首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 734 毫秒
1.

Purpose

To assess the clinical value of quantitative elastosonography compared with multiparametric ultrasound in differentiating the nature of thyroid nodules.

Methods and materials

Ninety-seven consecutive patients (32 males, 65 females, mean age, 54 years, range 20–81 years) with thyroid nodules previously detected at color-Doppler ultrasound (CDUS), were prospectively examined with elastosonography with dedicated quantitative software (Elasto-Q, Toshiba) before surgery. Ultrasound examination and elastosonography were evaluated by two investigators in consensus. US features, color-Doppler pattern, and strain ratio value were evaluated. Sensitivity and specificity of CDUS and sono-elastography were compared using X2 test and ROC curves.

Results

Sensitivity and specificity of hypoechogenicity, irregular margins or suspicious halo features, CDUS blood flow pattern, and strain ratio in the diagnosis of malignant nodules were 56.8%, 62.2%, 54.1% and 97.3% and 71.7%, 93.3%, 28.3%, and 91.7%, respectively. Elastosonography was more sensitive and specific than all ultrasonographic features in predicting malignancy of the thyroid nodules (p < 0.0001). According to elastosonographic features the lesions characterized by strain ratio ≥2 were highly likely to be of malignant nature (p < 0.0001, O.R. 396, 95%, CI: 44–3530).

Conclusions

The results of the present study suggest that elastosonography with Q system is a valuable tool in the characterization of thyroid nodules and it seems to be far more accurate than CDUS. These findings as well as those of previous studies support its use in selecting patients who are candidates for surgery.  相似文献   

2.

Objectives

To describe perfusion CT features of locally advanced pancreatic ductal adenocarcinoma and to evaluate correlation with tumor grading.

Methods

Thirty-two patients with locally advanced pancreatic adenocarcinoma were included in this study. Lesions were evaluated by P-CT and biopsy after patient's informed consent. P-CT parameters have been assessed on a large single and on 6 small intratumoral ROIs. Values obtained have been compared and related to the tumor grading using Mann–Whitney U test. Sensibility, specificity, positive predictive value (PPV), negative predictive value (NPV) and accuracy in predicting tumor grading have been calculated for cut-off values chosen by using ROC curves.

Results

Out of 32 lesions, 12 were classified as low grade and 20 as high grade. A statistically significant difference between high and low grade neoplasms were demonstrated for PEI and BV parameters. PEI and BV cut-off values were respectively 17.8 HU and 14.8 ml/100 g. PEI identified high grade neoplasms with a 65% sensitivity, 92% specificity, 93% PPV, 61% NPV and 75% accuracy. BV identified high grade neoplasms with a 80% sensitivity, 75% specificity, 84% PPV, 69% NPV, 78% accuracy. Considering both PEI and BV, P-CT identified high grade lesions with a 60% sensitivity, 100% specificity, 100% PPV, 60% NPV and 75% accuracy.

Conclusions

PEI and BV perfusion CT parameters proved their efficiency in identifying high grade pancreatic adenocarcinoma.  相似文献   

3.

Purpose

The aim of this study was to determine the accuracy of elastosonography in the differential diagnosis of thyroid nodules using a qualitative [evaluation of the stiffness score (SS)] and quantitative assessment [evaluation of the strain ratio (SR)].

Materials and methods

In our single-centre retrospective study, 368 patients were enroled between December 2010 and March 2012 (134 men, 234 women, mean age 56.1 ± 14.2) with a diagnosis of thyroid nodules, who underwent conventional ultrasonographic and elastosonographic evaluation. The SS and SR were assessed and the results were expressed in terms of sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV). The nodules were subjected to needle aspiration.

Results

Forty-four nodules were malignant (TIR ≥ 3) and 324 benign on cytological analysis. Considering a cut-off of SS > 2, we had 91 % sensitivity, 68 % specificity, 27 % PPV and 98 % NPV. Considering a cut-off of SR ≥ 3.28, we had 81.8 % sensitivity, 82.7 % specificity, 39.1 % PPV and 97.1 % NPV.

Conclusions

The SR calculation did not provide additional data to the SS, which remains the elastosonography benchmark. It will be necessary to validate these preliminary data by larger prospective randomised trials.  相似文献   

4.

