首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
Subdural hematomas (SDHs) comprise a significant percentage of missed intracranial hemorrhage on axial brain CT. SDH detection rates could be improved with the addition of reformatted images. Though performed at some centers, the potential additional diagnostic sensitivity of reformatted images has not yet been investigated. The purpose of our study is to determine if the addition of coronal and sagittal reformatted images to an axial brain CT increases the sensitivity and specificity for detection of acute traumatic SDH. We retrospectively reviewed consecutive brain CTs acquired for acute trauma that contained new SDHs. An equivalent number of normal brain CTs served as control. Paired sets of images were created for each case: (1) axial images only (“axial only”) and (2) axial, coronal, sagittal images (“reformat added”). Three readers interpreted both the axial only and companion reformat added for each case, separated by 1 month. Reading times and SDH detection rates were compared. One hundred SDH and 100 negative examinations were collected. Sensitivity and specificity for the axial-only scans were 75.7 and 94.3 %, respectively, compared with 88.3 and 98.3 % for reformat added. There was a 24.3 % false negative (missed SDH) rate with axial-only scans versus 11.7 % with reformat added (p = <0.001). Median reader interpretation times were longer with the addition of reformatted images (125 versus 89 s), but this difference was not significant (p = 0.23). The addition of coronal and sagittal images in trauma brain CT resulted in improved sensitivity and specificity as well as a reduction in SDH false negatives by greater than 50 %. Reformatted images substantially reduce the number of missed SDHs compared with axial images alone.  相似文献   

2.
Choi JY  Lee JM  Lee JY  Kim SH  Lee MW  Han JK  Choi BI 《European radiology》2007,17(12):3130-3138
To retrospectively assess the value of multiplanar reformations (MPRs) compared with standard axial images in the assessment of hilar and extrahepatic bile duct cancer. Forty-eight patients with confirmed bile duct cancer were included as preoperative work-ups; all of these patients underwent contrast-enhanced multidetector CT consisting of axial and MPR images. Two radiologists independently assessed the axial images alone and the combined axial and MPR images in the coronal and sagittal planes for the presence of tumor, its extent, vascular involvement, and resectability. The results were compared with surgical and pathologic findings. For tumor presence and conspicuity, combined axial and MPR images had higher values than the axial only images. For evaluation of tumoral extent, there was no difference between the two image sets for either reader. The accuracy for tumor extent was lower in hilar cancer than in extrahepatic bile duct cancer. For evaluation of vascular involvement and resectability, the area under the receiver operating characteristic curve of axial images was not significantly different from that of the reformatted images.The addition of MPR images to the standard axial images did not significantly improve the diagnostic performance of MDCT in the evaluation of the bile duct cancer.  相似文献   

3.
To assess the value of three-dimensional (3D) image reconstructions of two-dimensional (2D) data from contiguous non-overlapping slices in the diagnosis of spinal trauma, 21 patients with a total of 36 injured vertebrae and 4 normal controls were examined. Forty plain films in two planes, 40 axial CT scans with multiplanar reformatted (MPR) 2D reconstructions and 40 sets of 3D images (surface rendering technique) were independently evaluated by four readers. The final diagnosis was defined after a panel review of clinical, surgical and imaging findings on all modalities. The 3D image reconstructions were not as accurate as axial CT with MPR 2D reconstructions in the diagnosis of vertebral body (n = 20) and posterior element fractures (n = 35). Dislocation (n = 3) was equally well detected by all imaging modalities. Narrowing of the spinal canal (n = 17) was best assessed by either MPR 2D CT or 3D images. A rotational component was diagnosed more accurately by 3D images, followed by 2D CT and plain films. Thus, 3D images combined with MPR 2D CT reconstructions are an important adjunct for an accurate diagnosis of spinal trauma, especially when a rotational component is suspected.Presented at the 1993 ECR Scientific Assembly Correspondence to: C. H. Buitrago-Téllez  相似文献   

