首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 15 毫秒
1.
2.
OBJECTIVE: To describe the relative contribution of and risk factors for both community-acquired and nosocomial methicillin-resistant Staphylococcus aureus (MRSA) infections. DESIGN: Retrospective cohort study. SETTING: 270-bed, tertiary-care children's hospital. PARTICIPANTS: All MRSA-infected children from whom MRSA was recovered between October 1, 1999, and September 30, 2001. METHODS: Demographic, clinical, and risk factor data were abstracted from medical records. Categorical variables were analyzed using the chi-square or Fisher's exact test and continuous variables were analyzed using the Mann-Whitney test. RESULTS: Of the 62 patients with new MRSA infection, 37 had community-acquired MRSA and 25 had nosocomial MRSA. Most community-acquired MRSA infections were of the skin and soft tissue, the middle ear, and the lower respiratory tract. Nosocomial MRSA infections occurred in the lower respiratory tract, the skin and soft tissue, and the blood. Risk factors for infection, including underlying medical illness, prior hospitalization, and prior surgery, were similar for patients with community-acquired MRSA and nosocomial MRSA. History of central venous catheterization and previous endotracheal intubation was more common in patients with nosocomial MRSA. Only 3 patients with community-acquired MRSA had no identifiable risk factor other than recent antibiotic use. Resistance for clindamycin, erythromycin, and levofloxacin was similar between strains of community-acquired MRSA and nosocomial MRSA. CONCLUSIONS: Similarities in patient risk factors and resistance patterns of isolates of both community-acquired and nosocomial MRSA suggest healthcare acquisition of most MRSA. Thus, classifying MRSA as either community acquired or nosocomial underestimates the amount of healthcare-associated MRSA.  相似文献   

3.
4.
The objective of this study was to investigate the state of mupirocin resistance in methicillin-resistant Staphylococcus aureus (MRSA) in a community hospital in Japan. Ninety strains of MRSA were isolated from the respiratory tract of 56 patients (group I, Jun 1990-Aug 1996) before introduction of mupirocin in Japan, which were compared with 168 strains from 48 patients (group II, Sept 1996-Jan 1998) and 146 strains from 85 patients (group III, Feb 1999-Dec 1999) isolated after introduction of mupirocin. Comparisons were made by determining the minimum inhibitory concentrations (MIC) against nine antibiotics. Fifty-five MRSA isolates from 27 patients [13 (27.1%) of 48 in group II and 14 (16.5%) of 85 in group III] after introduction of mupirocin showed low-level resistance to mupirocin (MIC, 6.25 to 50 microg/ml) but the remaining isolates were sensitive to mupirocin (MIC < or =3.13 microg/ml). Most patients colonized with low-level mupirocin-resistant MRSA were elderly (> or =65 years of age), on total parenteral nutrition or nasal feeding and had other underlying diseases. The proportion of patients colonized with low-level mupirocin-resistant MRSA following repeated use of mupirocin was higher in patients of group II than those of group III. Molecular typing by pulsed-field gel electrophoresis (PFGE) demonstrated that the pattern of 13 MRSA isolates from 13 patients of group II consisted of three patterns (A, B, C) with predominance of pattern A, while the pattern of 13 MRSA isolates from 13 patients of group III consisted of three patterns (A, C, D) with predominance of patterns A and D. Our results indicated that resistance of MRSA to mupirocin remains at a low level at present in Japan. However, we should be aware of the possible emergence of MRSA highly resistant to mupirocin in the future.  相似文献   

5.
Transmissible mupirocin resistance in Staphylococcus aureus   总被引:5,自引:0,他引:5  
The spread of two strains of Staphylococcus aureus with high level resistance to mupirocin is described. The resistance proved to be easily transferred to other S. aureus strains by filter mating experiments and on the skin of mice. No plasmid band corresponding to the resistance could be demonstrated by agarose gel electrophoresis or by caesium chloride gradient centrifugation but cleavage of 'chromosomal' DNA from resistant recipients showed bright bands of DNA absent from sensitive controls.  相似文献   

