high-resolution optical coherence tomography (UHR OCT) to discriminate between healthy and pathological human brain tissue is examined by imaging ex vivo tissue morphology of various brain biopsies. Micrometer-scale OCT resolution (0.9x2 microm, axialxlateral) is achieved in biological tissue by interfacing a state-of-the-art Ti:Al2O3 laser (lambda(c)=800 nm, delta lambda=260 nm, and P(out)=120 mW exfiber) to a free-space OCT system utilizing dynamic focusing. UHR OCT images are acquired from both healthy brain tissue and various types of brain tumors including fibrous, athypical, and transitional meningioma and ganglioglioma. A comparison of the tomograms with standard hematoxylin and eosin (H&E) stained histological sections of the imaged biopsies demonstrates the ability of UHR OCT to visualize and identify morphological features such as microcalcifications (>20 microm), enlarged nuclei of tumor cells (approximately 8 to 15 microm), small cysts, and blood vessels, which are characteristic of neuropathologies and normally absent in healthy brain tissue. 相似文献