1.

Objective

To compare the image quality and radiation dose in a group of patients undergoing coronary CT angiography using a 128-slice dual source helical CT scanner with high pitch alto and prospective acquisition with those in a group of patients with similar clinical characteristics undergoing coronary CT angiography using a 128-slice single-source CT scanner with prospective sequential acquisition.

Material and methods

We included 80 patients with heart rates ≤65 beats/min: 40 underwent sequential 128-slice single source CT with prospective synchronization and the other 40 underwent 128-slice dual source helical CT with high pitch and prospective synchronization. Two radiologists independently assessed the quality of the images of the coronary arteries on the 80 coronary CT angiograms: image quality was classified on a four-point scale in which 1 represented excellent and 4 deficient. The effective dose of radiation was also calculated.

Results

The clinical characteristics of the patients in the two groups were similar. The image quality obtained with dual source CT was significantly better than that obtained with single source CT (P=0.006). The mean effective dose of radiation in the group undergoing dual source CT was 36% lower than in the group undergoing single source CT (1.4±0.6 mSv vs. 2.2±0.9 mSv; P<0.01).

Conclusion

Although both sequential 128-slice single source CT with prospective acquisition and 128-slice dual source helical CT with high pitch and prospective acquisition provide good image quality and low effective doses of radiation, 128-slice dual source helical CT with prospective acquisition provides better image quality and results in a lower effective dose of radiation.  相似文献   

2.

Purpose

The purpose of the study was to compare 100 kV and 120 kV prospective electrocardiograph (ECG)-triggered axial coronary 64-detector CT angiography (64-MDCTA) in soft plaque diagnosis.

Materials and methods

Coronary artery models (n = 5) with artificial soft plaques (−32 HU to 53 HU at 120 kV) with three stenosis levels (25%, 50% and 75%) on a cardiac phantom (mimicking slim patient's environment) were scanned in heart rates of 55, 60 and 65 beats per minute (bpm). Four kinds of intracoronary enhancement (205 HU, 241 HU, 280 HU and 314 HU) were simulated. The soft plaque density and the measurement error of stenosis (in percentage), evaluated by two independent observers, were compared between 100 kV and 120 kV. The radiation dose was estimated.

Results

Interobserver correlation of the measurement was excellent (density; r = 0.95 and stenosis measure; r = 0.97). Neither the density of soft plaque nor the measurement error of stenosis was different between 100 kV and 120 kV (p = 0.22 and 0.08). The estimated radiation doses were 2.0 mSv and 3.3 mSv (in 14 cm coverage) on 100 kV and 120 kV prospective ECG-triggered axial scans, respectively.

Conclusion

The 100 kV prospective ECG-triggered coronary MDCTA has comparable performance to 120 kV coronary CTA in terms of soft plaque densitometry and measurement of stenosis, with a reduced effective dose of 2 mSv.  相似文献   

3.

Objectives

To determine the impact of hybrid iterative reconstruction (HIR) on image quality in 80 kV CT pulmonary angiography (CTPA) in comparison to filtered-back-projection (FBP).

Methods

Fifty patients (body weight <80 kg) with suspected pulmonary embolism (PE) underwent CTPA at 80 kV (mean CTDIvol, 2.3 mGy; effective dose, 1.2 mSv). The raw data were reconstructed using FBP and three increasing HIR levels. Two radiologists assessed image quality and image noise. Conspicuity of PE was assessed in central, segmental, and subsegmental arteries. CT attenuation of pulmonary arteries, objective image noise (OIN) and contrast-to-noise ratios (CNR) were assessed.

Results

With each HIR level, a significant decrease in subjective and objective image noise was achieved with a reduction of OIN up to 46% in comparison with FBP. CNR significantly increased with the application of HIR compared to FBP. Image quality was rated significantly higher at HIR reconstructions in comparison with FBP. Diagnosis of PE was feasible with each data set; however, conspicuity of central and segmental PE significantly improved with the use of HIR.

Conclusions

Eighty kilovoltage CTPA with HIR provides improved image quality and conspicuity of pulmonary embolism enabling low dose CTPA protocols close to 1 mSv in patients weighing less than 80 kg.  相似文献   

4.

