首页 | 本学科首页   官方微博 | 高级检索  
相似文献
 共查询到20条相似文献,搜索用时 31 毫秒
1.
PurposeTo evaluate the effect of heart rate, heart rate variability on dual-source computed tomography image quality performed without the use of B blockers and to assess diagnostic accuracy of dual-source CT (using adaptive electrocardiographic pulsing) for coronary artery stenosis, by using invasive coronary angiography as the reference standard.Materials and methodsPatients were studied without β-blocker pre-medication. Unenhanced CT and CT coronary angiography with adaptive ECG pulsing were performed using DSCT (DEFINITION, Siemens Medical Solutions, Forchheim, Germany). A contrast-enhanced volume dataset was acquired (two tubes, 120 kV, 400 mAs/rot, collimation 64 × 0.6 mm). Fifty-one patients (11 women, 40 men; mean age, 60.5 years ± 10 [standard deviation]) known to have or suspected of having coronary artery disease underwent dual-source CT and invasive coronary angiography. Accuracy of dual-source CT in depiction or exclusion of significant stenosis (?50%) was evaluated on a per-segment and per-patient basis. Effects of heart rate, heart rate variability were assessed. Patients were divided in three HRF groups: low, intermediate, and high (?65, 66–79, and ?80 beats/min, respectively), and four HRV groups given mean inter beat difference (IBD) during CT coronary angiography: normal, minor, moderate, and severe (IBDs of 0–1, 2–3, 4–10, and >10, respectively). The diagnostic performance was presented as sensitivity, specificity, positive predictive values, and negative predictive values validated against invasive coronary angiography (?50% lumen diameter reduction).ResultsGood image quality was achieved in 98% of patients without the use of B blockers and no significant differences in image quality were found among HRF and HRV groups. Twenty-three patients were examined having a heart rate ?65 beats/min, image quality was sufficient for diagnosis in 281 of 312 coronary segments (92%), whereas in 28 patients with a heart rate <65 beats/min, the image quality was sufficient for diagnosis in 387 of 388 coronary segments (100%). On a per-patient basis, 93% of patients (?65 beats/min) and 100% of patients (<65 beats/min) were considered evaluable. None of these differences were statistically significant. Similarly, no difference in diagnostic accuracy was found in per-vessel and -segment analyses.ConclusionIn 51 patients studied without β-blocker pre-medication, the overall image quality of dual-source CT coronary angiography is sufficient for diagnosis within a wide range of mean heart rates and variability of heart rates. Only heart rates that are both high and variable significantly deteriorate image quality, but the quality remains adequate for diagnosis.  相似文献   

2.
PurposeTo analyze long-term outcomes in patients bridged/downstaged to orthotopic liver transplantation (OLT) by transarterial chemoembolization (TACE) or yttrium-90 radioembolization (Y90) for hepatocellular carcinoma (HCC).Methods172 HCC patients who underwent OLT after being treated with transarterial liver-directed therapies (LDTs) (Y90: 93; TACE: 79) were identified. Pre-LDT and pre-OLT clinical/imaging/laboratory characteristics including United Network for Organ Sharing (UNOS) staging and alpha-fetoprotein values (AFP) were tabulated. Post-OLT HCC recurrence was assessed by imaging follow-up per standard of care. Recurrence-free (RFS) and overall survival (OS) were calculated. Uni/multivariate and sub-stratification analyses were performed.ResultsTime-to-OLT was longer in the Y90 group (Y90: 6.5 months; TACE: 4.8 months; p = 0.02). With a median post-OLT follow-up of 26.1 months (IQR: 11.1–49.7), tumor recurrence was found in 6/79 (8%) TACE and 8/93 (9%) Y90 patients. Time-to-recurrence was 26.6 (CI: 7.0–49.5) and 15.9 months (CI: 7.8–46.8) for TACE and Y90, respectively (p = 0.48). RFS (Y90: 79 months; TACE: 77 months; p = 0.84) and OS (Y90: 57% alive at 100 months; TACE: 84.2 months; p = 0.57) were similar. 54/155 patients (Y90: 29; TACE: 25) were downstaged to UNOS T2 or less. RFS hazard ratios for patients downstaged to ≤T2 versus those that were not were 0.6 (CI: 0.33–1.1) and 1.7 (CI: 0.9–3.1) respectively (p = 0.13). 17/155 patients (Y90: 8; TACE: 9) that were >T2 were downstaged to UNOS T2 or less (within transplant criteria). Distribution (unilobar/bilobar), AFP, and pre-transplant UNOS stage affected RFS on univariate analyses.ConclusionDespite longer time-to-OLT for Y90 patients, post-OLT outcomes were similar between patients bridged or downstaged by TACE or Y90. A trend towards improved RFS for downstaged patients was identified.  相似文献   