4.
PURPOSE: To evaluate if coronal reformatted images can be used for primary interpretation of MDCT of the abdomen and pelvis using 64-slice MDCT. MATERIALS AND METHODS: IRB approval was obtained. We reviewed MDCT studies of the abdomen and pelvis of 220 consecutive patients performed with 64 row MDCT with constant scanning parameters. Based on a 0.625mm raw data set, transverse images were reconstructed at 5mm and coronal images at 3mm using standard reconstruction algorithms. Reader familiarity was achieved by simultaneous evaluation of transverse and coronal reformats in an initial group of 20 separate cases for findings in consensus. Two subsequent phases of image analysis were then performed in two groups of 100 patients each. In the first phase two radiologists evaluated the added utility of simultaneous review of MDCT of transverse and coronal reformatted images over transverse images alone in 100 consecutive patients referred for MDCT of the abdomen and pelvis. In the second phase, the same radiologists evaluated whether coronal multiplanar reformats could be used for primary interpretation of MDCT of the abdomen and pelvis in a separate but similar cohort of 100 consecutive abdominopelvic MDCT studies. The number of lesion(s), their location, size of smallest lesion, presence of artifacts and likely diagnosis were noted at each image interpretation. Image quality and confidence for interpretation was evaluated using five-point and three-point scale, respectively. The time required for primary interpretation of coronal reformats and transverse images were recorded. Statistical analysis was performed using Wilcoxon signed rank test. RESULTS: Both readers detected additional findings (n=37, 35), respectively, on simultaneous review of transverse and coronal reformats as compared with transverse images alone (p<0.001). Excellent interobserver agreement was noted (r=0.94-0.96). Both readers detected additional findings (n=62, 53), respectively, on independent review of coronal reformats as compared with transverse images alone (p<0.001). Readers' confidence was also found to be higher on coronal evaluations as compared to axial images (p<0.01). There was good interobserver agreement between the two readers. CONCLUSION: Independent coronal multiplanar reformatted images obtained using state-of-the-art MDCT scanners show promise as the preferred orientation and can be useful for primary interpretation of MDCT of the abdomen and pelvis.  相似文献   

5.
PurposeTo evaluate if coronal reformatted images can be used for primary interpretation of MDCT of the abdomen and pelvis using 64-slice MDCT.Materials and methodsIRB approval was obtained. We reviewed MDCT studies of the abdomen and pelvis of 220 consecutive patients performed with 64 row MDCT with constant scanning parameters. Based on a 0.625 mm raw data set, transverse images were reconstructed at 5 mm and coronal images at 3 mm using standard reconstruction algorithms. Reader familiarity was achieved by simultaneous evaluation of transverse and coronal reformats in an initial group of 20 separate cases for findings in consensus. Two subsequent phases of image analysis were then performed in two groups of 100 patients each. In the first phase two radiologists evaluated the added utility of simultaneous review of MDCT of transverse and coronal reformatted images over transverse images alone in 100 consecutive patients referred for MDCT of the abdomen and pelvis. In the second phase, the same radiologists evaluated whether coronal multiplanar reformats could be used for primary interpretation of MDCT of the abdomen and pelvis in a separate but similar cohort of 100 consecutive abdominopelvic MDCT studies. The number of lesion(s), their location, size of smallest lesion, presence of artifacts and likely diagnosis were noted at each image interpretation. Image quality and confidence for interpretation was evaluated using five-point and three-point scale, respectively. The time required for primary interpretation of coronal reformats and transverse images were recorded. Statistical analysis was performed using Wilcoxon signed rank test.ResultsBoth readers detected additional findings (n = 37, 35), respectively, on simultaneous review of transverse and coronal reformats as compared with transverse images alone (p < 0.001). Excellent interobserver agreement was noted (r = 0.94–0.96). Both readers detected additional findings (n = 62, 53), respectively, on independent review of coronal reformats as compared with transverse images alone (p < 0.001). Readers’ confidence was also found to be higher on coronal evaluations as compared to axial images (p < 0.01). There was good interobserver agreement between the two readers.ConclusionIndependent coronal multiplanar reformatted images obtained using state-of-the-art MDCT scanners show promise as the preferred orientation and can be useful for primary interpretation of MDCT of the abdomen and pelvis.  相似文献   