6.
Molecular epidemiology of methicillin-resistant Staphylococcus aureus   总被引:4,自引:0,他引:4  
Subtyping methicillin- resistant Staphylococcus aureus (MRSA) isolates and tracking nosocomial infections have evolved from phenotypic to genotypic approaches; most laboratories now depend on pulsed-field gel electrophoresis (PFGE). We discuss the limitations of current image-based genotyping methods, including PFGE, and the advantages (including ease of entering data into a database) of using DNA sequence analysis to control MRSA infections in health-care facilities.  相似文献   

7.
High-level resistance to mupirocin in meticillin-resistant Staphylococcus aureus (MRSA) jeopardizes its role in nasal decolonization protocols. We carried out a study in 2010 to determine the prevalence of high-level mupirocin resistance in our tertiary-care hospital. The prevalence of high-level resistance to mupirocin in MRSA in this hospital was 11%. There was also complete agreement between the genotypic and phenotypic methods of detection of high-level mupirocin resistance in 24 of the screening isolates.  相似文献   

8.
OBJECTIVE: To determine the impact of the screening test, nursing workload, handwashing rates, and dependence of handwashing on risk level of patient visit on methicillin-resistant Staphylococcus aureus (MRSA) transmission among hospitalized patients. SETTING: General medical ward. METHODS: Monte Carlo simulation was used to model MRSA transmission (median rate per 1,000 patient-days). Visits by healthcare workers (HCWs) to patients were simulated, and MRSA was assumed to be transmitted among patients via HCWs. RESULTS: The transmission rate was reduced from 0.89 to 0.56 by the combination of increasing the sensitivity of the screening test from 80% to 99% and being able to report results in 1 day instead of 4 days. Reducing the patient-to-nurse ratio from 4.3 in the day and 6.8 at night to 3.8 and 5.7, respectively, reduced the number of nosocomial infections from 0.89 to 0.85; reducing the ratio to 1 and 1, respectively, further reduced the number of nosocomial infections to 0.32. Increases in handwashing rates by 0%, 10%, and 20% for high-risk visits yielded reductions in nosocomial infections similar to those yielded by increases in handwashing rates for all visits (0.89, 0.36, and 0.24, respectively). Screening all patients for MRSA at admission reduced the transmission rate to 0.81 per 1,000 patient-days from 1.37 if no patients were screened. CONCLUSION: Within the ranges of parameters studied, the most effective strategies for reducing the rate of MRSA transmission were increasing the handwashing rates for visits involving contact with skin or bodily fluid and screening patients for MRSA at admission.  相似文献   

9.
目的 了解金黄色葡萄球菌(SAU)对莫匹罗星高水平耐药(MUH)的状况,并探讨其耐药菌株对临床常用抗菌药物的耐药特性.方法 用美国BD公司Phoenix-100型全自动细菌鉴定药敏系统鉴定细菌及做药敏试验,该仪器可以同时检测耐甲氧西林金黄色葡萄球菌(M RSA)和莫匹罗星高水平耐药的金黄色葡萄球菌.结果 共检出金黄色葡萄球菌382株,其中MUH菌株检出25株,检出率为6.5%,其中23株为MRSA,占92.0%;莫匹罗星高水平耐药的金黄色葡萄球菌对阿米卡星等15种临床常用抗菌药物耐药率较高,均>80%,且呈多药耐药,但对万古霉素、利奈唑胺全部敏感,呋喃妥因耐药率也较低.结论 临床分离的金黄色葡萄球菌中,已出现莫匹罗星高水平耐药的菌株,临床应加强对该类菌株的监测,以减少耐药菌株的产生和流行.  相似文献   

