首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到18条相似文献,搜索用时 218 毫秒
1.
目的: 比较宫颈癌根治术后行阴道三维腔内近距离治疗采用单通道柱状、双卵圆球两种施源器的剂量学差异,为宫颈癌术后行阴道三维腔内近距离放疗选择施源器提供参考。方法: 回顾性分析2018年6月12月于川北医学院附属医院肿瘤科完成阴道三维腔内近距离放射治疗的早期宫颈癌术后患者20例,每例患者均在接受宫颈癌根治手术后因有术后放疗指征,进行术后三维腔内近距离放射治疗。每例患者分别采用单通道柱状施源器、双卵圆球施源器行后装治疗各1次,不分先后。利用每例患者放疗时的实际CT定位资料,共40个CT定位资料,按照统一的靶区勾画标准重新勾画靶区(靶体积及危及器官)后制作近距离腔内放射治疗计划。分别统计两种施源器近距离治疗计划中靶区体积、D90、D100和膀胱、直肠体积及其D2cc。 采用独立样本t检验方法比较两种施源器在宫颈癌术后三维近距离治疗中靶区、危及器官剂量。 结果:阴道柱状施源器组和双卵圆球施源器组平均临床靶区体积分别为:(29.56±4.51)cm3、(31.68±3.16 )cm3,差异无统计学意义(P=0.095)。柱状施源器组D90、D100分别为:(611.60±8.70)cGy、(414.38±47.16)cGy;双卵圆球施源器组D90、D100分别为:(608.19±7.30)cGy、(359.54±38.13)cGy,两组CTV D90约为 6Gy,差异无统计学意义(P=0.180);D100差异有统计学意义(P =0.003)。柱状施源器组与双卵圆球施源器组直肠体积分别为:(53.03±10.70)cm3、(52.37±8.87)cm3,差异无统计学意义(P =0.213);直肠D2cc分别为:(375.77±62.10)cGy、(341.57±38.43)cGy,差异有统计学意义(P=0.043);膀胱体积分别为:(129.31±18.90)cm3、(123.14±13.15)cm3,差异无统计学意义(P=0.239);膀胱D 2cc分别为:(391.13±62.94)cGy、(356.42±27.12)cGy,差异有统计学意义(P=0.032)。结论:宫颈癌根治术后阴道三维腔内近距离放射治疗中,与双卵圆球施源器相比,使用单通道柱状施源器靶区剂量分布更优,但膀胱、直肠受照剂量更高。因此在临床上,当直肠膀胱外照射受量较高、副反应较重可选择双卵圆球施源器,反之可选择单通道柱状施源器。  相似文献   

2.
目的 比较单通道和六通道柱状施源器2D、3D治疗计划靶区和正常组织照射剂量,评估三维近距离治疗在子宫内膜癌术后阴道内照射中的应用优势。方法 早期子宫内膜癌10例,分别置入六通道和单通道柱状施源器,CT模拟定位扫描后做治疗计划。CTV定义为阴道上段3 cm,黏膜下5 mm区域,处方剂量为5 Gy/次,共6次。分别制定不同施源器2D和3D治疗计划。比较两种施源器2D与3D计划CTV和OAR的剂量。结果 两种施源器2D、3D治疗计划均能很好满足CTV剂量要求。使用单通道施源器时3D计划可显著降低直肠D0.1 cm3、D1.0 cm3、D2.0 cm3约18.2%、12.4%和10.7%。使用六通道施源器时,3D计划可显著降低直肠D0.1 cm3、D1.0 cm3、D2.0 cm3和Dmean约36.6%、24.8%、20.4%和6.1%,并降低了膀胱和尿道Dmean。与单通道施源器3D计划相比,六通道施源器3D计划进一步降低了直肠、膀胱和小肠的照射剂量。结论 使用单通道或六通道柱状施源器进行阴道内照射时,2D和3D治疗计划均取得了很好的靶区剂量分布。3D治疗计划与2D治疗计划相比,能降低以直肠为主的OAR受量,六通道施源器3D计划进一步降低了直肠照射剂量。  相似文献   