6.
PURPOSE: To compare dynamic-contrast enhanced multirow detector computed tomography (MDCT) including multiplanar reformatted images (MPR) and magnetic resonance imaging (MRI) including magnetic resonance cholangiopancreatography images for the detection and assessment of locoregional extension of pancreatic adenocarcinoma. MATERIALS AND METHODS: Twenty-four patients with and 21 patients without pancreatic adenocarcinoma underwent triple-phase MDCT and MRI. Three radiologists independently attempted to detect pancreatic adenocarcinoma and assess locoregional extension in 3 sessions. First session involved MDCT images. In the second session, radiologists had access to coronal and sagittal MPR images together with the axial images (MDCT + MPR). Third session involved MR images. Results were compared with surgical findings using receiver operating characteristic analysis and kappa statistics. RESULTS: Regarding tumor detection, MDCT + MPR had a significantly higher value for areas under the curve (0.96 +/- 0.02) at receiver operating characteristic analysis compared with those of MRI (0.90 +/- 0.03) and MDCT (0.85 +/- 0.04). MDCT + MPR had the highest mean sensitivity (96%), and MRI had the highest mean specificity (98%). For locoregional extension, MDCT + MPR showed the highest kappa values of the study for all factors evaluated (range, 0.63-0.86). CONCLUSIONS: In conclusion, multiphasic MDCT imaging with MPR images was superior to multiphasic MDCT imaging without MPR images and to comprehensive MRI employing 2-D sequences and magnetic resonance cholangiopancreatography for both the detection and assessment of locoregional extension of pancreatic adenocarcinomas. MRI might be used for further lesion characterization regarding its high specificity.  相似文献   

7.
AIM: Although magnetic resonance (MR) imaging is widely used for rectal cancer staging, many centres in the UK perform computed tomography (CT) for staging rectal cancer at present. Furthermore in a small proportion of cases contraindications to MR imaging may lead to staging using CT. The purpose of this study was to evaluate the accuracy of current generation multidetector row CT (MDCT) in local staging of rectal cancer. In particular the accuracy of multiplanar (MPR) versus axial images in the staging of rectal cancer was assessed. MATERIAL AND METHODS: Sixty-nine consecutive patients were identified who had undergone staging of rectal cancer on CT. The imaging data were reviewed as axial images and then as MPR images (coronal and sagittal) perpendicular and parallel to the tumour axis. CT staging on axial and MPR images was then compared to histopathological staging. RESULTS: MPR images detected more T4 and T3 stage tumours than axial images alone. The overall accuracy of T-staging on MPR images was 87.1% versus 73.0% for axial images alone. The overall accuracy of N staging on MPR versus axial images was 84.8% versus 70.7%. There was a statistically significant difference in the staging of T3 tumours between MPR and axial images (p<0.001). CONCLUSION: Multidetector row CT has high accuracy for local staging of rectal cancer. Addition of MPR images to standard axial images provides higher accuracy rates for T and N staging of rectal cancer than axial images alone.  相似文献   

8.

Aim

To evaluate the diagnostic utility of multidetector computed tomography (MDCT) (axial, multiplanar reformatted images and virtual bronchoscopy) in preoperative assessment of post-traumatic tracheal stenosis.

Materials and methods

Twenty-four patients with post-traumatic tracheal stenosis underwent tracheal resection anastomosis. The diagnosis was ascertained on the basis of history and rigid-bronchoscopy. All patients were preoperatively evaluated by MDCT. Intraoperative findings were used as the gold standard. Lesions were evaluated in terms of site, distance from the vocal cords, length, grade of the stenosis and length of the planned resected segment.

Results

The sensitivity of MDCT was 100%, 100%, 92.3%, 92.3%, 96% and its accuracy was, 100%, 100%, 96%, 96%, 88.8% in assessment of tracheal stenotic site, distance from the vocal cords, length, length of segment planned for resection and stenotic grade, respectively. MPR (coronal and sagittal reformatted) images were 100% sensitive in detecting stenotic site and distance from the vocal cord. It showed 92.3% sensitivity and 96% accuracy in assessment of the stenotic segment length and the length of segment planned for resection. VB showed 96% sensitivity and 88.8% accuracy.