3.
PurposeThis prospective clinical study examined standard wrist magnetic resonance imaging (MRI) examinations and the incremental value of computed tomography (CT) in the diagnosis of Kienböck's disease (KD) with regard to reliability and precision in the different diagnostic steps during diagnostic work-up.Materials and methodsSixty-four consecutive patients referred between January 2009 and January 2014 with positive initial suspicion of KD according to external standard wrist MRI were prospectively included (step one). Institutional review board approval was obtained. Clinical examination by two handsurgeons were followed by wrist radiographs (step two), ultrathin-section CT, and 3 T contrast-enhanced MRI (step three). Final diagnosis was established in a consensus conference involving all examiners and all examinations results available from step three.ResultsIn 12/64 patients, initial suspicion was discarded at step two and in 34/64 patients, the initial suspicion of KD was finally discarded at step three. The final external MRI positive predictive value was 47%. The most common differential diagnoses at step three were intraosseous cysts (n = 15), lunate pseudarthrosis (n = 13), and ulnar impaction syndrome (n = 5). A correlation between radiograph-based diagnoses (step two) with final diagnosis (step three) showed that initial suspicion of stage I KD had the lowest sensitivity for correct diagnosis (2/11). Technical factors associated with a false positive external MRI KD diagnosis were not found.ConclusionStandard wrist MRI should be complemented with thin-section CT, and interdisciplinary interpretation of images and clinical data, to increase diagnostic accuracy in patients with suspected KD.  相似文献   

4.
PurposeTo determine the value of multislice CT coronary artery calcification (CAC) scoring in the prediction of future cardiac events in known chronic kidney disease (CKD) patients using conventional coronary angiography as the standard reference.Patients and methodsFifty-eight patients with CKD on hemodialysis underwent CT CAC scoring using multislice scanner and conventional coronary angiography. Results of CAC scoring were compared to the findings of conventional coronary angiography.ResultsMean CAC scoring in patients with significant coronary arteries stenotic lesions was higher than in patients with no significant coronary arteries stenotic lesions with significant difference (P < 0.001).Mean patient CAC scoring was strongly correlated with the number of coronary arteries with significant stenotic lesions (r = 0.910).ConclusionCT CAC scoring is a non-invasive technique which can be used in the evaluation and follow up of CKD patients’ coronary arteries without the use of contrast medium reducing the number of invasive coronary angiography needed.  相似文献   