3.
目的 探讨3D打印技术在腔内近距离治疗个体化施源器制作中的运用。方法 对1例宫颈癌术后阴道残端狭窄并规则实体肿瘤患者,用显影剂浸泡过的纱条对患者阴道进行填塞后进行CT扫描,获取阴道腔内三维几何轮廓。利用软件进行轮廓提取,在靠近病灶侧预留三根腔道,使用3D打印机、医用硅胶材料进行施源器打印。将该施源器重新置入患者阴道内,CT扫描并纠正施源器位置。将最终CT图像输出至TPS进行靶区及OAR勾画,完成剂量分布计算。结果 3D打印个体化阴道施源器可以和靶体积形成良好的贴合,弯曲处管道的曲率>1 cm,可保证放射源的顺利通过;通过对插植软管进行剪切,将总的出源长度统一设定为1 280 mm,可实现个体化施源器与后装机的精确连接;病灶达到处方剂量的同时,膀胱、直肠剂量D2 cm3分别为320.4、331.5 cGy,不超过剂量限值。结论 利用3D打印技术制作个体化施源器适用于宫颈癌术后阴道残端狭窄并规则实体肿瘤的治疗,临床疗效与不良反应尚需进一步观察。  相似文献   

4.
目的 探讨3D打印模板辅助标准化施源器在宫颈癌影像引导自适应近距离治疗(BT)中的应用。方法 对 23例外照射(45Gy分25次)后宫旁受侵袭范围较大的 ⅢB期宫颈癌患者行MRI引导自适应BT,处方剂量为7 Gy/次,共4次。根据外照射前后MRI中肿瘤消退情况确定BT范围,预估应用标准化腔内联合组织间插植(IC+IS)施源器剂量欠量区域。对欠量区域虚拟经会阴组织间插植针道,并优化植入角度、间距、深度等。应用图形设计软件设计辅助插植模板,并使用3D打印技术打印辅助模板,并与标准化施源器结合紧密。在全麻条件下超声引导完成IC+IS,术后对患者行MRI定位扫描。将定位MRI传入治疗计划系统进行靶区和危及器官勾画,并给予IC+IS治疗计划设计优化,最终完成计划评估及治疗。结果 3D打印个体化插植模板平均打印时间为(3.5±1.0) h,辅助模板共引导植入插植针382根,单分次(4.2±1.5)根,剂量权重比为(16.49±9.50)%。靶区EQD2Gy,α/β=10剂量高危靶 区D90%为(90.45±3.03) Gy,中危靶 区D90%为(66.46±3.68) Gy。膀胱、直肠、小肠、乙状结肠的 D2cm3EQD2Gy,α/β=3分别为(82.69±2.60)、(73.20±2.52)、(69.35±3.32)、(69.39±3.27) Gy,均满足临床剂量要求。1年和 2年局部控制率、无远处转移生存率、总生存率分别为96%和87%、87%和70%、96%和78%。结论 利用3D打印技术制作的辅助插植施源器可以有效弥补现有标准化施源器在 ⅢB期宫颈癌临床BT时大体积靶区剂量的不足,为晚期宫颈癌BT提供了较为有效的方法。  相似文献   

5.
目的 探讨中晚期宫颈癌三维后装腔内放疗中三通道施源器的通道设计与OAR、靶区剂量间关系。方法 调取2015—2016年我院三维腔内治疗的15例中晚期宫颈癌数据,其中30次“阴道卵形两半球+宫腔管”的三通道施源器剂量参数纳入研究。在原靶区和OAR勾画、处方剂量不变基础上保留宫腔管单通道施源器,重新进行三维腔内照射设计的剂量参数作为对照组,配对t检验两组OAR剂量参数。结果 三通道、单通道施源器组直肠D2cc分别为(387.8±96.8)、(340.8±88.1) cGy;两组膀胱和乙状结肠D2cc分别为(443.2±87.5)、(719.4±243.0) cGy和(330.3±88.8)、(383.1±105.6) cGy。三通道组满足直肠(D2cc≤500 cGy)、膀胱(D2cc≤550 cGy)和乙状结肠(D2cc≤500 cGy)计划限量,单通道组膀胱和乙状结肠D2cc受量分别为大于和部分大于计划限量。单通道组膀胱和乙状结肠D2cc受量高于三通道组(P均<0.05)。结论 宫颈癌三维腔内放疗中“阴道卵形两半球+宫腔管”三通道施源器比宫腔管单通道可有效降低膀胱和乙状结肠受量,有利于计划优化和剂量实施。  相似文献   