Purpose

This study was done to compare quantitative elastosonography and ultrasound analysis in the characterisation of thyroid nodules.

Materials and methods

From July 2009 to September 2011, 123 patients with 147 thyroid nodules were included in our study. All patients enrolled had to undergo thyroidectomy because of nodular thyroid disease (goitre or nodules). After preliminary examination with conventional ultrasound (US) and colour Doppler US, the patients were examined with elastosonography, using high-level equipment (Toshiba Aplio XG) and quantitative software (Elasto-Q). Each lesion was characterised using an US score (echogenicity, borders, microcalcifications and colour Doppler pattern), and then by elastosonographic strain ratio. Each patient subsequently underwent thyroidectomy. Histological results were used as the gold standard.

Results

Histological examination demonstrated 89 benign and 58 malignant lesions. On average, the strain ratio value was 2.84±2.69 (range, 0.05–14.5; p=0.001). Sensitivity and specificity of the US score were about 56% and 72%, respectively, whereas those of the strain ratio were 93% and 89%, using a cut-off of 2 obtained with receiver operating characteristic (ROC) curve analysis. Elastosonography was more accurate than US and colour Doppler US in characterising thyroid nodules (p=0.002).

Conclusions

Quantitative elastosonography is a useful diagnostic tool in the evaluation of thyroid lesions, and can be used to limit fine-needle aspiration cytology and improve the selection of patients for thyroidectomy.  相似文献   

5.

Purpose

To assess the role of 64-row multidetector computed tomography virtual hysterosalpingography (MDCT VHSG) in the evaluation of the female reproductive tract in infertile patients and compare it with conventional X-ray hysterosalpingography (HSG).

Methods and material

The studied group included 25 patients with infertility. All patients were evaluated with 64-row MDCT VHSG and X-ray HSG. Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of both examinations for uterine pathology, fallopian tube pathology and per lesion pathology were calculated. The duration for both examinations, patient discomfort and patient effective dose were documented.

Results

The mean duration for MDCT VHSG and X-ray HSG was 6.5 ± 1.9 and 26.9 ± 2.9 min respectively, MDCT VHSG has a significantly less median patient discomfort and mean patient effective dose. Sensitivity, specificity, PPV and NPV for uterine pathology were 100%, 100%, 100% and 100% respectively for MDCT VHSG and 90%, 93.3%, 90% and 93.3% respectively for X-ray HSG, the inter-method agreement for uterine pathology was k = 0.83. Sensitivity, specificity, PPV and NPV for the detection of fallopian tube pathology were 100%, 93%, 91 and 100% respectively for MDCT VHSG and 100%, 86%, 85% and 100% respectively for X-ray HSG and k = 0.76. Sensitivity, specificity, PPV and NPV for per patient pathology were 100%, 91%, 93% and 100% respectively for MDCT VHSG and 87%, 80%, 87% and 80% respectively for X-ray HSG and k = 0.75.

Conclusion

MDCT VHSG could be an excellent new alternative diagnostic procedure in the infertility assessment workup.  相似文献   

6.

Purpose

To prospectively evaluate the feasibility of using the “iliac wing sign (IWS)” as an indicator of bone and/or soft-tissue injury of the pelvis and hips on magnetic resonance (MR) imaging. IWS means edema of the iliacus muscle attachment entering the iliac wing that is visualized as a linear high signal intensity on fat-suppressed T2-weighted MR images.

Methods

Consecutive 106 patients who complained of hip pain were enrolled in this study. We evaluated the correlation between IWS and bone and/or soft-tissue injury of the pelvis and hips using Fisher's exact test. Further, performance parameters of sensitivity, specificity, accuracy, the positive predictive value (PPV), and negative predictive value (NPV) of IWS were calculated.

Results

Thirty-eight of the 106 (36%) patients had bone and/or soft-tissue injury. Twenty-seven of these 38 (71%) patients with injury showed a positive IWS, while only 11 of 68 (16%) patients without injury showed a positive IWS (p < .0001). IWS, thus, yielded a sensitivity of 71%, specificity of 84%, accuracy of 79%, positive predictive value (PPV) of 71%, and negative predictive value (NPV) of 84%.

Conclusion

In cases with a positive IWS, the careful interpretation of MR images is needed because injury presence is highly likely, as suggested by the relatively high sensitivity and PPV. IWS absence may mean a low probability of injury because of the high specificity and NPV.  相似文献   

7.