Purpose

To implement in-phase and out-of-phase (IP/OP) techniques with Magnetization-Prepared Gradient Recalled Echo (MP-GRE) and to evaluate the feasibility and diagnostic image quality among pre and post-optimized MP-GRE sequences, including patients unable to cooperate with breath-hold requirements.

Materials and methods

Institutional review board approval with waiver of informed consent was obtained for this HIPAA-compliant retrospective study. Two groups of patients were included in the study, before and after optimization of MP-GRE parameters, with seventy-three (24 noncooperative/49 cooperative) and sixty-four (22 noncooperative/42 cooperative) consecutive patients, respectively. The motion-insensitive sequence used in this study was a single-shot 2D MP-GRE. Two radiologists qualitatively evaluated the sequences to identify the presence of phase cancellation artifact in OP images and to determine image quality, extent of artifacts (respiratory ghosting, bounce-point artifact, spatial misregistration and pixel graininess) and lesion conspicuity on the various sequences. The ability to visually detect liver steatosis and fatty adrenal adenomas was evaluated. Qualitative analyses were compared using the Wilcoxon and Mann-Whitney tests.

Results

There were statistically significant differences between all MP-GRE sequences concerning phase cancellation artifact (P<.0001) which was present in MP-GRE OP sequences and negligible to absent in the pre (IP1) and post-optimized (IP2) MP-GRE IP sequences, respectively, in all patients.Bounce point artifacts were significantly more pronounced in MP-GRE IP1 (P<.0001). Spatial misregistration was slightly more prominent in noncooperative patients with MP-GRE IP2 (P=.0027). MP-GRE OP and MP-GRE IP2 showed significantly higher overall image quality (P<.0001).MP-GRE sequences subjectively identified hepatic steatosis (n=20) and adrenal adenomas (n=5) based on signal loss from IP to OP sequence.

Conclusion

Single shot IP/OP MP-GRE is feasible and allows motion resistant imaging with adequate diagnostic image quality. This technique is able to provide IP and OP information in patients unable to suspend respiration.  相似文献   

5.

Objective

To determine whether there is iron overload by calculating the T2* value in the liver and myocardium in patients with secondary haemochromatosis. To analyse the correlation of the values obtained with the iron levels in blood, with the liver iron concentration (LIC) calculated using magnetic resonance (MR) imaging, and the correlation between them.

Material and methods

A total of 16 patients (13 males, 3 females), with a mean age of 61 years, were included and evaluated in the years 2008 and 2009. Fifteen of them had received multiple transfusions, and one was diagnosed with hereditary sideroblastic anaemia.The measurements included, blood ferritin, LIC by MRI, cardiac function using MRI and the T2* value by means of multi-echo sequences in the liver (TR/TE1/ΔTE/No of echos/α: 21/1,18/1.0/20/35°) and myocardium (26/1.04/0.8/30/60°). A correlation-regression analysis was performed by comparing the cardiac and liver T2* values with the ferritin, LIC and between each of them.

Results

A total of 13 patients had ferritin values greater than 1000 ng/ml (median/minimum/maximum: 1762/294/3785 ng/ml). An increased LIC greater than 80 μmol/g (median/minimum/maximum: 125.4/41.2/241.5 μmol/g) was observed in 13 patients. In all cases cardiac function was conserved, and in 15 cases the liver T2* value was less than 6.3 ms. The myocardium T2* value was less than 20 ms. in only one case. A high correlation was observed between the liver T2* values and the LIC (r: -0.912). The correlation was statistically significant between the liver T2* value and ferritin (r: -0.541). The correlations between myocardium T2* and ferritin, myocardium T2* and LIC, and myocardium T2* and liver T2* were not statistically significant.

Conclusions

The liver T2* showed a high correlation with LIC and a statistically significant correlation with ferritin. No association was observed between the myocardium T2* values and ferritin in blood, the LIC or the liver T2* value.  相似文献   

6.

Objectives

To evaluate an automated attenuation-based kV-selection in computed tomography of the chest in respect to radiation dose and image quality, compared to a standard 120 kV protocol.