5.
PurposeTo investigate the feasibility of perfusion-CT (p-CT) measurements in quantitative assessment of hemodynamic changes related to sorafenib in patients with advanced hepatocellular carcinoma (HCC).Materials and methodsTwenty-two patients with advanced HCC underwent p-CT study (256-MDCT scanner) before and 2 months after sorafenib administration. Dedicated perfusion software generated a quantitative map of arterial and portal perfusion and calculated the following perfusion parameters in target liver lesion: hepatic perfusion (HP), time-to-peak (TTP), blood volume (BV), arterial perfusion (AP), and hepatic perfusion index (HPI). After the follow-up scan, patients were categorized as responders and non-responders, according to mRECIST. Perfusion values were analyzed and compared in HCC lesions and in the cirrhotic parenchyma (n = 22), such as between baseline and follow-up in progressors and non-progressors.ResultsBefore treatment, all mean perfusion values were significantly higher in HCC lesions than in the cirrhotic parenchyma (HP 47.8 ± 17.2 vs 13.3 ± 6.3 mL/s per 100 g; AP 47.9 ± 18.1 vs 12.9 ± 10.7 mL/s; p < 0.001). The group that responded to sorafenib (n = 17) showed a significant reduction of values in HCC target lesions after therapy (HP 29.2 ± 23.3 vs 48.1 ± 15.1; AP 29.4 ± 24.6 vs 49.2 ± 17.4; p < 0.01), in comparison with the non-responder group (n = 5) that demonstrated no significant variation before and after treatment of HP (46.9 ± 25.1 vs 46.7 ± 24.1) and AP (43.4 ± 21.7 vs 43.5 ± 24.6). Among the responder group, HP percentage variation (Δ) in target lesions, during treatment, showed a significantly different (p = 0.04) ΔHP in the group with complete response (79%) compared to the group with partial response or stable disease (16%).Conclusionsp-CT technique can be used for HCC quantitative assessment of changes related to anti-angiogenic therapy. Identification of response predictors might help clinicians in selection of patients who may benefit from targeted-therapy allowing for optimization of individualized treatment.  相似文献   

6.
PurposeTo quantify respiration-induced deformations of the superior mesenteric artery (SMA), left renal artery (LRA), and right renal artery (RRA) in patients with small abdominal aortic aneurysms (AAAs).Materials and MethodsSixteen men with AAAs (age 73 y ± 7) were imaged with contrast-enhanced magnetic resonance angiography during inspiratory and expiratory breath-holds. Centerline paths of the aorta and visceral arteries were acquired by geometric modeling and segmentation techniques. Vessel translations and changes in branching angle and curvature resulting from respiration were computed from centerline paths.ResultsWith expiration, the SMA, LRA, and RRA bifurcation points translated superiorly by 12.4 mm ± 9.5, 14.5 mm ± 8.8, and 12.7 mm ± 6.4 (P < .001), and posteriorly by 2.2 mm ± 2.7, 4.9 mm ± 4.2, and 5.6 mm ± 3.9 (P < .05), respectively, and the SMA translated rightward by 3.9 mm ± 4.9 (P < .01). With expiration, the SMA, LRA, and RRA angled upward by 9.7° ± 6.4, 7.5° ± 7.8, and 4.9° ± 5.3, respectively (P < .005). With expiration, mean curvature increased by 0.02 mm?1 ± 0.01, 0.01 mm?1 ± 0.01, and 0.01 mm?1 ± 0.01 in the SMA, LRA, and RRA, respectively (P < .05). For inspiration and expiration, RRA curvature was greater than in other vessels (P < .025).ConclusionsWith expiration, the SMA, LRA, and RRA translated superiorly and posteriorly as a result of diaphragmatic motion, inducing upward angling of vessel branches and increased curvature. In addition, the SMA exhibited rightward translation with expiration. The RRA was significantly more tortuous, but deformed less than the other vessels during respiration.  相似文献   

7.
《Radiography》2018,24(2):e31-e36
IntroductionIncreasing pressure in the clinic requires a more standardized approach to radiostereometric analysis (RSA) imaging. The aim of this study was to investigate whether implementation of personalized RSA patient protocols could increase image quality and decrease examination time and the number of exposure repetitions.MethodsForty patients undergoing primary total hip arthroplasty were equally randomized to either a case or a control group. Radiographers in the case group were assisted by personalized patient protocols containing information about each patient's post-operative RSA imaging. Radiographers in the control group used a standard RSA protocol.ResultsAt three months, radiographers in the case group significantly reduced (p < 0.001) the number of exposures by 1.6, examination time with 19.2 min, and distance between centrum of prosthesis and centrum of calibration field with 34.1 mm when compared to post-operative (baseline) results. At twelve months, the case group significantly reduced (p < 0.001) number of exposures by two, examination time with 22.5 min, and centrum of prosthesis to centrum of calibration field distance with 43.1 mm when compared to baseline results. No significant improvements were found in the control group at any time point.ConclusionThere is strong evidence that personalized RSA patient protocols have a positive effect on image quality and radiation dose savings. Implementation of personal patient protocols as a RSA standard will contribute to the reduction of examination time, thus ensuring a cost benefit for department and patient safety.  相似文献   