Objectives

To study the diagnostic performance of computed tomography (CT) quantification of minimal lumen area (MLA) based on multiple factors (image quality, calcification and lesion locations), with reference to intravascular ultrasound (IVUS).

Methods

Consecutive clinically ordered patients were prospectively enrolled in our study. CT quantification of MLA was manually measured on cross-sectional view and further compared with IVUS findings. A significant lesion was defined as ≤6 mm2 MLA for the left main (LM) coronary artery and a ≤4 mm2 MLA for other epicardial vessels.

Results

Non-calcified lesions had good correlation between CT and IVUS (r = 0.96) and the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were 85% (51/60), 93.94% (31/33), 96.23% (51/53) and 77.5% (31/40) respectively. Decreased correlation (r = 0.814) lower specificity (23.81% (5/21)) and positive predictive value (60.98% (25/41)) were observed in calcified subgroup. Artifact-absent lesions demonstrated excellent correlation (r = 0.967) and the sensitivity, specificity, PPV and NPV were 96% (48/50), 93.94% (31/33), 96% (48/50) and 93.94% (31/33) respectively. Impaired correlation (r = 0.584) was noted in artifact-present lesions and the sensitivity, specificity, PPV and NPV were 80% (28/35), 23.81% (5/21), 63.64% (28/44) and 41.67% (5/12) respectively. Excellent correlation between CT and IVUS was noted in proximal epicardial vessels (r = 0.908) and the sensitivity, specificity, PPV and NPV were 92.31% (36/39), 78.13% (25/32), 83.72% (36/43) and 89.29% (25/28) respectively. Middle right coronary artery lesions showed non-significant correlation (r = 0.54, p = 0.055).

Conclusions

CT quantification of MLA can only be accurately achieved in non-calcified lesions with absence of artifact. Diagnostic performance is impaired in calcified lesions.  相似文献   

8.

Purpose

To assess the findings of recurrent Crohn's disease in the neoterminal ileum on small bowel follow through (SBFT) and computed tomography (CT) as well as the overall diagnostic performance of these imaging tests.

Methods

Our radiology database yielded 52 patients with an ileocolic anastomosis for Crohn's disease who underwent SBFT and CT. The images were reviewed to determine the sensitivity, specificity, PPV, and NPV for individual findings of recurrent Crohn's disease in the neoterminal ileum. The overall sensitivity, specificity, PPV, and NPV of these tests for recurrent Crohn's disease were determined by comparing imaging reports to endoscopic and surgical findings in 45 patients (87%) and clinical response to treatment in seven (13%).

Results

SBFT had a sensitivity of 90%, specificity of 85%, PPV of 95%, and NPV of 73% for detecting recurrent Crohn's disease, and CT had a sensitivity of 77%, specificity of 69%, PPV of 88%, and NPV of 50%. These tests combined had a sensitivity of 95%, specificity of 69%, PPV of 90%, and NPV of 82%. The most common findings were luminal narrowing, thickened folds, and ulcers (especially aphthoid lesions) on SBFT and bowel wall thickening on CT. CT also revealed extraenteric collections not visualized on SBFT in three patients (8%).

Conclusions

Our experience suggests that SBFT is more sensitive and specific than CT for detecting recurrent Crohn's disease in the neoterminal ileum, mainly because of the ability of barium studies to depict aphthoid lesions not visualized on CT. Conversely, CT is better for detecting extraenteric findings such as abscesses. When combined, these tests have a higher sensitivity for detecting recurrent Crohn's disease than either test alone.  相似文献   

9.

Objective

To assess the reliability of radiologic identification using visual comparison of ante and post mortem paranasal sinus computed tomography (CT).

Subjects and methods

The study was approved by the responsible justice department and university ethics committee. Four blinded readers with varying radiological experience separately compared 100 post mortem to 25 ante mortem head CTs with the goal to identify as many matching pairs as possible (out of 23 possible matches). Sensitivity, specificity, positive and negative predictive values were calculated for all readers. The chi-square test was applied to establish if there was significant difference in sensitivity between radiologists and non-radiologists.