Conclusion

MDCT with its various display modes improved the preoperative evaluation of post-traumatic tracheal stenosis. The combined interpretation of axial, multiplanar reformatted and VE leads to improved diagnostic confidence. We recommend it as a constant demand for preoperative evaluation of post-traumatic tracheal stenosis.  相似文献   

9.
We sought to analyze retrospectively the advantages of coronal and sagittal reformations obtained with multidetector row computed tomography (CT) in patients with acute head trauma. Multidetector 16-section CT was performed in 200 patients (110 male and 90 female; age range, 3–87 years; mean age, 45 years) with acute head trauma. Scans were performed sequentially, and axial 5-mm-thick slices were obtained from base of skull to vertex. The source data set was reformatted in coronal and sagittal planes, with 2-mm-thick sections at 2-mm intervals. Images were analyzed retrospectively by two independent, blinded readers. The final diagnosis was determined by clinical follow-up. CT imaging abnormalities were detected in 55 out of 200 patients who were scanned for head trauma. Acute traumatic intracranial abnormality was detected on axial scans in 45 patients. Subtle findings were confirmed on coronal and sagittal CT reformations in ten cases, and these were undetected initially on axial CT. Coronal and sagittal reformations confirmed subtle findings in 18.2% (10/55) of the cases (P = 0.001). Indeterminate neuroimaging findings confirmed by coronal and sagittal CT head reformations include tentorial and interhemispheric fissure subdural hemorrhage, subarachnoid hemorrhage, and inferior frontal and temporal lobe contusions. Coronal and sagittal CT head reformations improve the sensitivity and diagnostic confidence in the clinical setting of acute trauma. Overall, coronal and sagittal reformations improved diagnostic confidence and interobserver agreement over axial images alone for visualization of normal structures and in the diagnosis of acute abnormality.  相似文献   

10.
PURPOSE: To determine the added value of multidetector computed tomography (MDCT)-assisted virtual bronchoscopy (VB) to axial MDCT and multiplanar reformatted (MPR) imaging with respect to conventional bronchoscopy in the evaluation of children with suspected foreign-body aspiration (FBA). MATERIAL AND METHODS: Twenty-one consecutive children (14 male, seven female, age 8 months-7 years, mean age 3.5 years) presenting with the suspicion of FBA were examined with 16-slice MDCT using 100-120 kV, 30-50 mA, 1-mm section thickness, 1.2 pitch ratio, and 0.6-1.0-mm reconstruction interval. Before CT examinations, chest radiographies were also obtained in all cases. VB and MPR imaging were carried out after MDCT examinations. RESULTS: Nine foreign bodies were identified by gold-standard conventional bronchoscopy. VB, thin-section axial MDCT, and MPR images identified eight of nine foreign bodies. CT scans with MPR images and VB did not reveal a chronic foreign body; and, in one patient, endobronchial mucous was diagnosed as the foreign body. The sensitivity, specificity, and accuracy of thin-section axial MDCT and MPR images alone in the diagnosis of FBA were 88.9%, 91.7%, and 90.5%, respectively. Results were the same as those obtained when VB was also included. CONCLUSION: MDCT with VB and axial/MPR images provide equally valuable information in children with suspected foreign-body aspiration and prevent unnecessary conventional bronchoscopic examinations. However, VB increases total examination time and cost, and it does not provide additional information over MPR images in the evaluation of foreign-body aspiration.  相似文献   

11.
The aim of this study was to assess retrospectively the value of adding coronal reformation images to the identification of the normal appendix using 64-slice multidetector CT (MDCT). 200 consecutive healthy adults with no history of abdominal surgery underwent abdominal CT using 64-slice MDCT without oral contrast administration and were enrolled in the study. Two gastrointestinal radiologists first interpreted the axial images only; after a 2-week interval, they then interpreted both the axial and the coronal images while blinded to the first interpretation. The identification of the normal appendix was interpreted using a four-point scale: 1, not identified; 2, identified with low confidence; 3, probably identified; 4, definitely identified. Agreement between the readers was determined with the use of weighted kappa statistics. Differences in confidence ratings for identification of the appendix were determined with the Wilcoxon signed rank test. The agreement between the readers was higher when both axial and coronal images were reviewed (kappa = 0.85) than when only the axial scans images were reviewed (kappa = 0.43). The mean confidence scores for the identification of the normal appendix by the two readers were significantly higher when both the axial and coronal images were reviewed (mean, 3.81+/-0.498 and 3.83+/-0.485 for the two readers, respectively) than when only the axial images were reviewed (mean, 3.27+/-0.819 and 3.47+/-0.856, respectively) (all p<0.01). Therefore, adding coronal reformation images to 64-slice MDCT significantly improves inter-reader agreement and confidence in the identification of the normal appendix.  相似文献   

