共查询到18条相似文献,搜索用时 201 毫秒
1.
室内空气中甲醛的固相吸附气体采样管研制和性能评价 总被引:7,自引:0,他引:7
目的研制一种用于室内空气中甲醛采样测定的固相吸附气体采样管。方法固相吸附气体采样管由两端套有硅橡胶塞的玻璃管和管内带有甲醛吸收液的表面改性的合成纤维丝束组成。建立用该采样管对室内空气中甲醛采样和测定方法,并评价其性能。结果固相吸附气体采样管采样效率、洗脱效率分别为(98.73±0.86)%和(98.60±1.20)%;采样精密度RSD=4.02%(n=10)。该法与国标气泡吸收管法(GBT161291995)的测定结果经t检验,两种方法无显著性差异。结论研制的固相吸附气体采样管可用于室内空气中甲醛的采样测定。 相似文献
2.
目的研制一种适合于大批量室内和环境空气中二氧化氮气体(NO2)现场采样的固相气体采样管。方法固相NO2气体采样管由两端套有硅胶塞玻璃管及其内部填充经过改性的聚丙烯纤维丝束并涂布NO2吸收液,作为固相填充物的载体而组成。建立固相NO2气体采样管对NO2的采样方法。采用改进的Saltzman法(国标法)评价其性能。结果固相NO2气体采样管法的洗脱效率和采集效率≥(99.68±5.45)%和(97.29±0.83)%;该法测定低(0.11mg/m3)、中(0.46mg/m3)、高3(0.85mg/m3)3种不同质量浓度的NO2气体并与国标法比较,两者测定结果分别相差9.10%、4.35%和3.53%,2种方法测定结果差异无显著性(P〉0.05)。结论研制的固相NO2气体采样管可用于大规模环境和室内空气中N0’的现场采样。 相似文献
3.
目的 研制一种适合大批量环境和室内空气中SO2,现场采样的固相气体采样管.方法 固相二氧化硫采样管由两端套有硅胶塞的玻璃管及其内部填充涂布SO2吸收液的聚丙烯纤维丝束作为固相填充物的载体而组成;建立固相二氧化硫采样管对SO2的采样方法;采用甲醛溶液吸收-盐酸副玫瑰苯胺分光光度法评价其性能.结果 固相二氧化硫采样管法的采... 相似文献
4.
目的研制一种适合大批量室内和环境空气中氨气(NH3)现场采样的固相气体采样管,以适应现场采样的需要。方法固相氨气采样管由两端套有硅胶塞玻璃管及其内部填充经过改性的聚丙烯纤维丝束并涂布NH3吸收液,作为固相填充物的载体而组成。建立固相氨气采样管对NH3的采样方法。采用靛酚蓝分光光度法(国标法)评价其性能。结果固相氨气采样管法的洗脱效率和采集效率为≥(96.50±1.73)%和(96.30±0.61)%;用建立的方法测定(0.13±0.01)mg/m3、(0.49±0.03)mg/m3、(0.86±0.05)mg/m33种水平的NH3,并与国标法比较,两者测定结果分别相差了7.69%、4.08%和6.98%。结论研制的固相氨气采样管采样效率较高,测量结果准确,为环境和室内空气中进行大批量NH3的现场采样提供了一种新的方法。 相似文献
5.
目的研制一种适合大批量室内和环境空气中甲醛现场采样的气体采样管。方法甲醛采样管是由内径5 mm,长度20 cm玻璃管,其两端套有硅胶塞而组成,内部填充经处理后的聚丙烯纤维丝束并涂布甲醛吸收液。建立甲醛采样管对甲醛的采样及其检测方法,采用AHMT(4-氨基-3-联氨-5-巯基-1,2,4-三氮杂茂)分光光度法评价其性能。结果甲醛采样管对甲醛的采集效率≥95.19%,洗脱效率为105.19%~107.44%,采用甲醛采样管作为甲醛气体的检测方法与国标法(AHMT法)对(0.37±0.20)mg/m3、(1.30±0.20)mg/m3、(2.31±0.25)mg/m33个浓度甲醛气体检测结果进行比较,分别相差(8.03±4.97)%、(7.41±3.50)%和(5.20±3.21)%。结论研制的甲醛采样管用于甲醛气体的检测具有采样效率高、测量结果准确等优点,适用于环境和室内空气中大批量甲醛的现场采样工作,并为现场采样提供了一种新方法。 相似文献
6.
吴娟 《中国卫生检验杂志》2005,15(8):1023-1024
本文从原理、应用和优缺点方面阐述了室内有害气体的浓缩预处理方法。包括固相萃取-溶剂解析(热解吸)法、固相微萃取法、衍生化反应浓缩处理法、溶剂浓缩预处理法及冷冻浓缩-热解吸法。根据被检测物质的性质来确定浓缩预处理方法。 相似文献
7.