Materials and methods

104 patients were examined using a 128-slice scanner. Fifty examinations (58 ± 15 years, study group) were performed using the automated adaption of tube potential (100–140 kV), based on the attenuation profile of the scout scan, 54 examinations (62 ± 14 years, control group) with fixed 120 kV. Estimated CT dose index (CTDI) of the software-proposed setting was compared with a 120 kV protocol. After the scan CTDI volume (CTDIvol) and dose length product (DLP) were recorded. Image quality was assessed by region of interest (ROI) measurements, subjective image quality by two observers with a 4-point scale (3 – excellent, 0 – not diagnostic).

Results

The algorithm selected 100 kV in 78% and 120 kV in 22%. Overall CTDIvol reduction was 26.6% (34% in 100 kV) overall DLP reduction was 22.8% (32.1% in 100 kV) (all p < 0.001). Subjective image quality was excellent in both groups.

Conclusion

The attenuation based kV-selection algorithm enables relevant dose reduction (∼27%) in chest-CT while keeping image quality parameters at high levels.  相似文献   

7.

Objective

We used an animal model to analyze the reproducibility and accuracy of certain biomarkers of bone image quality in comparison to a gold standard of computed microtomography (μCT).

Material and methods

We used magnetic resonance (MR) imaging and μCT to study the metaphyses of 5 sheep tibiae. The MR images (3 Teslas) were acquired with a T1-weighted gradient echo sequence and an isotropic spatial resolution of 180 μm. The μCT images were acquired using a scanner with a spatial resolution of 7.5 μm isotropic voxels. In the preparation of the images, we applied equalization, interpolation, and thresholding algorithms. In the quantitative analysis, we calculated the percentage of bone volume (BV/TV), the trabecular thickness (Tb.Th), the trabecular separation (Tb.Sp), the trabecular index (Tb.N), the 2 D fractal dimension (D2D), the 3 D fractal dimension (D3D), and the elastic module in the three spatial directions (Ex, Ey and Ez).

Results

The morphometric and mechanical quantification of trabecular bone by MR was very reproducible, with percentages of variation below 9% for all the parameters. Its accuracy compared to the gold standard (μCT) was high, with errors less than 15% for BV/TV, D2D, D3D, and Eappx, Eappy and Eappz.

Conclusions

Our experimental results in animals confirm that the parameters of BV/TV, D2D, D3D, and Eappx, Eappy and Eappz obtained by MR have excellent reproducibility and accuracy and can be used as imaging biomarkers for the quality of trabecular bone.  相似文献   

8.

Objective

To review and classify the interval cancers found in the Principality of Asturias's Breast Cancer Screening Program (PDPCM). A secondary objective was to determine the histological characteristics, size, and stage of the interval cancers at the time of diagnosis.

Material and methods

We included the interval cancers in the PDPCM in the period 2003-2007. Interval cancers were classified according to the breast cancer screening program protocol, with double reading without consensus, without blinding, with arbitration. Mammograms were interpreted by 10 radiologists in the PDPCM.

Results

A total of 33.7% of the interval cancers could not be classified; of the interval cancers that could be classified, 40.67% were labeled true interval cancers, 31.4% were labeled false negatives on screening, 23.7% had minimal signs, and 4.23% were considered occult. A total of 70% of the interval cancers were diagnosed in the year of the period between screening examinations and 71.7% were diagnosed after subsequent screening. A total of 76.9% were invasive ductal carcinomas, 61.1% were stage II when detected, and 78.7% were larger than 10 mm when detected.

Conclusions

The rate of interval cancers and the rate of false negatives in the PDPCM are higher than those recommended in the European guidelines. Interval cancers are diagnosed later than the tumors detected at screening. Studying interval cancers provides significant training for the radiologists in the PDPCM.  相似文献   

9.

Objectives

Computed tomography angiography (CTA) is a well-accepted imaging modality to evaluate the supraaortic vessels. Initial reports have suggested that dual energy CTA (DE-CTA) can enhance diagnosis by creating bone-free data sets, which can be visualized in 3D, but a number of limitations of this technique have also been addressed. We sought to describe the performance of DE-CTA of the supraaortic vessels with a novel dual source CT system with special emphasis on image quality and post-processing related artifacts.