8.
BackgroundRecent studies demonstrated a significant improvement in the diagnostic performance of coronary CT angiography (CCTA) for the evaluation of in-stent restenosis (ISR). However, coronary stent assessment is still challenging, especially because of beam-hardening artifacts due to metallic stent struts and high atherosclerotic burden of non-stented segments. Adenosine-stress myocardial perfusion assessed by CT (CTP) recently demonstrated to be a feasible and accurate tool for evaluating the functional significance of coronary stenoses in patients with suspected coronary artery disease (CAD). Yet, scarce data are available on the performance of CTP in patients with previous stent implantation.Aim of the studyWe aim to assess the diagnostic performance of CCTA alone, CTP alone and CCTA plus CTP performed with a new scanner generation using quantitative invasive coronary angiography (ICA) and invasive fractional flow reserve (FFR) as standard of reference.MethodsWe will enroll 300 consecutive patients with previous stent implantation, referred for non-emergent and clinically indicated invasive coronary angiography (ICA) due to suspected ISR or progression of CAD in native coronary segments. All patients will be subjected to stress myocardial CTP and a rest CCTA. The first 150 subjects will undergo static CTP scan, while the following 150 patients will undergo dynamic CTP scan. Measurement of invasive FFR will be performed during ICA when clinically indicated.ResultsThe primary study end points will be: 1) assessment of the diagnostic performance (diagnostic rate, sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy) of CCTA, CTP, combined CCTA-CTP and concordant CCTA-CTP vs. ICA as standard of reference in a territory-based and patient-based analysis; 2) assessment of sensitivity, specificity, positive predictive value, negative predictive value and diagnostic accuracy of CCTA, CTP, combined CCTA-CTP and concordant CCTA-CTP vs. invasive FFR as standard of reference in a territory-based analysis.ConclusionsThe ADVANTAGE study aims to provide an answer to the intriguing question whether the combined anatomical and functional assessment with CCTA plus CTP may have higher diagnostic performance as compared to CCTA alone in identifying stented patients with significant ISR or CAD progression.  相似文献   

9.
《Radiography》2016,22(4):e228-e232
IntroductionZygomatic fractures can be diagnosed with either computed tomography (CT) or direct digital radiography (DR). The aim of the present study was to assess the effect of CT dose reduction on the preference for facial CT versus DR for accurate diagnosis of isolated zygomatic fractures.Materials and methodsEight zygomatic fractures were inflicted on four human cadavers with a free fall impactor technique. The cadavers were scanned using eight CT protocols, which were identical except for a systematic decrease in radiation dose per protocol, and one DR protocol. Single axial CT images were displayed alongside a DR image of the same fracture creating a total of 64 dual images for comparison. A total of 54 observers, including radiologists, radiographers and oral and maxillofacial surgeons, made a forced choice for either CT or DR.ResultsForty out of 54 observers (74%) preferred CT over DR (all with P < 0.05). Preference for CT was maintained even when radiation dose reduced from 147.4 μSv to 46.4 μSv (DR dose was 6.9 μSv). Only a single out of all raters preferred DR (P = 0.0003). The remaining 13 observers had no significant preference.ConclusionThis study demonstrates that preference for axial CT over DR is not affected by substantial (∼70%) CT dose reduction for the assessment of zygomatico-orbital fractures.  相似文献   