12.
The purpose of this study was to assess the usefulness of curved multiplanar reformatted (MPR) images obtained by multislice CT for the depiction of the main pancreatic duct (MPD) and detection of resectable pancreatic ductal adenocarcinoma. This study included 28 patients with pancreatic carcinoma (size range 12–40 mm) and 22 without. Curved MPR images with 0.5-mm continuous slices were generated along the long axis of the pancreas from pancreatic-phase images with a 0.5- or 1-mm slice thickness. Seven blinded readers independently interpreted three sets of images (axial images, curved MPR images, and both axial and curved MPR images) in scrolling mode. The depiction of the MPD and the diagnostic performance for the detection of carcinoma were statistically compared among these images. MPR images were significantly superior to axial images in depicting the MPD, and the use of both axial and MPR images resulted in further significant improvements. For the detection of carcinoma, MPR images were equivalent to axial images, and the diagnostic performance was significantly improved by the use of both axial and MPR images. High-resolution curved MPR images can improve the depiction of the MPD and the diagnostic performance for the detection of carcinoma compared with axial images alone.  相似文献   

13.
The object of this study was to evaluate the usefulness of high-resolution multiplanar reformatted (MPR) images obtained by multislice CT in demonstrating connection between pancreatic cystic lesions and the main pancreatic duct. The study included 27 lesions with connection to the main pancreatic duct and 12 lesions without. All but one of the former lesions were branch duct-type intraductal papillary mucinous tumors (IPMTs). Oblique and curved MPR images with 0.5 mm continuous slices were generated from pancreatic-phase axial images reconstructed with 0.5 mm or 1 mm thickness at 0.5 mm intervals over a 260 mm field of view. The diagnostic capabilities for demonstrating connection with the main pancreatic duct were compared among axial images, MPR images, and both axial and MPR images in combination using the Brier score. The diagnosis in MPR images for demonstrating connection was more certain than that in axial images (P<0.05). Compared with MPR images alone, the use of both axial and MPR images resulted in further improvements in diagnostic performance, although the difference was not statistically significant. The use of high-resolution MPR images significantly improves diagnostic performance for demonstrating connection between pancreatic cystic lesions and the main pancreatic duct, which is useful for the diagnosis of branch duct-type IPMT.  相似文献   

14.
AIM: To determine the usefulness of multidetector-row CT (MDCT) with multiplanar reformatted (MPR) images in the sagittal and coronal plane in diagnosing acute right hemidiaphragmatic rupture. MATERIALS AND METHODS: Twelve patients were identified who received chest and abdominal MDCT after major blunt trauma diagnosed with right diaphragmatic injury. Sagittal and coronal reformations were performed in all cases. The images were retrospectively reviewed by two experienced radiologists for signs of right diaphragm injury, such as direct diaphragm discontinuity, the "collar sign", the "dependent viscera sign", and intra-thoracic location of herniated abdominal contents. RESULTS: Of the 12 cases of right hemidiaphragm rupture, diaphragm discontinuity was seen in seven (58%) cases, the collar sign in five (42%), the dependent viscera sign in four (33%), and transdiaphragmatic herniation of the right colon and fat in another. Two variants of the collar sign were apparent on high-quality sagittal and coronal reformations. The first, termed the "hump sign", describes a rounded portion of liver herniating through the diaphragm forming a hump-shaped mass, and the second, termed the "band sign," is a linear lucency across the liver along the torn edges of the hemidiaphragm. The hump sign occurred in 10 (83%) patients and the band sign in four (33%). CONCLUSION: MDCT is very useful in the diagnosis of right hemidiaphragm injury caused by blunt trauma when sagittal and coronal reformatted images are obtained, and should allow more frequent preoperative diagnosis.  相似文献   