柳于氨醇又名舒喘灵(salbutamol简称SALB)用于动物可以减少脂肪组织,增加瘦肉和促进生长。肉中柳于氨醇残留量的分析方法,有酶免疫测定法、GG/MS法、HPLC法和FL—HPLC法。用FL—HPLC分析,样品的前处理采用免疫亲的色谱法(immuno 相似文献
8.
9.
空气中的氨具有刺激性,损害人的身体健康,建立灵敏度高、特异性好、简便环保的检测氨的方法是十分必要的。该文介绍了空气中氨检测技术的研究进展,主要包括靛粉蓝、纳氏试剂比色法、乙酰丙酮甲醛分光光度法、水杨酸盐分光光度法、茚三酮光度法等比色法和离子色谱法。并对氨测定过程的不确定度进行了分析,同时介绍了一种新研制的用于室内空气中氨采样测定的固体吸附采样管。 相似文献
10.
〔目的〕建立一个适用于污水中脊髓灰质炎病毒分离培养的方法。〔方法〕采用固相化的L2 0B细胞吸附法 ,浓集污水中的脊髓灰质炎病毒 ,将浓集物再用活的L2 0B细胞培养。〔结果〕能够检出 10 0 0ml水中的 0 .1~ 10TCID50 量的脊髓灰质炎病毒 ,在10 0 0ml预处理后的污水中加入 10TCID50 量的病毒 ,亦可以检出。〔结论〕本方法的有效检出限为 10TCID50 / 10 0 0ml,可用于污水中的脊髓灰质炎病毒的浓集和分离培养。 相似文献
11.
12.
便携式气相色谱仪测定室内空气中低浓度苯系物及其同系物的方法研究 总被引:2,自引:0,他引:2
目的建立便携式色谱仪快速测定室内空气中低浓度苯系物的方法。方法在Tedlar气袋中制备目标化合物单标样品,采用便携式色谱仪内置恒流泵采样,预浓缩器预浓缩后热解析进样,毛细管柱分离,微氩离子检测器检测,确定保留时间,保留时间定性;采用液体外标法制备不同浓度的目标化合物混合标准,峰面积定量。结果在本研究所选择的色谱条件下,对苯系物具有良好的分离效果,分析周期为15min;检测浓度范围分别为苯0.018~0.879mg/m3、甲苯0.035~1.299mg/m3、乙苯0.035~1.300mg/m3、间(对)二甲苯0.035~1.320mg/m3、邻二甲苯0.035~1.296mg/m3。对苯、甲苯、乙苯、间二甲苯、邻二甲苯的最低检出浓度分别为7.5、11.5、28.8、30.3和30.6μg/m3;实验室内测定和现场测定结果与标准方法比较相对偏差分别小于13.9%和20.0%。在不同浓度下同一天和一周内进行的方法精密度实验相对标准偏差小于8.4%。结论该方法灵敏度高、重现性好,抗干扰能力强,具有较高的准确度,可以满足室内空气中低浓度苯系物快速测定的要求。 相似文献
13.
[目的]探讨儿童哮喘IgE、IgA、IgG、IgM、C3、C4、外周血嗜酸性细胞与室内装修关系及室内甲醛、苯、氨浓度与儿童哮喘关系. [方法]在哮喘儿童中房屋装修30例,对照组非房屋装修30例,于入院时抽血检测IgE,IgAIgG,IgM,C3,C4外周血嗜酸性细胞进行对照研究.在室内装修(小于5年)中哮喘儿童61例,对照组非哮喘儿童61例,测量室内甲醛、苯、氨浓度进行对照研究.[结果]装修组30例哮喘儿童IgE,IgA,外周血嗜酸性细胞明显高于对照组,差异有统计学意义(P<0.05).IgG,IgM,C3,C4,差异无统计学意义(P>0.05).哮喘儿童室内甲醛、苯、氨浓度与对照组差异有统计学意义(P<0.05).非参数相关分析甲醛、苯和氨与儿童哮喘呈正相关性.[结论]室内装修导致室内空气不良可诱发儿童哮喘并加重哮喘.装饰材料中主要污染物-甲醛、苯、氨对哮喘儿童健康危害较大,应加强该方面的调查研究加快装饰材料立法和标准的制定. 相似文献
14.