10.
OBJECTIVES: To review cases of community-onset Staphylococcus aureus bacteremia and to evaluate whether the risk factors and epidemiology of methicillin-resistant S. aureus (MRSA) bacteremia have changed from early reports. DESIGN: Retrospective case-comparison study of community-onset MRSA (n = 26) and methicillin-susceptible S. aureus (MSSA) (n = 26) bacteremias at our institution. SETTING: A 600-bed urban academic medical center. PATIENTS: Twenty-six patients with community-onset MRSA bacteremia were compared with 26 patients with community-onset MSSA bacteremia. Molecular analysis was performed on S. aureus isolates from the 26 MRSA cases as well as from 13 cases of community-onset S. aureus bacteremia from 1980 and 9 cases of nosocomial S. aureus bacteremia from 2001. RESULTS: The two groups were similar except that patients with MRSA bacteremia were more likely to have presented from a long-term-care facility (26.9% vs 4%; P = .05) and to have had multiple admissions within the preceding year (46% vs 15%; P = .03). Clamped homogeneous electric fields analysis of MRSA isolates from 1982 revealed predominantly that one clone was the epidemic strain, whereas there were 14 unique strains among current community-onset isolates. Among current nosocomial isolates, 3 patterns were identified, all of which were present in the community-onset cases. CONCLUSIONS: Previously described risk factors for MRSA acquisition may not be helpful in predicting disease due to the polyclonal spread of MRSA in the community. Unlike early outbreaks of MRSA in patients presenting from the community, current acquisition appears to be polyclonal and is usually related to contact with the healthcare system.  相似文献   

11.
This study sought to determine the rate of nasal methicillin-resistant Staphylococcus aureus (MRSA) carriage among hospital staff and outpatients. Nasal swabs were obtained from 500 outpatients and 500 hospital staff. Hospital staff were 2.3-fold more likely to carry MRSA than were outpatients (6% vs 2.6%, P = .013).  相似文献   

12.
In the early 1990s, severe enteritis caused by methicillin-resistant Staphylococcus aureus (MRSA enteritis) was prevalent in Japan, but the incidence has since decreased. We compared the genotypes and phenotypes of 12 isolates that caused MRSA enteritis (enteritis isolates), detected between 1990 and 1993, with 186 non-enteritis isolates detected between 1998 and 2002. Organisms were investigated using pulsed-field gel electrophoresis (PFGE), coagulase typing and reverse passive latex agglutination to detect production of staphylococcal enterotoxins (SE) and toxic shock syndrome toxin-1 (TSST-1); and polymerase chain reaction (PCR) for detection of the structural genes entA, entB, entC, entD and tst, which encode proteins SE-A, SE-B, SE-C, SE-D and TSST-1, respectively. The 12 enteritis isolates were classified into four types and four subtypes. Only seven of the 186 non-enteritis isolates had PFGE patterns indistinguishable from the enteritis isolates. Eight of the 12 enteritis isolates had entA, entC and tst, and produced high levels of SE-A and TSST-1, but not SE-C. Of the 186 non-enteritis isolates, 157 produced SE-C and TSST-1, but not SE-A. The seven non-enteritis isolates with a PFGE pattern indistinguishable from the enteritis isolates did not produce SE-A, and showed relatively low levels of TSST-1 production. These isolates may have continued to inhabit our ward since the earlier outbreak, but acquired a different phenotype. In conclusion, the disappearance of MRSA enteritis may have resulted from the decreased incidence of enteritis-causing clones and phenotypical changes.  相似文献   