15.
Our objective was to evaluate the ability of multiplanar reformatted (MPR) images combined with 0.5-mm axial images to depict the pancreatic and intrapancreatic bile ducts and compare the results with those of 0.5-mm axial, 2-mm axial, and 6-mm axial images alone. Seventy-seven patients without obstruction of the main pancreatic ducts (MPD) underwent dual-phase helical scanning of the pancreas using multislice computed tomography (MSCT). The MPR images were generated from 0.5-mm-thick images. Visualization of the pancreatic and intrapancreatic bile ducts and their confluence was graded on a four-point scale by a consensus of two radiologists. The results for 0.5-mm axial images in early-phase CT, 2-mm axial images in early-phase CT, MPR images combined with 0.5-mm axial images in early-phase CT, and 6-mm axial images in late-phase CT were then compared. The relationships of the focal pancreatic lesions with the pancreatic ducts were analyzed. The MPR images combined with 0.5-mm axial images were significantly superior to the other three types of images for the visualization of the pancreatic and intrapancreatic bile ducts and their confluence (p<0.01). The depiction rate of the MPD using MPR images combined with 0.5-mm axial images was 94, 94, 95, and 75%, respectively in the head, neck, body, and tail of the pancreas. Accessory pancreatic ducts, intrapancreatic bile ducts, and duct confluence were depicted in 48, 99, and 92%, respectively. In comparison with evaluation based on axial images alone, the use of MPR images more clearly demonstrated the relationship between the lesions and the pancreatic ducts in 14 of 19 lesions. The MPR images combined with 0.5-mm axial images improve the CT depiction of the pancreatic and intrapancreatic bile ducts in comparison with 0.5-mm axial, 2-mm axial, and 6-mm axial images alone. Electronic Publication  相似文献   

16.

Purpose

To compare different methods measuring abdominal aortic aneurysm (AAA) maximal diameter (Dmax) and its progression on multidetector computed tomography (MDCT) scan.

Materials and Methods

Forty AAA patients with two MDCT scans acquired at different times (baseline and follow-up) were included. Three observers measured AAA diameters by seven different methods: on axial images (anteroposterior, transverse, maximal, and short-axis views) and on multiplanar reformation (MPR) images (coronal, sagittal, and orthogonal views). Diameter measurement and progression were compared over time for the seven methods. Reproducibility of measurement methods was assessed by intraclass correlation coefficient (ICC) and Bland–Altman analysis.

Results

Dmax, as measured on axial slices at baseline and follow-up (FU) MDCTs, was greater than that measured using the orthogonal method (p?=?0.046 for baseline and 0.028 for FU), whereas Dmax measured with the orthogonal method was greater those using all other measurement methods (p-value range: <0.0001–0.03) but anteroposterior diameter (p?=?0.18 baseline and 0.10 FU). The greatest interobserver ICCs were obtained for the orthogonal and transverse methods (0.972) at baseline and for the orthogonal and sagittal MPR images at FU (0.973 and 0.977). Interobserver ICC of the orthogonal method to document AAA progression was greater (ICC?=?0.833) than measurements taken on axial images (ICC?=?0.662–0.780) and single-plane MPR images (0.772–0.817).

Conclusion

AAA Dmax measured on MDCT axial slices overestimates aneurysm size. Diameter as measured by the orthogonal method is more reproducible, especially to document AAA progression.  相似文献   

17.
PURPOSE: The purpose of this study was to evaluate the ability of rotated paddlewheel reformations for the detection of central and peripheral pulmonary embolism (PE) compared to standard axial multi detector CT (MDCT) images. MATERIAL AND METHODS: CT scans of 35 patients with PE were reviewed by three independent readers for the detection of pulmonary emboli using standard axial CT scans and reformatted paddlewheel technique. All images were evaluated in random order. MDCT examinations were performed with a collimation of 1.25 mm, a pitch of six and a reconstruction interval of 0.8mm. For each patient MIP were reformatted by using a paddlewheel arrangement with 5mm slab thickness and 5 degrees rotation. Standard of reference for PE was a consensus reading of the axial images by all three readers. RESULTS: The overall sensitivity for the axial images for the three readers ranged between 91% and 96%; for paddlewheel reformations from 78% to 83%; the specificity for both methods was 98-99%. Inter- and intraobserver agreement was also higher for axial images than for paddlewheel reformations. CONCLUSION: Comparing standard axial MDCT scans and reformatted paddlewheel images no significant difference for the detection of central PE was found, whereas for the detection of peripheral emboli standard axial images showed a significant higher percentage of detecting PE than paddlewheel reformations.  相似文献   