Since the past decade, there is growing concern on the health implications of fungal exposure in indoor environments. Several methods are available for the measurement of airborne viable fungi, however, there is still a lack of standardization and comparability of these methods. The purpose of our field study was to apply the recommendations of the newly released technical standards TRBA 405 and 430 to the conditions of non-industrial indoor environments and to investigate the comparative performance of the two recommended filter cassette samplers (Sartorius MD8 and GSP) using the direct method. During two sampling phases (August to beginning of December 2000, and December 2000 to February 2001) a total of 360 short-term samples and 30 long-term samples were analyzed in parallel at 20 sampling days. Mean fungal CFUs varied from 2×101 to 3×102 CFU/m3, with the relative recovery of the GSP (vs. MD8) method being 1.00 (range, 0.89 – 1.14). We found a good correlation (Pearson's r=0.95) between the MD8 and the GSP method. Both samplers showed good reproducibility, the coefficients of variation being 19.4% for the MD8, and 13.2% for the GSP sampler. Aspergillus and Penicillium (median proportions >20% of the fungal CFUs, each) were the most prevalent indoor fungal genera during this season, followed by Wallemia (>10%) and Cladosporium. The coefficients of variation for single genera ranged from 27% to 89%. We conclude that the recommendations of the technical standards TRBA 405 and 430 can efficiently be applied to survey fungal exposure under the conditions of non-industrial indoor environments. If short-term samples by using the MD8 are conducted for orientating purposes, at least two to three samples per sampling site are necessary in order to minimize intra-sampler variability (r>0.95). Due to easy overloading of the small filter surface of the GSP at higher airborne spore concentrations, the more representative long-term sampling should preferably be done by using the indirect method, however, the results of both methods may not be equated. The interpretation of the fungal spectrum should be conducted with caution, particularly at low absolute concentrations. 相似文献
15.
顶空固相微萃取气相色谱法测定饮水中氯酚 总被引:3,自引:0,他引:3
目的建立顶空固相微萃取(HSSPME)气相色谱法测定水中氯酚(CPs)的方法。方法采用SPME前处理技术,用毛细色谱柱分离,电子捕获检测器检测。结果2氯酚(MCP),2,4二氯酚(DCP),2,4,6三氯酚(TCP),五氯酚(PCP)的最低检出浓度分别为60.0、2.64、0.15和0.84μgL;标准曲线的相关系数分别为0.999、0.997、0.997、0.995;样品低、中、高三种浓度的加标后回收率分别为95.3%~107%、93.6%~102%、92.4%~102%、91.5%~99.1%;相对标准偏差(n=6)分别为1.0%~8.1%、1.6%~6.6%、2.9%~8.6%、2.0%~8.2%。结论该法简便、灵敏,不使用有机溶剂,是测定氯酚类化合物的理想方法。 相似文献
16.
扩散法被动式挥发性有机化合物个体监测器的研制 总被引:4,自引:0,他引:4
研制了一种以单层活性炭颗粒作为吸收介质的被动式挥发性有机化合物个体监测器。空气中挥发性有机化合物依据分子扩散原理传质到采样器中,并吸附到活性炭上。采样后,取出活性炭吸附层,用二硫化碳洗脱,再用气相色谱法定性和定量。对监测器进行了实验室性能评价和现场验证。结果表明,采样器在风速20~150cm/s,相对温度10%~80%,温度-10~35℃范围内使用,采样速率分别为60ml/min(苯)、54ml/min(甲苯)、54ml/min(氯仿)和49ml/min(对-二甲苯),相对标准差小于5%。在现场与有泵活性炭管采样相比较,本个体监测器测定空气中挥发性有机化合物的总不确定度分别为12%(苯)、12%(甲苯)、26%(对-二甲苯)和16%(氯仿),可适用于室内空气污染和个体接触量的监测。 相似文献
17.
中国部分城市住宅室内空气中重要污染物的调查研究 总被引:7,自引:1,他引:7
目的调查中国部分城市住宅室内空气中总挥发性有机化合物、苯、甲苯、二甲苯、甲醛、氨和氡的污染状况。方法在每个城市中随机选择装修完成时间一年之内的住宅作为监测对象,测定室内空气中甲醛、氨、苯系物、总挥发性有机化合物和氡的浓度,在入户监测的同时,进行住宅室内状况调查。调查时间为2002年5月至2004年11月。采样点高度保持在呼吸带,采样时间为30分钟。甲醛、氨、苯系物和总挥发性有机化合物分别采用AHMT分光光度法、纳氏试剂比色法和TenaxTA吸附/二次热解吸/毛细管气相色谱法,氡的测量采用α径迹探测器法。结果甲醛、氨、总挥发性有机化合物的平均浓度分别为(0.16±0.16)、(0.12±0.15)、(2.18±12.94)mg/m3;苯系物(苯、甲苯、二甲苯)的平均浓度分别为(124.04±272.60)、(258.90±672.98)、(189.68±561.16)μg/m3;氡浓度算数平均值和几何平均值分别为(43.8±37.7)和37.4Bqm-3。结论住宅室内装修污染的主要污染物为甲醛、苯系物、TVOC。26个主要城市室内氡浓度的监测结果可基本反应出我国室内氡的水平、超标比率、变化趋势。 相似文献