6.
杨文翠  赵林  王小龙 《癌症进展》2022,20(8):854-858
目的 探讨采用3D打印技术制作的阴道多通道个体化模型塞插植治疗宫颈癌的近期疗效。方法 2013年11月至2015年8月收治的30例宫颈癌患者接受常规腔内治疗(ICBT),作为ICBT组,2015年9月至2016年10月收治的26例宫颈癌患者接受3D打印插植治疗(3DP-ISBT),作为3DP-ISBT组。比较两组患者的剂量学结果[高危临床靶体积(HR-CTV)D90和膀胱、直肠、乙状结肠D2cc],并评价近期疗效。结果 肿瘤直径5~6 cm、肿瘤直径≥7 cm、阴道侵犯﹥2/3及有宫旁侵犯的3DP-ISBT组宫颈癌患者HR-CTV D90均明显高于ICBT组患者,差异均有统计学意义(P﹤0.01)。3DP-ISBT组患者直肠、乙状结肠的D2cc均低于ICBT组,差异均有统计学意义(P﹤0.05)。3DP-ISBT组患者1年肿瘤局部控制率为86.2%,高于ICBT组的58.3%,差异有统计学意义(P﹤0.05)。治疗期间无严重不良反应。结论 与传统腔内治疗相比,3D打印多通道个体化阴道模型塞插植治疗宫...  相似文献   

7.
目的 对比研究环形施源器(Nucletron#090.617)和三管施源器(Nucletron#189.730)对宫颈癌患者三维近距离治疗受照剂量的影响。 方法 选取已完成治疗的根治性宫颈癌ⅡB—ⅣA期患者 40例,20例采用环形施源器,另外 20例采用三管施源器,分别统计三维近距离治疗计划中靶区 V150% 、D100和膀胱、直肠、小肠 D2 cc。采用立独样本t检验方法对比分析两种施源器在宫颈癌三维近距离治疗中CTV和OAR的剂量。 结果 环形施源器和三管施源器的靶体积分别为(66.04±13.86) cm3、(65.67±15.08) cm3(P=0.052)。环形施源器中 D100、V150%分别为(3.71±0.34) Gy、0.54±0.02;三管施源器中 D100、V150%分别为(3.37±0.49) Gy、0.56±0.04(P=0.016、0.034)。环形施源器中膀胱、直肠、小肠 D2 cc分别为(4.33±0.39)、(3.38±0.30)、(3.04±1.02) Gy,三管施源器的分别为(2.93±1.27)、(2.95±0.80)、(3.41±0.57) Gy (P=0.000、0.037、0.171)。 结论 宫颈癌三维近距离治疗中环形施源器靶区的覆盖度优于三管施源器,而膀胱、直肠受量同时也高于三管施源器,但小肠受量无差异。临床治疗中主要还是根据肿瘤的位置、侵犯范围以及阴道的条件来选择施源器。  相似文献   

8.
目的比较γ与剂量体积直方图(DVH)在宫颈癌容积调强弧形治疗(VMAT)剂量验证中的应用,并评估两者反映剂量偏差的能力。方法选取20例宫颈癌VMAT病例,由TrueBeam投照、使用FC65-G及ArcCheck测量并与Eclipse计算点、面剂量比对。由3DVH软件重建患者剂量,比较重建靶区D_(mean)、D_(95)%、D_(98)%、D_(2)%,左右股骨头V_(20Gy),直肠V_(40Gy),脊髓D1cm^(3)及50%处方剂量包绕区(IDV)D_(98)%、D_(2)%、D_(50)%与计划值差异并对各器官行三维γ分析。使用皮尔森相关系数分析点剂量偏差、二维γ通过率及其平均值、各器官三维γ通过率与剂量偏差相关性。结果电离室实测、3DVH重建与计划计算点剂量间偏差小,二维γ比对均通过(3%/3 mm,≥90%)。靶区平均剂量、IDV各参数偏差小于3%,直肠V_(40Gy)偏差差异最大。左右股骨头三维γ通过率最高,脊髓差异波动最大。实测、重建点剂量偏差大都与剂量偏差呈中等强度相关,二维γ通过率与各器官剂量偏差未发现明显相关,各病例靶区三维γ通过率与自身及IDV D_(50)%偏差间存在极强相关,其余相关性强弱无规律。结论基于γ和DVH评估均能一定程度揭示剂量误差,但均存在一定局限,临床中应将两者联合应用。  相似文献   

