首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到19条相似文献,搜索用时 14 毫秒
1.
Knowledge about fallopian tube disease is essential in the assessment of the pelvis in female patients. Primary and secondary changes in the tubes vary widely, regardless of whether associated changes in the ovaries are present. Ultrasonography is the initial technique in the study of adnexal disease because it is very sensitive and widely available; however, MRI is also very useful in this context because its high tissue resolution and anatomic detail make it more specific. The morphologic findings and the characteristics of the contents of the tubes on MRI enable a more accurate diagnosis or limit the differential diagnosis, helping to ensure that the most appropriate treatment is provided in each case.  相似文献   

2.
We present the case of a patient with a pacemaker and a sarcoma lung metastasis treated with microwave ablation. Although the treatment of tumours with microwave ablation is a successful and minimally invasive approach, there are concerns about the safety of this procedure for patients with implanted cardiac devices, such as a pacemaker. After careful planning between radiology and cardiology, microwave ablation was indicated in the patient since it is safer and shorter than the radiofrequency technique. The lesion was treated without complications. It is important to communicate the procedures performed, as well as any complications in order to formulate guidelines for the use of microwave ablation in patients with pacemakers.  相似文献   

3.
The incidence of contrast medium extravasation at the venipuncture site has increased with the generalized use of automatic injectors. Most extravasations only cause slight edema and erythema. Nevertheless, in some cases extravasation can result in severe skin lesions or even in compartment syndrome. Lesions caused by extravasation usually resolve spontaneously with conservative treatment. Although the complications of extravasation are well known, institutional protocols are normally lacking and the criteria for taking action and the type of treatment, whether based on the literature or personal preferences, tend to vary. In this article, we review the incidence, risk factors, clinical manifestations, and options for preventing and treating contrast medium extravasation in soft tissues. Finally, we present the protocol we use to manage extravasation at our hospital.  相似文献   

4.
A diaphragmatic hernia is defined as the protrusion of abdominal viscera into the thoracic cavity through a normal or pathological orifice. The herniated viscera compress the lungs, resulting in pulmonary hypoplasia and secondary pulmonary hypertension, which are the leading causes of neonatal death in patients with congenital diaphragmatic hernia. Congenital diaphragmatic hernia is diagnosed by sonography in routine prenatal screening. Although magnetic resonance imaging is fundamentally used to determine whether the liver is located within the abdomen or has herniated into the thorax, it also can provide useful information about other herniated structures and the degree of pulmonary hypoplasia. The aim of this article is to review the fetal magnetic resonance findings for congenital diaphragmatic hernia and the signs that enable us to establish the neonatal prognosis when evaluating pulmonary hypoplasia.  相似文献   

5.

Purpose

To implement in-phase and out-of-phase (IP/OP) techniques with Magnetization-Prepared Gradient Recalled Echo (MP-GRE) and to evaluate the feasibility and diagnostic image quality among pre and post-optimized MP-GRE sequences, including patients unable to cooperate with breath-hold requirements.

Materials and methods

Institutional review board approval with waiver of informed consent was obtained for this HIPAA-compliant retrospective study. Two groups of patients were included in the study, before and after optimization of MP-GRE parameters, with seventy-three (24 noncooperative/49 cooperative) and sixty-four (22 noncooperative/42 cooperative) consecutive patients, respectively. The motion-insensitive sequence used in this study was a single-shot 2D MP-GRE. Two radiologists qualitatively evaluated the sequences to identify the presence of phase cancellation artifact in OP images and to determine image quality, extent of artifacts (respiratory ghosting, bounce-point artifact, spatial misregistration and pixel graininess) and lesion conspicuity on the various sequences. The ability to visually detect liver steatosis and fatty adrenal adenomas was evaluated. Qualitative analyses were compared using the Wilcoxon and Mann-Whitney tests.

Results

There were statistically significant differences between all MP-GRE sequences concerning phase cancellation artifact (P<.0001) which was present in MP-GRE OP sequences and negligible to absent in the pre (IP1) and post-optimized (IP2) MP-GRE IP sequences, respectively, in all patients.Bounce point artifacts were significantly more pronounced in MP-GRE IP1 (P<.0001). Spatial misregistration was slightly more prominent in noncooperative patients with MP-GRE IP2 (P=.0027). MP-GRE OP and MP-GRE IP2 showed significantly higher overall image quality (P<.0001).MP-GRE sequences subjectively identified hepatic steatosis (n=20) and adrenal adenomas (n=5) based on signal loss from IP to OP sequence.