18.
Two axial and coronal section planes are commonly used for a conventional computed tomography diagnosis of the temporal bone. In recent years, sagittal and oblique section planes have been reformatted using high-resolution multiplanar reconstruction (MPR). Detailed three-dimensional (3D) images are also employed. To understand the 3D structure of the small, complicated temporal bone, we compared common angle MPR section planes with 3D images. We also suggest four-section planes, which are optimal for observing the ossicular chain.  相似文献   

19.
The purpose of the study was to evaluate the visualization of the collateral ankle ligaments on multiplanar reconstructions (MPR) based on standard 2D turbo spin-echo images. Coronal and axial T2-weighted turbo spin-echo and MPR angled parallel to the course of the ligaments of 15 asymptomatic and 15 symptomatic ankles were separately analyzed by two musculoskeletal radiologists. Image quality was assessed in the asymptomatic ankles qualitatively. In the symptomatic ankles interobserver agreement and reader confidence was determined for each ligament. On MPR the tibionavicular and calcaneofibular ligaments were more commonly demonstrated on a single image than on standard MR images (reader 1: 13 versus 0, P=0.002; reader 2: 14 versus 1, P=0.001 and reader 1: 13 versus 2, P=0.001; reader 2: 14 versus 0, P<0.001). The tibionavicular ligament was considered to be better delineated on MPR by reader 1 (12 versus 3, P=0.031). In the symptomatic ankles, reader confidence was greater with MPR for all ligaments except for the tibiocalcanear ligament (both readers) and the anterior and posterior talofibular ligaments (for reader 2). Interobserver agreement was increased with MPR for the tibionavicular ligament. Multiplanar reconstructions of 2D turbo spin-echo images improve the visualization of the tibionavicular and calcaneofibular ligaments and strengthen diagnostic confidence for these ligaments.  相似文献   

20.
Jin KN  Lee JM  Kim SH  Shin KS  Lee JY  Han JK  Choi BI 《European radiology》2006,16(10):2284-2291
The purpose of this study was to determine whether multiplanar reconstruction (MPR) images can improve the accuracy of MDCT-based colorectal cancer preoperative staging by receiver-operating characteristic (ROC) analysis. Fifty-five patients with colorectal cancer underwent contrast-enhanced CT colonography using an 8- or 16-row scanner. Two separate interval reviews of the axial MDCT datasets with/without MPR images (coronal and sagittal) were performed independently by two radiologists blinded to both the colonoscopic and histopathologic results. At each review session, the radiologists were asked to determine the colorectal cancer TNM stage within the context of differentiating ≤T3 from T4, N0 from ≥N1 and M0 from M1 using a five-point confidence scale. The radiologists’ performance for staging the colorectal cancer using axial CT datasets with/without MPR images was evaluated using ROC analysis. Sensitivities, specificities and interobserver agreement were assessed. When MPR images were added, significant improvement was achieved by both radiologists for differentiating N0 from ≥N1 in terms of both AZ (0.651 to 0.769; 0.573 to 0.713) and specificity (26.7 to 69.2%; 23.1 to 76.9%) (P<0.05). For T staging, ROC analysis failed to show a significant improvement in terms of differentiating ≤T3 from T4 for either radiologist (P>0.05), but a significant improvement in the specificity (70 to 90%; 80 to 92%) was achieved by one radiologist (P<0.05). In terms of the M staging, a significant improvement in the Az (0.844 to 0.996) was observed for the combined interpretation of the axial and MPR images by one radiologist (P<0.05). Furthermore, substantial or almost perfect interobserver agreement was achieved for all TNM stagings for the combined interpretations (κ=0.641–0.866), whereas only fair to substantial agreement was achieved for the axial images alone (κ=0.337-0.707). In conclusion, the combined interpretation of the axial and MPR MDCT images significantly improved the local staging of colorectal cancer compared with assessments based on axial images alone.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