Results

For all readers, sensitivity was 83.7%, specificity was 100.0%, negative predictive value (NPV) was 95.4%, positive predictive value (PPV) was 100.0%, and accuracy was 96.3%. For radiologists, sensitivity was 97.8%, NPV was 99.4%, and accuracy was 99.5%. For non-radiologists, average sensitivity was 69.6%, negative predictive value (NPV) was 91.7%, and accuracy was 93.0%. Radiologists achieved a significantly higher sensitivity (p < 0.01) than non-radiologists.

Conclusions

Visual comparison of ante mortem and post mortem CT of the head is a robust and reliable method for identifying unknown decedents, particularly in regard to positive matches. The sensitivity and NPV of the method depend on the reader's experience.  相似文献   

10.

Purpose

CT perfusion has been proposed for pancreatic lesion characterization. However, scan and analysis protocols influence numerical data. To overcome this, the purpose of our study is to evaluate the use of time–density curves obtained from MDCT perfusion of the pancreas for the characterization of normal parenchyma, adenocarcinoma, chronic pancreatitis and endocrine tumors.

Methods

31 patients with solid pancreatic lesions and 21 patients with renal cell carcinoma underwent 64-row MDCT perfusion of the pancreas after injection of 50 cc of a 370 mg I/ml solution at 5 cc/s. 63 time–density curves were obtained from normal parenchyma (21 patients), adenocarcinoma (25), endocrine tumors (4) and atrophic parenchyma (13). Two readers independently categorized the 63 time–density curves into 4 different morphologies: normal wash-in and wash-out (A), low wash-in followed by plateau (B), low wash-in followed by faint wash-out (C) and high wash-in and wash-out (D). Interobserver agreement was calculated with kappa statistics. Fisher test was used to calculate sensitivity, specificity, positive (PPV) and negative (NPV) predictive values for each type of curve.

Results

Interobserver agreement was very good (Kappa = 0.849). Curve A had 94.4% sensitivity, 91.1% specificity, 80.95% PPV, 97.6% NPV for ‘normal parenchyma’. Curve B had 74.19% sensitivity, 93.75% specificity, 92% PPV, 78.95% NPV in diagnosing ‘adenocarcinoma’. Curve C had 45.45% sensitivity, 84.62% specificity, 38.46% PPV, 88% NPV for ‘chronic pancreatitis’. Curve D had 100% sensitivity, 98.33% specificity, 75% PPV, 100% NPV for ‘endocrine tumor’.

Conclusions

The morphology of MDCT perfusion time–density curves appears to be useful in characterizing pancreatic lesions, and might help overcome the differences in scan and postprocessing techniques.  相似文献   

11.

Objective

The aim of this study is to assess the diagnostic value of direct MR arthrography compared to conventional MR imaging in the diagnosis of different pathologic entities affecting the triangular fibrocartilage.

Subjects and methods

This study included 51 patients complaining of chronic wrist pain. Conventional MRI and MR arthrography (MRA) was done for all cases.

Results

A comparison of the sensitivity of conventional MRI versus MRA was done by correlating the final diagnosis of each modality with the results of arthroscopy. MRI revealed a sensitivity (SEN) of 88.5%, specificity (SPE) of 100%, positive predictive value (PPV) of 100%, and a negative predictive value (NPV) of 69.2%, with an overall accuracy (ACC) of 90.9%, while MRA revealed a SEN of 94.2%, SPE of 100%, PPV of 100%, NPV of 81.8%, and ACC of 95.5%.

Conclusion

MR arthrography is a potent additional tool facilitating the diagnosis of different pathologic entities affecting the triangular fibrocartilage requiring surgical intervention and help to reduce arthroscopic interventions.  相似文献   

12.

Purpose

The purpose of the study was to compare the diagnostic value of color Doppler ultrasonography (CDUS) and multidetector computed tomography (MDCT) angiography against that of digital subtraction angiography (DSA) or surgery in the evaluation of failing hemodialysis arteriovenous fistulas (AVFs).

Materials and methods

CDUS and MDCT angiography were performed with 41 patients (24 men, 17 women; mean age 55.8) with dysfunctional hemodialysis fistulas. The presence of stenosis, thrombosis, aneurysm, pseudoaneurysm and seroma were recorded. The sensitivity, specificity, positive and negative predictive values (PPV and NPV) and accuracy of CDUS and MDCT angiography were calculated both individually and in combination for the detection of vascular segments with significant stenosis, thrombosis, aneurysms, pseudoaneurysms, perivascular complications and stenosis subgroups.