10.
《Radiography》2016,22(2):152-160
ObjectivesTo compare the diagnostic information in detection and assessment of knee pathology from knee radiographs using either the PA standing with partial flexion projection or AP fully extended standing projection.MethodA set of 32 knee radiographs was retrospectively compiled from 16 adult patients imaged using both projections over a 2-year period (PA: n = 16 and AP: n = 16). Repeat radiographs (n = 6) were added to the image set facilitating inter and intra observer reliability. Image evaluation was performed by 5 orthopaedic surgeons performing Absolute Visual Grading Analysis assessing image quality based on 6 anatomical image quality criteria specifically developed to evaluate and compare the two projections. The resulting image quality scores were analysed using Visual Grading Characteristics.ResultsImage quality scores were higher for the PA projection but variation between the two projections was not significant (p > 0.05). The PA projection was significantly (p < 0.05) better in the visualization of 2 anatomical image quality criteria involving the joint space width and tibial spines.ConclusionBoth projections can be used for general evaluation of the knee joint, however the PA partial flexion projection is preferred for the investigation of specific knee pathology. Recommendations for minimizing variations in radiographic positioning technique are also highlighted.  相似文献   

11.
PurposeTo assess the feasibility and diagnostic performance of dynamic volumetric computed tomography (CT) angiography with large-area detectors in the detection and classification of endoleaks after endovascular aneurysm repair (EVAR).Materials and MethodsLow-dose dynamic volumetric CT angiography performed with the patient in Fowler position was used to scan the entire stent graft with a 16-cm-area detector during the first follow-up examination after EVAR. There were 39 consecutive patients (36 men and 3 women; mean age, 74 y ± 8.7) examined with approximately 14–20 intermittent scans (temporal resolution, 2 s; scan range, 160 mm). The effective radiation dose, image quality, interobserver and intraobserver agreement for endoleak detection, and time delay between peak enhancement of the aorta and endoleaks were evaluated.ResultsAll examinations with the patient in Fowler position enabled the entire stent graft to be scanned and were rated as diagnostic. The mean effective radiation dose was 13.1 mSv. Endoleaks were detected in eight patients (type Ia, n = 1; type II, n = 6; type III, n = 1). Interobserver agreement (κ = 0.794) and intraobserver agreement (κ = 1.00) for detection of endoleaks were excellent. The mean time delay between peak enhancement of the aorta and the endoleaks was significantly less for type I/III endoleaks (2.0 s ± 0) compared with type II endoleaks (5.3 s ± 1.0; P < .001).ConclusionsLow-dose dynamic volumetric CT angiography performed with the patient in Fowler position is feasible after EVAR. Dynamic information, including cine imaging, the timing of peak enhancement, and the Hounsfield units index, is useful in detecting and classifying endoleaks.  相似文献   

12.
PurposeTo measure and compare individual staff radiation dose levels during interventional radiologic (IR) procedures with and without real-time feedback to evaluate whether it has any impact on staff radiation dose.Materials and MethodsA prospective trial was performed in which individuals filling five different staff roles wore radiation dosimeters during all IR procedures during two phases: a 12-week “closed” phase (measurements recorded but display was off, so no feedback was provided) and a 17-week “open” phase (display was on and provided real-time feedback). Radiation dose rates were recorded and compared by Mann–Whitney U test.ResultsThere was no significant difference in median procedure time, fluoroscopy time, or patient dose (dose–area product normalized to fluoroscopy time) between the two phases. Overall, the median staff dose was lower in the open phase (0.56 µSv/min of fluoroscopy time) than in the closed phase (3.01 µSv/min; P < .05). The IR attending physician dose decreased significantly for procedures for which the physicians were close to the patient, but not for ones for which they were far away.ConclusionsA radiation dose monitoring system that provides real-time feedback to the interventional staff can significantly reduce radiation exposure to the primary operator, most likely by increasing staff compliance with use of radiation protection equipment and dose reduction techniques.  相似文献   