Conclusion

Single shot IP/OP MP-GRE is feasible and allows motion resistant imaging with adequate diagnostic image quality. This technique is able to provide IP and OP information in patients unable to suspend respiration.  相似文献   

6.

Objective

To compare the image quality and radiation dose in a group of patients undergoing coronary CT angiography using a 128-slice dual source helical CT scanner with high pitch alto and prospective acquisition with those in a group of patients with similar clinical characteristics undergoing coronary CT angiography using a 128-slice single-source CT scanner with prospective sequential acquisition.

Material and methods

We included 80 patients with heart rates ≤65 beats/min: 40 underwent sequential 128-slice single source CT with prospective synchronization and the other 40 underwent 128-slice dual source helical CT with high pitch and prospective synchronization. Two radiologists independently assessed the quality of the images of the coronary arteries on the 80 coronary CT angiograms: image quality was classified on a four-point scale in which 1 represented excellent and 4 deficient. The effective dose of radiation was also calculated.

Results

The clinical characteristics of the patients in the two groups were similar. The image quality obtained with dual source CT was significantly better than that obtained with single source CT (P=0.006). The mean effective dose of radiation in the group undergoing dual source CT was 36% lower than in the group undergoing single source CT (1.4±0.6 mSv vs. 2.2±0.9 mSv; P<0.01).

Conclusion

Although both sequential 128-slice single source CT with prospective acquisition and 128-slice dual source helical CT with high pitch and prospective acquisition provide good image quality and low effective doses of radiation, 128-slice dual source helical CT with prospective acquisition provides better image quality and results in a lower effective dose of radiation.  相似文献   

7.

Objective

To review and classify the interval cancers found in the Principality of Asturias's Breast Cancer Screening Program (PDPCM). A secondary objective was to determine the histological characteristics, size, and stage of the interval cancers at the time of diagnosis.

Material and methods

We included the interval cancers in the PDPCM in the period 2003-2007. Interval cancers were classified according to the breast cancer screening program protocol, with double reading without consensus, without blinding, with arbitration. Mammograms were interpreted by 10 radiologists in the PDPCM.

Results

A total of 33.7% of the interval cancers could not be classified; of the interval cancers that could be classified, 40.67% were labeled true interval cancers, 31.4% were labeled false negatives on screening, 23.7% had minimal signs, and 4.23% were considered occult. A total of 70% of the interval cancers were diagnosed in the year of the period between screening examinations and 71.7% were diagnosed after subsequent screening. A total of 76.9% were invasive ductal carcinomas, 61.1% were stage II when detected, and 78.7% were larger than 10 mm when detected.

Conclusions

The rate of interval cancers and the rate of false negatives in the PDPCM are higher than those recommended in the European guidelines. Interval cancers are diagnosed later than the tumors detected at screening. Studying interval cancers provides significant training for the radiologists in the PDPCM.  相似文献   

8.
Plain chest films are a fundamental tool in the practice of medicine. The apparent simplicity of plain chest films sometimes leads us to forget that interpreting them correctly can provide very valuable information, especially if the interpretation is grounded in key clinical information.  相似文献   

9.

Objective

To describe cases of obstetric hemorrhage that have called for selective intra-arterial embolization and the different embolization techniques used. To assess the clinical outcomes and postprocedural fertility.

Material and methods

We studied 27 women with obstetric hemorrhage. In 24 patients, embolization was performed by catheterizing both uterine arteries and in 2 patients only one uterine artery was catheterized (pseudoaneurysm). The materials used for embolization consisted of Spongostan in 17/27, particles in 9/27, and coils in 1/27. Clinical follow-up included an analysis of early and late complications and of postprocedural fertility.

Results

Hemorrhage was classified as primary (25/27) or secondary (2/27).The cause of bleeding was vaginal delivery (20), cesarean sections (5), abortion (1), and cervical ectopic pregnancy (1).The initial technical success rate was 100% and the clinical success rate was 92.6% (25 of the 27 patients).Bleeding ceased and the outcome was satisfactory in 25 patients. During clinical follow-up ranging from one to seven years, 23 patients had normal menstruation and 6 patients completed 7 full-term pregnancies.

Conclusion

Intra-arterial embolization for obstetric hemorrhage leads to good outcomes and few complications and it preserves fertility.  相似文献   

10.

Objective

To identify factors that might explain why a prostate with a Gleason score (GS) <7 in the biopsy specimen can turn out to have a GS ≥7 in the surgical specimen.