Materials and methods

Thirty-three patients underwent carotid CT angiography on a second generation dual source CT system. Simultaneous acquisitions of 100 and 140 kV data sets in arterial phase were performed. Two examiners evaluated overall bone suppression with a 3-point scale (1 = poor; 3 = excellent) and image quality regarding integrity of the vessel lumen of different vessel segments (n = 26) with a 5-point scale (1 = poor; 5 = excellent), CTA source data served as the reference.

Results

Excellent bone suppression could be achieved in the head and neck. Only minor bone remnants occurred, mean score for bone removal was 2.9. Mean score for vessel integrity was 4.3. Eight hundred fifty-seven vessel segments could be evaluated. Six hundred thirty-five segments (74%) showed no lumen alteration, 65 segments (7.6%) lumen alterations <10%, 27 segments (3.1%) lumen alterations >10% resulting in a total luminal reduction <50%, 17 segments (2%) lumen alterations of more than 10% resulting in a total luminal reduction >50%, and 113 segments (13.2%) showed a gap in the vessel course (100% total lumen reduction). Artificial gaps of the vessel lumen occurred in 28 vessel segments due to artifacts caused by dental hardware and in all but one (65) ophthalmic arteries.

Conclusions

Excellent bone suppression could be achieved, DE imaging with 100 and 140 kV lead to improved image quality and vessel integrity in the shoulder region than previously reported. The ophthalmic artery still cannot be adequately visualized.  相似文献   

10.

Purpose

To estimate the radiation dose and image quality of single-source (SSCT), high-pitch (HPCT), and dual-energy (DECT) protocols of a dual-source CT (DSCT) system for the examination of neck.

Materials and methods

180 patients were randomized to one of the three protocols: 60 patients (age: 55.4 ± 12 years; range: 44–84 years) were examined with a SSCT, other 60 (59.5 ± 16.4years; R: 40–85) with HPCT, and the last 60 (61.1 ± 14.9 years; R: 47–84) were examined with a DECT protocol. All examinations were performed using a DSCT system. The used protocols: Group-1 (SSCT: 120 kV; effective mAs: 185.4 ± 17.7), Group-2 (HPCT: 120 kV; eff. mAs: 97.7 ± 11.8), and Group-3 (DECT: 80 kV/140 kV with tin-filter; eff. mAs: 248.5 ± 25.7; 187 ± 21.2). A 100 ml iomeprol non-ionic contrast material was injected in to the patients during examination.

Results

Insignificant results were yielded regarding SNR and CNR between the groups (group-1 vs. 2: 0.3125, group-1 vs. 0.6W: 0.6875, group-2 vs. 0.6W: 0.3125), except DECT-80 (group-1 vs. 80 kV: 0.04289, group-2 vs. 80 kV: 0.025, group-0.6W vs.80 kV: 0.04567) and 140 kV data, moreover, qualitative analysis yielded the same results. Mean effective-dose was significantly lower (p < 0.05) in group-2 (1.06 ± 0.16 mSv) compared to group-1 (2.05 ± 0.22 mSv) or group-3 (1.76 ± 0.2 mSv). Single- and dual-energy comparison showed a significant difference (group-1 vs. 3: p = 0.00001 and group-2 vs. 3: p = 0.00001) for CTDIvol (percent difference: 16%, 64%) or DLP (PD: 15.5%, 50.5%).

Conclusion

Quantitative and qualitative analysis showed similar results for SSCT, HPCT, and DECT-0.6W datasets regarding quality. HPCT yielded lower dose compared to other groups, however, the DECT achieved a lower and significant dose difference from the SSCT protocol. HPCT and DECT can be used with similar image quality and lower radiation dose compared to SSCT for the scans and can be utilized to various clinical advantages.  相似文献   

11.

Purpose

To investigate the value of 4 different protocols for prospectively triggered 256-slice coronary computed tomography angiography (coronary CTA).