13.
PurposeTo compare standard coil embolization versus the use of an antireflux microcatheter (ARM) in patients undergoing planning angiography before selective internal radiation therapy (SIRT).Materials and MethodsA prospective, single-center trial was performed in which 30 patients were randomly assigned to undergo SIRT with coil embolization or the use of an ARM. The coil group underwent detachable coil embolization of nontarget vessels, and the ARM group underwent infusion of macroaggregated albumin with use of an ARM system, without coil embolization. Single-photon emission computed tomography (CT)/CT was then performed to assess for nontarget distribution. The primary endpoint was fluoroscopy time during planning angiography. Secondary endpoints included deployment time, total procedure time, radiation dose–area product, contrast agent used, and adverse events. Endpoints were evaluated during planning angiography and SIRT.ResultsOver a 9-month period, 30 consecutive patients were randomized at a 1:1 ratio between coil embolization and ARM groups. Technical success rates were 100% in both groups. Mean fluoroscopy time was significantly reduced in the ARM group versus the coil embolization group (1.8 min [range, 0.4–4.9 min] vs 6.0 min [range, 1.9–15.7 min]; P = .002). The planning procedure time (P < .001), deployment time (P < .001), dose–area product (P = .04), and amount of contrast agent used (P < .001) were also significantly less in the ARM group than in the coil embolization group. No nontarget distribution was detected in either group. There was no difference between groups in dose delivered on the day of SIRT (P = .71). There were no major or minor adverse events at 30 days.ConclusionsThe use of an ARM during planning angiography can significantly reduce fluoroscopy time, procedure time, and radiation dose.  相似文献   

14.
BackgroundCoronary computed tomography angiography (CCTA) not only provides information regarding luminal stenoses but also allows for visualization of mural atheromatous changes (coronary plaques).ObjectiveWe sought to elucidate whether plaques seen on CCTA enable prediction of 2-year outcomes in patients with suspected and known coronary artery disease (CAD).MethodsOf 3015 patients who underwent CCTA, the images and 2-year clinical courses of 2802 patients were independently analyzed. The primary endpoint was the composite of all-cause death and acute coronary syndrome.ResultsDuring the 2-year observation period, 49 (1.7%) patients developed the primary outcome. The 2-year rates of the primary outcome in the normal (n = 515, no mural lesions), calcium (n = 654, calcified lesion alone), and plaque groups (n = 1633, presence of noncalcified or partially calcified plaques) were 0.2%, 2.0%, and 2.1%, respectively (P = 0.0028). Adverse plaque features such as low attenuation, positive remodeling, spotty calcification, and the napkin-ring sign (low-attenuation core with a higher-attenuation rim) were assessed by an independent core laboratory. Stepwise multivariate Cox proportional hazard analysis showed that a plaque with two or more characteristics (adjusted hazard ratio, 1.98; 95% confidence interval, 1.09–3.60; P = 0.0254), age of ≥67 years (mean), statin treatment after CCTA, and obstructive stenosis remained independent predictors of the primary outcome.ConclusionsPlaque imaging in CCTA has predictive value for the 2-year outcome and is a useful identifier for high-risk patients among those with known and suspected CAD.  相似文献   

15.
PurposeTo assess the radiation exposure to individuals coming from patients after treatment with holmium-166 (166Ho) microspheres.Materials and MethodsHolmium-166 radioembolization (RE) with escalating whole-liver doses of 20 Gy, 40 Gy, 60 Gy, and 80 Gy was administered to 15 patients. Exposure rates (μSv/h) from patients were measured at 1.0 m distance from a lateral and frontal position at 0, 3, 6, 24, and 48 hours after infusion. The total effective dose equivalent (TEDE) to a maximally exposed contact was calculated in accordance with guidelines of the U.S. Nuclear Regulatory Commission (NRC). Results were extrapolated to a whole-liver dose of 60 Gy used in future treatments.ResultsThe median exposure rate at discharge, 48 hours after infusion, measured from a lateral position was 26 μSv/h (range, 7–45 μSv/h). Extrapolated to a whole-liver dose of 60 Gy, none of the exposure rates for the NRC contact scenario, at any time, frontal or lateral, would lead to a TEDE > 5 mSv; all patients may be released directly after treatment. Release after 6 hours is possible without contact restrictions for patients who received up to 7 GBq.ConclusionsThe TEDE to a contact of patients treated with 166Ho RE would not exceed the NRC limit of 5 mSv. Contact restrictions 6 hours after treatment are unnecessary for infused activities < 7 GBq.  相似文献   