Material and methods

We compared the GS of biopsy specimens with the GS of surgical specimens in 185 patients who underwent surgery for prostate cancer. We calculated the sensitivity, specificity, and predictive values for the GS of the biopsy specimens. We used Cohen's kappa to determine the degree of concordance between a GS of <7 and ≥7 for the biopsy specimen and the surgical specimen. Age, a family history of prostate cancer, total prostate-specific antigen (tPSA), digital rectal examination, prostate structure and volume, and the number of biopsy cores (biopsy scheme) were analyzed using multivariable logistic regression.

Results

Histological study of biopsy specimens yielded high sensitivity (98%) but low specificity (49%) for GS ≤6 and low sensitivity (35, 26%) and high specificity (93, 99%) for GS=7 and GS ≥7, respectively. Cohen's kappa for the GS from the biopsy and surgical specimens was 0.43 (95% CI=30-56%). The biopsy scheme was the only predictor of discordance in the GS between the two techniques. Among the other variables included in the model, only tPSA showed a slightly significant association. Taking a scheme with less than 7 cores as a reference, we found no difference with 8 to 9 cores but we did find a difference with 10 to 11 cores and with 12 or more cores, with a prevalence ratio of 0.138 (95% CI=0.030-0.513) and 0.277 (95% CI=0.091-0.806), respectively.

Conclusion

The GS of the biopsy depends on the scheme. This factor must be taken into account when choosing a treatment option in patients with low tumor grade in biopsy specimens.  相似文献   

11.
We present the case of a nine-year-old boy with Tourette syndrome and reading disorder with a history of a severe infectious process in the late neonatal period. Brain MRI showed a left parietal malacotic cavity and diffusion tensor imaging and tractography showed a striking disruption of the white matter bundle that joins the left parietal region with the ipsilateral frontal region with involvement of the left superior longitudinal fasciculus and of the left arcuate fasciculus. Although Tourette syndrome and reading disorder are fundamentally hereditary neuropsychiatric disorders, they can also occur secondary to cerebral alterations like those existing in this boy. The introduction of modern neuroimaging techniques in patients with neuropsychiatric disorders (or the risk of developing them) can be very useful in the diagnosis and prognosis in the future.  相似文献   

12.

Objective

We used an animal model to analyze the reproducibility and accuracy of certain biomarkers of bone image quality in comparison to a gold standard of computed microtomography (μCT).

Material and methods

We used magnetic resonance (MR) imaging and μCT to study the metaphyses of 5 sheep tibiae. The MR images (3 Teslas) were acquired with a T1-weighted gradient echo sequence and an isotropic spatial resolution of 180 μm. The μCT images were acquired using a scanner with a spatial resolution of 7.5 μm isotropic voxels. In the preparation of the images, we applied equalization, interpolation, and thresholding algorithms. In the quantitative analysis, we calculated the percentage of bone volume (BV/TV), the trabecular thickness (Tb.Th), the trabecular separation (Tb.Sp), the trabecular index (Tb.N), the 2 D fractal dimension (D2D), the 3 D fractal dimension (D3D), and the elastic module in the three spatial directions (Ex, Ey and Ez).

Results

The morphometric and mechanical quantification of trabecular bone by MR was very reproducible, with percentages of variation below 9% for all the parameters. Its accuracy compared to the gold standard (μCT) was high, with errors less than 15% for BV/TV, D2D, D3D, and Eappx, Eappy and Eappz.

Conclusions

Our experimental results in animals confirm that the parameters of BV/TV, D2D, D3D, and Eappx, Eappy and Eappz obtained by MR have excellent reproducibility and accuracy and can be used as imaging biomarkers for the quality of trabecular bone.  相似文献   

13.

Objective

To study the differences in vascular image quality, bone subtraction, and dose of radiation of dual energy CT angiography of the supraaortic trunks using different tube voltages.

Material and methods

We reviewed the CT angiograms of the supraaortic trunks in 46 patients acquired with a 128-slice dual source CT scanner using two voltage protocols (80/140 kV and 100/140 kV). The “head bone removal” tool was used for postprocessing. We divided the arteries into 15 segments. In each segment, we evaluated the image quality of the vessels and the effectiveness of bone removal in multiplanar reconstructions (MPR) and in maximum intensity projections (MIP) with each protocol, analyzing the trabecular and cortical bones separately. We also evaluated the dose of radiation received.