Methods

Two hundred and ten patients underwent prospectively triggered coronary CTA for suspected or known coronary artery disease (CAD). Patients with heart rate >75 bps before the scan despite ß-blocker administration and with arrhythmia were excluded. From January to September 2010, 60 patients underwent coronary CTA using a non-tailored protocol (120 kV; 200 mAs) and served as our ‘control’ group. From September 2010 to April 2012, based on the body mass index (BMI) of the examined patients (BMI subgroups of < 25; 25–28; 28–30, and ≥ 30 kg/m2) current tube voltage and tube current were: (1) slightly, (2) moderately or (3) strongly reduced, resulting into the 3 following BMI-adapted acquisition groups: (1) a ‘standard’ (100/120 kV; 100–200 mAs; n = 50), 2) a ‘low dose’ (100/120 kV; 75–150 mAs; n = 50), and 3) an ‘ultra-low dose’ (100/120 kV; 50–100 mAs; n = 50) protocol.

Results

Patients examined using the non-tailored protocol exhibited the highest radiation exposure (3.2 ± 0.4 mSv), followed by the standard (1.6 ± 0.7 mSv), low-dose (1.2 ± 0.6 mSv) and ultra-low dose protocol (0.7 ± 0.3 mSv) (radiation savings of 50%, 63% and 78% respectively). Overall image quality was similar with standard dose (1.9 ± 0.6) and low-dose (2.0 ± 0.5) compared to the non-tailored group (1.9 ± 0.5) (p = NS for all). In the ultra-low dose group however, image quality was significant reduced (2.7 ± 0.6), p < 0.05 versus all other groups).

Conclusion

Using BMI-adapted low dose acquisitions image quality can be maintained with simultaneous radiation savings of ∼65% (dose of ∼1 mSv). This appears to be the lower limit for diagnostic coronary CTA, whereas ultra-low dose acquisitions result in significant image degradation.  相似文献   

12.

Objective

To identify factors that might explain why a prostate with a Gleason score (GS) <7 in the biopsy specimen can turn out to have a GS ≥7 in the surgical specimen.

Material and methods

We compared the GS of biopsy specimens with the GS of surgical specimens in 185 patients who underwent surgery for prostate cancer. We calculated the sensitivity, specificity, and predictive values for the GS of the biopsy specimens. We used Cohen's kappa to determine the degree of concordance between a GS of <7 and ≥7 for the biopsy specimen and the surgical specimen. Age, a family history of prostate cancer, total prostate-specific antigen (tPSA), digital rectal examination, prostate structure and volume, and the number of biopsy cores (biopsy scheme) were analyzed using multivariable logistic regression.

Results

Histological study of biopsy specimens yielded high sensitivity (98%) but low specificity (49%) for GS ≤6 and low sensitivity (35, 26%) and high specificity (93, 99%) for GS=7 and GS ≥7, respectively. Cohen's kappa for the GS from the biopsy and surgical specimens was 0.43 (95% CI=30-56%). The biopsy scheme was the only predictor of discordance in the GS between the two techniques. Among the other variables included in the model, only tPSA showed a slightly significant association. Taking a scheme with less than 7 cores as a reference, we found no difference with 8 to 9 cores but we did find a difference with 10 to 11 cores and with 12 or more cores, with a prevalence ratio of 0.138 (95% CI=0.030-0.513) and 0.277 (95% CI=0.091-0.806), respectively.

Conclusion

The GS of the biopsy depends on the scheme. This factor must be taken into account when choosing a treatment option in patients with low tumor grade in biopsy specimens.  相似文献   

13.

Objective

To describe cases of obstetric hemorrhage that have called for selective intra-arterial embolization and the different embolization techniques used. To assess the clinical outcomes and postprocedural fertility.

Material and methods

We studied 27 women with obstetric hemorrhage. In 24 patients, embolization was performed by catheterizing both uterine arteries and in 2 patients only one uterine artery was catheterized (pseudoaneurysm). The materials used for embolization consisted of Spongostan in 17/27, particles in 9/27, and coils in 1/27. Clinical follow-up included an analysis of early and late complications and of postprocedural fertility.

Results

Hemorrhage was classified as primary (25/27) or secondary (2/27).The cause of bleeding was vaginal delivery (20), cesarean sections (5), abortion (1), and cervical ectopic pregnancy (1).The initial technical success rate was 100% and the clinical success rate was 92.6% (25 of the 27 patients).Bleeding ceased and the outcome was satisfactory in 25 patients. During clinical follow-up ranging from one to seven years, 23 patients had normal menstruation and 6 patients completed 7 full-term pregnancies.