16.
《Radiography》2017,23(4):e80-e86
IntroductionThe purpose of this study was to design and evaluate a radiostereometric analysis (RSA) program aimed at radiographers in order to increase their cognitive and practical skills, thereby increasing image quality and minimizing exposure repetition.Methods and materialsTwenty radiographers were randomized into two identically sized study groups. Training consisted of a theoretical and practical workshop using a phantom. Tests were performed to compare the effect of training to nontraining, and the effect of time duration on the maintenance of RSA skills. The effect of training was measured by a written test and three defined parameters influencing image quality.ResultsGroup A reduced significantly (p < 0.001) by 31.3 mm (21–31%) the distance between the centrum of the prosthesis (CP) and the centrum of the calibration field (CCF) and increased the number of beads (NB) visible by 3.6 (out of 18). A further significant reduction of 5.1 mm (p = 0.023), 1.0 bead more (p < 0.001) and a 2.1 (p = 0.022) point better rotation of the prosthesis (RP) was registered two months later. Group B was tested twice without training and no significant improvement was registered. One month after training group B had experienced overall significant improvement on a par with group A.ConclusionIt is realistic to implement an RSA X-ray training program where radiographers significantly improve their theoretical and practical skills in centering the CP closer to the CCF, NB and RP. A duration of up to two months after training does not influence the quality of participants' performance.  相似文献   

17.
PurposeTo evaluate the diagnostic performance of dual-energy (DE) computed tomography (CT) after thoracic endovascular aortic repair (TEVAR) of type B dissection, and to investigate the value of late delayed (LD) acquisition in endoleak detection and false lumen patency assessment.Materials and MethodsTwenty-four patients with TEVAR for type B dissection underwent 53 tripe-phase CT examinations. Single-source unenhanced acquisition was followed by single-source arterial-phase and DE LD phase (300-s delay) imaging. Virtual noncontrast images were generated from DE acquisition. Two blinded radiologists retrospectively evaluated the cases in three reading sessions: session A (triphasic protocol), session B (virtual noncontrast and arterial phase), and session C (virtual noncontrast and arterial and LD phases). Endoleak detection accuracy during sessions B and C compared with session A (reference standard) was investigated. False lumen patency was assessed. Effective radiation dose was calculated.ResultsSession A revealed 37 endoleaks in 30 of 53 studies (56.6%). Session B revealed 31 of the 37 endoleaks, with one false-positive case, 83.8% sensitivity, 95.8% specificity, 79.3% negative predictive value, and 96.9% positive predictive value. Session C correctly depicted all 37 endoleaks, with one false-positive case, 100% sensitivity, 95.8% specificity, 100% negative predictive value, and 97.4% positive predictive value. Underestimation of false lumen patency was found in session B (P = .013). Virtual noncontrast imaging resulted in 17% radiation exposure reduction.ConclusionsVirtual noncontrast imaging can replace standard unenhanced images in follow-up after TEVAR of type B dissection, thus reducing radiation dose. Delayed-phase imaging is valuable in low-flow endoleaks detection and false lumen patency assessment.  相似文献   