Results

Of the 46 patients, 13 were studied using 80/140 kV and 33 with 100/140 kV. There were no significant differences between the two groups in age or sex. Image quality in four segments was better in the group examined with 100/140 kV. Cortical bone removal in MPR and MIP and trabecular bone removal in MIP were also better in the group examined with 100/140 kV. The dose of radiation received was significantly higher in the group examined with 100/140 kV (1.16 mSv with 80/140 kV vs. 1.59 mSv with 100/140 kV).

Conclusion

Using 100/140 kV increases the dose of radiation but improves the quality of the study of arterial segments and bone subtraction.  相似文献   

14.
We present the cases of two men with isolated spontaneous dissection of visceral arteries diagnosed by multidetector CT. In the first patient, dissection of the celiac trunk was associated with periarterial changes. In the second patient, dissection of the superior mesenteric artery was associated with stenosis at the root of the celiac trunk. Both patients presented with acute pain, which was more intense and longer lasting in the first patient. Aortic dissection was suspected clinically in both patients.  相似文献   

15.

Objectives

To evaluate the sensation of pleasantness perceived by patients attended in the radiology department in response to decorative elements hung on the walls in the waiting rooms and in the hallways of the imaging area.

Material and methods

The material resources comprised works of art in the form of “magic windows” representing scenes from nature installed on the ceilings and walls of the waiting area and hallways of the imaging area. Patients were given a brief questionnaire with general data and questions (sadness-cheerfulness, coldness-warmth, darkness-light, and pessimism-optimism) about their perception of the decorative elements.

Results

Of the 150 questionnaires collected, 142 were filled out correctly. The overall health of these patients was good in 84 (56%), not bad in 58 (39%), and poor in 8 (5%). The idea seemed very good to 70 patients (47%), good to 58 (39%), not bad to 8 (5%), indifferent to 11 (7%), bad to 1 (1%), and very bad to 2 (1%). As far a patients’ mobility, 119 patients (79%) walked into the department, 18 (12%) were wheeled in on beds, and 13 (9%) needed wheelchairs.

Conclusions

We found a high level of satisfaction with the decorative elements.  相似文献   

16.
Radiology with oral contrast, or enteroclysis, have traditionally been the techniques of choice in the examination of the small intestine, due to the excellent visualisation of the mucosal pattern. However, the absence of extra-luminal information and the use of ionising radiation have replaced these examinations with sectional techniques which enable the abdominal cavity to be viewed with good resolution. Magnetic resonance enterography is a simple technique, with no ionising radiation, provided quality images, distends the intestinal lumen well by the administration of non-reabsorbable oral substances, minimises peristalsis, and establishes a protocol which includes sequences with intravenous contrast. These properties can be used in patients with Crohn's disease, achieving good diagnostic precision in the assessment of activity and monitoring of treatment, in intestinal obstruction, in the suspicion of small intestine tumours, and in paediatric patients due to it being harmless.  相似文献   

17.
The increase in the frequency of abdominal aortic aneurysms (AAA) and the widely accepted use of endovascular aneurysm repair (EVAR) as a first-line treatment or as an alternative to conventional surgery make it necessary for radiologists to have thorough knowledge of the pre- and post-treatment findings. The high image quality provided by multidetector computed tomography (MDCT) enables CT angiography to play a fundamental role in the study of AAA and in planning treatment.  相似文献   

18.

Objectives

To evaluate the recanalization rate and clinical outcome three months after endovascular treatment for vertebrobasilar occlusion before the placement of stentrievers.

Material and methods

We reviewed all cases of basilar thrombosis treated with endovascular techniques at our center. We reviewed the clinical outcomes with the main objective of determining the recanalization rate and the secondary objective of evaluating the outcome using the modified Rankin scale (mRS) three months after treatment. We assessed clinical and angiographic variables and correlated them with outcome and complications.

Results

We reviewed a total of 27 consecutive patients (mean age, 58.1 ± 15.5 y; median National Institutes of Health Stroke Scale (NIHSS), 21, interquartile range, 18-29; median Glasgow coma score (GCS) 7, interquartile range, 4-9.5). The mean time between the onset of symptoms and endovascular treatment was 26.3 ± 41.7 hours. Complete or partial recanalization was achieved in 23 (85.1%) patients. Three months after treatment, 16 (59.2%) had died and 6 (22.2%) had good outcome (mRS ≤ 2).

Conclusion

Endovascular treatment achieved a high rate of recanalization of occlusions of the basilar artery. Nevertheless, a high percentage of the patients did not have a good outcome. New materials might improve the prognosis in these patients.  相似文献   

19.
设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号