13.
OBJECTIVES: To describe the epidemiology of methicillin-resistant Staphylococcus aureus (MRSA) at a university hospital in Tenerife, Canary Islands, during a 40-month period and to evaluate the effectiveness of the application of control measures. DESIGN: Laboratory-based surveillance, medical charts and microbiological records review, and characterization of strains by pulsed-field gel electrophoresis (PFGE) were used to describe the epidemiology. Infection control practices were introduced as an intervention. SETTING: A 650-bed, tertiary-care university hospital. SUBJECTS: Patients with clinical and nasal isolates of MRSA and colonized staff members. RESULTS: The rate of nosocomial MRSA infections was 32.5% for 1997, 17.9% for 1998, 14.5% for 1999, and 25.6% during the first 4 months of 2000. The major sites of isolation for nosocomial MRSA infection included surgical wounds (25%) and the lower respiratory tract (24%). Intensive care units and surgical specialties had more frequent MRSA cases. Characteristics associated with nosocomial MRSA isolates included prior use of intensive antibiotic therapy, prolonged hospital stays, major underlying illness, invasive procedures, and older age. PFGE type A (subtype A1) was the strain most frequently found and the only PFGE type involved in clusters. CONCLUSIONS: Surveillance cultures and contact droplet precautions were followed by decreased rates for 2 years. Nevertheless, the spread of PFGE subtype A1 to many different areas of the hospital and the increase in incidence during the first third of 2000 indicates either that surveillance cultures were not used widely enough or that compliance with isolation measures was suboptimal.  相似文献   

14.
目的 了解耐甲氧西林金黄色葡萄球菌临床感染现状及其耐药性,为临床合理使用抗菌药物提供科学依据.方法 采用phonix-100对314株金黄色葡萄球菌进行鉴定和药敏试验,数据统计使用WHONET5.5软件及SPSS17.0软件进行.结果 共分离出314株金黄色葡萄球菌,其中耐甲氧西林金黄色葡萄球菌(MRSA) 164株,占52.2%,甲氧西林敏感金黄色葡萄球菌(MSSA) 150株,占47.8%;标本来源以痰液为主,占58.3%,其次是伤口分泌物占29.3%;MRSA和MSSA对万古霉素、替考拉宁、利奈唑胺无耐药,MRSA对阿米卡星、庆大霉素、妥布霉素、利福平、环丙沙星、磺胺甲噁唑/甲氧苄啶、克林霉素、红霉素、四环素耐药率分别为86.6%、89.6%、93.3%、43.3%、87.8%、6.7%、84.1%、84.1%、85.3%;MSSA对青霉素、阿米卡星、庆大霉素、妥布霉素、利福平、环丙沙星、磺胺甲噁唑/甲氧苄啶、克林霉素、红霉素、四环素耐药率分别为92.0%、0.7%、32.7%、32.7%、2.7%、10.0%、34.7%、36.0%、59.3%、22.0%;MRSA对大环内酯类、氨基糖苷类、氟喹诺酮类、四环素类、克林霉素耐药率明显高于MSSA.结论 MRSA分离率较高,耐药性严重,应引起重视,临床应根据药敏试验结果合理选择抗菌药物.  相似文献   

15.
Data on methicillin-resistant Staphylococcus aureus (MRSA) cases notified to the National Infectious Disease Register (NIDR) and antibiotic resistance profiles of MRSA isolates sent to the national reference laboratory between 1997 and 2002 were analysed. In addition, the diagnostic methods used for MRSA identification in Finnish microbiology laboratories, the number of MRSA screening specimens studied, and the MRSA situation in long-term care facilities in 2001 were reviewed. MRSA cases notified to the NIDR rose from 120 in 1997 to 597 in 2002 (from 2.3 to 11.5 cases per 100,000 population). The increase was greatest in elderly people and outside Helsinki metropolitan area, in the districts where the proportion of non-multiresistant strains was most prominent. The National Committee for Clinical Laboratory Standard's guidelines for the oxacillin disk diffusion test were followed, except for the incubation temperature and time, which may have hindered detection of some MRSA strains. There was a wide geographic variation in the rates of MRSA, but this was not related to screening activity. MRSA isolates from long-term facilities accounted for more than half of the notifications to the NIDR in 2001.  相似文献   

16.
A maternity hospital outbreak of methicillin-resistant Staphylococcus aureus with a strain other than EMRSA-1 is described. In contrast to previously documented outbreaks, which have usually centered on special care baby units, this outbreak mainly involved the routine ante-natal and postnatal wards. Thirty-seven mothers, 18 babies and nine staff were affected over a 6-week period. The high turnover of very mobile maternity patients and the open-plan design of the hospital influenced the course of the outbreak and adversely affected implementation of infection control measures. Significant environmental contamination and a very high rate of maternal perineal MRSA colonization were notable epidemiological features.  相似文献   