9.
目的:分析膀胱体积变化对宫颈癌近距离治疗中肿瘤和正常组织受量的影响。方法:2015年1月至2017年12月于本院首诊的66例拟行根治性放疗的宫颈癌患者,治疗方案采用外照射放疗同期化疗加近距离治疗。均采用同期顺铂40 mg/m2每周方案化疗,外照射均采用常规分割外照射放疗,1.8~2 Gy/次,1次/天,5次/周,盆腔预防放疗剂量45 Gy/25次,阳性区域转移淋巴结处方剂量55~57.5 Gy/25次。后装采用三维自适应近距离放疗,A点剂量6 Gy每次,共4次,采用宫腔管和双侧阴道穹窿管或环形施源器,在定位CT图像上勾画高危临床靶区(high risk clinical tumor volume,HRCTV)、膀胱、直肠、乙状结肠,制定后装治疗计划后行近距离放疗。结果:后装近距离治疗期间,随着膀胱体积增大,膀胱D1cc、D2cc接受的放疗剂量逐渐升高,有显著统计学差异(P<0.001),其中小于49.25 ml膀胱体积组膀胱受辐射量最小。而膀胱体积的变化不影响直肠D1cc和D2cc、乙状结肠D1cc和D2cc、HRCTV D90和HRCTV D95。随着后装次数的增加,膀胱体积有逐渐增加的趋势,虽然第一次后装时膀胱体积与第二、三次后装时膀胱体积无统计学差异,但是第一次后装时膀胱体积与第四次后装时膀胱体积有统计学差异(P=0.02)。结论:近距离治疗过程中控制膀胱体积可以减少膀胱受照射剂量,近距离治疗期间控制膀胱体积小于49.25 ml可能是一个更好地选择。  相似文献   

10.
目的:通过3D打印个体化模具辅助插植,降低宫颈癌近距离治疗难度.方法:前瞻性研究2019年6月至2020年7月30例于重庆大学附属肿瘤医院行根治性放化疗宫颈鳞状细胞癌患者,随机分为15例3D打印组(试验组)和15例通用施源器组(对照组).评估两组治疗情况、靶区适形指数(coformity index,CI)、高危临床靶...  相似文献   

11.
目的 研究后装腔内/组织间插植近距离治疗(IC/ISBT)与传统后装腔内近距离治疗(ICBT)相比较的剂量学差异及其近期疗效。方法 45例局部晚期宫颈癌患者采用IC/ISBT及ICBT方法进行后装近距离治疗,分别对两种治疗方法的A点(A1、A2)、D90%、D100%以及膀胱、结肠、直肠、小肠受量进行计算,同时观察近期疗效。结果 IC/ISBT比ICBT放疗A点剂量显著提升(P<0.05);并且IC/ISBT的D90%、D100%也均明显高于ICBT (P<0.05)。外照射后残存肿瘤直径≥3cm时,IC/ISBT比ICBT可获得较高的靶区剂量提升(P<0.05)。IC/ISBT与ICBT的膀胱、直肠、结肠、小肠D2cm3、D0.1cm3相近(P>0.05)。疗后1、3、6个月的近期疗效IC/ISBT与ICBT相近(P>0.05)。结论 局部晚期宫颈癌(残存肿瘤直径≥3cm)后装近距离治疗中IC/ISBT在不增加危及器官受量及降低近期疗效前提下显著地提高了靶区、A点剂量,具有明显剂量学优势。  相似文献   

12.
Objective To study the dosimetric differences and short-term efficacy between intracavitary/interstitial brachytherapy (IC/ISBT) and conventional intracavitary brachytherapy (ICBT). Methods Forty-five patients with locally advanced cervical cancer were treated with IC/ISBT and ICBT. Points A (A1,A2), D90%, D100%, organs at risk, and the doses of bladder, colon, rectum and small intestine were calculated and the short-term efficacy was observed between two groups. Results Point A dose was significantly improved in IC/ISBT compared with ICBT (P<0.05). The D90% and D100% in IC/ISBT were significantly higher than those in ICBT (both P<0.05). After brachytherapy, IC/ISBT could obtain a significantly larger increase in target dose when residual tumor diameter was ≥3 cm compared with ICBT (P<0.05). The D2cm3 and D0.1cm3 of bladder, rectum, colon and small intestine did not significantly differ between IC/ISBT and ICBT (all P>0.05). The 1-,3-and 6-month clinical efficacy did not significantly differ between two technologies (all P>0.05). Conclusion During brachytherapy for locally advanced cervical cancer (residual tumor diameter ≥3 cm), IC/ISBT significantly increases the doses of target area and point A without increasing the dose of organs at risk or lowering the short-term clinical efficacy, which has significant dosimetric advantages.  相似文献   