Conclusion

Intra-arterial embolization for obstetric hemorrhage leads to good outcomes and few complications and it preserves fertility.  相似文献   

14.

Objective

To evaluate the effect of different acquisition parameters and reconstruction algorithms in lung lesions conspicuity in chest MDCT.

Methods

An anthropomorphic chest phantom containing 6 models of lung disease (ground glass opacity, bronchial polyp, solid nodule, ground glass nodule, emphysema and tree-in-bud) was scanned using 80, 100 and 120 kVp, with fixed mAs ranging from 10 to 110. The scans were reconstructed using filtered back projection (FBP) and iterative reconstruction (IR) algorithms. Three blinded thoracic radiologists reviewed the images and scored lesions conspicuity and overall image quality. Image noise and radiation dose parameters were recorded.

Results

All acquisitions with 120 kVp received a score of 3 (acceptable) or higher for overall image quality. There was no significant difference between IR and FBP within each setting for overall image quality (p > 0.05), even though image noise was significantly lower using IR (p < 0.0001). When comparing specific lower radiation acquisition parameters 100 kVp/10 mAs [Effective Dose (ED): 0.238 mSv] vs 120 kVp/10 mAs (ED: 0.406 mSv) vs 80 kVp/40 mAs (ED: 0.434 mSv), we observed significant difference in lesions conspicuity (p < 0.02), as well as significant difference in overall image quality, independent of the reconstruction algorithm (p < 0.02), with higher scores on the 120 kV/10 mAs setting. Tree-in-bud pattern, ground glass nodule and ground glass opacity required lower radiation doses to get a diagnostic score using IR when compared to FBP.

Conclusion

Designing protocols for specific lung pathologies using lower dose acquisition parameters is feasible, and by applying iterative reconstruction, radiologists may have better diagnostic confidence to evaluate some lesions in very low dose settings, preserving acceptable image quality.  相似文献   

15.

Introduction

The purpose of this study was to estimate total effective dose and cancer risk related to treatment monitoring and surveillance computed tomography (CT) scans in a cohort of patients diagnosed with lymphoma.

Methods

76 patients with head, neck, chest, abdomen or pelvis CT and whole-body positron emission tomography (PET)/CT were identified from an institutional lymphoma database; this included 54 (71%) patients with non-Hodgkin and 22 (29%) patients with classical Hodgkin lymphoma. Average treatment and surveillance periods were 8 months (range, 3–14 mo) and 23 months (range, 1–40 mo), respectively. Radiation exposure was estimated from the dose-length product (DLP) for CT scans and milli-Curies and DLP for PET/CT scans. Cancer risk was estimated using the Biological Effects of Ionizing Radiation model.

Results

During their treatment period, 45 patients had 161 CT exams and 39 patients had 73 PET/CT exams. Mean effective dose was 39.3 mSv (range, 7.1–100 mSv). During the surveillance period, 60 patients had 378 CT exams and 25 patients had 39 PET/CT exams. Mean effective dose was 53.2 mSv (range, 2.6–154 mSv). Seventeen of 76 (22.4%) patients had total cumulative doses greater than 100 mSv. The mean increase in estimated cancer risk was 0.40%; the greatest estimated risk to any one patient was 1.19%.

Conclusion

Mean total effective dose and mean estimated cancer risk were low in patients with lymphoma undergoing serial imaging, suggesting that theoretical risks of radiation-induced cancer need not be a major consideration in radiologic follow-up.  相似文献   

16.

Purpose

To determine effective dose (E) during standard chest CT using an organ dose-based and a dose-length-product-based (DLP) approach for four different scan protocols including high-pitch and dual-energy in a dual-source CT scanner of the second generation.

Materials and methods

Organ doses were measured with thermo luminescence dosimeters (TLD) in an anthropomorphic male adult phantom. Further, DLP-based dose estimates were performed by using the standard 0.014 mSv/mGycm conversion coefficient k. Examinations were performed on a dual-source CT system (Somatom Definition Flash, Siemens). Four scan protocols were investigated: (1) single-source 120 kV, (2) single-source 100 kV, (3) high-pitch 120 kV, and (4) dual-energy with 100/Sn140 kV with equivalent CTDIvol and no automated tube current modulation. E was then determined following recommendations of ICRP publication 103 and 60 and specific k values were derived.