17.
A biphasic outbreak of methicillin-resistant Staphylococcus aureus in intensive-care units of a German tertiary-care hospital afflicted 89 patients within 4 years. The spread of the outbreak most likely was facilitated by the contamination of mobile radiograph equipment. The outbreak was controlled by measures of hospital hygiene.  相似文献   

18.
OBJECTIVE: To determine the efficacy of mupirocin ointment in reducing nasal colonization with mupirocin-susceptible, methicillin-resistant Staphylococcus aureus (MS MRSA) as well as mupirocin-resistant MRSA (MR MRSA). DESIGN: Prospective evaluation in which patients colonized with MRSA were treated twice daily with 2% topical mupirocin ointment for 5 days. SETTING: James H. Quillen Veterans' Affairs Medical Center. PATIENTS: Forty hospitalized patients with two anterior nares cultures positive for MRSA within a 7-day period. METHODS: Treated patients had post-treatment cultures at day 3 and weeks 1, 2, and 4. Isolates underwent mupirocin-susceptibility testing and DNA typing. MRSA clearance and type turnover were assessed for isolates that were mupirocin-susceptible, low-level (LL) MR MRSA and high-level (HL) MR MRSA. RESULTS: Post-treatment nares cultures on day 3 were negative for 78.5%, 80%, and 27.7% of patients with MS MRSA, LL-MR MRSA, and HLMR MRSA, respectively. Sustained culture negativity at 1 to 4 weeks was more common in the MS MRSA group (91%) than in the LL-MR MRSA group (25%) or the HL-MR MRSA group (25%). Positive post-treatment cultures usually showed the same DNA pattern relative to baseline. Plasmid curing of 18 HL-MR MRSA resulted in 15 MS MRSA and 3 LL-MR MRSA. CONCLUSIONS: Mupirocin was effective in eradicating MS MRSA, but strains of MR MRSA often persisted after treatment. This appeared to reflect treatment failure rather than exogenous recolonization. MR MRSA is now more prevalent and it is appropriate to sample MRSA populations for mupirocin susceptibility prior to incorporating mupirocin into infection control programs.  相似文献   

19.
20.
OBJECTIVES: To determine whether patients who were colonized or infected with methicillin-resistant Staphylococcus aureus (MRSA) persistently carried the same strain and to identify the extent of strain variation within a population of patients. DESIGN: Molecular typing by pulsed-field gel electrophoresis (PFGE) of stored MRSA isolates. SETTING: A Veterans Administration Medical Center with 288 hospital, 45 intermediate-care, and 75 extended-care beds. ISOILATES: Between January 1991 and March 1993, 91 patients had MRSA identified in routine cultures. One hundred isolates from 57 patients (63%) were available for typing. RESULTS: Before 1988, only occasional MRSA isolates were identified. By 1993, 50% of S. aureus isolates from unique patients were resistant to methicillin. PFGE identified 7 MRSA strains, 3 of which were identified in specimens from 1 patient each. The most common strains were SD4 (20 patients), SD1 (12 patients), SD2 (12 patients), and SD5a (5 patients). Twenty patients had 2 or more isolates obtained at least 1 week apart (mean, 30.7 weeks; range, 1 to 102 weeks). Of these patients, 12 were colonized or infected with only one strain (mean time observed, 25.1 weeks; range, 1 to 82 weeks). Eight patients had at least 2 different strains (mean time observed, 39 weeks; range, 2 to 102 weeks). CONCLUSION: Numerous MRSA strains circulated in this endemic setting, 40% of patients observed over time were colonized or infected with more than one strain. Molecular typing was an essential tool for evaluating the epidemiology of MRSA in this setting.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号