13.
Introduction: Endometrial cancer (EC) is a leading cause of female cancer in developed countries. The total abdominal hysterectomy and bilateral salpingo-oophorectomy with pelvic lymph node dissection is the primary management of endometrial cancer. Afterwards vaginal brachytherapy can be preferred either alone or combined with external beam radiotherapy to avoid the vault recurrence. This study was to assess the in-house multichannel applicator for HDR vaginal brachytherapy and dosimetric compression with the single channel applicator through DVHs. The main objective of this study was to design and development of an in-house multichannel applicator for HDR vaginal brachytherapy and dosimetric compression with the single channel applicator through DVHs. Materials and Methods: The multichannel applicator is a solid cylinder with 3 cm diameter, 13 cm length. It has a central channel surrounded by eight channels with a periphery arrangement in a single circle. We randomly selected eleven patients with endometrial carcinoma and 7Gy/per fraction of HDR dose was prescribed to CTV. Retrospectively, two 3D inverse treatment plans were created for each patient, with single channel loading and multichannel loading and the dose distribution of both plans could be compared. CTV coverage, rectum and bladder doses were compared. Results: The DVH analysis showed statistically significant difference between single and multichannel plan, that is for D95 of CTV (p=0.008), D100 of CTV (p=0.004) and 2cc of CTV (p=0.003). The p value for 1cc, 2cc and V70 are 0.003, 0.003 and 0.003 for rectum. On the other hand, bladder DVHs showed large difference between single and multichannel plan yet it is not statistically significant, and the p values for 1cc, 2cc and V 80 are 0.012, 0.009 and 0.225. Conclusion: The authors conclude that in house multichannel applicator with 3D inverse treatment planning techniques improves the dosimetric advantage over single channel applicators.  相似文献   

14.
PurposeAdjuvant high-dose-rate vaginal brachytherapy (VB) is commonly used in endometrial cancer. We evaluated the dosimetric and cost differences of using either a single plan or replan prior to each fraction for single- and multi-channel VB.Methods and MaterialsWe evaluated 84 fractions from 25 patients at our institution (16 single-channel patients each 3 fractions; 9 multi-channel patients each 4 fractions). All fractions were preceded by a computed tomographic (CT) simulation scan, after which a unique treatment plan was generated, dose points per International Commission on Radiation Units and Measurements (ICRU) 38. We calculated the dose to critical organs based on a decay-and-treat method utilizing the original catheter dwell-times for the initial fraction, and also the interfractional motion of the critical organ points between the initial and the subsequent CT scans.ResultsThe absolute mean dose difference was 14 cGy for bladder and 15 cGy for rectum between the replan and decay methods for single-channel, and 14 cGy for both organ points for the multi-channel cylinder. The bladder and rectum doses were not found to be significantly different between the replan and decay methods for either single-channel (bladder, P = .08; rectum, P = .19) or multi-channel cylinders (bladder, P = .85; rectum, P = .10). The mean interfractional displacement of the organ points between the initial and subsequent CT scans was 1.10 cm for the bladder and 0.67 cm for the rectum for single-channel, and 0.87 cm and 0.51 cm for multi-channel cylinders. The maximum interfractional motion was seen in the transverse plane for both organ points for both types of cylinders. At our institution, the decay method was 19% and 22% more cost-effective for single-channel and multi-channel cylinders, respectively.ConclusionsOur data show no dosimetric advantage, but higher costs, associated with replanning prior to each fraction for both single- and multi-channel VB. Fractional replanning should not be utilized on a routine basis.  相似文献   

15.
目的 研究三维后装中驻留点权重标准差与施源器位置不确定性对宫颈癌患者受量影响。方法 选取已完成治疗的根治性宫颈癌患者20例,均使用Fletcher施源器(Nucletron#189.730),基于原CT图像和结构信息,重新设定一组新计划,记录原计划和新计划中驻留点权重并计算驻留点权重标准差(DWSD),按照DWSD大小患者2个计划被分成高低两组,即LDWSD组(0.141~0.299)和HDWSD组(0.211~0.337),利用Oncentra® Brachy V4.3计划系统模拟Fletcher施源器中宫腔施源器,阴道施源器发生±1 mm位移时的剂量分布。统计CTV的D100、D90和V150,、膀胱、直肠、小肠的D0.1cc、D1cc和D2cc,分析DWSD与施源器位置不确定性对三维后装剂量的影响。结果DWSD越大,由施源器位置不确定性产生的剂量偏差就越大。当宫腔施源器、阴道施源器发生1 mm位移时,CTV的HDWSD组D100、D90、V150比LDWSD组分别高3.0%、23.8%、4.8%和0.5%、1.2%、5.2%,膀胱、直肠、小肠HDWSD组D0.1cc、D1cc、D2cc都高于LDWSD组,其中小肠最明显,分别高44.0%、22.8%、16.8%和10.3%、14.4%、12.4%。结论 宫颈癌三维后装计划的评估应考虑驻留点权重因素,可以减小由施源器位置不确定导致的剂量偏差。  相似文献   