Results

DLP-based estimates differed by 4.5–16.56% and 5.2–15.8% relatively to ICRP 60 and 103, respectively. The derived k factors calculated from TLD measurements were 0.0148, 0.015, 0.0166, and 0.0148 for protocol 1, 2, 3 and 4, respectively. Effective dose estimations by ICRP 103 and 60 for single-energy and dual-energy protocols show a difference of less than 0.04 mSv.

Conclusion

Estimates of E based on DLP work equally well for single-energy, high-pitch and dual-energy CT examinations. The tube potential definitely affects effective dose in a substantial way. Effective dose estimations by ICRP 103 and 60 for both single-energy and dual-energy examinations differ not more than 0.04 mSv.  相似文献   

17.

Objective

Two macrocyclic extracellular contrast agents, one-molar neutral gadobutrol and ionic gadoterate meglumine, were compared to determine the overall preference for one or the other in a clinical setting.

Materials and methods

Multicenter, randomized, single-blind, intra-individually controlled, comparison study with a corresponding blinded read. Efficacy analysis was based on 136 patients who underwent identical MRI examinations: group A first received 1.0 M gadobutrol followed by 0.5 M gadoterate meglumine 48 h to 7 days later; group B had a reversed administration order. Three independent blinded readers assessed off-site their overall diagnostic preference (primary efficacy parameter) based on a matched pairs approach.

Results

Superiority of gadobutrol over gadoterate meglumine was demonstrated for the qualitative assessment of overall preference across all readers by a statistically significant difference between both contrast agents for this primary endpoint. Preferences in lesion enhancement (secondary endpoint) were also found significantly in favor of gadobutrol. For preference in lesion delineation from surrounding tissue/edema and for internal structure only a trend towards a higher proportion for gadobutrol was found (except for internal structure reported by one reader, which showed a result of statistical significance). Lesion contrast and relative lesion enhancement (quantitative parameters) were statistically significantly higher for gadobutrol compared to gadoterate meglumine.

Conclusion

Contrast-enhanced MRI of neoplastic brain lesions at a dose of 0.1 mmol Gd/kg body weight, assessed in a standardized off-site blinded reading, results in a significantly higher qualitative and quantitative preference for gadobutrol compared to gadoterate meglumine.  相似文献   

18.

Purpose

To investigate the quantitative and qualitative differences between combined positron emission tomography and computed X-ray tomography (PET/CT) enhanced with contrast medium with either an iodine concentration 300 mg/ml or 370 mg/ml.

Materials and methods

120 consecutive patients scheduled for F-18-Fluorodeoxyglucose (FDG) PET/CT were included. The first (second) 60 patients received contrast medium with 300 (370) mg iodine/ml. Intravenous injection protocols were adapted for an identical iodine delivery rate (1.3 mg/s) and body surface area (BSA) adapted iodine dose (22.26 g I/m2). Maximum and mean standardized uptake values (SUVmax; SUVmean) and contrast enhancement (HU) were determined in the ascending aorta, the abdominal aorta, the inferior vena cava, the portal vein, the liver and the right kidney in the venous contrast medium phase. PET data were evaluated visually for the presence of malignancy and image quality.

Results

Both media caused significantly higher values for HU, SUVmean and SUVmax for the enhanced PET/CT than the non-enhanced one (all p < 0.01). There were no significant differences in the degree of increase of HU, SUVmean and SUVmax between the two contrast media at any anatomic site (all p > 0.05). Visual evaluation of lesions showed no differences between contrast and non-contrast PET/CT or between the two different contrast media (p = 0.77).

Conclusion

When using a constant iodine delivery rate and total iodine dose in a BSA adapted injection protocol, there are no quantitative or qualitative differences in either CT or PET between contrast media with an iodine concentration of 300 mg/ml and 370 mg/ml, respectively.  相似文献   

19.

Purpose

To assess lesion detection and diagnostic image quality of filtered back projection (FBP) reconstruction technique in ultra low-dose chest CT examinations.