Results

Sixty-four segmental lesions were diagnosed by DSA or surgery. Sensitivity, specificity, PPV, NPV and accuracy of CDUS for all vascular tree lesions were 85.9%, 99.2%, 96.4%, 96.7% and 94.5%, respectively. For MDCT angiography the figures were 96.8%, 99.6%, 98.4%, 99.2% and 98.5%, respectively. When both tests were used in combination, sensitivity, specificity, PPV, NPV and accuracy for all vascular tree lesions rose to 100%.

Conclusion

Combined use of MDCT and CDUS for diagnosis of AVF dysfunctions is of equivalent value to surgery or DSA, a gold standard technique.  相似文献   

13.

Aim of the work

To evaluate the value of real-time ultrasound elastography (RTE) in differentiating benign from malignant breast masses.

Materials and methods

This study included, whether palpable or non-palpable, 145 sonographically proven breast masses in 121 patients, imaged by conventional B-mode US, color-flow Doppler US and RTE with histopathological analysis considered as the golden standard reference.

Results

Lesions were differentiated into benign and malignant by conventional B-mode US (79; 45.5% and 66; 54.5%, respectively), RTE (80; 55.2% and 65; 44.8% respectively), and histopathology (82; 56.6% and 63; 43.4%, respectively). The mean difference in the mass size was significant between B-mode US and RTE in malignant masses (P = 0.002), while not significant among benign masses (P = 0.153). The B-mode US depicted sensitivity of 92.06%, specificity of 90.24%, PPV of 87.88%, NPV of 93.67% and accuracy of 91.03%, while the RTE showed sensitivity of 98.41%, specificity of 96.34%, PPV of 95.38%, NPV of 98.75% and accuracy of 97.24%.

Conclusion

Combined use of RTE can complement conventional B-mode US with improving its diagnostic performance in differentiating breast lesions with subsequent reduction in the rate of unnecessary biopsies in benign lesions.  相似文献   

14.

Objective

To evaluate the value of hip MR for diagnosing acetabular labrum tears, and to further compare the diagnostic performances of conventional MR with MR arthrography in acetabular labrum tears.

Methods

90 patients undergoing both hip MR examination and subsequent hip arthroscopy were retrospectively evaluated. Of these patients, 34 accepted both conventional MR and MR arthrography; while the other 56 only underwent conventional MR examination. All hip MR images were independently reviewed by two radiologists, and further compared with the results of hip arthroscopy.

Results

59 of 90 patients were confirmed with acetabular labral tears by hip arthroscopy and 31 without tears. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of conventional MR for evaluating the acetabular labral tears were 61.0%, 77.4%, 83.7% and 51.1% (radiologist A), and 66.1%, 74.2%, 82.9% and 53.4% (radiologist B), respectively, with good consistency between the two observers (K = 0.645). The sensitivity, specificity, PPV and NPV of MR arthrography for assessing the acetabular labral tears were 90.5%, 84.6%, 90.5% and 84.6% (radiologist A), and 95.2%, 84.6%, 90.9% and 91.7% (radiologist B), respectively, with excellent good consistency between the two observers (K = 0.810). The sensitivity and NPV of MR arthrography for diagnosing the acetabular labral tears were significantly higher than those of conventional MR (both P < 0.05).

Conclusion

Hip MR arthrography is a reliable evaluation modality for diagnosing the acetabular labral tears, and its diagnostic performance is superior to that of conventional MR at 3.0 T.  相似文献   

15.

Purpose

To prospectively assess the performance of teleradiology-based CT colonography to screen a population group of an island, at average risk for colorectal cancer.

Materials and methods

A cohort of 514 patients living in Madeira, Portugal, was enrolled in the study. Institutional review board approval was obtained and all patients signed an informed consent. All patients underwent both CT colonography and optical colonoscopy. CT colonography was interpreted by an experienced radiologist at a remote centre using tele-radiology. Per-patient sensitivity, specificity, positive (PPV) and negative (NPV) predictive values with 95% confidence intervals (95%CI) were calculated for colorectal adenomas and advanced neoplasia ≥6 mm.