16.
目的 CT引导下组织间插植近距离治疗宫颈复发癌患者的新方法,分析其剂量学优势。方法 16例接受过手术和术后辅助性体外放疗的宫颈复发癌患者接受了CT引导下金属针植入的组织间插植治疗。给予高危临床靶区(HR-CTV)6 Gy 6次剂量。评价本次近距离治疗肿瘤靶区HR-CTV D90;之前的体外照射和本次近距离治疗累加的膀胱、直肠及乙状结肠D2 cm3值。结果 HR-CTV D90的平均值为(52.5±3.3) Gy。膀胱、直肠、乙状结肠累加D2 cm3分别为(85.6±5.8)、(71.6±6.4)、(69.6±5.9) Gy。每次近距离治疗金属针的平均使用量为(6.1±1.5)。实际1年OS、LC分别为81%、69%。结论 CT引导下组织间插植近距离治疗对宫颈复发癌具有很好的DVH参数和较小的并发症,或许临床是可行的,但其远期临床结果尚待进一步观察。  相似文献   

17.
目的 探讨自主研发的单管式子宫颈癌后装施源器,相比于标准Fletcher三管施源器的 3年远期生存结果以及晚期损伤情况。方法 选取2011—2017年间西南医科大学附属医院就诊的子宫颈癌初诊患者,随机分为外照射+单管式后装组(专利单管组)和外照射+Fletcher三管式后装组。外照射采用6MV X线四野盒式或前后对穿野照射,30Gy后改野挡铅行后装治疗,1次/周,剂量为A点7Gy,共 5~6次(A点2Gy等效生物剂量 80~90Gy)。外照射时同步使用顺铂(40mg/m2)化疗,1次/周,治疗结束随访其疗效及不良反应并对比。结果 符合入组条件并完成治疗,Fletcher三管组 150例,专利单管组 149例。截至 2020年12月全部患者随访时间满 3年,中位随访时间61个月。Fletcher三管组的 3年总生存率、无进展生存率和局部无失败生存率分别为76.3%、78.1%和75.4%,而专利单管组分别为83.8%、80.3%和85.5%。3-4级晚期放射性直肠炎三管组3.3%,单管组6.7%(P=0.122)。3-4级晚期放射性膀胱炎三管组1.3%,单管组0.7%(P=1.000)。结论 专利单管式子宫颈癌后装施源器与标准Fletcher三管施源器 3年生存数据疗效相当且晚期不良反应相似。  相似文献   

18.
目的 探讨自制插植针植入棒施源器在妇科肿瘤术后阴道残端近距离腔内放疗的可行性和安全性,评估其临床应用价值。方法 收集中山大学肿瘤防治中心收治的妇科肿瘤术后患者62例,所有患者均有术后放疗指征,需接受三维近距离后装放疗补量。根据患者阴道残端情况选用不同型号插植针植入棒模板,依照预设通道在模板内放置阴道管和插植针。按照统一标准勾画靶区及危及器官,制定放疗计划,高危临床靶区(HR-CTV)处方剂量为5.5 Gy/次,通过剂量体积参数图评估靶区和危及器官体积、受照剂量等参数。结果 62例患者均在插植针植入棒模板引导下顺利完成后装放疗,共行140次插植治疗,剂量参数HR-CTV包绕90%靶区体积的平均剂量D90%为(575.48±22.30)cGy,包绕膀胱、直肠、乙状结肠2 cm³体积的平均剂量D2cm³分别为(328.69±102.71)cGy、(369.14±46.59)cGy、(27.28±71.27)cGy,小肠未进入靶区照射范围无统计,靶区体积大小、危及器官剂量之间的差异具有统计学意义(P<0.05)。结论 插植针植入棒施源器在妇瘤术后残端近距离腔内放疗有明显临床优势,满足预计划剂量要求,操作简易,具有良好应用前景。  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号