Methods and materials

In this IRB-approved ongoing prospective clinical study, 116 CT-image-series at four different radiation-doses were performed for 29 patients (age, 57–87 years; F:M – 15:12; BMI 16–32 kg/m2). All patients provided written-informed-consent for the acquisitions of additional ultra low-dose (ULD) series on a 256-slice MDCT (iCT, Philips Healthcare). In-addition to their clinical standard-dose chest CT (SD, 120 kV mean CTDIvol, 6 ± 1 mGy), ULD-CT was subsequently performed at three-dose-levels (0.9 mGy [120 kV]; 0.5 mGy [100 kV] and 0.2 mGy [80 kV]). Images were reconstructed with FBP (2.5 mm * 1.25 mm) resulting into four-stacks: SD-FBP (reference-standard), FBP0.9, FBP0.5, and FBP0.2. Four thoracic-radiologists from two-teaching-hospitals independently-evaluated data for lesion-detection and visibility-of-small-structures. Friedman's-non-parametric-test with post hoc Dunn's-test was used for data-analysis.

Results

Interobserver-agreement was substantial between radiologists (k = 0.6–0.8). With pooled analysis, 146-pulmonary (27-groundglass-opacities, 64-solid-lung-nodules, 7-consolidations, 27-emphysema) and 347-mediastinal/soft tissue lesions (87-mediastinal, 46-hilar, 62-axillary-lymph-nodes, and 11-mediastinal-masses) were evaluated. Compared to the SD-FBP, 100% pulmonary-lesions were seen with FBP0.9, up to 81% with FBP0.5 (missed: 4), and up to 30% with FBP0.2 images (missed:16). Compared to SD-FBP, all enlarged mediastinal-lymph-nodes were seen with FBP0.9 images. All mediastinal-masses (>2 cm, 11/11) were seen equivalent to SD-FBP images at 0.9 mGy. Across all sizes of patients, FBP0.9 images had optimal visualization for lung findings. They were optimal for mediastinal soft tissues for only non-obese patients.

Conclusion

Filtered-back-projection technique allows optimal lesion detection and acceptable image quality for chest-CT examinations at CDTIvol of 0.9 mGy for lung and mediastinal findings in selected sizes of patients.  相似文献   

20.
Gao Y  Lu B  Hou Z  Yu F  Cao H  Han L  Wu R 《European journal of radiology》2012,81(7):e789-e795

Objectives

To investigate the radiation dose and image quality of prospective ECG-triggering dual-source CT angiography in infants with complex congenital heart disease (CHD) in comparison with retrospective ECG-gated scanning.

Methods

Ninety-six infants less than 1 year old (60/36 male/female, age: 4.8 ± 2.7 months, weight: 5.8 ± 1.8 kg) with complex CHD were enrolled. Three image acquisition protocols were set: group 1: 80 kV, 100 mA, retrospective ECG-gated protocol; group 2: 80 kV, 100 mA, prospective ECG-triggering protocol with acquisition window of 380 ms; group 3: 80 kV, 100 mA, prospective ECG-triggering protocol with acquisition window of 200 ms. Patients were selected to any one of the protocols randomly. The signal-to-noise ratios (SNR) were calculated in the ascending aorta and the pulmonary artery trunk. Image quality was assessed by a five-point score. A score of <3 represents non-diagnostic. Effective radiation dose (ED) was calculated.

Results

Image quality score of groups 1, 2 and 3 were 4.1 ± 0.4, 4.0 ± 0.6 and 4.2 ± 0.6 (p = 0.224). SNR of ascending aorta and pulmonary artery trunk among them had no statistical difference (all p > 0.05). The average ED (median) of groups 1, 2 and 3 were 1.17 ± 0.07 mSv (1.25 mSv), 0.72 ± 0.24 mSv (0.78 mSv) and 0.48 ± 0.41 mSv (0.39 mSv). Any two of the three groups had significant differences (all p < 0.001).

Conclusion

Prospective ECG-triggering DSCT angiography associated with a significantly lower ED than retrospective protocol, while maintaining image quality for diagnosis. Prospective ECG-triggering DSCT angiography could be used as a very important second-line diagnostic tool in infants with complex CHD.  相似文献   