Results

510 patients were included in the study. CT colonography obtained a per-patient sensitivity, specificity, PPV and, NPV for adenomas ≥6 mm of 98.11% (88.6–99.9% 95% CI), 90.97% (87.8–93.4% 95% CI), 56.52% (45.8–66.7% 95% CI), 99.75% (98.4–99.9% 95% CI). For advanced neoplasia ≥6 mm per-patient sensitivity, specificity, PPV and, NPV were 100% (86.7–100% 95% CI), 87.07% (83.6–89.9% 95% CI), 34.78% (25.3–45.5% 95% CI) and 100% (98.8–100% 95% CI), respectively.

Conclusion

In this prospective trial, teleradiology-based CT colonography was accurate to screen a patient cohort of a remote island, at average risk for colorectal cancer.  相似文献   

16.

Objectives

To explore the value of virtual touch tissue image (VTI) and virtual touch tissue quantification (VTQ) in the differential diagnosis of thyroid nodules.

Methods

One-hundred and seven patients with 113 thyroid nodules were performed conventional ultrasound and acoustic radiation force impulse (ARFI) elastography. The stiffness of the nodules on virtual touch tissue image (VTI) was graded, and the area ratios (AR) of nodules on VTI images versus on B-mode images were calculated. Shear wave velocity (SWV) within the thyroid nodules were measured using virtual touch tissue quantification (VTQ) technique. The pathological diagnosis as the gold standard draws the receiver-operating characteristic curve (ROC) to find the cut-off point of VTI grades, AR and SWV to predict thyroid cancer.

Results

The difference in VTI grades of malignant and benign nodules was statistically significant (P < 0.05), as well as in AR and SWV. There was no significant difference in the AR of nodules or the SWV of nodules in benign group or in malignant group. The sensitivity, specificity, accuracy, positive predictive value (PPV), and negative predictive value (NPV) of VTI grades, AR, and SWV in the differential diagnosis of thyroid nodules were calculated. There was no significant difference in diagnostic accuracy among the three methods.

Conclusion

VTI grades, AR of nodules on VTI images versus on B-mode images and SWV within the nodules can help the differential diagnosis of thyroid nodules.  相似文献   

17.

Objective

Evaluation of the diagnostic efficacy and interobserver agreement of Q-elastography in the differentiation of benign from malignant thyroid nodules.

Methods

A total of 344 thyroid nodules in 288 patients were examined with grey-scale and colour Doppler ultrasound (CDUS) and Q-elastography by two independent operators. Nodules with hypoechogenicity, poorly defined margins, microcalcifications, and intralesional vascularity were classified as suspicious. Diagnostic performances of CDUS features and Q-elastography for predicting thyroid malignancy were estimated using ROC analysis. Cytology or histopathology was the reference standard. Interobserver agreement in the evaluation of CDUS and Q-elastography was assessed using Cohen's k-statistic.

Results

Q-elastography showed excellent diagnostic performance for the prediction of thyroid malignancy, with sensitivity of 93 % and specificity of 92 % for operator 1 (best cutoff at 2.02), and sensitivity of 84 % and specificity of 79 % for operator 2 (best cutoff at 1.86). Performance of Q-elastography was superior to that of CDUS. Reproducibility of the findings was excellent for both Q-elastography and CDUS features as assessed with Cohen's k, which was highest for strain ratio measurements (0.95) and lowest for the echogenicity score (0.83).

Conclusions

Q-elastography showed excellent performance. It is a valid and reproducible diagnostic method as well as a promising tool for identifying suspicious solid thyroid nodules needing cytological assessment and surgery.

Key Points

? Elastography is an additional tool for optimal characterisation of malignant thyroid nodules. ? The use of semiquantitative elastographic evaluation increases the diagnostic performance, ? The interobserver agreement of quantitative elastography can be considered to be good.  相似文献   

18.

Objective

To evaluate the contribution of power Doppler ultrasonography (PDUS) to breast imaging reporting and data system ultrasonography (BI-RADS US) categorization of solid breast masses.

Materials and methods

Totally 94 solid lesions with histopathological results in 49 patients were included in the study. US features of the lesions were classified according to American College of Radiologists (ACR) BI-RADS US lexicon. Lesions were evaluated qualitatively according to their PDUS properties and quantitatively with spectral analysis. Hypervascularity, penetration of vessels into the mass or branching-disordered course and resistivity index values higher than 0.85 were accepted as probable malignant criteria.