18.
《Radiography》2018,24(2):e37-e43
IntroductionProducing x-ray images for radiostereometric analysis (RSA) is a demanding technique. Suboptimal examinations result in a high percentage of exposure repetition. The aim of this pilot study was to use an experiential training approach to sharpen the skills of radiographers in acquiring images of an optimal quality.MethodsA controlled trial using action research strategy was used. The study entailed a two phased approach. Radiographers were purposefully recruited and trained to perform the required investigations. Each phase included 12 examinations of a total knee arthroplasty phantom followed by 10 patient examinations. The quality of all x-ray images performed during the two phases was characterized by measuring the number of visible beads, the center position of the prosthesis (CP) compared to the center of calibration field (CCF). The number of re-exposures used to obtain a usable image during patient examinations was also recorded.ResultsThe radiographers undergoing the training resulted in a significant improvement in the quality of images produced and visualization of the beads. That is, the ability to move the CP on average 36.1 mm closer to the CCF (p < 0.001), the number of visible beads increased by 3.1 (p < 0.001) and radiographers needed 2.1–2.9 exposures less to obtain RSA images of sufficient qualities during patient examinations in phase 2 (p < 0.001).ConclusionThis study illustrates the value of experiential method of teaching and learning with minimal compromise on patient safety but a significant contribution in terms of establishing quality of RSA images.  相似文献   

19.
PurposeTo compare in a prospective noninferiority study optical coherence tomography (OCT) and intravascular ultrasound (IVUS) in popliteal and infrapopliteal vessels.Materials and MethodsOCT and IVUS images of 112 popliteal and infrapopliteal arterial segments were prospectively obtained from 16 patients with peripheral arterial occlusive disease. Three observers evaluated the corresponding OCT and IVUS images for image quality, artifact frequency, discriminability of vessel wall layers, and plaque composition. Measurements of the lumen, vessel, and plaque areas were compared for both modalities.ResultsThe intrareader and interreader reproducibility of plaque tissue discrimination (0.88 vs 0.75), overall image quality, and vessel wall layer discriminability were significantly higher for OCT (all P < .001). Artifact frequency was higher in OCT, constraining the imaging of the tibioperoneal trunk. The results of measurements of the lumen and vessel area were comparable for both modalities (correlation > 0.9, P < .001). Plaque area measurements differed (correlation 0.8, P < .01) because OCT underestimated it. The OCT procedure caused vessel spasms in two patients.ConclusionsOCT imaging of infrapopliteal arteries is feasible and safe and provides high image quality. It enables an accurate assessment of vessel lumen, wall, and plaque. Compared with IVUS, OCT images provide excellent image quality and superior visualization of vessel wall layers and different plaque components. The penetration depth of OCT restricts its use to suitable vessel regions.  相似文献   

20.
《Radiography》2018,24(4):e75-e84
IntroductionUltrasound (US) has an important role in musculoskeletal (MSK) evaluation, allowing the study of muscle morphology and function. Muscle thickness (MT) and muscle echo-intensity (EI) are two important parameters that may quantify muscle structural adaptations to a variety of stimuli. The aim was to explore the potential of quantitative US imaging for assessing the adaptations and responses of the muscle tissue to increased contractile activity using B-mode US. This study was centred on the quadriceps femoris muscle contractile activity on MT and EI.Methods and materialsTwenty-eight young male adults participated in the study, divided in a control group and two training groups performing concentric or eccentric strength training, respectively. The effect of a 15-week strength program was studied on MT and EI in several regions of the heads of the quadriceps femoris using B-mode US. All images acquisitions and measurements were done by the same experience sonographer.ResultsStrength training resulted in an increase of MT at all muscles and sites (p < 0.05), except the VM. Strength training failed in changing EI in most of the quadriceps femoris, except in the VI and some regions of the VL. No statistically significant differences were observed in our quantitative US parameters between concentric and eccentric training (p > 0.05).ConclusionThese results emphasise the value of MT as a quantifiable muscle US method for evaluating muscle adaptation to exercise training. However, the inconsistency of the EI values indicates that more studies are needed to develop it as an accurate diagnostic tool.  相似文献   

设为首页 | 免责声明 | 关于勤云 | 加入收藏

Copyright©北京勤云科技发展有限公司  京ICP备09084417号