Results

Fifty-five of 94 lesions were benign (58.5%), while 39 (41.5%) were malignant histopathologically. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of US and PDUS in the diagnosis of malignant lesions were 100%, 58.2%, 62.9%, 100% and 71.8%, 81.8%, 73.7%, 80.4%, respectively. Criteria used for the distinction of malignant and benign lesions like number of vessels (p < 0.05), distribution of tumoral vessels, morphology of vessels and resistivity index values higher than 0.85 showed statistically significant difference (p < 0.001). When sonographic findings were combined with PDUS and spectral analysis findings, sensitivity, specificity, PPV and NPV were 100%, 52.7%, 60% and 100%, respectively.

Conclusion

PDUS and spectral analysis have no contribution to BI-RADS US. For the spectral analysis, when RI value is one or greater, malignancy risk significantly increases.  相似文献   

19.

Objective

This study aims to evaluate the clinical value of ultrasound elastography (USE) in providing information on the nature of the thyroid nodules. This was performed using the elastography score and strain ratio in differentiating thyroid benign and malignant nodules and the histopathological examination was used as the diagnostic standard of reference.

Methods

We examined 84 thyroid nodules in 62 patients with ultrasound elastography. Elastography score was assigned based on a four-point scale according to the classification proposed by Itoh et al. with a score of 1 (low stiffness over the entire nodule) to a score of 4 (high stiffness over the entire nodule). Thyroid strain ratio (normal tissue to lesion strain ratio) was calculated. Histopathological results were the standard reference. The area under the curve (AUC) and the best cut-off point were both obtained using receiver-operating characteristic (ROC) curve analysis. The sensitivity, specificity, and accuracy of both techniques were calculated.

Results

Fifty-four of the 84 nodules had scores of 1 and 2, and 50 of these nodules were diagnosed histopathologically as benign. Thirty of the 84 nodules had a score of 3 and 4, and 21 of these nodules were diagnosed histopathologically as malignant. The scores of 1 and 2 with Itoh criteria were significantly seen in benign nodules, whereas, scores of 3 and 4 were significantly seen in malignant nodules (p < 0.05) with sensitivity 84%, specificity 84.7%, PPV 70%, NPV 92.6% and accuracy 84.5%. The mean SR for the benign nodules and malignant ones was significantly different (2.92 ± 0.96 vs. 4.53 ± 0.82, p < 0.001). With ROC analysis, the best cut-off strain ratio point was 3.5 for differentiating benign and malignant nodules with area under the curve (AUC) = 0.87 (0.8–0.95). The sensitivity of the strain ratio was 88%, while the specificity was 86.4%, PPV = 73.3%, NPV = 94.4% and accuracy = 86.9%.

Conclusions

Both the elastographic score and strain ratio are higher in malignant nodules than those in benign ones. Ultrasound elastography can provide quantitative information on thyroid nodule helping in differentiating benign and malignant ones.  相似文献   

20.

Objective

To detect if strain ultrasound elastography and strain ratio have additional value to the conventional grey scale ultrasound in predicting thyroid malignancy.

Patients and methods

This study included 92 thyroid nodules from 62 patients (the mean age was 40.64?±?13.93). Morphologic aspects of the thyroid nodule in conventional grey scale ultrasonography and elastographic examinations with elastography score and strain ratio (SR) were performed for all nodules. The final diagnosis was confirmed by fine needle aspiration biopsies in 72 nodules and by excisional biopsies in 20 nodules.

Results

We found that combination of both conventional ultrasound and strain elastography score have the best diagnostic performance with sensitivity, specificity, PPV, NPV and accuracy accounting for 80%, 97%, 57%, 99% and 96% respectively. The means SR for benign nodules (1.37?±?0.56) was significantly lower than that for malignant nodules (3.0?±?0.71) [p-value .003].The optimal SR cutoff is 2.5 with estimated 80% sensitivity, 98% specificity, PPV 67%, NPV 99% and accuracy 97%.

Conclusion

The clinical application of elastography score and SR should be carried out hand in hand with conventional sonographic assessment of thyroid nodules to achieve the best diagnostic performance.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号